M. Alan Thornton, City Manager
City of Oxford
PO Box 1307
Oxford, North Carolina 27565
Dear Mr. Thornton,
Y.5U\I,�
NORTH CAROUNA
Envfrontnentol Qualify
June 28, 2019
Re: Compliance Evaluation Inspection
City of Oxford Wastewater Collection System
WQCS00086
Granville County
On June 12, 2019 Erin Deck with the Raleigh Regional Office (RRO) of the Division of Water Resources (DWR)
conducted a compliance evaluation inspection of the City of Oxford's Wastewater Collection system. The
assistance of Stevie Inscoe, Ronald Parker, Bryan Bowen, Dud Frazier, and Amy Ratliff was greatly appreciated.
Observations during the inspection are summarized below. An inspection checklist is also attached for your
records.
1. The most recently issued permit (January 01, 2015) states that The City of Oxford operates a
wastewater collection system consisting of approximately 56 miles of gravity sewer, approximately
1 I miles of force main, and 11 duplex pump stations. The current permit expires on December 31,
2022. A renewal application should be submitted at least 180 days prior to expiration.
2. The collection system is classified as a CS-2. A review of the Division's database BI.MS (Basinwide
Information Management System) lists Steve Inscoe as Operator to be in Responsible Charge (ORC).
Bryan Bowen and Ronal Parker are both listed as backup ORC-
3. Reported Sanitary Sewer Overflows (SSO), Since the last compliance inspection conducted by DWR
(June 29,2017), there have been two reportable SSOs from the collection system. The estimated
volume was less than 200 gallons, with only approximately 25 gallons reaching surface waters.
4. Records review: The Capital Improvement plan was available and consists of the required
information. The City has developed and implements and educational fats, oils and grease program
that includes at least bi-annual distribution of educational material. Adequate records are being
maintained regarding customer complaints, pump station inspections, high priority and easement
inspections. The collection system map is available on G1S. Ensure the map includes flow direction.
The following pump stations were inspected: Kingsbury, Coons Creek, Knotts Grove, Willows and
Rest area.
a. All stations have working visual and audible alarms, The audible alarm at the Willows pump
station appeared to require maintenance,
DK � A North Caro'ina Department of Environmental Quality Division of Water Resources
Raleigh Reg anal Off,.ce 3800 Barrett Drive Raleigh, North Carolina 17609
o�.mmF, .\ /'� 91c)79147no
r ,y : Jl .* r-v wti
b. The pump stations had the required signage with the required information and all fencing was
maintained. Erosion was noted around the fence post at Knotts Grove. The area should be
maintained as to ensure the fence remains intact.
c. Generators were tested. All appeared to be working at the time of the inspections.
d. Contingency plans were available at each of the pump stations.
6. The following high priority lines were inspected: Outfall line between SRI 195 and 1-85, Outfall line
near Flillandale Drive, Outfall line along SRI 195, Outfall line between Sunset to east Qualridge,
Outfall line between Maple drive and Pine street. All were rust free and appeared to be in good
condition. The right-of-ways are maintained.
7. A sewer line cleaning program is implemented with cleaning logs available for review. As of April
2019, 53,984 linear feet of sewer line have been cleaned.
You are reminded to contact this office of any situation that potentially threatens public health or the
environment. Thank you for your cooperation during this inspection. if you have any questions please contact
Erin Deck at (919) 7914200 or via email Erin.Decku ncdenr_um-
Sincerely,
Rick olich LG, Regional Assistant Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Attachment: Inspection Check list
Cc: RRO.'SWP Files
Central Files
Compliance Inspection Report
Permit: VVQCS00086 Effective: 01/01/15 Expiration: 12/31/22 Owner: City of Oxford
SOC: Effective: Expiration: Facility: Oxford Collection System
County: Granville PO Box 506
Region: Raleigh
Oxford NC 275651307
Contact Person: James R Proctor Title: Phone: 252-883-9220
Directions to Facility:
System Classifications: CS2,
Primary ORC: Stevie Vincent Inscoe
Secondary ORC(s):
Ronald Edward Parker
Bryan Coley Bowen
On -Site Representative(s):
Certification: 1003042
995013
1003770
Related Permits:
NC0025054 City of Oxford - Oxford VWVTP
Inspection Dale: 06/12/2019 Entry Time: 08 30AM
Primary Inspector. Erin M Deck',,/
Secondary Inspectors):
Phone: 919-603-1152
919-939-3226
919-603-4393
Exit Time: 02 0OPM
Phone: 919-791-4200
Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampl_ng
Permit Inspection Type: Collection system management a-ld operation
Facility Status: Compliant r7 Not Compliant
Question Areas:
Miscellaneous Que.5tons Performance Standards Operation & Maint Reqmts
Records Monitoring & Rpiing Reqmts Inspections
Pump Slaticn Manhole Lines
(See attachment summary)
Page 1 of 11
permit; VVQCS00086 Owner - Facility: Cdy of Oxford
Inspection Date: 06117J2019 Inspection Type: Collection System Inspect Non Sampling Reason for Visit.' Routine
Inspection Summary.
1. The most recently issued permit (January 01 2015) states that The City of Oxford operates a wastewater collection
system consisting of approximately 56 miles of gravity sewer. approximately 11 miles of force main, and 11 duplex pump
stations. The current permit expires on December 31. 2022. A renewal application should be submitted at least 180 days
prior to expiration.
2. The collection system is classified as a CS-2 A review of the Division's database RIMS (Basinwide Information
Management System) lists Steve Inscoe as Operator to be in Responsible Charge (ORC). Bryan Bowen and Ronal Parker
are both listed as backup ORC.
3. Reported Sanitary Sewer Overflows (SSO) Since the last compliance inspection conducted by DWR (June 29 2017)
there have been two reportable SSOs from the collection system. The estimated volume was less than 200 gallons with
only approximately 25 gallons reaching surface waters.
4. Records review The Capital Improvement plan was available and cons sts of the required information. The City has
developed and implements and educational fats, oils and grease program that includes at least bi-annual distribution of
educational material. Adequate records are being maintained regarding customer complaints pump station inspections
high priority and easement inspections. The collection system map is available on GIS. Ensure the map includes flow
dire--t-on.
5. The following pump stations were inspected: Kingsbury Coons Creek Knotts Grove, Willows and Rest area.
a. All stations have working visual and audible alarms. The audible alarm at the Willows pump station appeared to require
maintenance.
b The pump stations had the required signage with the required information and all fencing was maintained. Erosion was
noted around the fence post at Knolls Grove. The area should be maintained as to ensure the fence remains intact.
c Generators were tested. All appeared to be working at the time of the inspections.
d. Contingency plans were available at each of the pump stations.
6. The following high priority lines were inspected: Outfall line between SR1195 and 1-85 Outfall line near Hillandale Drive
Outfall line along SR1195, Outfall line between Sunset to east Qualridge. Outfall line between Maple drive and Pine street.
All were rust free and appeared to be in good condition. The right-of-ways are maintained.
7_ A sewer line cleaning program is implemented with cleaning logs available for review As of April 2019, 53 984 linear
feet of sewer line have been cleaned.
Page 2 of 11
Permit: VVOCS00098 Owner . Facility: Cny of Oxford
Inspection Date: 0611212019 Inspection Type : Collection System Inspect Non 5ampk+; Reason for Visit Routine
Performance Standards Yes No NA NE
Is Public Education Program for grease established and documented?
What educational tools are used?
flyer
Is Sewer Use Ordinancell-egal Authority available? 0 ❑ ❑
Does it appear that the Sewer Use Ordinance is enforced?
Is Grease Trap.Ordinance available?
Is Septic Tank Ordinance available (as applicable, i.e. annexation) ■ D ❑ ❑
List enforcement actions by permittee, if any. In the last 12 months
not evaluated
Has an acceptable Capital Improvement Plan {CIP) been implemented?
Does CIP address short term needs and long term 1"master plain" concepts?
Does CIP cover three to Eve year period?
❑
Does CIP include Goal Statement?
Does CIP include description of project area?
Does CIP include description of existing facilities?
Does CIP include known deficiencies?
M
Does CIP include forecasted future needs?
0❑ ❑ El
Is CIP designated only for wastewater collection and treatment?
0 D El 11
Approximate capital improvement budget for collection system?
Total annual revenue for wastewater collection and treatment?
CIP Comments
Did not mite down revenue
Is system free of known points of bypass?
0
If no, describe type of bypass and location
System is free of bypass
Is a 24-hour notification sign posted at ALL pump stations?
0 ❑ ❑ ❑
# Does the sign include
Instructions for notification?
0 D❑
Pump station ident fie0
. ❑ ❑
24-hour contact numbers
If no list deficient pump stalicns
signage was per the permit
# Do ALL pump stations have an'auto poll.ng" feature•'SCADA?
■
Number of pump stations
11
Number of pump stations that have SCADA
11
Number of pump stations that have smple telemetry
0
Page 3 of 11
Permit: WOCS00065 Owner -Facility: City of Oxford
Inspection Dale: 06/1212019 Inspection Type: Collection System Inspect Non Sampling
Reason for Visit: Routine
Number of pump stations that have only audible and visual alarms
0
Number of pump stations that do not meet permit requirements
0
# Does the permittee have a root control program?
❑ ❑ ❑
# If yes. date implemented?
Describe
d4d not evaluated
Comment; NSA
Operation & Maintenance Requirements
Yes No NA NE
Are all log books available?
M ❑ ❑ ❑
Does supervisor review all log books on a regular basis?
M ❑ ❑ ❑
Does the supeMsor have plans to address documented short-term problem areas?
M ❑ ❑ ❑
What is the schedule for reviewing inspection maintenance, & operations logs and problem areas?
Reviewed weekly
Are maintenance records for equipment available?
M ❑ 1113
Is a schedule mainta-ned for testing emergencylstandby equipment?
0 ❑ ❑ ❑
What as the schedule for testing emergencylstandby equipment?
monthly
Do pump station logs include,
Inside and outside cleaning and debris removal?
M ❑ ❑ ❑
inspecting and exercising all valves?
M ❑ ❑ ❑
Inspecting and lubricating pumps and other equipment?
0 ❑ ❑ ❑
Inspecting alarms. telemetry and auxiliary equipment?
0 ❑ ❑ ❑
Is there at least one spare pump for each pump station wfo pump rel ability?
■ ❑ ❑ ❑
Are maintenance records for right-of-ways available?
❑ ❑ ❑
Are right-of-ways currently accessible in the event of an emergency?
❑ ❑ ❑
Are system cleaning records available?
M ❑ ❑ ❑
Has at least 10% of system been cleaned annually?
0 ❑ ❑ ❑
What areas are scheduled for cleaning in the next 12 months?
Not evaluated
Is a Spill Response Action Plan available?
■ ❑ ❑ ❑
Does the plan include
24-hour contact numbers
❑ ❑ ❑
Response time
❑ ❑ ❑
Equipment list and spare parts inventory
❑ ❑ ❑
Access to cleaning equipment
M ❑ ❑ ❑
Access to construction crews. contractors. and/or eng neers
0 ❑ ❑ ❑
Source of emergency funds
M ❑ ❑ ❑
Site sanitation and cleanup materials
0 ❑ ❑ ❑
Page 4 of 11
Permit: W0050008ra Owner -Facility: City of Oxford
Inspection Date: 06/12/2019 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine
Post-overnowlspill assessment 0❑ ❑
Is a Spill Response Action Man available for all personnel? 0❑ Cl ❑
Is the spare parts inventory adequate?
Comment: NIA
Records
Yes No NA NE
Are adequate records of all SSOs spills and complaints available?
❑
Are records of SSOs that are under the reportable threshold ava table?
Do spill records indicate repeated overflows (2 or more in 12 months) at same location?
❑
If yes, is there a corrective action plan?
■ ❑
Is a map of the system available?
. ❑ ❑
Does the map include
Pipe sizes
■ ❑ ❑ ❑
Pipe materials
■ ❑ ❑
Pipe location
M ❑ ❑ ❑
Flow direction
❑
Approximate pipe age
El 111:1
Number of service taps
. 1:1 El
Pump stations and capacity
If no. what percent is complete7
List any modifications and extens.ons that need to be added to the map
flow and service taps need added
# Does the permiltee have a copy of the r permit?
Comment_ Map was missing flow and service to s
Monitoring and Reporting Requirements Yes No NA NE
Are copies of requ red press releases and distribution lists available? 0❑ ❑ ❑
Are public notices and proof of publicat.on available? 111100
# Is an annual report being prepared in accordance with G.S. 143-215AC? ❑
# Is permittee compliant with all Compliance schedules in the permits?
If no which one(s)?
did not evaluate
Comment: did not evaluate
Ins ections
Yes No NA NE
Are maintenance records fbr sewer lines available? M❑ ❑
Are records available that document pump station inspections? 0❑ ❑ ❑
Are SCADA or telemetry equipped pump stations Inspected at least once a week? 0❑ ❑ rl
Are non-SCADA/telemetry equipped pump stations inspected every day? El [] M ❑
Page 5 of 11
Permit: WOCS00086 owner -Facility: City of Oxford
Inspection Date: 06/12/2019 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine
Are records available that document citizen complaints? ❑ ❑ ❑
# Do you have a system to conduct an annual observation of entire system? 0 ❑ ❑ ❑
# Has there been an observation of remote areas in the last year? M ❑ ❑ ❑
Are records available that document inspections of high -priority lines? so ❑ ❑
Has there been visual inspections of high -priority lines in last six months? 0 ❑ 130
Comment: nla
KNOTTS GROVE - 3202 kn
Pump Station
Yes No NA N
Pump station type
Duplex
Are pump station logs available?
■ ❑ ❑ ❑
Is it accessible in all weather conditions?
M ❑ ❑ ❑
# Is general housekeeping acceptable?
0 ❑ ❑ ❑
Are all pumps present?
N ❑ ❑ ❑
Are ail pumps operable?
0 ❑ ❑ ❑
Are wet wells free of excessive debris?
0 ❑ ❑ ❑
Are upstream manholes free of excessive debris/signs of overflow?
M ❑ ❑ ❑
Are floatstcontrols for pumpstalarms operable?
0 ❑ ❑ ❑
Is "auto polling" featurelSCADA present?
0 ❑ ❑ ❑
Is "auto polling" featurelSCADA operational?
0 ❑ ❑ ❑
Is simple telemetry present?
M ❑ ❑ ❑
Is simple telemetry operational?
0 ❑ ❑ ❑
Are audio and visual alarms present?
0 ❑ ❑ ❑
Are audio and visual alarms operable?
❑ ❑ ❑
is the Pump station inspected as required?
❑ ❑ ❑
Are backflow devices in place?
❑ ❑ ❑
Are backflow devices operable?
❑ ❑ ❑
Are air relief valves in place?
M. ❑ ❑ ❑
Are air relief valves operable?
M ❑ ❑ ❑
# Is an emergency generator available?
M ❑ ❑ ❑
Can the emergency generator run the pumps?
M ❑ ❑ ❑
Is the pump station equipped for quick hook-up?
0 ❑ ❑ ❑
Is the generator operable?
0 ❑ ❑ ❑
# is fuel in tank and sufficient?
0 ❑ ❑ ❑
Is the generator inspected according to their schedule?
❑ ❑ ❑
Is a 24-hour notification sign posted?
❑ ❑ ❑
Does it include
Page 6 of 11
Permit: WoC500086 Owner - Facility: City of Oxford
Inspection Date: 0611212019 Inspection Type: Collection System Inspect Non 5ampl ng
Reason for Visit: Routine
Instructions for notification?
0❑ ❑
Pump station identifier?
■ ❑ ❑
Emergency phone number
■ ❑ ❑ El
Is public access limited?
Is pump station free of Overflow piping?
11
Is the pump station free of signs of overflow?
Are run times comparable for multiple pumps?
Comment; small amount of erosion was noted around the fence post. Discussed possible need to re air
so fence stays in tact
WILLOWS - 133 Coventry L
Pump Station
Yes No NA NE
Pump station type
Are pump station logs available?
■ ❑ ❑
Is it accessible in all weather conditions?
.
# Is general housekeeping acceptable?
Are all pumps present?
. El El 0
Are all pumps operable?
■El n
Are wet wells free of excessive debris?
Are upstream manholes free of excessive debristsigns of overflow?
E ❑ ❑ ❑
Are floats/controls for pumpslalarms operable?
0 ❑ ❑ El
Is "auto polling" fealurelSCADA present?
Is "auto polling" fealurelSCADA operational?
0
Is simple telemetry present?
0 El El 11
Is simple telemetry operational?
.
Are audio and visual alarms present?
0❑
Are audio and visual alarms operable?
❑ 11
Is the Pump station inspected as required?
❑ ❑
Are backflow devices in place?
■
Are backflow devices operable?
.
Are air relief valves In place?
0❑ ❑
Are air relief valves operable?
.
# Is an emergency generator available?
Can the emergency generator run the pumps?
0❑ ❑ ❑
Is the pump station equipped for quick hook-up?
❑
Is the generator operable?
# Is fuel in tank and sufficient?
■El El ❑
Page 7 of 11
Permit: WQCS00086 Owner-Facility;CdYof.xford
Inspection Dale: 0611212019 Inspection Type ; vollection System Inspect Non Sampil"g Reason for Visit. Pmutme
Is the generator inspected according to their schedule? M ❑ ❑ ❑
Is a 24-hour notification sign posted? ❑ ❑ ❑
Does it include
Instructions for notification? M ❑ ❑ ❑
Pump station identifier? M ❑ ❑ ❑
Emergency phone number 0 ❑ ❑ ❑
Is public access limited? M ❑ ❑ ❑
Is pump station free of overflow piping? ■ ❑ ❑ ❑
Is the pump station free of signs of overflow? M ❑ ❑ ❑
Are run times comparable for multiple pumps?
Comment: The audible alarm was working, however it sounded like it had gotten water in it. Discussed
ensuring the sneaker is working as intended.
REST AREA - 2619 bryan h
Puma Station
Yes No NA NE
Pump station type
❑"piex
Are pump station logs available?
0 ❑ ❑ ❑
Is it accessible in all weather conditions?
0 ❑ ❑ ❑
# Is general housekeeping acceptable?
❑ ❑ ❑
Are all pumps present?
❑ ❑ ❑
Are all pumps operable?
0 ❑ ❑ ❑
Are wet wells free of excessive debris?
0 ❑ ❑ ❑
Are upstream manholes free of excessive debris/signs of overflow?
■ ❑ ❑ ❑
Are floatslcontrols for pumpslalarms operable?
0 ❑ ❑ ❑
Is "auto polling" featurelSCADA present?
■ ❑ ❑ ❑
1s "auto polling" featurelSCADA operational?
0 ❑ ❑ ❑
Is simple telemetry present?
0 ❑ ❑ ❑
Is simple telemetry operational?
M ❑ ❑ ❑
Are audio and visual alarms present?
M ❑ ❑ ❑
Are audio and visual alarms operable?
M ❑ ❑ ❑
Is the Pump station inspected as required?
M ❑ ❑ ❑
Are backflow devices in place?
M ❑ ❑ ❑
Are backflow devices operable?
❑ ❑ ❑
Are air relief valves in place?
❑ ❑ ❑
Are air relief valves operable?
❑ ❑ ❑
# Is an emergency generator available?
❑ ❑ ❑
Can the emergency generator run the pumps?
❑ ❑ ❑
Page 8 of 11
Permit: WOCS00066 Owner -Facility: City of Oxford
Inspection pate: 06/1212019 Inspection Type: Collection System Inspect Wn Sam, -,ling
Reason for Visit: Raub-e
Is the pump station equipped for quick hook-up?
M❑ ❑ ❑
Is the generator operable?
. ❑
# Is fuel in tank and sufficient?
❑
Is the generator inspected accord:ng to their schedule?
M❑ ❑ ❑
Is a 24-hour notification sign posted?
M ❑ ❑ ❑
Does it include
Instruclions for notification?
0❑ ❑ 11
Pump station identifier?
0❑ El 0
Emergency phone number
0 ❑ ❑ ❑
Is public access limited?
■El ❑ 11
Is pump station free of overflow piping?
M ❑ ❑
Is the pump station free of signs of overflow?
0❑
Are run limes comparable for mull. pie pumps?
Comment.
KINGSBURY - 509 Forrest f
Pump Station
Yes No NA NE
Pump station type
oupiex
Are pump station logs available?
.
Is it accessible in all weather conditions?
# Is general housekeeping acceptable?
Are all pumps present?
■
Are all pumps operable?
0❑ El El
Are wet wells free of excessive debris?
0❑
Are upstream manholes free of excessive debris/signs of overflow?
Are floats/controls for pumpslalarms operable?
0❑
Is "auto polling" featurelSCADA present?
M 0 ❑ ❑
Is "auto polling" featurelSCADA operational?
0 ❑ ❑
Is simple telemetry present?
0 El M
Is simple telemetry operational?
■
Are audio and visual alarms present?
M El El 0
Are audio and visual alarms operable?
Is the Pump station inspected as required?
0 El El El
Are backflow devices in place?
M
Are backflow devices operable?
Are air relief valves in place?
■
Are air relief valves operable?
Page 9 of 11
Permit: WOCS00066 Owner - Facility: Ctity of Oxford
Inspection late: 06112f2019 inspection Type; Collection System Inspect Non Sampling
Reason for Visit: Routine
# Is an emergency generator available?
M ❑ ❑ ❑
Can the emergency generator run the pumps?
0 ❑ ❑ ❑
Is the pump station equipped for quick hook-up?
❑ ❑ M ❑
Is the generator operable?
M ❑ ❑ ❑
# is fuel in tank and sufficient?
❑ ❑ ❑ 0
Is the generator inspected according to their schedule?
M ❑ ❑ ❑
Is a 24-hour notification sign posted?
M ❑ ❑ ❑
Does it include:
Instructions for notification?
M ❑ ❑ ❑
Pump station identifier?
M ❑ ❑ ❑
Emergency phone number
M ❑ ❑ ❑
Is public access limited?
0 ❑ ❑ ❑
Is pump station free of overflow piping?
0 ❑ ❑ ❑
Is the pump station free of signs of overflow?
M ❑ ❑ ❑
Are run times comparable for multiple pumps?
yes
Comment:
COONS CREEK - 5521 fore
Pump Station
Yes No NA NE
Pump station type
Triplex
Are pump station logs available?
M ❑ ❑ ❑
Is it accessible in all weather conditions?
0 ❑ ❑ ❑
# Is general housekeeping acceptable?
❑ ❑ ❑
Are all pumps present?
❑ ❑ ❑
Are all pumps operable?
❑ ❑ ❑
Are wet wells free of excessive debris?
❑ ❑ ❑
Are upstream manholes free of excessive debrislsigns of overflow?
0 ❑ ❑ ❑
Are floats/controls for pumpslalarms operable?
M ❑ ❑ ❑
Is "auto polling" featurelSCADA present?
M ❑ ❑ ❑
Is "auto polling" featurelSCADA operational?
0 ❑ ❑ ❑
Is simple telemetry present?
❑ ❑ 0 ❑
Is simple telemetry operational?
❑ ❑ 0 ❑
Are audio and visual alarms present?
0 ❑ ❑ ❑
Are audio and visual alarms operable?
M ❑ ❑ ❑
Is the Pump station inspected as required?
0 ❑ ❑ ❑
Are backflow devices in place?
❑ ❑ ❑ 0
Are backflow devices operable?
❑ ❑ ❑ o
Page 10 of 11
Permit: WOCSO0086 Owner - Facility: City of Oxford
Inspection Date: 06112t2019 Inspection Type : Collection System Inspect (Jon Sampling Reason for Visit: Routine
Are air relief valves in place? 0
Are air relief valves operable?
# Is an emergency generator available? 0❑ ❑ ❑
Can the emergency generator run the pumps? 0 ❑
Is the pump station equipped for quick hook-up7 ❑ ❑ 0 ❑
Is the generator operable? ■
# Is fuel in tank and sufficient?
Is the generator inspected according to their schedule? M
El El El
Is a 24-hour notification sign posted? M❑ ❑ ❑
Does it include.
Instructions for notification? ■
Pump station identifier? ■ ❑ ❑ ❑
Emergency (shone number ❑
Is public access limited? ❑
Is pump station free of overflow piping?
Is the pump station free of signs of overflow? M El El 11
Are run times comparable for multiple pumps? yes
Comment: largest pump station- has a back up generator
Page 11 of 11