HomeMy WebLinkAbout030001_Technical Correction_20180116Division of Water Resources � ❑ Division of Soil and Water Conservation ❑ Other Agency Facility Number: 030001 Facility Status: Active Inpsection Type: Technical Assistance Reason for Visit: Other County: Alleghany Date of Visit: 01/16/2018 Entry Time: 12:45 pm Exit Time: 1:15 pm Farm Name: Gambill & Gambill Farm Owner: David T Gambill Mailing Address: 305 Gambill Rd Physical Address: 305 Gambill Rd Facility Status: 0Compliant ❑ Not Compliant Location of Farm: Permit: AWC030001 ❑ Denied Access Inactive Or Closed Date: Region: Winston-Salem Incident # Owner Email: Igambill@skybest.com Phone: 336-372-2819 Sparta NC 28675 Sparta NC 28675 Integrator: Latitude: 36° 33' 20" Longitude: 81 ° 10' 34" From Sparta take 21 N to 221 S, then take right onto 93W to Elk Creek Church. Turn right on Farmers Fish Camp Road. Go about 2 1/2 miles. Turn right at Gambill Dairy sign. Question Areas: E Dischrge & Stream Impacts Waste Col, Stor, & Treat Certified Operator: David T Gambill Secondary OIC(s): Operator Certification Number: 22600 On -Site Representative(s): Name Title Phone 24 hour contact name David Gambill Phone On -site representative David Gambill Phone Primary Inspector: Meliss Rosebrock Phone: �.330 -7-Ito ' ` 9 Inspector Signature: �(�I Adll►� 1_,& Date: Z G Secondary Inspector(s): Rebecca D Chandler Inspection Summary: Today's visit was to check on the construction progress of the new dry waste structure. The dry stack and barn are to be under roof and constructed where the milk parlor and barn once stood. The area has been surveyed and graded. No other construction has occurred. No animals are being kept on the concrete lot at this time. No water quality violations or concerns were observed. Owner has over 100 beef cattle but they are on pasture until the barn and dry stack are built. Owner has been waiting on a revised design from the contractor that will meet NRCS approval. Per Mr. Gambill the section where the waste is to be stored needs a design with posts only 8 foot apart, rather than 12 foot as was in the original design. The rest of the barn (where cattle will housed) will have posts 12 foot apart. Mr. Gambill stated that he had just been informed by the contractor that the revised design had been sent to NRCS yesterday and that he has workers ready to begin construction immediately once given approval. If weather conditions were ideal, Mr. Gambill said he was told by the contractor that the dry stack could be built in about 5 weeks. page: 1 r F, Permit: `}AWC030001 Owner - Facility : David T Gambill Facility Number: 030001 Inspection Date: 01/16/18 Inpsection Type: Technical Assistance Reason for Visit: Other �n Regulated Operations Design Capacity Current promotions Cattle Cattle - Beef Feeder 200 0 Total Design Capacity: 200 Total SSLW: 160,000 Waste Structures Disignated Observed Type Identifier Closed Date Start Date Freeboard Freeboard Waste Pond WASTE POND 07/22/17 Discharges & Stream Impacts Yes No Na No 1. Is any discharge observed from any part of the operation? ❑ 0 ❑ ❑ Discharge originated at: Structure ❑ Application Field ❑ Other ❑ a. Was conveyance man-made? ❑ 1111 ❑ b. Did discharge reach Waters of the State? (if yes, notify DWQ) ❑ ❑ ❑ ❑ c. What is the estimated volume that reached waters of the State (gallons)? d. Does discharge bypass the waste management system? (if yes, notify DWQ) ❑ ❑ ❑ ❑ 2. Is there evidence of a past discharge from any part of the operation? ❑0 ❑ ❑ 3. Were there any observable adverse impacts or potential adverse impacts to Waters of the ❑M ❑ ❑ State other than from a discharge? Waste Collection. Storage & Treatment Yes No Na No 4. Is storage capacity less than adequate? ❑ ❑ ❑ If yes, is waste level into structural freeboard? ❑ 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ large ❑ ❑ ❑ trees, severe erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a ❑ ❑ ❑ waste management or closure plan? 7. Do any of the structures need maintenance or improvement? ❑ ❑ ❑ 8. Do any of the structures lack adequate markers as required by the permit? (Not applicable ❑ ❑ ❑ to roofed pits, dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ 01111 maintenance or improvement? page: 2