Loading...
HomeMy WebLinkAboutWQ0041013_Application (FTSE)_20190710JUL 10 2019 State of North Carolina DWRDepartment of Environmental Quality Raleigh Regional QiiCe Division of Water Resources Dlvlslon of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: A Af L 1l C 13 (to he compicred by DWR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: I. Applicant's name: Town of Clayton (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑General Partnership ❑Privately -Owned Public Utility ❑ FederaI ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Nanc Medlin per ISA NCAC 021 ,0lO.Ll Title: Deputy Town Manager 4. Applicant's mailing address: PO Box 879 City. Clayton State: NC Zip: 27528- m CY y 5. Applicant's contact information: O Phone number: (919) 553-5002 Email Address: asimerman townofcla onnc.or a cv o I1. PROJECT INFORMATION: 'y C= *— , � 1. Project name: Walk at East Villa age - Phase 2 w = 2. Application/Project status: ® Proposed (New Permit) ❑Existing Pen-nit/Project If a modification, provide the existing permit number: WQ00 and issued date: A If new construction but part of a master plan, provide the existing permit number: WQ00 Z 3. County where project is located: Johnston 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.642508 Longitude:-78.443888 5. Parcel 1D (if applicable): 166807-59-0985 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: James David Arnold PE License Number: 036865 Firm: The Nau Comnanv. PLLC Mailing address: PO Box 810 City: Rolesville State: NC Zip: 27571- Phone number: (919) 630-2552 Email Address: damold c-thenauco.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: Little Creek WRF Permit Number: 0025453 Owner Name: Town of Clayton V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ0038698 Downstream (Receiving) Sewer Size: 8 inch Sysjcjn Wide Collection System Permit Nteaitlej: WQC500147 Owner Name(s); Town of Clayton FORM: FTA 04-I6 Page I of 5 VI. GENERAL REQUIREMENTS L If [lie Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached-? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Develn eCs Operational Agreement FORM: DI V been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Hone/PropertyOwners' Association has an O erational Agreement FORM: HOA been attached'? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ ❑Car Wash Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School 'preschool ;` day care ❑ Medical i dental i veterinary facilities ❑ Swimming Pool :Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filtcr Backwash ❑ Businesses' offices factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater, 100 Residential % Domestic/Commercial 0 % Commercial 0 °'o Industrial (See 15A NCAC 02T .0103 20 ) -Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .01 t 4 ? ® Yes []No If yes, provide a cony of now reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.01140 57 Single Family Homes Daily Design Flow'-b INo. of Units] Flow 250 gal/day 57 14,250 GPD gap GPD gal/ GPD gal/ GPD gal: GPD gal. GPD Total 14,250 GPD a See 15A NCAC 02T .0114 b d c I and w 2 for caveats to wastewater design flow rates (i.e_, minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property Iocated south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A4). b Per 15A NCAC 02T .Oi 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 14] shall be determined using available flow data, water using fixtures, occupancy or operation pattems, and other measured data. S. Wastewater generated by project: 1. 4,= GPD (per i 5A NCAC 02T .0114) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VIL GRAVITY SEWER DESIGN CRITERIA tIf Applicable) -1}2T .03tt5 & AIDC (Gra%j1v Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material S I1631 PVC Section lI & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — t12T .0305 & ,1IDC(Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude. 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with I SA NCAC 021 .0305 h 1 : ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_; Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow Iess than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 021' .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with The station. 11 10, If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump. including travel timeframes, shall be provided in the case of multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & I5A NCAC 02T .0305(f)): I. Does the project comply with all separations found in 15A NCAC 02'I .0305t ff & (g) ® Yes ❑ No "r 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305 cannot be achieved. "*Stream classifications can be identified using the Division's NC Surface Water C_ lassifications webnage % if noncompliance with 02T.0305 or see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ❑ N.-'A See the Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction % As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200'? ® Yes ❑ No ❑ NIA This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ® Yes [:)No individual permits or 401 Water Quality Certifications? % Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes []No Per I5A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance ofdependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer' means "any aerial seer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ®No ❑ N: A % If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance.+Altemative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required 2rior to submittal of the Fast Track Application and supporting documents. 2_ Professional Engineer's Certification_ 1, James David Arnold, PE (Professional Engineer's name from Application Item IIL1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to S25,000 per violation. North Carolina Professional Engineer's seal, sign#cure, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): `,11y1111111111f/++i • ,�'y la's S i tiN. / DA V t O Ap ,,�•. �++++r111111111111, 07/10/2019 Maow rl . 1= U�`f _ cur4 mf}m)q tpeyt attest that this application for (Signature Authority's name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required pans of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a CIass 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: f Date: �i FORM: FTA 04-16 Page 5 of 5 NC Dept of Environmental Quality JUL 10 2l Raleigh Regional Office State of Department of Enviro North Carolina Divisionnmental Quality. 1'ntitY Re F!o}v TracEin of 13'ater Resources questing Allocation; g for SeyVer Extension A Project Na Tow of Nam, for which n Cla Applications �1nre flow is b on �Frslr 10-18) QT rhnp nice F]SE In Err etng requested; r4uiredfar Walk 1 C slatinns' aIn a srgR�ep►�jecr aEast Vi11a a Ph a ° fete this secthe ion only if o �`� !/re rngrr q/ r/r ��111'w H psle alrfiiIT . not respan� WrP Facility n Y u are the rJlny; r6/efnrn/Ipam owner of the wastewater treat b. 1Vlyrp Facility pe me' Little Cre unit #7fJ,),,, S4S3 ek W ll RF lent plant. c. WWrp facility's Permitted. Esti Estimated obligated All flay�,5 e. flow not LCWRF , are tit AfGD WTp facility's actual Yet trio Rai - , —5 + J°Co 1.34 + . Total flow for al all f7 utary to the WWrp 0.8342 1.0 g' Total actual andhis specific request h. Percent to obligated /lot► s 2.9263 pe1ntitied e faci tlow. used / to the 0.0143 Il. Complete 3.6748 waste , this section for �+ ater flow 76 Sb% cacti Pump station you are res List putnP station,Ponsible for along t located betw he route of this proposed between the project co pump nnection point and Station pump (A) the WWrp; Station Design (B) (Naln tu Num1b or Permit rill A vera a (C) ber) No. Capacity,DailyFlowll APprax Obligated, (D)�(BfC) (Fi Cu Not yet Arbors �iCD � � pI), 'Tent W 36203 h4l Avg Dail Tributary rota! Current 0.56$g FloIt-. Nil Daily Flo It, Plow Plus 0.2?7S Al Obligated Available 0.U223 Floe• 0.0143 rapacitylll 0.0366 0.1909 that he Firm Ca Aacity. id cart be achieved gn no --- the of Design►pith the largestany Pum gvera y Flow • pum A statiofse defGaed ~a apt} not less ge Dsil • P taken oat as the than 2.s, per Sessl is the fir r►'ice. rimnm ** A plannin ction 2.4lm capacih• ofthe pumped Ao►v be the project connect • ndutn shall be of the A p'num station di►ided by, apeaking Addc ctton ll be attached gn Criteria. factor Downstream Facility Na point for each �ou'nstre and the 1L�p where the pul station located am permit me iSewerj: Walk Available Ca Number; at East Villa Capacity is p• WQ0038698 e Ph 1 Page ! f6 ta_... The Nau Company Unsulting Civil Engineers August 8, 2019 NC Department of Environmental Quality Division of Water Resources Raleigh Regional Office RE: Walk at East Village Phase 2 Sanitary Sewer Permit Dear Sir/Madam: Attached are the required documents for the permitting of the gravity sanitary sewer line required for Phase 2 of the existing Walk at East Village Subdivision located in Clayton, NC. This phase shall include approximately 1,631 If of 8" PVC gravity sewer that will serve 57 proposed single family lots. Per previously approved flow reduction letter, a flow of 250 gpd lot will be required for a total flow of 14,250 gpd. If you have any questions or concerns, please let me know. Sincerely, The Nau Company, PLLC David Arnold, PE darnold@thenauco.com PO Box 810 / Rolesville, North Carolina 27571 / (919) 435-6395 i��. \� � r �/ �r�-i � �" � �� � t��-y�.r � ,� _�: r. • art, � �,; +�► ` r \ V ... /�✓ice. v: :,'� S 1 f I �1 'I!' Ir r.- ��! , e 1 �l1if!%f _ram !L K"�i • �1,�•'i� �A 'tie ��_•-�� � I �.-. ,��- t. )'--f�y��� NX IN � • �� Jam' i � � • j � , 7 + _ ./�� ( u�Rf �i ._.Y•�I �'.� F • �rti,,. NJ .� �j"I � ter'^ '� �'� tl ' � i• '3i• �• r�� J r �`�'.�`\ice \,' �,�✓ { ry ! ry '�i •� ,k ft��;r, I.`�l i �� IN IZ '-3:t.�, h, ,`?� "y ��� t.� ��• _:,mot' *ti\I 1} � a � �c -^� I�- ��� \i •j•�n,1.. SRO �-r �- J 1G �..� .�lr u CL H Gf -o 0 a a m E f g Ln 0 d . State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Kerr T. Stevens, Director Mr- Steve Biggs, Town Manager Town of Clayton Post Office Box 879 Clayton, North Carolina 27520 Boar Mr. Biggs: NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES July 2, 2001 NC Dept of Environmental Qualit\ JUL 10 2019 Raleigh Regional Office Subject_ Town of Clayton Flow Reduction Approval Johnston County On January 3, 2001, the Division of Water Quality received your flow reduction request for new single-family dwellings in the Town of Clayton. The letter requests approval of a residential flow value of 250 GPD/residence for any future dwellings that may become tributary to the subject wastewater collection system. The Division also received additional information on April 3, 2001 The information provided flow records between January 1998 and November 2000 for the W WTP. The evaluation also included the daily wastewater flows for a 33 day period from February 19 through March 23, 2001 for a select 97 homes in accordance with 15A NCAC 2H .0219(I)(3). Based upon the information submitted, the Division hereby approves the use of 250 GPD per single- family residence in all applicable non -discharge permit applications for future sewer line extensions for the Town of Clayton. This consideration applies to any applicable future projects submitted to the Division as well as any projects which are currently under review. Reyardles,. of the atdiusled dcciert daily ►vmstiwatcr flow rate, at no time shall the wastewater flows exceed the cffEurni limits drl'tne�l in ihr Tr�t�n's Nl'I71 5 ne rntiE for the IML1311011 IacihtUI tlxcuedu llle ca tacit cif the -; %ver,; downjrcagr of any netiv sower e.Vcrtsion- If you have any questions or comments regarding this maticr, please contact Mr. Kim H. Colson at (919)733-5083 ext. 540, Sir -0 ely. >>� Kerr 7'. 5teverr, rc Raleigh Regional Office 1617 Mull Service Center, Raleigh, North Carolina 27699- 1617 Telephone 919-733-5083 Fax 919 715-6048 An Equal Opportunity Affirmative Action Ftrployer 50% recycled/I0% post consumer paper The Nau Company Consulting Civil Engineers PO Box 810 Rolesviile, NC 27571 919-435-6395 TRANSMITTAL Deliver to NCDEQ Raleigh Regional Office Water Quality Section 3800 Barrett Drive Raleigh NC 27609 919-791-4200 Project name Submittal type Project number Sender David Arnold, PE 919-630-2552 Date July 10, 2019 Delivery method Hand Delivery The Walk at East Village - Phase 2 Sanitary Sewer Permit Quantity Date Description 2 07/10/19 Fast Track Application 1 07/10/19 Check for $480 2 07/10/19 Flow Tracking/Acceptance - Fuquay Varina 2 07/10/19 Flow Reduction Letter 2 07/10/19 USGS Quad Map Z 07/10/19 Aerial Map IVII M$ Comments/Notes Please see attached application and documents for your review. This is for a Phase 2 of the existing Walk at East Village Subdivision in Clayton NC. Please let me know if you have any questions or comments. Thanks, David Deck, Erin M From: David Arnold <darnold@thenauco.com> Sent: Thursday, August 8, 2019 2:18 PM To: Deck, Erin M; Andrew Simerman Subject: [External] RE: Walk at East Village -Phase 2 Fast Track Sewer extension application Attachments: 2019-08-08 Walk at East Village Phase 2 Cover Letter and Permit Application Package.pdf r _ Externatemail. Do not ai a licks or open attachments unless you verify. Send all suspicious emal[as an attachment to imp aq.sPdff4L nG:J 4.Y Erin, Attached is a new cover letter and previously submitted information. Please let me know if this addresses your comments. We do not have any high priority lines. I believe the "No" box was checked on the application. We have streams onsite but nothing we are proposing crosses them. Thanks, David Amold, PE The Hau Company d Mobile (919) 630-2552 www.thenauco.com From: Deck, Erin M <erin.deck(@ncdenr.eov> Sent: Wednesday, August 7, 2019 1:29 PM To: darno[d@thenauco.com; Andrew Simerman <asimerman@townofclaytonnc.ore> Subject: Walk at East Village -Phase 2 Fast Track Sewer extension application Good Afternoon, I am in the process of reviewing the subject application and require additional information. -Per the general instructions, a cover letter is required. Please submit a cover letter with the system type, number of homes served, flow allocation required etc. If necessary for clarity, include attachments. -Please verify that there are no high priority lines("any aerial sewer, sewer contacting surface waters, siphons or sewer positioned parallel to stream banks") as there appear to be streams in the project area. Once this information is received, I can move forward with drafting this permit. Thank you. Erin Deck Department of Environmental Quality Division of Water Resources Raleigh Regional Office Office: 919-791-4258