Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 N 52 NC0025836 19/07/01 C S31112171819 20
21 66
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved-------------------
N67707172 73 74 75 80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Hot Springs WWTP
Bridge St
Hot Springs NC 28743
Entry Time/Date Permit Effective Date
Exit Time/Date Permit Expiration Date
01:30PM 19/07/01 15/12/01
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Other Facility Data
02:30PM 19/07/01 20/09/30
Name, Address of Responsible Official/Title/Phone and Fax Number
Randy A Joseph,PO Box 218 Hot Springs NC 287430218//828-622-7591/Contacted
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Facility Site Review
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date
Daniel J Boss ARO WQ//828-296-4658/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#1
DocuSign Envelope ID: F4A18603-95C5-4B08-8D5C-D5D52FA84065
7/8/2019
7/8/2019
NPDES yr/mo/day
19/07/01
Inspection Type
C3111218
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
This was a follow up inspection to the compliance evaluation inspection on 1/26/2018. I met with
Randy Joseph (ORC) and Jeremy Trantham for the inspection.
The center well was clear of solids, the settleability was at an acceptable level, and the rags from the
bar screen are better contained now.
The return lines are still shooting sludge onto the catwalk, and two of the air diffusers are still not
functioning at the WWTP. These items were noted in the previous inspection and need to be repaired.
The clarifier weirs still had a lot of algae on them. Mr. Joseph said he would work on cleaning those up
using a hose.
NC0025836 17 (Cont.)
Page#2
DocuSign Envelope ID: F4A18603-95C5-4B08-8D5C-D5D52FA84065
Permit:NC0025836
Inspection Date:07/01/2019
Owner - Facility:
Inspection Type:
Hot Springs WWTP
Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
The plant has 3 return ports that are shooting return sludge onto the catwalk leading to the
clarifier.
Comment:
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Comment:
Bar Screens Yes No NA NE
Type of bar screen
a.Manual
b.Mechanical
Are the bars adequately screening debris?
Is the screen free of excessive debris?
Is disposal of screening in compliance?
Is the unit in good condition?
Comment:
Aeration Basins Yes No NA NE
Mode of operation Ext. Air
Type of aeration system Diffused
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin’s surface?
Is the DO level acceptable?
Page#3
DocuSign Envelope ID: F4A18603-95C5-4B08-8D5C-D5D52FA84065
Permit:NC0025836
Inspection Date:07/01/2019
Owner - Facility:
Inspection Type:
Hot Springs WWTP
Compliance Evaluation
Aeration Basins Yes No NA NE
Is the DO level acceptable?(1.0 to 3.0 mg/l)
Two of the eight diffusers are not functioning. This was first noted in the 2018 inspection.
Settleability in the aeration basin was 46% in 30 minutes.
Comment:
Secondary Clarifier Yes No NA NE
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth)
The weirs should be cleaned more often, there was a lot of algae buildup on them.Comment:
Disinfection-Liquid Yes No NA NE
Is there adequate reserve supply of disinfectant?
(Sodium Hypochlorite) Is pump feed system operational?
Is bulk storage tank containment area adequate? (free of leaks/open drains)
Is the level of chlorine residual acceptable?
Is the contact chamber free of growth, or sludge buildup?
Is there chlorine residual prior to de-chlorination?
The chlorine contact chamber is very rusted and should probably be refurbished or
replaced.
Comment:
De-chlorination Yes No NA NE
Type of system ?Liquid
Is the feed ratio proportional to chlorine amount (1 to 1)?
Is storage appropriate for cylinders?
# Is de-chlorination substance stored away from chlorine containers?
Comment:
Page#4
DocuSign Envelope ID: F4A18603-95C5-4B08-8D5C-D5D52FA84065
Permit:NC0025836
Inspection Date:07/01/2019
Owner - Facility:
Inspection Type:
Hot Springs WWTP
Compliance Evaluation
De-chlorination Yes No NA NE
Are the tablets the proper size and type?
Are tablet de-chlorinators operational?
Number of tubes in use?
Comment:
Flow Measurement - Effluent Yes No NA NE
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Comment: