Loading...
HomeMy WebLinkAbout20161069 Ver 2_C503 6-19-17_20190108c 0 U E 0_ lt 0 N, ti 0 N 6i c co 0 U 0) c 00 z U) U 0 WE 0 U) c 0 U 10 THRUST BLOCK DIMENSIONS PIPE DIAMETER TEE CROSS 90 45 WYE 22 1/2 A B A B A B » 4 » 12 » 12 12 " » 12 12 » 12 6" 12" 12" 12" 12" 12" 12" 8" 15" 24" 12" 18" 12" 12" 10" 18" 24" 18" 18" 12" •� 12" -Se 30" 18" 24" 18" 12" � � B * d LINE MATERIAL OPE:]E AS SCHEDULED CV �� a -POST INDICATOR VALVE WITH LINEGUARD TYPE III DETECTABLE U N U TAMPER SWITCH BY ACIPCO (OR UNDERGROUND MARKING TAPE Z 2' SQ x 6" THICK o EQUAL) (6" WIDE TAPE) (VERIFY STD •U) aj CLASS B CONCRETE PAD 'o PRINTING AND APWA COLOR SCHD 40 PVC & CAP TO 5 ' LOCODES _ SLOPE SLOPE ) OUTSIDE OF BUILDING Q � � > VALVE BOX TO SUIT VALVE —� FINISHED SURFACE GRADE SUBGRADE ELEV z }, � v a ° AND DEPTH OF BURY - - - - - - -III-III % �� - - �° BLDG WALL O III=III-III =T=1 Q I � DUCTILE IRON a 11- I I- 1=1 1=1 - _ Illi III III= -III- w > D EXIST EARTH OR STRUC SEWER COVER REF SCHED. LINE FITTING ° a TI�_III II IIIIIIIIII o � o FILL AS APPLICABLE — ° FITTING w/ (2) 45 TAMP BACKFILL ADJUST TOP SECTION TO FINISH GRADE w O INDICATOR POST Y = c� v -SLOPE SIDEWALLS OF FIFE FIN GRADE CONNECT BY BLDG PLUMB. CONTR. REF BLDG. PLUMB. 4-aWRAP BARS EMBEDDED IN CONCRETE a N m EXCAVATION AS REQUIRED 5' NOMFOR CONT. * III --III II-III=III" = w o - 00 SDR 35 MORE THAN 5 +� U AS REQUIRED TO REACH UNDISTURBED SOIL -1T_I= -III-II III -III II-III VALVE BOX TO BE ENTIRELY -III- II III -II w o cnJ Q z � w OUTSIDE OF BUILDINGQD 0 THRUST BLOCK DIMENSIONS PIPE DIAMETER TEE CROSS 90 45 WYE 22 1/2 A B A B A B » 4 » 12 » 12 12 " » 12 12 » 12 6" 12" 12" 12" 12" 12" 12" 8" 15" 24" 12" 18" 12" 12" 10" 18" 24" 18" 18" 12" 12" 12" 24" 30" 18" 24" 18" 12" = II = SUPPORTED BY CONCRETE o �o w g TIGHTLY COMPACTED FITTINGS AS REQ'D. VALVE BODY-----III-III 11BLOCKS OR BRICKS TO z = CLEAN BEDDING SUIT. PVC MAIN CL200 AWWA C900 w Mr 45° RUNOUT ITI= III III -I m N CO N III=11 III =-III 11=III VALVE BOX MUST NOT BEAR SEE PLANS FOR PIPE SIZE -� ' � ��� WATER PIPE -----'ON VALVE OR PIPE. TRENCH WYE FITTING co N NON METALLIC PIPING 1= m rn WIDTH OR CONDUIT AS APPLICABLE =III REF TRENCH DETAIL ch I- =I I I -1m AS REQ D -III MAIN SEWER, REF SITE PLAN U w CONCRETE SUPPORT PAD CAPPED WYE �IIIIII� -_ (� * w -III-III-III-I (n C0 NOTE: 1 -III -III -III- n z W RESILIENT SEATED GATE VALVE, 200 PSI REQUIRED AT ALL WATER, SEWER, GAS, AND OTHER SEWER LATERAL `� 0 (D z SITE UTILITIES. 0 w INSTALLATION OF POST INDICATOR VALVE SHALL COMPLY WITH O Wz I- NFPA 96 AND ALL APPLICABLE STATE AND LOCAL CODES AND u.1 ORDINANCES W O c J N Q Q Q) Q X 2 �Z� 1 Thrust Block Gate Valve 3 Post Indicator Valve 4 Pi e Trench 5 Building Sewer Connection U) Y CO N.T.S. N.T.S. N.T.S. N.T.S. p N.T.S. o_ W 00 o� a U)CO NOTES: METER SET BY BLDG 4" X 24" X 24" X 2�" X 2�" QUAD FIRE NOTE: DOMESTIC GAS SHALL BE PRESSURE CONTRACTOR DEPARTMENT CONNECTION (FACE TOWARD 1. ALL HYDRANTS TO BE SET PLUMB W/NOZZLE FACING TESTED ® 90 PSI AND A MIN. OF 2 ~ HYDRANT) VERIFY SIZE REQUIREMENT AND STREET UNLESS OTHERWISE SPECIFIED BY FIRE E HOURS. ALL TESTING OF DOMESTIC GAS N I LOCAL FIRE DEPARTMENT THREADING DEPARTMENT 0 z HEAVY DUTY FRAME AND COVER SHALL BE WITNESSED BY GAS UTILITY. � N REQUIREMENTS AT HOSE CONNECTIONS THREADED PVC CLEANOUT PLUG (D O w � 2. ALL CONCRETE TO BE 2500 PSI P.C. CONCRETE W/LETTERS C.O. CAST IN COVER 0) 2E w SWING CHECK VALVE GRADE SURFACE AWAY FROM CLEANOUT 1 " IN GRASSY AREA 0 - o LOCK SET BY ~ PAINTED METAL 3. FIRE HYDRANT ASSEMBLY INCLUDES GATE VALVE AND 0" IN PAVED AREA U) BLDG CONTRACTOR RISER FIRE HYDRANT AS APPURTENANCES J GAS MAIN DOMESTIC GAS SPECIFIED BY CITY ADJUSTABLE HEAD FINISHED GRADE FINISHED SURFACE PROVIDE 2 SQUARE 4„ MIN. 2500 PSI P.C. GRADE @)X 6” THK. CONC. 12" 12" CONCRETE COLLAR III=1 I I=1 I I III=1 I I=1 I I=1 I I=1 I I=1 I I=1 11=1 11=1 1=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 I I 11=1 11=1 11= ��'��'� COLLAR ARo U N D NOTE: SEE APPLICABLE 1=III=III=11 11=III=III=III=III=III=III-III-Il1L III=III-III=III=III=III=III=III= III=III-I ALL VALVE BOXES FINISH GRADE DETAIL FOR BACKFILL AND o BEDDING INSTRUCTIONS. I II SIZE OF RISER PIPE PER LOCAL CODES /\/,\//�//\ \/i\/\/\ //i�/i//�/��/��/� r /\ r` I I III 45° BEND o METER RISER (AGA z o EPDXY COATED AND 6 CU. FT. GRAVEL VALVE BOX AS SPECIFIED BY CITY ° ° °° °° °I r7 o ° ° °° ° ° J/ �� °° a ° 000 ,> o 0°°0. oo °0 �� o ° APPROVED BY SITE w LINED RISER PIPE DRAIN -KEEP CLEAR 12 6 M.J. GATE VALVE CONTRACTOR OF CONCRETE » W/RETAINING GLANDS o z o° ° O °° %e�° o°o°° 1 CO 6D.I. ,o° o ° °° ° o 0o O°° ° 1 8 MIL POLYETHYLENE \ M.J. TEE - °° °°°° 00o DIRECTION OF FLOW °° ° DOMESTIC GAS (PE -2406) o -PVC MAIN CL200 AWWA C900 LINING BETWEEN : \\ - - BY SITE CONTRACTOR SEE PLANS FOR PIPE SIZE CONC. & DUCTILE _ . ... ;! /�•'� \/ OOoO°TAP & VALVE W/VALVE BOX BY IRON (TYPICAL) °o°o° TO FIRE SPRINKLER GAS UTILITY WYE° ° Q PLUG WYE IF SERVICE LATERAL GAS MAIN BY GAS UTILITY REFER TO THRUST REFER TO THRUST BLOCKING DOES NOT CONTINUE 2-1/2 X 24 X 24 BLOCKING DETAIL FOR RETAINING DETAIL FOR THRUST BLOCKING SEE PLAN FOR PIPE SIZE, 0 }' CONCRETE SUPPORT THRUST BLOCKING RETAINING GLAND REQUIREMENTS TYPE AND ELEVATION Q PAD REQUIREMENTS GLAND U I TE INSTALLATION OF FIRE DEPARTMENT CONNECTION SHALL COMPLY WITH NFPA CONCRETESUPPOR PROVISIONS AND ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. CONTRACTOR TO PROVIDE NON -FREEZE COMPONENT CONNECTION. c� L 6 Domestic Gas 7 Fire De Department Connection $ Fire Hydrant Assembly9 SanitarySewer Cleanout N.T.S. N.T.S. p N.T.S. N.T.S. INSTALL BRACKET SPACER AS REQUIRED. PROVIDED BY METAL BUILDING SUPPLIER z c li J o O Ln v w ui DOWNSPOUT PER BLOCK WALL M � a_ w ELEVATION z LL_J BUILDING DOWNSPOUT O Y w BLDG. 14" ^ 8" SCHED. 40 PVC PIPE - w WITH CAP CUT OUT FOR m U DOWNSPOUT. PAINT TO MATCH BUILDING DOWNSPOUT 3" Min / () VARIES ^ 1 1/2 DOWNSPOUT 1/2» DIA. MASONRY COMPACTED EARTH BACKFILL a a I ANCHORS o AT NON PAVED AREAS AND RON COMPACTED #57 STONE z ° °0 a 4 SPILL TO GRADE z° BACKFILL AT PAVED AREAS 00 4 » .l ° a PIPE SIZE AND SLOPE VARIES — — — — -� _ - SEE SHEET 0201 11=III=III=III=III= Elevation L6x3.5 STEEL ANGLE �1'�� � III=III III1 = III=III=III=III=1 I PER SIDE WELD TO , ° �V ,CAS COMPACTED EARTH BACKFILL w8x 1 o STEEL CHANNEL S III_1 I=III-1 AT NON PAVED AREAS AND IIIIIIIIII-III- -III=III=III=III=III a III=III=III=III COMPACTED #57 STONE IIIIIIIIIIII1 BEAM„ 3'-0" LONG - F FERNCO COUPLING 1=III=III=III=III=1 - 1 —o ABOVE GRADE _ _ �Ir �- a a III=III = CONTINUOUS FOOTING BACKFILL AT PAVED AREAS I=I I =I II I=I I = PVC PIPE �1�6 III -III- - I I I -I I I -I I I -I I I -I I BLDG. 1 =1 1=1 = I III=III=III III=III I IIIIIIIIII=III= NOTE: PROVIDE AT ALL DOCK/OVERHEAD DOOR LOCATIONS :'�ff°� III III -III- III III -III- III -III -III -III -II PAINT YELLOW (SEE SCHEDULE) - R-1 11 =H = 8" PVC SCHED - 40 -III-III 1=1 I I I -I I -I I -I I -I 11= RA SI ,- 1 _ _ - I =III=III=III=III=III I- LONG ELBOW SWEEP CONTINUOUS III=III=III=III = I III=III=III=III=II - 6' CURB r; III _ II—III = _—III—III—III- III—III III I , . III III III III- ° VERIFY SIZE AND PROFILE OF DOWNSPOUT WITH METAL BUILDING =I IIIIIIIIIIIIIIING II _ - 8"� CPP -CONNECT INTO MAIN _ III -III -III -III -III -I I a ° SUPPLIER PRIOR TO INSTALLATION TO ENSURE ADEQUATE CLEARANCE Drawn By CDB 1 �- - I=III-III-III-I -III-III-I I 1 -III PIPE AS REQ'D TO MAINTAIN MIN. -III = I=I I III -III -III -III= a CONCRETE I—III—III—I — HI -Q DRAIN PIPE (OR APPROVED SLOPE OF .5% III=III=III = a a =III=III=III= I Checked EJB EQUIVALENT) SEE GPI FOR SIZE III I II I—II ° IIIIIIIII—III- SPILL TO GRADE SLOPE MIN. OF 0.5%.IIIIII—III—III IIIIIIIIIIII THROUGH CURB LINE 11 Approved EJB -III-III-III-I I � � III -III -III -III= Downspout .lob No. 217045 Section 1=1 11=1 1=1 1=1 11=1 11=1 1=1 11=1 11=1 1=1 11=1 Plan N.T.S. 6-19-17 Scale Date APPROVED BY PURCHASER / TENANT DATE Roof Drain 10 10b Roof Drain APPROVED BY DEVELOPER / SELLER DATE C503 N.T.S. N.T.S. Sheet No.