Loading...
HomeMy WebLinkAboutSW6190503_2017.0643 Rainbow Spout Springs NC PLANS_7/25/20192" REBAR FND. �IN,\ N: 0.00' 0.00' } U / } } } } } 18 16 6 } % 16A / C 7 REBAR F�' 0.00' o / QQ- } Al Rv 21 16 12" RCP INV. 329.84 SITE DIMENSION PLAN N29*43'16"E N60°16'43"W STORM RIM 333.59 NW 12" RCP INV. 332.47 GRAPHIC SCALE EXISTING 100' FEET OVERHANG UTILITY EASEMENT HARNETT COUNTY NOTES "THIS DEVELOPMENT IS WITHIN THE FIVE MILE MILITARY CORRIDOR OVERLAY ZONE, AND MAY BE SUBJECT TO MILITARY TRAINING ACTIVITIES." "NC 24-87 IS ON THE HARNETT COUNTY COMPREHENSIVE TRANSPORTATION PLAN" / / / / SANITARY RIM 334.36 NE 8" PVC INV. 324.71 BEGIN RUN I ■ ■ TRAFFIC CONTROL & SIGNAGE O1 DIRECTIONAL ARROW C4 (TYP.) O HANDICAP PAVEMENT SYMBOLS C4 (TYP.) O3 HANDICAP SIGN 13 C4 O4 24" WIDE WHITE STOP BAR (TYP.) O5 PAVEMENT STRIPING (4" WHITE) (TYP.) O 4" DOUBLE YELLOW LINE O7 30" STOP SIGN (R1-1) O MONUMENT SIGNAGE -ONLY SHOWN AS REFERENCE, IT WILL BE PERMITTED AND SUPPLIED BY A SEPARATE VENDOR - ALL TRAFFIC CONTROL SIGNAGE SHALL CONFORM TO "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" BY THE U.S. DEPARTMENT OF TRANSPORTATION, FEDERAL HIGHWAY ADMINISTRATION. - WORK DONE WITHIN CENTENNIAL PARKWAY R.O.W. SUBJECT TO NCDOT REVIEW AND APPROVAL. SITE NOTES El 16 HANDICAP RAMP C4 SIDEWALK RAMP 9 C4 �3 VALLEY GUTTER 18 C4 �4 6" CURB 5 (TYP.) C4 ❑5 MONOLITHIC CURB AND SIDEWALK 6 C4 lfl CONCRETE SIDEWALK $ C4 -) El DUMPSTER ENCLOSURE 1 C4 lfl CONCRETE APRON 7 C4 BOLLARD 4 C4 10 ASPHALT PAVEMENT 10 C4 11 RAIN GARDEN 12 DRAINAGE STRUCTURES 13 TRANSFORMER PAD 14 LIGHT POLE 15 BIKE RACK 1 C1 16 5' HIGH BLACK VINYL COATED CHAIN LINK FENCE (TYP) 16A FENCE GATE 17 PROPOSED RETAINING WALL (TO BE DESIGNED BY OTHERS) 18 PLAY GROUND EQUIP. WITH SOFT SURFACE AREA SHOW HEREON BY OTHERS, REMAINING PLAY AREA INSIDE FENCING TO BE SOD (REFERENCE SHEET LI.) EXTERIOR RECTANGLE REPRESENTS SUB -CUT LIMITS, 19 HVAC ENCLOSURE W/4' HIGH BLACK VINYL COATED CHAIN LINK FENCE (TYP) 15 20 DETECTABLE WARNING C4 21 SPLASH PAD WILL CONSIST OF 4" THICK CONCRETE SLAB W/SUMP IN THE CENTER. LAYOUT NOT SHOWN HERE, FOR CLARITY COORDINATE W/OWNER 22 ABOVE GROUND GAS TANK. FOR SPECIFIC EQUIPMENT SIZE/TYPE PLEASE REFER TO ARCHITECTURAL PLAN SET. 23 24' CROSS ACCESS EASEMENT REFER TO SHEET CO FOR GENERAL NOTES, SPECIFICATIONS, AND LEGENDS, IN ADDITION TO SITE -SPECIFIC NOTES AND REQUIREMENTS. lbffERPLAN..l ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT P-0215 604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 SEAL; THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. oQ,�N CA/3�< ..-oF�Jb4�"-V�igned Q by Stu�ar# gSA,pM5erson 04Ui�: 201 c � -04'00 A. A STUART ANDERSON, P.E. N.C. REG. #040659 0917Zo [] 7_�ia.� \���oPe,UHITECTVg9lC�C� ; 51613 '0'L�9TH 4<ANDO, 10 6-27-19 NCDEQ COMMENTS 9 4-29-19 UTILITY COMMENTS 3 6-11-18 COUNTY COMMENTS 2 5-8-18 COUNTY COMMENTS 1 2-15-18 QA/QC NO DATE REMARKS REVISIONS I<INDERCARE LEARNING CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 PROJECT NO; 201 7.0643 DATE; 2/12/18 cl SITE DIMENSION PLAN CHECKED; DM DRAWN; JFH U RETAINING WALL (DESIGN BY OTHERS) INTERPLAN SITE GRADING PLAN 15" THICK NCDOT CLASS "A" RIPRAP " REBAR FND. PAD 1 "= 20' EXIST. GRADE NTS ■ ■ ■ 15" THICK NCDOT CLASS "A" RIPRAP PAD CONTROL ELEV. 330.00 ORIPRAP APRON DETAL EDGE OF PAVEMENT 4.54.5' AA---I--11A PROVIDE EROSION PROTECTION AT END 6» 5' [6„ OF FLUME (CRUSHED CONCRETE OR RIP RAP) OCURB FLUME 0 i•»r_lII 6" 59 6" Ll 9"r 6"j SECTION A -A ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT P-0215 604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. �N CARp', 90, �yg:ned _ Q by StLiat# SAhdersor / 04@a: _ 2019.07•:e.- NTS Gy �N�flr'00' ' A. AN�� TOE OF SLOPE/BOTTOM OF SWALE WALL (TO BE DESIGNED BY OTHERS) ELEV. . 330.00 NTS DRG015.DWG NTS STUART ANDERSON, P.E. N.C. REG. #040659 CORPORATE SEAL: "'01 1 11 1111/ "', ?,PLAN, A �� oPeUHITECTVR• <0' 51613: R<gNp,III it 10 6-27-19 NCDEQ COMMENTS 9 4-29-19 UTILITY COMMENTS 8 8-8-18 HCDPU COMMENTS 2 6-11-18 COUNTY COMMENTS NO DATE REMARKS REVISIONS KINDERCARE LEARNING CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 PROJECT NO: 2017.0643 DATE: 2/12/18 C3 SITE GRADING PLAN CHECKED: DM DRAWN: JFH U NOTE: FABRICATED FITTINGS ARE AVAILABLE IN TEES, WYES, REDUCERS, 450 BENDS. WATERTIGHT (Wi) JOINTS SHOWN. SOIL -TIGHT (ST) FITTINGS ARE ALSO AVAILABLE. BUILDING FACE NYLOPLAST CLEANOUT END CAP ADJUST GRADE PER ENGINEERS DOWNSPOUT ADAPTER / , > PLAN INSERTED IN RISER IN 3? PIPE FINISHED GRADE •� �• ` FABRICATED HDPE ST DBL. MITER 900 «• • • ••' BEND FABRICATED HDPE ST ' ,j^. • i 45° WYE ., INSERT INJECTION MOLDED, FABRICATED HDPE • '�: � ' • j' GASKETED SPIGOT BY ST DBL. MITER 900 BELLREDUCER BEND •° Wi BELL -BELL `• , COUPLER(TYP) �..��. • •t '• ti. � EL. 334.50 EL. 334.50 d d b d 4 a 3"x6" RECT. I I ORIFICE RETAINING WALL TO BE DESIGNED BY I d EL. 333.25 a OTHERS d 3" 0 u. ° d ORIFICE EL. 331.00 12" HDPE EL. 330.00 �2t 49� ° d EL. 329.50 'd . d °'° d . d ed, . c` FILL WITH GROUT ° RIPRAP APRON HDPE PIPE (TYP.) •'+•j i• - TO EL. 330.00 SEE DETAIL "B" 14 // \ PLAN VIEW FRONT VIEW SIDE VIEW SHEET C3 28 D DOWNSPOUT AND CONNECTION NTS 41 / I� �v 24 OUT ILL CONTROL STRUCTURE (CS-1) NTS = ��h � � � � \ / k 7 3 <<q 16 , 26 / �� � / �op�^mac a d21 00 • r 12 2 \ ° 26 19 25 °. \ d \�\ 18 27 Al 25 25 11 d a.' d\ 29 d 26 � �, .. 25 Cyf 25 V �l QjO 25 27 D A)) • �� • ° I /\\ D. Q A�) \ 4 25 10 d `V 25 t 25 I � 33, 195� da . 26 ° a.. 25 2 � a \ 26 9 3 d a 25 \ u � d Q �s0 4 d Ll d I L rl%ur, IIV V. JLZj.O`t NORTH 20 0 20 40 GRAPHIC SCALE SITE DRAINAGE PLAN STORM RIM 333.59 NW 12" RCP INV. 332.47 1 "= 20' � 7 REFER TO SHEET CO FOR GENERAL NOTES, SPECIFICATIONS, AND LEGENDS, IN ADDITION TO SITE -SPECIFIC NOTES AND REQUIREMENTS. BURIED LMLMES NOTE BURIED UTILITIES ARE SHOWN AT THEIR APPROXIMATE LOCATION BASED UPON INFORMATION OBTAINED FROM UTILITY COMPANIES AND FIELD EVIDENCE. OTHER BURIED UTILITIES MIGHT EXIST ON THE SUBJECT SITE WHICH ARE NOT SHOWN ON THIS DRAWING. USE EXTREME CAUTION DURING EXCAVATION PROCEDURES AND CONTACT NORTH CAROLINA 811. DIAL 811 OR 1-800-632-4949 FOR EXACT LOCATION OF BURIED FACILITIES PRIOR TO EXCAVATION OPERATIONS. DRAINAGE STRUCTURE TABLE INTERPLAN INLET #1 NYOPLAST YARD DRAIN ARCHITECTURE GRATE ELEV. = 333.50 ENGINEERING INV ELEV. (SE) = 331.55 INTERIOR DESIGN 52 LF 12" HDPE @ 0.43% PROJECT MANAGEMENT �3 INLET #2 P-0215 NYOPLAST YARD DRAIN GRATE ELEV. = 333.50 INV ELEV. (NW) = 331.33 604 COURTLAND STREET INV ELEV. (SE) = 331.33 SUITE 100 4❑ 60 LF 12" HDPE @ 0.43% ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 INLET #3 NYOPLAST YARD DRAIN SEAL: GRATE ELEV. = 333.50 THIS DOCUMENT IS "NOT FOR CONSTRUCTION" INV ELEV. (NW) = 331.07 UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. INV ELEV. (SE) = 331.07 83 LF 12" HDPE @ 0.31 % ; ` ` �N CAR �7 STORMWATER MANHOLE #1 �Q�o I.-y�l�ne by Start ST YARD DRAIN 04 GRATE 8� g GRATE ELEV. = 333.50 rsotl U {' INV ELEV. (NW) = 330.81 INV ELEV. (NE) = 330.81 =,�(�' .F,VG20�07 A. A �8 68 LF 12" HDPE @ 0.38% 9❑ INLET #4 STUART ANDERSON, P.E. STORMWATER INLET N.C. REG. #040659 GRATE ELEV. = 334.98 INV ELEV. (NE) = 330.55 CORPORATE SEAL: INV ELEV. (SW) = 330.55 INV ELEV. (NW) = 330.55 �ApLAN 10 86 LF 18" HDPE @ 0.21 % oPPGHITECT�g9lc`OO 11 INLET #5 _ 51613 STORMWATER INLET = GRATE ELEV. = 334.72 INV ELEV. (SW) = 330.37 �% ' ....... INV. ELEV. (NE) = 330.37 ''�R�AND0, INV. ELEV. (NW) = 330.37 12 119 LF 18" HDPE @ 0.25% 13 INLET #6 STORMWATER INLET GRATE ELEV. = 334.49 INV ELEV. (SE) = 330.68 INV. ELEV. (SW) = 330.68 14 63 LF 18" HDPE @ 0.40% 15 MES INV. EL. 330.00 16 17 LF 10" HDPE @ 1 % 17 INLET #7 STORMWATER INLET i GRATE ELEV. = 333.50 AINV ELEV. (SW) = 330.25 18 16 LF 18" HDPE 0 0.21% 19 STORMWATER MANHOLE #2 RIM ELEV. = 334.90 INV. ELEV. (SW) = 330.33 INV. ELEV, (N) = 330.33 20 31 LF 18" HDPE @ 0.21 % 21 CONNECT TO STORM DRAINAGE CHAMBERS AT EL. 330.25 21A UNDERGROUND RETENTION SYSTEM (SEE SHEET C3.3) 22 10" MES INV. 333.50 10 6-27-19 NCDEQ COMMENTS 9 4-29-19 UTILITY COMMENTS 23 15 LF 10" PVC 8 8-8-18 HCDPU COMMENTS 5 6-25-18 NCDEQ COMMENTS Z NO DATE REMARKS 24 OUTFALL CONTROL STRUCTURE C3. REVISIONS 1 25 CONNECT TO BUILDING @ ELE. 332.00 PER DETAIL ON THIS SHEET 26 8" PVC 0 MIN 1.0% SLOPE v v 27 8" CLEAN OUT I 28 15 LF SPREADER SWALE ,UnderCaw LEAJMMG CENTERS 29 CONNECT TO SPLASH PAD nde are AT INV. 332.00 NOR U C A r 1 30 119 LF 18 HDPE @ 0.25% KINDERCARE NOTE: LEARNING CENTER CONTRACTOR SHALL FIELD VERIFY LOCATION, INVERT ELEVATION, MATERIALS AND PIPE SIZE BEFORE CONSTRUCTION BEGINS. C-PROTOTYPE CONTRACTOR SHALL BEGIN STORMWATER PIPING CONSTRUCTION AT 95 CENTENNIAL PARKWAY THE POINT OF CONNECTION OF EXISTING STORMWATER SYSTEM. WHEN ANY ROOTS OR EXISTING TREE ARE ENCOUNTERED DURING SPOUT SPRINGS, NC 28326 LAND CLEARING AND/OR GRADING OF THE SITE, THE ROOTS MUST BE CUT OFF EVENLY WITH CLEAN SHARP PRUNING TOOLS. THE PROJECT NO; 2017.0643 CONTRACTOR/DEVELOPER SHALL MINIMIZE THE DAMAGE TO EXISTING DATE; 2/12/18 TREE ROOT SYSTEMS. C3ml SITE DRAINAGE PLAN � OL I E CHECKED; DIV DRAWN; JFH INTERPLAN 30"0 BULKHEAD Cl 30"0 BULKHEAD D1 30"0 BULKHEAD E1 30"0 BULKHEAD F1 30"0 BULKHEAD G1 STUB INFORMATION SYSTEM PIECE STUBINVERT INVERT 10" PJ STUB B2 331.00 33025 RISER INFORMATION SYSTEM PIECE RIM ELEV. INVERT 24"0 RISER J1 340.00 33025 126'-6" C K K K K D K K K K Q w A Q E K K K KCie m a `. w F K K K K o G K BAND, TYPICAL SEE DETAIL SHEET C3 K H J MAINTENANCE BASIN 25 6" 24" PJ RISER J1 29'-6" B 30" PJ Bl w/ 10" PJ THE UNDERSIGNED HEREBY APPROVES THE ATTACHED (#) PAGES INCLUDING THE FOLLOWING: PIPE STORAGE = 3,148 CF MAINLINE PIPE GAGE = 16 WALL TYPE = PERFORATED DIAMETER = 30" FINISH = ALT2 CORRUGATION = 2 2/3x1/2 CUSTOMER DATE PIPE STORAGE: 3,148 CF STRUCTURAL BACKFILL STORAGE: 1,747 CF TOTAL STORAGE PROVIDED: 4,895 CF LOADING: H2O PIPE INV. = 330.25 KEY 7 7� PERFORATED SOLID WEIR DETAIL NOT TO SCALE 331.50' NOTES LKHEAD B1 STUB B2 • ALL RISER AND STUB DIMENSIONS ARE TO CENTERLINE. • ALL ELEVATIONS, DIMENSIONS, AND LOCATIONS OF RISERS AND INLETS, SHALL BE VERIFIED BY THE ENGINEER OF RECORD (EOR) PRIOR TO RELEASING FOR FABRICATION. 5' • ALL FITTINGS AND REINFORCEMENT COMPLY WITH ASTM A998. • ALL RISERS AND STUBS ARE 22/3" x %z' CORRUGATION AND 16 GAGE UNLESS OTHERWISE NOTED. • RISERS TO BE FIELD TRIMMED TO GRADE AS REQUIRED, BY CONTRACTOR. • QUANTITY OF PIPE SHOWN DOES NOT PROVIDE EXTRA PIPE FOR CONNECTING THE SYSTEM TO EXISTING PIPE OR DRAINAGE STRUCTURES. OUR SYSTEM AS DETAILED PROVIDES NOMINAL INLET AND/OR OUTLET PIPE STUB FOR CONNECTION TO EXISTING DRAINAGE FACILITIES. IF ADDITIONAL PIPE IS NEEDED IT IS THE RESPONSIBILITY OF THE CONTRACTOR. • ALL ACCESS CASTINGS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE NOT SUPPLIED BY CONTECH. TM1e design and information shown on ibis drawing is provided �asaserice"the PROJECT No.: SEQ. No.: DATE: p,olect owner, engineer and contractor by Co.,ec1,zg.eered Solub.-LLC("Co.,e ). Neither ibis -` �\I� / I%_�ITCAIJ 30"0 PERFORATED UNDERGROUND RETENTION SYSTEM - 593240-010 593240 0,0 8/v2018 ( drawing, nor any part thereof, may be used, reproduced o, a modified in an m ,without the ,® written consent of , C .► NTECH . r-_w �� ,�` ` = = , 4 _ DESIGNED: DRAWN: t G..,ec h. xp,e emcomply isdo.e a„he use,'so-NIN and Con,ecM1 exp,esslY disclaims any liability or responsibibty for such.. ENGINEERED SOLUTIONS LLC CMP DETENTION SYSTEMS RAINBOW CHILD CARE CENTER (SPOUT SPRINGS) DRA AGB panties vv von w l,ed, be,vmen,M1esu liedi.mrma,ionu www.ContechES.com CONTECH CAMERON, NC CHECKED: APPROVED: [_ me draw;. is basetl and actual fieldco.ditions are encountered g .ed s site work ro sses ,M1ese discre antes must be re r,ed Sa v g,e v vn 7037 Ridge Road, Hanover, MD 21076 CONTRACT � DRA DRA ,oCo.,ecM1 immedia,efy fo„esval. a,io. o„M1e design Co.,ecM1 866-740-3318 410-796-5505 866-376-8511 FAX DRAWING SITE DESIGNATION- D S NATI N: UG S G O SHEET NO.. ac cc ei.i�bimaio.rappgliedbyome,s'nssing, incomplete or AR DATE REVISION DESCRIPTION BY Cl I of 4 CONNECTION DETAIL 7 1/2" TECHCO SHOWN - MAY VARY TECHCO BAND ANGLES 1/2" DIA. BOLT RISER EXTENSION FLAT BAND SHOWN, MAY VARY (NO GASKET) MAINLINE PIPE WELEVATION VIEW OF CMP & RISER ED 0 0 F f� to - 0 N PLAIN END CMP RISER PIPE GENERALNOTES: 1. DELIVERED BAND STYLE AND FASTENER TYPE MAY VARY BY FABRICATION PLANT. 2. JOINT IS TO BE ASSEMBLED PER AASHTO BRIDGE CONSTRUCTION SPECIFICATION SEC 26.42.4. 3. BAND MATERIAL AND GAGE TO BE SAME AS RISER MATERIAL. 4. IF RISER HAS A HEIGHT OF COVER OF 10' OR MORE, USE A SLIP JOINT. 5. BANDS ARE NORMALLY FURNISHED AS FOLLOWS: • 12" THRU 48" 1-PIECE • 54" 2-PIECES 6. ALL RISER JOINT COMPONENTS WILL BE FIELD ASSEMBLED. 7. MANHOLE RISERS IN APPLICATIONS WHERE TRAFFIC LOADS ARE IMPOSED REQUIRE SPECIAL DESIGN CONSIDERATIONS. 8. DIMENSIONS SUBJECT TO MANUFACTURING TOLERANCES. 12" RISER BAND DETAIL NOT TO SCALE 12-1/8.. 10-1/4" HUGGER SINGLE BAR, BAND BOLT &STRAP (SBBS) ffmCC� �I I �111 I I I I I I CI NO GASKET CONNECTION DETAIL (SBBS) 2 2/3"x1/2" RE -ROLLED END HEL-COR PIPE GENERAL NOTES: 1. JOINT IS TO BE ASSEMBLED PER AASHTO BRIDGE CONSTRUCTION SPECIFICATION SEC 26.42.4. 2. BAND MATERIALS AND/OR COATING CAN VARY BY LOCATION. CONTACT YOUR CONTECH REPRESENTATIVE FOR AVAILABILITY. 3. BANDS ARE SHAPED TO MATCH THE PIPE -ARCH WHEN APPLICABLE. 4. BANDS ARE NORMALLY FURNISHED AS FOLLOWS: • 12" THRU 48" 1-PIECE • 54" THRU 96" 2-PIECES • 102" THRU 144" 3-PIECES 5. BAND FASTENERS ARE ATTACHED WITH SPOT WELDS, RIVETS OR HAND WELDS. 6. ALL CMP IS REROLLED TO HAVE ANNULAR END CORRUGATIONS OF 2-2/3"x,/2" 7. DIMENSIONS ARE SUBJECT TO MANUFACTURING TOLERANCES. 8. ORDER SHALL DESIGNATE GASKET OPTION, IF REQUIRED (SEE DETAILS ABOVE). H-12 HUGGER BAND DETAIL NOT TO SCALE The design and information shown on this drawing is provided -ce,o t prolec, owner, engineer and contractor by Conte hEnginee,ed SOluhons LLC ("Con,ecM1"). Nei,M1er,M1is drawing, nor anv p .t thereof, may be used, reproduced or moaiNea i. anv manner wi,M1o., the v,e, written co.sem of G..-hFaimraI. yd-I.-..yeaubeuserp.-NIskam Co.,ech exp,esslY disdaims anY babibty or resposibility for # # # # _` /' �y\I�/ C ��►,NTECH ENGINEERED SOLUTIONS LLC A��I%uTCAIJ �-_ �,,►,�` `_ CMP DETENTION SYSTEMS 30" PERFORATED UNDERGROUND RETENTION SYSTEM - 593240-010 RAINBOW CHILD CARE CENTER (SPOUT SPRINGS) PROJECT No.: 593240 SEQ. No.: 010 DATE: 8n/zo,8 # # # # DESIGNED: DRA DRAWN: AGB # # # # -1, u-. CONTECH CONTRACT DRAWING CAM E RO N N C SITE DESIGNATION: UGD CHECKED: DRA APPROVED: DRA I, discrepancies be,wee. the s.vvbea mm,matio..po. wmcn med,a is basedad-ual,etl-.daes are e.coume,ed s site work pmg,esses, these disc,eva.cesms, be,epo„ed ,o Co.,ech Immediate for re�valua,io. o .g, si .. Con,ecM1 M g �aemei�imbmzoompp9 byM e,s mssmg, mcomvle,e o, Com 7037 Ridge Road, Hanover, MD 21076 # # # # 866-740-3318 410-796-5505 866-376-8511 FAX SHEET NO.: C3 OF 4 AR DATE REVISION DESCRIPTION BY i c i LIMITS OF REQUIRED BACKFILL 12" SEE TYPICAL BACKFILL DETAIL NOTES TYPICAL SECTION VIEW NOT TO SCALE 2 2/3" x 1/2" CORRUGATION - STEEL AND ALUMINUM CMP EDGE SPACING EQUAL ON BOTH SIDES 0 0 0 0 o typo 0 0 0 o 0 o o 0 TYP. D r COIL WIDTH ~ OPEN AREA = 3.76 SQ. IN. / L.F. NOTE: ALL HOLES ARE 3/8" DIAMETER AND ARE NOTED AS "CLASS 2 PERFORATIONS" PER AASHTO M 36 AND ASTM A760, B745. EXFILTRATION AREA STANDARD PERFORATION PATTERNS APPROXIMATE AREA PER LINEAR FOOT OF PIPE CORRUGATION PATTERN PIPE 2 2/3" x 1/2" 3" x 1" 5" x 1" ULTRA FLO 30" PJ 29.5 SQ. IN. 32.7 SQ. IN. 32.3 SQ. IN. NOTES- 1 - GAGE AND COATING LIMITATIONS APPLY. 5" x 1" IS NOT AVAILABLE IN ALUMINUM. 2. ALL DIMENSIONS ARE SUBJECT TO MANUFACTURING TOLERANCES. TYPICAL PERFORATION DETAIL TM1e design and information show. on drawing is provided e to ,he prolec, owner, engineer and c Ne,acmr ,y d,.,.g, ngin.y tffie f,LLC ("Co.,ech"). Neimer,M1is drawing, nor anv va„ mereo,, may be sea, rev,oa.cea o, mom,ea i. anv manner wamm me p-, written consent of Co., 1, FZII.,eI.-ply is done a, the user's own risk and Co0ec1, ex p,esslr d isclai ins any liability or ,espo.s NIN, for If discrepancies been the suppled information upon winch the drawing is based and actual field -.6-are encountered s site work progresses, these discrepancies must be reported to Con,ec1, immediately for r­ua,an of,M1e desgn_ Con,ec1, cepis.o Iiabihly for desgns based on missing, incomple,e or carafe information app- by others TEMPORARY COVER FOR CONSTRUCTION LOADS HEIGHT OF COVER NOT TO SCALE C NTECH® ENGINEERED SOLUTIONS LLC www.ContechES.com 7037 Ridge Road, Hanover, MD 21076 CONTECH CONTRACT DATE REVISION DESCRIPTION BY 866-740-3318 410-796-5505 866-376-8511 FAX DRAWING FINISHED GRADE CONSTRUCTION LOADS FOR TEMPORARY CONSTRUCTION VEHICLE LOADS, AN EXTRA AMOUNT OF COMPACTED COVER MAY BE REQUIRED OVER THE TOP OF THE PIPE. THE HEIGHT -OF -COVER SHALL MEET THE MINIMUM REQUIREMENTS SHOWN IN THE TABLE BELOW. THE USE OF HEAVY CONSTRUCTION EQUIPMENT NECESSITATES GREATER PROTECTION FOR THE PIPE THAN FINISHED GRADE COVER MINIMUMS FOR NORMAL HIGHWAYTRAFFIC. AXLE LOADS PIPE SPAN, INCHES (kips) 18-50 50-75 75-110 110-150 MINIMUM COVER (FT) 2.0 2.5 3.0 3.0 12-42 48-72 3.0 3.0 3.5 4.0 78-120 3.0 3.5 4.0 4.0 126-144 3.5 4.0 4.5 4.5 "MINIMUM COVER MAY VARY, DEPENDING ON LOCAL CONDITIONS. THE CONTRACTOR MUST PROVIDE THE ADDITIONAL COVER REQUIRED TO AVOID DAMAGE TO THE PIPE. MINIMUM COVER IS MEASURED FROM THE TOP OF THE PIPE TO THE TOP OF THE MAINTAINED CONSTRUCTION ROADWAY SURFACE. CONSTRUCTION LOADING DIAGRAM NOT TO SCALE IINI I IHL I -ILL CINVCLUrr_ • BACKFILL REQUIREMENTS FOLLOW THE GUIDELINES OF AASHTO LRFD BRIDGE DESIGN (SEC 12) and CONSTRUCTION (SEC 26). 1 MINIMUM TRENCH WIDTH MUST ALLOW ROOM FOR PROPER COMPACTION OF HAUNCH MATERIALS UNDER THE PIPE. THE MINIMUM TRENCH WIDTH (12-6-6-1): PIPE<12.' D+16" PIPE > 12- 1.5D + 12" ,a MINIMUM EMBANKMENT WIDTH (in feet) FOR INITIAL FILL ENVELOPE (12.6.62): PIPE < 24- 3.0D PIPE 24" - 144- D + TO" PIPE > 144- D + 10'0" 2 THE FOUNDATION UNDER THE PIPE AND SIDE BACKFILL SHALL BE ADEQUATE TO SUPPORT THE LOADS ACTING UPON IT (26.5.2). 3 BEDDING MATERIAL SHALL BE A RELATIVELY LOOSE MATERIAL THAT IS ROUGHLY SHAPED TO FIT THE BOTTOM OF THE PIPE FROM SPRINGLINE OF PPE TO 4"-6" BELOW BOTTOM OF PIPE- 4 CORRUGATED STEEL PIPE (CSP) [HEL-COR]. 5 HAUNCH ZONE MATERIAL SHALL BE HAND SHOVELED OR SHOVEL SLICED INTO PLACE TO ALLOW FOR PROPER COMPACTION (26.5.4). 5a GEOTEXTILE SHALL BE USED IF REQUIRED BY ENGINEER TO PREVENT SOIL MIGRATION INTO VARYING SOIL TYPES. 5b BACKFILL PLACED ABOVE SPRINGLINE TO MEET AASHTO 145, A-1, A-2 OR A-3 CLASSIFICATION OR APPROVED EQUAL, COMPACTED TO 90 % STANDARD PROCTOR (T-99). MAXIMUM PARTICLE SIZE NOT TO EXCEED 3" (12.4.1.2). ALL LIFTS PLACED IN A CONTROLLED MANNER. IT IS RECOMMENDED THAT LIFTS NOT EXCEED AN 8" UNCOMPACTED LIFT HEIGHT TO PREVENT UNEVEN LOADING, AND THE LESSER OF 1/3 THE DIAMETER OR 24" AS THE MAXIMUM DIFFERENTIAL SIDE -TO -SIDE (26.5.4). 6 INITIAL BACKFILL ABOVE PIPE MAY INCLUDE ROAD BASE MATERIAL (AND RIGID PAVEMENT IF APPLICABLE). SEE TABLE ABOVE. 6a TOTAL HEIGHT OF COMPACTED COVER FOR CONVENTIONAL HIGHWAY LOADS IS MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT OR TOP OF RIGID PAVEMENT (12-6-6-3)- 7 FINAL BACKFILL MATERIAL SELECTION AND COMPACTION REQUIREMENTS SHALL FOLLOW THE PROJECT PLANS AND SPECIFICATIONS PER THE ENGINEER OF RECORD (26-5-4-1)- NOTES- FOR MULTIPLE BARREL INSTALLATIONS THE RECOMMENDED STANDARD SPACING BETWEEN PARALLEL PIPE RUNS SHALL BE PIPE DIA./2 BUT NO LESS THAN 12", OR 36" FOR PIPE DIAMETERS 72" AND LARGER. CONTACT YOUR CONTECH REPRESENTATIVE FOR NONSTANDARD SPACING (TABLE C12.6.7-1). TYPICAL NORTH CAROLINA BACKFILL DETAIL NOT TO SCALE PROJECT No.: SEQ. No.: DATE: 30" 0 PERFORATED UNDERGROUND RETENTION SYSTEM - 593240-010 593240 010 8/,/2018 RAINBOW CHILD CARE CENTER (SPOUT SPRINGS) DESIGNEDDRA DRAWN AGB CHECKED: APPROVED: CAMERON, NC DRA DRA SITE DESIGNATION: UGD SHEET NO.: C^ O 4 A 036" MAX., HS-25 ACCESS CASTING WITH GRADE RINGS AS REQUIRED, TO BE PROVIDED AND INSTALLED BY CONTRACTOR. MAYBE TOP MOUNTED CMP (AS SHOWN) OR RECESSED. It PROTECTION w SLAB RIM/FINISHED UO >_ GRADE VARIES 01- _ .'A GASKET MATERIAL O CMP RISER Q SUFFICIENT TO PREVENT a &. SLAB FROM BEARING ON F 0 RISER TO BE PROVIDED BY CONTRACTOR. OR 11"TYP. < i SPECIFICATION FOR CORRUGATED STEEL PIPE -ALUMINIZED TYPE 2 STEEL = SCOPE HANDLING AND ASSEMBLY THIS SPECIFICATION COVERS THE MANUFACTURE AND SHALL BE IN ACCORDANCE WITH RECOMMENDATIONS OF THE INSTALLATION OF THE CORRUGATED STEEL PIPE (CSP) DETAILED IN NATIONAL CORRUGATED STEEL PIPE ASSOCIATION (NCSPA) THE PROJECT PLANS. INSTALLATION ' MATERIAL SHALL BE IN ACCORDANCE WITH AASHTO STANDARD THE ALUMINIZED TYPE 2 STEEL COILS SHALL CONFORM TO THE SPECIFICATIONS FOR HIGHWAY BRIDGES, SECTION 26, DIVISION II 3 APPLICABLE REQUIREMENTS OF AASHTO M274 OR ASTM A929. OR ASTM A798 AND IN CONFORMANCE WITH THE PROJECT PLANS AND SPECIFICATIONS. IF THERE ARE ANY INCONSISTENCIES OR PIPE CONFLICTS THE CONTRACTOR SHOULD DISCUSS AND RESOLVE WITH THE SITE ENGINEER. THE CSP SHALL BE MANUFACTURED IN ACCORDANCE WITH THE APPLICABLE REQUIREMENTS OF AASHTO M36 OR ASTM A760. THE IT IS ALWAYS THE RESPONSIBILITY OF THE CONTRACTOR TO PIPE SIZES, GAGES AND CORRUGATIONS SHALL BE AS SHOWN ON FOLLOW OSHA GUIDELINES FOR SAFE PRACTICES. THE PROJECT PLANS. ALL FABRICATION OF THE PRODUCT SHALL OCCUR WITHIN THE UNITED STATES. i TM1e design and infor Vmation shown on ,M1is drawing is provkfed e,o tholec e p,t owner, engineer and c b-t., by C.-I,Engineered Solutions LLC("C 0-h"). Neither this draw;. art mereof, ,Danced o, 9. nor a.Yp Y be used ma , ep modifed in anY manner wimou,,he prior written consent of Co.:e'M1 Failure,dZ IP, isdy1, a,ibe use,'so-NIN and co.,ecb expressM disclaims anY babibty or responsibility, fb, s.cM1.-. If discrepancies be,vree. the suppled i. fo,ma,io. upon which the drawing ¢ basetl and actual field conditions are encountered s sae work progresses, these dlsmepa.cies muss be repo to Con,ecM1 immedia,elY fo„e-evai. ago. of meaesg._ -t-1, ceph,.o lability for designs based on missing, incomple,e o, u.e informa,ion applied by o,M1ers MATERIAL SPECIFICATION NOT TO SCALE # # # # # # # # # # DATE REVISION DESCRIPTION C:NTECH® ENGINEERED SOLUTIONS LLC www.ContechES.com 7037 Ridge Road, Hanover, MD 21076 866-740-3318 410-796-5505 866-376-8511 FAX REINFORCING TABLE "BEARING 0 CMP A 0 B REINFORCING PRESSURE RISER (PSF) 24 04'#5 26" @ 10" OCEW 2,540 4'x4' #5 @ 10" OCEW 1,900 30" PJ 4'-6" 32 #5 @ 10" OCEW 2,260 T-6" x 4'-6" #5 @ 9" OCEW 1,670 36" 05' 38 #5 @ 9" OCEW 2,060 5' x 5' #5 @ 8" OCEW 1,500 42 PJ 5'-6" 44 #5 @ 8" OCEW 1,490 5'-6" x 5'-6" #5 @ 8" OCEW 1,370 48" 06' 50" #5 @ T' OCEW 1,210 6 x 6' #5 @ T' OCEW 1,270 SECTION VIEW -ASSUMED SOIL BEARING CAPACITY ACCESS CASTING NOT SUPPLIED BY CONTECH O OA A O PJB '4 tom\ #4 DIAGONAL TRIK #4 DIAGONAL TRIM BAR (TYP. 4 PLACES) BAR (TYP. 4 PLACES), SEE NOTE 7 SEE NOTE 7. 2" COVER (TYP) J� R- L - ti GO Q1 OPENING II OPENING IN PROTECTIOI PROTECTION SLAB FOI SLAB FOR CASTIN( CASTING INTERRUPTED BAR REPLACEMENT, SEE NOTE 6. STANDARD STANDARD REINFORCING, REINFORCING, SEE TABLE SEE TABLE ROUND OPTION PLAN VIEW SQUARE OPTION PLAN VIEW INTERRUPTED BAR REPLACEMENT, SEE NOTE 6. NOTES: 1. DESIGN IN ACCORDANCE WITH AASHTO, 17th EDITION 7. TRIM OPENING WITH DIAGONAL #4 BARS, EXTEND AND ACI 350. BARS A MINIMUM OF 12" BEYOND OPENING, BEND BARS AS REQUIRED TO MAINTAIN BAR COVER. 2. DESIGN LOAD HS25. 8. PROTECTION SLAB AND ALL MATERIALS TO BE 3. EARTH COVER = 1' MAX. PROVIDED AND INSTALLED BY CONTRACTOR. 4. CONCRETE STRENGTH = 4,000 psi 9. DETAIL DESIGN BY DELTA ENGINEERS, ARCHITECTS AND LAND SURVEYORS, EN DWELL, NY. 5. REINFORCING STEEL = ASTM A615, GRADE 60. 6. PROVIDE ADDITIONAL REINFORCING AROUND OPENINGS EQUAL TO THE BARS INTERRUPTED, MANHOLE CAP DETAIL HALF EACH SIDE. ADDITIONAL BARS TO BE IN NOT TO SCALE THE SAME PLANE. 30" 0 PERFORATED UNDERGROUND RETENTION SYSTEM - 593240-010 593240 010 8nn8 _uT_cA■J ��,►,�` `= Ow IN DESIGNED: DRAWN: CMP DETENTION SYSTEMS RAINBOW CHILD CARE CENTER (SPOUT SPRINGS) DRA AGB CONTECH CAMERON, NC CHECKED: DRA APPROVED: DRA CONTRACT 1 SITE DESIGNATION- UGD SHEET NO.: DRAWING C4 OF 4 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT P-0215 604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. -\N CAR , �0�oFESdi�rt�sr0 ne e s LStuart S�y-N 04qerson = /L/I ; cn Date: z Gy 'FNGI 4T A"1 -04'0 ' �fffiii(,f� CORPORATE SEAL: ``` kO(if(,f�/ pPP"'TAE � RA<< 2 51613 or .0?o9TH CA900. "R4ANDO, F,\ 1 6-27-19 NCDEQ COMMENTS NO DATE REMARKS REVISIONS KINDERCARE LEARNING CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 PROJECT NO; 201 7.0643 DATE; 2/12/18 C13 UNDERGROUND CHAMBER DETAIL CHECKED; DM DRAWN; JFH