Loading...
HomeMy WebLinkAboutWQ0040996_Application (FTSE)_20190809Central Files: APS SWP 7/8/2019 Permit Number WQ0040996 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions A Individual Primary Reviewer Permit Contact Affiliation dean.hunkele Coastal SWRule %�All1lll1lr.M WM Facility Name Major/Minor Region NE Brunswick Eastern Force Main Improvements Minor Wilmington Location Address County Brunswick Owner Owner Name Owner Type Brunswick County Government - County Owner Affiliation John Nichols PE PO Box 249 Dates/Events Bolivia NC 28422024 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 7/5/2019 Reauested /Received Events E G I N E E R S V V 110-1 -L'I", J, SURVEYORS P _A i'\! N F R S RE: Northeast Brunswick Regional Force Main Off -Site Transmission Improvements Sewer Extension Permit Application On behalf of the Brunswick County Public Utilities, we are pleased to submit this permit application for the referenced project, which includes the installation of approximately 11,550 linear feet of 18-inch force main to parallel the existing force main and provide future capacity at the Northeast Brunswick Regional WWTP. Please find enclosed the following documentation: 0 One (1) original and One (1) copy of application form 0 Two (2) copies of 8.5 x 11 color USGS Topographic map 0 Two (2) copies of 8.5 x 11 street map 0 $480 check (permit fee) a One (1) copy of existing flow reduction letter Please note that this is an application for a zero flow permit; therefore, an FTSE form has not been submitted. Please let me know if you have questions or would like to discuss. Thanks for your assistance on this project. Sincerely, McKIM & CREED, INC. 243 North Fron" Street Wilmington, NC 28401 Sean Kenyon, El 910.343.1048 Fax 9-110.251,8282 cc: Brent Lockamy, Brunswick County www.mck;mcreed.com State of North Carolina Department of Environmental Quality R� Division of Water Resources Division of Water Resources 15A NCAC 02T.0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: ,%J �I (to be completed by DWP) I . Applicant's name: Brunswick County Public Utilities (company, municipality, HOA, utility, etc.) 2. Applicant type: 0 Individual ❑ Corporation ❑ General Partnership El Privately -Owned Public Utility El Federal State/County ❑ Municipal ❑ Other 3. Signature authority's name: John Nichols per 15A Nr,AC 02T .O 1106,' Title: Director of Public Utilities 4. Applicant's mailing address: 250 Greywater Rd City: supply State: NC Zip: 28462- 5. Applicant's contact information: Phone number: (210) 253-2657 Email Address: jq �.nicho�lsbru�nswickc� cgov ount m Project name: Northeast Brunswick Regional Forcemain Off -Site Transmission Improvements - Contract I - West 2. Application/Project status: N Proposed (New Permit) 0 Existing Permit/Project If a modification, provide the existing permit number: WQOO_ and issued date: -_ If new construction but part of a master plan, provide the existing permit number: WQOO 3. County where project is located: Brunswick 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.27073' Longitude: -78.00203' 5. Parcel ID (if applicable): N/A (or Parcel ID to closest downstream sewer) 1. Professional Engineer: Anthony W. Boahn, PE License Number: 025512 Firm: McKim& Creed Inc. Mailing address: 243 N. Front St. City: Wilmington State: NC Zip: 28401- Phone number: (9J10) 343 -1048 Email Address: tboahn cz mckimcreed corn 1. Facility Name: Northeast Brunswick Regional WWTP Permit Number: NCO086819 Owner Name: Brunswick County Public Utilities V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Pen -nit Number(s): WQ Downstream (Receiving) Sewer Size: inch System Wide Colicction Sysien-1 Per l NN'UrTiber, l—S) WQCS_ Owner Name(s): FORM: FTA 04-16 Page I of 5 VT. GENERAL REQUIREMENTS L If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? F-1 Yes F-1No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a TD-e-yelop.tr's Op,_-ra DEV) been attached? E]Yes FINo EN/A 1 If the Applicant is a Home/Propervv Ova ners' Association, -has an 0erationa.1 .,koree I p===��nnent (FQR_t\/1: HOA11 been attached? F-1 Yes ❑No ®N/A 4, Origin of wastewater: (check all that apply): ❑ Residential Owned El Retail (stores, centers, malls) 0 Car Wash ❑ Residential Leased El Retail with food preparation/service D Hotel and/or Motels ❑ School / preschool / day care El Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities El Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories El Nursing Home ❑ Other (Explain in Attachment) 5, Nature of wastewater : % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 022:F.01,40- L20)) Is there a Pretreatment Program in effect? F-1 Yes [:]No 6. Hasa flow reduction been approved under! A NCAC 02T.01 J_ifr)? - ®Yes F] No > 7. Summarize wastewater generated by project: Establishment Type (see 02T.01 L-1-41W Daily Design Flow No. of Units i Flow gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total GPD a See 15A NCAC O2T.0114(b')-td)-fe("' and (e'U) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G. S. 42 A -4). b Per 15A NCAC 02 T .0 1 14(c), design flow rates for establishments not identified [ in table 15 A N CAI, 0') T. 0 114I C shall be I I . . determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T.0 114) )> Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit Number: 0 Rehabilitation or replacement of existing sewer with no new flow expected Z Other (Explain): Parallelism of existing force main to decrease pressure on the existing system FORM: FTA 04-16 Page 2 of 5 on w GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02 .0305 , I D13U s Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 18 9225 PVC - C905 24 1350 HDPE - C906 18 695 DI - CI I l 18 280 FPVC - C905 > Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) > Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC PUMP STATION DESIGN CRITERIA (If Applicable) — 02T 0305 & j� DC , P F �e ��� ,�t��i�aj�sl� o�°�e �➢a�ns I . Pump station number or name: N/A 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(! ): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_ � Required for all pump stations with an average daily flow greater than or equal to I5,000 gallons per day > bust be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(I)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - I SA NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORD: FTA 04-16 Page 3 of 5 Ix. SETBACKS & SEPARATIONS — (0213.0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(1) f_g' > 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: 1011010-0 Setback Parameter* Separatign Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains 18 inches Water mains (horizontal) � nta, 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water line 2 feet "Any private or public water supply source, including any wells, WS-I waters of Class I Or Class 11 impounded reservoirs used as a source of drinking, water 100 feet "Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal hi h water or tide elevation and wetlands see item IX.2 50 feet "Any other stream, take, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet An basement 10 feet �o e �of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches �> '15ANC_AC 02T.0305(g) contains alternatives where separations in 02T.0305 r) cannot be achieved. > **Stream classifications can be identified using the Division's NC Surface Water Classifications ,v�-_bpage a� > If noncompliance with 0211.0305(1; or fo, see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) R Yes [:]No [:] N/A > See the Division's draft separation requirements for situations where separation cannot be meet > No variance is required if the alternative design criteria specified is utilized in design and construction )> As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? Z Yes E:1 No [:] N/A > This would include Trout Buffered Streams per L;,A NCAC 2B.0_202 4. Does the project require coverage/authorization under a 404 Nationwide or Z Yes [I No individual permits or 401 Water Quality Certifications? > Information can be obtained from the 401 ez Bu"fer Pernni Branch 5. Does project comply with 15A NCAC 02T.0105,'c)(6) (additional permits/certifications)? Fq Yes El No Per 15A NCAC 02-1 .L)l 05(c_)�6�, directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent pen -nits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. [:]Yes M No El N/A > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). 111077M I MW documented per 15A NCAC 02T.0403(a)(5) or the permitec's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 Does the submitted system comply with 15A �XAC 029T, the �Sinimu Design Criteria for the I'ermittin of Pump Stations and Force _Mqjns {latest versions and the as applicable? R Yes F] No If No, complete and submit the Variance/Alternative Design Request application (VADC 10- 14) and supporting documents for review. ADDroval of the reouastis reanirp.d nrinrtea mhmi4*.1 --A A 2. Pr 01 Jattest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the -Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design, NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation, North Carolina Professional Engineer's seal, signature, and date: 0 3. Applicant's Certification Der 15A NCAC 02T .0106(b): ; ,,4 John Nichols Director Brunswick County Public Utilities —attest that this application for (Signature Authority's name & title from Application Item 1.3,) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $ 10,000 as well as civil penalties up to $25,000 per violation. "A kjt Date: Signature: FORM: FTA 04-16 Page 5 of 5 f--) Northeast Brunswick Regional Force Main Off -Site Transmission Improvements SZ. 1,v,!1.cK11,,M&CREE..., 1 inch = 2,000 feet Project Location Map LRT 4WMM&CREED NORTHEAST BRUNSWICK REGIONAL FORCE MAIN 243 NORTH FRONT ST OFF -SITE TRANSMISSION IMPROVEMENTS MLWNGTON, NORTH CAROUNA 28401 TELE'tt�o 251-alze FAX..USGS TOPOGRAPHIC MAP FIG 1 LICENSE F-1M