Loading...
HomeMy WebLinkAboutWQ0040959_Application (FTSE)_20190630 ISAACS o I CIVIL ENG820 INERING RED OAKDESIGN & LAND BOULEVARD, STE.R4201NG LETTER OF TRANSMITTAL CHARLOTTE, N.C. 28217 DATE: 7/t g/2019 JOB NUMBER: 18097 PHONE (704) 527-3440 FAX (704) 527-8335 ATTENTION: Jenny Graznak i RE: Westchester County Day School TO NCDEMLR Sewer Extension Permit Land Quality Dept. 450 West Hanes Mill Road, Ste. 300 Winston Salem, NC 27105 WE ARE SENDING YOU❑ Attached ❑ under Separate cover via the following items: ❑ Shop drawings ❑ Prints ❑ Plans ❑ Applications ❑ Specifications I ElCopy of letter ❑ Disk ❑ l COPIES DATE NO. DESCRIPTION 1 Revised FTA 2 Revsised FTSE from Aqua 1 Revsied flow calculation it l THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ Approved and submitted ❑ Resubmit copies for approval .I ❑ For your use -1Approved as noted ❑ Submit copies for distribution ❑ As requested ❑ Returned for corrections ❑ Return corrected prints ❑ For review and comment ❑ _ REMARKS Jenny, per our recent discussions, attached find the items listed above. The FTA, FTSE and calcs have been revised to reflect the measured sewer flow coming from the school along with a new flow of 9,702 GPD. The FTA has also been revised to pull in the length of exsiting sewer that we are connecting to that today is not permitted as either the School's or Aqua's. Please let me know if y ou have any quesitons. you can email me at bcowan@isaacsgrp.com, or call at 704-227-9402. NC Departrnent o€ Environmental Quality Received JUL 2 2 2019 I Winston-Salem Regional Office COPYTO File SIGNED Brent Cowan State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T.0300-FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Dlvislon of Water Resources �� FTA 04-16&SUPPORTING DOCUMENTATION Application Number: q O M(to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Westchester Country Day School(company,municipality,HOA,utility,etc.) 2. Applicant type: ❑ Individual ® Corporation ❑General Partnership ❑Privately-Owned Public Utility ❑Federal ❑ State/County ❑Municipal ❑ Other 3. Signature authority's name: Cobb Atkinson per 15A NCAC 02T .0106(b) N C D e partment of Title:Headmaster Environmental Quality Received 4. Applicant's mailing address: 2045 N. Old Greensboro Road JUL 2 2 2019 City:High Point State:NC Zip:27265- 5. Applicant's contact information: Winston-Salem Phone number: (336) 869-2126 Email Address: CobbAtkinson@westchestereds.or¢ Regional Office H. PROJECT INFORMATION: i 1. Project name: Westchester Country Day School 2. Application/Project status: ®Proposed(New Permit) ❑Existing Permit/Project If a modification,provide the existing permit number:WQ00 and issued date: If new construction but part of a master plan,provide the existing permit number:WQ00_ 3. County where project is located:Davidson 4. Approximate Coordinates(Decimal Degrees): Latitude: 35.9735' Longitude: -80.0898° 5. Parcel ID(if applicable): 6871-04-80-0951 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer:Anthony Brent Cowan,P.E. License Number: 026462 Firm:The Isaacs Group,PC Mailing address: 8720 Red Oak Blvd., Ste 420 i City:Charlotte State:NC Zip:28217-_ Phone number: (704)227-9402 Email Address:bcowanCo)isaacsgty com IV. WASTEWATER TREATMENT FACILITY(WWTF)INFORMATION: 1. Facility Name:Willow Creek W WTP Pemrit Number:NCO034452 Owner Name: Aqua North Carolina,Inc. l V. RECEIVING DOWNSTREAM SEWER INFORMATION(if different than WWTF): 1. Permit Number(s):WQ Downstream(Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable):WQCS Owner Name(s):Aqua Carolina j I FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately-Owned Public Utility,has a Certificate of Public Convenience and Necessity been attached? ❑Yes ®No ❑N/A i 2. If the Applicant is a Developer of lots to be sold,has a Developer's Operational Agreement(FORM:DEV)been attached? ❑Yes [:]No ®N/A 3. If the Applicant is a Home/Property Owners'Association,has an Operational Agreement(FORM:HOA)been attached? ®Yes ❑No ❑N/A 4. Origin of wastewater: (check all that apply): ❑Residential Owned ❑Retail(stores,centers,malls) ❑Car Wash ❑Residential Leased ❑Retail with food preparation/service ❑Hotel and/or Motels ® School/preschool/day care ❑Medical/dental/veterinary facilities ❑ Swimming Pool/Clubhouse ❑Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑Businesses/offices/factories ❑Nursing Home ❑ Other(Explain in Attachment) 5. Nature of wastewater: 100%Domestic/Commercial %Commercial %Industrial(See 15A NCAC 02T.0103(20)) "Is there a Pretreatment Program in effect? ❑Yes ❑No 6. Hasa flow reduction been approved under 15A NCAC 02T.0114(fl? []Yes ❑No ➢ If yes,provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type(see 02T.0114(f)) Daily Design Flow a,b No.of Units Flow Existing flow(see calcs) gal/ 3,204 GPD New flow from proposed additions gal/ 9,702 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 9,702 GPD i a See 15A NCAC 02T .0114(b), (d),(e)(1) and(e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling;proposed unknown non-residential development uses;public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S.42A-4). b Per 15A NCAC 02T.0114(c),design flow rates for establishments not identified[in table 15A NCAC 02T.01141 shall be determined using available flow data,water using fixtures,occupancy or operation patterns,and other measured data. 8. Wastewater generated by project: 9 702 GPD(per 15A NCAC 02T.0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero,indicate why: ❑Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑Flow has already been allocated in Permit Number: ❑Rehabilitation or replacement of existing sewer with no new flow expected ❑Other(Explain): FORM: ETA 04-16 Page 2 of 5 VH. GRAVITY SEWER DESIGN CRITERIA(If Applicable)-02T.0305&MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size(inches) Length(feet) Material 8 40 DIP 8 1,147 PVC 8 341.93-existing unknown ih ➢ Section II&III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ICI ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIH. PUMP STATION DESIGN CRITERIA(If Applicable)—02T.0305&MDC(Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name:N/A 2. Approximate Coordinates(Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day(firm capacity) I 4. Operational point(s)of the pump(s): _gallons per minute at_feet total dynamic head(TDH) 5. Summarize the force main to be permitted(for this Pump Station): f Size(inches) Length(feet) Material i, 6. Power reliability in accordance with 15A NCAC 02T.0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry- 15A NCAC 02T.0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation,quick-connection receptacle and telemetry- 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry- 15A NCAC 02T.0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant(draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations,an evaluation of all the pump stations'storage capacities and the rotation schedule of the portable power source or pump, including travel timeftames, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 ) I WASTEWATER DESIGN FLOW RATES Date:07/12/19 j PROJECT: WESTCHESTER COUNTY DAY SCHOOL Narrative: The purpose of this calculation is to show the exisiting sewer flow rate for the Westchester County Day School,and the proposed sewer flow rate for the proposed facility improvements including a new Performing Arts Center,a new fieldhouse and a new Gymnasium. j NORTH CAROLINA ADMINISTRATIVE CODE T15A NCAC 02T.0114(Effective January 1, 2009)Page 10-12 EXISTING SEWER FLOWS Type of Establishment Gallons Area(sf) Seats Employees Other Units Daily(gal) ; Average Annual Notes Daily(gal) Westchester Country Day School Schools Schools with Cafeteria,Gym and Showers. 3,204 Note#1 t PROPOSED SEWER FLOWS Type of Establishment Gallons Area(sQ Seats Employees Other Units Daily(gal) Average AnnualDaily(gal) Notes I Fieldhouse(Concessions)- Food and Drink Facilities Specially Food Stand or Kiosk 50 gal 1100 sq.ft.floor space 50 243 122 Fieldhouse(Restrooms) Parks,Recreation and other Outdoor Activity Facilities Parks with Restroom Facilities 250 gal/plumbing fixture 250 14 fixtures 3,500 Finch Gymnasium Sports Centers Gymnasium 50 gal 1100 sq.ft 50 7,000 3,500 i Performing Arts Center Stadiums,Auditoriums, Theaters Community Centers 5 gal/seat 5 516 2,580 Design Flow Rate Increase: 9,702 gpd (404 gph) Total Flow Rate: 12,906 gpd (Exist.+Prop.) (538 gph) Notes 1)calculated average daily flow from existing school using measured flow provided by Davidson Water from 4 existing meters on campus. See calcs titled"Westchester-2 years flow data charts.pdf l P:Wctive Projects\WGM\Westchester 18097\Engineering\Calculations\Waste Water Flow\18097-SS FLOW CALC.xIs N c Department of Environmenial Quality Received State of North Carolina JUL 2 2 Loan Department of Environmental Quality �.x,,.. Division of Water Resources Winston-Salem Flow Tracking for Sewer Extension Applications Division of waterttescrur��s g PP Regional Office (FTSE 10-18) Entity Requesting Allocation: Westchester County Day School Project Name for which flow is being requested: Westchester County Day Schl Expansion More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Willow Creek WWTP b. WWTP Facility Permit#: NCO034452 AU flows are in MGD c. WWTP facility's permitted flow .080 d. Estimated obligated flow not yet tributary to the WWTP 0.00 e. WWTP facility's actual avg. flow 0.041 f. Total flow for this specific request 0.009702 MGD g. Total actual and obligated flows to the facility 0.050702 h. Percent of permitted flow used 63% III. Complete this section for each pump station you are responsible for along the route of this proposed j wastewater flow. f i List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity,* (Firm/p0, Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow,MGD MGD Flow Capacity*** LS#3 Unknown 0.1397 0.0559 0.0134 0.009702 .023102 .0328 LS41 Unknown 0.2016 0.0806 .0547 0.009702 0.064402 0.0162 i * The Firm Capacity(design flow)of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. **Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf)not less than 2.5,per Section 2.02(A)(4)(c) of the Minimum Design Criteria. ***A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is<0. Downstream Facility Name (Sewer): Willow Creek-HP Collection System Downstream Permit Number: Un Known Page 1 of 6 FTSE 10-18 III. Certification Statement: I Micahel A. Melton certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements j identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. I Signing fficial Signature Date I Engineering Manager Title of Signing Official Page 2 of 6 PTSE 10-18 I Graznak, Jenny From: Graznak,Jenny Sent: Friday, June 21, 2019 12:15 PM To: Brent Cowan Cc: Henderson,Justin L Subject: RE: [External] RE:Westchester Country Day School From the attachment to application entitled "Wastewater Design Flow Rates": Fieldhouse (Concessions)—122 gpd Fieldhouse (restrooms)—3,500 gpd Finch Gymnasium—3,500 gpd Performing Arts Center—2,580 gpd TOTAL= 9,702 gpd For fast track,we cannot assign daily flows for partial use facilities.You would need to request a variance from our central office for that. Jenny Graznak Environmental Specialist II Winston Salem Regional Office Division of Water Resources 336-776-9695 office 336-403-7388 mobile jenny.graznak@ncdenr.gov 450 W Hanes Mill Road Winston Salem NC 27105 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Subscribe to Collection System & Sewer Permitting Updates From: Brent Cowan <bcowan@isaacsgrp.com> Sent: Friday,June 21, 2019 11:52 AM To: Graznak,Jenny<jenny.graznak@ncdenr.gov> Cc: Henderson,Justin L<justin.henderson@ncdenr.gov> Subject: [External] RE: Westchester Country Day School Good morning Jenny, I Can you please break down how you arrived at 9,702 GPD? Thanks, t �4 I Anthony Brent Cowan, P.E., LEEWAP The Isaacs Group, P.C. 8720 Red Oak Blvd., Ste. 420 Charlotte, NC 28217 P: 704-227-9402 F: 704-527-8335 Web: www.isaacsgrp.com I From: Graznak,Jenny<ienny.graznak@ncdenr.gov> Sent: Friday,June 21, 2019 8:41 AM To: Brent Cowan <bcowan@isaacsgrp.com> Cc: Henderson,Justin L<iustin.henderson@ncdenr.gov> Subject: Westchester Country Day School Good morning, We have reviewed the application for Westchester Country Day School in Davidson County. The total flow that we will need to permit is 9,702 GPD based on the daily design flows in the regulations. For fast track,we cannot use fractions or days per week of flow. If you want to have it permitted that way,you would need to apply through our central office for a regular review instead of fast track.Also,we cannot allow credits (or subtraction in flow) since the current flow is not permitted with the Division. So the permit application will need to be resubmitted with a flow request of 9,702 GPD and a new FTSE. We will hold the application until we receive it. Please contact me with any questions.Thank you. i Jenny Graznak Environmental Specialist II Winston Salem Regional Office Division of Water Resources 336-776-9695 office 336-403-7388 mobile jenny.graznak@ncdenr.gov 450 W Hanes Mill Road Winston Salem NC 27105 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Subscribe to Collection System & Sewer Permitting Updates f 2 ISAACS o f CIVIL ENGINEERING RED OAK ERIDESIGN BOULEVARD, STE.R4201NC LETTER OF TRANSMITTAL CHARLOTTE, N.C. 28217 PHONE (704) 527-3440 FAX (704) 527-8335 DATE: 6/13/2019 JOB NUMBER: 18097 ATTENTION: Water Quality Section-Sewer Permitting RE: Westchester County Day School TO NCDEMLR Water Quality Section 450 West Hanes Mill Road, Ste. 300 Winston Salem, NC 27105 WE ARE SENDING YOU❑ Attached ❑ Under Separate cover via the following items: ❑ Shop drawings ❑ Prints ❑ Plans ❑ Applications ❑ Specifcations ❑ Copy of letter ❑ Disk ❑ COPIES DATE NO. DESCRIPTION 1 Sewer Fast Track Package inlcudes cover letter, FTA 04-16 app, Flow Tracking Form FTSE 04-16, USGS color map, Street level map and operation agreement 1 copy of Fast Track Package 1 $480 check i i I i THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ Approved and submitted ❑ Resubmit copies for approval ❑ For your use ❑ Approved as noted ❑ Submit copies for distribution j ❑ As requested ❑ Returned for corrections ❑ Return corrected prints ❑ For review and comment ❑ REMARKS Enclosed items listed above for review. Should you have any quesitons or need add'I information, please contact me at bcowan@isaacsgrp.com or 704-227-9402. NC Department of Environmental Quality Received JUN 14 2019 Winston-Salem r Regional Office COPYTO File SIGNED Brent Cowan ISAACS o CIVIL ENGINEERING DESIGN AND LAND SURVEYING C 8720 RED OAK BOULEVARD, STE. 420 CHARLOTTE, N.C. 28217 NC Department of I PHONE (704) 527-3440 FAX (704) 527-8335 Environrnental Quality Received i Project Narrative JUN 14 2019 Winston-Salem Westchester County Day School Regional office Union County, North Carolina The project site is the existing Westchester Day School located at 2045 N. Old Greensboro Road in Davie County, North Carolina. The campus is comprised of 1 parcel (Parcel Number 0102100000024)totaling approximately 49 acres with existing buildings, parking lots and sports fields. The project involves the following improvements/additions to the campus: • Addition of a new Performing Arts Center • New access road from existing parking lot off Cascade Drive with parking lot and truck loading dock/service area to the new Performing Arts Center • A new proposed basketball court located north of new parking lot and west of Cat's Den gymnasium • Proposed building expansion at existing Gymnasium • Design of interconnectivity between Cats Den, New PAC and Gymnasium via sidewalks, steps and ADA ramps • Soccer field reconfiguration required due to Gymnasium expansion • Demolition of existing cul-de-sac and relocation of existing playground on north side of Smith Hall • Reconfiguration of parking area and addition of a Bell Tower on north side of Finch Center • Addition of a new parking lot off Wildcat Trail on north side of baseball field • Addition of a new roundabout and student drop-off area on Wildcat Trail • Addition of 6 new tennis courts located west of existing soccer field and south of new PAC • Demolition of existing field house and add new field house north of soccer field Sewer flow to be generated by this project is 1,107 GPD (reference attached sewer flow calculations). The sewer collection system within the project site will be provided by a series of 8 inch gravity lines privately owned and maintained by Westchester County Day School. The proposed sewer system will tie into existing downstream 8 inch sewer lines (Permit #WQ unknown ) owned and maintained by Aqua Carolina and will be treated at the Willow Creek WWTF (Permit# NC0034452), which is owned by Aqua Carolina. Please see the following in the attached application package: • One Original and One Copy of Application • Application Fee of$480 written out to NCDEQ • Fast Track Application • Flow Tracking/Acceptance Form • Site Maps 0 8.5"x11" color copy of USGS topo o Street level map PAActive Projects\WGM\Westchester 18097\Engineering\Correspondence\Forms&ApplicationsINCDEQ- SS\Westchester Sewer Cover Letter.doc State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T.0300—FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources ( FTA 04-16&SUPPORTING DOCUMENTATION Application Number. �Q�O (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Westchester Country Day School(company,municipality,HOA,utility,etc.) 2. Applicant type: ❑Individual ® Corporation ❑General Partnership ❑Privately-Owned Public Utility El Federal ❑ State/County ❑Municipal ❑Other 3. Signature authority's name: Cobb Atkinson per 15A NCAC 02T.0106(b) Title:Headmaster NC Department ofEnvironmental Quality 4. Applicant's mailing address: 2045 N. Old Greensboro Road Received City:High Point State:NC Zip:27265-_ JUN 14 2019 5. Applicant's contact information: Winston-Salem - Phone number: (3� 869-2126 Email Address: CobbAtkinson(ct�,westchestercds.org Regional Office II. PROJECT INFORMATION: 1. Project name: Westchester Country Day School 2. Application/Project status: ®Proposed(New Permit) ❑Existing Permit/Project If a modification,provide the existing permit number:WQ00 and issued date: If new construction but part of a master plan,provide the existing permit number:W000 3. County where project is located:Davidson 4. Approximate Coordinates(Decimal Degrees): Latitude: 35.9735' Longitude: -80.0898' 5. Parcel ID(if applicable): 6871-04-80-0951 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Anthony Brent Cowan,P.E. License Number: 026462 Firm:The Isaacs Group,PC Mailing address: 8720 Red Oak Blvd.,Ste 420 City: Charlotte State:NC Zip:28217-_ Phone number: (704)227-9402 Email Address:bcowan(n,,isaacsem.com IV. WASTEWATER TREATMENT FACILITY(WWTF)INFORMATION: 1. Facility Name: Willow Creek W WTP Permit Number:NCO034452 4 Owner Name: Aqua North Carolina,Inc. V. RECEIVING DOWNSTREAM SEWER INFORMATION(if different than WWTF): i 1. PermitNumber(s):WQ Downstream(Receiving)Sewer Size: inch System Wide Collection System Permit Number(s)(if applicable): WQCS Owner Name(s): i FORM: FTA 04-16 Page 1 of 5 VL GENERAL REQUIREMENTS 1. If the Applicant is a Privately-Owned Public Utility,has a Certificate of Public Convenience and Necessity been attached? ❑Yes ®No ❑N/A 2. If the Applicant is a Developer of lots to be sold,has a Developer's Operational Agreement(FORM: DEV)been attached? i ❑Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners'Association has an Operational Agreement(FORM:HOA)been attached? ®Yes ❑No ❑N/A 4. Origin of wastewater: (check all that apply): ❑Residential Owned ❑Retail(stores,centers,malls) ❑Car Wash ❑Residential Leased ❑Retail with food preparation/service ❑Hotel and/or Motels ® School/preschool/day care ❑Medical/dental/veterinary facilities ❑ Swimming Pool/Clubhouse ❑Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑Businesses/offices/factories ❑Nursing Home ❑Other(Explain in Attachment) 5. Nature of wastewater: 100%Domestic/Commercial %Commercial %Industrial(See 15A NCAC 02T.0103(20)) "Is there a Pretreatment Program in effect? ❑Yes ❑No 6. Hasa flow reduction been approved under 1'5A NCAC 02T.0114(f)? ❑Yes ❑No ➢ If yes provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type(see 02T.0114(1)) Daily Design Flow°,b No.of Units Flow See attached flow calculations gal/ GPD gal/ GPD gal/ GPD i gal/ GPD gal/ GPD gal/ GPD Total 1,107 GPD a See 15A NCAC 02T 0114(b). (d). (e)(1)and(e)(2)for caveats to wastewater design flow rates (i.e.,minimum flow per dwelling;proposed unknown non-residential development uses;public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S.42A-4). b Per 15A NCAC 02T.0114(c),design flow rates for establishments not identified[in table 15A NCAC 02T.0114] shall be determined using available flow data,water using fixtures,occupancy or operation patterns,and other measured data. 8. Wastewater generated by project: 1 107 GPD(per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero,indicate why: ❑Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑Flow has already been allocated in Permit Number: ❑Rehabilitation or replacement of existing sewer with no new flow expected ❑Other(Explain): FORM:FTA 04-16 Page 2 of 5 i VII. GRAVITY SEWER DESIGN CRITERIA(If Applicable) 02T.0305 &MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size(inches) Length(feet) Material 8 40 DIP 8 1,147 PVC �I ➢ Section II&III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VHI. PUMP STATION DESIGN CRITERIA(If Applicable)—02T.0305&MDC(Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name:N/A 2. Approximate Coordinates(Decimal Degrees): Latitude: 0Longitude: - ° 3. Design flow of the pump station: millions gallons per day(firm capacity) 4. Operational point(s)of the pump(s): _gallons per minute at feet total dynamic head(TDH) 5. Summarize the force main to be permitted(for this Pump Station): Size(inches) Length(feet) Material 6. Power reliability in accordance with 15A NCAC 02T.0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry- 15A NCAC 02T.0305(h)(1)(B): '.. ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation,quick-connection receptacle and telemetry- 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry- 15A NCAC 02T.0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant(draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations,an evaluation of all the pump stations'storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes,shall be provided in the case of a multiple station power outage. FORM:FTA 04-16 Page 3 of 5 IX. SETBACKS&SEPARATIONS—(02B.0200 &15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T.0305(f)&(e) ®Yes ❑No P J f ➢ 15A NCAC 02T.0305 contains minimum separations that shall be provided for sewers stems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical-water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical-reclaimed over sewer 18 inches Reclaimed water lines horizontal-reclaimed over sewer 2 feet **Any private or public water supply source,including any wells,WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS(except WS-I or WS-V),B, SA,ORW,HQW,or SB from normal h high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream,lake,impoundment,or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Anybasement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches i ➢ 15A NCAC 02T.0305(e)contains alternatives:where separations in 02T.0305(f)cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(f)or(g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ®Yes ❑No ❑N/A fk ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ®Yes ❑No ❑N/A ➢ This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑Yes ®No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 &Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6)(additional permits/certifications)? ®Yes [-]No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans,stormwater management plans,etc.). 6. Does this project include any sewer collection lines that are deemed"high-priority?" Per 15A NCAC 02T.0402, "high-priority sewer"means"any aerial sewer, sewer contacting surface waters,siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑Yes ®No ❑N/A ➢ If yes;include an attachment with details for each line,including type(aerial line,size,material,and location). High priority lines shall be inspected by the permittee or its representative at least once every six-months and inspections documented per 15A NCAC 02T.0403(a)(5)or the permitee's individual System-Wide Collection permit. FORM:FTA 04-16 Page 4 of 5 CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T,the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains(latest version),and the Gravity Sewer Minimum Design Criteria(latest version)as applicable? ®❑Yes ❑❑No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineers Certification: 1, CCI-40 attest that this application for (Professional Engineer's name from Application Item III.1.) I has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations,and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package,inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed$10,000,as well as civil penalties up to$25,000 per violation. North Carotins Professional Engineer's seal,signature,and date: ""'�®®®®oji`i�eC ®®��""""' PpFESsj0 0611312"S p� 0,,26 /NEI P: ' 3. Applicant's Certification per 115A NCAC 02T.0106(b): `""'""'"'eao�� I 1�R Q-'3K114gn Y e"Irik-razz attest that this application for (Signature Authority's name&title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non- discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included,this application package will be retuned to me as incomplete. NOTE— In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed$10,000 as well as civil penalties up to$25,000 per violation. i Signature: Date: FORM:FTA 04-16 Page 9 of 5 I WASTEWATER DESIGN FLOW RATES Date:0 411 6/2 01 9 PROJECT: WESTCHESTER COUNTY DAY SCHOOL i Narrative: The purpose of this calculation is to show the exisiting sewer flow rate for the Westchester County Day School,and the proposed sewer flow rate for the proposed facility improvements including a new Performing Arts Center,a new fleldhouse and a new Gymnasium. NORTH CAROLINA ADMINISTRATIVE CODE T15A NCAC 02T.0114(Effective January 1,2009)Page 10-12 I EXISTING SEWER FLOWS i Days Per Average Annual I� Type of Establishment Gallons Area(at) Seats Employees Other Units Daily(gal) Week Daily(gal) Notes I Westchester Country Day School Schools Schools with Cafeteria,Gym and Showers �l 15 gal/student 15 430 students 6,450 7 6,450 PROPOSED SEWER FLOWS Type of Establishment Gallons Area(so Seats Employees Other Units Daily(gal) Days Per Average AnnualNotes Week Daily(gal) ' Westchester Country Day School Schools Schools with Cafeteria 12 gal I student -3 430 students -1,290 7 -1,290 Note#1 Fieldhouse(Concessions)-Used 2 days per week for weekend tournaments separate from school enrollment Food and Drink Facilities Specialty Food Stand or Kiosk 50 gal/100 sq.ft.floor space 50 243 122 2 35 Note#2 Fieldhouse(Restrooms)-Used 2 days per week for weekend tournaments separate from school enrollment Parks,Recreation and other Outdoor Activity Facilities Parks with Restroom Facilities 250 gal plumbing fixture 250 14 fixtures 3,500 2 997 Finch Gymnasium-Used 2 days per week for weekend tournaments separate from school enrollment Sports Centers Gymnasium 50 gal 1100 sq.ft 50 7,000 3,500 2 997 Note#3 Performing Arts Center-Used 1 day per week for productions separate fmm school enrollment Stadiums,Auditoriums,Theaters Community Centers 5 gal/seat 5 516 2,580 1 368 Design Flow Rate Increase: 1,107 gpd (46 gph) Total Flow Rate: 7,557 gpd (Exist.+Prop.) (315 gph) 1)The Cats Den gynn ium will be converted to a dining hall. Locker room and showers will be eliminated. After renovation,there will be no showers in either old or new gymnasiums,thereby allowing a flow reduction(credit)from 15 gpd/student to 12 gpd/student 2)Gross floor area of Fieldhouse building measures 1,820 sq.ft.,actual concessions area measures 243 sq.ft.,remaining area consists of restrooms, breezeway and storage. 3)Gross floor area of Finch Gymnasium building measures 15,947 sq.ft..,actual gymnasium area measures 7,000 sq.ft.,remaining area consists of locker rooms,curdle room,and class rooms. P:Wctive Projects\WGM\Westchester 18097\Engineering\Calculations\Waste Water Flow\18097-SS FLOW CALC.xls State of North Carolina Department of Environmental Quality VW4 Division of Water Resources €St4robs� of blister itesnrres Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Westchester County Day School Project Name for which flow is being requested: Westchester County Day Schl Expansion More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Willow Creek WWTP b. WWTP Facility Permit#: NC0034452 Ali flows are in MGD c. WWTP facility's permitted flow .080 d. Estimated obligated flow not yet tributary to the WWTP 0.00 e. WWTP facility's actual avg. flow 0.041 f. Total flow for this specific request 0.001107 MGD g. Total actual and obligated flows to the facility 0.0421 h. Percent of permitted flow used 53% 11. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, i Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm/pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow,MGD MGD Flow Capacity*** LS#3 Unknown 0.1397 0.0559 0.0134 0.001107 .0145 .0414 LS#1 Unknown 0.2016 0.0806 .0547 0.001107 0.0558 0.0248 *The Firm Capacity(design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. **Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf)not less than 2.5,per Section 2.02(A)(4)(c)of the Minimum Design Criteria. ***A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is<0. Downstream Facility Name (Sewer): Willow Creek-HP Collection System Downstream Permit Number: Un Known Page 1 of 6 FTSE 10-18 III. Certification Statement: I Micahel A. Melton certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. II Y cl fP . " , 06/13/2019 S:�ingOfficial Signature Date Aqua NC, Inc. Engineering Manager Title of Signing Official I i I I Page 2 of 6 FTSE 10-18