HomeMy WebLinkAboutWQ0040198_Application (FTSE)_20190701 Central Files. APS _ SWP '—'--`-�� 7/2/2019 Permit Number (Wg0040198 Permit Tracking Slip Program Category Status Project Type Non-discharge In review Major modification Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations,8 Pressure Sewer Extensions B Individual Primary Reviewer Permit Contact Affiliation helen.perez Coastal SWRule Permitted Flow 8,700 Facility Facility Name Major/Minor Region Glow Academy Private Sewer Minor Wilmington Location Address County New Hanover Facility Contact Affiliation Owner Owner Name Owner Type Glow NC Inc Non-Government Owner Affiliation Todd Godbey PO Box 7621 Dates/Events Wilmington NC 28406762 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 8/13/2018 71112019 , MONTEITH CONSTRUCTION CORP. •WILMINGTON,NC 28401 CLH design, p.a. RECEIVED/NCDENR/M 400 Regency Forest Drive,Suite 120 Cary,North Carolina 27518 JUL 01 Z019 P:919.319.6716 www.clhdesignpa.com Water Quality Regional Operations Section \ imM1oo . n Letter of Transmittal June 28,2019 CLH Project Number: 17-140 To: Dean Hunkele Company: Water Quality Regional Operations Section - Division of Water Resources Address: 127 Cardinal Drive Ext City/State/Zip: Wilmington, NC 28405 Method: UPS Subject: GLOW Academy-Modification to Private Sewer Permit W00040198 Prints X Originals Specifications Applications Reports Copy of Submittals Other: x Letter Copies Date Description 1 06/28/19 Cover Letter 1 06/28/19 $480 Review Fee 1 06/28/19 Fast Track Application 1 06/28/19 Site Maps 1 06/28/19 Existing Permit and letter of modification to the pipe length Additional Remarks: Please accept the attached documents for review and approval of the modification to the private sewer permit to serve GLOW Academy in Wilmington, North Carolina. Please call or email Zak Pierce (zpier�gnpa com)with any questions or if you need additional information. Thank you. Signed: Zak Pierce Cc: File CLH design,p.a. State of North Carolina Department of Environmental Quality DWR Division of Water Resources 15A NCAC 02T .0300—FAST TRACK SEVER SYSTEM EXTENSION APPLICATION Dlvlslon of Water Resources ETA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DwR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: 1. Applicant's name: Glow NC, Inc. (company, municipality, HOA, utility,etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately-Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: Todd Godbev per 15A NCAC 02T .0106(b) Title: CEO 4. Applicant's mailing address: P.O. Box 7621 City: Wilmington State: NC Zip: 28406- 5. Applicant's contact information: Phone number: (910) 338-5258 Email Address: tgodbev a glowacademy.net IL PROJECT INFORMATION: L Project name: Glow New School Building 2. Application/Project status: ❑ Proposed(New Permit) ® Existing Permit/Project If a modification,provide the existing permit number: W00040198 and issued date: August 13, 2018 If new construction but part of a master plan, provide the existing permit number: W000 3. County where project is located: New Hanover 4. Approximate Coordinates(Decimal Degrees): Latitude: 34.2521' Longitude: -77.8986' 5. Parcel ID (if applicable): 3138-24-9548 (or Parcel ID to closest downstream sewer) Ill. CONSULTANT INFORMATION: 1. Professional Engineer: Kenneth A .Loring License Number: 23953 Firm: CLH Design p.a. Mailing address: 400 Regenev Forest Drive Suite 120 City: Cary State: NC Zip: 27518-8599 Phone number: (919)319-6716 Email Address: Mot ingL&clhdesignpa.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: James A. Loughlin(NSW WTF) Permit Number: NCO023965 Owner Name: CFPUA V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if aliplicable): WQCS Owner Name(s): CFPUA FORM: FTA 04-16 Page I of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately-Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement(FORM: DEV)been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association has an Operational Agreement (FORM: HOA)been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ® School/preschool/day care ❑ Medical/dental/veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses/offices/factories ❑ Nursing Home ❑ Other(Explain in Attachment) 5. Nature of wastewater : 100 % Domestic/Commercial % Commercial % Industrial (Sec 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .01 14(fl? ❑ Yes ® No ➢ If yes, provide a coo,of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type(see 021.OI14(ffl Daily Design Flow °° No. of Units Flow Schools w/Cafeteria 12 gal/student 725 8,700 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 8,700 GPD a See 15A NCAC 02T .0114(b) (d) (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling;proposed unknown non-residential development uses;public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c),design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns,and other measured data. 8. Wastewater generated by project: 88 700 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other(Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA(If Applicable)-02T.0305 & MDC (Gravity Servers): 1. Summarize gravity sewer to be permitted: Size(inches) Length(feet) Material 8" 1,335 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet mininuun slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable)—02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT L Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - ° 3. Design flow of the pump station: millions gallons per day(firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size(inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry- 15A NCAC 02T .0305(h)(1)(13)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per clay ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick-connection receptacle and telemetry- 15A NCAC 02T 0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry- 15A NCAC 02T .0305(h)(l)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant(draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations,au evaluation of all the pump stations'storage capacities and the rotation schedule of the portable power source or pump, including travel timefiames, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS& SEPARATIONS—(02B .0200 & 15A NCAC 02T.0305(f)): I. Does the project comply with all separations found in 15A NCAC 02T .0305(1)&(e) ® Yes ❑ No ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewers stems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below(vertical) 24 inches Water mains vertical-water over sewer including in benched trenches) I8 inches Water mains (horizontal) 10 feet Reclaimed water lines vertical- reclaimed over sewer) 18 inches Reclaimed water lines horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class 1 or Class 11 impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high h water or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth glade(vertical) 36 inches ➢ 15A NCAC 02T.0305(9) contains alternatives where separations in 02T.0305(fl cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webnal!c ➢ If noncompliance with 02T.0305(fl or(c), see Section X of this application 2. Does the project comply with separation requirements for wetlands'? (50 feet of separation) ❑ Yes ❑ No ® N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ® N/A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6)(additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high-priority?" Per 15A NCAC 02T.0402, "high-priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ®No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial tine, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six-months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System-Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A N(;i'.k12T, the lvlil!iputinl-I>4�igii CC raria lot [lie 1'grI!Sil(ing-i1l')'ump tilmions ;Ind Ford�1�LIh(Inlet_�u19!),and the(irpv_i3y,fewer plit�impnLDe,sigp C uqu i_!(I;!Icu scr,ign)as applicable'? ® Yes ❑ No If No,complete and submit the Varimicc/Allemativc Design Request application(VADC 10-14)and supporting documents for review. APDroval of the request Is reuub'ed urior to submittal of the Fast'trnck Aoo0etlot and sortmrllne docuntentx 2. professional Engineer's Certification: h ./ern+ A'_ Lat),A j __...._ aucst that this application for (Professional Frigineer's name from Application Item II1.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans,specifications, engineering calculations,and all other supporting documentation to the best of my knowledge 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravily Sewer Minimum Design Criteria for Gravity Sewers(latest version),and the Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and havejudged it to be consistent with the proposed design. NO'I'F. — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine nol to exceed$10,000,as well as civil penalties up to$25,000 per viohtiotkarN'C�,�R •,' P� North Carolina Professional Engineer's seal,signature,and dear. � .:pFE5SjO.y•��q :'QQ 9� d SEAL2395 OINFr�P ��fft` 3. Applicant's Certification per 15A NCAC 021 _0106(b)t I, Todd Godbey, CEO mtcsi that this application for (Signature Authority's name&title from Application Item 1.3,) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non- discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief,and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also unelersland that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes ,1,13-215.6?A and 1.11-215.613, any person who knowingly makes may false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a tine not to exceed $10,000 as well as civil penalties up to$25,000 per violation. Todd Godbey ' „ . . Signature: Date: State of North Carolina Department of Environmental Quality DWR Division of Water Resources 15A NCAC 02T .0300— FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Dlvlslon of Water Resources INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION _ L _- ...11G. yip 1/ 74 GREENTR f ,MARTIN LUTHER KING J R, PKW„Y $: 74 7 J DOWNSTREAM , s �� CONNECTION POINT �. LLJOYQ ti, cr _j 2 MCCLEJ-U0 > : DD DRCC / o P INCESS PLACE DR `t OP Q v QUAD MAP: WILMINGTON, CASTLE HAYNE DATE: 2016 SCALE: 1" = 1000' GLO AmdeW WILMINGTON, NC CLH DESIGN P.A. DATE: JULY 2018 Regency Park PROJECT NO. 17.140 400 Regency Forest Drive Suite 120 Cary, North Carolina 27518 NNEW HANOVER COUNTY QUAD MAP Phone: (919) 319- 18 Fax: 919) 319-75 16 if \14t 2 ) V W ' 1 1 W ,po LU co �-�� � 4 `� to _ - � �'��' {•�� WJ Ei t,y. ♦ ,. S y A b �_•�- ��%` ce 30N3� \- t ' : N3r �„��, ` > �{gam„ �;; = y,�; Y, 4, � J t>n: , NCDWQ Past-Track Application Attachment— Project Narrative Project: Glow Academy—New School Building Owner: GLOW NC, Inc. Engineer: CLH Design, PA Date: 03-July-2018 A new private elementary school is proposed at 2100 Sunglow Drive in Wilmington, NC. A gravity sewer extension will be required to serve the new facilities. The school building will be sized for 725 students. Applying the"Elementary School" wastewater design flow rate of 12-gpd per student, the expected Average Daily Flow for the facility is 8,700-gpd. The nearest public sewer, an existing 8-in gravity sewer main is owned and operated by CFPUA, and exists in Manly Avenue to the west of the proposed school site. The system eventually flows to CFPUA's James A. Loughlin Wastewater Treatment Facility (NC0023965). An 8-in gravity sewer system is proposed to convey wastewater from the school building to the existing public gravity sewer in Manly Avenue. No wetlands or streams exist within 100-ft of the proposed sewer lines or pump station.