Grady W Fulcher
Genesis Condominium Owners Association Inc.
PO Box 1154
Atlantic Beach, NC 28512-1154
SUBJECT: Compliance Inspection Report
Genesis Condos WWTF
Non -discharge Permit No. WQ0006863
Carteret County
Dear Permittee:
The North Carolina Division of Water Resources conducted an inspection of the Genesis Condos WWTF
on 6/26/2019. This inspection was conducted to verify that the facility is operating in compliance with
the conditions and limitations specified in Non -discharge Permit No. WQ0006863. The findings and
comments noted during this inspection are provided in the enclosed copy of the inspection report
entitled "Compliance Inspection Report". There were no significant issues or findings noted during the
inspection and therefore, a response to this inspection report is not required.
If you should have any questions, please do not hesitate to contact Helen Perez with the Water
Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at
helen.perez@ncdenr.gov.
Sincerely,
DocuSigned by:
I ONE �narrr�r)A.
7F141 for
E73B6F3456,.
Morella Sanchez -King, Regional Supervisor
Water Quality Regional Operations Section
Wilmington Regional Office
Division of Water Resources, NCDEQ
ATTACHMENTS
Cc: Uploaded to Laser fiche
David Godwin — electronic copy
Lee Buck — electronic copy
North CawEnsDepart mentofEnvironmeatalQua?rty I DiuisionofWater Resources
ZAD,Wilmington Reg•3iLa-Dffioe 1 127 C.ardirreiDrive Extenson I Winra:ngton, North; ar•xms28405
TQ� 910-796-7215
Comaliance Insaection Resort
Permit: WQ0006863 Effective: 07/09/10 Expiration: 05/31/16 Owner: Genesis Condominium Owners Association
Inc
SOC: Effective: Expiration: Facility: Genesis Condos WWTF
County: Carteret 301salter Path Rd
Region: Wilmington
Atlantic Beach NC 28512
Contact Person: Grady W Fulcher Title: Property Manager Phone: 252-247-2800
Directions to Facility:
From Kinston, take State Route 58 south approximately 50 miles to the bridge across Bogue Sound. Proceed another 13 miles on
State Route 58 to Bogue Banks. The facility is directly across from the entrance to the NC Aquarium at Pine Knoll Shores.
System Classifications: WW2,
Primary ORC: Stanley Earl Buck Certification: 993396 Phone: 252-503-5307
Secondary ORC(s):
On -Site Representative(s):
On -site representative
Related Permits:
Inspection Date: 06/26/2019
Primary Inspector: Helen I Perez
Secondary Inspector(s):
Stanley E Buck
Entry Time: 10:40AM Exit Time: 11:40AM
252-503-5307
Phone: 910-796-7387
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: High Rate Infiltration
Facility Status: Compliant Not Compliant
Question Areas:
Treatment Flow Measurement -Effluent Treatment Flow Measurement -Influent Miscellaneous Questions
Treatment Flow Measurement -Water Treatment Record Keeping
Use Records
Treatment Influent Pump Station Treatment Disinfection End Use -Infiltration
Treatment Flow Measurement Standby Power
(See attachment summary)
Page 1 of 6
Permit: WQ0006863 Owner - Facility: Genesis Condominium Owners Association Inc
Inspection Date: 06/26/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
A routine compliance inspection of Genesis WWTF was conducted on June 26, 2019. The purpose of the evaluation was to
verify that the facility is operating in compliance and limitations specified in Permit W00006863. Lee Buck, ORC, Don
O'Mara, Karrie O'Mara and the Permittee, David Godwin, were present during the inspection.
The Genesis Condominium complex received extensive damage during Hurricane Florence. Currently there are 3 condos
being occupied by permanent residents at the complex during the repair work. Staff indicated that approximately one batch
a day of wastewater is being treated through the sequencing batch reactor (SBR) system. Under normal conditions, two
trains of the SBR are operational during the summer season and one train in the winter. Solids are removed twice a year by
Barnes Environmental. Existing facilities were approved without tertiary filtration and aeration in the EQ tank, but do appear
to cause any issues.
A file review of the monitoring reports was conducted since the last inspection. Monitoring wells have been compliant except
for some high TDS values which can be typical in a barrier island environment. There have been numerous months where
NDMRs and NDARs have been late or not submitted. WIRO has made contact by phone and email many times as a
reminder to submit. This issue was discussed with Mr.Godwin during the inspection and emphasized that WIRO will begin
issuing violations if this continues.
This permit expired on 5/31/2016 and no renewal application has been received by the Central Office. It was discussed with
Mr. Godwin that operating without a active permit is a violation, and a renewal application needs to be submitted as soon as
possible.
This facility is compliant with non -discharge permit WQ0006863. Please review the comment sections of the inspection
report for more details.
Page 2 of 6
Permit: WQ0006863
Inspection Date: 06/26/2019
Owner - Facility: Genesis Condominium Owners Association Inc
Inspection Type : Compliance Evaluation Reason for Visit: Routine
Type
Yes No NA NE
Activated Sludge Drip, LR
❑
Reuse (Quality)
❑
Recycle/Reuse
❑
Single Family Drip
❑
Lagoon Spray, LR
❑
Single Family Spray, LR
❑
Activated Sludge Spray, LR
❑
Activated Sludge Spray, HR
❑
Infiltration System
Treatment Yes No NA NE
Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑
Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑
Comment: No comment.
Treatment Influent Pump Station
Yes No NA NE
Is the pump station free of bypass lines or structures?
❑ ❑ ❑
Is the general housekeeping acceptable?
❑ ❑ ❑
Are all pumps present?
❑ ❑ ❑
Are all pumps operable?
❑ ❑ ❑
Are floats/controls operable?
0
❑ ❑ ❑
Are audio and visual alarms available?
❑ ❑ ❑
Are audio and visual alarms operational?
❑ ❑ ❑
# Are SCADA/Telemetry alarms required?
❑
❑ ❑
Are SCADA/Telemetry available?
❑
❑ ❑
Are SCADA/Telemetry operational?
❑
❑ 0 ❑
Comment: Telemetry is not required but is available and operational. Audio and visual alarms were
operational and visual alarm is located outside restricted access fence so it can be seen from
the road. The pump station is inspected weekly and documented on weekly check sheets.
Treatment Flow Measurement -Influent
Yes No NA NE
Is flowmeter calibrated annually?
❑
❑ 0 ❑
Is flowmeter operating properly?
❑
❑ 0 ❑
Does flowmeter monitor continuously?
❑
❑ 0 ❑
Does flowmeter record flow?
❑
❑ 0 ❑
Does flowmeter appear to monitor accurately?
❑
❑ ❑
Comment
Page 3 of 6
Permit: WO0006863 Owner - Facility: Genesis Condominium Owners Association Inc
Inspection Date: 06/26/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Treatment Flow Measurement -Water Use Records
Is water use metered?
Are the daily average values properly calculated?
Comment:
Treatment Flow Measurement -Effluent
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Comment: The flow meter was calibrated on 5/18/2019 by Delta Systems.
Standby Power
Is automatically activated standby power available?
Is generator tested weekly by interrupting primary power source?
Is generator operable?
Does generator have adequate fuel?
Comment: The generator is tested weekly and documented on
all the facilities that they operate.
Treatment Disinfection
Is the system working?
Do the fecal coliform results indicate proper disinfection?
Is there adequate detention time (-30 minutes)?
Is the system properly maintained?
If gas, does the cylinder storage appear safe?
Is the fan in the chlorine feed room and storage area operable?
Is the chlorinator accessible?
If tablets, are tablets present?
Are the tablets the proper size and type?
Is contact chamber free of sludge, solids, and growth?
If UV. are extra UV bulbs available?
If UV, is the UV intensity adequate?
# Is it a dual feed system?
Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)?
If yes, then is there a Risk Management Plan on site?
If yes, then what is the EPA twelve digit ID Number? (1000 )
Yes No NA NE
Yes No NA NE
■❑❑❑
❑❑❑■
■❑❑❑
■❑❑❑
❑ ❑ ❑
Yes No NA NE
❑❑❑■
❑❑❑■
sheets that includes aenerators for
Yes No NA NE
❑❑■❑
■❑❑❑
❑❑■❑
❑❑0❑
❑❑❑■
■❑❑❑
❑❑■❑
❑❑■❑
Page 4 of 6
Permit: WQ0006863 Owner - Facility: Genesis Condominium Owners Association Inc
Inspection Date: 06/26/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine
If yes, then when was the RMP last updated?
Comment: No comment.
Record Keeping
Yes No NA NE
Is a copy of current permit available?
0
❑ ❑ ❑
Are monitoring reports present: NDMR?
❑ ❑ ❑
NDAR?
❑ ❑ ❑
Are flow rates less than of permitted flow?
❑ ❑ ❑
Are flow rates less than of permitted flow?
❑ ❑ ❑
Are application rates adhered to?
❑ ❑ ❑
Is GW monitoring being conducted, if required (GW-59s submitted)?
❑ ❑ ❑
Are all samples analyzed for all required parameters?
❑ ❑ ❑
Are there any 2L GW quality violations?
❑
❑ ❑
Is GW-59A certification form completed for facility?
❑
❑ ❑
Is effluent sampled for same parameters as GW?
❑ ❑ ❑
Do effluent concentrations exceed GW standards?
❑
❑ ❑
Are annual soil reports available?
❑
❑ ❑
# Are PAN records required?
❑
❑ ❑
# Did last soil report indicate a need for lime?
❑
❑ ❑
If so, has it been applied?
❑
❑ ❑
Are operational logs present?
❑ ❑ ❑
Are lab sheets available for review?
❑ ❑ ❑
Do lab sheets support data reported on NDMR?
❑ ❑ ❑
Do lab sheets support data reported on GW-59s?
❑
❑ ❑
Are Operational and Maintenance records present?
❑ ❑ ❑
Were Operational and Maintenance records complete?
❑ ❑ ❑
Has permittee been free of public complaints in last 12 months?
❑ ❑ ❑
Is a copy of the SOC readily available?
❑
❑ 0 ❑
No treatment units bypassed since last inspection?
0
❑ ❑ ❑
Comment: Operational and maintenance records were organized and complete.
Staff uses Environmental
1, certification #3, for analyzing non -field parameters. The ORC,
Lee Buck, is field certified,
certification #5660. Calibrations for the pH meter are recorded on daily sheets.
End Use -Infiltration Yes No NA NE
# Is the application High Rate or Low Rate? High Rate
Are buffers maintained? ❑ ❑ ❑
Are any supply wells within the CB? ❑ ❑ ❑
Are any supply wells within 250' of the CB? ❑ ❑ ❑
Page 5 of 6
Permit: WO0006863 Owner - Facility: Genesis Condominium Owners Association Inc
Inspection Date: 06/26/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Is municipal water available in the area?
❑ ❑ ❑
Are GW monitoring wells required?
❑ ❑ ❑
Are GW monitoring wells located properly w/ respect to RIB and CB?
❑
❑ ❑
Are GW monitoring wells properly constructed, including screened interval?
❑
❑ ❑
Is a usable green area maintained?
❑
❑ ❑
Is the disposal site acceptable?
❑ ❑ ❑
Is the distribution equipment acceptable?
❑ ❑ ❑
Is the disposal site free of ponding?
❑ ❑ ❑
Is the disposal site free of breakout?
❑ ❑ ❑
Are the disposal sites free of solids, algae, etc.?
❑ ❑ ❑
Do the records show that the fields are properly maintained?
❑ ❑ ❑
Are the disposal sites free of vegetation?
❑ ❑ ❑
Do any surface water features appear to be adversely impacted by GW discharge?
❑
❑ ❑
No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.?
0
❑ ❑ ❑
Comment: The 2 infiltration fields are dosed one at a time so flow can be measured by
flow meter. Fields
are maintained by the condo complex landscaping crew. Dosing tank pumps
are undersized
which causes insufficient flow to fields.
Page 6 of 6