HomeMy WebLinkAboutNC0025836_Inspection_20190701EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0025836 19/07/01 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Hot Springs WWTP Bridge St Hot Springs NC 28743 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 01:30PM 19/07/01 15/12/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data 02:30PM 19/07/01 20/09/30 Name, Address of Responsible Official/Title/Phone and Fax Number Randy A Joseph,PO Box 218 Hot Springs NC 287430218//828-622-7591/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Facility Site Review Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Daniel J Boss ARO WQ//828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: F4A18603-95C5-4B08-8D5C-D5D52FA84065 7/8/2019 7/8/2019 NPDES yr/mo/day 19/07/01 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) This was a follow up inspection to the compliance evaluation inspection on 1/26/2018. I met with Randy Joseph (ORC) and Jeremy Trantham for the inspection. The center well was clear of solids, the settleability was at an acceptable level, and the rags from the bar screen are better contained now. The return lines are still shooting sludge onto the catwalk, and two of the air diffusers are still not functioning at the WWTP. These items were noted in the previous inspection and need to be repaired. The clarifier weirs still had a lot of algae on them. Mr. Joseph said he would work on cleaning those up using a hose. NC0025836 17 (Cont.) Page#2 DocuSign Envelope ID: F4A18603-95C5-4B08-8D5C-D5D52FA84065 Permit:NC0025836 Inspection Date:07/01/2019 Owner - Facility: Inspection Type: Hot Springs WWTP Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? The plant has 3 return ports that are shooting return sludge onto the catwalk leading to the clarifier. Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin’s surface? Is the DO level acceptable? Page#3 DocuSign Envelope ID: F4A18603-95C5-4B08-8D5C-D5D52FA84065 Permit:NC0025836 Inspection Date:07/01/2019 Owner - Facility: Inspection Type: Hot Springs WWTP Compliance Evaluation Aeration Basins Yes No NA NE Is the DO level acceptable?(1.0 to 3.0 mg/l) Two of the eight diffusers are not functioning. This was first noted in the 2018 inspection. Settleability in the aeration basin was 46% in 30 minutes. Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth) The weirs should be cleaned more often, there was a lot of algae buildup on them.Comment: Disinfection-Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? (Sodium Hypochlorite) Is pump feed system operational? Is bulk storage tank containment area adequate? (free of leaks/open drains) Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? The chlorine contact chamber is very rusted and should probably be refurbished or replaced. Comment: De-chlorination Yes No NA NE Type of system ?Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de-chlorination substance stored away from chlorine containers? Comment: Page#4 DocuSign Envelope ID: F4A18603-95C5-4B08-8D5C-D5D52FA84065 Permit:NC0025836 Inspection Date:07/01/2019 Owner - Facility: Inspection Type: Hot Springs WWTP Compliance Evaluation De-chlorination Yes No NA NE Are the tablets the proper size and type? Are tablet de-chlorinators operational? Number of tubes in use? Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Page#5 DocuSign Envelope ID: F4A18603-95C5-4B08-8D5C-D5D52FA84065