HomeMy WebLinkAbout20190875 Ver 1_Water Set_20190628HAYWOOD CROSSING SUBDIVISION WATER PLAN SPANO & ASSOCIATES HENDERSON OWNER/DEVELOPER CONTACT: NAME: MR. RALPH SPANO COMPANY: SPANO & ASSOCIATES HAYWOOD, LLC ADDRESS: 1540 INTERNATIONAL PKWY #200, LAKE MARY, FL 32746 PHONE: 407-574-4060 EMAIL: SPAN01688@GMAIL.COM ENGINEER/EROSION CONTROL CONTACT: NAME: SCOTT BURWELL, P.E. COMPANY: MCGILL ASSOCIATES, P.A. ADDRESS: 55 BROAD STREET, ASHEVILLE, NC 28801 PHONE: 828-252-0575 EMAIL: SCOTT.BURWELL@MCGILLASSOCIATES.COM PROJECT NOTES: TOTAL AREA TO BE SUBDIVIDED: 20.38 AC AVERAGE PROPOSED LOT SIZE: 0.78 AC (33,761 SF) TOTAL NUMBER OF PROPOSED LOTS: 20 McGill 0- A S S O C I A T E S ENGINEERING -PLANNING -FINANCE 55 BROAD STREET ASHEVILLE, NC 28801 PH. (828) 252-0575 FIRM LICENSE # C-0459 COUNTY, N PROJECT SITE X10 HAYWOOD RD HAYWOOD KNOLLS DRIVE t�z FOR REVIEW ONLY JUNE 2019 HAYWOOD, NORTH CAROLINA SCHEDULE OF DRAWINGS G-001 ..... COVER SHEET G-002 ..... GENERAL NOTES AND LEGEND G-004 ..... UTILITY NOTES CD -101 ..... EXISTING CONDITIONS C-101 ..... MASTER PLAN C-110 ..... OVERALL WATER PLAN C-111 ..... PLAN PROFILE - WATER LINE A C-112 ..... PLAN PROFILE - WATER LINE B C-508 ..... MISCELLANEOUS DETAILS C-509 ..... MISCELLANEOUS DETAILS C-511 ..... MISCELLANEOUS DETAILS NOT INCLUDED WITH THIS SUBMITTAL NOT INCLUDED WITH - . . . . THIS SUBMITTAL Know what's below. CaII before you dig. N.C. One -Call Center )ial 811 or 1-800-632-4949 GENERAL CONSTRUCTION NOTES 1. UNLESS OTHERWISE STATED, ALL FILL AREAS SHALL BE CONSTRUCTED IN LAYERS OF 8" MAXIMUM THICKNESS, WITH WATER ADDED OR SOIL CONDITIONED TO THE OPTIMUM MOISTURE CONTENT AS DETERMINED BY THE ENGINEER AND COMPACTED WITH A SHEEP'S FOOT ROLLER TO A COMPACTION EQUAL TO OR GREATER THAN 95% (100% IN THE TOP 2' OF THE SUB GRADE BELOW ROADWAYS AND PARKING LOTS) OF THE DENSITY OBTAINED BY COMPACTING A SAMPLE OF THE MATERIAL IN ACCORDANCE WITH THE STANDARD PROCTOR METHOD OF MOISTURE -DENSITY RELATIONSHIP TEST, ASTM D698 OR AASHTO-99 UNLESS SPECIFIED IN OTHER SPECIFICATIONS. 2. ENTIRE AREA TO BE GRADED SHALL BE CLEARED AND GRUBBED. NO FILL SHALL BE PLACED ON ANY AREA NOT CLEARED AND GRUBBED. 3. ALL SOIL EROSION CONTROL MEASURES REQUIRED BY THE GRADING PLAN SHALL BE PERFORMED PRIOR TO GRADING, CLEARING OR GRUBBING. ALL EROSION CONTROL DEVICES SUCH AS SILT FENCES, ETC., SHALL BE MAINTAINED IN WORKABLE CONDITION FOR THE LIFE OF THE PROJECT AND SHALL BE REMOVED AT THE COMPLETION OF THE PROJECT ONLY ON THE ENGINEER'S APPROVAL. PAYMENT SHALL BE CONSIDERED INCIDENTAL TO CLEARING AND GRUBBING. IF DURING THE LIFE OF THE PROJECT, A STORM CAUSES SOIL EROSION WHICH CHANGES FINISH GRADES OR CREATES "GULLIES" AND "WASHED AREAS", THESE SHALL BE REPAIRED AT NO EXTRA COST, AND ALL SILT WASHED OFF OF THE PROJECT SITE ONTO ADJACENT PROPERTY SHALL BE REMOVED AS DIRECTED BY THE ENGINEER AT NO EXTRA COST. THE CONTRACTOR SHALL ADHERE TO ANY APPROVED EROSION CONTROL PLANS WHETHER INDICATED IN THE CONSTRUCTION PLANS OR UNDER SEPARATE COVER. 4. DISPOSABLE MATERIAL A. CLEARING AND GRUBBING WASTES SHALL BE REMOVED FROM THE SITE AND PROPERLY DISPOSED OF BY THE CONTRACTOR AT HIS EXPENSE, UNLESS SPECIFIED OTHERWISE. TOPSOIL MAY BE PLACED UP TO 6" IN DEPTH ON SLOPES AND OPEN AREAS IF AVAILABLE WITH PRIOR APPROVAL BY ENGINEER. B. SOLID WASTES TO BE REMOVED SUCH AS SIDEWALKS CURBS PAVEMENT ETC., MAY BE PLACED IN SPECIFIC DISPOSAL AREAS DELINEATED ON THE PLANS OR REMOVED FROM THE SITE AS REQUIRED BY THE SPECIFICATIONS. THIS MATERIAL SHALL HAVE A MINIMUM COVER OF 2'. THE CONTRACTOR SHALL MAINTAIN SPECIFIED COMPACTION REQUIREMENTS IN THESE AREAS. WHEN DISPOSAL SITES ARE NOT PROVIDED, THE CONTRACTOR SHALL REMOVE THIS WASTE FROM THE SITE AND PROPERLY DISPOSE OF IT AT HIS EXPENSE. C. ABANDONED UTILITIES SUCH AS CULVERTS, WATER PIPE, HYDRANTS, CASTINGS, PIPE APPURTENANCES, UTILITY POLES, ETC., SHALL BE THE PROPERTY OF THE SPECIFIC UTILITY AGENCY, OR COMPANY HAVING JURISDICTION. BEFORE THE CONTRACTOR CAN REMOVE, DESTROY, SALVAGE, REUSE, SELL OR STORE FOR HIS OWN USE ANY ABANDONED UTILITY, HE MUST PRESENT TO THE OWNER WRITTEN PERMISSION FROM THE UTILITY INVOLVED. D. ON SITE BURNING IS PROHIBITED. 5. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ADJUSTMENT OF ALL UTILITY SURFACE ACCESSES WHETHER HE PERFORMS THE WORK OR A UTILITY COMPANY PERFORMS THE WORK. 6. THE CONTRACTOR SHALL CONTROL ALL "DUST" BY PERIODIC WATERING AND SHALL PROVIDE ACCESS AT ALL TIMES FOR PROPERTY OWNERS WITHIN THE PROJECT AREA AND FOR EMERGENCY VEHICLES. ALL OPEN DITCHES AND HAZARDOUS AREAS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH THE SPECIFICATIONS. 7. ALL AREAS WHERE THERE IS EXPOSED DIRT SHALL BE SEEDED, FERTILIZED AND MULCHED ACCORDING TO THE SPECIFICATIONS. THE FINISHED SURFACE SHALL BE TO GRADE AND SMOOTH, FREE OF ALL ROCKS LARGER THAN 3", EQUIPMENT TRACKS, DIRT CLODS, BUMPS, RIDGES AND GOUGES PRIOR TO SEEDING; THE SURFACE SHALL BE LOOSENED TO A DEPTH OF t4"-6" TO ACCEPT SEED. THE CONTRACTOR SHALL NOT PROCEED WITH SEEDING OPERATIONS WITHOUT FIRST OBTAINING THE ENGINEER'S APPROVAL OF THE GRADED SURFACE. ALL SEEDING SHALL BE PERFORMED BY A MECHANICAL "HYDRO -SEEDER". HAND SEEDING SHALL BE AUTHORIZED ON AN AREA BY AREA APPROVAL BY THE ENGINEER. DISTURBED AREAS SHOULD THEN BE MATTED WITH SHORT-TERM PHOTODEGRADABLE EROSION CONTROL MATTING. 8. WHERE SPECIFIED, STORM DRAIN PIPE SHALL BE REINFORCED CONCRETE PIPE (RCP) CONFORMING TO AASHTO M-170, AS CONTAINED IN NCDOT STANDARD SPECIFICATION 1032-9 FOR WALL TYPE. WHERE SPECIFIED, ALL STORM DRAIN PIPE SHALL BE HIGH DENSITY POLYETHYLENE (HDPE). SMOOTH WALL INTERIOR, WITH WATER TIGHT JOINTS, BACKFILLED WITH # 57 WASHED STONE UP TO MIN. 6" OVER THE TOP OF THE PIPE. HDPE PIPE USED FOR STORM DRAINAGE DETENTION SYSTEMS SHALL BE ADS N12 WT OR APPROVED EQUAL. 9. CONTRACTOR SHALL VERIFY ALL ELEVATIONS BEFORE INSTALLATION OF FACILITIES. 10. CATCH BASINS CAST -IN-PLACE SHALL CONFORM TO THE REQUIREMENTS OF NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES (LATEST EDITION) ARTICLES 840-1 THROUGH 840-3. CURB INLET CATCH BASIN SHALL CONFORM TO NCDOT STANDARD DETAILS 840.02 THROUGH 840.04. DROP INLETS SHALL CONFORM TO STANDARD DETAIL 840.14. JUNCTION BOXES SHALL CONFORM TO STANDARD DETAIL 840.31. 11. CURB INLET FRAME, GRATE AND HOOD SHALL BE NEENAH R -3233D, PRODUCTS BY DEWEY BROS., U.S. FOUNDRY OR EQUAL. DROP INLET FRAME AND GRATE SHALL BE NEENAH R -3339A OR EQUAL. FIELD INLET COVER SHALL CONFORM TO NCDOT STANDARD DETAIL 840.04, OPENING FACING UPSTREAM. 12. CONCRETE AND MASONRY SHALL MEET THE REQUIREMENTS OF APPROPRIATE SECTION OF NCDOT STANDARD SPECIFICATIONS FOR ROAD AND STRUCTURES (LATEST EDITION). CONCRETE SHALL BE CLASS A OR B, 4000 PSI MINIMUM, MEETING THE REQUIREMENTS OF SECTION 1000, CONSTRUCTED IN ACCORDANCE WITH SECTION 825. MASONRY SHALL MEET THE REQUIREMENTS OF SECTION 1040, CONSTRUCTED IN ACCORDANCE WITH SECTION 830 AND/OR 834. 13. TOPS OF PROPOSED FRAMES AND GRATES SHALL BE FLUSH WITH FINISHED GRADE. 14 NO BASE COURSE SHALL BE PLACED ON MUCK, PIPE, CLAY, ORGANIC MATTER, OR OTHER UNSUITABLE MATTER, AND A MINIMUM COMPACTION RATE OF SUBGRADE PRIOR TO PAVING SHALL NOT BE LESS THAN 95% BY STANDARD PROCTOR METHOD AND CERTIFIED BY A PROFESSIONAL ENGINEER. 15. ALL RETAINING WALLS SHOWN WILL BE DESIGNED BY A LICENSED NORTH CAROLINA PROFESSIONAL ENGINEER PRIOR TO PERMITTING AND CONSTRUCTION OF THE WALL. NOTES: STATEMENT OF PERMIT AND CONTRACTOR RESPONSIBILITIES 1. PROJECT SITE CONTAINS JURISDICTIOANL WATERS OF THE U.S (WOTUS). 2. PROJECT INVOLVES IMPACTS TO WOTUS IN SEVERAL LOCATIONS. 3. PROPOSED IMPACTS TO WOTUS ARE REGULATED BY THE CLEAN WATER ACT SECTIONS 404 AND 401. 4. PERMITS HAVE BEEN OBTAINED BY THE CITY OF XXX INC TO AUTHORIZE THE PROPOSED IMPACTS TO WOTUS AND ARE SUBJECT TO THE TERMS AND CONDITIONS OF THE PERMITS. 5. CWA 404/401 PERMIT REQUIREMENTS, TERMS, AND CONDITIONS ARE SUMMARIZED ON THIS SHEET ALONG WITH VARIOUS ASSOCIATED DETAILS AND SPECIFICATIONS. 6. A COPY OF THE PERMITS HAVE BEEN PROVIDED TO THE CONTRACTOR AT THE PRE -CONSTRUCTION MEETING. THE CONTRACTOR IS RESPONSIBLE FOR READING THE PERMITS, PLANS AND SPECIFICATIONS, AND UNDERSTANDING HIS/HER RESPONSIBILITIES UNDER THE PERMITS, WHICH INCLUDE BUT ARE NOT LIMITED TO: A) COMPLIANCE WITH ALL PERMIT CONDITIONS RELATING TO CONTRACTED CONSTRUCTION ACTIVITIES BOTH ON-SITE AND OFF-SITE, IF OFF-SITE AREAS ARE USED FOR PROJECT RELATED PURPOSES (EG: ACCESS, LAYDOWN, STAGING, BORROW, WASTE, ETC.) B) COMMUNICATION OF PERMIT COMPLIANCE RESPONSIBILITIES TO SUBCONTRACTORS WORKING ON THE PROJECT. C) COORDINATION WITH PROJECT ENGINEER REGARDING PERMIT COMPLIANCE RELATED ISSUES AND QUESTIONS. D) IMMEDIATE REPORTING TO PROJECT ENGINEER OR OWNER OF ANY VIOLATION OR SUSPECTED VIOLATION OF PERMIT CONDITIONS. E) A COPY OF ALL PERMITS AND CONDITIONS SHOULD BE MADE AVAILABLE AT THE PROJECT SITE DURING CONSTRUCTION AND MAINTENANCE ACTIVITIES. Know what's below. 0111 before you dig. N.C. One -Call Center )ial 811 or 1-800-632-4949 NATIONWIDE PERMIT CONDITIONS 1. AQUATIC LIFE MOVEMENTS - NO ACTIVITY MAY SUBSTANTIALLY DISRUPT THE NECESSARY LIFE CYCLE MOVEMENTS OF THOSE SPECIES OF AQUATIC LIFE INDIGENOUS TO THE WATERBODY, INCLUDING THOSE SPECIES THAT NORMALLY MIGRATE THROUGH THE AREA UNLESS THE ACTIVITY'S PRIMARY PURPOSE IS TO IMPOUND WATER. ALL PERMANENT AND TEMPORARY CROSSINGS OF WATERBODIES SHALL BE SUITABLY CULVERTED, BRIDGED, OR OTHERWISE DESIGNED AND CONSTRUCTED TO MAINTAIN LOW FLOWS TO SUSTAIN THE MOVEMENT OF THOSE AQUATIC SPECIES. 2. SUITABLE MATERIAL - NO ACTIVITY MAY USE UNSUITABLE MATERIAL (E.G., TRASH, DEBRIS, CAR BODIES, ASPHALT, ETC.). MATERIAL USED FOR CONSTRUCTION OR DISCHARGED MUST BE FREE FROM TOXIC POLLUTANTS IN TOXIC AMOUNTS (SEE SECTION 307 OF THE CLEAN WATER ACT). 3. MANAGEMENT OF WATER FLOWS - TO THE MAXIMUM EXTENT PRACTICABLE, THE PRE -CONSTRUCTION COURSE, CONDITION, CAPACITY, AND LOCATION OF OPEN WATERS MUST BE MAINTAINED FOR EACH ACTIVITY, INCLUDING STREAM CHANNELIZATION AND STORM WATER MANAGEMENT ACTIVITIES, EXCEPT AS PROVIDED BELOW. THE ACTIVITY MUST BE CONSTRUCTED TO WITHSTAND EXPECTED HIGH FLOWS. THE ACTIVITY MUST NOT RESTRICT OR IMPEDE THE PASSAGE OF NORMAL OR HIGH FLOWS, UNLESS THE PRIMARY PURPOSE OF THE ACTIVITY IS TO IMPOUND WATER OR MANAGE HIGH FLOWS. THE ACTIVITY MAY ALTER THE PRE -CONSTRUCTION COURSE, CONDITION, CAPACITY, AND LOCATION OF OPEN WATERS IF IT BENEFITS THE AQUATIC ENVIRONMENT (E.G., STREAM RESTORATION OR RELOCATION ACTIVITIES). 4. EQUIPMENT - HEAVY EQUIPMENT WORKING IN WETLANDS OR MUDFLATS MUST BE PLACED ON MATS, OR OTHER MEASURES MUST BE TAKEN TO MINIMIZE SOIL DISTURBANCE. 5. SOIL EROSION AND SEDIMENT CONTROLS - APPROPRIATE SOIL EROSION AND SEDIMENT CONTROLS MUST BE USED AND MAINTAINED IN EFFECTIVE OPERATING CONDITION DURING CONSTRUCTION, AND ALL EXPOSED SOIL AND OTHER FILLS, AS WELL AS ANY WORK BELOW THE ORDINARY HIGH WATER MARK OR HIGH TIDE LINE, MUST BE PERMANENTLY STABILIZED AT THE EARLIEST PRACTICABLE DATE. PERMITTEES ARE ENCOURAGED TO PERFORM WORK WITHIN WATERS OF THE UNITED STATES DURING PERIODS OF LOW -FLOW OR NO -FLOW. 6. REMOVAL OF TEMPORARY FILLS - TEMPORARY FILLS MUST BE REMOVED IN THEIR ENTIRETY AND THE AFFECTED AREAS RETURNED TO PRE -CONSTRUCTION ELEVATIONS. THE AFFECTED AREAS MUST BE REVEGETATED, AS APPROPRIATE. 7. PROPER MAINTENANCE - ANY AUTHORIZED STRUCTURE OR FILL SHALL BE PROPERLY MAINTAINED, INCLUDING MAINTENANCE TO ENSURE PUBLIC SAFETY AND COMPLIANCE WITH APPLICABLE NWP GENERAL CONDITIONS, AS WELL AS ANY ACTIVITY -SPECIFIC CONDITIONS ADDED BY THE DISTRICT ENGINEER TO AN NWP AUTHORIZATION. 8. DISCOVERY OF PREVIOUSLY UNKNOWN REMAINS AND ARTIFACTS - IF YOU DISCOVER ANY PREVIOUSLY UNKNOWN HISTORIC, CULTURAL OR ARCHEOLOGICAL REMAINS AND ARTIFACTS WHILE ACCOMPLISHING THE ACTIVITY AUTHORIZED BY THIS PERMIT, YOU MUST IMMEDIATELY NOTIFY THE DISTRICT ENGINEER OF WHAT YOU HAVE FOUND, AND TO THE MAXIMUM EXTENT PRACTICABLE, AVOID CONSTRUCTION ACTIVITIES THAT MAY AFFECT THE REMAINS AND ARTIFACTS UNTIL THE REQUIRED COORDINATION HAS BEEN COMPLETED. THE DISTRICT ENGINEER WILL INITIATE THE FEDERAL, TRIBAL AND STATE COORDINATION REQUIRED TO DETERMINE IF THE ITEMS OR REMAINS WARRANT A RECOVERY EFFORT OR IF THE SITE IS ELIGIBLE FOR LISTING IN THE NATIONAL REGISTER OF HISTORIC PLACES. 9. RESTRICTION ON USE OF LIVE CONCRETE - FOR ALL NWPS WHICH ALLOW THE USE OF CONCRETE AS A BUILDING MATERIAL, LIVE OR FRESH CONCRETE, INCLUDING BAGS OF UNCURED CONCRETE, MAY NOT COME INTO CONTACT WITH THE WATER IN OR ENTERING INTO WATERS OF THE US. WATER INSIDE COFFER DAMS OR CASINGS THAT HAS BEEN IN CONTACT WITH WET CONCRETE SHALL ONLY BE RETURNED TO WATERS OF THE US WHEN IT IS NO LONGER POSES A THREAT TO AQUATIC ORGANISMS. 10. REQUIREMENTS FOR USING RIPRAP FOR BANK STABILIZATION - FOR ALL NWPS THAT ALLOW FOR THE USE OF RIPRAP MATERIAL FOR BANK STABILIZATION, THE FOLLOWING MEASURES SHALL BE APPLIED: 10.1. FILTER CLOTH MUST BE PLACED UNDERNEATH THE RIPRAP AS AN ADDITIONAL REQUIREMENT OF ITS USE IN NORTH CAROLINA WATERS. 10.2. THE PLACEMENT OF RIPRAP SHALL BE LIMITED TO THE AREAS DEPICTED ON SUBMITTED WORK PLAN DRAWINGS. 10.3. THE RIPRAP MATERIAL SHALL BE CLEAN AND FREE FROM LOOSE DIRT OR ANY POLLUTANT EXCEPT IN TRACE QUANTITIES THAT WOULD NOT HAVE AN ADVERSE ENVIRONMENTAL EFFECT. 10.4. IT SHALL BE OF A SIZE SUFFICIENT TO PREVENT ITS MOVEMENT FROM THE AUTHORIZED ALIGNMENT BY NATURAL FORCES UNDER NORMAL CONDITIONS. 10.5. THE RIPRAP MATERIAL SHALL CONSIST OF CLEAN ROCK OR MASONRY MATERIAL SUCH AS, BUT NOT LIMITED TO, GRANITE, MARL, OR BROKEN CONCRETE. 11. SAFE PASSAGE REQUIREMENTS FOR CULVERT PLACEMENT - FOR ALL NWPS THAT INVOLVE THE CONSTRUCTION/INSTALLATION OF CULVERTS, MEASURES WILL BE INCLUDED IN THE CONSTRUCTION/INSTALLATION THAT WILL PROMOTE THE SAFE PASSAGE OF FISH AND OTHER AQUATIC ORGANISMS. THE DIMENSION, PATTERN, AND PROFILE OF THE STREAM ABOVE AND BELOW A PIPE OR CULVERT SHOULD NOT BE MODIFIED BY WIDENING THE STREAM CHANNEL OR BY REDUCING THE DEPTH OF THE STREAM IN CONNECTION WITH THE CONSTRUCTION ACTIVITY. THE WIDTH, HEIGHT, AND GRADIENT OF A PROPOSED CULVERT SHOULD BE SUCH AS TO PASS THE AVERAGE HISTORICAL LOW FLOW AND SPRING FLOW WITHOUT ADVERSELY ALTERING FLOW VELOCITY. SPRING FLOW SHOULD BE DETERMINED FROM GAGE DATA, IF AVAILABLE. IN THE ABSENCE OF SUCH DATA, BANKFULL FLOW CAN BE USED AS A COMPARABLE LEVEL. EXISTING CONDITIONS LEGEND NCDEQ GENERAL CONSTRUCTION CONDITIONS 1. THE CONTRACTOR SHALL MINIMIZE CLEARING WITHIN WETLANDS AND ACROSS STREAMS TO THE GREATEST EXTENT PRACTICABLE AND SHALL NOT EXCEED 50' WIDE FOR GAS UTILITY LINES AND 40' WIDE FOR ALL OTHER UTILITY LINES. EXCEPTIONS TO THIS CONDITION WILL REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. FOR CONSTRUCTION CORRIDORS IN WETLANDS AND ACROSS STREAM CHANNELS, STUMPS SHALL BE GRUBBED ONLY AS NEEDED TO INSTALL THE UTILITY AND REMAINING STUMPS SHALL BE CUT OFF AT GRADE LEVEL. THE GENERAL STRIPPING OF TOPSOIL WITHIN WETLANDS ALONG THE CONSTRUCTION CORRIDOR IS NOT PERMITTED. 2. PERMANENT MAINTAINED ACCESS CORRIDORS IN WETLANDS AND ACROSS STREAM CHANNELS SHALL BE RESTRICTED TO THE MINIMUM WIDTH PRACTICABLE AND SHALL NOT EXCEED 30' WIDE FOR GAS UTILITY LINES AND 20' WIDE FOR ALL OTHER UTILITY LINES EXCEPT AT MANHOLE LOCATIONS. 15' X 15' PERPENDICULAR VEHICLE TURN-AROUNDS ARE ALLOWED IN ACCESS CORRIDORS BUT MUST BE SPACED AT LEAST 500' APART. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 3. THE CONTRACTOR SHALL HAVE A SPECIFIC PLAN FOR RESTORING WETLAND CONTOURS. ANY EXCESS MATERIAL SHALL BE REMOVED TO A HIGH GROUND DISPOSAL AREA. THE MIXING OF TOPSOIL AND SUBSOILS WITHIN WETLANDS ALONG UTILITY CORRIDORS SHALL BE MINIMIZED TO THE GREATEST EXTENT PRACTICABLE DURING EXCAVATION. THE SOILS SHALL BE PLACED ON FABRIC TO MINIMIZE IMPACTS WHENEVER POSSIBLE. TOPSOIL EXCAVATED FROM UTILITY TRENCHES SHALL BE PILED SEPARATELY FROM SUBSOILS AND BACKFILLED INTO THE TRENCH ONLY AFTER THE SUBSOILS HAVE BEEN PLACED AND COMPACTED. 4. NO WASTE, SPOIL, SOLIDS, OR FILL OF ANY KIND CAN OCCUR IN WETLANDS OR WATERS BEYOND THE FOOTPRINT OF THE IMPACT AREA (INCLUDING TEMPORARY IMPACTS) OR BEYOND THE PERMITTED THRESHOLDS WITHOUT WRITTEN AUTHORIZATION FROM THE PROJECT ENGINEER. NO REMOVAL OF VEGETATION OR OTHER IMPACTS OF ANY KIND CAN OCCUR TO STATE REGULATED RIPARIAN BUFFERS BEYOND THE FOOTPRINT OF IMPACTS APPROVED IN A BUFFER AUTHORIZATION OR VARIANCE OR AS LISTED AS AN EXEMPT ACTIVITY IN THE APPLICABLE RIPARIAN BUFFER RULES. 5. ALL EROSION CONTROL DEVICES SHALL BE MAINTAINED ON ALL CONSTRUCTION SITES, BORROW SITES, AND WASTE PILE (SPOIL) SITES, INCLUDING CONTRACTOR OWNED OR LEASED BORROW PITS ASSOCIATED WITH THE PROJECT. SUFFICIENT MATERIALS REQUIRED FOR STABILIZATION AND/OR REPAIR OF EROSION CONTROL MEASURES AND STORMWATER ROUTING AND TREATMENT SHALL BE ON-SITE AT ALL TIMES. 6. SEDIMENT AND EROSION CONTROL MEASURES SHALL NOT BE PLACED IN WETLANDS OR WATERS EXCEPT WITHIN THE FOOTPRINT OF TEMPORARY OR PERMANENT IMPACTS AUTHORIZED UNDER THE PERMITS. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 7. EROSION CONTROL MATTING THAT INCORPORATES PLASTIC MESH AND/OR PLASTIC TWINE SHALL NOT BE USED ALONG STREAMBANKS OR WITHIN WETLANDS. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 8. AN NPDES CONSTRUCTION STORMWATER PERMIT (NCGO10000) IS REQUIRED FOR CONSTRUCTION PROJECTS THAT DISTURB ONE OR MORE ACRES OF LAND. THE NCGO10000 PERMIT ALLOWS STORMWATER TO BE DISCHARGED DURING LAND DISTURBING CONSTRUCTION ACTIVITIES AS STIPULATED IN THE CONDITIONS OF THE PERMIT. IF THE PROJECT IS COVERED BY THE PERMITS, FULL COMPLIANCE WITH PERMIT CONDITIONS INCLUDING THE EROSION AND SEDIMENTATION CONTROL PLAN, INSPECTIONS AND MAINTENANCE, SELF-MONITORING, RECORD KEEPING AND REPORTING REQUIREMENTS IS REQUIRED. 9. ALL WORK IN OR ADJACENT TO STREAMS SHALL BE CONDUCTED SO THAT THE FLOWING STREAM DOES NOT COME IN CONTACT WITH THE DISTURBED AREA. APPROVED BEST MANAGEMENT PRACTICES FROM THE MOST CURRENT VERSION OF THE INC SEDIMENT AND EROSION CONTROL MANUAL, OR THE NC DOT CONSTRUCTION AND MAINTENANCE ACTIVITIES MANUAL, SUCH AS SANDBAGS, ROCK BERMS, COFFERDAMS, AND OTHER DIVERSION STRUCTURES SHALL BE USED TO MINIMIZE EXCAVATION IN FLOWING WATER. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 10. CULVERTS SHALL BE INSTALLED IN SUCH A MANNER THAT THE ORIGINAL STREAM PROFILES ARE NOT ALTERED AND ALLOW FOR AQUATIC LIFE MOVEMENT DURING LOW FLOWS. THE DIMENSION PATTERN AND PROFILE OF THE STREAM ABOVE AND BELOW A PIPE OR CULVERT SHALL NOT BE MODIFIED BY WIDENING THE STREAM CHANNEL OR BY REDUCING THE DEPTH OF THE STREAM IN CONNECTION WITH THE CONSTRUCTION ACTIVITY. 11. APPLICATION OF FERTILIZER TO ESTABLISH PLANTED/SEEDED VEGETATION WITHIN DISTURBED RIPARIAN AREAS SHALL COMPLY WITH ALL OTHER FEDERAL, STATE AND LOCAL REGULATIONS. FERTILIZER APPLICATION SHALL BE ACCOMPLISHED IN A MANNER THAT MINIMIZES THE RISK OF CONTACT BETWEEN THE FERTILIZER AND SURFACE WATERS. 12. IF CONCRETE IS USED DURING CONSTRUCTION, THEN ALL NECESSARY MEASURES SHALL BE TAKEN TO PREVENT DIRECT CONTACT BETWEEN UNCURED OR CURING CONCRETE AND WATERS OF THE US. WATER THAT INADVERTENTLY CONTACTS UNCURED CONCRETE SHALL NOT BE DISCHARGED TO WATERS OF THE US. 13. ALL PROPOSED AND APPROVED TEMPORARY FILL AND CULVERTS SHALL BE REMOVED AND THE IMPACTED AREA RETURNED TO NATURAL CONDITIONS WITHIN 60 CALENDAR DAYS AFTER THE TEMPORARY IMPACT IS NO LONGER NECESSARY. THE IMPACTED AREAS SHALL BE RETURNED TO ORIGINAL GRADE, INCLUDING EACH STREAM'S ORIGINAL CROSS SECTIONAL DIMENSIONS, PLANFORM PATTERN, AND LONGITUDINAL BED PROFILE. ALL TEMPORARY IMPACTS SHALL BE RESTORED AND STABILIZED WITH NATIVE VEGETATION. 14. ALL PROPOSED AND APPROVED TEMPORARY PIPES/CULVERTS/RIP-RAP PADS ETC. IN STREAMS SHALL BE INSTALLED AS OUTLINED IN THE MOST RECENT EDITION OF THE NC SEDIMENT AND EROSION CONTROL PLANNING AND DESIGN MANUAL OR THE NCDOT BEST MANAGEMENT PRACTICES FOR CONSTRUCTION AND MAINTENANCE ACTIVITIES SO AS NOT TO RESTRICT STREAM FLOW OR CAUSE DIS -EQUILIBRIUM DURING USE OF THIS CERTIFICATION. 15. ANY RIP -RAP REQUIRED FOR PROPER CULVERT PLACEMENT, STREAM STABILIZATION, OR RESTORATION OF TEMPORARILY DISTURBED AREAS SHALL BE RESTRICTED TO THE AREA DIRECTLY IMPACTED BY THE APPROVED CONSTRUCTION ACTIVITY. ALL RIP -RAP SHALL BE PLACED SUCH THAT THE ORIGINAL STREAM ELEVATION AND STREAM BANK CONTOURS ARE RESTORED AND MAINTAINED, NOT RESULT IN THE DE -STABILIZATION OF STREAM BED OR BANKS UPSTREAM OR DOWNSTREAM OF THE AREA, AND NOT RESTRICT AQUATIC LIFE PASSAGE. 16. ANY RIP -RAP USED FOR STREAM OR SHORELINE STABILIZATION SHALL BE OF SIZE AND DENSITY TO PREVENT MOVEMENT BY WAVE, CURRENT, OR STREAM FLOWS, AND WILL CONSIST OF CLEAN ROCK OR MASONRY MATERIAL. RIP -RAP SHALL NOT BE INSTALLED IN THE STREAMBED EXCEPT IN SPECIFIC AREAS REQUIRED FOR VELOCITY CONTROL AND TO ENSURE STRUCTURAL INTEGRITY OF BANK STABILIZATION MEASURES. 17. ALL MECHANIZED EQUIPMENT OPERATED NEAR SURFACE WATERS SHALL BE INSPECTED, FUELED, LUBRICATED, AND MAINTAINED REGULARLY AND MAINTENANCE PERFORMED IN A MANNER TO PREVENT CONTAMINATION OF STREAM WATER FROM FUELS, LUBRICANTS, HYDRAULIC FLUIDS, OR OTHER TOXIC MATERIALS. 18. HEAVY EQUIPMENT WORKING IN WETLANDS SHALL BE PLACED ON MATS OR OTHER MEASURES TAKEN TO MINIMIZE SOIL DISTURBANCE. 19. THE CONTRACTOR OR OTHER RESPONSIBLE ENTITY SHALL REPORT ANY PETROLEUM SPILL OF 25 GALLONS OR MORE; ANY SPILL REGARDLESS OF AMOUNT THAT CAUSES A SHEEN ON SURFACE WATERS; ANY PETROLEUM SPILL REGARDLESS OF SIZE THAT OCCURS WITHIN 100 -FEET OF SURFACE WATER; AND ANY PETROLEUM SPILL LESS THAN 25 GALLONS THAT CANNOT BE CLEANED UP WITHIN 24 HOURS. -o-o-o-o-o-o-o-o-o-o-o-o-o-o- TEL PED TELEPHONE PEDESTAL 12. IN THE TWENTY(20)COUNTIES OF NORTH CAROLINA DESIGNATED AS COASTAL COUNTIES BY THE �ELEC PED ELECTRIC PEDESTAL COASTAL AREA MANAGEMENT ACT (CAMA): ALL PIPES/CULVERTS MUST BE SUFFICIENTLY SIZED TO CATV CABLE TV PEDESTAL ALLOW FOR THE BURIAL OF THE BOTTOM OF THE PIPE/CULVERT AT LEAST ONE FOOT BELOW PED RIGHT OF WAY NORMAL BED ELEVATION WHEN THEY ARE PLACED WITHIN THE PUBLIC TRUST AREA OF SIGN SIGN ENVIRONMENTAL CONCERN (AEC) AND/OR THE ESTUARINE WATERS AEC AS DESIGNATED BY CAMA, CATV UNDERGROUND CABLE TV SIGN AND/OR ALL STREAMS APPEARING AS BLUE LINES ON UNITED STATES GEOLOGICAL SURVEY (USGS) CALCULATED POINT PB 7.5 -MINUTE QUADRANGLE MAPS. IN ALL OTHER COUNTIES: CULVERTS GREATER THAN 48 INCHES UG FOG UNDERGROUND FIBER OPTIC CABLE SIGN IN DIAMETER WILL BE BURIED AT LEAST ONE FOOT BELOW THE BED OF THE STREAM. CULVERTS 48 �UG TCS UNDERGROUND TELEPHONE CABLE SIGN INCHES IN DIAMETER OR LESS SHALL BE BURIED OR PLACED ON THE STREAM BED AS �UG GAS UNDERGROUND GAS LINE SIGN PRACTICABLE AND APPROPRIATE TO MAINTAIN AQUATIC PASSAGE, AND EVERY EFFORT SHALL BE I I I DL-- L----CTV-----CTV- I I I I MADE TO MAINTAIN THE EXISTING CHANNEL SLOPE. THE BOTTOM OF THE CULVERT MUST BE �UG ELEC UNDERGROUND ELECTRIC LINE SIGN PLACED AT A 27 DEPTH BELOW THE NATURAL STREAM BOTTOM TO PROVIDE FOR PASSAGE DURING - - CTV- DROUGHT OR LOW FLOW CONDITIONS. LP LIGHT POLE 13. CULVERTS PLACED WITHIN RIPARIAN AND/OR RIVERINE WETLANDS MUST BE INSTALLED IN A OUP UTILITY POLE MANNER THAT DOES NOT RESTRICT THE FLOW AND CIRCULATION PATTERNS OF WATERS OF THE I I GUY WIRE ANCHOR UNITED STATES. CULVERTS PLACED ACROSS WETLAND FILLS PURELY FOR THE PURPOSES OF ®TSP TRAFFIC SIGNAL POLE EQUALIZING SURFACE WATER DO NOT HAVE TO BE BURIED. RXR RAILROAD CROSSING SIGNAL 14. PIPELINE/UTILITY LINE CONSTRUCTION THROUGH JURISDICTIONAL WATERS AND WETLANDS WILL BE o ACCOMPLISHED UTILIZING DIRECTIONAL DRILLING/BORING METHODS TO THE MAXIMUM EXTENT O MH MANHOLE PRACTICABLE. Q SSMH SANITARY SEWER MANHOLE 15. TEMPORARY DISCHARGE OF EXCAVATED OR FILL MATERIAL INTO WETLANDS AND WATERS OF THE ° OSDMH STORM DRAIN MANHOLE UNITED STATES WILL BE FOR THE ABSOLUTE MINIMUM PERIOD OF TIME NECESSARY TO ACCOMPLISH Q COMMH COMMUNICATION MANHOLE THE WORK. TEMPORARY DISCHARGES WILL BE FULLY CONTAINED WITH APPROPRIATE EROSION CONTROL OR CONTAINMENT METHODS OR OTHERWISE SUCH FILLS WILL CONSIST OF NON -ERODIBLE O ELMH ELECTRICAL MANHOLE MATERIALS. O ° J.B. JUNCTION BOX 16. THE WORK AREA AUTHORIZED BY THIS PERMIT, INCLUDING TEMPORARY AND/OR PERMANENT FILLS, SPIGOT SPIGOT/YARD HYDRANT WILL BE MINIMIZED TO THE GREATEST EXTENT PRACTICABLE. JUSTIFICATION FOR WORK CORRIDORS x EXCEEDING FORTY (40) FEET IN WIDTH IS REQUIRED AND WILL BE BASED ON PIPELINE DIAMETER O C.O. SEWER CLEAN-OUT AND LENGTH, SIZE OF EQUIPMENT REQUIRED TO CONSTRUCT THE UTILITY LINE, AND OTHER 0 E.SS ELECTRIC SERVICE STUB -OUT CONSTRUCTION INFORMATION DEEMED NECESSARY TO SUPPORT THE REQUEST. THE APPLICANT IS W REQUIRED TO PROVIDE THIS INFORMATION TO THE CORPS WITH THE INITIAL NOTIFICATION PACKAGE. 0 G.SS GAS SERVICE STUB -OUT 17. IN AREAS WHERE A SUB AQUEOUS UTILITY LINE IS TO CROSS A FEDERALLY MAINTAINED CHANNEL, ®CB CATCH BASIN (I.E., THE ATLANTIC INTRACOASTAL WATERWAY [AIWW]), THE LINE WILL BE BURIED AT LEAST SIX I --I rn (6) FEET BELOW THE ALLOWABLE OVERDEPTH OF THE AUTHORIZED CHANNEL, INCLUDING ALL SIDE ®cl CURB INLET SLOPES. FOR AREAS OUTSIDE FEDERALLY -MAINTAINED CHANNELS, SUB -AQUEOUS LINES MUST BE OWM WATER METER INSTALLED AT A MINIMUM DEPTH OF TWO (2) FEET BELOW THE SUBSTRATE WHEN SUCH LINES QFH FIRE HYDRANT MIGHT INTERFERE WITH NAVIGATION. w >a WV WATER VALVE 18. FOR THE PURPOSES OF THIS NWP ANY PERMANENTLY MAINTAINED CORRIDOR ALONG THE UTILITY BLOWOFF ROW WITHIN FORESTED WETLANDS SHALL BE CONSIDERED A PERMANENT IMPACT ANDA VALVE BLOW OFF VALVE COMPENSATORY MITIGATION PLAN WILL BE REQUIRED FOR ALL SUCH IMPACTS ASSOCIATED WITH b G/M GAS METER THE REQUESTED ACTIVITY. b G/V GAS VALVE 19. USE OF RIP -RAP OR ANY OTHER ENGINEERED STRUCTURES TO STABILIZE A STREAM BED SHOULD BE AVOIDED TO THE MAXIMUM EXTENT PRACTICABLE. IF RIPRAP STABILIZATION IS NEEDED, IT D -a IcV IRRIGATION CONTROL VALVE SHOULD BE PLACED ONLY ON THE STREAM BANKS, OR, IF IT IS NECESSARY TO BE PLACED IN C>a PIV POST INDICATOR VALVE THE STREAM BED, THE FINISHED TOP ELEVATION OF THE RIPRAP SHOULD NOT EXCEED THAT OF THE ORIGINAL STREAM BED ® E.JUNC ELECTRIC JUNCTION BOX OR OUTLET 20. WHEN DIRECTIONAL BORING OR HORIZONTAL DIRECTIONAL DRILLING (HDD) UNDER WATERS OF THE o TRAFFIC SIGNAL BOX U.S., INCLUDING WETLANDS, PERMITTEES SHALL CLOSELY MONITOR THE PROJECT FOR HYDRAULIC BSIG ox FRACTURING OR `TRACKING." ANY DISCHARGE FROM HYDRAULIC FRACTURING OR `TRACKING" INTO WATERS OF THE U.S., INCLUDING WETLANDS, SHALL BE REPORTED TO THE APPROPRIATE CORPS REGULATORY FIELD OFFICE WITHIN 48 HOURS. RESTORATION AND/OR MITIGATION MAY BE REQUIRED AS A RESULT FROM ANY UNINTENDED DISCHARGES. x x x NCDEQ GENERAL CONSTRUCTION CONDITIONS 1. THE CONTRACTOR SHALL MINIMIZE CLEARING WITHIN WETLANDS AND ACROSS STREAMS TO THE GREATEST EXTENT PRACTICABLE AND SHALL NOT EXCEED 50' WIDE FOR GAS UTILITY LINES AND 40' WIDE FOR ALL OTHER UTILITY LINES. EXCEPTIONS TO THIS CONDITION WILL REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. FOR CONSTRUCTION CORRIDORS IN WETLANDS AND ACROSS STREAM CHANNELS, STUMPS SHALL BE GRUBBED ONLY AS NEEDED TO INSTALL THE UTILITY AND REMAINING STUMPS SHALL BE CUT OFF AT GRADE LEVEL. THE GENERAL STRIPPING OF TOPSOIL WITHIN WETLANDS ALONG THE CONSTRUCTION CORRIDOR IS NOT PERMITTED. 2. PERMANENT MAINTAINED ACCESS CORRIDORS IN WETLANDS AND ACROSS STREAM CHANNELS SHALL BE RESTRICTED TO THE MINIMUM WIDTH PRACTICABLE AND SHALL NOT EXCEED 30' WIDE FOR GAS UTILITY LINES AND 20' WIDE FOR ALL OTHER UTILITY LINES EXCEPT AT MANHOLE LOCATIONS. 15' X 15' PERPENDICULAR VEHICLE TURN-AROUNDS ARE ALLOWED IN ACCESS CORRIDORS BUT MUST BE SPACED AT LEAST 500' APART. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 3. THE CONTRACTOR SHALL HAVE A SPECIFIC PLAN FOR RESTORING WETLAND CONTOURS. ANY EXCESS MATERIAL SHALL BE REMOVED TO A HIGH GROUND DISPOSAL AREA. THE MIXING OF TOPSOIL AND SUBSOILS WITHIN WETLANDS ALONG UTILITY CORRIDORS SHALL BE MINIMIZED TO THE GREATEST EXTENT PRACTICABLE DURING EXCAVATION. THE SOILS SHALL BE PLACED ON FABRIC TO MINIMIZE IMPACTS WHENEVER POSSIBLE. TOPSOIL EXCAVATED FROM UTILITY TRENCHES SHALL BE PILED SEPARATELY FROM SUBSOILS AND BACKFILLED INTO THE TRENCH ONLY AFTER THE SUBSOILS HAVE BEEN PLACED AND COMPACTED. 4. NO WASTE, SPOIL, SOLIDS, OR FILL OF ANY KIND CAN OCCUR IN WETLANDS OR WATERS BEYOND THE FOOTPRINT OF THE IMPACT AREA (INCLUDING TEMPORARY IMPACTS) OR BEYOND THE PERMITTED THRESHOLDS WITHOUT WRITTEN AUTHORIZATION FROM THE PROJECT ENGINEER. NO REMOVAL OF VEGETATION OR OTHER IMPACTS OF ANY KIND CAN OCCUR TO STATE REGULATED RIPARIAN BUFFERS BEYOND THE FOOTPRINT OF IMPACTS APPROVED IN A BUFFER AUTHORIZATION OR VARIANCE OR AS LISTED AS AN EXEMPT ACTIVITY IN THE APPLICABLE RIPARIAN BUFFER RULES. 5. ALL EROSION CONTROL DEVICES SHALL BE MAINTAINED ON ALL CONSTRUCTION SITES, BORROW SITES, AND WASTE PILE (SPOIL) SITES, INCLUDING CONTRACTOR OWNED OR LEASED BORROW PITS ASSOCIATED WITH THE PROJECT. SUFFICIENT MATERIALS REQUIRED FOR STABILIZATION AND/OR REPAIR OF EROSION CONTROL MEASURES AND STORMWATER ROUTING AND TREATMENT SHALL BE ON-SITE AT ALL TIMES. 6. SEDIMENT AND EROSION CONTROL MEASURES SHALL NOT BE PLACED IN WETLANDS OR WATERS EXCEPT WITHIN THE FOOTPRINT OF TEMPORARY OR PERMANENT IMPACTS AUTHORIZED UNDER THE PERMITS. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 7. EROSION CONTROL MATTING THAT INCORPORATES PLASTIC MESH AND/OR PLASTIC TWINE SHALL NOT BE USED ALONG STREAMBANKS OR WITHIN WETLANDS. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 8. AN NPDES CONSTRUCTION STORMWATER PERMIT (NCGO10000) IS REQUIRED FOR CONSTRUCTION PROJECTS THAT DISTURB ONE OR MORE ACRES OF LAND. THE NCGO10000 PERMIT ALLOWS STORMWATER TO BE DISCHARGED DURING LAND DISTURBING CONSTRUCTION ACTIVITIES AS STIPULATED IN THE CONDITIONS OF THE PERMIT. IF THE PROJECT IS COVERED BY THE PERMITS, FULL COMPLIANCE WITH PERMIT CONDITIONS INCLUDING THE EROSION AND SEDIMENTATION CONTROL PLAN, INSPECTIONS AND MAINTENANCE, SELF-MONITORING, RECORD KEEPING AND REPORTING REQUIREMENTS IS REQUIRED. 9. ALL WORK IN OR ADJACENT TO STREAMS SHALL BE CONDUCTED SO THAT THE FLOWING STREAM DOES NOT COME IN CONTACT WITH THE DISTURBED AREA. APPROVED BEST MANAGEMENT PRACTICES FROM THE MOST CURRENT VERSION OF THE INC SEDIMENT AND EROSION CONTROL MANUAL, OR THE NC DOT CONSTRUCTION AND MAINTENANCE ACTIVITIES MANUAL, SUCH AS SANDBAGS, ROCK BERMS, COFFERDAMS, AND OTHER DIVERSION STRUCTURES SHALL BE USED TO MINIMIZE EXCAVATION IN FLOWING WATER. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 10. CULVERTS SHALL BE INSTALLED IN SUCH A MANNER THAT THE ORIGINAL STREAM PROFILES ARE NOT ALTERED AND ALLOW FOR AQUATIC LIFE MOVEMENT DURING LOW FLOWS. THE DIMENSION PATTERN AND PROFILE OF THE STREAM ABOVE AND BELOW A PIPE OR CULVERT SHALL NOT BE MODIFIED BY WIDENING THE STREAM CHANNEL OR BY REDUCING THE DEPTH OF THE STREAM IN CONNECTION WITH THE CONSTRUCTION ACTIVITY. 11. APPLICATION OF FERTILIZER TO ESTABLISH PLANTED/SEEDED VEGETATION WITHIN DISTURBED RIPARIAN AREAS SHALL COMPLY WITH ALL OTHER FEDERAL, STATE AND LOCAL REGULATIONS. FERTILIZER APPLICATION SHALL BE ACCOMPLISHED IN A MANNER THAT MINIMIZES THE RISK OF CONTACT BETWEEN THE FERTILIZER AND SURFACE WATERS. 12. IF CONCRETE IS USED DURING CONSTRUCTION, THEN ALL NECESSARY MEASURES SHALL BE TAKEN TO PREVENT DIRECT CONTACT BETWEEN UNCURED OR CURING CONCRETE AND WATERS OF THE US. WATER THAT INADVERTENTLY CONTACTS UNCURED CONCRETE SHALL NOT BE DISCHARGED TO WATERS OF THE US. 13. ALL PROPOSED AND APPROVED TEMPORARY FILL AND CULVERTS SHALL BE REMOVED AND THE IMPACTED AREA RETURNED TO NATURAL CONDITIONS WITHIN 60 CALENDAR DAYS AFTER THE TEMPORARY IMPACT IS NO LONGER NECESSARY. THE IMPACTED AREAS SHALL BE RETURNED TO ORIGINAL GRADE, INCLUDING EACH STREAM'S ORIGINAL CROSS SECTIONAL DIMENSIONS, PLANFORM PATTERN, AND LONGITUDINAL BED PROFILE. ALL TEMPORARY IMPACTS SHALL BE RESTORED AND STABILIZED WITH NATIVE VEGETATION. 14. ALL PROPOSED AND APPROVED TEMPORARY PIPES/CULVERTS/RIP-RAP PADS ETC. IN STREAMS SHALL BE INSTALLED AS OUTLINED IN THE MOST RECENT EDITION OF THE NC SEDIMENT AND EROSION CONTROL PLANNING AND DESIGN MANUAL OR THE NCDOT BEST MANAGEMENT PRACTICES FOR CONSTRUCTION AND MAINTENANCE ACTIVITIES SO AS NOT TO RESTRICT STREAM FLOW OR CAUSE DIS -EQUILIBRIUM DURING USE OF THIS CERTIFICATION. 15. ANY RIP -RAP REQUIRED FOR PROPER CULVERT PLACEMENT, STREAM STABILIZATION, OR RESTORATION OF TEMPORARILY DISTURBED AREAS SHALL BE RESTRICTED TO THE AREA DIRECTLY IMPACTED BY THE APPROVED CONSTRUCTION ACTIVITY. ALL RIP -RAP SHALL BE PLACED SUCH THAT THE ORIGINAL STREAM ELEVATION AND STREAM BANK CONTOURS ARE RESTORED AND MAINTAINED, NOT RESULT IN THE DE -STABILIZATION OF STREAM BED OR BANKS UPSTREAM OR DOWNSTREAM OF THE AREA, AND NOT RESTRICT AQUATIC LIFE PASSAGE. 16. ANY RIP -RAP USED FOR STREAM OR SHORELINE STABILIZATION SHALL BE OF SIZE AND DENSITY TO PREVENT MOVEMENT BY WAVE, CURRENT, OR STREAM FLOWS, AND WILL CONSIST OF CLEAN ROCK OR MASONRY MATERIAL. RIP -RAP SHALL NOT BE INSTALLED IN THE STREAMBED EXCEPT IN SPECIFIC AREAS REQUIRED FOR VELOCITY CONTROL AND TO ENSURE STRUCTURAL INTEGRITY OF BANK STABILIZATION MEASURES. 17. ALL MECHANIZED EQUIPMENT OPERATED NEAR SURFACE WATERS SHALL BE INSPECTED, FUELED, LUBRICATED, AND MAINTAINED REGULARLY AND MAINTENANCE PERFORMED IN A MANNER TO PREVENT CONTAMINATION OF STREAM WATER FROM FUELS, LUBRICANTS, HYDRAULIC FLUIDS, OR OTHER TOXIC MATERIALS. 18. HEAVY EQUIPMENT WORKING IN WETLANDS SHALL BE PLACED ON MATS OR OTHER MEASURES TAKEN TO MINIMIZE SOIL DISTURBANCE. 19. THE CONTRACTOR OR OTHER RESPONSIBLE ENTITY SHALL REPORT ANY PETROLEUM SPILL OF 25 GALLONS OR MORE; ANY SPILL REGARDLESS OF AMOUNT THAT CAUSES A SHEEN ON SURFACE WATERS; ANY PETROLEUM SPILL REGARDLESS OF SIZE THAT OCCURS WITHIN 100 -FEET OF SURFACE WATER; AND ANY PETROLEUM SPILL LESS THAN 25 GALLONS THAT CANNOT BE CLEANED UP WITHIN 24 HOURS. -o-o-o-o-o-o-o-o-o-o-o-o-o-o- IRON PIN SET RBF REBAR FOUND OTIPF OPEN TOP IRON PIN FOUND CTIPF ----s-----s CMU CONCRETE MASONRY UNIT R/W RIGHT OF WAY CL CENTERLINE ----w-----w CURVE (SEE CURVE TABLE) POB POINT OF BEGINNING CP CALCULATED POINT PB I I I I I I I I I I I I I I I I I I I I I -----G-----G- I I I I I I I -- DL----- I I I I I I DL----- I I I I I I DL-- L----CTV-----CTV- I I I I CONCRETE - -CTV - - - - - CTV- 0 U CTV CTV v O U U) 0 U) -----FOC-----FOC- OQ O 006 o ----E-----E 0. �O Z U _ E z vJ w E ----T-----T I ---I > -T- -T- -----ROW -----ROW0000000000 - u U IPS IRON PIN SET RBF REBAR FOUND OTIPF OPEN TOP IRON PIN FOUND CTIPF CRIMPED TOP IRON PIN FOUND CMU CONCRETE MASONRY UNIT R/W RIGHT OF WAY CL CENTERLINE C CURVE (SEE CURVE TABLE) POB POINT OF BEGINNING CP CALCULATED POINT PB PLAT BOOK DB DEED BOOK L LINE (SEE LINE TABLE) BLDG BUILDING CIP CAST IRON PIPE CMP CORRUGATED METAL PIPE CONC CONCRETE NO. I DATE I BY 0 CALCULATED POINT GIPS 1/2" REBAR SET WITH CAP ® CONCRETE MONUMENT ®CM-R/W RIGHT-OF-WAY MONUMENT ODOT MON D.O.T. CONTROL POINT 0RBF REBAR FOUND ORRSPIKE RAILROAD SPIKE o PK NL PK NAIL FOUND / SET SPINDLE SPINDLE FOUND / SET ®CPHUB HUB & TACK SET ACP/NL GPS CONTROL POINT NAIL SET / FOUND OCP/NL CONTROL POINT/NAIL SET GPS OCP/TEMP CONTROL POINT TEMPORARY MARK * NGS METAL ROD NATIONAL GEODETIC SURVEY METAL ROD ® NGS CM NATIONAL GEODETIC SURVEY CONCRETE MONUMENT NGS TEMPORARY CONTROL POINT SET ® NETWORK TRIANGULATION POINT ASTAKE STAKE FOUND 7 40 INTERSTATE HIGHWAY 66 U.S. HIGHWAY } FFE -7-ELEVATIONFINISHED FLOOR ELEVATION e Mw MONITORING WELL OPZ PIEZOMETER ® LANDFILL GAS MONITORING PROBE O SURFACE WATER SAMPLING LOCATION LANDFILL GAS VENT 0 LANDFILL GAS COLLECTION WELLHEAD Qw POTABLE WATER WELL OMB MAILBOX OR PAPER BOX ❑PB POSTAL DROP BOX .)SAT DISH SATELLITE DISH OYARD ORNAMENT STATUE, BIRD BATHS, ETC. TREES 0 SHRUBS / BUSHES (H) HORIZONTAL GROUND DISTANCE (G) NC STATE PLANE GRID DISTANCE CULVERT FENCE SILT FENCE GUARD RAIL APPROXIMATE LOCATION OF EXISTING SEWER LINES APPROXIMATE LOCATION OF EXISTING WATER LINES APPROXIMATE LOCATION OF EXISTING GAS LINES TOP OF SLOPE TOE OF SLOPE DITCH LINES APPROXIMATE LOCATION OF UNDERGROUND CABLE TV LINE APPROXIMATE LOCATION OF OVERHEAD CABLE TV LINE APPROXIMATE LOCATION OF UNDERGROUND FIBER OPTIC CABLE LINE APPROXIMATE LOCATION OF UNDERGROUND ELECTRIC LINE APPROXIMATE LOCATION OF OVERHEAD ELECTRIC LINE APPROXIMATE LOCATION OF UNDERGROUND TELEPHONE LINES APPROXIMATE LOCATION OF OVERHEAD TELEPHONE LINES RIGHT-OF-WAY TREELINE SHRUBLINE PROPERTY LINE NOT SURVEYED ROCKLINE STREAM LINE CENTERLINE CENTERLINE VARIANT SWAM PLINE/WETLANDS APPROXIMATE LOCATION OF OVERHEAD UTILITY LINE CMU CONCRETE MASONRY UNIT CPP CORRUGATED PLASTIC PIPE DIP DUCTILE IRON PIPE E&T ELECTRIC & TELEPHONE FOC FIBER OPTIC CABLE GIP GALVANIZED IRON PIPE 0/H OVERHEAD RCP REINFORCED CONCRETE PIPE U/G UNDERGROUND VCP VITRIFIED CLAY PIPE PVC POLYVINYL CHLORIDE PIPE FFE FINISHED FLOOR ELEVATION PG PAGE REF REFERENCE DOT DEPARTMENT OF TRANSPORTATION NGS NATIONAL GEODETIC SYRVEY NCSP NORTH CAROLINA STATE PLANE MTR BOX METER BOX REVISION DESCRIPTION �wC71, U Q z Z U� 00 � J WZ� W �z O� >0U W U 00 O W VJ (D= O 0 H � o �/J U)v Q Z 0 U c� v O U U) 0 U) Z OQ O 006 o 0. �O Z U _ � z vJ w I ---I > x w wE-� W z I --I rn Q AF11`J w CD CD N 06 LU in Q > >CO L � � LU LU g ~ � z m z Q CO -0 z uj C7 p C� C!) z = mO Q w Q w O w C6= � p p U p U E= Cn 0 Z V J W0 Ow Z (D W N< J ry W Z rW V SHEET G-002 U Q z Z J 00 � J W 0 O� >0U 00 O W VJ (D= O 0 'Z U)� � II.I.- �/J U)v Q Z 0 U Up O U U) 0 U) Z OQ O 006 cn 0. �O Z w Z _ a- W vJ = CD CD N 06 LU in Q > >CO L � � LU LU g ~ � z m z Q CO -0 z uj C7 p C� C!) z = mO Q w Q w O w C6= � p p U p U E= Cn 0 Z V J W0 Ow Z (D W N< J ry W Z rW V SHEET G-002 S GENERAL SEWER NOTES Q4) ALL CONSTRUCTION OUTSIDE RIGHTS-OF-WAY SHALL TAKE PLACE WITHIN THE PERMANENT AND TEMPORARY ACCESS EASEMENTS SHOWN. 22. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING ROADS DURING CONSTRUCTION = AND SHALL REPAIR ROADS PER REQUIREMENTS OF THE NORTH CAROLINA DEPARTMENT OF 2. CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS TO EQUAL OR BETTER CONDITION THAN THE TRANSPORTATION. NO OPEN CUTS OF EXISTING ROADS SHALL BE ALLOWED EXCEPT WHERE INDICATED ON ORIGINAL SITE, OR AS NOTED. THE DRAWINGS OR WHERE SPECIFIC PERMISSION IS GRANTED BY THE NORTH CAROLINA DEPARTMENT OF 3. LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY. EXACT LOCATIONS ARE TO BE TRANSPORTATION. SAND OR A SIMILAR MATERIAL APPROVED BY THE NORTH CAROLINA DEPARTMENT OF VERIFIED IN THE FIELD BY THE CONTRACTOR. AT LEAST THREE DAYS PRIOR TO CONSTRUCTION, TRANSPORTATION SHALL BE PLACED ON THE ROAD TO AID IN THE CLEAN UP AFTER CONSTRUCTION. A CONTRACTOR MUST NOTIFY EXISTING UTILITY OWNERS. CALL 811 BEFORE YOU DIG. MINIMUM OF 2" OF SAND SHALL BE PLACED ON THE ROAD PRIOR TO STOCKPILING SPOIL MATERIAL ON THE ROAD SURFACE TO FACILITATE CLEANUP. 4. ALL WORK NEAR AND AROUND WATERWAYS MUST CONFORM TO THE RULES OF THE STATE OF NORTH NN CAROLINA. 23. CONTRACTOR SHALL MAINTAIN SEWAGE FLOW IN SEWER SYSTEM AT ALL TIMES AND SHALL PROVIDE 5. CONTRACTOR MUST PROVIDE EROSION CONTROL DEVICES TO CONTROL RUNOFF FROM THE BYPASS PUMPING AND/OR PIPING AS REQUIRED. NO SANITARY SEWER OVERFLOWS ARE PERMITTED. CONSTRUCTION SITE. CONTRACTOR WILL BE RESPONSIBLE FOR ANY FINES THAT MAY BE LEVIED DUE ~ W TO POLLUTION CREATED DURING CONSTRUCTION. 24. SPECIFICATIONS AND REQUIREMENTS BY MSD SUPERSEDE ALL OTHERS IN THE INSTALLATION OF THE PROPOSED EXTENSION. 6. CONTRACTOR SHALL FOLLOW ALL FEDERAL, STATE AND LOCAL HEALTH AND SAFETY REGULATIONS PERTAINING TO CONSTRUCTION OPERATIONS. 7. SEWER FORCE MAINS AND WATER LINES SHALL HAVE 3'-0" MINIMUM COVER UNLESS OTHERWISE SHOWN ON THE DRAWINGS. 8. WATER AND SEWER LINES SHALL HAVE A MINIMUM 10' HORIZONTAL SEPARATION OR A MINIMUM 18" VERTICAL SEPARATION WITH THE WATER OVER SEWER, OR BOTH WATER AND SEWER LINES SHALL BE DUCTILE IRON PIPE 10' EITHER SIDE OF THE CROSSING. 9. SEWER AND STORM SEWER LINES SHALL HAVE A MINIMUM 18" SEPARATION. IF 18" SEPARATION IS NOT OBTAINABLE, DUCTILE IRON PIPE SHALL BE USED FOR THE SEWER LINE OR A SUPPORTING MATERIAL SUCH AS FLOWABLE FILL SHALL BE INSTALLED BETWEEN THE PIPES. 10. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION. 11. UNLESS OTHERWISE NOTED, ALL BURIED PIPE SHALL BE INSTALLED WITH PUSH -ON JOINTS AND EXPOSED PIPING SHALL BE FLANGED JOINT. 12. LEGAL DESCRIPTIONS FOR PROPOSED EASEMENTS BY OTHERS. 13. SITE TOPOGRAPHIC AND BOUNDARY SURVEY PROVIDED BY SURVEYOR NOTED ON PLANS. 14. CONTRACTOR SHALL NOTIFY THE PROPER LOCAL AUTHORITIES 24 HOURS PRIOR TO ANY ROAD BEING CLOSED FOR CONSTRUCTION, INCLUDING BUT NOT LIMITED TO LOCAL NEWSPAPER, RADIO STATION, FIRE DEPARTMENT, COUNTY SHERIFF'S DEPARTMENT, AMBULANCE, AND COUNTY EMERGENCY AGENCY. ALL TRAFFIC CONTROL SHALL CONFORM TO THE REQUIREMENTS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION. 15. CONTRACTOR SHALL NOTIFY THE ENGINEER AFTER EXISTING BURIED UTILITIES HAVE BEEN LOCATED AND 24 HOURS PRIOR TO CONSTRUCTION. 16. LOCATIONS SHOWN FOR SANITARY SEWER SERVICES ARE ASSUMED. COORDINATE LOCATIONS OF ALL PROPOSED SEWER SERVICE CONNECTIONS WITH PROPERTY OWNER PRIOR TO CONSTRUCTION. 17. CONTRACTOR SHALL FIELD VERIFY ALL PROPOSED MANHOLE TOP ELEVATIONS AND EXISTING MANHOLE INVERTS PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. CONTRACTOR SHALL ADJUST ALL PROPOSED SEWER STRUCTURES TO MATCH FINISHED PAVEMENT ELEVATIONS. COSTS OF RAISING STRUCTURES SHALL BE CONSIDERED INCIDENTAL TO OTHER WORK ON THE PROJECT. 18. MANHOLES AND CASTINGS SHALL MEET THE REQUIREMENTS OF OWNER AS WELL AS THE PROJECT SPECIFICATIONS. 19. 4" SANITARY SEWER SERVICE LINES SHALL BE INSTALLED AT 2.0% MINIMUM SLOPE AND SHALL BE DUCTILE IRON IN PAVED AREAS. 20. ALL FENCE DAMAGED DURING CONSTRUCTION SHALL BE REPLACED WITH LIKE MATERIALS IN A WORKMANLIKE MANNER AND IN ACCORDANCE WITH STANDARD FENCE CONSTRUCTION PRACTICES AT THE CONTRACTOR'S EXPENSE. 21. CONTRACTOR SHALL FIELD LOCATE ALL BURIED TELEPHONE LINE IN CONFLICT WITH THE PROPOSED UTILITY LINE. WHERE NECESSARY, EXISTING BURIED TELEPHONE LINE SHALL BE TEMPORARILY MOVED DURING CONSTRUCTION OF THE PROPOSED UTILITY LINE AND RE-LAID AT NO ADDITIONAL COST TO THE OWNER. 25. INSTALLATION OF PROPOSED SEWER EXTENSION AND ALL PUBLIC SANITARY SEWER WORK ASSOCIATED WITH PROJECT TO BE PERFORMED BY NORTH CAROLINA LICENSED UTILITY CONTRACTOR. 26. CONTRACTOR SHALL PROVIDE CCSD FIELD DENSITY REPORTS VERIFYING SEWER BUILT IN FILL AREAS ARE COMPACTED TO 95% STANDARD PROCTOR. 27. PERMANENT PUBLIC EASEMENT TO BE CLEARED AND REMAIN CLEAR OF ANY TREES AND/OR PERMANENT 28. STRUCTURES. A LANDSCAPE PLAN IS NOT INCLUDED IN THE SCOPE OF THIS PROJECT. SPECIFICATIONS AND REQUIREMENTS OF THE METROPOLITAN SEWERAGE DISTRICT SUPERSEDE ALL OTHERS IN THE INSTALLATION OF THE PROPOSED EXTENSION. 29. THE INSTILLATION OF THE PROPOSED SEWER EXTENSION AND ALL PUBLIC SANITARY SEWER WORK ASSOCIATED WITH THIS PROJECT TO BE PERFORMED BY NC LICENSED UTILITY CONTRACTOR. 30. PROJECT SITE IS LOCATED OUTSIDE OF 100 -YR FLOODPLAIN. 1. WATER CONSTRUCTION ON THIS SITE IS AUTHORIZED BY PERMITS ISSUED BY THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY (NCDEQ) AND AUTHORIZED BY THE CITY OF HENDERSONVILLE. THE WORK IS SUBJECT TO INSPECTIONS AT ALL TIMES BY REPRESENTATIVES OF NCDEQ, THE CITY OF HENDERSONVILLE, THE OWNER OR THE ENGINEER. THE PERMITS REQUIRE CERTIFICATION OF COMPLETION OF THE WATER SYSTEMS BY THE ENGINEER AND THE APPLICANT PRIOR TO ISSUANCE OF FINAL OPERATION APPROVAL. 2. MATERIALS AND INSTALLATION FOR WATER CONSTRUCTION SHALL CONFORM TO THE LATEST VERSIONS OF CITY SPECIFICATION AND DETAILS AND AWWA STANDARDS AND REQUIREMENTS. 3. CONTRACTOR SHALL NOTIFY NC811 & APPROPRIATE UTILITIES AGENCIES PRIOR TO PERFORMING ANY WORK. 4. REGULAR WORKING HOURS SHALL BE FROM 7:00 AM TO 5:00 PM MONDAY THROUGH FRIDAY, EXCEPT IN CASES OF EMERGENCY OR OTHERWISE APPROVED IN WRITING BY THE CITY OR AUTHORIZED REPRESENTATIVES. THE CONTRACTOR SHALL ENSURE THE CONSTRUCTION SITE IS SAFE FOR ANY PERSONS WHO MAY BE ON SITE DURING NON -WORKING HOURS. 5. ALL PERSONS SHALL BE COURTEOUS AND RESPECTFUL TO THE PUBLIC. CURSING OUR FOUL LANGUAGE IS NOT PERMITTED AND WILL NOT BE TOLERATED. 6. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING TRAFFIC CONTROL ON ALL ROADWAYS DURING THE PROJECT. THE CONTRACTOR SHALL NOTIFY LOCAL EMERGENCY, SCHOOL AND OTHER NECESSARY AUTHORITIES PRIOR TO ANY STREET CLOSING OR TRAFFIC CHANGE. 7. THE CONTRACTOR AT HIS OWN EXPENSE SHALL KEEP THE CONSTRUCTION SITE AND ADJACENT PUBLIC AND PRIVATE ROADWAYS CLEAN DURING THE PROJECT. THE CONTRACTOR IS ALSO RESPONSIBLE FOR CONTROLLING DUST WITHIN THE PROJECT AREA. 8. THE CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION IN ACCORDANCE WITH THE LINES, GRADES AND ELEVATIONS SHOWN ON THE PLANS OR AS GIVEN BY THE ENGINEER IN THE FIELD. 9. CONTRACTOR SHALL VERIFY THE EXACT LOCATION AND THE ELEVATION FOR ALL UTILITIES, DRAINAGE AND OTHER UNDERGROUND FACILITIES BOTH EXISTING AND PROPOSED, AND SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO CONSTRUCTION. 10. CONTRACTOR SHALL PROTECT EXISTING UTILITIES DURING CONSTRUCTION. REPAIRS SHALL BE MADE IN ACCORDANCE WITH APPLICABLE STANDARDS OF APPROPRIATE AGENCIES AT THE CONTRACTOR'S EXPENSE. 11. DURING CONSTRUCTION THE CONTRACTOR SHALL MAINTAIN THE OPERATION OF EXISTING UTILITIES WITH THE LEAST AMOUNT OF SERVICE INTERRUPTION POSSIBLE IN COORDINATION WITH THE CITY OF HENDERSONVILLE. CONTINUOUS SERVICE, PUBLIC HEALTH AND SAFETY CONSIDERATIONS SHALL EXCEED ALL OTHERS AND CONTRACTOR'S SCHEDULE, PLANS AND WORK SHALL AT ALL TIMES BE SUBJECT TO ALTERATION AND REVISION IF NECESSARY FOR THESE CONSIDERATIONS. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE TEMPORARY OR PERMANENT RELOCATION OF STRUCTURES AND UTILITIES, INCLUDING BUT NOT LIMITED TO POLES, SIGNS, FENCES, HYDRANTS, VALVES, PIPING, CONDUITS AND DRAINS THAT INTERFERE WITH THE POSITIONING OF THE WORK AS SHOWN ON THE DRAWINGS. 13. CONTRACTOR SHALL BE REQUIRED TO CONFORM AND COMPLY WITH ALL RESTRICTIONS AND EASEMENT CONDITIONS AND IS RESPONSIBLE FOR ALL RELATED INCIDENTAL COSTS INVOLVED. 14. EXISTING WATER SERVICES SHALL BE REPLACED TO THE EXISTING METER UNLESS OTHERWISE APPROVED IN WRITING BY THE CITY. SPLICING OF THE WATER SERVICE ON THE DOWNSTREAM SIDE OF THE METER IS NOT PERMITTED. 15. ALL DISTURBED AREAS, INCLUDING BUT NOT LIMITED TO ASPHALT, CONCRETE, DRIVEWAYS, ROADS, LANDSCAPING, SHALL BE REPAIRED TO EQUAL OR BETTER CONDITION THAN THE ORIGINAL SITE. GRASS AND LANDSCAPED AREAS FILL MATERIAL MUST BE REPLACED IN TRENCH TO GRADE AS SOON AS WATERLINE CONSTRUCTION ALLOWS. ADEQUATE SEEDING AND STRAW OR MULCH SHALL THEN BE APPLIED TO THE DISTURBED TRENCH AREA. ADDITIONAL FILL AND SITE RESTORATION MAY BE REQUIRED WITHIN THE WARRANTY PERIOD AT THE CITY'S DISCRETION. 16. CONTRACTOR SHALL PROVIDE EROSION CONTROL DEVICES TO CONTROL RUNOFF AS REQUIRED. THE CONTRACTOR IS RESPONSIBLE FOR ANY FINES THAT MAY BE LEVIED DUE TO RUNOFF FROM CONSTRUCTION. 17. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FOLLOW ALL APPLICABLE FEDERAL, STATE AND LOCAL HEALTH AND SAFETY REGULATIONS PERTAINING TO CONSTRUCTION OPERATIONS. 18. ALL WATER MAINS SHALL HAVE 3 FEET MINIMUM COVER. 19. INSTALL FERROUS PIPING FOR BOTH WATER AND SEWER WITHIN 10 FT. OF A CROSSING IF: 19.1. SEWER LINE CROSSES OVER WATER, QH 19.2. VERTICAL CLEARANCE BETWEEN WATER AND SEWER IS LESS THAN 18 INCHES. 19.3. MAINTAIN 10 FEET HORIZONTAL SEPARATION BETWEEN SEWER AND WATER MAINS UNLESS LAID IN SEPARATE TRENCHES WITH THE BOTTOM OF THE WATER LINE AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER LINE OR USE FERROUS MATERIAL FOR BOTH WATER AND SEWER. 20. MAINTAIN 18 INCHES VERTICAL SEPARATION BETWEEN STORM DRAIN AND WATER, OR INSTALL FERROUS MATERIAL WATER LINE WITHIN 10 FEET EACH SIDE OF CROSSING. 21. TAPS GREATER THAN ONE -INCH IN DIAMETER IN EXISTING, ACTIVE WATER MAIN ARE TO BE PERFORMED BY THE CITY UNLESS OTHERWISE APPROVED IN WRITING BY THE CITY. TAPS IN NEW CONSTRUCTION ARE TO BE PERFORMED BY THE CONTRACTOR IN ACCORDANCE WITH CITY REQUIREMENTS. 22. ALL WATER METERS WILL BE SET BY CITY STAFF UNLESS THE CONTRACTOR IS GRANTED WRITTEN PERMISSION BY THE CITY. 22.1. THE CONTRACTOR WILL PROVIDE THE CITY NOTICE OF 10 WORKING DAYS MINIMUM PRIOR TO THE DATE OF METER INSTALLATION. 22.2. THE CONTRACTOR WILL PROVIDE A LICENSED PLUMBER DURING THE METER INSTALLATION TO VERIFY LINE SERVICES IN ALL MULTI -METER BOXES. 23. ALL PUBLIC WATER MAIN CONSTRUCTION SHALL BE PERFORMED BY A NORTH CAROLINA LICENSED UTILITY CONTRACTOR. 24. ALL WATER APPURTENANCES ARE TO BE MADE USING LEAD FREE MATERIALS. PIPE, FITTINGS, VALVES, HYDRANTS, PIPE CLAMPS, RESTRAINTS, FLANGES, CASTINGS, REBAR, HATCHES, INLETS, METER BOXES AND ALL OTHER CAST IRON COMPONENTS SHALL BE MANUFACTURED IN THE USA. 25. RESTRAINED JOINTS BY AN APPROVED PIPE MANUFACTURER ARE TO BE USED FOR ALL PUBLIC WATER LINES WHERE THRUST RESTRAINING IS REQUIRED IN ACCORDANCE WITH THE PLANS AND MANUFACTURER'S SPECIFICATION. CONCRETE THRUST BLOCKS ARE PERMITTED ONLY WHERE CONNECTIONS ARE MADE TO EXISTING WATER LINES OR WHERE THE USE OF MECHANICAL RESTRAINT IS NOT FEASIBLE. 26. ALL FIRE HYDRANTS, VAULTS, BACKFLOW PREVENTERS, HOT BOXES AND WATER METERS ARE TO BE INSTALLED ON RELATIVELY FLAT AREAS OUTSIDE OF PAVEMENT. 27. TAMPERING WITH OR ILLEGAL USE OF THE PUBLIC WATER SUPPLY WILL RESULT IN SUSPENSION OF WATER SERVICE, INCLUDING DOMESTIC AND COMMERCIAL, UNTIL FINAL APPROVAL BY THE CITY IS ISSUED. A PERSON FOUND TO BE USING WATER ILLEGALLY SHALL BE SUBJECT TO PENALTIES OR FINES, AS PRESCRIBED AND APPROVED BY CITY COUNCIL. TESTING & INSPECTION: 1. NOTIFY THE CITY OF HENDERSONVILLE AND ENGINEER AT LEAST 5 WORKING DAYS BEFORE STARTING CONSTRUCTION OF WATER FACILITIES TO SCHEDULE A PRE -CONSTRUCTION CONFERENCE. THE ENGINEER SHALL PERIODICALLY INSPECT THE PROGRESS OF INSTALLATION AT A MINIMUM AND SHALL COMPLETE A FINAL WATER CERTIFICATION. 2. ALL CHANGES TO THE APPROVED CONSTRUCTION PLANS AND SUBMITTALS MUST BE APPROVED IN WRITING BY THE CITY PRIOR TO IMPLEMENTATION IN THE FIELD. 3. THE CONTRACTOR SHALL FURNISH SECURE AND PROVIDE ALL NECESSARY TESTING MATERIALS, EQUIPMENT, LABOR. THE CONTRACTOR SHALL COORDINATE TESTING, FLUSHING, DISINFECTION, AND BACTERIOLOGICAL SAMPLING WITH CITY INSPECTOR. 4. THE ENGINEER OR CONTRACTOR SHALL NOTIFY THE CITY CONSTRUCTION INSPECTORS 72 HOURS (MINIMUM) PRIOR TO ANY WATER MAIN OR TESTING OPERATIONS. AT A MINIMUM CITY STAFF SHALL BE NOTIFIED PRIOR TO TAPS, TESTING, FLUSHING, DISINFECTION, AND SAMPLING. 5. PRESSURE TEST WATER MAINS TO 200 PSI MIN. FOR A MINIMUM OF TWO HOURS IN ACCORDANCE WITH CITY REQUIREMENTS AND AWWA C600. 6. DISINFECT WATER LINES AND PROVIDE ACCEPTABLE BACTERIOLOGICAL TEST FROM A CERTIFIED TESTING LABORATORY IN ACCORDANCE WITH CITY REQUIREMENTS AND AWWA C651. THE CONTRACTOR MAY ELECT TO USE THE CITY'S CERTIFIED TESTING LABORATORY. 7. PRIVATELY OWNED FIRE SYSTEMS SHALL BE APPROVED BY THE APPROPRIATE LOCAL PERMITTING AUTHORITY. THE CITY ENGINEERING OR WATER AND SEWER DEPARTMENTS ARE NOT RESPONSIBLE FOR ENSURING COMPLIANCE WITH APPROPRIATE FIRE PROTECTION REGULATIONS. THE CITY DOES NOT PROVIDE ANY GUARANTEE OF ITS WATER SYSTEM'S CAPABILITY TO DELIVER WATER FLOW AND RESIDUAL PRESSURE THE FIRE PERMITTING AUTHORITY MAY REQUIRE. 8. ALL BACKFLOW PREVENTION ASSEMBLIES SHALL BE USC APPROVED AND REVIEWED BY THE CITY'S. PROTECTION OF THE PUBLIC WATER DISTRIBUTION SYSTEM SHALL BE ASSURED BY INSPECTION OF THE INSTALLATION AND TESTING OF BACKFLOW PREVENTION DEVICES IN ACCORDANCE WITH APPROPRIATE LOCAL, STATE, AND FEDERAL REGULATIONS. 9. CONSTRUCTION WATER SOURCING MUST BE APPROVED IN WRITING BY THE CITY. CONSTRUCTION WATER CONNECTIONS SHALL BE PAIRED WITH AN IRRIGATION METER AND APPROVED BACKFLOW PREVENTION ASSEMBLY. THIS ASSEMBLY INSTALLATION MUST BE TESTED BY A LICENSED PLUMBER AND TEST RESULTS SUBMITTED TO THE CITY BEFORE USE OF CONSTRUCTION WATER. 10. SECURE FINAL WRITTEN ACCEPTANCE FROM THE CITY OF HENDERSONVILLE PRIOR TO ACTIVATION OF THE SYSTEM. WATER SERVICE WILL NOT BE PROVIDED UNTIL WRITTEN ACCEPTANCE OF THE SYSTEM IS ISSUED BY THE CITY. 11. THE ENGINEER SHALL SUPPLY THE CITY WITH FINAL AS -BUILT DRAWINGS AND COMPLETE ALL PROJECT CLOSE OUT REQUIREMENTS. THE STANDARD WATER DETAILS ARE FOR THE SOLE USE OF PROJECTS DIRECTLY FOR, OR THOSE PROJECTS IN WHICH OWNERSHIP WILL BE TRANSFERRED TO THE CITY OF HENDERSONVILLE. THESE TYPICALS ARE INTENDED TO SHOW THE CITY OF HENDERSONVILLE'S EXPECTATIONS FOR THE GENERAL LAYOUT, ARRANGEMENT, AND THE QUALITY OF EQUIPMENT AND MATERIALS FOR WATER DISTRIBUTION SYSTEM ITEMS AND THEIR RELATED APPURTENANCES. IT REMAINS THE SOLE RESPONSIBILITY OF THE ENGINEER IN RESPONSIBLE CHARGE (ERC) OF EACH APPLICATION TO DETERMINE, DESIGN TO, AND CERTIFY TO THE DESIGN PARAMETERS FOR EACH INSTALLATION. THE ERC MUST ALSO ENSURE THE DESIGN COMPLIES WITH THE MINIMUM DESIGN CRITERIA OF NC DIVISION OF ENVIRONMENTAL QUALITY AND ALL LOCAL AND STATE LAWS AND REGULATIONS. DATE: 03/14/2019 WD DWG. NO. 1 ISCALE: NOT TO SCALE I City of Hendersonville Engineering Department 305 Williams Street Hendersonville, NC 28792 (828) 697-3000 (office) www.cityofhendersonville.org WATER DETAILS GENERAL NOTES NO. I DATE I BY REVISION DESCRIPTION Z J NO I..L U /1 W O Z ROM J D z D O 0 z O N) w LL] 0 z LL] L N U) Lo W_ o W SLI U IY ' cn zo7 z W o 0 J_ (� U LL -0_ SHEET G-004 = M 0) < CD W o8 NN m ~ W Z =) � Iz 0 1 z m z z w M w Q w Q � 0 0 U 0 /1 W O Z ROM J D z D O 0 z O N) w LL] 0 z LL] L N U) Lo W_ o W SLI U IY ' cn zo7 z W o 0 J_ (� U LL -0_ SHEET G-004 �I �I ZONING BOUNDARY LINE 'I I 3 I 0 GRAPHIC SCALE PLAN 40 80 160 240 I INCH = 80 FEET 'I I I \/0000 ODOM, MARSHA A SANITARY SEWER MANHOLE I I \ PIN: 9650079059 TOP EL: 2086.45 1/2" OTIPF I DB: 1032 PG: 81 I EXISTING GRAVEL DRIVE TO \ BUSH, RONALD E; BUSH, JOYCE R \ I I REMAIN (TYP.) SINCLAIR, FROSTY A; FROSTY A SINCLAIR \ BENNETT, LARRY; THE LARRY AUSTIN, BRUCE; AUSTIN, THERESA \ PIN: 9650174702 ADAMS, BRYAN; ADAMS, F—N DB:534 PG:389 REVOCABLE TRUST \ BENNETT LIVING TRUST PIN: 9650173407 STEFANIEPIN: 9650068876 PIN: 9650171258 DB: 1586 PG: 673 PIN: 9650176986 EXISTING 50' WIDE DB:1431 PG:204 DB: 3259 PG:154 DB: 1616 PG: 518 ^---��ON LINE I EXISTING 50' WIDE \ / A HIGH PRESSURE I �' I �" GAS EASEMENT \ \ I HIGH PRESSURE I GAS EASEMENT DIT' OTIPF _--___- _ 1/ " RBF / OW @/i TRBF 1/2" OTIPF 1}2/�'�OTIPF EXISTING WATER LINE I I BLUE pAJ __ -- --- 368.30' 1 361.91' 15.75' .60' — T _ UM 9 - 6 21 -- — I.E.: 2 89 1 _ — — - -- ------ — — 396.76 2 — - — - _ - — — - — — — —— , cn „ — 29 — — — —---------� -- _i=- U-- U--� U—_S�§39t�U----r P S36 �I W ---� -- ---> --- ---- S36 3fi2�"k1C----- S37°15'29"W S3 56 \ J — — — _ - _ /� ' i' �-- �' y � 25 54 _ -/--------- _�+ ----- „W 135'31'35"W-- t�+' \ - - ) 1 / - - - _ FBF /i Ft EXISTING 15" RCP TO I. 1. 4' ' __ / -2105-I I \ \ \\\\`� �� LOT _ \==____� = -- --_ �_ \ / := ^ NDSCAPI OTIPF o \ \ \ RASMUSSEN, PHILIP M; \ / / / 2,25_— -- ' REMAIN (TYP.) I RA A r \ \ ------ ' ' - / / I LE.:, 2' --- 'F` I —x — � SMUSSEN, PRISCILLA _ 3 _ \------------------ - 1 �_� - _ /. I� �---7 - - - ----------------------------------LOT 1/�-/--1----� --�� PIN: 9650161982 I �,� _ \� ` ` --- �j%% �''�//i'% 212° �, : ^\\ /'' \\ /% ' 00o, �' � / D6:1370 PG: 471 �, _ =/ // \ �� 0 I I I / ���, SPANO & ASSOCIATES / I m`� �'� `�� LOT 3 IZ II,:> HAYWOOD, LLC -- / Z - /�s_ N w v 01 PIN: 9650069662 / 212 \, SPANO &ASSOCIATES / ——= — HAYWOOD LLC-- `DB:3278 PG:574 / Z — ---- / ----- — --- PIN: 9650175207 __---___--- 2120-7— o�_ DB: 3278_ PG: 574 _ —2115— ♦ SANITARY SEWER MANHOLE I I I I Iz: 1 I ` I \, I. < / m - - - - - - - _ _ _ - _ _ - - - _ ♦ �iI / -'/ \ TOP EL: 2084.72' c� i \ I \ \ I / 2115- A,- 12" PVC IN (SE) I.E.: 2077.53' sI \ EXISTING PROPERTY LINE,12" PVC OUT (NW) I.E.: 2077.49' ?y\\\� \ \ \ \ � \ 1---------- /\ TROUT WATERSNEAR CENTERLINE OF \ �' -' BUFFER (TYP.) EXISTING 16' \�_ \ I =R_ _---_ .-I I A I \\\\ f 1/2" RRFZi - ,�\ii�WIDE ROADWAY 1 �� "� EXISTING 16 WIDE ROADWAY \ _ =2,1D= �— - '\___ \021- - - --M021- - - - -M021-M\ \ \ / /it ASPHALT - / TO R MAIN BLUE °\ DRm 'Zoos' �r�_---------��° ==rI GAgSTUe \� '' �\II/////��fLE\2,oLs4 --- -- �' --1 /�///r/ I I^ f —�iG 30 PERENNIAL ♦ I o_ /Ac I I t = _ _ -, _ ___ . s ____L °T_ STREAM BUFFER CONSERVING CAROLINA ♦ I I I �, \ _ _ /— ����� / \ —�— \" a PIN: 9650059838 ♦ F I I I 1 \` \ \I ) LOT 6 - - _ 1 l cll I �� ' _— — °S ��i// — �y�\ (TYP.) ♦ I I SPANO & ASSOCIATES., DB: 28 PG: 552 � r� � I I ) — � ' i 1 TOP 18" CPP , -2105 rn d i \ I I I HAYWOOD, LLC -, /i /) Y/10 I INI� I \ \ '°° l I 1 PIN: 9650161443 ��� �_ s"ti�� / / : '<�'�_-z 1 Top FI �� a 65' ///// / - i I I \ \ \ \ \ EXISTING CPP- TO �!� =--- �— \ / EXISTING STREAM CENTERLINE — _ L \ DB: 3278 PG: 574 _ EL: 2,,.s3' /� —� = \\ $� SANITARY SEWER MANHOLE I I \ \\ ` \ I I ( ) °— - ''� \'1 05 OF UNNAMED TRIBUTARY TO k*YD \ _� \ \ ✓�/Ir — REMAIN TYP. /, -- ,�, / /,�/ `� —� \\rr.\\\l �N��' �� TOP EL: 2088.81' F \ \ \ J// - J- / i / \\ \\ \ \ / ��' 12" PVC IN SE I.E.: 2078.14') s I I I __- - ��\ \ \ _ %� J - - - �, ;W /i j'1 :i / / / %� / / / �' tR ' /\ + i O 1 \\ — _ .— ___ _ / — ,� MILLS CREEK (FLOWING WEST) 12" PVC OUT (NW) I.E.: 2077.93' ti / O I I /-_ - x,`\�� = - '�µ�i� - - - - / v _' i I it - ^ \ J// /�(f 11 i i /' ' ,''i - - / // f ✓ i / OOD 1 (� I I I' f % \ - I I.E. HAYVV NOL DRIVc I p r/�i ' ' - _ � N _�i �'� /SANITARY SEWER MANHOLE K RE)W1= /SR -2044 IIII TOP EL: 2118.74' SANITARY SEWER MANHOLE TOP EL: 2089.66''° I ' i - / / RDFUE P 12" PVC IN 8.72' Q 12" PVC OUT (NW) I.E.: 2078.72' I o �70.96' OUCRETEv//I % EXISTING LOT INTERIOR PR OPERTY LINE EXISTING � - LOT4 TO BE SUBDIVIDED (TYP.)P.) X _=RIGHT—OF—WAY (TYQ SPANO & ASSOCIATES / H AYWOOD, LLC EXISTING 15" CPP TO BE /I I I r �/PIN: IN: I 96/50165805 I D:3278 PG:574 ,j i EXISTING DELINEATED LINEAR WETLAND (TYP.)REMOVED -+/, / , EL: 2091.3 1 / / I I I/— —' / III I I /// / (/ \ i-ROJF EL: 2091.49' INV. 2086.16 III I ( / INV EL: 2086.33' / / / I / / / / / O� _ - - - - - -- DRIVE \ EXISTING ASPHALT I . � �/It� =' / �,/ ,—III I Wl ,/ /� ,`�11 /— �_--- i i IJ/r��; �.o%'� ' ° DRIVE TO BE II'�r - I / / \\ , / / / I I 5\ DEMOLISHED I 'I LOT 7 -� ► �� ,� LOT 5 I SPANO & ASSOCIATES 1I �, � I SPANO & ASSOCIATES �� / I / / 4ss P SANITARY SEWER MANHOLE I I I HAYWOOD, LLC ,/ / / (7; \ HAYWOOD, LLC TOP EL: 2087.59' / 12" PVC IN (SE) I.E.: 2079.34' ss I PIN: 9650163229_/ PIN: 9650164528 DB:3278 PG:574 --�� 12" PVC OUT (NW) I.E.: 2079.16' I I �\ — I / s�RBF y I , v / \ DB: 3278 PG: 574 � SANITARY 093.61' TOPEL2 19W9R MANHOL CONSERVING CAROLINA I I 's•. / r — — / // / \ \ I/ / ^' / / PIN: 9650059838 1 1 18 48"E / / / / I I I I I I tih lr POST FOUND DB: 28 PG: 552I I III \ 34 6 ��— ' / // /�/1� <n o I I.E.: 203\' POST FOUND EXISTING PROPERTY LINE (TYP.) EXISTING 100' I RIGHT—OF—WAY (TYP.) o o / / 1 I I LOT 8 / / / / POST FOUND 0 SPANO & ASSOCIATES k i // ^'. HENDERSON CO. BOARD OF PUBLIC I.E.: 2093146'-'-I I HAYWOOD, LLC ON LVE syy SCHOOLS PIN: 9650164056 �� ��° PIN: 9650262638 I I o/ RBF TOP EL: 2110.75 MANHOLE DB: 824 PG: 213 EXISTING SANITARY I I I � ! DB: 3278 PG: 574 ' SEWER LOCATION I.E.: 209t.18a, ,',' n r / \ i / — — - T- T / � . FOUN lI 1 I I // 2� / ^w I I 5, '; �IF //=\/� ( I I I I ► / ���� j �24" CMP EXISTING 15 CPP CMN LINE 2224 TO REMAIN (TYP.) pBFr I.E.: 2109.39' I I I M`Ip /R POST FOVrt UND , 1 i o SANITARY SEWER MANHOLN POST FOUNt� TOP EL: 2088.70'--------(s g I o N-- s2,y II \ 011�1 I 1/2" RBF I 1P AP r I I ;N\ 7'49'49"� SANITARY SEWER MANHOLE W - - - - - W - - - - - W 3 1° TOP EL: 2108.95' —_M 41 EXISTING DELINEATED WETLAND (TYP.) _ T I I M M_ - i I I — I I I I I 3 I I NOTE: 1. THE 30' PERENNIAL STREAM & 25' TROUT WATERS BUFFER WIDTHS SHOWN ARE MEASURED HORIZONTALLY FROM THE TOP OF STREAM BANK. REVISION DESCRIPTION � W011 � W J U 0 w 0 U 2 V) d w W >0 Q U 00 W N } U) � rx w �= 06 O M--4 U) o U) H N U) Q N 0U c Uo (/) 0 U m U) x 0 � a 006 Wo U) r� z o °O N v 1 Z C) �Z LLJ v1�a U) = Q w O J 00 O -3 0 0 0 w U LL — U W¢ W� W � o W� 3: U � W J O w 0 J 2 z 0< � J Z Z 0 01-- 0 1U J (D0 Z 2i Lu U) Q X oes W SHEET U Q z Z J O J J 2 V) d 0. >0 Q U 00 W N } U) Q W �= 06 O Z U) > � U) H [-.- U) Q Z 0U c Uo (/) 0 U m U) Z OQ z O 006 U) �0w z o Z C) �Z LLJ G U) = z 0< � J Z Z 0 01-- 0 1U J (D0 Z 2i Lu U) Q X oes W SHEET 2 x W M Q W CD N } = W O a, 06 w Z m 0 > � > � U � c p z m z� Q� .o z w 2 CD 0 z o G Q w Q w O J 00 O -3 0 0 0 0 U LL — U z 0< � J Z Z 0 01-- 0 1U J (D0 Z 2i Lu U) Q X oes W SHEET ZONING BOUNDARY LINE ' PLAN 80 0 40 80 GRAPHIC SCALE 160 240 1 INCH = 80 FEET 00 ODOM, MARSHA A PIN: 9650079059 \ DB: 1032 PG: 81 I I \ BUSH, RONALD E; BUSH, JOYCE R SINCLAIR, FROSTY A; FROSTY A SINCLAIR BENNETT, LARRY; THE LARRY AUSTIN, BRUCE; AUSTIN, THERESA \ PIN: 9650174702 ADAMS, BRYAN; ADAMS, I PROPOSED LARGE, DECIDUOUS REVOCABLE TRUST BENNETT LIVING TRUST PIN: 9650173407 DB. 534 PG. 389 \ STEFANIE PIN: 9650068876 PIN: 9650171258 DB: 1586 PG: 673 PIN: 9650176986 / I I TREE, 24 STREET TREES DB: 1431 PG: 204 DB: ��sa �d DB: 1616 PG: 518 PROPOSED B2 BUFFER I REQUIRED ALONG EXISTING EXISTNOT IINCLUDEDNG LOT ISN ' \ \ ' HAYWOOD PARK DR. I EXISTING 50 WIDE I \ THIS P OJECT HIGH PRESSURE INSIDE 50' SETBACK I I SEE PLANTING SCHEDULEZ GAS EASEMENT ------ ------------------------------ ------------- -- --_---- _ LOT 2 GRAVEL DRI I I I I I RASMUSSEN, PHILIP M; I \ \ f I I \ \ \------------------------- I RASMUSSEN, PRISCILLA A-I--------------------------�----------------------------------------- N --- --- ---- - I------------I---I----------------r---------------7- PIN: 9650161982 I I \ \ �= \ \ \ 1.11 AC N I 1 \ 2() 48187.2 SF I� I I I III I DB: 1370 PG: 471 I \ \ \ C9 I I 0.69 AC I I I \ \ � 0.95 AC \ \ FFE: 2118 Z 29969.7, SF _ I I 1 I \ \ \ (�) 41503.1 SF IZ I FFE: 2109 I I r --- AC I 1 0.59 AC FFE: 2121 \ \ \ /� IN I I I I 25824.7 SF I I 25809.0 11 I APPROXIMATE 1 �% \ \ \ - N I 1 I I 'FFE• 2111 I 1 i FFE: 2111 1 , 50' SETBACK FROM ROW LINE TYP. EXISTING 16' I WIDE ROADWAY I 20)yI c � TO R MAIN II CONSERVING CAROLINA ` I PIN: 9650059838 o DB:28 PG:552 EXISTING 10' X 70' I SITE TRIANGLE (TYP.) - - HAYWOOD KNOLLS �o►a� DR/VE I EXISTING 60' /I' RIGHT-OF-WAY NI I (TYP.) I i PROPOSED B2 BUFFER 0 0 INSIDE 50' SETBACK I I I 50' SETBACK FROM I ROW LINE (TYP.) o I I CONSERVING CAROLINA PIN: 9650059838 I DB:28 PG:552 I M 0 I EXISTING 100 I RIGHT-OF-WAY I (TYP.) I A co I I PROPOSED 10'X70' I i SITE TRIANGLE (TYP.)cn I i I i o I � I � PROPOSED B2 BUFFER I i INSIDE 50' SETBACK I I i 36' i I I 1 I I EXISTING 45 1I II 1III ii .AC 03 1 I I 1 2 43.0 SF \ \ I I FFE: 2115 III I I I I--- ' I (TYP.) --top - - - - - - MOM - ASPHALT DR -- -MON-- -M 21- m `_'•-' \ HAYWOOD PARK DR - - - - -' _ _ - - - --'----- - -� � - --- '- PROPOSED 12' WIDE r ' -� _ yNd� SHARED DRIVEWAY i -r- ---� �- --� r- i �I- 0.64 AC I I i I I I 1 I 1 I 1 1 28090.8 SF I I I � III III 1 I _, III 9 FFE: 2103; �� ,/ / 4 1 Ili i j III --i III I i I I ; i I I /i, J 1- -- `\\ I � I I OI 1 , 1 I , , I I ,, ,•.� �`. ., I ' 86 A I I ( I 1 I Oi 1 1 10 1 1 0.64 ACI I 1 / 1--------------i I 0.86 AC I I i I 1 i 1 1 I I I 1 /.' .�' ---- __ •� 37485.8 SF I I I------ I I------- I I 28088.2 SF I -f � , ' - - - - - _ ).\ I I I I I I I 0.64 AC FFE: 2103 i�j /' �' _; /� - - - - - /� �\ OPEN SPACE FFE: 2102 0.66 AC I i I '`: ' ./� , / 1 I 0.59 AC 1 I 1 27768.2 SF I - - - /' ,' &_::- - I I 28936 2 SF - - ------ 1 ./� ; I I� � I COMMON AREP I----- I I FFE: 2103 I I I 25563.2 SF I I 1 FFE: 2103 1 _. 1 FFE: 2103 "r PROPOSED 30' I 1 I \ ; / ' I I ► I L- L' I L ,, \l__a_;'�' /% DRIVEWAY EASEMENT �_ 1.12 AC Lit-__=i� ► 4- 10 (TYP.) 1 I I 1 _ -____- \\\ \ 15 48777.7 SF J _J (__ ��� _ i / /� \ FFE: 2121 0.66 AC I -------_---- ------ -J I -PROPOSED 35�\ 14 28725.2 SFJ FFE: 2109 CUL-DE-SAC\ RADIUS\ 10' (TYP.) 0.57 AC 13 0.70 AC I I j __I I 0.68 AC \ \ 24789.6 SF`s 30301.3 SIF I I I I 29784.6 SF \ \ FFE: 2110 I FFE: 2094 I 0.60 AC I I FFE: 2104 \ \ \ i f ► ► FFE 42099 I I I f \ \> / PROPOSED SINGLE FAMILY UNIT R 0 L► I I I ► I ► 12 \ \ \ fv "/ (70'X40' PAD SIZE) (TYP.) 14 LA WI D T 11 I ► \` \ \\ / / 15' (TYP SrhAs 34 _ PROPOSED 12' WIDE 3R 2 ------- ®- / DRIVEWAY (TYP.) 7,12' LANE W PTH I j r------sY-d�_ �- -»i / PROPOSED LARGE DECIDUOUS 'R2� TREE; 27 STREET TREES Q ►I► / / REQUIRED ALONG PROPOSED I 1.09 AC I ► �' HAYWOOD CROSSING DRIVE. I 47355.1 SF I ' SEE PLANTING SCHEDULE I FFE: 2096 I � 48551.7 SF / // I I 16 I I FFE: 2102/// HENDERSON CO. BOARD OF PUBLIC I III ;_ / PROPOSED 100' CENTERLINE SCHOOLS 17 PIN: 9650262638 CURVE RADIUS DB: 824 PG: 213 I I PROPOSED 16' WIDE ROADWAY (PRIVATE); i III /moi I / I � TO BE NAMED "HAYWOOD CROSSING DRIVE" PROPOSED PROPERTY LINE (TYP.) L_ �' PROPOSED SETBACK LINE (TYP.) PLANTING SCHEDULE SYM. I QTY. BOTANICAL NAME ICOMMON NAME SIZE I *CALIPER HEIGHT TREES BN 22 Betula nigra River Birch (3 Stem) B&B 2" MIN. 12' Min. MA 16 Magnolia acuminatae Cucumber Tree B&B 2" MIN. 12' Min. BN 13 Acer saccharum Suqar Maple B&B 2" MIN. 12' Min. NO. INO. I DATE I BY REVISION DESCRIPTION � W Q Z U� 0 OJ J _ U) M W z >0 < w C) wC) 22! >O w = Q U= O ISI U) o N V J U � Q N 0 U Up O U M U) x O � a 006 0 o u, z a0000 N Q Z U _ � Z �Za W = 0 0 U 1 00 4 > w z W¢ cn WW z� F11 Y --i v] � o W� � 3: J W O w 0 Z Q a - Lu I- U) Q 75 SHEET C-101 U Q Z OJ J _ U) M >0 < U C) wC) 22! >O m = Q U= O Z U) > V J U � Q Z 0 U Up O U M U) Z OQ z O 006 0 U) u, z O OfW Q Z p _ � Z LLJ W = Z Q a - Lu I- U) Q 75 SHEET C-101 2 _ U) co < w wC) 22! C) w m = 6 > > U 0 Z DO ZF_: Q,t 7q z w LD 0 LD u, z zoo M p Q 0 w o Q w w O wo J ap L? 0 0 0 0 U 1 00 4 Z Q a - Lu I- U) Q 75 SHEET C-101 I w— J I i PLAN I 80 0 40 80 160 240 I I GRAPHIC SCALE 1 INCH = 80 FEET I I I I \3 ODOM, MARSHA A I \ PIN: 9650079059 I \ DB: 1032 PG: 81 PROPOSED I I PROPERTY LINE SINCLAIR, FROSTY A; FROSTY A SINCLAIR \ BENNETT, LARRY; THE LARRY ss 3 REVOCABLE TRUST \ BENNETT LIVING TRUST (TYP.) PIN: 9650068876 PIN: 9650171258 DB: 1431 PG: 204 \ DB: 3259 PG: 154 000 —"`— EXISTING FIRE PROPOSED CONNECTION I IN6ae;�e°n° HYDRANT TYP. \ PROPOSED 6" DIP WATER IEL 209654 (TYP-) TO EXISTING 6 DIP \ I I I I YPAINT LINE A — — WATER LINE (TYP.)— — (SEE SHEET C— I I II ---1-- ------ �---- = ---- -7 rte_ _ I III �,__ LOT 2 I I� `L__;�+y€-�o� — I \\\\ \�� ��\ RASMUSSEN, PHILIP M; I I m /- _ RASMUSSEN, PRISCILLA A 2j39 -- ��-i�lll(jf--r ' ------ - -r------------_+-=J ��-�-- --- --C PIN: 9650161982 I Z /I�-- -- -- ---� EXISTING 6" DIP �I I IIII II 0.69 AC DB: 1370 PG: 471 m II I IIII�I►III\1I�►1i\IIlI1II \I ��l 99-69SWATER LINE (TYP.); 059 0.5/9 AC /D _ - —_ - — _ - - 25so sTO REMAIN IN 2 8.24. SF Z __I till AFTER _ f 18 ONSTRUCTION 2 3 m 3543_0SF - ss 2110 �y II I\��� \l I`_ - �- o - PROF OSED CONNECTION I — co `\ T' PKN0702427UTC I �I I '� i— — —MON — — — — —MOa —I� — M .21 1 A or ASPHALT Dr2 ®ce I r*1 TO EXISTING 6 DIP 0 _ - A WATER LINE (TYP.) I II— I -- — — — --- -- — — _ — I 2110 \ CONSERVING CAROLINA\_ - PIN: 9650059838I f DB: 28 PG: 552 i — —pD KN i?oLW_— �fR-2044 EXISTING 24" WATER LINE (TYP.) �� PROPOSED 8 DIP I I u''I 13 �' �' 0.70 AC 1111 / 30301.3 SF/ // u.nrs vu / L4/zsa.n tri _ —L // '� 29784.6 SF0.60 / ti WATER LINE "B' I �` ' / < (SEE SHEET C-112) I I I I gill 0 Imo/ ► / 10 26174.1 SF C) f ► I — U � z co o /// 1 ZU w a s o L;. (Dz O � x w � � w H � o z I c� Q / / CONSERVING CAROLINA O U I I _ PIN: 9650059838 m p I I I o Q DB:28 PG:552 � a 0� -4 z o I o) / I I I I U I « / / I ►� I // ' PROPOSED 2" SDR -21 WATER 1.0 Ac �' /� — �I �I \ I // LINE "B" (SEE SHEET C-112) I p l I I II x 47 5.1 FI / .11 C // / N I I Q II II I I I I �� 551 IS I 0 011, I I 1 11111 16 I I 1 1 al I l I / / I I 110\1 — ^ / I �I _ _ '\j PROPOSED FIRE HYDRANT W/ 6" I = I �,_—//' GATE VALVE & BOX (TYP.) I I / / / / I I I II, o 11Z o PROPOSED No,�WATER SER VICE EE.95147.12 '20830 (TYP.) ---w-----w r� —MT__��M� �M I -- I I I I I I I I PROPOSED SINGLE—FAMILY LOT (TYP.) HENDERSON CO. BOARD OF PUBLIC SCHOOLS PIN: 9650262638 DB: 824 PG: 213 \ AUSTIN, BRUCE; AUSTIN, THERESA \ PIN: 9650173407 DB: 1586 PG: 673 PROPOSED 2" SDR -21 to 99 \ BUSH, RONALD E; BUSH, JOYCE R PIN: 9650174702 D13:534 PG:389 PVC WATER LINE A \ (SEE SHEET C-111) _____------ / o // /i-2125__—_ PROPOSED 30' WIDE DRIVEWAY EASEMENT (TYP.) PROPOSED 12' WIDE SHARED DRIVE (TYP.) PROPOSED FIRE HYDRANT W/ 6" GATE VALVE & BOX (TYP.) m�=W_ v ADAMS, BRYAN; ADAMS, ST / PIN: 96501765017 6986 DB: 1616 PG: 518 / / / / REVISION DESCRIPTION 3: � W J O w 0 J < 0 (/1 Q 0 oN p U � z co o 06 ZU w a W L;. (Dz O � x w � � w H � o z Z�_: c� Q (_)o 00 N O U o a z Z o m p w o Q O � a 0� z o 00 N c/)= V1 U � z w � x W¢ W� W � o Wkn kn 3: � W J O w 0 J < z J LU w OQ SHEET Q z ZJ Q J J < 0 (/1 Q 0 oN p U w w co o 06 Z m~ W L;. (Dz O zc/) � � w p� � Q z Z�_: Q (_)o o O U o a z Z o m p w o Q U) �o� w o c J 06 0� z w 0 c/)= z J LU w OQ SHEET m M < 0 oN Q w w co o 06 Z m~ W L;. U L � � p� Z m Z�_: Q Z uj CD v� p CD u) z Z o m p Q w o Q cn w O w o c J 06 z J LU w OQ SHEET 0 Lu Q 0 0 0 N C, a co 0 0 T W 0 N C 3 0 15 7o M 0 m J PLANkn \ 50 0 25 50 100 150 ---------------- rW GRAPHIC SCALE I INCH = 50 FEET PROF�OS D WAT R' 2'25 =--""- ' �� PROPOSED'SINGLE FAMILY ---- l''tiNb ____------�;__= — SERVICE (TYP. — \, / N , �`� �` \� APPROXIMATE END OF m UNIT (70'X40' PAD SIZE) TYP. ��'� / _ _ --- ------ —= "_' �r �- - I --I �) \� ---�---- ------ �---�- EXISTING 6" DIP WATER LINE; CONTRACTOR TO 3° - \ ,_ f/ y --------------- --------- ��-_ - 2130 — — ' /' �' — 1.11 AC FIELD VERIFY (TYP.) _ STA 3+80 WATER LINE "A$' - , 2O 48187.2 SF -- 2120 0.95 AC FFE: 2118 �x ` _ 2115 — - SFS, Z PROPOSED FIRE HYDRANT -- -' �,� ------ -- — _— J ,41503.1 0.59 AC -' �' 25809.0 SF Z Z (FH #1) W/ 6"x6" TEE ,25 „ AND 6 GATE VALVE------- ---- ---------- - - - - - - - �� ;,_FFE: 2121 --� ,— _ '___- ` \ - �;/// /;i `� 00 %I -- -- - _, / -, u -FFE 2111 ' / "' ---- BOX-- ---- -- -- - _ ^� ------__-_-_ -- --- -- �— _ — k _____ ---- / -_� "A" ������� i w /' <Z Luj__ __ _- -- STA 8+44 WATER LINE -PROPOSED 3 __-1.00 PROPOSED 6 DIP --- - 18 AC =_____— _ -- == ---- o% yam`---�� SF-===_—_____�____—__--- kp / 7 BLOWOFF VALVE / (TYP.) Z I --I iWATER _—_ _--- LINE »A„ —_------� _____ _ —_ __ --=43543.0 _—FFE_2115—_---__/,/ (WV #3) a o \ / STA 0+05 LINE ens (TYP.)---___ "A" - - - ==-��------��5-00 �� -,_ �co --- 0—Oor/\\/ WATER __ ___�__ __ `� PROPOSED 6 GATE VALVE (WV #1— 210 -r __- (TYP.)00 -_ _____ / /' _ __-_ � o-\ //' \\ \\, ;; , \ _, F/ \ _,_, PROPOSED �• 20 WATER Z \ G co �= \ \ \ — _/, -_ -- 2110 — — -_--- ��aO�f-s• ---Moa-----M _-- r--- --- '- �\ — — — — — — a —Moa —__ ��J — �J� _ o� S \\%'�� viii^�ASEMENT \ 6+ 00 (TYP.) C7 ¢ 0 — 2110. _ --_-- —_—' -- -- `� — ®CB __—' �i ♦ \ 2to — w \ �\ -- — ---- w ---w —_--- — 0 --w 1+00 __ 2+00 I -- —�3X — -211 - \ \� ,-�� OP6St1S EW�R \ \ 1 _--' /i,'��/�________�;—�_==SERVICE (TYP.) _ SEE SEWER PLANS) ` / Ste' �� \\ SIr / \ I ,///���// ' I I �__ �/ /�� ii v / �� / LLQ i �� o. A �� /o-� , _\ -_ -__ _ PROPOSED OR WATER / / !- / / -J /�-61STIN FIRE HYDRANT - _- ��-' �� �'�'I 90 ,' ��� ' /_-PIPE ,'%'� ---_ - —_ // (TYP.) / I �� z \ (TYP.); TO COORDINAT - _-- �R / �1�� —2 - _ ---;;; ' % ��` �\=-� SEE STORMWATER AND \ 9 � � S � �/ !/ ,;„� ��� - � \ LL �J Q \ WITH COH WATER FOR _ GRADING PLAN) \ \ IN L GRA TMEN 5 2105 ___— _ 8 =�� _ //// %'� —— 2,05 ---� '''�—'� 00 STA 4+69 WATER LINE "A» ul / �— '� ' ��'-- �Op-*g”-- /,//,%/—'�`� —�',— ;,—'' PROPOSED AIR RELEASE �' V Z N I_ I _ 2100 �= ii " -'' 0.64 ' " � -911.8,3 FFE: 2103 \ - ,// / �' ^`�-- ,- = VALVE AT ACTUAL HIGH -' �X' J IIJI -_ _ - \ -, 280 8.2 SF co \ _/// %Ji/,- , �� - - --' _ _ --' _ POINT (TYP.) (WV #2) /;' J J 0.66 AC SF; -A — 25563.2 0.64 AC 0.59 0.59 AC ���='27768.2 SF SF FFE: 2103_ c0 / / / ' �� ;; / ` �S� �� i//� I PROPOSED SEWER LINE' "28936.2 — — _ _ �'�� FFE: 2103 0 �� rfi—/_ \ \/ / n // // (TYP.) ----� `� `�� ` /' �1 -, , —��� 2103 FFE 2103' �\ -= ____ ' ;-------- %';� I Cc �� N S \� s �� // �� /�� \ \ / y\ `_/l // _— i' \,\ \ 3� //i ' SEE SEWER PLAN) -' , ,—__— \ ��� / / _�\ \`� \_e D O c 34.95 LF 8" DIP CO SANITARY SEWER MANHOLE TOP EL: 2118.74' VJ T O Z � " NO. DATE BY REVISION DESCRIPTION U) Q Z WATER LINE A PROFILE 0- "= 0 0 SCALE- HORIZ. 1 50' V U VERT. 1"= 5' Q CU) W Q> J 0 Q 0 2125 z J > WQ z 2125 0 06 U) x w— O m J J \ S W a 3 z 0 m a> w N� w3 ROPOSED 2" SDR -21 <0 Z Q 0 o Q; w J a PVC WATER LINE; 't 0 Q = 2120 a - - a - -1 Z w of 3 MIN COVER + 2120 - U) LZLJ _" z� 0 J> z uJ > Q REQUIRED 00 0 2 N -w Q PROPOSED 6" DIP WATE J~ te r Q J ~ 0' �xixa" LINE (TYP.) QC°"� co vwi� ca 2115 (00_3 CO 3' MIN COVER REQUIRED 3 a a _ 2115 0 oN Q w w - 00 ~ 0O W 00 D DD HIxH / - w °° Lu w U 0 OWH +N + U O a_ +NNN �`� O 00 NdQ o � Z m Z co rn 0 0 a_ z -Q 0- PROPOSED GRADE (TYP. Q 0 0 0 Iii C7 p C� o� Q O z Ngo N� H �� ��aa / 00 Q w Q w o �a q 2110 2110 2105 2105 LL) J L1J EXISTING GRADE (TYP.) Z ROPOSED 18" HDPE LL PIPE; Q J MIN 18" VERTICAL SEPARATION —1+00 0+00 1+00 2+00 3+00 4+00 5+00 REQUIRED 7+00 8+00 9+00 0— w APPROXIMATE APPROXIMATE LOCATOIN OF PROPOSED 18" HDPE PIPE; Z ~ Q EXISTING 18" HDPE PIPE; MIN 18" VERTICAL Q MIN 18" VERTICAL SEPARATION REQUIRED J SEPERATION REQUIRED SHEET Ir 0 W Q 0 0 0 0 0 3 a 0 W 0 N 0 2 0 0 m J I m y o I_, o ASPHALT� \ 3 \ W I BLUE I I ,�� PAINT p I _I �_I 21100 6 W \ 1 - � PLAN W � I ; - - - ---- - w STA 0+00 WATER LINE "B" so 0 2s so ioo iso L, C—' PROPOSED WATER LINE "B" TO CONNECT TO EXISTINGI II I /// \ \ \ \\ \ /�- ,, _____ \\ GRAPHIC SCALE 1 INCH = 50 FEET J �, Qr 6" DIP WATER LINE W/ 8" TAPPING SLEEVE AND VALVE 2110 4--- I I II II p I +I Il \\ \ I , , 5 2105 _ ` N I N I L\ P D\ \ I I \ 0.86 AC \ 11( \\ 2100 0 o —Rew—,I SANITARY I \ 37485.8 SF\ I SEWER MANHOLE TOP EL: 2088.81' 12' PVC IN (SE) LE.: 2078.14', ss J I I I \ — / I I I — -FFE: 2102 \\ 0.66 AC/ \------- \\ I `------ _ 0.59 AC Z _ 12' PVC OUT (NW) I.E.: 2077.93' � I / I o \ \y0 --_ 36.2 SF' � 1 � ,9 `` -289 / I I I s /----�— \ ` I\------ J— 25563.2 SF t------' w '_ --4I I __ --- ---_J'"` I - S` \__ — —=-_ -FFE' 03 2103 �\ ---_ --- HAY I A o I' ` __ co 1 - ! \\ S iso _ —�--R----__� Op KNO 1 I _ I _ I s I �+ r �/ /--_�_ ; - ;� � � � �`\ \\ STA 10+75 WATER LINE »B» _DRIVE — � - SANITARY SEWER MANHOLE— TOP EL: 2089.66' 's >�fi(/ E _ _ NI _'_ S i111�1 / ,� ,\___%% \ / co / / // // -PROPOSED AIR RELEASE VALVE AT ACTUAL HIGH _ , POINT (TYP.) (WV #5) �' /' � // / , / 1.12 AC 12" PVC IN SE I.E.: 2078.72, ( ) s 12" PVC OUT NW I.E.: 2078.72' ( ) S f I PAINT I , _ / _ _ \ _ =—= = __— — — = __ _ \ I 1 Td2 — I I )) ---- --_=Q--=--- — i'� / / I �—__:_--__ \ \ i' ' /% // �� I P D = _ _ — - \\ / I� _ I I►II\ � / / / 15 \ \ / / I / i i / / / \ � / I // i/ / h // /' /2121.-- / / I / 48777.7 SF / ,FFE: 2121 ^ y I 1 I 100 r I � PROPOSED SEWER LINE I PROPOSED TYP.SEE SEWER PLAEXISTING ROP/O�SED SEWER 0 .66 AC 14 28725.2 §F IJJ I I:;i=,� / o/ SERVICE (TYP.) ,o / w� , I RIGHT-OF-WAY (TYP.) I I A I �� I O / r / 0 " / / STA 7+54 WATER LINE "B" _� //// �� / T / / /'\ / / / / (SEE SEWER PLANS / / �-� ��� / / F E: 2109 / ' / / �\ _\ � / / , �/ / ////�// / / ' / / i // o ` II I I I + PROPOSED FIRE HYDRANT // (FH #2) W/ 8X6 TEE AND/ P OPOSED WATER \ / / ' - - - - - - ' '" » I ROOF EL: 2091.30-,--7) 6" GATE VALVE & BOX / (TYP.) ,/ (TYP.) I " G'r---�_ ' ' �' SERVICE TYP. / '�\ I ( ) _ - - -/ / I 13 - / I I ► I ► ► , / / / '�/LL ,/� ��/�%<\ '� PROPOSED SINGLE FAMILY w O PROPOSED 8 DIP INV. EL: 2086.14 I li(I I _ I 1 I I / / / \ UNIT (70'X40' PAD SIZE) TYP. WATER LINE "B" o ,,) lr 1 1 i i ROOF EL: 2091(49' I Jill lI �/ INV. EL: 2086.13 I // I _ / 1 I / I \ 0.57 AC I 0.68 AC 249.6 SF \ — — — (TYP.) I III' / 0.70 AC --29 - — i i i 1 I i (30301.3 SF I // � / / / / - 84.6 SF/ / / FFE: 2110 / \ STA 5+13 WATER LINE "B" 1 3 1 I II FFE: 2094 // 20 60 SF '/ \ FFE: 2104 I // I \\ \� PROPOSED 8" GATE VALVE i o h FFE:I 2099 ! I / ! /. 1 _ _ — \\ NO10 J J (WV #4) (TYP.) SANITARY SEWER MANHOLE I TOP EL: 2087.59' " 1 11 I I I 11 / //,� I 1 I I \ \ I / �' �/� J \ 1 • � �� P STA 12+12 WATER PROPOSED BLOWOFF LINE "B" VALVE (TYP.) � 0 > O U 12" PVC IN (SE) I.E.: 2079.34' 12" PVC OUT (NW) I.E.: 2079.16' �9I 11 II I 1 // /' /'',// / _ / ' / / 1 I I / / / /' / / WV 6 ( # ) Q O ti I �5+00 — f O I I _ / L I I 7+00 co PROPdSED STORMWATER PIPE (TYP.) \ +� ED Z � SEE STORM WATER AND I 1 \ 9+00� PROPOSED 20' WATER 1 GRADING PLAN) I � I f \ \F° o fi I I EASEMENT (TYP.) [­ I I I I I I - __ / NO. DATE BY REVISION DESCRIPTION O Q Z O WATER LINE B PROFILE Up U) U o Z SCALE: HORIZ. 1 "= 50'O "= Q 0 VERT. 1 5' O 2120 2120 > 0 O >- Z W PROPOSED GRADE (TYP.) PROPOSED 18" HDPE IPE; Q Q Z Z 0° > PROPOSED 2' MIN 18" VERTICAL = W 2115 w Q Q SDR -21 PVC WATER SEPARATION 2115 (� _ UJ >of LINE (TYP.); EQUIRED w Q = f 3 MIN COVER L a X. c� of REQUIRED cu Q 3 a0 ca o o ~ co 2110�000 > 2110 Lu m Z uj U x m +NNN r- 0 00 J Q> O D Lu� o p z m z v 0) IL CLCL H �� Z Q v) 0 z o c » '� W °° (Alcu a- a_ a_ ch JQZ Z> m 0 00 O O U O OU °r° d 2105 00 PROPOSED 18 HDPE > Q a Of � 2105 w J Zw PIPE; w _ MIN 18" VERTICAL W 3= a o w a w PROPOSED 8" DIP SEPARATION Q ^ o a 3 m i O N ~ a > WATER LINE (TYP.); REQUIRED 2100 3z 3' MIN COVER M o o 2 +W �p 2100 w oo 0 w Q REQUIRED p V))M< _ w w 0 a F -W OW 11> w �n a 0 Nd 7 L_ 0 ED - 2095 — 2095 LL �/ 1" W Z Q Q 2090*OEMmasomm 2090 J EXISTING GRADE (TYP.) � PROPOSED 8" DIP 2085 PROPOSED 8" DIP SEWER LINE; 2085 SEWER LINE; EXISTING CULVERT (TYP. MIN 18" VERTICAL MIN 18" VERTICAL -------._,SEPARATION SHEET SEPARATION—EQUIRED REQUIRED —1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 SEE DETAILS FOR TYPICAL PAVEMENT REPAIRED IN ACCORDANCE ►"�1 FINISHED GRADE PAVEMENT REPLACEMENT SECTIONS WITH NCDOT DETAIL 654.01 IPE PRODUCTS O TRACE -SAFE CONNECTOR #107 VAL X (H20) IN- N TH LOCATING CDP OR APPROVED E U AND MOUNTING H OUNT TO W PVC RISER WITH 304 S FORD STAINLESS STEEL CONCRETE" CLASS B CONCRETE THRUST*4t' TAPPING SLEEVE W BLOCK z UNDISTURBED EARTH ��/%\�/%\ -//��i /\ ��\\ - j/�\\j\\j�/ / ISHD GRADE GATE VALVE • I�I U ISHED GRADE IN UNPAVED �1 UNDI!3TURBED IN PA (SEE INSTALLATION DETAIL) BACKnLL SHALL BE COMPACTED ro THE REQUIREMENTS OF THE NOTES BELOW.CONTINUOUS TRACER WIREBACKFILL SHALL BE COMPACTED ABC AS\%\/r h� AS SPECIFIED BELOW - v ('ONTINUOUS TRACER WIRE - SPECIFIED UNDER NCDOT SECTION 1008./\/��\\/�\�j\//�\�j\\�\\� DUCTILE IRON AS SPECIFIED BELOW WATER LINE 12" CABC IT �^y NOTE. EXISTING MAIN DUCTILE IRONo v WATER LINE o rc 1/8" () 8" PVC, SDR 35 I z �w w 12" X 12" AND 16' X 16" TAPPING Zp DRILL HOLES IN PVC RISER AS (RISER) inv SLEEVES ARE NOT ALLOWED. PLAN .� io o REQ D. FOR WIRE PENETRATION GATE VALVE O Q+ HIGH DENSITY (SEE INSTALLATION DETAIL) PLASTIC VALVE CENTERING RING ll TRACE-SAFE®MAIN I� O TO LATERAL C, CONN - 19 00 24" MAXIMUMCONCRETE THRUST I••�•4 00 CONCRETE THRUST BLOCKTi N BLOCK C.) z TRENCH 12" MIN. +OUTSIDE DIAMETER OF PIPE- -�E® W z1 WIDTH 1 24" MAX. +OUTSIDE DIAMETER SOF PIPE TRACING w f T a I NOTES: z I TRENCH 12" MIN. + OUTSIDE DIAMETER OF PIPE_ - - - H� W � ~ WIDTH o 24" MAX. + OUTSIDE DIAMETER OF PIPE o oNOTESO �- + a D.I. CL. 350 WATER LINE o o 1. TRENCHES I7(CAVATED OUTSIDE EXISTING ROAD AND RAILWAY RIGHTS-OF-WAY SHALL BE BE BACKFILLED WITH COMMON BACKFILL MATERIAL CONSISTING OF EAPPROXIMATELY HORIZONTAL LAYERS. MATERIAL SHALL BE FREE OF ROOTS, STONES, AND DEBRIS. ALL MATERIAL SHALL HAVE AN IN-PLACE DENSITY OF AT XCAVATED MATERIALS EXCEPT HIGHLY ORGANIC SILTS AND CLAYS AND TAMPED THOROUGHLY. FILL SHALL BE DEPOSITED IN SUCCESSIVE, UNIFORM, 1. THIS TRENCH BACKFILL DETAIL APPLIES TO AREAS UNDER PAVEMENT AND AREAS WHERE THE TRENCH IS WITHIN FIVE (5) FEET OF MAIN o o W Q LEAST 85% OF MAXIMUM DRY DENSITY (STANDARD PROCTOR) OR AS APPROVED BY THE ENGINEER. COMMON BACKFILL SHALL NOT CONTAIN STONE THE EDGE OF PAVEMENT. ISI BLOCKS, BROKEN CONCRETE, MASONRY RUBBLE, OR OTHER SIMILAR MATERIALS. IT SHALL HAVE PHYSICAL PROPERTIES SUCH THAT IT CAN BE READILY 2. COMPACTION OF THE BACKFILL SHALL BE ACHIEVED THROUGH THE USE OF AN APPROVED VIBRATORY PLATE TAMPER OR ROLLER. XISTING MAIN SPREAD AND COMPACTED DURING FILLING. SNOW, ICE, AND FROZEN SOIL WILL NOT BE PERMITTED. RESTRAINED DIMJ OR FORD STAINLESS STEEL w W WHERE EXCAVATED MATERIAL, AFTER REMOVAL OF ROCKS, STUMPS, PLANT MATERIAL, AND OTHER EXTRANEOUS MATERIAL AND PROPER DEWATERING, DRYING, 3. COMPACTION TESTING OF THE BACKFILL SHALL BE PROVIDED, DIRECTED AND COORDINATED BY THE OWNER. INTERVALS OF TESTING YDRANT "TEE" TAPPING SLEEVE W SHALL BE AT THE TOTAL DISCRETION OF THE OWNER AND MAY BE CHANGED AT ANY TIME. PROTECTION, AND STORAGE OF THE EXCAVATION BY THE CONTRACTOR, CANNOT BE PREPARED TO MEET THE REQUIREMENTS FOR COMMON BACKFILL, DUE �+ TO THE NATURE OF THE MATERIAL (E.G., EXCESSIVE ROCK, MUCK, ORGANICS, CLAY, SILT, OR OTHER MATERIAL), AND AS DETERMINED BY THE ENGINEER, IF A TEST DOES NOT PASS, THE CONTRACTOR SHALL REMOVE THE DEFECTIVE BACKFILL, REDO THE WORK AND THE AREA WILL BE APPROVED RESTRAINT DEVICE ELEVATION I� THE UNACCEPTABLE EXCAVATION SHALL BE REMOVED FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR AND REPLACED BY IMPORTED BACKFILL RETESTED. THE CONTRACTOR SHALL BE AWARE OF THE LEVEL OF COMPACTION REQUIRED. NOTES: MEGALUG OR EQUAL onQ MEETING THE REQUIREMENTS OF STRUCTURAL BACKFILL. IMPORTED STRUCTURAL BACKFILL SHALL BE FREE OF ORGANICS, ROOTS OR OTHER DELETERIOUS MATERIALS AND SHALL NOT CONTAIN MORE THAN FIVE PERCENT (BY WEIGHT) ORGANIC MATERIAL, HAVE A PLASTICITY INDEX (PI) GREATER THAN 25, OR IF THE WORK IS SUSPECT TO BE DEFECTIVE BY THE OWNER, THE WORK SHALL BE RETESTED. 1. TOP OF COVER SHALL BE STAMPED "WATER" HAVE A MAXIMUM DRY DENSITY LESS THAN 90 POUNDS PER CUBIC FOOT. IMPORTED STRUCTURAL FILL SHOULD CONSIST OF MATERIAL CLASSIFIED AS ML, O CL, SC, OR SM, OR BETTER PER ASTM D-2487 AND BE CAPABLE OF BEING COMPACTED TO 85% STANDARD PROCTOR. THE WATER CONTENT OF THE BACKFILL MATERIAL SHALL ALSO BE TESTED AND RECORDED FOR EACH TEST COMPLETED. THE 2. VALVE PAD REQUIREMENTS SHALL NOT BE APPLICABLE FOR PAVED SURFACES. a/ CONTRACTOR WILL BE ALLOWED TO ADD WATER TO THE BACKFILL MATERIAL IN ORDER TO OBTAIN THE OPTIMUM WATER CONTENT. NOTE: 2. THE WATER LINE SHALL HAVE A MINIMUM OF 3' OF COVER AT FINISHED GRADE. HOWEVER, THE CONTRACTOR WILL NOT BE ALLOWED TO UTILIZE THE ADDITION OF WATER AS A MEANS OF COMPACTION. 3. PAVEMENT REPAIR SHALL MATCH EXISTING ROAD PAVING SECTION. SEE NCDOT FURTHERMORE, SHOULD THE BACKFILL MATERIAL BE FOUND TO HAVE WATER CONTENT RATIOS WHICH IN THE OPINION OF THE ASPHALT REPAIR DETAIL # 654.01. 12" X 12" AND 16' X 16" TAPPING SLEEVES ARE NOT ALLOWED. TABLE A-1 Trl v� TRACER WIRE WILL BE A 19 GAUGE, TIN COATED, COPPER CONDUCTOR WITH POLYETHYLENE INSULATION. CORE MATERIAL COMPRISED OF HIGH -TENACITY, ENGINEER OR THE OWNER PREVENTS THE APPROPRIATE COMPACTION OF THE TRENCH, THE CONTRACTOR SHALL REMOVE ALL F�••I v� WOVEN POLYESTER WITH WATER BLOCKING YARNS ENCAPSULATED IN 30 MIL. BLUE HDPE JACKET PROVIDING CORROSION RESISTANCE, FLEXIBILITY, IMPACT DEFECTIVE MATERIAL AND UNDERTAKE THE NECESSARY CORRECTIVE WORK. 4. WHEN OPERATING NUT DEPTH EXCEEDS 3'-0" BELOW FINISHED GRADE, PROVIDE EXTENSION STEM WITH TBD STRENGTH AND 1800 LBS. TENSILE STRENGTH. TRACER WIRE WILL NOT CONDUCT AN ELECTRICAL CURRENT WHEN STRUCK BY LIGHTNING AND IS DESIGNED STANDARD 2" SQUARE OPERATING NUT. TOP OF NUT SHALL BE WITHIN 5" TO 9" OF FINISHED GRADE. FOR DIRECT BURY AND DIRECTIONAL BORING APPLICATIONS. WHEN SPLICES AND LATERAL CONNECTIONS ARE MADE, ONLY GEL FILLED CONNECTORS 4. THE WATER LINE SHALL HAVE A MINIMUM OF 3' OF COVER AT FINISHED GRADE. DESIGNED FOR WIRE WITH WOVEN POLYESTER FIBER CORE ARE TO BE USED. TRACER WIRE AND CONNECTORS SHALL BE TRACE -SAFE® WATER BLOCKING 5. TRACER WIRE WILL BE A 19 GAUGE, TIN COATED, COPPER CONDUCTOR WITH POLYETHYLENE INSULATION. NOTE;_ TRACER WIRE AND RELATED CONNECTORS, MANUFACTURED BY NEPTCO, INC., OR EQUIVALENT APPROVED BY ENGINEER, AND PRODUCED IN THE UNITED 5. TRACER WIRE WILL BE A 19 GAUGE, TIN COATED, COPPER CONDUCTOR WITH POLYETHYLENE INSULATION. CORE MATERIAL COMPRISED CORE MATERIAL COMPRISED OF HIGH -TENACITY, WOVEN POLYESTER WITH WATER BLOCKING YARNS STATES OF AMERICA. OF HIGH -TENACITY, WOVEN POLYESTER WITH WATER BLOCKING YARNS ENCAPSULATED IN 30 MIL. BLUE HDPE JACKET PROVIDING ENCAPSULATED IN 30 MIL. BLUE HDPE JACKET PROVIDING CORROSION RESISTANCE, FLEXIBILITY, IMPACT 1. CONCRETE SHALL BE 3000 PSI. CORROSION RESISTANCE, FLEXIBILITY, IMPACT STRENGTH AND 1800 LBS. TENSILE STRENGTH. TRACER WIRE WILL NOT CONDUCT AN STRENGTH AND 1800 LBS. TENSILE STRENGTH. TRACER WIRE WILL NOT CONDUCT AN ELECTRICAL TRACER WIRE SHALL BE EXTENDED ALONG ALL WATER LINES, FITTINGS, VALVES, SERVICES, AND HYDRANTS. LOCATING CLIPS SHALL BE PROVIDED AT ALL ELECTRICAL CURRENT WHEN STRUCK BY LIGHTNING AND IS DESIGNED FOR DIRECT BURY AND DIRECTIONAL BORING APPUCATIONS. CURRENT WHEN STRUCK BY LIGHTNING AND IS DESIGNED FOR DIRECT BURY AND DIRECTIONAL BORING 2. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF `} VALVES, HYDRANT VALVES AND METER BOXES. THE CONTRACTOR SHALL DUCT TAPE TRACER WIRE ON CROWN OF WATER LINE EVERY FIVE FEET. WHEN SPLICES AND LATERAL CONNECTIONS ARE MADE, ONLY GEL FILLED CONNECTORS DESIGNED FOR WIRE WITH WOVEN POLYESTER APPLICATIONS. WHEN SPLICES AND LATERAL CONNECTIONS ARE MADE, ONLY GEL FILLED CONNECTORS MECHANICAL JOINT FITTINGS BY THE INSTALLATON OF � / FIBER CORE ARE TO BE USED. TRACER WIRE AND CONNECTORS SHALL BE TRACE -SAFE& WATER BLOCKING TRACER WIRE AND DESIGNED FOR WIRE WITH WOVEN POLYESTER FIBER CORE ARE TO BE USED. TRACER WIRE AND POLYETHYLENE FILM PLACED BETWEEN THE FITTINGS AND RELATED CONNECTORS, MANUFACTURED BY NEPTCO, INC., OR EQUIVALENT APPROVED BY ENGINEER, AND PRODUCED IN THE UNITED CONNECTORS SHALL BE TRACE -SAFE® WATER BLOCKING TRACER WIRE AND RELATED CONNECTORS, POURED CONCRETE. ui J STATES OF AMERICA. MANUFACTURED BY NEPTCO, INC., OR APPROVED EQUIVALENT, AND PRODUCED IN THE UNITED STATES OF O AMERICA. 3. SEE TABLE A-1 FOR AREA OF CONCRETE REQUIRED FOR MAIN TRACER WIRE SHALL V EXTENDED ALONG ALL WATER DIVES, ORES. T, VALVES, SERVICES, AND HYDRANTS. LOCATING CLIPS SHALL SIZED 6 -INCH THROUGH 16 -INCH. BE PROVIDED AT ALL VALVES, HYDRANT VALVES AND METER BOXES. THE CONTRACTOR SHALL DUCT TAPE TRACER WIRE ON CROWN OF WATER LINE EVERY FIVE FEET. U— W O DATE: 01/12/2019 WD DWG. NO. 2 DATE: 01/12/2019 WD DWG. NO. 3 DATE: 01/12/2019 WD DWG. NO. 5 DATE: 01/12/2019 WD DWG. NO. 6 ,NDERs ,14DERs ENDERS �NDERs SCALE: NOT 10 SCALE WATER TRENCH CONSTRUCTION o uti Ste` NOT 10 SCALE WATER TRENCH CONSTRUC-PION o °tip SCALE' NOT TO SCALE o Dti� SCALE: NOT TO SCALE STANDARD TAPPING SLEEVE o Dti� City of Hendersonville Engineering Department F ' Cit of Hendersonville Engineering Department �City of Hendersonville Engineering Department Cit of Hendersonville Engineering Department qt.VALVE INSTALLATION DETAIL ry .. t.. 305 Williams Street ( m OUTSIDE PAVEMENT u - m 305 Williams Street UNDER PAVEMENT u `�'• 305 Williams Street V ---,• m 305 Williams Street AND VALVE ASSEMBLY u m Hendersonville, 28792 Hendersonville, NC 28792 Hendersonville, NC 28792 Hendersonville, NC 28792 � , 1(828) 697-3000 (office) �� 1(828) 697-3000 (office) �y � (828) 697-3000 (office) �� 2 (828) 697-3000 (office) www.citvofhendersonville.org 1847 www.citvofhendersonville.org 1847 www.ciNrn ofhendersonville.o1847 www.citvofhendersonville.org 1847 Z J1LLE . 1 BALL VALVE OO � C' � t� '1'O (COMPRESSIO S � Q Q' Q' METAL METER BOX, •T 2' OFF R/W OR EALLI SEMENT II r, __________ MUST NOT BE LOCATED IN DITCH i r A OND WDER PLATED W Z d OR ON SLOPE Z •i "xY TEE 1" COPPER MALExF (OPEN BOTTOM) > O S ••• y 2 y OR LOK-PAK O PD 2 "TEE OA117� METER(MALExF METER BOX AND UD A.L.117 r ID IS NO = g HOLE IN TOP. w W I`I2" PEX 2" PEX a OR > Z o FINISHED IJ J o `II Q QCUT VALVE W/ BOX A / CUSTOMER CUU T J T O W Q , $ J BOX 154" SPOOL PIECE THREADED) ALL VALVE y 7 (n Qzw ACTUAL METER L^ z w S ( j \\\\\\\\\\ W 0 > 0 0 BY I OHALL 2 PI W o S BALL VALVE ( W M v Z � THREAD ' BLE SERVICE PIPE \\ � JTiREADEDxSL G p CROSS—LINKED PO L \/\/\/\// l�\�\��\�\\�j \ Z J Lu CNH TO 2" METER STONE UNDER LL O IN 2" METE PLAN ( f) Q z NOT TO SCALE O 1000—NL AIR RELEASE V n/ 000—NL (SEE WATER DETAIL D 0LLJ Q _j CORPORAT n BLAIR 313 DOUBLE BALEO O SERVICE SAD 4 STAINLESS 2 SERVICELLI STEEL BALE, NUTS AN S �/ CROSS—UNKED POLY PIPE 0 C `) Q U) > INGED V ��� ///'''��� U Q F,,/ J Z IR 313 DOUBLE BALE Vw/\ 7 PADLOCK READER -LID Q SERVICE SAD 4 STAINLESS � UD RECESS .EEL BALE, NUTS AND C/) j ELEVATION VIEW N 0 Q 0 QQXX,,SEE VALVE O 06 ' v � �� � INSTALLATON� J NOTES,' O c 1. THE CITY OF HENDERSONVILLE SHALL INSTALL WATER METERS 1. PIPE SIZE OFOTFITTINGS SIZE HE PROPOSED NR SHALL MATCH THE VALVE E AS SERVICE TAPS ARE APPLIED FOR. �> �\\ \ \\��\\ \\� \\�\\��\moi I I I TO BE INSTALLED. 0 y 2 CEXTEND O PER CONDUCTOOR WITH POLYETHRE FROM MAIN YLENE INSULATION. CORE MATERIAL COMPRISEDTER BOX. WIRE NOT SHOWN FOR OFF HIGHITY. TRACER -TENACITY, WOVEN POLYESTER WITH WATER > d W IRE WILL BE A 19 GAUGE, TIN COATED, O \ / \\/ / \\ /\j\\\. /r 2. LOCATION TO BE THE SAME AS METER BOX C-i,� o BLOCKING YARNS ENCAPSULATED IN 30 MIL. BLUE HDPE JACKET; PROVIDING CORROSION RESISTANCE, FLEXIBILITY, IMPACT STRENGTH o �\ / \\�\� \\!\ % \` DETAILS. N c DESIGNEDND OFORD ECTLE STRENGTH. BURY AND DIRECTIONACER L11RE WILL NOT BORING APPLICATIONS. WHEN SPLICES ANDAN ELECTRICAL RRENT WHEN LATERAL CONNECTIONUCK SYARE MADE, ONLY IS c d N H=- 3. 3. TRACER WIRE NOT SHOWN FOR CLARITY. eu U 0 GEL FILLED CONNECTORS DESIGNED FOR WIRE WITH WOVEN POLYESTER FIBER CORE ARE TO BE USED. TRACER WIRE SHALL BE b U o c = Lu I TRACER WIRE SHALL BE CONNECTED TO c Z o TERMINATED IN METER BOX AT MOUNTED TRACE -SAFE® LOCATING CLIP, MOUNTED A MAXIMUM OF 3" FROM TOP OF BOX WITH 304 SS Z p W WATER MAIN TRACER USING CONNECTORS c E Qi c BOLT. TRACER WIRE AND CONNECTORS SHALL BE TRACE -SAFE® WATER BLOCKING TRACER WIRE AND RELATED CONNECTORS, c E m C) APPROVED BY THE MANUFACTURERS. W m = co iMANUFACTURED BY NEPTCO, INC., OR EQUIVALENT APPROVED BY ENGINEER, AND PRODUCED IN THE UNITED STATES OF AMERICA. m m � m y m = 000, L n c (SEE VALVE BOX INSTALLATION) r rn 2" HARD TEMPERED, STRAIGHT TYPE "K" O c LO m c O c � 0 2_ COPPER OR BRASS 4. ACTUAL LOCATION OF AIR RELEASE VALVE o 0 aO po o o m ao SHALL BE COORDINATED WITH THE CITY AND NQ ro v a N p y M m v 2" PEX 2" PEX L PROPERTY OWNER. \ F _ N F _ ~ rJ U 15 SPOOL PIECE 06 W m > > ACTUAL METER Z W W W 6 - HED STONE 0 BE INSTALL , , W UNDER M — BY COH) Q z LY] z Q � ELEVATION m o z w LD LD Z o NOT TO SCALE Q Q W Q W 0 J 00 Cn 0) DATE: 01/12/2019 WD DWG. NO. 10 rDE RS 2 E1 A o �• NOT TO �� 2" METER BOX City ofHenderso WillEnsStrengDepartment AND INSTALLATION u �,•tI� m 305 Williams Street Co / / �+ 0 Il Hendersonville, NC 28792 (828) 697-3000 (office) 01 c f 7 www.cityofhendersonville.org 1847 m Q 4/30/201911:13:46 AM, mpomraning I' I (///^/ U EZ W v / J rn 0 Q Iv m W J W Y a LuQ 0 0 U 0 U) M C G o 0 Co 00 SHEET _o Do=508J NO. I DATE I BY I REVISION DESCRIPTION FIRE HYDRANT STORZ NOZZLE 0 �O iv 24" X 24" X 6" O O CLASS B CONCRETE PAD Of w A C.Y. OF #57 WASHED STONE (TYP)!�, z \% RESTRAINED JOINT i•1 AWWA C153 I OFFSET CONNECTOR PIPE bow M J 6"X6" 6"X12" 6"X24" A 16" 1 30" 41- B 6" 1 12" 24" SIZE 6" DIA. X OFFSET RESTRAINED JOINT— RESTRAINED JOINT SPLIT GLAND PRESSURE CLASS 350 DI PIPE "WATER" INTO TOP X 24" X 6" ;S B CONCRETE PAD r—FINISHED GRADE VALVE ILLATION DETAIL STRAINED JOINT I Q � Q U) LU z Of LL Q 0 J LJJ r) \—AWWA C153 DI OFFSET CONNECTOR PIPE O.D. OF 6" AWWA C153 RESTRAINED JOINT M DI PIPE=6.90" M.J. CONNECTION WITH IRON RESTRAINED JOINT RETAINING GLAND M.J. RESTRAINT E A (SEE RESTRAINT DETAIL) r co TOTAL LENGTH OF OS PIPE p N o m w a a >O c cc) .2 _ N > NOTES: (.) 0 C. 1. SEE FIRE HYDRANT STANDARD INSTALLATION M. Z N DETAIL FOR ADDITIONAL REQUIREMENTS. cE d o W M=M c 2. ALL VALVES AND HYDRANTS SHALL HAVE M.J. O > N 0 w CONNECTIONS WITH IRON RETAINING GLAND M.J. c RESTRAINT. p Q N a a N 'D 3. FIRE HYDRANT OFFSET CONNECTOR SHALL BE N r ac) 3 PLACED AS APPROVED BY THE ENGINEER. _ 4. OFFSET CONNECTOR SHALL NOT BE BACK o FILLED UNTIL INSPECTED AND APPROVED BY ENGINEER. F< CJ G USE 4" X 16" X 8" SOLID CONCRETE BLOCKS UNDER BEND ON #57 WASHED STONE BASE LAYER (6" MIN) NOTES: 1. FIRE HYDRANTS SHALL BE RATED TO A MINIMUM 250 PSI WORKING PRESSURE IN ACCORDACE WITH AWWA C-502 UNLESS SPECIFIED AS 350 PSI BY THE CITY. HYDRANTS SHALL HAVE A 51f–INCH BARREL AND STORZ CONNECTION. 2. ALL VALVES AND HYDRANTS SHALL HAVE M. J. CONNECTIONS WITH IRON RETAINING GLAND M.J. RESTRAINT. 3. FIRE HYDRANT SHALL BE FACTORY PAINTED YELLOW, WITH FIELD PAINTED TOUCH–UP, BEFORE PROJECT IS ACCEPTED. 4. HYDRANT VALVE SHALL BE PLACED AS CLOSE AS POSSIBLE TO THE MAIN, BUT DO NOT PLACE VALVE IN PROPOSED OR EXISTING CURB AND GUTTER. IF THE STREET IS SOIL AND NO PAVING IS TO BE DONE AT THIS TIME, THE LOCATION OF THE VALVE IS TO BE DETERMINED BY THE ENGINEER. 5. FIRE HYDRANTS SHALL BE PLACED AS DIRECTED BY THE ENGINEER. 6. HYDRANT BRANCH SHALL NOT BE BACK FILLED UNTIL INSPECTED AND APPROVED BY THE ENGINEER. 7. GATE VALVE AND BOX SHALL BE IN ACCORDANCE WITH STANDARD DETAIL. 8. HYDRANT EXTENSIONS AND/OR OFFSETS SHALL BE APPROVED BY THE ENGINEER. 9. FIRE HYDRANTS WHICH HAVE BEEN INSTALLED MUST BE TAGGED "OUT OF SERVICE" AND BAGGED, UTILIZING A RED CANVAS BAG WITH WHITE LETTERING, UNTIL SUCH TIME AS THE WATER MAIN TO WHICH CONNECTED IS DISINFECTED AND CONNECTED TO THE ACTIVE WATER SYSTEM. DATE: 04/24/2019 WD DWG. NO. 12 SCALE: NOT M SCALE City of Hendersonville Engineering Department 305 Williams Street Hendersonville, NC 28792 (828) 697-3000 (office) www.cityofhendersonville.org FIRE HYDRANT STANDARD INSTALLATION DETAIL JOINT RESTRAINT (SEE RESTRAINT DETAIL) 06 SECTION "B -B" FRONT VIEW SECTION "A -A" IRON RETAINING GLAND M.J. RESTRAINT NOMINAL PIPE SIZE I- 2' MIN. BOLTS QUANTITY RATING 6" FIRE HYDRANT 6 350 8" 4 6 5-1/4" STORZ NOZZLE WORD "WATER" 8 8 350 55' CAST INTO TOP 8" 72' 40' 17' 8' 8"X6" 30' 12" 102' 57' 24' 1 12' 12"X8" 54' 00 24" X 24" X 6" B CONCRETE PAD 24" X 24" X 6" z CLASS B CONCRETE PAD O O ;0 0 O N [CLASS FINISHED GRADE I—� N zC/) N U) LLI U)Q z Ov �O OLr U(j) O U (�l FSI 00 N INSTALLATION DETAIL z U OQ � z RESTRAINED HYDRANT TEE 006 \//\\ \/ �O� DETAIL) �_ �z QQ w o rSEERESTRAINT =w Ys C.Y. OF N57 WASHED STONE . . \�i, w x W¢ USE 4" X 16" X 8" SOLID CONCRETE BLOCKS UNDER BEND ON #57 WASHED STONE BASE LAYER (6" MIN) NOTES: 1. FIRE HYDRANTS SHALL BE RATED TO A MINIMUM 250 PSI WORKING PRESSURE IN ACCORDACE WITH AWWA C-502 UNLESS SPECIFIED AS 350 PSI BY THE CITY. HYDRANTS SHALL HAVE A 51f–INCH BARREL AND STORZ CONNECTION. 2. ALL VALVES AND HYDRANTS SHALL HAVE M. J. CONNECTIONS WITH IRON RETAINING GLAND M.J. RESTRAINT. 3. FIRE HYDRANT SHALL BE FACTORY PAINTED YELLOW, WITH FIELD PAINTED TOUCH–UP, BEFORE PROJECT IS ACCEPTED. 4. HYDRANT VALVE SHALL BE PLACED AS CLOSE AS POSSIBLE TO THE MAIN, BUT DO NOT PLACE VALVE IN PROPOSED OR EXISTING CURB AND GUTTER. IF THE STREET IS SOIL AND NO PAVING IS TO BE DONE AT THIS TIME, THE LOCATION OF THE VALVE IS TO BE DETERMINED BY THE ENGINEER. 5. FIRE HYDRANTS SHALL BE PLACED AS DIRECTED BY THE ENGINEER. 6. HYDRANT BRANCH SHALL NOT BE BACK FILLED UNTIL INSPECTED AND APPROVED BY THE ENGINEER. 7. GATE VALVE AND BOX SHALL BE IN ACCORDANCE WITH STANDARD DETAIL. 8. HYDRANT EXTENSIONS AND/OR OFFSETS SHALL BE APPROVED BY THE ENGINEER. 9. FIRE HYDRANTS WHICH HAVE BEEN INSTALLED MUST BE TAGGED "OUT OF SERVICE" AND BAGGED, UTILIZING A RED CANVAS BAG WITH WHITE LETTERING, UNTIL SUCH TIME AS THE WATER MAIN TO WHICH CONNECTED IS DISINFECTED AND CONNECTED TO THE ACTIVE WATER SYSTEM. DATE: 04/24/2019 WD DWG. NO. 12 SCALE: NOT M SCALE City of Hendersonville Engineering Department 305 Williams Street Hendersonville, NC 28792 (828) 697-3000 (office) www.cityofhendersonville.org FIRE HYDRANT STANDARD INSTALLATION DETAIL JOINT RESTRAINT (SEE RESTRAINT DETAIL) 06 SECTION "B -B" FRONT VIEW SECTION "A -A" IRON RETAINING GLAND M.J. RESTRAINT NOMINAL PIPE SIZE WEDGES QUANTITY BOLTS QUANTITY RATING 6" 3 6 350 8" 4 6 350 12" 8 8 350 8" SIZE SHOWN 6" & 12" SIMILAR IRON RETAINING GLAND M.J. RESTRAINT 10 BE � .:EnG SEE cAW'T RESTPH EO SEE e DATE: 01/12/2019 WD DWG. NO. 4-1 SCALE: NOT M SCALE City of Hendersonville Engineering Department 305 Williams Street Hendersonville, NC 28792 (828) 697-3000 (office) www.citvofhendersonville.ora DUCTILE IRON PIPE RESTRAINT DETAIL SHEET IOF2 RESTRAINED JOINT DETAIL FOR TYPICAL TEE INTERSECTION 4 WAY INTERSECTION SIMILARLY RESTRAINED NOTES: 1. THRUST RESTRAINT SHALL BE INSTALLED ON DUCTILE IRON WATER DISTRIBUTION UNES 6" THRU 12" DIAMETER IN THE MANNER SHOWN. 2. IRON RETAINING GLAND M.J. RESTRAINT OR OTHER FORMS OF IRON RESTRAINT SHALL NOT BE USED ON PVC PIPE. 3. PIPE GREATER THAN 12 INCH DIAMETER SHALL REQUIRE RESTRAINED JOINT PIPE FOR THE PROPER LENGTH. 4. COMPACT FITTINGS ARE ACCEPTABLE FOR USE WITH IRON RETAINING GLAND M.J. RESTRAINT AND OTHER FORMS OF DI RESTRAINT. DATE: 01/12/2019 WD DWG. NO. 4-2 SCALE: NOT TO SCALE City of Hendersonville Engineering Department 305 Williams Street Hendersonville, NC 28792 (828) 697-3000 (office) www.citvofhendersonville.om 5. THE MINIMUM LENGTH OF RESTRAINT INDICATED SHALL REQUIRE ALL JOINTS WITHIN THE LR DISTANCE TO BE RESTRAINED. 6. RESTRAINT SYSTEM SHALL BE INSPECTED AND APPROVED PRIOR TO BACKFILLING. 7. RESTRAINT SYSTEMS MAY VARY BASED UPON THE ENGINEERS' DESIGN AS SHOWN ON THE PLAN AND PROFILE SHEETS. 8. GRIPPER RING AND FIELD LOK GASKETS ARE AN ACCEPTABLE METHOD OF RESTRAINT ON DUCTILE IRON PIPE ONLY. 9. TRACER WIRE NOT SHOWN FOR CLARITY. WIRE SHALL BE INSTALLED PER OTHER DETAILS. 10. M.J. SHALL BE PRODUCED IN USA. DUCTILE IRON PIPE RESTRAINT DETAIL SHEET 2 OF 2 REVISION DESCRIPTION LR (MIN. LENGTH OF RESTRAINT EACH DIRECTION OF THRUST IN LINEAR FEET) Based on 200 psig pressure, Safety Factor of 2.0:1, BARE DI PIPE AND ML Soil, 3.5' cover O z Chart does not apply to pipes wrapped in polyethylene wrap PIPE VALVES 90' 45' ELBOW 22-1/2' SIZE DEAD ENDS ELBOWS & CROSSES ELBOWS REDUCER W TEES 6" 55' 31' 13' 7' 8"X2" 67' 8" 72' 40' 17' 8' 8"X6" 30' 12" 102' 57' 24' 1 12' 12"X8" 54' 10 BE � .:EnG SEE cAW'T RESTPH EO SEE e DATE: 01/12/2019 WD DWG. NO. 4-1 SCALE: NOT M SCALE City of Hendersonville Engineering Department 305 Williams Street Hendersonville, NC 28792 (828) 697-3000 (office) www.citvofhendersonville.ora DUCTILE IRON PIPE RESTRAINT DETAIL SHEET IOF2 RESTRAINED JOINT DETAIL FOR TYPICAL TEE INTERSECTION 4 WAY INTERSECTION SIMILARLY RESTRAINED NOTES: 1. THRUST RESTRAINT SHALL BE INSTALLED ON DUCTILE IRON WATER DISTRIBUTION UNES 6" THRU 12" DIAMETER IN THE MANNER SHOWN. 2. IRON RETAINING GLAND M.J. RESTRAINT OR OTHER FORMS OF IRON RESTRAINT SHALL NOT BE USED ON PVC PIPE. 3. PIPE GREATER THAN 12 INCH DIAMETER SHALL REQUIRE RESTRAINED JOINT PIPE FOR THE PROPER LENGTH. 4. COMPACT FITTINGS ARE ACCEPTABLE FOR USE WITH IRON RETAINING GLAND M.J. RESTRAINT AND OTHER FORMS OF DI RESTRAINT. DATE: 01/12/2019 WD DWG. NO. 4-2 SCALE: NOT TO SCALE City of Hendersonville Engineering Department 305 Williams Street Hendersonville, NC 28792 (828) 697-3000 (office) www.citvofhendersonville.om 5. THE MINIMUM LENGTH OF RESTRAINT INDICATED SHALL REQUIRE ALL JOINTS WITHIN THE LR DISTANCE TO BE RESTRAINED. 6. RESTRAINT SYSTEM SHALL BE INSPECTED AND APPROVED PRIOR TO BACKFILLING. 7. RESTRAINT SYSTEMS MAY VARY BASED UPON THE ENGINEERS' DESIGN AS SHOWN ON THE PLAN AND PROFILE SHEETS. 8. GRIPPER RING AND FIELD LOK GASKETS ARE AN ACCEPTABLE METHOD OF RESTRAINT ON DUCTILE IRON PIPE ONLY. 9. TRACER WIRE NOT SHOWN FOR CLARITY. WIRE SHALL BE INSTALLED PER OTHER DETAILS. 10. M.J. SHALL BE PRODUCED IN USA. DUCTILE IRON PIPE RESTRAINT DETAIL SHEET 2 OF 2 REVISION DESCRIPTION 3: � W J O z UL) 0 OJ J W � C � � z >O W 00 TT 1�1 w w � uu O N I—� N zC/) N U) LLI U)Q z Ov �O OLr U(j) O U (�l FSI 00 N z U OQ � z V1 006 �O� �_ �z QQ w o =w w x W¢ C/] W� M oN 2 < L � W Q MZC^) w WW w U C p Z uj W M U p N Z 2 I 0 Fz Q (0 Z o e V Q O w 06 J N °r° dT O Wkn kn 3: � W J O z w 0 OJ SHEET C-509 U Q z z J OJ J C >O U 00 (D= O zC/) U) LLI U)Q z Ov �O U(j) O U z OQ O 006 �O� �z QQ w o =w w C/) _ M oN 2 < L � 0 06LU Q MZC^) w WW w U C p Z uj W M U p N Z 2 I 0 Fz Q (0 Z o e m Q � W Q W O w 06 J N °r° dT SHEET C-509 �w°� 0 U U 45' R /W w w 4' ® 4% 4' ® 4% �--, 13.5' 16' 29; MIN. SLOPE 2" S9.5C r 2% 2%-� O � J �••, 31 �.1 � vNj ISI N PROPOSED ELECTRICAL SERVICE TO BE PROVIDED BY DUKE ENERGY i.//../i /i /i\//\ N 7 6 8" ABC � x pia COMPACTED SUBGRADE PROPOSED 8" WATER LINE a • U PROPOSED 8" SEWER LINE Z PROPOSED STORMWATER PIPE a ST TYPICAL PRIVATE ROAD �W 8 CROSS-SECTION w NOT TO SCALE w44 W I --I rn \.J Q O W w� 30' R/W 2' 0 4% 2' ® 4% 0 � 13.5' 12' 29; MIN. SLOPE � 2% 2%- Al o a a ° u: ° T /lf\\/\/\/\/\/\/\//\//\//\//\//\//\//\� 8" CONCRETE PAD 7 J Z PROPOSED WATER LINE (1 MIN. COMPACTED ABC — J O (100% STANDARD) �O >O U ST TYPICAL SHARED DRIVEWAY 00 8 CROSS-SECTION m NOT TO SCALE V) Q I� (D= O Z U) >- U) U) Q Z Ov � �p O U(/) U C) Z OQ p 006 U) �p w QZ o z U)w 0) �Q �o CD N} Q w w ao z °° w w 0 IY 0Y 0 z m zF-: Q z L1J CD 0 LD U) z o 00 H (n D (n z J O p Q w Q w 0 00 3 0 D 0 0 0 li /1 Z) O Lu /) Z J Q w� U U) 2 SHEET C=511 NO. DATE BY REVISION DESCRIPTION