NORTH CAROLINA
Environmental Quality
August 8, 2019
Subject: Compliance Evaluation Inspection
Diamond Head Subdivision WWTP
NPDES Permit No. NCO074772
Iredell County
Enclosed is a copy of the Compliance Evaluation Inspection Report for the inspection conducted at the subject facility on
August 1, 2019, by Mr. Wes Bell of this Office. Please inform the facility's Operator -in -Responsible Charge (ORC) of our
findings by forwarding a copy of the enclosed report.
The report should be self-explanatory; however, should you have any questions concerning this report, please do
not hesitate to contact Mr. Bell at (704) 235-2192 or at wes.bell@ncdenr.gov.
Sincerely,
Docu Signed by:
4d tw H P;,Uf .
F161FB69A2D84A3...
for W. Corey Basinger, Regional Supervisor
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ
Enclosure:
Inspection Report
D Q
� North Carolina Department of Environmental Quality I Division of Water Resources
Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115
NORTH CAROLINA
Da"MoM a enWmn�bl mwnq 704,663.1699
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN I 2 IF I 3 I NCO074772 111 12 I 19/08/01 I17 18 I S i 19 i G i 201 I
211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I f6
Inspection
Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved -------------------
67
2.0 70 Id I 71 [„ I 72 I I 73 I I 74 75I I I I I I I I80
I —I I� I I
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES oermit Number)
09:12AM 19/08/01
18/05/01
Diamond Head WWTP
NCSR 1109
Exit Time/Date
Permit Expiration Date
Mooresville NC 28115
10:35AM 19/08/01
20/03/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Dana A Bixby/ORC/704-507-3359/
Dustin Joseph DillardH828-216-6459 /
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Shannon V Becker,202 Mackenan Ct Cary NC 27511/President/919-653-5570/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Records/Reports
Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
DocuSigned by: 8�8/2019
Wes Bell MRO WQ//704-663-1699 Ext.2192/
e4, BX
EW-iA61696D90CC3437
...
RP�!'�I�4b�it Uer Agency/Office/Phone and Fax Numbers Date
Signature of ManaCA44"
Andrew Pitne " P O WQ//704-663-1699 Ext.21 8.8.19
1`161 FB69AMUA3...
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
NPDES yr/mo/day Inspection Type
NCO074772 I11 121 19/08/01 117 18 JCJ
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page#
Permit: NCO074772 Owner - Facility: Diamond Head WWTP
Inspection Date: 08/01/2019 Inspection Type: Compliance Evaluation
Permit
Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
❑
❑
0
❑
application?
Is the facility as described in the permit?
0
❑
❑
❑
# Are there any special conditions for the permit?
0
❑
❑
❑
Is access to the plant site restricted to the general public?
0
❑
❑
❑
Is the inspector granted access to all areas for inspection?
0
❑
❑
❑
Comment: The Division issued Dermit modifications (PM) on 7/14/17. 4/12/18 and 5/10/18 and a Dermit
correction change on 8/31/17. The modifications include the following: additional effluent
parameters/limits due to the introduction of additional wastewater (uranium filter backwash)
generated from AQUA -owned wells producing potable water (7/14/17 PM); extension of the
effluent limit deadline for total copper to 4/1/20 (4/12/18 PM); extension of effluent limit
deadline for total chloride, total fluoride, total zinc, and WET Testing (as monitor only) to
4/1/20 (5/10/18 PM). The units of measurement for total chloride were changed from ug/L to
mq/L in the 8/31/17 permit correction change.
The last compliance evaluation inspection by DWR staff was performed on 12/14/16.
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator
on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility classification?
Is a copy of the current NPDES permit available on site?
Yes No NA NE
❑
❑
❑
❑
❑
❑
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
Page# 3
Permit: NCO074772
Inspection Date: 08/01/2019
Owner - Facility: Diamond Head WWTP
Inspection Type: Compliance Evaluation
Record Keeping Yes No NA NE
Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑
Comment: The records reviewed during the inspection were organized and well maintained. Discharge
Monitoring Reports (eDMRs) were reviewed for the period July 2018 through June 2019. No
effluent limit violations were reported and all monitoring frequencies were correct.
Laboratory
Yes No NA NE
Are field parameters performed by certified personnel or laboratory?
0
❑
❑
❑
Are all other parameters(excluding field parameters) performed by a certified lab?
0
❑
❑
❑
# Is the facility using a contract lab?
0
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
0
❑
❑
❑
Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
❑
❑
0
❑
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
❑
❑
0
❑
Comment: On -site field analvses (dissolved oxvaen. DR temperature. total residual chlorine) are
performed under Aqua NC's laboratory certification #5035. Water Tech Labs (all permit
parameters except field and toxicity) and R&A Labs (toxicity) have also been contracted to
provide analytical support.
The ORC was not performing post -analysis calibration checks on the dissolved oxygen and
total residual chlorine meters following field analyses at multiple sites. Post -analysis
calibration checks must be performed in accordance with the NC Wastewater/Groundwater
laboratory certification approved procedures for the analyses of dissolved oxygen and total
residual chlorine.
The ORC and staff must ensure to report all effluent total residual chlorine values down to
the lowest standard verified on the total residual chlorine meter (annual curve verification).
Effluent Sampling
Yes No NA NE
Is composite sampling flow proportional?
0
❑
❑
❑
Is sample collected below all treatment units?
0
❑
❑
❑
Is proper volume collected?
0
❑
❑
❑
Is the tubing clean?
0
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
M
❑
❑
❑
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
0
❑
❑
❑
representative)?
Comment: The subiect Dermit reauires composite and arab effluent samples. The sampler
temperature was less than five degrees Celsius and collecting 320 ml. aliquots at the time of
the inspection. The ORC must ensure to document the monthly aliquot verifications.
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Page# 4
Permit: NCO074772 Owner - Facility: Diamond Head WWTP
Inspection Date: 08/01/2019 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: The wastewater treatment facilitv armeared to be DroDerly operated and well maintained
Process control measurements were being documented and maintained on -site.
The facility's telemetry -type alarm system functioned properly during the on -site test.
The facility has been equipped with a 1,000 gallon tank for the collection of the uranium filter
backwash water generated from Agua's potable well systems. One 800 gallon load has
been received (April 2019) and the wastewater was combined with the influent via metering
system. This Office recommends the installation of a secondary containment system
around the storage tank to contain any potential spills, leakages, etc.
Equalization Basins
Yes No NA NE
Is the basin aerated?
0
❑
❑
❑
Is the basin free of bypass lines or structures to the natural environment?
0
❑
❑
❑
Is the basin free of excessive grease?
0
❑
❑
❑
Are all pumps present?
0
❑
❑
❑
Are all pumps operable?
0
❑
❑
❑
Are float controls operable?
0
❑
❑
❑
Are audible and visual alarms operable?
0
❑
❑
❑
# Is basin size/volume adequate?
0
❑
❑
❑
Comment:
Bar Screens Yes No NA NE
Type of bar screen
a.Manual
b.Mechanical
❑
Are the bars adequately screening debris?
0
❑
❑
❑
Is the screen free of excessive debris?
0
❑
❑
❑
Is disposal of screening in compliance?
0
❑
❑
❑
Is the unit in good condition?
0
❑
❑
❑
Comment: Screenings are transported to the Hwy.
150 WWTP and ultimately disposed at the County
Landfill by a contracted company.
Aeration Basins
Mode of operation
Type of aeration system
Yes No NA NE
Ext. Air
Diffused
Page# 5
Permit: NCO074772
Inspection Date: 08/01/2019
Aeration Basins
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Is the DO level acceptable?(1.0 to 3.0 mg/1)
Owner - Facility: Diamond Head WWTP
Inspection Type: Compliance Evaluation
Yes No NA NE
■
❑
❑
❑
❑
❑
■
❑
■
❑
❑
❑
❑
❑
❑
•
❑
❑
❑
•
❑
❑
❑
❑
❑
■
❑
Comment: Soda ash is added on an as -needed basis to maintain appropriate
alkalinity/pH levels.
The
30-minute settleability test performed during the inspection was 700 ml/L with a clear
supernate.
Secondary Clarifier
Yes No NA NE
Is the clarifier free of black and odorous wastewater?
0
❑
❑
❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
0
❑
❑
❑
Are weirs level?
0
❑
❑
❑
Is the site free of weir blockage?
0
❑
❑
❑
Is the site free of evidence of short-circuiting?
0
❑
❑
❑
Is scum removal adequate?
0
❑
❑
❑
Is the site free of excessive floating sludge?
0
❑
❑
❑
Is the drive unit operational?
0
❑
❑
❑
Is the return rate acceptable (low turbulence)?
0
❑
❑
❑
Is the overflow clear of excessive solids/pin floc?
0
❑
❑
❑
Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth)
0
❑
❑
❑
Comment:
Disinfection -Tablet
Yes No NA NE
Are tablet chlorinators operational?
0
❑
❑
❑
Are the tablets the proper size and type?
0
❑
❑
❑
Number of tubes in use?
4
Is the level of chlorine residual acceptable?
0
❑
❑
❑
Is the contact chamber free of growth, or sludge buildup?
0
❑
❑
❑
Is there chlorine residual prior to de -chlorination?
0
❑
❑
❑
Comment:
Page# 6
Permit: NC0074772
Inspection Date: 08/01/2019
Owner - Facility: Diamond Head WWTP
Inspection Type: Compliance Evaluation
Filtration (High Rate Tertiary)
Yes No NA NE
Type of operation:
Down flow
Is the filter media present?
❑
❑
❑
Is the filter surface free of clogging?
❑
❑
❑
Is the filter free of growth?
❑
❑
❑
Is the air scour operational?
❑
❑
❑
Is the scouring acceptable?
❑
❑
❑
Is the clear well free of excessive solids and filter media?
❑
❑
❑
Comment:
De -chlorination
Yes No NA NE
Type of system ?
Tablet
Is the feed ratio proportional to chlorine amount (1 to 1)?
0 ❑
❑
❑
Is storage appropriate for cylinders?
❑ ❑
0
❑
# Is de -chlorination substance stored away from chlorine containers?
❑ ❑
0
❑
Comment:
Are the tablets the proper size and type? 0 ❑ ❑ ❑
Are tablet de -chlorinators operational? 0 ❑ ❑ ❑
Number of tubes in use? 4
Comment:
Flow Measurement - Effluent
Yes No NA NE
# Is flow meter used for reporting?
0
❑
❑
❑
Is flow meter calibrated annually?
M
❑
❑
❑
Is the flow meter operational?
0
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
❑
❑
0
❑
Comment: The V-notch weir was replaced following the previous inspection. The flow meter was last
calibrated/verified by the CIRC on 3/7/19.
Effluent Pipe
Yes No NA NE
Is right of way to the outfall properly maintained?
❑
❑
0
❑
Are the receiving water free of foam other than trace amounts and other debris?
❑
❑
❑
If effluent (diffuser pipes are required) are they operating properly?
❑
❑
0
❑
Comment: The effluent appeared clear with trace suspended solids and no foam. The effluent is
discharged into the receiving stream through a submerged outfall.
Page# 7
Permit: NCO074772
Owner - Facility: Diamond Head WWTP
Inspection Date: 08/01/2019
Inspection Type: Compliance Evaluation
Effluent Pipe
Yes No NA NE
Pump Station - Effluent
Yes No NA NE
Is the pump wet well free of bypass lines or structures?
0
❑
❑
❑
Are all pumps present?
❑
❑
❑
Are all pumps operable?
❑0
❑
❑
Are float controls operable?
❑
❑
❑
Is SCADA telemetry available and operational?
0
❑
❑
❑
Is audible and visual alarm available and operational?
0
❑
❑
❑
Comment: One of the pumps was in the process of being repaired/replaced.
Aerobic Digester
Yes No NA NE
Is the capacity adequate?
0
❑
❑
❑
Is the mixing adequate?
0
❑
❑
❑
Is the site free of excessive foaming in the tank?
M
❑
❑
❑
# Is the odor acceptable?
0
❑
❑
❑
# Is tankage available for properly waste sludge?
0
❑
❑
❑
Comment: Wastewater solids are removed on an as -needed basis by a contracted company (currently
Rick's Septic Tank Service).
Standby Power
Is automatically activated standby power available?
Is the generator tested by interrupting primary power source?
Is the generator tested under load?
Was generator tested & operational during the inspection?
Do the generator(s) have adequate capacity to operate the entire wastewater site?
Is there an emergency agreement with a fuel vendor for extended run on back-up power?
Is the generator fuel level monitored?
Yes No NA NE
■ ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
Comment: The generator is tested under load on a monthly basis. In addition, the generator is checked
annually and serviced once every two years by a contracted company (Palmer Generator).
Page# 8