Loading...
HomeMy WebLinkAboutWQ0040933_Application (FTSE)_20190710Central Files: APS ___®. SVVP - 6/11/2019 Permit Number WQ0040933 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dean.hunkele Coastal SWRule Facility Faciflty Name Hilltop Townes Owner Owner Name Brunswick Regional Water and Sewer H2go Version Permit Classification A Individual Permit Contact Affiliation Major/Minor Region Minor Wilmington County Brunswick Facility Contact Affiliation Owner Type Government - County Owner Affiliation Robert Walker KOX*. �_Il Dates/Events Leland NC 28451223 Scheduled Odg Issue App Received Draft Initiated Issuance Public Notice Issue 6/10/2019 Regulated Activities aecluested lReceived Events Additional information requested AAAi+i --- I ;,f­­fi­ ­i".H ........... To. NCDEQ Date - ' 6/10/19 127 K Cardinal Drive Wilmington, NC 28405 Re: Hilltop 'Townes 910) 796-7215 Fast Track Sewer � Attn: Dean Hunkele Project No. I 18422.PE e ale sends Originals ED Prints ❑ Shop Drawings ❑ Calculations ❑ Correspondence ❑ Plans ❑ Specifications ® Other as listed below he 4'bllowin itcmx s. Quantity Date Iow a No. Description 2 Fast Track Sewer Permit ETA 04-16 2 Flow Tracking/Acceptance Sewer Extension Application FTSE 10-18 E12G0 and Brunswick County) 1 Sanitary Sewer Narrative including vicinity map and USGS Map 1 $480 check Issue Statuso 0 For Approval As Requested ❑ Construction ❑ Bid ❑ For Your Use 0 For Review and Comment ❑ Approved as Noted ❑ See Remarks etion Take s ❑ No Exceptions Taken ❑ Make Corrections Noted ❑ Amend & Resubmit ® Rejected -See Remarks ❑ Approved as Submitted ❑] Other IZ.e� Fast Track Sewer Submittal Hilltop Townes Ca Signed:' Tim Clinkscales, PE, PLS State of Forth Carolina Department of Environmental Quality 51 xDivision Of Water Resources µ 15A NCAC 02T 90300 — FAST TRACK SEWER. SYSTEM EXTENSION APPLICATION Division of Water Ptesources F'TA 04-16 & SUPPORTING DOCUMENTATION Application Number -i ' ' U rG (to be completed by Dwx) 1. Applicant's name: Brunswick Regional Water & Sewer H2CO (company, municipality, HOA, utility, etc.) 2. Applicant type: F1 Individual El Corporation 0 General Partnership [l Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Bob Walker per = - 0_ Title: Executive Manager 4. Applicant's mailing address: PO Box 2230 City: Leland State: NC Zip: 28451- 5. Applicant's contact information: Phone number: (9t0) 371-6441 Email Address: bwaiker(a),h22oonline.com 1. Project name: Hilltop Townes 2. Application/Project status: ® Proposed (New Permit) El Existing Perinit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Brunswick 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.258° Longitude:-78.053' 5. Parcel ID (if applicable): 02900001 (or Parcel ID to closest downstream sewer) 1. Professional Engineer: Tim Clinkscales License Number: 028847 Firm: Paramou.nte En2incerin2, Inc. Mailing address: 122 Cinema Drive City: Wilmington State: NC Zip: 28403- Phone number: (910)191-6707 Email Address: tclinikscalesat)aramounte-eng.com 1. Facility Name: Northeast Regional WWTP Owner Name: Brunswick County V. RECEIVING DOWNSTREAM SEWED INFORMATION (if different than TF')a 1. Permit Number(s): WQ00168554 (m) Downstream (Receiving) Sewer Size: $inch System Wide Collection System Permit Number(s) (if applicable): WQCS00202 Owner Name(s): Brunswick Regional Water and Sewer H2CiO FORM: FTA 04-16 Page 1 of 5 F"IFETFEW, L If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? 2. If the Applicant is a Developer of lots to be sold, has a I-X been attached? 1 If the Applicant is a been attached? MONFRI•M 4. Origin of wastewater: (check all that apply): ED Residential. Owned R Retail (stores, centers, malls) ❑ Car Wash E] Residential Leased El Retail with food preparation/service El Hotel and/or Motels R School / preschool / day care R Medical / dental / veterinary facilities El Swimming Pool /Clubhouse EJ Food and drink facilities F] Church El Swimming Pool/Filter Backwash E] Businesses / offices / factories El Nursing Home El Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial k % Industrial (St-c PA',' "Is there a Pretreatment Program in effect? El Yes [:]No 6. Has a flow reduction been approved under P" C 4�'1`1'11? Z Yes [:1 No > If ves, vrovidLaLcoRv of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see -0,21P Q Daily Design Flow 0 No. of Units Flow Townhomes 210 gal/unit 168 35,280 GPD Clubhouse 5 gal/seat 86 430 GPD Pool Area 10 gal/person 70 700 GPD gal/ GPD gal/ GPD gal/ GPD Dotal 36,410 GPD a See A ' C z" 2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in c,2A­,,A b Per 15A NCAC 02T .0 1 14(c), design flow rates for establishments not identified [in table i A T" 0',', 'P � i-I ' 1 1 - 4 " ] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 36,410 GrPD (per r= 2 1' > Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: El Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line El Flow has already been allocated in Permit Number: El Rehabilitation or replacement of existing sewer with no new flow expected El Other (Explain): FORM: FTA 04-16 Page 2 of 5 I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 3,650 PVC I • Section 11 & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria • Section III contains information related to minimum slopes for gravity sewer(s) • Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC 1. Pump station number or name: 1 2. Approximate Coordinates (Decimal Degrees): Latitude: 34.257' Longitude: -78.054' 3. Design flow of the pump station: 0.03641 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 80 gallons per minute at 48 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 3 1750 PVC 6. Power reliability in accordance with - -",-A 1`A` ­­1 _ -1 11 ----------- E] Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B),' > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: El Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(I)(C) or [I Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(I)(C): > It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 Hill VU illill Hill ill: I 1. Does the project comply with all separations found in > 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer ystems: FF04-N • Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet "Any private or public water supply source, including any wells, WS-1 waters of Class 1 or Class 100 feet "Waters classified WS (except WS-I or WS-V), B, SA, (TRW, HQW, or S13 from normal high water or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet An basement 10 feet To slope of embankment or cuts of 2 feet or more vertical heig --it 10 feet Drama 5 feet Any swimming pooh, 10 feet Final earth grade (vertical)36 inches > contains alternatives where separations in Q 2T, 3, f), cannot be achieved. > "Stream classifications can be identified using the Division's > If noncompliance with "D" see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) E]Yes M No );> See the Division's draft separation requirements for situations where separation cannot be meet > No variance is required if the alternative design criteria specified is utilized in design and construction > As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per Yes No This would include Trout Buffered Streams per 4. Does the project comply with an individual 404 Permit or any 401 Certifications? 0 Yes n No > Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters > Information can be obtained from the A t, 5. Does project comply with A , N-"AC (additional permits/certifications)? NORMAN= Per -- i, U directly related environmental permits or certification applications are being prepared, have ------- ------- been applied for, or have been obtained, Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" - � I , I � JU�j�­ � Per "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. El Yes ED No > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location), FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with the and as applicable? Yes Q No If No., complete and submit the Variance/Alternative Design Request application (VADC 10- 14) and supporting documents for review. ADDroval of the re uest is required -prior to sub mittal_of the Fast Track ADnlication and suDDordne documents. 2. Professional Engineer's Certification: attest that this application for (Professional Engineer's name from Application Item 111. 1.) M has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Selver Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $ 10,000, as well as civil penalties up to $25,000 per violation, 3. Applicant's Certification per 15ANCAC 02T .0106; b): (Signature Authority's name & title from Application Item 1.3.) ��" c-lv-rattest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes and 2, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: C Date: FORM: ETA 04-16 Page 5 of 5 State of North Carolina DeDartment of Environmenta ua I M Flow Tracking for Sewer Extension Applications (FTSE 1-1 ) Entity Requesting Allocation: Brunswick Regional Water & Sewer Project Name for which flow is being requested: Hilltop Terraces Xforeffian oue 17SEmqv be required fair a shigle project if the metier of the HIWTP is not respousiblefor all pump stations aloitg the route of theproposed ivastewaterj7ow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Northeast Brunswick WWTP b. WWTP Facility Pem-nt #: WQ 0086819 AlIflonys are in MGD c. WWTP facility's permitted flow 2.475 d. Estimated obligated flow not yet tributary to the WWTP 2.187 e. WWTP facility's actual avg. flow 1.952 f Total flow for this specific request 0.03641 g. Total actual and obligated flows to the facility 4.175 h. Percent of permitted flow used 168.7% 11. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+Q (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Cut -rent Station Station Firm Daily Flow" Current Tributary Flow Plus (Name or Permit Capacity, (Finn / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** Downstream Facility Name (Sewer): Downstream Permit Number: Page I of 6 17-11-s [", 1 0- 11-11 111. Certification Statement: I William L. Pinnix, Dir of Engr certify to the best of my knowledge that the addition orf atma =77MEr ac-carTIMIC THUITTLy UNT Uldt Lne 110 related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implernentation of the planned improvernents identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and 11 plus all attached planning assessment addenduins for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Qf .ficial Sian ature Title qf�Signing Qf .ficial Approved 0 Form. D-' 8 Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Brun&wick-,-Rqgglad 7W'-"&---S-'----Hi-6-0 L Project Name for which flow is being requested: Hilltop Townes More than one FTSE maybe requiredfor a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewaterflow. a. WWTP Facility Name: Northeast Regional WWTP b, WWTP Facility Permit #: NC0086819 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the NVWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used •IT M.• R&11�6 List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Average Approx. Obligated, Pump Pump Daily Current Not Yet Total Current Station Station Firm Flow" Avg. Daily Tributary Flow Plus (Name or Permit Capacity, (Finn / pf), Flow, Daily Flow, Obligated Available Number) No. MGD MGD MGD MGD Flow Capacity*** 8 WQ0016854 0.605 0.242 0.089 0.086 0.175 0.067 The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2,02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer)- Brunswick Regional Water & Sewer Downstream Permit Number: WQ0016854 (M) FTSE 1.0-18 111. Certification Statement: certify, to the best of in\, knowledge that the addition of the volume ofv-,,raste,",ater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sev,-er overflows or overburden any downstream pump station en route to the receiviri'a treatment plant under normal circumstances,. given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and 11 plus all attached planning assessment addendun-is for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Sigming Qf cl ficicil Sianature 11�--P-C�110r�e e ofSigningQ1 ,ficial -/ 7- Date Page 2 of 6 FTSE 10-18 [Rim Prepared for: Prepared by: PARAMOUNTE G N <-- I N F-= F-= R I PQ C-- I I N C-- . 122 Cinema Drive Wilmington, NC 284003 Project #18442.PE May 2019 PROJECT NARRATIVE Sunset Land Investments, LLC is proposing a 168 unit townhome subdivision along with clubhouse and pool on the 28 acre parcel located between Mt Nfisery Road and Village Road in Brunswick County. The project will be served by gravity internally to a pump station that will pump to an existing manhole on our property just south of John Carter Road. The forcernain and collection line will be owned and maintained by the H2GO. The flow for the project ,vill be 36,410 GPD as provided. The length of line is as follows: 3650 LF of 8-inch gravity and 1750 LF of 3-inch forcemain, The operating point of the pump station will be 80 gpm @ 48 TDH. The forcemain and gravity sewer that are within 50' of wetlands will meet the alternate design criteria was used in design and will be constructed in same manner. Mle Map$ 34-15'28.8"N 78-OSIUM Map data @2019 500 ft 6/11/2019