Loading...
HomeMy WebLinkAboutWQ0037501_Site Plans/Maps_20190628Cz co 1P Ip s N W N a 0 U 0 0 v m rn CO CO 0 0 N W O U 0 J 0 U c 2 U C U N E O 2 !r U) t� m 0 0 LO W M 0 N T a 1 � 1 LOT 16 CAROLINA CROSSINGS SUBDIVISION CHANGE OF TREATMENT TO E=Z TREAT SYSTEM CHATHAM COUNTY, NC - PROJECT No. A35904-00 {Chapel Hill ep, ` J I 5 �� 'YEA . rt I t I -- - - - —-- - --3- r �. I Pr -0 � RBCIRLJti. rrlLJ+t7AIJ% - t ILA Li lrl= _lLIJ_Ec 'r ALLEY �L}r •TFI•_ I'iLL Cary tat f� _ Carpenr ellVw`- _ i _ 1 tlePAW la Et m r C73 r Fearrin ton rr�i� 4� SITE I+ GADEL ��Rr.,5 + I + '1 rr -4L r A Li 174 pi 4{ is . r , f Green el NF P0..rJT r I fi0P.Tc.ESTEA1i-Lz GM F IL + �# MIAS - ■ =rY • r + 1C'-w4k,1'. OCNYs 1 _ _ r� J -9 - ��HiIUCcTCI Iff g ::3A L i F P # �9r',GLi'I I C CL�I.�Cfr,1 f y CT- F i7p 9 PROJECT MANAGEMENT COPYRIGHT C 2018 360 CAROLINA CROSSINGS DR. APEX, NC 27523 EXISTING PERMIT #: WQ0037501 SCHEDULE OF DRAWINGS: COVER SHEET C-101 OVERALL SITE MAP WITH 500' SETBACK C-102 OVERALL SITE PLAN C-103 TREATMENT SYSTEM LAYOUT C-104 TREATMENT SYSTEM SCHEMATICS AND CALCULATIONS C-105 NOTES D-101 D-102 D-103 LICENSE No. C-1039 DETAILS - 1 of 3 DETAILS - 2 of 3 DETAILS - 3 of 3 MacCONNELL & Associates, P. C. 1101 NOWELL ROAD, SUITE 118 RALEIGH, NORTH CAROLINA 27607 P. O. BOX 129 MORRISVILLE, NORTH CAROLINA 27560 TEL: (919) 467-1239 FAX: (919) 319-6510 CIL t t� . C w Q7�tiiuti tf` fld 43 Y ri WENDY C m Kati I I J S\N Mafth ffs Chapel lR fi SITE 7 G � % OLEO THGMP5DN CREEK wq -Rd LOCATION MAP THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING JUNE 28, 2019 DECEMBER 12. 2018 m } (n a W H N W 0 z W W F- L, 0 w c9 z a x U I z 0 (n in D In (n c� z cn In 0 w U a z J 0 w Q U U 0 J 9 J O 2 `L U O w 3 `1 z a It W 0 z Ld Ir z D x a it Q m w Q m I 0 0 0 rn In M Q A61902.00 - BARBARA S, HUNTER AND FRANK W. ROCKHOLD - LOT 16 CAROLINA CROSSINGS SUBDIVISION - CHANGE OF TREATMENT TO E-Z TREAT SYSTEM / I / / NOTES 1. SEE C-105 FOR ALL GENERAL NOTES.LOT 14 SCOTT & MELANIE SHADOANI LOT 4 PIN: 0714-24-9576 DB: 1520 PG: 734 PB: 94 11 PG: 201 LEGEND\ O - - - - - - - - - ADJACENT BOUNDARY BOUNDARY (PROPERTY) TY) 0000 � CONTOURS INDEX �CONTOURS INTERMEDI ATE 310v I/ DRAIN FIELD (SEPTIC) AREA I0000. E E E ELECTRIC LINE EXISTING FENCE \ \ \ I \ I \ \ \ I I I II I I I DAVIDSON M, & KATHY R. BURNS \\ - _\ I / _ - - - - - - EXISTING STREAM \ \ \ \ , I \ _ \ / / I I \ I I PIN: 0714-34-0139 - - _ - - J DB: 646 PG. 131 100' STREAM BUFFER \ \\ \ \ \I \ \\ PB: 94 PG: 24 \LOT 3 _ - - - I \ � SETBACKS 280 100 WELD0 \ / RETURN LINES --- SETIBACKI� I / � o SUPPLY LINES Cc CO CLEAN OUT CID CONTROL PANEL EEXISTIN POND \ \ // / / / �, / / EZRT E-Z TREAT RECIRC. TANK EXISTING �� I I / E-Z E-Z TREAT TREATMENT UNIT DWELLS NG i / / I I FDT FIELD DOSING TANK 270 "DWELLING / \ \ LOT 15 V A \ � / / / I ST SEPTIC TANK o I I \\ \\\\\� ����/// I I 1 HU HYDRAULIC UNIT o II I - - _ I I UV ULTRAVIOLET DISINFECTION \-- -----� �� / _ I \ M METER o I I I II ( II II-- // I I II I \ 1 \\ `�\-_--_-----/ \ I \ \\ I ZV ZONE VALVE - V �\ V A I IPF IRON PIPE FOUND EXISTING v --- / \ DWELLING \\ -----// �^\ \\ \ \ \ \\ � � POWER POLE \ \ \ \ �\ \ / \ \ �_ EXISTING WELL THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN \ V A \ \ _ _ PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS S7g• \ A V A — — _ _ _ _ — _ — \ I NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD 09 03" \ \ \ \ — _ \ \ I \ \ \ \ DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY 3a5.20a E \ \ — — — \ I \ \ \ \ \ HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE / 00�` ` 57 ' `v \ \ - _ • AF'F'LYING I I FUK ANY F'UKF'USt. v v N v v — ---- —� I v v v v vv v RECORD DRAWING ��� v ---- _� I 1 I \ 1 � \ —�`� , r� �� I I 77 LOT 21 ov ------ ------ vv v JUNE 28 2019 I I PROPOSE \ \ — - - - I I I GRAPHIC SCALE: 1 " = 60' DWELLIN\G, I 1 \ 0 30 60 120 180 DRAIN FIELD 26.00' BYvQTHERSo \ - - / - ---- ---- REVISIONS I NO. DATE DESCRIPTION 1 06/28/19 RECORD DRAWINGS 100 WELLS o \ TREATMENT v - - - - - - � SE BACK V A. A'SYSTEM JOHN T. & DANA E. BUCKLEY 0 ---PIN: /0714-23/-97/9�6 -o DB: 645 PG: 666 / / / - - - 6 LO PB: 94 PG: 246iV6g. LOT 16 PROJECT MANAGER: PROJECT ENGINEER: -- \o GSM JPH � / DRAWN BY: CHECKED BY: LHB GSM 2>0 DATE: STREAM \ \ \ \ \ \ I / ( / \ / I - / DECEMBER 12, 2018 ,• ,. r cA / /// �� % \ \ \- / �// //1y069 / / \ \ SLOT 17�\ \\ \\\\\\\ \\ 100 STREAM I \ \ \ \ \ \ \ \ \.5 MAGO` ZD/� BUFFER \ \� \ \ \ \ \ \ \ _ / / „p f MacCONNELL 9..�ssV & Associates P. C. 1101 NOWELL ROAD, SUITE 118 , RALEIGH NORTH CAROLINA 27607 - P.O. BOX 129 LICENSE MORRISVILLE, NORTH CAROLINA 27560 SAMUEL & LYNDSEY NEWMAN - - - - - / No. C-1039 TEL: (919) 467-1239 FAX: (919) 319-6510 LOT 18 / � �� I I I I I I / / � \ % �\ \\ \V \ \V A \ V v 'PIN: 0714-33-0464 / DB: 1683 PG: 579 / / / / / I 1 HUNTER I ♦ \ \ \ /� _ BARBARA S. — \\ \ ` \ `\`\ \ `\� Cc., `\ `\\ \ \ \ \ \ _ _ _ — AND FRANK W. ROCKHOLD �\ \ \ 1 \ i\ , \ -� \ \ \ \ ���_ — LOT 16 CAROLINA CROSSINGS SUBDIVISION // \\ \\ \ \\� y , \ / / , //_, �\ \\\\ \\\ tisa s,� I \ \ �\ CHANGE OF TREATMENT 09 97 TO E-Z TREAT SYSTEM CHATHAM COUNTY, NC // de V / I I I I / / , / OVERALL SITE MAP � \ \ I I I // / / ��'� � �� `\ // /' // / ' / // / WITH 500' SETBACK 55'0�\TREAT ENT\SETBAC \ `\ \ \ \ // / / PROJECT NUMBER DRAWING NUMBER \ \ \ \ \ \ \ O \ \ / I / \ \ / � ' '\\\\�\ \\ `\ \\ \\ `\ / � \ \ � A35904.00 C-101 CID 0 N 0 U m w N N N I w 0 z z w 0 w 0 z Q U I z 0 N 0 CD D (N (N 0 z (N (N 0 U Q z J 0 CE U 0 J I 0 J 0 x Y U O w Y z w 0 z Q CE w F- z N CE m CE m I 0 0 0 M Q 435904.00 - BARBARA S, HUNTER AND FRANK W. ROCKHOLD - LOT 16 CAROLINA CROSSINGS SUBDIVISION - CHANGE OF TREATMENT TO E-Z TREAT SYSTEM Cz C0 In 00 W O N 06 N \ `\ EXISTING POND \ / < NOTES \\ \ \ \ I \ \ I \ I \\ \\ EXISTING 1 • SEE C-105 FOR ALL GENERAL NOTES. \ V A I \ \ BUILDING LEGEND - - - - - - - - - ADJACENT BOUNDARY BOUNDARY (PROPERTY) II II \\ \\\\\\ \�\---- I i II II ( o CONTOURS - INDEX CONTOURS - INTERMEDIATE I DRAIN FIELD (SEPTIC) AREA I \ E E ELECTRIC LINE II II I II \\ o EXISTING FENCE EXISTING STREAM \\ I \ 1 \ \\ - --_---- - - - --- 100' STREAM BUFFER \ SETBACKS \ \ \ \ \ \ \ \\ \ \ \ \ \ RETURN LINES \ \ \ \ \ \ \ \ SUPPLY LINES CO CLEAN OUT CID CONTROL PANEL EZRT E-Z TREAT RECIRC. TANK E-Z E-Z TREAT TREATMENT UNIT FDT FIELD DOSING TANK \ �\------- ST SEPTIC TANK ` HU HYDRAULIC UNIT rrNuf7ryL. U \ \ \ \ \ \ - UV ULTRAVIOLET DISINFECTION -- -1 / / V I I I \ ` V A \ V A V --- - -- , -- -- M METER _ - - ZV ZONE VALVE - ° \VA� \\ ` vv------- ---- IPF IRON PIPE FOUND PROPOSED ` COT \ \ \ \ \ \ \ V v --- --- -- --- --- POWER POLE DWELLING v V� \ -Z \ \ �------------------------ QW EXISTING WELL A v DRAIN FIELD V A. \ THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED \ \ v v v A o �� I \ o EZRT UNDER EXISTING V A v � — — — — — — — — — — — — — — — _ _ — — — _ _ UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS \ v v v V 10� �� \ o �PERMfT#: WQ0037501 A — — _ _ — _ -� INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN \ CPS \ \ — — — — — — — — — PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS \ ' PLANS BY: JOHN R. HARMAN P.E. \ _ _ — — _ — _ — — — NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD �= �S TB � FDT ` \ A — — — — — — DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY ACK �V — — — — — — — — _ — HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE HU` _ _ — — — — RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN ZV \\ _ — — — — — — — — / INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE — — / APPLYING IT FOR ANY PURPOSE. RECORD DRAWING \ \ \ \ GRAPHIC SCALE: 1" = 40' V A V A V A 0, o _ — — — / 0 20 40 80 120 260 ��04 �33 \ \ \ \ \ V �� N69. 688 \ \ \ b / / / / / REVISIONS A V A \ .. 18• 00 NO. DATE DESCRIPTION -- -R.- � � � � / / / / / I 1 06 28 19 RECORD DRAWINGS SEE PLANS BY: JOHN R. HARMAN P.E.P E � / � / / / / � � \ �A v v v \ \ v v FOR LAYOPT OF SUPPLY AND ��� v v A `\ v v RETURN LINES MANIFOLDS. \ -- - - \ PROJECT MANAGER: PROJECT ENGINEER: GSM JPH STREAM \\ \\ �\ \\ I I / / / / II 11 I II / DRAWN BY: CHECKED BY: LHB GSM DATE: DECEMBER 12, 2018 0� r / 100' STREAM\BUFFER \ MacCONNELL -7 / - \ 1 \ & Associates P. C. 1101 NOWELL ROAD, SUITE 118 _ - - - - RALEIGH, NORTH CAROLINA 27607 0 ---- I / / I \ �9' s / \ \ \ \ \ \ \ \ \ 28 I l � \ \ \ \ \ LICENSE P.O. BOX 129 MORRISVILLE, NORTH CAROLINA 27560 2 / ^ \ \ \ \ \ \ \ \ \ \ \ \\ \ \ \ \\ \ \ \ \ No. C-1039 TEL: (919) 467-1239 FAX: (919) 319-6510 / I I \� \\ \�\\ BARBARA S. HUNTER --- I ' �'—� I I I ' / / � � \ � \ \ \ \ � AND FRANK W.R KH LD LOT 16 CAROLINA I I _ CROSSINGS SUBDIVISION CHANGE OF TREATMENT Co. / \ _--, �� \\� \\ ��, TO E—Z TREAT SYSTEM CHATHAM COUNTY, NC 0 OVERALL SITE PLAN / 2° 09 \ \ PROJECT NUMBER DRAWING NUMBER - ---- __ — — ��� A35904.00 C-102 00 0 N 0 0 U m w N NQQ Lil d' H N I w 0 z z w O w 0 z Q U I z 0 N 0 CD D (N (N 0 z (N (N 0 U z z CE O U 0 J I 0 J O 2 Y U O w 3 Y z w L� 0 z Q CE F- z N CE m CE m I O O 0 M Q ,35904.00 - BARBARA S, HUNTER AND FRANK W. ROCKHOLD - LOT 16 CAROLINA CROSSINGS SUBDIVISION - CHANGE OF TREATMENT TO E-Z TREAT SYSTEM 00 E m Cl) 00 0 N Cd N C 3 m O O CD O co co Q 0 N w 0 U 0 J N 0 O U Cz c U U E 0 T t� m 0 0 0 O O co co CD N J N 14 \ \ \ 68 \ \ \ 100' STREAM BUFFER \ \ NOTES / LEGEND — — — — — — — — — ADJACENT BOUNDARY BOUNDARY (PROPERTY) CONTOURS — INDEX CONTOURS — INTERMEDIATE — — — — DRAIN FIELD (SEPTIC) AREA E ELECTRIC LINE EXISTING FENCE — — — — — — — EXISTING STREAM 100' STREAM BUFFER SETBACKS RETURN LINES SUPPLY LINES CO CLEAN OUT CID CONTROL PANEL EZRT E—Z TREAT RECIRC. TANK E—Z E—Z TREAT TREATMENT UNIT FDT FIELD DOSING TANK ST SEPTIC TANK HU HYDRAULIC UNIT UV ULTRAVIOLET DISINFECTION M METER ZV ZONE VALVE IPF IRON PIPE FOUND POWER POLE OW EXISTING WELL THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE DRAIN FIELD APPLYING IT FOR ANY PURPOSE. UNDER EXISTING RECORD DRAWING PERMIT#: WQ0037501 PLANS BY: JOHN R. HARMAN P.E. J U N E 285 2019 GRAPHIC SCALE: 1 " = 5' 0 5 10 15 4)1 1 /2" SCH. 40 'VC SUPPLY BY OTHERS) \ A 1 1 /4" PVC RETURN FROM THE FIELD (BY OTHERS) \ SEE PLANS BY: JOHN R.\HARMAN P.E. FOR LAYOUT OF SUPPLY AND RETURN LINES / MANIFOLDS. REVISIONS N0. DATE DESCRIPTION 1 06/28/19 RECORD DRAWINGS I PROJECT SMMANAGER: PROJECTJPH ENGINEER: I DRAWN BY: CHECKED BY: LHB GSM DATE: DECEMBER 12, 2018 +tills kl lle ,, N d[ I• I I I I IRN MacCONNELL 9 & Associates, P. C. 1101 NOWELL ROAD, SUITE 118 RALEIGH, NORTH CAROLINA 27607 P.O. BOX 129 LICENSE MORRISVILLE, NORTH CAROLINA 27560 No. C-1039 TEL: (919) 467-1239 FAX: (919) 319-6510 BARBARA S. HUNTER AND FRANK W. ROCKHOLD LOT 16 CAROLINA CROSSINGS SUBDIVISION CHANGE OF TREATMENT TO E-Z TREAT SYSTEM CHATHAM COUNTY, NC TREATMENT SYSTEM LAYOUT PROJECT NUMBER I DRAWING NUMBER A35904.00 C-103 O N Q U r O U m w H r Q W U' F- N I w O F- z w m Q w O w CD z a U I z 0 0 m D N N 0 z O U z J O a U 0 I 0 0 Y U O Y z 0 z Q Ld w z z V7 Of Of m O O O M Q A35904.00 — BARBARA S, HUNTER AND FRANK W. ROCKHOLD — LOT 16 CAROLINA CROSSINGS SUBDIVISION — CHANGE OF TREATMENT TO E—Z TREAT SYSTEM 00 E m co �q 00 0 N C6 N 3 U m O CD 0 co co Q 0 N w 0 a) m U 0 J 0 U c 2 vi U !_ 0 T 7 W t� m m 0 0 O co M Q 0 N 4 J N a IN. GRADE ±271.0' — DWELLING — F.F.E. ±272.0' (ASSUMED) 4" SCH 4n1 pvr, r 1±269.0' (DWELLING) E—Z TREAT POD FILTER Fcpl FCpl FCpl 111,000 GALLON 1,250 GALLON E—Z TREAT SEPTIC TANK I RECIRCULATION II TANK 4,500 GALLON FIELD DOSING/STORAGE TANK UV 1-1/4" SCH. 40 PVC RETURN FROM FIELDS HYDRAULIC UNIT — GROUND EL. ±275.0' INV. EL. ±273.1 ' EL. ±272.9' 1,250 GALLON SEPTIC TANK NOTES: 1. TANK LOCATIONS ARE NOT TO SCALE SO AS TO SHOW EACH TREATMENT ITEM. 2. ALL GRAVITY LINES SHALL BE 2% SLOPE MIN. ZONE VALVES E—Z TREAT POD FILTER INV.EL. ±272.7' INV.EL. BYPASS ±272.7' 0 INV.EL. 272.5' 1,000 GALLON E—Z TREAT RECIRCULATION TANK 4" SCH. 40 PVC FORCE MAIN GROUND — — — GRAVITY LINE FLOW DIRECTION 0- 1-1/2" SCH. 40 PVC SUPPLY TO ZONE 1, 2, 3, & 4 1-1/4" SCH. 40 PVC RETURN LINE FROM ZONE 1, 2, 3 & 4 GROUND EL. ±274.0' INV.EL. UV ±272.3' 4,500 GALLON DOSING/STORAGE TANK 4" SCH. 40 PVC TREATMENT SYSTEM SCHEMATIC / PROFILE NTS HYDRAULIC UNIT ZONE VALVES TO ZONES 1, 2, 3 & 4 MAINTENANCE SCHEDULE ITEM FREQUENCY TASK SEPTIC TANK 3 — 6 MONTHS CHECK FOR SOLIDS ACCUMULATION, BLOCKAGES, OR BAFFLE DAMAGE, IN/EXFILTRATION, PUMP SEPTAGE. CLEAN EFFLUENT FILTER. 12 MONTHS PUMP OUT ACCUMULATED SOLIDS IF NECESSARY. RECIRCULATION TANK WEEKLY CHECK PUMPS, CONTROLS, ALARMS, FIELD DOSING TANK ELAPSED TIME METERS. 3-6 MONTHS CHECK FOR SOLIDS ACCUMULATION, IN/EXFILTRATION. 12 MONTHS PUMP OUT ACCUMULATED SOLIDS IF NECESSARY. SUPPLY LINES, FORCE MAINS 6-12 MONTHS CHECK FOR EXPOSED PIPE AND LEAKAGE. DISTRIBUTION FIELDS 2-4 WEEKS MOW VEGETATIVE COVER IF APPLICABLE. CHECK FOR EROSION, OR PONDING OF 3-6 MONTHS EFFLUENT. PUMPS, FILTER SYSTEM, MONTHLY & DISTRIBUTION PIPING QUARTERLY SEMIANNUALLY AN N UALLY CHECK FLOW METER READOUT AND COMPARE TO RECORDED FLOWS, CHECK PUMPS AND FILTER SYSTEM FOR LEAKS. REMOVE FILTER COVERS AND INSPECT FOR ACCUMULATION OF DEBRIS. CHECK DIFFERENTIAL PRESSURE GAUGE BEFORE AND AFTER FLUSHING (D.P. SHOULD RETURN TO ORIGINAL OPERATING D.P.) CHECK PUMPS FOR ABNORMAL VIBRATION, TEST THE ALARM FUNCTIONS. REMOVE AND LUBRICATE O—RINGS ON FILTER CANISTER, REPLACE IF DAMAGED, CLEAN 1-1/2" FILTER SCREEN AT HYDRAULIC UNIT. REMOVE FILTER SCREEN AND REPLACE, CLEAN USED FILTER SCREEN IN MILD ACID SOLUTION AND STORE FOR NEXT ANNUAL REPLACEMENT, FLUSH FIELD SUPPLY AND RETURN MANIFOLDS BY REMOVING (UNSCREWING) AIR/VACUUM BREAKERS. E—Z TREAT TREATMENT MONTHLY INSPECT CONTROL/ALARM PANEL, SYSTEM PUMPING SYSTEM EFFLUENT FILTERS/PUMP SCREENS, PROCESSING TANK, AND E—Z TREAT POD FILTER. (TREATMENT UNIT) AN N UALLY CHECK AND/OR REPLACE BATTERIES IN FLOW METER. (IF APPLICABLE) ULTRAVIOLET DISINFECTION 3-6 MONTHS WIPE (CLEAN) UV LAMPS. UNIT CHECK INTENSITY AND REPLACE LAMP WHEN REQUIRED. NOTES THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING JUNE 28. 2019 REVISIONS N0. DATE DESCRIPTION 1 06/28/19 RECORD DRAWINGS I PROJECT SMMANAGER: PROJECTJPH ENGINEER: I DRAWN BY: CHECKED BY: LHB GSM DATE: DECEMBER 12, 2018 ,5S11l 11 ll! 7!1 . 04 I� O � � SEAL - AA MacCONNELL 9 & Associates, P. C. 1101 NOWELL ROAD, SUITE 118 RALEIGH, NORTH CAROLINA 27607 P.O. BOX 129 LICENSE MORRISVILLE, NORTH CAROLINA 27560 No. C-1039 TEL: (919) 467-1239 FAX: (919) 319-6510 BARBARA S. HUNTER AND FRANK W. ROCKHOLD LOT 16 CAROLINA CROSSINGS SUBDIVISION CHANGE OF TREATMENT TO E-Z TREAT SYSTEM CHATHAM COUNTY, NC TREATMENT SYSTEM SCHEMATICS AND CALCULATIONS PROJECT NUMBER I DRAWING NUMBER A35904.00 C-104 m w U) r w F- N I w 0 F- z w m Q w O w CD z a U I z O 0 m D N (N 0 z O U z J O Q U O I 0 J O Y U O Y z _ 0 z Q Ld w z z V7 Of m Of m O O O M Q A35904.00 - BARBARA S, HUNTER AND FRANK W. ROCKHOLD - LOT 16 CAROLINA CROSSINGS SUBDIVISION - CHANGE OF TREATMENT TO E-Z TREAT SYSTEM 00 E m Cl) 00 0 N C6 N 3 U m 0 0 CD O co co g 0 N w 0 U 0 J 0 U c O U U !_ 0 2 _T 7 W t� m ED 0 0 O O Ln co M Q W O N 4 J N a GENERAL NOTES SITE RESTORATION 1. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL TRADES AND SUBCONTRACTORS. CONTRACTOR IS ALSO RESPONSIBLE FOR FIELD VERIFYING DIMENSIONS, ELEVATIONS, AND LOCATIONS OF 1. BACKFILL WITH SUITABLE LOOSE MATERIAL (SANDY LOAM TO SANDY CLAY LOAM) FREE OF LARGE OR ALL EXISTING CONDITIONS AND UTILITIES. DAMAGING OBJECTS, SEED AND STRAW BACKFILLED AREAS (OR SOD WHEN REQUIRED). 2. CONTRACTOR IS RESPONSIBLE FOR INSTALLING SYSTEM IN ACCORDANCE WITH ALL STATE & LOCAL REGULATIONS & POLICIES. 2. PROVIDE EROSION PROTECTION FOR BACKFILL MATERIAL IN ACCORDANCE WITH STATE AND COUNTY 3. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE SOIL EROSION AND SEDIMENTATION CONTROL REQUIREMENTS. STANDARDS AND MAINTAIN UNTIL PERMANENT PROTECTION IS ESTABLISHED. 4. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE OSHA, NCDOT AND LOCAL SAFETY REQUIREMENTS. 3. BACKFILL SHOULD BE GRADED TO PREVENT THE INFILTRATION OF SURFACE WATER AND DIVERT STORM 5. CONTRACTOR IS RESPONSIBLE FOR REPAIRING ALL CONSTRUCTION DAMAGE EXPEDITIOUSLY AND AT NO ADDITIONAL COST TO THE OWNER. WATER RUN-OFF AWAY FROM THE SYSTEM. WHEN ADDITIONAL FILL IS REQUIRED, IT SHOULD BE PLACED 6. DRAIN ALL ROOF AND TOE DRAINS AWAY FROM DRIP FIELD AND TREATMENT UNITS. AFTER SYSTEM IS INSTALLED FROM THE EDGES CROWNED IN THE MIDDLE AND FEATHERED OUT 10' 7. PROVIDE MINIMUM 100 FEET OF SEPARATION FROM ANY WELL TO WASTEWATER TREATMENT UNITS AND DISPOSAL SYSTEMS IF APPLICABLE. BEYOND THE DISPERSAL AREA. FILL SHOULD BE TEXTURE GROUP II OR III AND FREE OF LARGE STONES 8. WASTEWATER AND IRRIGATION SYSTEMS SHALL COMPLY WITH IWWS-2015-3-R2 AND ORGANIC DEBRIS. TOP 2" SHOULD BE SUITABLE FOR ESTABLISHMENT OF LAWN. 9. ALL PIPE SHALL BE SCHEDULE 40 PVC UNLESS OTHERWISE NOTED. 10. VORTEX FILTER IN HYDRAULIC UNIT SHALL BE INSPECTED UPON EACH REGULARLY SCHEDULED MAINTENANCE VISIT. 11. INSTALLER IS RESPONSIBLE FOR ENSURING DISPERSAL AREA WAS PROPERLY CLEARED & SOIL MOISTURE CONDITIONS ARE CONDUCIVE FOR INSTALLATION PRIOR TO BEGINNING INSTALLATION. 12. EJECTOR PUMP MAY BE REQUIRED FOR BASEMENT FIXTURES. INSTALLER IS RESPONSIBLE FOR VERIFICATION. 13. KEEP ALL EXCAVATIONS 20' FROM INSTALLATION AND RESERVE AREA. TREATMENT UNITS 14. KEEP WELL AND SEPTIC SYSTEM OUT OF ANY UTILITY EASEMENTS AND AT LEAST 10' FROM UTILITY LINES. 15. DO NOT INSTALL LAWN IRRIGATION SYSTEMS WITHIN 20 FEET OF DISPERSAL AREA. 1. SAMPLING CHAMBER OR MEANS OF COLLECTING A FRESH SAMPLE SHALL BE PROVIDED FOR ALL TS-1 & 16. DO NOT CONNECT WATER TREATMENT SYSTEMS, CONDENSATIONS DRAINS OR SUMP PUMPS TO ONSITE SYSTEM. TS-2 SYSTEMS. IT IS PREFERRED THAT THE INLET OF THE PUMP CHAMBER BE USED AS THE SAMPLING 17. IF A PRE-CONSTRCTION MEETING REQUIRED BY PERMIT, PLEASE CALL TO SCHEDULE. LOCATION WHEN A PUMP IS REQUIRED. 18. ANY DEVIATION FROM THIS DESIGN MUST BE APPROVED BY THE LOCAL HEALTH DEPARTMENT AND THE ENGINEER PRIOR TO INSTALLATION. 2. SYSTEM INSTALLATION MUST COMPLY WITH ALL LOCAL ORDINANCES AND POLICIES. 19. ELECTRICAL WIRING SHOULD BE INSTALLED BY A LICENSED ELECTRICAL CONTRACTOR, ACCORDING TO NEC, STATE AND LOCAL ELECTRICAL CODES, AS APPLICABLE. 20. CONTRACTOR IS TO INSTALL TANKS ON UNIFORMLY FIRM AND STABLE COMPACTED GROUND, CRUSHED STONE IS RECOMMENDED TO PROVIDE UNIFORM SUPPORT TO TANK BOTTOM ESPECIALLY IN POOR, WET OR ROCKY SOILS. 21. ALL TANKS MUST BE WATER -TIGHT AND CONFORM TO APPLICABLE LOCAL AND STATE REGULATIONS AND POLICIES. 22. ALL PVC JOINTS SHALL BE PRIMED AND CHEMICALLY FUSED UNLESS THREADED. 23. MAXIMUM COVER OVER TANKS AND DISTRIBUTION BOXES VARIES BY MANUFACTURER AND COUNTY. THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED 24. DISPERSAL FIELD CORNERS OR PROPERTY CORNERS SHOULD BE MARKED BY A LICENSED SURVEYOR PRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR VERIFYING LOCATIONS MATCH UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS THE CONSTRUCTION DRAWING. INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS 25. REFER TO SITE DRAWING FOR ANY SPECIAL REQUIREMENTS. NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD 26. MACHINERY SHOULD AVOID PERCOLATION AREA. DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE 27. MACHINERY SHOULD NOT TRAVERSE EXCAVATED/EXPOSED PERCOLATION AREA. RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE 28. ALL SUPPLY AND RETURN LINES NOT DESIGNED TO DRAIN BACK SHOULD BE PROTECTED FROM FREEZING. APPLYING IT FOR ANY PURPOSE. RECORD DRAWING DUNE 28. 2019 ELECTRICAL NOTES 1. THREE DIFFERENT CONTROL PANELS WILL CONTROL THE WASTEWATER SYSTEM. ONE CONTROLS THE PRETREATMENT, ONE CONTROLS THE FINAL DISPERSAL, AND ONE CONTROLS THE ULTRAVIOLET DISINFECTION. 2. EACH PANEL SHALL BE APPROXIMATELY 13" WIDE X 15" HIGH AND IS A NEMA 4X, UL RATED ENCLOSURE. THE PANELS SHALL BE SUPPLIED BY THE SYSTEM DISTRIBUTOR. 3. THE PANELS SHALL BE MOUNTED BY THE ELECTRICIAN WITHIN 10' OF THE TANK UNITS. THEY SHALL BE MOUNTED NEXT TO EACH OTHER AND 48" - 60" OFF THE FINISHED GRADE TO THE BOTTOM OF THE ENCLOSURE. 4. THE INSTALLER'S ELECTRICIAN SHALL MAKE THE INTERNAL PANEL CONNECTIONS OF THE PUMP/UV AND CONTROL CORDS. EACH CONTROL PANEL SHALL CONTAIN A WIRING SCHEMATIC IDENTIFYING ALL TERMINAL CONNECTIONS. THE SYSTEM INSTALLER SHALL BUNDLE AND MARK EACH CORD WITH THE APPROPRIATE IDENTIFICATION AND SECURE IN THE ACCESS RISER AT THE DIFFERENT PUMP/UV POINTS. 5. THE PRETREATMENT CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 20 AMPS, 115 VOLTS, SINGLE PHASE SUPPLIED FOR THE PUMP. 6. THE PRETREATMENT CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 15 AMPS, 115 VOLTS SUPPLIED FOR THE ALARM / CONTROL SIDE OF THE PANEL. 7. THE FINAL DISPERSAL CONTROL (DRIP) PANEL REQUIRES A DEDICATED CIRCUIT OF 20 AMPS, 115 VOLTS, SINGLE PHASE SUPPLIED FOR THE PUMPS. 8. THE FINAL DISPERSAL CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 15 AMPS, 115 VOLTS SUPPLIED FOR THE ALARM / CONTROL SIDE OF THE PANEL. 9. THE ULTRAVIOLET DISINFECTION UNIT REQUIRES A DEDICATED CIRCUIT OF 20 AMPS, 115 VOLTS. 10. A MINIMUM CONDUIT SIZE OF 1 1/" SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICIAN AS A CONNECTION BETWEEN EACH CONTROL PANEL AND THEIR RESPECTIVE TERMINATION POINTS OUT IN THE TANK AREA. 11. ALL OPEN CONDUIT ENDS SHALL HAVE REMOVABLE CLAY TYPE DUCT SEAL EMBEDDED TO PREVENT GASSES AND MOISTURE FROM ENTERING THE CONTROL PANELS. DO NOT USE PERMANENT SILICONE OR EXPANDABLE FOAM PRODUCTS. 12. ALL PUMP AND FLOAT CONTROL CORDS SHALL BE SUPPLIED WITH EITHER 30' OR 50' LEADS. THIS WILL HELP KEEP SPLICES TO A MINIMUM AND SHOULD BE AVOIDED IF AT ALL POSSIBLE. IF A SPLICE MUST BE USED, IT MUST BE MADE ABOVE GRADE IN A PLASTIC NEMA 4X JUNCTION BOX. 13. ALARMS SHALL BE AUDIBLE AND VISUAL. 14. AUDIBLE/VISIBLE ALARMS SHALL BE EXTERNAL TO ANY STRUCTURE. OPERATING REGIME FOR DRIP IRRIGATION SYSTEM 1. SYSTEM IS DESIGNED AND CONTROLS (MICROPROCESSORS) ARE PROVIDED TO DOSE THE E-Z TREAT TREATMENT UNITS. SEE SHEET C-106 FOR "ON" AND "OFF" TIME SETTINGS. PUMPED DRIP IRRIGATION FLOW SHALL PASS THROUGH A FLOW METER. WHEN THE PREPROGRAMMED VOLUME IS REACHED THE ACTIVE PUMP WILL BE DE -ENERGIZED. THE PUMP WILL ALSO DE -ENERGIZE IF THE LOW WATER LEVEL "PUMP OFF" SWITCH IS ACTIVATED. SEE SHEET C-106 FOR FIELD DOSING INFORMATION. 2. IF THE HIGH WATER LEVEL "ALARM" FLOAT SWITCH IS ACTIVATED, THE SYSTEM WILL BEGIN ITS OPERATION OF DELIVERING THE PREDETERMINED DOSE VOLUME, AND SHALL ALSO ENERGIZE THE AUDIBLE AND FLASHING ALARM FIXTURES (ONCE ENERGIZED, THE FLASHING AND AUDIBLE ALARM UNITS WILL ONLY BE RESET MANUALLY OR BY REACHING LOW LEVEL CONDITIONS). 3. THE MICROPROCESSOR WILL ALSO CONTROL THE PERIODIC BACK WASHING OF THE VORTEX FILTER AND THE FLUSHING OPERATION OF THE SUB -FIELD LATERAL NETWORK. FILTER BACK WASHING SHALL OCCUR AT THE END OF EACH DOSE CYCLE. SYSTEM LATERAL FLUSHING SHALL OCCUR WHEN THE MICROPROCESSOR SENSES RECOGNITION OF A PRESET ELAPSED TIME SINCE LAST SYSTEM FLUSH (USUALLY 28 DAYS). THE SYSTEM SHALL BE CONFIGURED TO ALLOW FOR MANUAL INITIATION OF BACK WASHING FILTERS OR SUB -FIELD SYSTEM FLUSHING. 4. THE CONTROL PANEL SHALL INCLUDE, BUT NOT BE LIMITED TO, AN "AUTO/MANUAL" SYSTEM CONTROL SWITCH, STOP/START SWITCH FOR EACH PUMP, NON-RESETTABLE ELAPSED TIME RECORDER FOR EACH PUMP, AND INDIVIDUAL PUMP RUN LIGHTS. 5. THE CONTROL PANEL SHALL BE A NEMA 4X ENCLOSURE. ALL SUPPORTING CONTROL UNITS, IF NOT HOUSED WITHIN THE CONTROL PANEL, SHALL BE IN A SEPARATE NEMA 4X ENCLOSURE. REVISIONS N0. DATE DESCRIPTION 1 06/28/19 RECORD DRAWINGS I PROJECT SMMANAGER: PROJECTJPH ENGINEER: I DRAWN BY: CHECKED BY: LHB GSM DATE: DECEMBER 12, 2018 P SEAL- �7D�° .'- - r ;`5' •.LNG I���� ��. MacCONNELL & Associates, P. C. 1101 NOWELL ROAD, SUITE 118 -- RALEIGH, NORTH CAROLINA 27607 P.O. BOX 129 LICENSE MORRISVILLE, NORTH CAROLINA 27560 No. C-1039 TEL: (919) 467-1239 FAX: (919) 319-6510 BARBARA S. HUNTER AND FRANK W. ROCKHOLD LOT 16 CAROLINA CROSSINGS SUBDIVISION CHANGE OF TREATMENT TO E-Z TREAT SYSTEM CHATHAM COUNTY, NC NOTES PROJECT NUMBER I DRAWING NUMBER A35904.00 C-105 O N Q H 2 U O U m w H r Q W U' F- N I w O F- z w m Q w O w CD z Q U I z O 0 m D N N 0 z O U Z J O Q U O I 0 J O Y U O Y Z Q _ 0 Z Q Ld w z z V7 Of m Of m m O O O M Q A35904.00 - BARBARA S, HUNTER AND FRANK W. ROCKHOLD - LOT 16 CAROLINA CROSSINGS SUBDIVISION - CHANGE OF TREATMENT TO E-Z TREAT SYSTEM 00 L \\\\\\ \/ \\ /cz 0 J LO 0 0 ca .) �1 In a) E 0 L 10C n 0 n 12' y� MIN. (TYP.) UIRE., oURIGU ULIRHVIULEI UIJIIVFEUIIUIV UIVII (SEE 2/D-103 FOR DETAILS) NTS 0" V r," DOADn WITU Al I IAAIAII ILA 30" 0 E-Z SET 24" 0 E-Z SET RISER RISER W/COVE W/COVER (TYP. UNLESS PRECAST CONCRETE OTHERWISE NOTED) "DONUT" (OPTIONAL) NOTE: FIELD VERIFY PRIOR (TYP.) TO ORDERING RISERS _ 3/4" SCH. 40 FLEX 3/4„ Q inE2 PVC RECIRC. LINE X PVC PVC \\ \\ \\\\\\\\\\\ \\\\\\\\ \/ IX w OAT TREE ---------- 2" VENT—\40 PVC ��A/VA \ VA/VA//%\�/%\�/%\�/%\� °° EFFLUENT BYPASS HIGH WATER ALARM=8" FROM TOP WATER LINE VALVE BY E-Z TREAT 4" SCH. 40 PVC N DROP TEE (TYP.) DOSE ENABLE=21" ABOVE FLOOR to SIMTECH STF-110 EFFLUENT L - N FILTER, OR ENGINEERS n APPROVED EQUAL SEE RECIRCULATION PUMP OFF=18" ABOVE FLOOR 3 TANK SECTION MERCURY FLOAT o DETAIL THIS SHEET SWITCHES (2) N N 3" N 00 3» 1-1/2" SCH. 40 PVC FLOAT TREE JZ I 1/3 TANK LENGTH I ALL TANKS REQUIRE A STA-RITE HIGH HEAD `O STONE MULTI -STAGE SUBMERSIBLE 6" THICK 57 # EFFLUENT PUMP CATALOG BEDDING (TYP.) NUMBER STEP 30 1 HP A A 11111f- ■ A 11111f- ■ ■ / A A ■ A A ■ ■ ■ 11111f- ■ A ■ 11111f� ■ ■ / ■ ■� ■ ■ ■� ■� w w ■ f• ■ w ° w 11111f- k w M A 11111f- W ■ ■ / w � w 11111f- ■ w & ■ w I I 30"0 E-Z SET RISER W/COVER TURBINE I 2 PUMP \ DAVID BRANTLEY & SONS \� TRAFFIC -RATED 00 + 4,500 GALLONS FIELD DOSING/STORAGE TANK PT-H2O-506 OR APPROVED EQUAL � i I TO HYDRAULIC UNIT I FLOAT TREE (TYP.) I I I I I 167" ALARM LIGHT CONTROL PANEL (LOCATED WITHIN 10-FEET OF TANKS) H DIRECT BURY CABLE TO PANEL \ \ \ \ \ \ \ \ \ \ \ \ \ AA�VAAiVAAiVAAiVAAiVAA/AAjAAjAAx \\\\\ -1-1 /2" PVC x\ \ // � CHECK VALVE j/AA//%V�%V�%V�/��\///\//AA/A� UNION p P \/ SCH. 40\\j\\ a ______ /PVC FULL UNION 1-1/2" SCH. 40 PVC LINE TO FILTER POD CAST -A -SEAL 402 RUBBER —3/16'ANTI-SIPHON BOOT (TYP.) o HOLE (TYP.) 0)6" 3" PVC STAND 1-1/2" SCH. 40 PVC FULL UNION d FLOAT TREE BRACKET 3/1 6"ANTI -SIPHON I� HOLE (TYP.) SECONDARY TIMER HIGH WATER ALARM L DOSE ENABLE PUMP OFF MERCURY FLOAT SWITCHES (4) 0 / n 1-1/2" SCH. 40J PVC FLOAT TREE STA-RITE HIGH HEAD MULTI -STAGE SUBMERSIBLE EFFLUENT PUMP CATALOG NUMBER STEP 30-15221 (1 HP) NOTES 1. SEE C-105 FOR GENERAL NOTES. 2. CAST INLET AND OUTLET BOOTS ARE REQUIRED FOR ALL TANKS. 3. ALL RISER LIDS SHALL HAVE SS TAMPER RESISTANT BOLTS. 4. ALL PIPING SHALL BE SCH 40 PVC UNLESS OTHERWISE NOTED ON PLANS. ALL PVC PIPES SHALL BE BURIED A MINIMUM OF 3 FEET UNLESS SHOWN OTHERWISE. 5. SEPTIC TANKS SHALL BE CONSTRUCTED WITH A BAFFLE WALL DIVIDING THE TANK INTERIOR 2/3rd TO 1/3 rd. THE BAFFLE WALL SHALL BE CONSTRUCTED TO PERMIT PASSAGE OF EFFLUENT THROUGH A SLOT OR HOLES LOCATED BETWEEN 45 AND 55 PERCENT OF THE INTERIOR DEPTH. 6. ALL TANKS SHALL HAVE A MINIMUM 28-DAY CONCRETE STRENGTH OF 4,500 PSI. 7. TANKS SHALL MEET REINFORCING REQUIREMENTS TO ACCOMMODATE 300 POUNDS PER SQUARE FOOT. EITHER STEEL REINFORCING WIRE, REBAR OR APPROVED FIBER MAY BE USED. 8. ALL JOINTS (MID -SEAM, TOP -SEAM) SHALL BE SEALED USING CONCRETE SEALANTS BUTYL SEALANT # CS-102 MEETING ASTM C-990. 9. TANKS SHALL BE LEAK -TESTED PRIOR TO SYSTEM START UP BY APPLYING A VACUUM OF 5-INCHES OF MERCURY WITH RISER ASSEMBLIES IN PLACE OR A 24-HOUR STATIC WATER TEST, IN ACCORDANCE WITH ASTM STANDARDS. 10. ALL PIPE PENETRATIONS THROUGH PRECAST CONCRETE TANKS SHALL BE PRESS -SEAL CAST -A -SEAL 402 RUBBER BOOTS AND GROUTED. 11. CONTRACTOR MAY USE LARGER TANKS. 12. MAXIMUM COVER OVER NON H-20 TANKS SHALL BE 30". 13. ALL SERVICE ACCESS OPENINGS WILL BE A MINIMUM OF 24 INCHES. EXCEPTIONS MAY BE MADE ON A CASE BY CASE BASIS WITH E-Z TREAT'S PRIOR WRITTEN APPROVAL. ALL ACCESS OPENINGS SHALL BE FITTED WITH E-Z SET RISER ASSEMBLIES. SERVICE ACCESS OPENINGS FOR THE RECIRCULATION CYLINDER SHALL BE A 30-INCH OPENING AND FITTED WITH AN E-Z SET 30-INCH RISER ASSEMBLY. TRAFFIC RATED TANKS SHALL HAVE CONCRETE RISERS. 14. NON -CONCRETE TANKS SHALL NOT BE USED IN CONJUNCTION WITH THE E-Z TREAT SYSTEM WITHOUT PRIOR WRITTEN APPROVAL BY E-Z TREAT. 15. THE FILTER POD INVERT OUT SHALL BE A MINIMUM OF 6" ABOVE THE INVERT IN OF THE RECIRCULATION TANK OR 1/4-INCH PER FOOT SLOPE, WHICHEVER IS GREATER THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING JUNE 289 2019 REVISIONS NO. DATE I DESCRIPTION I PROJECT S�MANAGER: PROJECTJPH ENGINEER: I DRAWN BY: LH B CHECKED BY: GSM DATE: DECEMBER 12, 2018 -O�_. —1-1/2" PVC CHECK VALVE 17069 DIRECT BURY CABLE TO °°,,5. MN&C PANEL ,��l ZalGf MacCONNELL & Assoc ates, P C. . 1101 NOWELL ROAD, SUITE 118 RALEIGH NORTH CAROLINA 27607 P.O. BOX 129 LICENSE MORRISVILLE, NORTH CAROLINA 27560 NO. C-1039 TEL: (919) 467-1239 FAX: (919) 319-6510 1-1/2" SCH. BARBARA S. HUNTER 40 PVC TO HYDRAULIC UNIT AND FRANK W. ROCKHOLD LOT 16 CAROLINA CROSSINGS SUBDIVISION CHANGE OF TREATMENT TO E-Z TREAT SYSTEM 6" CHATHAM COUNTY, NC ° 4 e 3" PVC STAND DETAILS - 1 of 3 D-101 NTS PROJECT NUMBER DRAWING NUMBER A35904.00 D-101 J 55904.00 - BARBARA S, HUNTER AND FRANK W. ROCKHOLD - LOT 16 CAROLINA CROSSINGS SUBDIVISION - CHANGE OF TREATMENT TO E-Z TREAT SYSTEM 00 3/4" SCH. 40 PVC RECIRC LINE FIN. GRADE 4 ° ° 1-1 /2"x 1-1 /2"x3/4" TEE BRANCH 30" 0 E—Z SET __\ zRISER W/COVER SEE GEN. NOTES 1-1/2" PVC N Q CHECK VALVE 1-1/2" ELBOW (TYP.) 1-1/2" SCH. 40 PVC FULL UNION (TYP.) °ae 3/4" BALL VALVE UNION FROM PUMP 1-1/2" SCH. 40 PVC LINE TO FILTER POD 'A DENITRIFICATION SECTION D-102 NTS DDC/lACT CONCRETE (OPTIONAL) 4" 0 RECIRCULATION TANK SECTION NTS FINISHED GRADE 1-1/2"x1" PVC S X MIP ADAPTER (TYP. OF 2)� 1 D-102 NOTE: 1. PIPING TO BE 4" SCH. 40 PVC. 2 GRAVITY CLEANOUT 3 D-102 NTS D-102 " 90' BEND " TO LTRAVI OLEf ISINFECTION NIT v) H LL TANKS EQUIRE A 6" HICK STONE 12" ASE (TYP.) 1 MIN. 1" POSITIVE DISPLACEMENT NOTES: WATER METER 1. BADGER MODEL 55 FLOWMETER FOR IRRIGATION LINE. 6" MIN. #57 HEAT PAD RECTANGULAR HDPE STONE (TYP.) METER BOX IRRIGATION FLOW METER NTS MINI —CLICK RAIN SENSOR LEAD WIRES TO CONTROLLER NOTE: 1. DO NOT COVER. 2. RAIN SENSOR SHALL BE MODEL MINI—CIK BY HUNTER RAIN SENSOR NTS C D-102 PVC END CAP 4 D-102 E—Z TREAT POD FILTER SYSTEM U- II 1-1/2" 0 SUPPLY LINE Lq II M I I III IIII I I 4" 0 RETURN LINE 4"0 CORRUGATED \-6" THICK #57 STONE SLOTTED DRAIN PIPE BEDDING (TYP.) E—Z TREAT POD SECTION NTS NOTE: 1. SEE SITE PLAN FOR ORIENTATION. FIELD RETURN LINE (SEE SITE PLAN FOR PIPE SIZE) l �0 ALA 6G REDUCER 4" x 2" CLEAN �' REDUCER OUT 4" PVC TO SEPTIC TANK 4" PVC 4" PVC WYE TEE- FIELD RETURN LINE DETAIL NTS F3' ALL AROUND SELECT BACKFILL FREE OF DEBRIS II 4" 0 CORRUGATED SLOTTED DRAIN PIPE CHECKED BY: GSM DATE: DECEMBER 12, 2018 NOTES i��`l���lil�af•`Z�III[�1��P►I�7�III[�iI���I�1<�I�I��L'1��N>f��•� THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING JUNE 285 2019 REVISIONS NO. DATE DESCRIPTION 1 6/28/19 RECORD DRAWINGS IPROJECT JPH TMANAGER: PROJECT ENGINEER: I DRAWN BY: LH B �S�, wl JL Irt MacCONNELL & Associates, P. C. 1101 NOWELL ROAD, SUITE 118 RALEIGH, NORTH CAROLINA 27607 P.O. BOX 129 LICENSE MORRISVILLE, NORTH CAROLINA 27560 NO. C-1039 TEL: (919) 467-1239 FAX: (919) 319-6510 BARBARA S. HUNTER AND FRANK W. ROCKHOLD LOT 16 CAROLINA CROSSINGS SUBDIVISION CHANGE OF TREATMENT TO E-Z TREAT SYSTEM CHATHAM COUNTY, NC DETAILS - 2 of 3 PROJECT NUMBER DRAWING NUMBER A35904.00 D-102 w H !n r H Q W W' H N w O H H z W a w w O W c� z a U I z 0 U) 0 m D In In O z E5 In 0 m U a z O a U 0 O J I 0 J 0 2 Y U 0 0 `L z w 0 z Q m w z z 2 Q Q m Q m O O Ln Q A35904.00 - BARBARA S, HUNTER AND FRANK W. ROCKHOLD - LOT 16 CAROLINA CROSSINGS SUBDIVISION - CHANGE OF TREATMENT TO E-Z TREAT SYSTEM DD D1 Branch Circuit Protection Device/Disconnect Means Field Provided - PUMP size per manufacturing specifications for pump/motor Incoming Power 120/230 VAC, 50/60HZ PUMP LOAD G L1 L2/N 120/230 VAC, 0-16 AMPS, 50/60 HZ L3 T3 PUMPS MUST CONTAIN INTEGRAL THERMAL OVERLOAD PROTECTION! GL O � L2 Tj 2 T2 ®� PUMP1 L1 T1 CB1 20A M1 GROUND TO GROUND LUG CONTROL Incoming Power 120 VAC, 50/60HZ L1 N 1 1 CB2 110A CR1 TD1 FS2 - Timer Enable 113 14 14 1 1 I 3 TB TB4 ® I FS3 - High Alarm TB5 TB6 Al ® ® CR FS1 - Low Alarm TB1 T132 Al R1 A2 Swi vvA °OFF AUTO A2 ALARM BEACON 21 CR1 22 11 12 11 CR2 14 SW2 CR3 14 Al Test Silence F1, F2 FUSE MUST BE DREPLACED WITH 1 AMP 5mmX20mm TYPE FAST ACTING 250 V MAX. This control panel is for timed dosing applications. When the timer enable float is up, the timer will start timing for the duration of the "Off' time and when complete, the pump will start for the duration of the "On" time. Both Off and On times are adjustable. This pattern repeats until the timer enable float lowers and turns off. The Low float acts as a redundant off and will also activate the alarm. If the level reaches the High float switch, the alarm will activate. TB1 TB2 TB3 TB4 TB5 TB6 FS3 - High FS1 - Low FS2 - Level Level Timer Enable A2 Float Switch Field Wiring *FS1 - Normally Open, Narrow Angle *FS2 - Normally Open, Wide Angle *FS3 - Normally Open, Narrow Angle -- FIELD WIRING FIELD SUPPLIED TERMINAL BLOCK TB Power Wiring = BLK 120VAC Control wiring = RED Neutral = WHT Ground = GRN TIGHTENING AWG/ OR TORQUE IN INCH CIRCULAR POUNDS MILL SIZE SCREW EXTERNAL DRIVER DRIVE WRENCH 14 35 75 12 35 75 10 35 75 8 40 75 6 45 110 4 45 110 2 50 150 1 50 1 150 110 50 1 180 2/0 50 180 LEGEND CR CONTROL RELAY CB CIRCUIT BREAKER GL GROUND LUG Swl HOA SWITCH SW2 TEST/SILENCE SWITCH R ALARM BEACON B ALARM BUZZER M1 MAGNETIC CONTACTOR G1 PUMP RUN INDICATOR GL GROUND LUG FS FLOAT SWITCH TD3 Repeat Cycle Timer Off Hrs On o 0 6 8 Off R 10 12 Scale Min ® G Off R- On On To set the timer, use a screwdriver to change timer Scale (0-12 most common). Use a screwdriver to change the "On" time increments (minutes most common). Use a screwdriver to change the "off' time increments (hours most common). Turn the dial with the Red line to the desired "On" time (this example is 2 minutes). Turn the dial with the Green line to the desired "Off' time (this example is 4 Hours). Notes: 1. WARNING! Electrical Shock Hazard! Disconnect power before servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes. 2. Install in accordance with National Electric Code, NFPA 70, Seal all boxes, fittings and conduit with appropriate seal devices to prevent moisture and gases from entering enclosure. 3. Connect all grounds to a good ground. 4. Dashed lines represent field wiring - Use minimum 60 deg C Copper Wire 5. Branch Circuit Protection Device/Disconnect Means Field Provided. Terminal Connections CONTROL PUMP PUMP Incoming Power Incoming Power Connection 120 VAC, 50/60HZ 120/230 VAC, 50/60HZ L1 N I I L1 L2/N I I TB1 TB2 TB3 TB4 TB5 TB6 ,�, ,�, TT11 T2 OJ J I �O FS3 - High c G)O FS1 -Low FS2 Level Timer Enable O O Z Z Z Float Switch Field Wiring o *FS1 - Normally Open, Narrow Angle G) O *FS2 - Normally Open, Wide Angle *FS3 - Normally Open, Narrow Angle NOTES: 1. PANEL BY ALDERON, OR EQUAL. 2. PANEL TO BE SUPPLIED BY E—Z TREAT. 230V/115V-10-3 WIRE SERVICE nnte- nverinnci must he in numn mntor REPEAT CYCLE TIMER PUMP RUN LOW LEVEL EXTERNAL ALARM VOLTAGE: PHASE: HERTZ: HP/FLA: DIAGRAM 115V/230V 1 60 2/12 RECIRCULATION PUMP ENCLOSURE TYPE: 4X NO. 1 SIMPLEX SHORT CIRCUIT CURRENT: 5KA RCS1220 RMS SYMMETRICAL, 240V MAXIMUM NOTES: 1. 230V-10 OPERATION USE T1 AND T2 TO PUMP. 2. 115V-10 OPERATION USE T1 AND N TO PUMP. 3. MAX. HP FOR 115V-1 0 PUMP 1 HP. 4. MAX. HP FOR 230V-1 0 PUMP 2 HP. E-Z TREAT SIMPLEX CONTROL PANEL - 1 2 D-103 NITS �-1 100% 4" WELL CAP b BACKUP DISCONNECT NOTES: „ PRI RY LAMP LAMP UNION (TYP.) 4" 2" 2" 4„ 1. ULTRAVIOLET LIGHT PURIFIER b UV-102 BY E—Z TREAT. O 2. PROVIDE DUAL GFI RECEPTACLE 4" x 2" 17" 4" 2" FOR UNIT AND HEAT TAPE. FIELD REDUCER x ROUTE 2—#12,1—#12G, IN 3/4" a REDUCER 1/2" BALL PVC CONDUIT TO 120 VOLT SINGLE PHASE 20 AMP BREAKER VALVE AT Ani ISF 3. ORIENTATION PER SITE CONTROL n TOP VIEW �WITH ALARM REQUIREMENTS. 4. INSTALL 1/2" BALL VALVE FOR a SAMPLING DOWNSTREAM OF U.V. UNIT. a5 5. MAY LOCATE IN RECIRCULATION TANK IF ACCESS PROVIDED. 8I �I I �REDUCING E 71 .0 0 1 2" BAIL 4" x 2„ ///// ALVECn o REDUCER 4„ x 2„ '�� 30" DIA. REDUCER DISCONNECT s E—Z SET N UNION (TYP.) RISER HEAT PAD PRIMARY d 100% LAMP BACKUP LAMP tO NON —CORROSIVE REFLECTIVE AND /j \//j//j//j//j//j//j///,, WASHED #57 STONE n PROTECTIVE SLEEVE // n /\\ iv s= SECTION VIEW 3 ULTRAVIOLET DISINFECTION D-103 NITS L ALARM LIGHT Q O GROUND O O O O POWER BLOCK O O I 1 I 1 70m, N7M M1 VOLTAGE: 115V/230V PHASE: 1 HERTZ: 60 HP/FLA: 2/12 ENCLOSURE TYPE: 4X SHORT CIRCUIT CURRENT: 5KA RMS SYMMETRICAL, 240V MAXIMUM PUMP RUN HIGH LOW LEVEL O O O1 LIGHT LIGHT LIGHT ALARM HAND ON OFF OF AUTO TEST FIELD DOSING CONTROL PANEL (OR USE ORIGINAL DESIGN NTS O m 4 m m 3 O LS2 HIGH LEVEL m 2 m m 1 O LS1 LOW LEVEL ENCLOSURE 16X14 BACK PANEL LAYOUT NO. 1 SIMPLEX RCS1220 NOTES 1. SEE SHEETS C-105 AND D-101 FOR GENERAL NOTES THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING JUNE 289 2019 REVISIONS NO. DATE DESCRIPTION IPROJECT JPH TMANAGER: PROJECT ENGINEER: I DRAWN BY: LHB CHECKED BY: GSM DATE: DECEMBER 12, 2018 H11�I r ��4 AtI MacCONNELL & Associates, P. C. 1101 NOWELL ROAD, SUITE 118 — ` RALEIGH, NORTH CAROLINA 27607 P.O. BOX 129 LICENSE MORRISVILLE, NORTH CAROLINA 27560 NO. C-1039 TEL: (919) 467-1239 FAX: (919) 319-6510 BARBARA S. HUNTER AND FRANK W. ROCKHOLD LOT 16 CAROLINA CROSSINGS SUBDIVISION CHANGE OF TREATMENT TO E-Z TREAT SYSTEM CHATHAM COUNTY, NC DETAILS - 3 of 3 PROJECT NUMBER A35904.00 DRAWING NUMBER D-103 w Y) r In a w N w 0 z w w o' w 0 w c� Z a U I z 0 0 m In c� z 0 o' U z 0 a U 0 I 0 J 0 Y U 0 Y Z w 0 z a w Z z Q Q Q m 0 0 LO Q 435904.00 — BARBARA S, HUNTER AND FRANK W. ROCKHOLD — LOT 16 CAROLINA CROSSINGS SUBDIVISION — CHANGE OF TREATMENT TO E—Z TREAT SYSTEM