Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0083321_Renewal (Application)_20190530
ROY COOPER (i',... ,, V -_-4' Governor r J'" MICHAEL S.REEGAN . -.�.,; .I16 Secretary ""`�"""n LINDA CULPEPPER NORTH CAROLINA Director Environmental Quality July 18, 2019 Edward Caron Onslow Water and Sewer Authority 228 Georgetown Rd Jacksonville, NC 28540 Subject: Permit Renewal Application No. NC0083321 Hubert WTP Onslow County Dear Applicant: The Water Quality Permitting Section acknowledges the May 30, 2019 receipt of your permit renewal application and supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. Per G.S. 150E-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https://deo.nc.gov/permits-regulations/permit-guidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. Sincerely, Wren Thedford Administrative Assistant Water Quality Permitting Section ec: WQPS Laserfiche File w/application =�„l� Nortt.Caraliins D_psrtnti_nt of Enviranm_nta]Qua,ty I Di�nsbyn of V:ster ResoLro=_s -DE nn.rmv.y r ✓i1 titi'lmin ton Reob�n i Offce 1127 Carc;nal Dave Extens�n 11S79mington, North Csr��na 25405 {^ � "."" �, 910 7n-7215 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants Mail the complete application to: D/laeQ/DWb$ N. C. Department of Environment and Natural Resources Division of Water Quality / NPDES Unit HAY 3 0 2019 1617 Mail Service Center, Raleigh, NC 27699-1617 Water Quality Permitting Section NPDES Permit Number NC0083321 If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise,please print or type. 1. Contact Information: Owner Name Onslow Water and Sewer Authority Facility Name Hubert Water Treatment Plant Mailing Address 222 Georgetown Road City Jacksonville State / Zip Code NC 28546 Telephone Number (910)455-0722 Fax Number (910)455-2583 e-mail Address ecaron@onwasa.com 2. Location of facility producing discharge: Check here if same as above ❑ Street Address or State Road 374 Hubert Boulevard City Hubert State / Zip Code NC 28539 • County Onslow 3. Operator Information: Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Onslow Water Sewer Authority Mailing Address 222 Georgetown Road City Jacksonville State / Zip Code NC 28 Telephone Number (910)455-0722 Fax Number (910)455-2583 4. Ownership Status: Federal ❑ State ❑ Private ❑ Public Page 1 of 4 Version 5/2012 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants 5. Type of treatment plant: ® Conventional (Includes coagulation, flocculation, and sedimentation, usually followed by filtration and disinfection) ® Ion Exchange (Sodium Cycle Cationic ion exchange) ® Green Sand Filter (No sodium recharge) ❑ Membrane Technology (RO, nanofiltration) • Check here if the treatment process also uses a water softener rgi 6. Description of source water(s) (i.e. groundwater, surface water) Ground Water 7. Describe the treatment process(es) for the raw water: • Raw water goes thru aeration to remove sulfur. • Thru the Greensand filter to remove Iron and Manganese. • Thru the Ion Exchange softeners to remove calcium and Magnesium. • Hypochlorite is used for disinfection. • Fluoridation. • Phosphate for corrosion control. 8. Describe the wastewater and the treatment process(es) for wastewater generated by the facility: • The waste from the Greensand filters, ion exchange softeners is discharged to a series (four) sedimentation lagoons, supernatant is discharged to the receiving stream. 9. Number of separate discharge points: 1 Outfall Identification number(s) 001 10. Frequency of discharge: Continuous ® Intermittent ❑ If intermittent: Days per week discharge occurs: Duration: 11. Plant design potable flowrate 6 MGD Backwash or reject flow .30 MGD Average flow 12. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including latitude and longitude): Queen Creek, classified SA-HQW waters in the White Oak River Basin 13. Please list all water treatment additives, including cleaning chemicals or disinfection treatments, that have the potential to be discharged. Page 2 of 4 Version 5/2012 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants Alum / aluminum sulfate Yes No X Iron sulfate / ferrous sulfate Yes No X Fluoride Yes X No Ammonia nitrogen / Chloramines Yes No X Zinc-orthophosphate or sweetwater CP1236 Yes X No List any other additives below: KMnO4 Household Cleaners 14. Is this facility located on Indian country? (check one) Yes ❑ No 15. Additional Information: ➢ Provide a schematic of flow through the facility, include flow volumes at all points in the water treatment process. The plan should show the point[s] of addition for chemicals and all discharges routed to an outfall [including stormwater]. • ➢ Solids Handling Plan ➢ The plan is to clean a lagoon every three years 16. NEW Applicants Information needed in addition to items 1-15: ➢ New applicants are highly encouraged to contact a permit coordinator with the NCDENR Customer Service Center. Was the Customer Service Center contacted? ❑ Yes ❑ No ➢ Analyses of source water collected ➢ Engineering Alternative Analysis ➢ Discharges from Ion Exchange and Reverse Osmosis plants shall be evaluated using a water quality model. 17. Applicant Certification I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Edward Caron Superintendent Wastewater Printed name of Pe„son Signi g Title 5/0 7 Signature of Applicant Date Page 3 of 4 Version 5/2012 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants North Carolina General Statute 143-215.6(b)(2)provides that.Any person who knowingly makes any false statement representation,or certification in any application, record,report,plan,or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article,or who falsifies,tampers with,or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article,shall be guilty of a misdemeanor punishable by a fine not to exceed$25,000,or by imprisonment not to exceed six months,or by both (18 U S C Section 1001 provides a punishment by a fine of not more than$25,000 or impnsonment not more than 5 years,or both,for a similar offense) Page 4 of 4 Version 5/2012 Hubert WTP Water treatment Process 372 Hubert BLVD Aerators Avg Greensand Filters 1233 GPM each Avg Flow Per filter Approximately 350 GPM Filter Pumps Train 1 Hubert NC, 28539 Q. Det#3 �— 4. © © © 0 --H — •, NPDES #NC0083321 3 I KMN04 Injected � Train 2 Raw Water in at Detention tanks ©A AAA Flow AVG ' 2 - Det# 2 Train 3 3850 GPM Detention tanks • 0 0 ® ® '" lO-- Det#1 Backwash Waste to lagoons Ion Exchange Softeners Approximated Avg 15000gal waste Train 1 Softeners 1-2 AVG flow 440 GPM per backwash process per train. After filt� O ©Train 1 Soft. Bypass AVG 250 GPM Train 2 I Softener Bypass. y Chemical After Filt Treated Flow Injection vault 3 4 5 AVG Total Finished Water CW#1 High Service Pumps Train 3 . 1. HFS (fluoride) 3700 GPM to Clearwells After filter 2. PO4 (orthophosphate) —iii HSPs �'�_O" O • h 3. CL2 (Sodium hypochlorite)I� 1-4 to �-- Softeners 3-8 Avg 300 GPM0 _l f : System Trains 2-3 Soft. Bypass Avg 350gpm Softener Regeneration 1200 Gal.of Saturated Brine is Process waste to lagoon, applied per Softener Approx 18000 Gal per regeneration. Regen Plant Floor Drains and Storm Drains Floor Drains flowing to Lagoon: Chemical Feed To Waste Lagoon Lab/Office Floor & Lab Sink There are Four Bathroom Floor 24" x 24" Storm HFS room floor Drains Located CL2 and CL2 storage Room Floor E>To Retention Pond Behind Plant g inside the plant. I Blower Rm Floor CL2 feed Rm Floor Train Bay Floor Drains Please note that this schematic is a general representation of the WHubert WTP process only and is NOT depicting orientation or scale of the different components within or around the WTP facility. Discharge to stream [ /-4)11 , T' Lagoon #1 Lagoon#2 .-, Lagoon #3 m Primary Secondary Tertiary Lagoon #4 1 'r4 1 it Influent m _ Alternate Influent Plant w. ectio; Current floor drain discharee location. 372 Hubert Blvd. Hubert NC 28539 NPDES # NC0083321 -Each lagoon holds 0.75 MG -There is no chemical addition. WTP -Max influent flow is 1300 GPM as a batch feed. -Effluent vault has an 80gpm & a 350gpm pump. There are three alternate influent points Solids Handling Plan Hubert Water Treatment Plant A pump and haul method of removing solids from the four (4) lagoons at Hubert WTP will be utilized. Solids will be dewatered to pass the paint test and transported by truck to the Onslow County Landfill. The lagoons will be pumped every three (3) years so as not to allow solids accumulation to interfere with detention time.