Loading...
HomeMy WebLinkAbout20190875 Ver 1_Sewer Set_20190628HAYWOOD CROSSING SUBDIVISION SEWER PLAN SPANO & ASSOCIATES HENDERSON OWNER/DEVELOPER CONTACT: NAME: MR. RALPH SPANO COMPANY: SPANO & ASSOCIATES HAYWOOD, LLC ADDRESS: 1540 INTERNATIONAL PKWY #200, LAKE MARY, FL 32746 PHONE: 407-574-4060 EMAIL: SPAN01688@GMAIL.COM ENGINEER/EROSION CONTROL CONTACT: NAME: SCOTT BURWELL, P.E. COMPANY: MCGILL ASSOCIATES, P.A. ADDRESS: 55 BROAD STREET, ASHEVILLE, NC 28801 PHONE: 828-252-0575 EMAIL: SCOTT.BURWELL@MCGILLASSOCIATES.COM Know what's below. Call before you dig. N.C. One -Call Center Dial 811 or 1-800-632-4949 McGill 0- A S S O C I A T E S ENGINEERING -PLANNING -FINANCE 55 BROAD STREET ASHEVILLE, NC 28801 PH. (828) 252-0575 FIRM LICENSE # C-0459 COUNTY, N PROJECT SITE SYA HAYWOOD RD HAYWOOD KNOLLS DRIVE t�z FOR REVIEW ONLY JUNE 2019 HAYWOOD, NORTH CAROLINA SCHEDULE OF DRAWINGS G-001 ..... COVER SHEET G-002 ..... GENERAL NOTES AND LEGEND G-004 ..... UTILITY NOTES CD -101 ..... EXISTING CONDITIONS C-101 ..... MASTER PLAN C-506 ..... MISCELLANEOUS DETAILS C-507 ..... MISCELLANEOUS DETAILS -1 02 . . . . INITIAL EROSION CONTROL PLAN C-511..... MISCELLANEOUS DETAILS 10 FINAL EROSION CONTROL PLAN NOT INCLUDED WITH THIS SUBMITTAL C-106 ..... SEWER PLAN C-107 ..... PLAN PROFILE - SEWER LINE A & B C-108..... PLAN PROFILE - SEWER LINE B C-109..... PLAN PROFILE - SEWER LINE C NOT INCLUDED WITH - . . . . THIS SUBMITTAL GENERAL CONSTRUCTION NOTES 1. UNLESS OTHERWISE STATED, ALL FILL AREAS SHALL BE CONSTRUCTED IN LAYERS OF 8" MAXIMUM THICKNESS, WITH WATER ADDED OR SOIL CONDITIONED TO THE OPTIMUM MOISTURE CONTENT AS DETERMINED BY THE ENGINEER AND COMPACTED WITH A SHEEP'S FOOT ROLLER TO A COMPACTION EQUAL TO OR GREATER THAN 95% (100% IN THE TOP 2' OF THE SUB GRADE BELOW ROADWAYS AND PARKING LOTS) OF THE DENSITY OBTAINED BY COMPACTING A SAMPLE OF THE MATERIAL IN ACCORDANCE WITH THE STANDARD PROCTOR METHOD OF MOISTURE -DENSITY RELATIONSHIP TEST, ASTM D698 OR AASHTO-99 UNLESS SPECIFIED IN OTHER SPECIFICATIONS. 2. ENTIRE AREA TO BE GRADED SHALL BE CLEARED AND GRUBBED. NO FILL SHALL BE PLACED ON ANY AREA NOT CLEARED AND GRUBBED. 3. ALL SOIL EROSION CONTROL MEASURES REQUIRED BY THE GRADING PLAN SHALL BE PERFORMED PRIOR TO GRADING, CLEARING OR GRUBBING. ALL EROSION CONTROL DEVICES SUCH AS SILT FENCES, ETC., SHALL BE MAINTAINED IN WORKABLE CONDITION FOR THE LIFE OF THE PROJECT AND SHALL BE REMOVED AT THE COMPLETION OF THE PROJECT ONLY ON THE ENGINEER'S APPROVAL. PAYMENT SHALL BE CONSIDERED INCIDENTAL TO CLEARING AND GRUBBING. IF DURING THE LIFE OF THE PROJECT, A STORM CAUSES SOIL EROSION WHICH CHANGES FINISH GRADES OR CREATES "GULLIES" AND "WASHED AREAS", THESE SHALL BE REPAIRED AT NO EXTRA COST, AND ALL SILT WASHED OFF OF THE PROJECT SITE ONTO ADJACENT PROPERTY SHALL BE REMOVED AS DIRECTED BY THE ENGINEER AT NO EXTRA COST. THE CONTRACTOR SHALL ADHERE TO ANY APPROVED EROSION CONTROL PLANS WHETHER INDICATED IN THE CONSTRUCTION PLANS OR UNDER SEPARATE COVER. 4. DISPOSABLE MATERIAL A. CLEARING AND GRUBBING WASTES SHALL BE REMOVED FROM THE SITE AND PROPERLY DISPOSED OF BY THE CONTRACTOR AT HIS EXPENSE, UNLESS SPECIFIED OTHERWISE. TOPSOIL MAY BE PLACED UP TO 6" IN DEPTH ON SLOPES AND OPEN AREAS IF AVAILABLE WITH PRIOR APPROVAL BY ENGINEER. B. SOLID WASTES TO BE REMOVED SUCH AS SIDEWALKS CURBS PAVEMENT ETC., MAY BE PLACED IN SPECIFIC DISPOSAL AREAS DELINEATED ON THE PLANS OR REMOVED FROM THE SITE AS REQUIRED BY THE SPECIFICATIONS. THIS MATERIAL SHALL HAVE A MINIMUM COVER OF 2'. THE CONTRACTOR SHALL MAINTAIN SPECIFIED COMPACTION REQUIREMENTS IN THESE AREAS. WHEN DISPOSAL SITES ARE NOT PROVIDED, THE CONTRACTOR SHALL REMOVE THIS WASTE FROM THE SITE AND PROPERLY DISPOSE OF IT AT HIS EXPENSE. C. ABANDONED UTILITIES SUCH AS CULVERTS, WATER PIPE, HYDRANTS, CASTINGS, PIPE APPURTENANCES, UTILITY POLES, ETC., SHALL BE THE PROPERTY OF THE SPECIFIC UTILITY AGENCY, OR COMPANY HAVING JURISDICTION. BEFORE THE CONTRACTOR CAN REMOVE, DESTROY, SALVAGE, REUSE, SELL OR STORE FOR HIS OWN USE ANY ABANDONED UTILITY, HE MUST PRESENT TO THE OWNER WRITTEN PERMISSION FROM THE UTILITY INVOLVED. D. ON SITE BURNING IS PROHIBITED. 5. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ADJUSTMENT OF ALL UTILITY SURFACE ACCESSES WHETHER HE PERFORMS THE WORK OR A UTILITY COMPANY PERFORMS THE WORK. 6. THE CONTRACTOR SHALL CONTROL ALL "DUST" BY PERIODIC WATERING AND SHALL PROVIDE ACCESS AT ALL TIMES FOR PROPERTY OWNERS WITHIN THE PROJECT AREA AND FOR EMERGENCY VEHICLES. ALL OPEN DITCHES AND HAZARDOUS AREAS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH THE SPECIFICATIONS. 7. ALL AREAS WHERE THERE IS EXPOSED DIRT SHALL BE SEEDED, FERTILIZED AND MULCHED ACCORDING TO THE SPECIFICATIONS. THE FINISHED SURFACE SHALL BE TO GRADE AND SMOOTH, FREE OF ALL ROCKS LARGER THAN 3", EQUIPMENT TRACKS, DIRT CLODS, BUMPS, RIDGES AND GOUGES PRIOR TO SEEDING; THE SURFACE SHALL BE LOOSENED TO A DEPTH OF t4"-6" TO ACCEPT SEED. THE CONTRACTOR SHALL NOT PROCEED WITH SEEDING OPERATIONS WITHOUT FIRST OBTAINING THE ENGINEER'S APPROVAL OF THE GRADED SURFACE. ALL SEEDING SHALL BE PERFORMED BY A MECHANICAL "HYDRO -SEEDER". HAND SEEDING SHALL BE AUTHORIZED ON AN AREA BY AREA APPROVAL BY THE ENGINEER. DISTURBED AREAS SHOULD THEN BE MATTED WITH SHORT-TERM PHOTODEGRADABLE EROSION CONTROL MATTING. 8. WHERE SPECIFIED, STORM DRAIN PIPE SHALL BE REINFORCED CONCRETE PIPE (RCP) CONFORMING TO AASHTO M-170, AS CONTAINED IN NCDOT STANDARD SPECIFICATION 1032-9 FOR WALL TYPE. WHERE SPECIFIED, ALL STORM DRAIN PIPE SHALL BE HIGH DENSITY POLYETHYLENE (HDPE). SMOOTH WALL INTERIOR, WITH WATER TIGHT JOINTS, BACKFILLED WITH # 57 WASHED STONE UP TO MIN. 6" OVER THE TOP OF THE PIPE. HDPE PIPE USED FOR STORM DRAINAGE DETENTION SYSTEMS SHALL BE ADS N12 WT OR APPROVED EQUAL. 9. CONTRACTOR SHALL VERIFY ALL ELEVATIONS BEFORE INSTALLATION OF FACILITIES. 10. CATCH BASINS CAST -IN-PLACE SHALL CONFORM TO THE REQUIREMENTS OF NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES (LATEST EDITION) ARTICLES 840-1 THROUGH 840-3. CURB INLET CATCH BASIN SHALL CONFORM TO NCDOT STANDARD DETAILS 840.02 THROUGH 840.04. DROP INLETS SHALL CONFORM TO STANDARD DETAIL 840.14. JUNCTION BOXES SHALL CONFORM TO STANDARD DETAIL 840.31. 11. CURB INLET FRAME, GRATE AND HOOD SHALL BE NEENAH R -3233D, PRODUCTS BY DEWEY BROS., U.S. FOUNDRY OR EQUAL. DROP INLET FRAME AND GRATE SHALL BE NEENAH R -3339A OR EQUAL. FIELD INLET COVER SHALL CONFORM TO NCDOT STANDARD DETAIL 840.04, OPENING FACING UPSTREAM. 12. CONCRETE AND MASONRY SHALL MEET THE REQUIREMENTS OF APPROPRIATE SECTION OF NCDOT STANDARD SPECIFICATIONS FOR ROAD AND STRUCTURES (LATEST EDITION). CONCRETE SHALL BE CLASS A OR B, 4000 PSI MINIMUM, MEETING THE REQUIREMENTS OF SECTION 1000, CONSTRUCTED IN ACCORDANCE WITH SECTION 825. MASONRY SHALL MEET THE REQUIREMENTS OF SECTION 1040, CONSTRUCTED IN ACCORDANCE WITH SECTION 830 AND/OR 834. 13. TOPS OF PROPOSED FRAMES AND GRATES SHALL BE FLUSH WITH FINISHED GRADE. 14 NO BASE COURSE SHALL BE PLACED ON MUCK, PIPE, CLAY, ORGANIC MATTER, OR OTHER UNSUITABLE MATTER, AND A MINIMUM COMPACTION RATE OF SUBGRADE PRIOR TO PAVING SHALL NOT BE LESS THAN 95% BY STANDARD PROCTOR METHOD AND CERTIFIED BY A PROFESSIONAL ENGINEER. 15. ALL RETAINING WALLS SHOWN WILL BE DESIGNED BY A LICENSED NORTH CAROLINA PROFESSIONAL ENGINEER PRIOR TO PERMITTING AND CONSTRUCTION OF THE WALL. NOTES: STATEMENT OF PERMIT AND CONTRACTOR RESPONSIBILITIES 1. PROJECT SITE CONTAINS JURISDICTIOANL WATERS OF THE U.S (WOTUS). 2. PROJECT INVOLVES IMPACTS TO WOTUS IN SEVERAL LOCATIONS. 3. PROPOSED IMPACTS TO WOTUS ARE REGULATED BY THE CLEAN WATER ACT SECTIONS 404 AND 401. 4. PERMITS HAVE BEEN OBTAINED BY THE CITY OF XXX INC TO AUTHORIZE THE PROPOSED IMPACTS TO WOTUS AND ARE SUBJECT TO THE TERMS AND CONDITIONS OF THE PERMITS. 5. CWA 404/401 PERMIT REQUIREMENTS, TERMS, AND CONDITIONS ARE SUMMARIZED ON THIS SHEET ALONG WITH VARIOUS ASSOCIATED DETAILS AND SPECIFICATIONS. 6. A COPY OF THE PERMITS HAVE BEEN PROVIDED TO THE CONTRACTOR AT THE PRE -CONSTRUCTION MEETING. THE CONTRACTOR IS RESPONSIBLE FOR READING THE PERMITS, PLANS AND SPECIFICATIONS, AND UNDERSTANDING HIS/HER RESPONSIBILITIES UNDER THE PERMITS, WHICH INCLUDE BUT ARE NOT LIMITED TO: A) COMPLIANCE WITH ALL PERMIT CONDITIONS RELATING TO CONTRACTED CONSTRUCTION ACTIVITIES BOTH ON-SITE AND OFF-SITE, IF OFF-SITE AREAS ARE USED FOR PROJECT RELATED PURPOSES (EG: ACCESS, LAYDOWN, STAGING, BORROW, WASTE, ETC.) B) COMMUNICATION OF PERMIT COMPLIANCE RESPONSIBILITIES TO SUBCONTRACTORS WORKING ON THE PROJECT. C) COORDINATION WITH PROJECT ENGINEER REGARDING PERMIT COMPLIANCE RELATED ISSUES AND QUESTIONS. D) IMMEDIATE REPORTING TO PROJECT ENGINEER OR OWNER OF ANY VIOLATION OR SUSPECTED VIOLATION OF PERMIT CONDITIONS. E) A COPY OF ALL PERMITS AND CONDITIONS SHOULD BE MADE AVAILABLE AT THE PROJECT SITE DURING CONSTRUCTION AND MAINTENANCE ACTIVITIES. Know what's below. 0111 before you dig. N.C. One -Call Center )ial 811 or 1-800-632-4949 NATIONWIDE PERMIT CONDITIONS 1. AQUATIC LIFE MOVEMENTS - NO ACTIVITY MAY SUBSTANTIALLY DISRUPT THE NECESSARY LIFE CYCLE MOVEMENTS OF THOSE SPECIES OF AQUATIC LIFE INDIGENOUS TO THE WATERBODY, INCLUDING THOSE SPECIES THAT NORMALLY MIGRATE THROUGH THE AREA UNLESS THE ACTIVITY'S PRIMARY PURPOSE IS TO IMPOUND WATER. ALL PERMANENT AND TEMPORARY CROSSINGS OF WATERBODIES SHALL BE SUITABLY CULVERTED, BRIDGED, OR OTHERWISE DESIGNED AND CONSTRUCTED TO MAINTAIN LOW FLOWS TO SUSTAIN THE MOVEMENT OF THOSE AQUATIC SPECIES. 2. SUITABLE MATERIAL - NO ACTIVITY MAY USE UNSUITABLE MATERIAL (E.G., TRASH, DEBRIS, CAR BODIES, ASPHALT, ETC.). MATERIAL USED FOR CONSTRUCTION OR DISCHARGED MUST BE FREE FROM TOXIC POLLUTANTS IN TOXIC AMOUNTS (SEE SECTION 307 OF THE CLEAN WATER ACT). 3. MANAGEMENT OF WATER FLOWS - TO THE MAXIMUM EXTENT PRACTICABLE, THE PRE -CONSTRUCTION COURSE, CONDITION, CAPACITY, AND LOCATION OF OPEN WATERS MUST BE MAINTAINED FOR EACH ACTIVITY, INCLUDING STREAM CHANNELIZATION AND STORM WATER MANAGEMENT ACTIVITIES, EXCEPT AS PROVIDED BELOW. THE ACTIVITY MUST BE CONSTRUCTED TO WITHSTAND EXPECTED HIGH FLOWS. THE ACTIVITY MUST NOT RESTRICT OR IMPEDE THE PASSAGE OF NORMAL OR HIGH FLOWS, UNLESS THE PRIMARY PURPOSE OF THE ACTIVITY IS TO IMPOUND WATER OR MANAGE HIGH FLOWS. THE ACTIVITY MAY ALTER THE PRE -CONSTRUCTION COURSE, CONDITION, CAPACITY, AND LOCATION OF OPEN WATERS IF IT BENEFITS THE AQUATIC ENVIRONMENT (E.G., STREAM RESTORATION OR RELOCATION ACTIVITIES). 4. EQUIPMENT - HEAVY EQUIPMENT WORKING IN WETLANDS OR MUDFLATS MUST BE PLACED ON MATS, OR OTHER MEASURES MUST BE TAKEN TO MINIMIZE SOIL DISTURBANCE. 5. SOIL EROSION AND SEDIMENT CONTROLS - APPROPRIATE SOIL EROSION AND SEDIMENT CONTROLS MUST BE USED AND MAINTAINED IN EFFECTIVE OPERATING CONDITION DURING CONSTRUCTION, AND ALL EXPOSED SOIL AND OTHER FILLS, AS WELL AS ANY WORK BELOW THE ORDINARY HIGH WATER MARK OR HIGH TIDE LINE, MUST BE PERMANENTLY STABILIZED AT THE EARLIEST PRACTICABLE DATE. PERMITTEES ARE ENCOURAGED TO PERFORM WORK WITHIN WATERS OF THE UNITED STATES DURING PERIODS OF LOW -FLOW OR NO -FLOW. 6. REMOVAL OF TEMPORARY FILLS - TEMPORARY FILLS MUST BE REMOVED IN THEIR ENTIRETY AND THE AFFECTED AREAS RETURNED TO PRE -CONSTRUCTION ELEVATIONS. THE AFFECTED AREAS MUST BE REVEGETATED, AS APPROPRIATE. 7. PROPER MAINTENANCE - ANY AUTHORIZED STRUCTURE OR FILL SHALL BE PROPERLY MAINTAINED, INCLUDING MAINTENANCE TO ENSURE PUBLIC SAFETY AND COMPLIANCE WITH APPLICABLE NWP GENERAL CONDITIONS, AS WELL AS ANY ACTIVITY -SPECIFIC CONDITIONS ADDED BY THE DISTRICT ENGINEER TO AN NWP AUTHORIZATION. 8. DISCOVERY OF PREVIOUSLY UNKNOWN REMAINS AND ARTIFACTS - IF YOU DISCOVER ANY PREVIOUSLY UNKNOWN HISTORIC, CULTURAL OR ARCHEOLOGICAL REMAINS AND ARTIFACTS WHILE ACCOMPLISHING THE ACTIVITY AUTHORIZED BY THIS PERMIT, YOU MUST IMMEDIATELY NOTIFY THE DISTRICT ENGINEER OF WHAT YOU HAVE FOUND, AND TO THE MAXIMUM EXTENT PRACTICABLE, AVOID CONSTRUCTION ACTIVITIES THAT MAY AFFECT THE REMAINS AND ARTIFACTS UNTIL THE REQUIRED COORDINATION HAS BEEN COMPLETED. THE DISTRICT ENGINEER WILL INITIATE THE FEDERAL, TRIBAL AND STATE COORDINATION REQUIRED TO DETERMINE IF THE ITEMS OR REMAINS WARRANT A RECOVERY EFFORT OR IF THE SITE IS ELIGIBLE FOR LISTING IN THE NATIONAL REGISTER OF HISTORIC PLACES. 9. RESTRICTION ON USE OF LIVE CONCRETE - FOR ALL NWPS WHICH ALLOW THE USE OF CONCRETE AS A BUILDING MATERIAL, LIVE OR FRESH CONCRETE, INCLUDING BAGS OF UNCURED CONCRETE, MAY NOT COME INTO CONTACT WITH THE WATER IN OR ENTERING INTO WATERS OF THE US. WATER INSIDE COFFER DAMS OR CASINGS THAT HAS BEEN IN CONTACT WITH WET CONCRETE SHALL ONLY BE RETURNED TO WATERS OF THE US WHEN IT IS NO LONGER POSES A THREAT TO AQUATIC ORGANISMS. 10. REQUIREMENTS FOR USING RIPRAP FOR BANK STABILIZATION - FOR ALL NWPS THAT ALLOW FOR THE USE OF RIPRAP MATERIAL FOR BANK STABILIZATION, THE FOLLOWING MEASURES SHALL BE APPLIED: 10.1. FILTER CLOTH MUST BE PLACED UNDERNEATH THE RIPRAP AS AN ADDITIONAL REQUIREMENT OF ITS USE IN NORTH CAROLINA WATERS. 10.2. THE PLACEMENT OF RIPRAP SHALL BE LIMITED TO THE AREAS DEPICTED ON SUBMITTED WORK PLAN DRAWINGS. 10.3. THE RIPRAP MATERIAL SHALL BE CLEAN AND FREE FROM LOOSE DIRT OR ANY POLLUTANT EXCEPT IN TRACE QUANTITIES THAT WOULD NOT HAVE AN ADVERSE ENVIRONMENTAL EFFECT. 10.4. IT SHALL BE OF A SIZE SUFFICIENT TO PREVENT ITS MOVEMENT FROM THE AUTHORIZED ALIGNMENT BY NATURAL FORCES UNDER NORMAL CONDITIONS. 10.5. THE RIPRAP MATERIAL SHALL CONSIST OF CLEAN ROCK OR MASONRY MATERIAL SUCH AS, BUT NOT LIMITED TO, GRANITE, MARL, OR BROKEN CONCRETE. 11. SAFE PASSAGE REQUIREMENTS FOR CULVERT PLACEMENT - FOR ALL NWPS THAT INVOLVE THE CONSTRUCTION/INSTALLATION OF CULVERTS, MEASURES WILL BE INCLUDED IN THE CONSTRUCTION/INSTALLATION THAT WILL PROMOTE THE SAFE PASSAGE OF FISH AND OTHER AQUATIC ORGANISMS. THE DIMENSION, PATTERN, AND PROFILE OF THE STREAM ABOVE AND BELOW A PIPE OR CULVERT SHOULD NOT BE MODIFIED BY WIDENING THE STREAM CHANNEL OR BY REDUCING THE DEPTH OF THE STREAM IN CONNECTION WITH THE CONSTRUCTION ACTIVITY. THE WIDTH, HEIGHT, AND GRADIENT OF A PROPOSED CULVERT SHOULD BE SUCH AS TO PASS THE AVERAGE HISTORICAL LOW FLOW AND SPRING FLOW WITHOUT ADVERSELY ALTERING FLOW VELOCITY. SPRING FLOW SHOULD BE DETERMINED FROM GAGE DATA, IF AVAILABLE. IN THE ABSENCE OF SUCH DATA, BANKFULL FLOW CAN BE USED AS A COMPARABLE LEVEL. EXISTING CONDITIONS LEGEND NCDEQ GENERAL CONSTRUCTION CONDITIONS 1. THE CONTRACTOR SHALL MINIMIZE CLEARING WITHIN WETLANDS AND ACROSS STREAMS TO THE GREATEST EXTENT PRACTICABLE AND SHALL NOT EXCEED 50' WIDE FOR GAS UTILITY LINES AND 40' WIDE FOR ALL OTHER UTILITY LINES. EXCEPTIONS TO THIS CONDITION WILL REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. FOR CONSTRUCTION CORRIDORS IN WETLANDS AND ACROSS STREAM CHANNELS, STUMPS SHALL BE GRUBBED ONLY AS NEEDED TO INSTALL THE UTILITY AND REMAINING STUMPS SHALL BE CUT OFF AT GRADE LEVEL. THE GENERAL STRIPPING OF TOPSOIL WITHIN WETLANDS ALONG THE CONSTRUCTION CORRIDOR IS NOT PERMITTED. 2. PERMANENT MAINTAINED ACCESS CORRIDORS IN WETLANDS AND ACROSS STREAM CHANNELS SHALL BE RESTRICTED TO THE MINIMUM WIDTH PRACTICABLE AND SHALL NOT EXCEED 30' WIDE FOR GAS UTILITY LINES AND 20' WIDE FOR ALL OTHER UTILITY LINES EXCEPT AT MANHOLE LOCATIONS. 15' X 15' PERPENDICULAR VEHICLE TURN-AROUNDS ARE ALLOWED IN ACCESS CORRIDORS BUT MUST BE SPACED AT LEAST 500' APART. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 3. THE CONTRACTOR SHALL HAVE A SPECIFIC PLAN FOR RESTORING WETLAND CONTOURS. ANY EXCESS MATERIAL SHALL BE REMOVED TO A HIGH GROUND DISPOSAL AREA. THE MIXING OF TOPSOIL AND SUBSOILS WITHIN WETLANDS ALONG UTILITY CORRIDORS SHALL BE MINIMIZED TO THE GREATEST EXTENT PRACTICABLE DURING EXCAVATION. THE SOILS SHALL BE PLACED ON FABRIC TO MINIMIZE IMPACTS WHENEVER POSSIBLE. TOPSOIL EXCAVATED FROM UTILITY TRENCHES SHALL BE PILED SEPARATELY FROM SUBSOILS AND BACKFILLED INTO THE TRENCH ONLY AFTER THE SUBSOILS HAVE BEEN PLACED AND COMPACTED. 4. NO WASTE, SPOIL, SOLIDS, OR FILL OF ANY KIND CAN OCCUR IN WETLANDS OR WATERS BEYOND THE FOOTPRINT OF THE IMPACT AREA (INCLUDING TEMPORARY IMPACTS) OR BEYOND THE PERMITTED THRESHOLDS WITHOUT WRITTEN AUTHORIZATION FROM THE PROJECT ENGINEER. NO REMOVAL OF VEGETATION OR OTHER IMPACTS OF ANY KIND CAN OCCUR TO STATE REGULATED RIPARIAN BUFFERS BEYOND THE FOOTPRINT OF IMPACTS APPROVED IN A BUFFER AUTHORIZATION OR VARIANCE OR AS LISTED AS AN EXEMPT ACTIVITY IN THE APPLICABLE RIPARIAN BUFFER RULES. 5. ALL EROSION CONTROL DEVICES SHALL BE MAINTAINED ON ALL CONSTRUCTION SITES, BORROW SITES, AND WASTE PILE (SPOIL) SITES, INCLUDING CONTRACTOR OWNED OR LEASED BORROW PITS ASSOCIATED WITH THE PROJECT. SUFFICIENT MATERIALS REQUIRED FOR STABILIZATION AND/OR REPAIR OF EROSION CONTROL MEASURES AND STORMWATER ROUTING AND TREATMENT SHALL BE ON-SITE AT ALL TIMES. 6. SEDIMENT AND EROSION CONTROL MEASURES SHALL NOT BE PLACED IN WETLANDS OR WATERS EXCEPT WITHIN THE FOOTPRINT OF TEMPORARY OR PERMANENT IMPACTS AUTHORIZED UNDER THE PERMITS. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 7. EROSION CONTROL MATTING THAT INCORPORATES PLASTIC MESH AND/OR PLASTIC TWINE SHALL NOT BE USED ALONG STREAMBANKS OR WITHIN WETLANDS. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 8. AN NPDES CONSTRUCTION STORMWATER PERMIT (NCGO10000) IS REQUIRED FOR CONSTRUCTION PROJECTS THAT DISTURB ONE OR MORE ACRES OF LAND. THE NCGO10000 PERMIT ALLOWS STORMWATER TO BE DISCHARGED DURING LAND DISTURBING CONSTRUCTION ACTIVITIES AS STIPULATED IN THE CONDITIONS OF THE PERMIT. IF THE PROJECT IS COVERED BY THE PERMITS, FULL COMPLIANCE WITH PERMIT CONDITIONS INCLUDING THE EROSION AND SEDIMENTATION CONTROL PLAN, INSPECTIONS AND MAINTENANCE, SELF-MONITORING, RECORD KEEPING AND REPORTING REQUIREMENTS IS REQUIRED. 9. ALL WORK IN OR ADJACENT TO STREAMS SHALL BE CONDUCTED SO THAT THE FLOWING STREAM DOES NOT COME IN CONTACT WITH THE DISTURBED AREA. APPROVED BEST MANAGEMENT PRACTICES FROM THE MOST CURRENT VERSION OF THE INC SEDIMENT AND EROSION CONTROL MANUAL, OR THE NC DOT CONSTRUCTION AND MAINTENANCE ACTIVITIES MANUAL, SUCH AS SANDBAGS, ROCK BERMS, COFFERDAMS, AND OTHER DIVERSION STRUCTURES SHALL BE USED TO MINIMIZE EXCAVATION IN FLOWING WATER. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 10. CULVERTS SHALL BE INSTALLED IN SUCH A MANNER THAT THE ORIGINAL STREAM PROFILES ARE NOT ALTERED AND ALLOW FOR AQUATIC LIFE MOVEMENT DURING LOW FLOWS. THE DIMENSION PATTERN AND PROFILE OF THE STREAM ABOVE AND BELOW A PIPE OR CULVERT SHALL NOT BE MODIFIED BY WIDENING THE STREAM CHANNEL OR BY REDUCING THE DEPTH OF THE STREAM IN CONNECTION WITH THE CONSTRUCTION ACTIVITY. 11. APPLICATION OF FERTILIZER TO ESTABLISH PLANTED/SEEDED VEGETATION WITHIN DISTURBED RIPARIAN AREAS SHALL COMPLY WITH ALL OTHER FEDERAL, STATE AND LOCAL REGULATIONS. FERTILIZER APPLICATION SHALL BE ACCOMPLISHED IN A MANNER THAT MINIMIZES THE RISK OF CONTACT BETWEEN THE FERTILIZER AND SURFACE WATERS. 12. IF CONCRETE IS USED DURING CONSTRUCTION, THEN ALL NECESSARY MEASURES SHALL BE TAKEN TO PREVENT DIRECT CONTACT BETWEEN UNCURED OR CURING CONCRETE AND WATERS OF THE US. WATER THAT INADVERTENTLY CONTACTS UNCURED CONCRETE SHALL NOT BE DISCHARGED TO WATERS OF THE US. 13. ALL PROPOSED AND APPROVED TEMPORARY FILL AND CULVERTS SHALL BE REMOVED AND THE IMPACTED AREA RETURNED TO NATURAL CONDITIONS WITHIN 60 CALENDAR DAYS AFTER THE TEMPORARY IMPACT IS NO LONGER NECESSARY. THE IMPACTED AREAS SHALL BE RETURNED TO ORIGINAL GRADE, INCLUDING EACH STREAM'S ORIGINAL CROSS SECTIONAL DIMENSIONS, PLANFORM PATTERN, AND LONGITUDINAL BED PROFILE. ALL TEMPORARY IMPACTS SHALL BE RESTORED AND STABILIZED WITH NATIVE VEGETATION. 14. ALL PROPOSED AND APPROVED TEMPORARY PIPES/CULVERTS/RIP-RAP PADS ETC. IN STREAMS SHALL BE INSTALLED AS OUTLINED IN THE MOST RECENT EDITION OF THE NC SEDIMENT AND EROSION CONTROL PLANNING AND DESIGN MANUAL OR THE NCDOT BEST MANAGEMENT PRACTICES FOR CONSTRUCTION AND MAINTENANCE ACTIVITIES SO AS NOT TO RESTRICT STREAM FLOW OR CAUSE DIS -EQUILIBRIUM DURING USE OF THIS CERTIFICATION. 15. ANY RIP -RAP REQUIRED FOR PROPER CULVERT PLACEMENT, STREAM STABILIZATION, OR RESTORATION OF TEMPORARILY DISTURBED AREAS SHALL BE RESTRICTED TO THE AREA DIRECTLY IMPACTED BY THE APPROVED CONSTRUCTION ACTIVITY. ALL RIP -RAP SHALL BE PLACED SUCH THAT THE ORIGINAL STREAM ELEVATION AND STREAM BANK CONTOURS ARE RESTORED AND MAINTAINED, NOT RESULT IN THE DE -STABILIZATION OF STREAM BED OR BANKS UPSTREAM OR DOWNSTREAM OF THE AREA, AND NOT RESTRICT AQUATIC LIFE PASSAGE. 16. ANY RIP -RAP USED FOR STREAM OR SHORELINE STABILIZATION SHALL BE OF SIZE AND DENSITY TO PREVENT MOVEMENT BY WAVE, CURRENT, OR STREAM FLOWS, AND WILL CONSIST OF CLEAN ROCK OR MASONRY MATERIAL. RIP -RAP SHALL NOT BE INSTALLED IN THE STREAMBED EXCEPT IN SPECIFIC AREAS REQUIRED FOR VELOCITY CONTROL AND TO ENSURE STRUCTURAL INTEGRITY OF BANK STABILIZATION MEASURES. 17. ALL MECHANIZED EQUIPMENT OPERATED NEAR SURFACE WATERS SHALL BE INSPECTED, FUELED, LUBRICATED, AND MAINTAINED REGULARLY AND MAINTENANCE PERFORMED IN A MANNER TO PREVENT CONTAMINATION OF STREAM WATER FROM FUELS, LUBRICANTS, HYDRAULIC FLUIDS, OR OTHER TOXIC MATERIALS. 18. HEAVY EQUIPMENT WORKING IN WETLANDS SHALL BE PLACED ON MATS OR OTHER MEASURES TAKEN TO MINIMIZE SOIL DISTURBANCE. 19. THE CONTRACTOR OR OTHER RESPONSIBLE ENTITY SHALL REPORT ANY PETROLEUM SPILL OF 25 GALLONS OR MORE; ANY SPILL REGARDLESS OF AMOUNT THAT CAUSES A SHEEN ON SURFACE WATERS; ANY PETROLEUM SPILL REGARDLESS OF SIZE THAT OCCURS WITHIN 100 -FEET OF SURFACE WATER; AND ANY PETROLEUM SPILL LESS THAN 25 GALLONS THAT CANNOT BE CLEANED UP WITHIN 24 HOURS. -o-o-o-o-o-o-o-o-o-o-o-o-o-o- TEL PED TELEPHONE PEDESTAL 12. IN THE TWENTY(20)COUNTIES OF NORTH CAROLINA DESIGNATED AS COASTAL COUNTIES BY THE �ELEC PED ELECTRIC PEDESTAL COASTAL AREA MANAGEMENT ACT (CAMA): ALL PIPES/CULVERTS MUST BE SUFFICIENTLY SIZED TO CATV CABLE TV PEDESTAL ALLOW FOR THE BURIAL OF THE BOTTOM OF THE PIPE/CULVERT AT LEAST ONE FOOT BELOW PED RIGHT OF WAY NORMAL BED ELEVATION WHEN THEY ARE PLACED WITHIN THE PUBLIC TRUST AREA OF SIGN SIGN ENVIRONMENTAL CONCERN (AEC) AND/OR THE ESTUARINE WATERS AEC AS DESIGNATED BY CAMA, CATV UNDERGROUND CABLE TV SIGN AND/OR ALL STREAMS APPEARING AS BLUE LINES ON UNITED STATES GEOLOGICAL SURVEY (USGS) CALCULATED POINT PB 7.5 -MINUTE QUADRANGLE MAPS. IN ALL OTHER COUNTIES: CULVERTS GREATER THAN 48 INCHES UG FOG UNDERGROUND FIBER OPTIC CABLE SIGN IN DIAMETER WILL BE BURIED AT LEAST ONE FOOT BELOW THE BED OF THE STREAM. CULVERTS 48 �UG TCS UNDERGROUND TELEPHONE CABLE SIGN INCHES IN DIAMETER OR LESS SHALL BE BURIED OR PLACED ON THE STREAM BED AS �UG GAS UNDERGROUND GAS LINE SIGN PRACTICABLE AND APPROPRIATE TO MAINTAIN AQUATIC PASSAGE, AND EVERY EFFORT SHALL BE I I I DL-- L----CTV-----CTV- I I I I MADE TO MAINTAIN THE EXISTING CHANNEL SLOPE. THE BOTTOM OF THE CULVERT MUST BE �UG ELEC UNDERGROUND ELECTRIC LINE SIGN PLACED AT A 27 DEPTH BELOW THE NATURAL STREAM BOTTOM TO PROVIDE FOR PASSAGE DURING - - CTV- DROUGHT OR LOW FLOW CONDITIONS. LP LIGHT POLE 13. CULVERTS PLACED WITHIN RIPARIAN AND/OR RIVERINE WETLANDS MUST BE INSTALLED IN A OUP UTILITY POLE MANNER THAT DOES NOT RESTRICT THE FLOW AND CIRCULATION PATTERNS OF WATERS OF THE I I GUY WIRE ANCHOR UNITED STATES. CULVERTS PLACED ACROSS WETLAND FILLS PURELY FOR THE PURPOSES OF ®TSP TRAFFIC SIGNAL POLE EQUALIZING SURFACE WATER DO NOT HAVE TO BE BURIED. RXR RAILROAD CROSSING SIGNAL 14. PIPELINE/UTILITY LINE CONSTRUCTION THROUGH JURISDICTIONAL WATERS AND WETLANDS WILL BE o ACCOMPLISHED UTILIZING DIRECTIONAL DRILLING/BORING METHODS TO THE MAXIMUM EXTENT O MH MANHOLE PRACTICABLE. Q SSMH SANITARY SEWER MANHOLE 15. TEMPORARY DISCHARGE OF EXCAVATED OR FILL MATERIAL INTO WETLANDS AND WATERS OF THE ° OSDMH STORM DRAIN MANHOLE UNITED STATES WILL BE FOR THE ABSOLUTE MINIMUM PERIOD OF TIME NECESSARY TO ACCOMPLISH Q COMMH COMMUNICATION MANHOLE THE WORK. TEMPORARY DISCHARGES WILL BE FULLY CONTAINED WITH APPROPRIATE EROSION CONTROL OR CONTAINMENT METHODS OR OTHERWISE SUCH FILLS WILL CONSIST OF NON -ERODIBLE O ELMH ELECTRICAL MANHOLE MATERIALS. O ° J.B. JUNCTION BOX 16. THE WORK AREA AUTHORIZED BY THIS PERMIT, INCLUDING TEMPORARY AND/OR PERMANENT FILLS, SPIGOT SPIGOT/YARD HYDRANT WILL BE MINIMIZED TO THE GREATEST EXTENT PRACTICABLE. JUSTIFICATION FOR WORK CORRIDORS x EXCEEDING FORTY (40) FEET IN WIDTH IS REQUIRED AND WILL BE BASED ON PIPELINE DIAMETER O C.O. SEWER CLEAN-OUT AND LENGTH, SIZE OF EQUIPMENT REQUIRED TO CONSTRUCT THE UTILITY LINE, AND OTHER 0 E.SS ELECTRIC SERVICE STUB -OUT CONSTRUCTION INFORMATION DEEMED NECESSARY TO SUPPORT THE REQUEST. THE APPLICANT IS W REQUIRED TO PROVIDE THIS INFORMATION TO THE CORPS WITH THE INITIAL NOTIFICATION PACKAGE. 0 G.SS GAS SERVICE STUB -OUT 17. IN AREAS WHERE A SUB AQUEOUS UTILITY LINE IS TO CROSS A FEDERALLY MAINTAINED CHANNEL, ®CB CATCH BASIN (I.E., THE ATLANTIC INTRACOASTAL WATERWAY [AIWW]), THE LINE WILL BE BURIED AT LEAST SIX I --I rn (6) FEET BELOW THE ALLOWABLE OVERDEPTH OF THE AUTHORIZED CHANNEL, INCLUDING ALL SIDE ®cl CURB INLET SLOPES. FOR AREAS OUTSIDE FEDERALLY -MAINTAINED CHANNELS, SUB -AQUEOUS LINES MUST BE OWM WATER METER INSTALLED AT A MINIMUM DEPTH OF TWO (2) FEET BELOW THE SUBSTRATE WHEN SUCH LINES QFH FIRE HYDRANT MIGHT INTERFERE WITH NAVIGATION. w >a WV WATER VALVE 18. FOR THE PURPOSES OF THIS NWP ANY PERMANENTLY MAINTAINED CORRIDOR ALONG THE UTILITY BLOWOFF ROW WITHIN FORESTED WETLANDS SHALL BE CONSIDERED A PERMANENT IMPACT ANDA VALVE BLOW OFF VALVE COMPENSATORY MITIGATION PLAN WILL BE REQUIRED FOR ALL SUCH IMPACTS ASSOCIATED WITH b G/M GAS METER THE REQUESTED ACTIVITY. b G/V GAS VALVE 19. USE OF RIP -RAP OR ANY OTHER ENGINEERED STRUCTURES TO STABILIZE A STREAM BED SHOULD BE AVOIDED TO THE MAXIMUM EXTENT PRACTICABLE. IF RIPRAP STABILIZATION IS NEEDED, IT D -a IcV IRRIGATION CONTROL VALVE SHOULD BE PLACED ONLY ON THE STREAM BANKS, OR, IF IT IS NECESSARY TO BE PLACED IN C>a PIV POST INDICATOR VALVE THE STREAM BED, THE FINISHED TOP ELEVATION OF THE RIPRAP SHOULD NOT EXCEED THAT OF THE ORIGINAL STREAM BED ® E.JUNC ELECTRIC JUNCTION BOX OR OUTLET 20. WHEN DIRECTIONAL BORING OR HORIZONTAL DIRECTIONAL DRILLING (HDD) UNDER WATERS OF THE o TRAFFIC SIGNAL BOX U.S., INCLUDING WETLANDS, PERMITTEES SHALL CLOSELY MONITOR THE PROJECT FOR HYDRAULIC BSIG ox FRACTURING OR `TRACKING." ANY DISCHARGE FROM HYDRAULIC FRACTURING OR `TRACKING" INTO WATERS OF THE U.S., INCLUDING WETLANDS, SHALL BE REPORTED TO THE APPROPRIATE CORPS REGULATORY FIELD OFFICE WITHIN 48 HOURS. RESTORATION AND/OR MITIGATION MAY BE REQUIRED AS A RESULT FROM ANY UNINTENDED DISCHARGES. x x x NCDEQ GENERAL CONSTRUCTION CONDITIONS 1. THE CONTRACTOR SHALL MINIMIZE CLEARING WITHIN WETLANDS AND ACROSS STREAMS TO THE GREATEST EXTENT PRACTICABLE AND SHALL NOT EXCEED 50' WIDE FOR GAS UTILITY LINES AND 40' WIDE FOR ALL OTHER UTILITY LINES. EXCEPTIONS TO THIS CONDITION WILL REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. FOR CONSTRUCTION CORRIDORS IN WETLANDS AND ACROSS STREAM CHANNELS, STUMPS SHALL BE GRUBBED ONLY AS NEEDED TO INSTALL THE UTILITY AND REMAINING STUMPS SHALL BE CUT OFF AT GRADE LEVEL. THE GENERAL STRIPPING OF TOPSOIL WITHIN WETLANDS ALONG THE CONSTRUCTION CORRIDOR IS NOT PERMITTED. 2. PERMANENT MAINTAINED ACCESS CORRIDORS IN WETLANDS AND ACROSS STREAM CHANNELS SHALL BE RESTRICTED TO THE MINIMUM WIDTH PRACTICABLE AND SHALL NOT EXCEED 30' WIDE FOR GAS UTILITY LINES AND 20' WIDE FOR ALL OTHER UTILITY LINES EXCEPT AT MANHOLE LOCATIONS. 15' X 15' PERPENDICULAR VEHICLE TURN-AROUNDS ARE ALLOWED IN ACCESS CORRIDORS BUT MUST BE SPACED AT LEAST 500' APART. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 3. THE CONTRACTOR SHALL HAVE A SPECIFIC PLAN FOR RESTORING WETLAND CONTOURS. ANY EXCESS MATERIAL SHALL BE REMOVED TO A HIGH GROUND DISPOSAL AREA. THE MIXING OF TOPSOIL AND SUBSOILS WITHIN WETLANDS ALONG UTILITY CORRIDORS SHALL BE MINIMIZED TO THE GREATEST EXTENT PRACTICABLE DURING EXCAVATION. THE SOILS SHALL BE PLACED ON FABRIC TO MINIMIZE IMPACTS WHENEVER POSSIBLE. TOPSOIL EXCAVATED FROM UTILITY TRENCHES SHALL BE PILED SEPARATELY FROM SUBSOILS AND BACKFILLED INTO THE TRENCH ONLY AFTER THE SUBSOILS HAVE BEEN PLACED AND COMPACTED. 4. NO WASTE, SPOIL, SOLIDS, OR FILL OF ANY KIND CAN OCCUR IN WETLANDS OR WATERS BEYOND THE FOOTPRINT OF THE IMPACT AREA (INCLUDING TEMPORARY IMPACTS) OR BEYOND THE PERMITTED THRESHOLDS WITHOUT WRITTEN AUTHORIZATION FROM THE PROJECT ENGINEER. NO REMOVAL OF VEGETATION OR OTHER IMPACTS OF ANY KIND CAN OCCUR TO STATE REGULATED RIPARIAN BUFFERS BEYOND THE FOOTPRINT OF IMPACTS APPROVED IN A BUFFER AUTHORIZATION OR VARIANCE OR AS LISTED AS AN EXEMPT ACTIVITY IN THE APPLICABLE RIPARIAN BUFFER RULES. 5. ALL EROSION CONTROL DEVICES SHALL BE MAINTAINED ON ALL CONSTRUCTION SITES, BORROW SITES, AND WASTE PILE (SPOIL) SITES, INCLUDING CONTRACTOR OWNED OR LEASED BORROW PITS ASSOCIATED WITH THE PROJECT. SUFFICIENT MATERIALS REQUIRED FOR STABILIZATION AND/OR REPAIR OF EROSION CONTROL MEASURES AND STORMWATER ROUTING AND TREATMENT SHALL BE ON-SITE AT ALL TIMES. 6. SEDIMENT AND EROSION CONTROL MEASURES SHALL NOT BE PLACED IN WETLANDS OR WATERS EXCEPT WITHIN THE FOOTPRINT OF TEMPORARY OR PERMANENT IMPACTS AUTHORIZED UNDER THE PERMITS. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 7. EROSION CONTROL MATTING THAT INCORPORATES PLASTIC MESH AND/OR PLASTIC TWINE SHALL NOT BE USED ALONG STREAMBANKS OR WITHIN WETLANDS. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 8. AN NPDES CONSTRUCTION STORMWATER PERMIT (NCGO10000) IS REQUIRED FOR CONSTRUCTION PROJECTS THAT DISTURB ONE OR MORE ACRES OF LAND. THE NCGO10000 PERMIT ALLOWS STORMWATER TO BE DISCHARGED DURING LAND DISTURBING CONSTRUCTION ACTIVITIES AS STIPULATED IN THE CONDITIONS OF THE PERMIT. IF THE PROJECT IS COVERED BY THE PERMITS, FULL COMPLIANCE WITH PERMIT CONDITIONS INCLUDING THE EROSION AND SEDIMENTATION CONTROL PLAN, INSPECTIONS AND MAINTENANCE, SELF-MONITORING, RECORD KEEPING AND REPORTING REQUIREMENTS IS REQUIRED. 9. ALL WORK IN OR ADJACENT TO STREAMS SHALL BE CONDUCTED SO THAT THE FLOWING STREAM DOES NOT COME IN CONTACT WITH THE DISTURBED AREA. APPROVED BEST MANAGEMENT PRACTICES FROM THE MOST CURRENT VERSION OF THE INC SEDIMENT AND EROSION CONTROL MANUAL, OR THE NC DOT CONSTRUCTION AND MAINTENANCE ACTIVITIES MANUAL, SUCH AS SANDBAGS, ROCK BERMS, COFFERDAMS, AND OTHER DIVERSION STRUCTURES SHALL BE USED TO MINIMIZE EXCAVATION IN FLOWING WATER. EXCEPTIONS TO THIS CONDITION REQUIRE WRITTEN APPROVAL FROM THE PROJECT ENGINEER. 10. CULVERTS SHALL BE INSTALLED IN SUCH A MANNER THAT THE ORIGINAL STREAM PROFILES ARE NOT ALTERED AND ALLOW FOR AQUATIC LIFE MOVEMENT DURING LOW FLOWS. THE DIMENSION PATTERN AND PROFILE OF THE STREAM ABOVE AND BELOW A PIPE OR CULVERT SHALL NOT BE MODIFIED BY WIDENING THE STREAM CHANNEL OR BY REDUCING THE DEPTH OF THE STREAM IN CONNECTION WITH THE CONSTRUCTION ACTIVITY. 11. APPLICATION OF FERTILIZER TO ESTABLISH PLANTED/SEEDED VEGETATION WITHIN DISTURBED RIPARIAN AREAS SHALL COMPLY WITH ALL OTHER FEDERAL, STATE AND LOCAL REGULATIONS. FERTILIZER APPLICATION SHALL BE ACCOMPLISHED IN A MANNER THAT MINIMIZES THE RISK OF CONTACT BETWEEN THE FERTILIZER AND SURFACE WATERS. 12. IF CONCRETE IS USED DURING CONSTRUCTION, THEN ALL NECESSARY MEASURES SHALL BE TAKEN TO PREVENT DIRECT CONTACT BETWEEN UNCURED OR CURING CONCRETE AND WATERS OF THE US. WATER THAT INADVERTENTLY CONTACTS UNCURED CONCRETE SHALL NOT BE DISCHARGED TO WATERS OF THE US. 13. ALL PROPOSED AND APPROVED TEMPORARY FILL AND CULVERTS SHALL BE REMOVED AND THE IMPACTED AREA RETURNED TO NATURAL CONDITIONS WITHIN 60 CALENDAR DAYS AFTER THE TEMPORARY IMPACT IS NO LONGER NECESSARY. THE IMPACTED AREAS SHALL BE RETURNED TO ORIGINAL GRADE, INCLUDING EACH STREAM'S ORIGINAL CROSS SECTIONAL DIMENSIONS, PLANFORM PATTERN, AND LONGITUDINAL BED PROFILE. ALL TEMPORARY IMPACTS SHALL BE RESTORED AND STABILIZED WITH NATIVE VEGETATION. 14. ALL PROPOSED AND APPROVED TEMPORARY PIPES/CULVERTS/RIP-RAP PADS ETC. IN STREAMS SHALL BE INSTALLED AS OUTLINED IN THE MOST RECENT EDITION OF THE NC SEDIMENT AND EROSION CONTROL PLANNING AND DESIGN MANUAL OR THE NCDOT BEST MANAGEMENT PRACTICES FOR CONSTRUCTION AND MAINTENANCE ACTIVITIES SO AS NOT TO RESTRICT STREAM FLOW OR CAUSE DIS -EQUILIBRIUM DURING USE OF THIS CERTIFICATION. 15. ANY RIP -RAP REQUIRED FOR PROPER CULVERT PLACEMENT, STREAM STABILIZATION, OR RESTORATION OF TEMPORARILY DISTURBED AREAS SHALL BE RESTRICTED TO THE AREA DIRECTLY IMPACTED BY THE APPROVED CONSTRUCTION ACTIVITY. ALL RIP -RAP SHALL BE PLACED SUCH THAT THE ORIGINAL STREAM ELEVATION AND STREAM BANK CONTOURS ARE RESTORED AND MAINTAINED, NOT RESULT IN THE DE -STABILIZATION OF STREAM BED OR BANKS UPSTREAM OR DOWNSTREAM OF THE AREA, AND NOT RESTRICT AQUATIC LIFE PASSAGE. 16. ANY RIP -RAP USED FOR STREAM OR SHORELINE STABILIZATION SHALL BE OF SIZE AND DENSITY TO PREVENT MOVEMENT BY WAVE, CURRENT, OR STREAM FLOWS, AND WILL CONSIST OF CLEAN ROCK OR MASONRY MATERIAL. RIP -RAP SHALL NOT BE INSTALLED IN THE STREAMBED EXCEPT IN SPECIFIC AREAS REQUIRED FOR VELOCITY CONTROL AND TO ENSURE STRUCTURAL INTEGRITY OF BANK STABILIZATION MEASURES. 17. ALL MECHANIZED EQUIPMENT OPERATED NEAR SURFACE WATERS SHALL BE INSPECTED, FUELED, LUBRICATED, AND MAINTAINED REGULARLY AND MAINTENANCE PERFORMED IN A MANNER TO PREVENT CONTAMINATION OF STREAM WATER FROM FUELS, LUBRICANTS, HYDRAULIC FLUIDS, OR OTHER TOXIC MATERIALS. 18. HEAVY EQUIPMENT WORKING IN WETLANDS SHALL BE PLACED ON MATS OR OTHER MEASURES TAKEN TO MINIMIZE SOIL DISTURBANCE. 19. THE CONTRACTOR OR OTHER RESPONSIBLE ENTITY SHALL REPORT ANY PETROLEUM SPILL OF 25 GALLONS OR MORE; ANY SPILL REGARDLESS OF AMOUNT THAT CAUSES A SHEEN ON SURFACE WATERS; ANY PETROLEUM SPILL REGARDLESS OF SIZE THAT OCCURS WITHIN 100 -FEET OF SURFACE WATER; AND ANY PETROLEUM SPILL LESS THAN 25 GALLONS THAT CANNOT BE CLEANED UP WITHIN 24 HOURS. -o-o-o-o-o-o-o-o-o-o-o-o-o-o- IRON PIN SET RBF REBAR FOUND OTIPF OPEN TOP IRON PIN FOUND CTIPF ----s-----s CMU CONCRETE MASONRY UNIT R/W RIGHT OF WAY CL CENTERLINE ----w-----w CURVE (SEE CURVE TABLE) POB POINT OF BEGINNING CP CALCULATED POINT PB I I I I I I I I I I I I I I I I I I I I I -----G-----G- I I I I I I I -- DL----- I I I I I I DL----- I I I I I I DL-- L----CTV-----CTV- I I I I CONCRETE - -CTV - - - - - CTV- 0 U CTV CTV v O U U) 0 U) -----FOC-----FOC- OQ O 006 o ----E-----E 0. �O Z U _ E z vJ w E ----T-----T I ---I > -T- -T- -----ROW -----ROW0000000000 - u U IPS IRON PIN SET RBF REBAR FOUND OTIPF OPEN TOP IRON PIN FOUND CTIPF CRIMPED TOP IRON PIN FOUND CMU CONCRETE MASONRY UNIT R/W RIGHT OF WAY CL CENTERLINE C CURVE (SEE CURVE TABLE) POB POINT OF BEGINNING CP CALCULATED POINT PB PLAT BOOK DB DEED BOOK L LINE (SEE LINE TABLE) BLDG BUILDING CIP CAST IRON PIPE CMP CORRUGATED METAL PIPE CONC CONCRETE NO. I DATE I BY 0 CALCULATED POINT GIPS 1/2" REBAR SET WITH CAP ® CONCRETE MONUMENT ®CM-R/W RIGHT-OF-WAY MONUMENT ODOT MON D.O.T. CONTROL POINT 0RBF REBAR FOUND ORRSPIKE RAILROAD SPIKE o PK NL PK NAIL FOUND / SET SPINDLE SPINDLE FOUND / SET ®CPHUB HUB & TACK SET ACP/NL GPS CONTROL POINT NAIL SET / FOUND OCP/NL CONTROL POINT/NAIL SET GPS OCP/TEMP CONTROL POINT TEMPORARY MARK * NGS METAL ROD NATIONAL GEODETIC SURVEY METAL ROD ® NGS CM NATIONAL GEODETIC SURVEY CONCRETE MONUMENT NGS TEMPORARY CONTROL POINT SET ® NETWORK TRIANGULATION POINT ASTAKE STAKE FOUND 7 40 INTERSTATE HIGHWAY 66 U.S. HIGHWAY } FFE -7-ELEVATIONFINISHED FLOOR ELEVATION e Mw MONITORING WELL OPZ PIEZOMETER ® LANDFILL GAS MONITORING PROBE O SURFACE WATER SAMPLING LOCATION LANDFILL GAS VENT 0 LANDFILL GAS COLLECTION WELLHEAD Qw POTABLE WATER WELL OMB MAILBOX OR PAPER BOX ❑PB POSTAL DROP BOX .)SAT DISH SATELLITE DISH OYARD ORNAMENT STATUE, BIRD BATHS, ETC. TREES 0 SHRUBS / BUSHES (H) HORIZONTAL GROUND DISTANCE (G) NC STATE PLANE GRID DISTANCE CULVERT FENCE SILT FENCE GUARD RAIL APPROXIMATE LOCATION OF EXISTING SEWER LINES APPROXIMATE LOCATION OF EXISTING WATER LINES APPROXIMATE LOCATION OF EXISTING GAS LINES TOP OF SLOPE TOE OF SLOPE DITCH LINES APPROXIMATE LOCATION OF UNDERGROUND CABLE TV LINE APPROXIMATE LOCATION OF OVERHEAD CABLE TV LINE APPROXIMATE LOCATION OF UNDERGROUND FIBER OPTIC CABLE LINE APPROXIMATE LOCATION OF UNDERGROUND ELECTRIC LINE APPROXIMATE LOCATION OF OVERHEAD ELECTRIC LINE APPROXIMATE LOCATION OF UNDERGROUND TELEPHONE LINES APPROXIMATE LOCATION OF OVERHEAD TELEPHONE LINES RIGHT-OF-WAY TREELINE SHRUBLINE PROPERTY LINE NOT SURVEYED ROCKLINE STREAM LINE CENTERLINE CENTERLINE VARIANT SWAM PLINE/WETLANDS APPROXIMATE LOCATION OF OVERHEAD UTILITY LINE CMU CONCRETE MASONRY UNIT CPP CORRUGATED PLASTIC PIPE DIP DUCTILE IRON PIPE E&T ELECTRIC & TELEPHONE FOC FIBER OPTIC CABLE GIP GALVANIZED IRON PIPE 0/H OVERHEAD RCP REINFORCED CONCRETE PIPE U/G UNDERGROUND VCP VITRIFIED CLAY PIPE PVC POLYVINYL CHLORIDE PIPE FFE FINISHED FLOOR ELEVATION PG PAGE REF REFERENCE DOT DEPARTMENT OF TRANSPORTATION NGS NATIONAL GEODETIC SYRVEY NCSP NORTH CAROLINA STATE PLANE MTR BOX METER BOX REVISION DESCRIPTION �wC71, U Q z Z U� 00 � J WZ� W �z O� >0U W U 00 O W VJ (D= O 0 H � o �/J U)v Q Z 0 U c� v O U U) 0 U) Z OQ O 006 o 0. �O Z U _ � z vJ w I ---I > x w wE-� W z I --I rn Q AF11`J w CD CD N 06 LU in Q > >CO L � � LU LU g ~ � z m z Q CO -0 z uj C7 p C� C!) z = mO Q w Q w O w C6= � p p U p U E= Cn 0 Z V J W0 Ow Z (D W N< J ry W Z rW V SHEET G-002 U Q z Z J 00 � J W 0 O� >0U 00 O W VJ (D= O 0 'Z U)� � II.I.- �/J U)v Q Z 0 U Up O U U) 0 U) Z OQ O 006 cn 0. �O Z w Z _ a- W vJ = CD CD N 06 LU in Q > >CO L � � LU LU g ~ � z m z Q CO -0 z uj C7 p C� C!) z = mO Q w Q w O w C6= � p p U p U E= Cn 0 Z V J W0 Ow Z (D W N< J ry W Z rW V SHEET G-002 S GENERAL SEWER NOTES Q4) ALL CONSTRUCTION OUTSIDE RIGHTS-OF-WAY SHALL TAKE PLACE WITHIN THE PERMANENT AND TEMPORARY ACCESS EASEMENTS SHOWN. 22. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING ROADS DURING CONSTRUCTION = AND SHALL REPAIR ROADS PER REQUIREMENTS OF THE NORTH CAROLINA DEPARTMENT OF 2. CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS TO EQUAL OR BETTER CONDITION THAN THE TRANSPORTATION. NO OPEN CUTS OF EXISTING ROADS SHALL BE ALLOWED EXCEPT WHERE INDICATED ON ORIGINAL SITE, OR AS NOTED. THE DRAWINGS OR WHERE SPECIFIC PERMISSION IS GRANTED BY THE NORTH CAROLINA DEPARTMENT OF 3. LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE ONLY. EXACT LOCATIONS ARE TO BE TRANSPORTATION. SAND OR A SIMILAR MATERIAL APPROVED BY THE NORTH CAROLINA DEPARTMENT OF VERIFIED IN THE FIELD BY THE CONTRACTOR. AT LEAST THREE DAYS PRIOR TO CONSTRUCTION, TRANSPORTATION SHALL BE PLACED ON THE ROAD TO AID IN THE CLEAN UP AFTER CONSTRUCTION. A CONTRACTOR MUST NOTIFY EXISTING UTILITY OWNERS. CALL 811 BEFORE YOU DIG. MINIMUM OF 2" OF SAND SHALL BE PLACED ON THE ROAD PRIOR TO STOCKPILING SPOIL MATERIAL ON THE ROAD SURFACE TO FACILITATE CLEANUP. 4. ALL WORK NEAR AND AROUND WATERWAYS MUST CONFORM TO THE RULES OF THE STATE OF NORTH NN CAROLINA. 23. CONTRACTOR SHALL MAINTAIN SEWAGE FLOW IN SEWER SYSTEM AT ALL TIMES AND SHALL PROVIDE 5. CONTRACTOR MUST PROVIDE EROSION CONTROL DEVICES TO CONTROL RUNOFF FROM THE BYPASS PUMPING AND/OR PIPING AS REQUIRED. NO SANITARY SEWER OVERFLOWS ARE PERMITTED. CONSTRUCTION SITE. CONTRACTOR WILL BE RESPONSIBLE FOR ANY FINES THAT MAY BE LEVIED DUE ~ W TO POLLUTION CREATED DURING CONSTRUCTION. 24. SPECIFICATIONS AND REQUIREMENTS BY MSD SUPERSEDE ALL OTHERS IN THE INSTALLATION OF THE PROPOSED EXTENSION. 6. CONTRACTOR SHALL FOLLOW ALL FEDERAL, STATE AND LOCAL HEALTH AND SAFETY REGULATIONS PERTAINING TO CONSTRUCTION OPERATIONS. 7. SEWER FORCE MAINS AND WATER LINES SHALL HAVE 3'-0" MINIMUM COVER UNLESS OTHERWISE SHOWN ON THE DRAWINGS. 8. WATER AND SEWER LINES SHALL HAVE A MINIMUM 10' HORIZONTAL SEPARATION OR A MINIMUM 18" VERTICAL SEPARATION WITH THE WATER OVER SEWER, OR BOTH WATER AND SEWER LINES SHALL BE DUCTILE IRON PIPE 10' EITHER SIDE OF THE CROSSING. 9. SEWER AND STORM SEWER LINES SHALL HAVE A MINIMUM 18" SEPARATION. IF 18" SEPARATION IS NOT OBTAINABLE, DUCTILE IRON PIPE SHALL BE USED FOR THE SEWER LINE OR A SUPPORTING MATERIAL SUCH AS FLOWABLE FILL SHALL BE INSTALLED BETWEEN THE PIPES. 10. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION. 11. UNLESS OTHERWISE NOTED, ALL BURIED PIPE SHALL BE INSTALLED WITH PUSH -ON JOINTS AND EXPOSED PIPING SHALL BE FLANGED JOINT. 12. LEGAL DESCRIPTIONS FOR PROPOSED EASEMENTS BY OTHERS. 13. SITE TOPOGRAPHIC AND BOUNDARY SURVEY PROVIDED BY SURVEYOR NOTED ON PLANS. 14. CONTRACTOR SHALL NOTIFY THE PROPER LOCAL AUTHORITIES 24 HOURS PRIOR TO ANY ROAD BEING CLOSED FOR CONSTRUCTION, INCLUDING BUT NOT LIMITED TO LOCAL NEWSPAPER, RADIO STATION, FIRE DEPARTMENT, COUNTY SHERIFF'S DEPARTMENT, AMBULANCE, AND COUNTY EMERGENCY AGENCY. ALL TRAFFIC CONTROL SHALL CONFORM TO THE REQUIREMENTS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION. 15. CONTRACTOR SHALL NOTIFY THE ENGINEER AFTER EXISTING BURIED UTILITIES HAVE BEEN LOCATED AND 24 HOURS PRIOR TO CONSTRUCTION. 16. LOCATIONS SHOWN FOR SANITARY SEWER SERVICES ARE ASSUMED. COORDINATE LOCATIONS OF ALL PROPOSED SEWER SERVICE CONNECTIONS WITH PROPERTY OWNER PRIOR TO CONSTRUCTION. 17. CONTRACTOR SHALL FIELD VERIFY ALL PROPOSED MANHOLE TOP ELEVATIONS AND EXISTING MANHOLE INVERTS PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. CONTRACTOR SHALL ADJUST ALL PROPOSED SEWER STRUCTURES TO MATCH FINISHED PAVEMENT ELEVATIONS. COSTS OF RAISING STRUCTURES SHALL BE CONSIDERED INCIDENTAL TO OTHER WORK ON THE PROJECT. 18. MANHOLES AND CASTINGS SHALL MEET THE REQUIREMENTS OF OWNER AS WELL AS THE PROJECT SPECIFICATIONS. 19. 4" SANITARY SEWER SERVICE LINES SHALL BE INSTALLED AT 2.0% MINIMUM SLOPE AND SHALL BE DUCTILE IRON IN PAVED AREAS. 20. ALL FENCE DAMAGED DURING CONSTRUCTION SHALL BE REPLACED WITH LIKE MATERIALS IN A WORKMANLIKE MANNER AND IN ACCORDANCE WITH STANDARD FENCE CONSTRUCTION PRACTICES AT THE CONTRACTOR'S EXPENSE. 21. CONTRACTOR SHALL FIELD LOCATE ALL BURIED TELEPHONE LINE IN CONFLICT WITH THE PROPOSED UTILITY LINE. WHERE NECESSARY, EXISTING BURIED TELEPHONE LINE SHALL BE TEMPORARILY MOVED DURING CONSTRUCTION OF THE PROPOSED UTILITY LINE AND RE-LAID AT NO ADDITIONAL COST TO THE OWNER. 25. INSTALLATION OF PROPOSED SEWER EXTENSION AND ALL PUBLIC SANITARY SEWER WORK ASSOCIATED WITH PROJECT TO BE PERFORMED BY NORTH CAROLINA LICENSED UTILITY CONTRACTOR. 26. CONTRACTOR SHALL PROVIDE CCSD FIELD DENSITY REPORTS VERIFYING SEWER BUILT IN FILL AREAS ARE COMPACTED TO 95% STANDARD PROCTOR. 27. PERMANENT PUBLIC EASEMENT TO BE CLEARED AND REMAIN CLEAR OF ANY TREES AND/OR PERMANENT 28. STRUCTURES. A LANDSCAPE PLAN IS NOT INCLUDED IN THE SCOPE OF THIS PROJECT. SPECIFICATIONS AND REQUIREMENTS OF THE METROPOLITAN SEWERAGE DISTRICT SUPERSEDE ALL OTHERS IN THE INSTALLATION OF THE PROPOSED EXTENSION. 29. THE INSTILLATION OF THE PROPOSED SEWER EXTENSION AND ALL PUBLIC SANITARY SEWER WORK ASSOCIATED WITH THIS PROJECT TO BE PERFORMED BY NC LICENSED UTILITY CONTRACTOR. 30. PROJECT SITE IS LOCATED OUTSIDE OF 100 -YR FLOODPLAIN. 1. WATER CONSTRUCTION ON THIS SITE IS AUTHORIZED BY PERMITS ISSUED BY THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY (NCDEQ) AND AUTHORIZED BY THE CITY OF HENDERSONVILLE. THE WORK IS SUBJECT TO INSPECTIONS AT ALL TIMES BY REPRESENTATIVES OF NCDEQ, THE CITY OF HENDERSONVILLE, THE OWNER OR THE ENGINEER. THE PERMITS REQUIRE CERTIFICATION OF COMPLETION OF THE WATER SYSTEMS BY THE ENGINEER AND THE APPLICANT PRIOR TO ISSUANCE OF FINAL OPERATION APPROVAL. 2. MATERIALS AND INSTALLATION FOR WATER CONSTRUCTION SHALL CONFORM TO THE LATEST VERSIONS OF CITY SPECIFICATION AND DETAILS AND AWWA STANDARDS AND REQUIREMENTS. 3. CONTRACTOR SHALL NOTIFY NC811 & APPROPRIATE UTILITIES AGENCIES PRIOR TO PERFORMING ANY WORK. 4. REGULAR WORKING HOURS SHALL BE FROM 7:00 AM TO 5:00 PM MONDAY THROUGH FRIDAY, EXCEPT IN CASES OF EMERGENCY OR OTHERWISE APPROVED IN WRITING BY THE CITY OR AUTHORIZED REPRESENTATIVES. THE CONTRACTOR SHALL ENSURE THE CONSTRUCTION SITE IS SAFE FOR ANY PERSONS WHO MAY BE ON SITE DURING NON -WORKING HOURS. 5. ALL PERSONS SHALL BE COURTEOUS AND RESPECTFUL TO THE PUBLIC. CURSING OUR FOUL LANGUAGE IS NOT PERMITTED AND WILL NOT BE TOLERATED. 6. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING TRAFFIC CONTROL ON ALL ROADWAYS DURING THE PROJECT. THE CONTRACTOR SHALL NOTIFY LOCAL EMERGENCY, SCHOOL AND OTHER NECESSARY AUTHORITIES PRIOR TO ANY STREET CLOSING OR TRAFFIC CHANGE. 7. THE CONTRACTOR AT HIS OWN EXPENSE SHALL KEEP THE CONSTRUCTION SITE AND ADJACENT PUBLIC AND PRIVATE ROADWAYS CLEAN DURING THE PROJECT. THE CONTRACTOR IS ALSO RESPONSIBLE FOR CONTROLLING DUST WITHIN THE PROJECT AREA. 8. THE CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION IN ACCORDANCE WITH THE LINES, GRADES AND ELEVATIONS SHOWN ON THE PLANS OR AS GIVEN BY THE ENGINEER IN THE FIELD. 9. CONTRACTOR SHALL VERIFY THE EXACT LOCATION AND THE ELEVATION FOR ALL UTILITIES, DRAINAGE AND OTHER UNDERGROUND FACILITIES BOTH EXISTING AND PROPOSED, AND SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO CONSTRUCTION. 10. CONTRACTOR SHALL PROTECT EXISTING UTILITIES DURING CONSTRUCTION. REPAIRS SHALL BE MADE IN ACCORDANCE WITH APPLICABLE STANDARDS OF APPROPRIATE AGENCIES AT THE CONTRACTOR'S EXPENSE. 11. DURING CONSTRUCTION THE CONTRACTOR SHALL MAINTAIN THE OPERATION OF EXISTING UTILITIES WITH THE LEAST AMOUNT OF SERVICE INTERRUPTION POSSIBLE IN COORDINATION WITH THE CITY OF HENDERSONVILLE. CONTINUOUS SERVICE, PUBLIC HEALTH AND SAFETY CONSIDERATIONS SHALL EXCEED ALL OTHERS AND CONTRACTOR'S SCHEDULE, PLANS AND WORK SHALL AT ALL TIMES BE SUBJECT TO ALTERATION AND REVISION IF NECESSARY FOR THESE CONSIDERATIONS. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE TEMPORARY OR PERMANENT RELOCATION OF STRUCTURES AND UTILITIES, INCLUDING BUT NOT LIMITED TO POLES, SIGNS, FENCES, HYDRANTS, VALVES, PIPING, CONDUITS AND DRAINS THAT INTERFERE WITH THE POSITIONING OF THE WORK AS SHOWN ON THE DRAWINGS. 13. CONTRACTOR SHALL BE REQUIRED TO CONFORM AND COMPLY WITH ALL RESTRICTIONS AND EASEMENT CONDITIONS AND IS RESPONSIBLE FOR ALL RELATED INCIDENTAL COSTS INVOLVED. 14. EXISTING WATER SERVICES SHALL BE REPLACED TO THE EXISTING METER UNLESS OTHERWISE APPROVED IN WRITING BY THE CITY. SPLICING OF THE WATER SERVICE ON THE DOWNSTREAM SIDE OF THE METER IS NOT PERMITTED. 15. ALL DISTURBED AREAS, INCLUDING BUT NOT LIMITED TO ASPHALT, CONCRETE, DRIVEWAYS, ROADS, LANDSCAPING, SHALL BE REPAIRED TO EQUAL OR BETTER CONDITION THAN THE ORIGINAL SITE. GRASS AND LANDSCAPED AREAS FILL MATERIAL MUST BE REPLACED IN TRENCH TO GRADE AS SOON AS WATERLINE CONSTRUCTION ALLOWS. ADEQUATE SEEDING AND STRAW OR MULCH SHALL THEN BE APPLIED TO THE DISTURBED TRENCH AREA. ADDITIONAL FILL AND SITE RESTORATION MAY BE REQUIRED WITHIN THE WARRANTY PERIOD AT THE CITY'S DISCRETION. 16. CONTRACTOR SHALL PROVIDE EROSION CONTROL DEVICES TO CONTROL RUNOFF AS REQUIRED. THE CONTRACTOR IS RESPONSIBLE FOR ANY FINES THAT MAY BE LEVIED DUE TO RUNOFF FROM CONSTRUCTION. 17. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FOLLOW ALL APPLICABLE FEDERAL, STATE AND LOCAL HEALTH AND SAFETY REGULATIONS PERTAINING TO CONSTRUCTION OPERATIONS. 18. ALL WATER MAINS SHALL HAVE 3 FEET MINIMUM COVER. 19. INSTALL FERROUS PIPING FOR BOTH WATER AND SEWER WITHIN 10 FT. OF A CROSSING IF: 19.1. SEWER LINE CROSSES OVER WATER, QH 19.2. VERTICAL CLEARANCE BETWEEN WATER AND SEWER IS LESS THAN 18 INCHES. 19.3. MAINTAIN 10 FEET HORIZONTAL SEPARATION BETWEEN SEWER AND WATER MAINS UNLESS LAID IN SEPARATE TRENCHES WITH THE BOTTOM OF THE WATER LINE AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER LINE OR USE FERROUS MATERIAL FOR BOTH WATER AND SEWER. 20. MAINTAIN 18 INCHES VERTICAL SEPARATION BETWEEN STORM DRAIN AND WATER, OR INSTALL FERROUS MATERIAL WATER LINE WITHIN 10 FEET EACH SIDE OF CROSSING. 21. TAPS GREATER THAN ONE -INCH IN DIAMETER IN EXISTING, ACTIVE WATER MAIN ARE TO BE PERFORMED BY THE CITY UNLESS OTHERWISE APPROVED IN WRITING BY THE CITY. TAPS IN NEW CONSTRUCTION ARE TO BE PERFORMED BY THE CONTRACTOR IN ACCORDANCE WITH CITY REQUIREMENTS. 22. ALL WATER METERS WILL BE SET BY CITY STAFF UNLESS THE CONTRACTOR IS GRANTED WRITTEN PERMISSION BY THE CITY. 22.1. THE CONTRACTOR WILL PROVIDE THE CITY NOTICE OF 10 WORKING DAYS MINIMUM PRIOR TO THE DATE OF METER INSTALLATION. 22.2. THE CONTRACTOR WILL PROVIDE A LICENSED PLUMBER DURING THE METER INSTALLATION TO VERIFY LINE SERVICES IN ALL MULTI -METER BOXES. 23. ALL PUBLIC WATER MAIN CONSTRUCTION SHALL BE PERFORMED BY A NORTH CAROLINA LICENSED UTILITY CONTRACTOR. 24. ALL WATER APPURTENANCES ARE TO BE MADE USING LEAD FREE MATERIALS. PIPE, FITTINGS, VALVES, HYDRANTS, PIPE CLAMPS, RESTRAINTS, FLANGES, CASTINGS, REBAR, HATCHES, INLETS, METER BOXES AND ALL OTHER CAST IRON COMPONENTS SHALL BE MANUFACTURED IN THE USA. 25. RESTRAINED JOINTS BY AN APPROVED PIPE MANUFACTURER ARE TO BE USED FOR ALL PUBLIC WATER LINES WHERE THRUST RESTRAINING IS REQUIRED IN ACCORDANCE WITH THE PLANS AND MANUFACTURER'S SPECIFICATION. CONCRETE THRUST BLOCKS ARE PERMITTED ONLY WHERE CONNECTIONS ARE MADE TO EXISTING WATER LINES OR WHERE THE USE OF MECHANICAL RESTRAINT IS NOT FEASIBLE. 26. ALL FIRE HYDRANTS, VAULTS, BACKFLOW PREVENTERS, HOT BOXES AND WATER METERS ARE TO BE INSTALLED ON RELATIVELY FLAT AREAS OUTSIDE OF PAVEMENT. 27. TAMPERING WITH OR ILLEGAL USE OF THE PUBLIC WATER SUPPLY WILL RESULT IN SUSPENSION OF WATER SERVICE, INCLUDING DOMESTIC AND COMMERCIAL, UNTIL FINAL APPROVAL BY THE CITY IS ISSUED. A PERSON FOUND TO BE USING WATER ILLEGALLY SHALL BE SUBJECT TO PENALTIES OR FINES, AS PRESCRIBED AND APPROVED BY CITY COUNCIL. TESTING & INSPECTION: 1. NOTIFY THE CITY OF HENDERSONVILLE AND ENGINEER AT LEAST 5 WORKING DAYS BEFORE STARTING CONSTRUCTION OF WATER FACILITIES TO SCHEDULE A PRE -CONSTRUCTION CONFERENCE. THE ENGINEER SHALL PERIODICALLY INSPECT THE PROGRESS OF INSTALLATION AT A MINIMUM AND SHALL COMPLETE A FINAL WATER CERTIFICATION. 2. ALL CHANGES TO THE APPROVED CONSTRUCTION PLANS AND SUBMITTALS MUST BE APPROVED IN WRITING BY THE CITY PRIOR TO IMPLEMENTATION IN THE FIELD. 3. THE CONTRACTOR SHALL FURNISH SECURE AND PROVIDE ALL NECESSARY TESTING MATERIALS, EQUIPMENT, LABOR. THE CONTRACTOR SHALL COORDINATE TESTING, FLUSHING, DISINFECTION, AND BACTERIOLOGICAL SAMPLING WITH CITY INSPECTOR. 4. THE ENGINEER OR CONTRACTOR SHALL NOTIFY THE CITY CONSTRUCTION INSPECTORS 72 HOURS (MINIMUM) PRIOR TO ANY WATER MAIN OR TESTING OPERATIONS. AT A MINIMUM CITY STAFF SHALL BE NOTIFIED PRIOR TO TAPS, TESTING, FLUSHING, DISINFECTION, AND SAMPLING. 5. PRESSURE TEST WATER MAINS TO 200 PSI MIN. FOR A MINIMUM OF TWO HOURS IN ACCORDANCE WITH CITY REQUIREMENTS AND AWWA C600. 6. DISINFECT WATER LINES AND PROVIDE ACCEPTABLE BACTERIOLOGICAL TEST FROM A CERTIFIED TESTING LABORATORY IN ACCORDANCE WITH CITY REQUIREMENTS AND AWWA C651. THE CONTRACTOR MAY ELECT TO USE THE CITY'S CERTIFIED TESTING LABORATORY. 7. PRIVATELY OWNED FIRE SYSTEMS SHALL BE APPROVED BY THE APPROPRIATE LOCAL PERMITTING AUTHORITY. THE CITY ENGINEERING OR WATER AND SEWER DEPARTMENTS ARE NOT RESPONSIBLE FOR ENSURING COMPLIANCE WITH APPROPRIATE FIRE PROTECTION REGULATIONS. THE CITY DOES NOT PROVIDE ANY GUARANTEE OF ITS WATER SYSTEM'S CAPABILITY TO DELIVER WATER FLOW AND RESIDUAL PRESSURE THE FIRE PERMITTING AUTHORITY MAY REQUIRE. 8. ALL BACKFLOW PREVENTION ASSEMBLIES SHALL BE USC APPROVED AND REVIEWED BY THE CITY'S. PROTECTION OF THE PUBLIC WATER DISTRIBUTION SYSTEM SHALL BE ASSURED BY INSPECTION OF THE INSTALLATION AND TESTING OF BACKFLOW PREVENTION DEVICES IN ACCORDANCE WITH APPROPRIATE LOCAL, STATE, AND FEDERAL REGULATIONS. 9. CONSTRUCTION WATER SOURCING MUST BE APPROVED IN WRITING BY THE CITY. CONSTRUCTION WATER CONNECTIONS SHALL BE PAIRED WITH AN IRRIGATION METER AND APPROVED BACKFLOW PREVENTION ASSEMBLY. THIS ASSEMBLY INSTALLATION MUST BE TESTED BY A LICENSED PLUMBER AND TEST RESULTS SUBMITTED TO THE CITY BEFORE USE OF CONSTRUCTION WATER. 10. SECURE FINAL WRITTEN ACCEPTANCE FROM THE CITY OF HENDERSONVILLE PRIOR TO ACTIVATION OF THE SYSTEM. WATER SERVICE WILL NOT BE PROVIDED UNTIL WRITTEN ACCEPTANCE OF THE SYSTEM IS ISSUED BY THE CITY. 11. THE ENGINEER SHALL SUPPLY THE CITY WITH FINAL AS -BUILT DRAWINGS AND COMPLETE ALL PROJECT CLOSE OUT REQUIREMENTS. THE STANDARD WATER DETAILS ARE FOR THE SOLE USE OF PROJECTS DIRECTLY FOR, OR THOSE PROJECTS IN WHICH OWNERSHIP WILL BE TRANSFERRED TO THE CITY OF HENDERSONVILLE. THESE TYPICALS ARE INTENDED TO SHOW THE CITY OF HENDERSONVILLE'S EXPECTATIONS FOR THE GENERAL LAYOUT, ARRANGEMENT, AND THE QUALITY OF EQUIPMENT AND MATERIALS FOR WATER DISTRIBUTION SYSTEM ITEMS AND THEIR RELATED APPURTENANCES. IT REMAINS THE SOLE RESPONSIBILITY OF THE ENGINEER IN RESPONSIBLE CHARGE (ERC) OF EACH APPLICATION TO DETERMINE, DESIGN TO, AND CERTIFY TO THE DESIGN PARAMETERS FOR EACH INSTALLATION. THE ERC MUST ALSO ENSURE THE DESIGN COMPLIES WITH THE MINIMUM DESIGN CRITERIA OF NC DIVISION OF ENVIRONMENTAL QUALITY AND ALL LOCAL AND STATE LAWS AND REGULATIONS. DATE: 03/14/2019 WD DWG. NO. 1 ISCALE: NOT TO SCALE I City of Hendersonville Engineering Department 305 Williams Street Hendersonville, NC 28792 (828) 697-3000 (office) www.cityofhendersonville.org WATER DETAILS GENERAL NOTES NO. I DATE I BY REVISION DESCRIPTION Z J NO I..L U /1 W O Z ROM J D z D O 0 z O N) w LL] 0 z LL] L N U) Lo W_ o W SLI U IY ' cn zo7 z W o 0 J_ (� U LL -0_ SHEET G-004 = M 0) < CD W o8 NN m ~ W Z =) � Iz 0 1 z m z z w M w Q w Q � 0 0 U 0 /1 W O Z ROM J D z D O 0 z O N) w LL] 0 z LL] L N U) Lo W_ o W SLI U IY ' cn zo7 z W o 0 J_ (� U LL -0_ SHEET G-004 �I �I ZONING BOUNDARY LINE 'I I 3 I 0 GRAPHIC SCALE PLAN 40 80 160 240 I INCH = 80 FEET 'I I I \/0000 ODOM, MARSHA A SANITARY SEWER MANHOLE I I \ PIN: 9650079059 TOP EL: 2086.45 1/2" OTIPF I DB: 1032 PG: 81 I EXISTING GRAVEL DRIVE TO \ BUSH, RONALD E; BUSH, JOYCE R \ I I REMAIN (TYP.) SINCLAIR, FROSTY A; FROSTY A SINCLAIR \ BENNETT, LARRY; THE LARRY AUSTIN, BRUCE; AUSTIN, THERESA \ PIN: 9650174702 ADAMS, BRYAN; ADAMS, F—N DB:534 PG:389 REVOCABLE TRUST \ BENNETT LIVING TRUST PIN: 9650173407 STEFANIEPIN: 9650068876 PIN: 9650171258 DB: 1586 PG: 673 PIN: 9650176986 EXISTING 50' WIDE DB:1431 PG:204 DB: 3259 PG:154 DB: 1616 PG: 518 ^---��ON LINE I EXISTING 50' WIDE \ / A HIGH PRESSURE I �' I �" GAS EASEMENT \ \ I HIGH PRESSURE I GAS EASEMENT DIT' OTIPF _--___- _ 1/ " RBF / OW @/i TRBF 1/2" OTIPF 1}2/�'�OTIPF EXISTING WATER LINE I I BLUE pAJ __ -- --- 368.30' 1 361.91' 15.75' .60' — T _ UM 9 - 6 21 -- — I.E.: 2 89 1 _ — — - -- ------ — — 396.76 2 — - — - _ - — — - — — — —— , cn „ — 29 — — — —---------� -- _i=- U-- U--� U—_S�§39t�U----r P S36 �I W ---� -- ---> --- ---- S36 3fi2�"k1C----- S37°15'29"W S3 56 \ J — — — _ - _ /� ' i' �-- �' y � 25 54 _ -/--------- _�+ ----- „W 135'31'35"W-- t�+' \ - - ) 1 / - - - _ FBF /i Ft EXISTING 15" RCP TO I. 1. 4' ' __ / -2105-I I \ \ \\\\`� �� LOT _ \==____� = -- --_ �_ \ / := ^ NDSCAPI OTIPF o \ \ \ RASMUSSEN, PHILIP M; \ / / / 2,25_— -- ' REMAIN (TYP.) I RA A r \ \ ------ ' ' - / / I LE.:, 2' --- 'F` I —x — � SMUSSEN, PRISCILLA _ 3 _ \------------------ - 1 �_� - _ /. I� �---7 - - - ----------------------------------LOT 1/�-/--1----� --�� PIN: 9650161982 I �,� _ \� ` ` --- �j%% �''�//i'% 212° �, : ^\\ /'' \\ /% ' 00o, �' � / D6:1370 PG: 471 �, _ =/ // \ �� 0 I I I / ���, SPANO & ASSOCIATES / I m`� �'� `�� LOT 3 IZ II,:> HAYWOOD, LLC -- / Z - /�s_ N w v 01 PIN: 9650069662 / 212 \, SPANO &ASSOCIATES / ——= — HAYWOOD LLC-- `DB:3278 PG:574 / Z — ---- / ----- — --- PIN: 9650175207 __---___--- 2120-7— o�_ DB: 3278_ PG: 574 _ —2115— ♦ SANITARY SEWER MANHOLE I I I I Iz: 1 I ` I \, I. < / m - - - - - - - _ _ _ - _ _ - - - _ ♦ �iI / -'/ \ TOP EL: 2084.72' c� i \ I \ \ I / 2115- A,- 12" PVC IN (SE) I.E.: 2077.53' sI \ EXISTING PROPERTY LINE,12" PVC OUT (NW) I.E.: 2077.49' ?y\\\� \ \ \ \ � \ 1---------- /\ TROUT WATERSNEAR CENTERLINE OF \ �' -' BUFFER (TYP.) EXISTING 16' \�_ \ I =R_ _---_ .-I I A I \\\\ f 1/2" RRFZi - ,�\ii�WIDE ROADWAY 1 �� "� EXISTING 16 WIDE ROADWAY \ _ =2,1D= �— - '\___ \021- - - --M021- - - - -M021-M\ \ \ / /it ASPHALT - / TO R MAIN BLUE °\ DRm 'Zoos' �r�_---------��° ==rI GAgSTUe \� '' �\II/////��fLE\2,oLs4 --- -- �' --1 /�///r/ I I^ f —�iG 30 PERENNIAL ♦ I o_ /Ac I I t = _ _ -, _ ___ . s ____L °T_ STREAM BUFFER CONSERVING CAROLINA ♦ I I I �, \ _ _ /— ����� / \ —�— \" a PIN: 9650059838 ♦ F I I I 1 \` \ \I ) LOT 6 - - _ 1 l cll I �� ' _— — °S ��i// — �y�\ (TYP.) ♦ I I SPANO & ASSOCIATES., DB: 28 PG: 552 � r� � I I ) — � ' i 1 TOP 18" CPP , -2105 rn d i \ I I I HAYWOOD, LLC -, /i /) Y/10 I INI� I \ \ '°° l I 1 PIN: 9650161443 ��� �_ s"ti�� / / : '<�'�_-z 1 Top FI �� a 65' ///// / - i I I \ \ \ \ \ EXISTING CPP- TO �!� =--- �— \ / EXISTING STREAM CENTERLINE — _ L \ DB: 3278 PG: 574 _ EL: 2,,.s3' /� —� = \\ $� SANITARY SEWER MANHOLE I I \ \\ ` \ I I ( ) °— - ''� \'1 05 OF UNNAMED TRIBUTARY TO k*YD \ _� \ \ ✓�/Ir — REMAIN TYP. /, -- ,�, / /,�/ `� —� \\rr.\\\l �N��' �� TOP EL: 2088.81' F \ \ \ J// - J- / i / \\ \\ \ \ / ��' 12" PVC IN SE I.E.: 2078.14') s I I I __- - ��\ \ \ _ %� J - - - �, ;W /i j'1 :i / / / %� / / / �' tR ' /\ + i O 1 \\ — _ .— ___ _ / — ,� MILLS CREEK (FLOWING WEST) 12" PVC OUT (NW) I.E.: 2077.93' ti / O I I /-_ - x,`\�� = - '�µ�i� - - - - / v _' i I it - ^ \ J// /�(f 11 i i /' ' ,''i - - / // f ✓ i / OOD 1 (� I I I' f % \ - I I.E. HAYVV NOL DRIVc I p r/�i ' ' - _ � N _�i �'� /SANITARY SEWER MANHOLE K RE)W1= /SR -2044 IIII TOP EL: 2118.74' SANITARY SEWER MANHOLE TOP EL: 2089.66''° I ' i - / / RDFUE P 12" PVC IN 8.72' Q 12" PVC OUT (NW) I.E.: 2078.72' I o �70.96' OUCRETEv//I % EXISTING LOT INTERIOR PR OPERTY LINE EXISTING � - LOT4 TO BE SUBDIVIDED (TYP.)P.) X _=RIGHT—OF—WAY (TYQ SPANO & ASSOCIATES / H AYWOOD, LLC EXISTING 15" CPP TO BE /I I I r �/PIN: IN: I 96/50165805 I D:3278 PG:574 ,j i EXISTING DELINEATED LINEAR WETLAND (TYP.)REMOVED -+/, / , EL: 2091.3 1 / / I I I/— —' / III I I /// / (/ \ i-ROJF EL: 2091.49' INV. 2086.16 III I ( / INV EL: 2086.33' / / / I / / / / / O� _ - - - - - -- DRIVE \ EXISTING ASPHALT I . � �/It� =' / �,/ ,—III I Wl ,/ /� ,`�11 /— �_--- i i IJ/r��; �.o%'� ' ° DRIVE TO BE II'�r - I / / \\ , / / / I I 5\ DEMOLISHED I 'I LOT 7 -� ► �� ,� LOT 5 I SPANO & ASSOCIATES 1I �, � I SPANO & ASSOCIATES �� / I / / 4ss P SANITARY SEWER MANHOLE I I I HAYWOOD, LLC ,/ / / (7; \ HAYWOOD, LLC TOP EL: 2087.59' / 12" PVC IN (SE) I.E.: 2079.34' ss I PIN: 9650163229_/ PIN: 9650164528 DB:3278 PG:574 --�� 12" PVC OUT (NW) I.E.: 2079.16' I I �\ — I / s�RBF y I , v / \ DB: 3278 PG: 574 � SANITARY 093.61' TOPEL2 19W9R MANHOL CONSERVING CAROLINA I I 's•. / r — — / // / \ \ I/ / ^' / / PIN: 9650059838 1 1 18 48"E / / / / I I I I I I tih lr POST FOUND DB: 28 PG: 552I I III \ 34 6 ��— ' / // /�/1� <n o I I.E.: 203\' POST FOUND EXISTING PROPERTY LINE (TYP.) EXISTING 100' I RIGHT—OF—WAY (TYP.) o o / / 1 I I LOT 8 / / / / POST FOUND 0 SPANO & ASSOCIATES k i // ^'. HENDERSON CO. BOARD OF PUBLIC I.E.: 2093146'-'-I I HAYWOOD, LLC ON LVE syy SCHOOLS PIN: 9650164056 �� ��° PIN: 9650262638 I I o/ RBF TOP EL: 2110.75 MANHOLE DB: 824 PG: 213 EXISTING SANITARY I I I � ! DB: 3278 PG: 574 ' SEWER LOCATION I.E.: 209t.18a, ,',' n r / \ i / — — - T- T / � . FOUN lI 1 I I // 2� / ^w I I 5, '; �IF //=\/� ( I I I I ► / ���� j �24" CMP EXISTING 15 CPP CMN LINE 2224 TO REMAIN (TYP.) pBFr I.E.: 2109.39' I I I M`Ip /R POST FOVrt UND , 1 i o SANITARY SEWER MANHOLN POST FOUNt� TOP EL: 2088.70'--------(s g I o N-- s2,y II \ 011�1 I 1/2" RBF I 1P AP r I I ;N\ 7'49'49"� SANITARY SEWER MANHOLE W - - - - - W - - - - - W 3 1° TOP EL: 2108.95' —_M 41 EXISTING DELINEATED WETLAND (TYP.) _ T I I M M_ - i I I — I I I I I 3 I I NOTE: 1. THE 30' PERENNIAL STREAM & 25' TROUT WATERS BUFFER WIDTHS SHOWN ARE MEASURED HORIZONTALLY FROM THE TOP OF STREAM BANK. REVISION DESCRIPTION � W011 � W J U 0 w 0 U 2 V) d w W >0 Q U 00 W N } U) � rx w �= 06 O M--4 U) o U) H N U) Q N 0U c Uo (/) 0 U m U) x 0 � a 006 Wo U) r� z o °O N v 1 Z C) �Z LLJ v1�a U) = Q w O J 00 O -3 0 0 0 w U LL — U W¢ W� W � o W� 3: U � W J O w 0 J 2 z 0< � J Z Z 0 01-- 0 1U J (D0 Z 2i Lu U) Q X oes W SHEET U Q z Z J O J J 2 V) d 0. >0 Q U 00 W N } U) Q W �= 06 O Z U) > � U) H [-.- U) Q Z 0U c Uo (/) 0 U m U) Z OQ z O 006 U) �0w z o Z C) �Z LLJ G U) = z 0< � J Z Z 0 01-- 0 1U J (D0 Z 2i Lu U) Q X oes W SHEET 2 x W M Q W CD N } = W O a, 06 w Z m 0 > � > � U � c p z m z� Q� .o z w 2 CD 0 z o G Q w Q w O J 00 O -3 0 0 0 0 U LL — U z 0< � J Z Z 0 01-- 0 1U J (D0 Z 2i Lu U) Q X oes W SHEET ZONING BOUNDARY LINE ' PLAN 80 0 40 80 GRAPHIC SCALE 160 240 1 INCH = 80 FEET 00 ODOM, MARSHA A PIN: 9650079059 \ DB: 1032 PG: 81 I I \ BUSH, RONALD E; BUSH, JOYCE R SINCLAIR, FROSTY A; FROSTY A SINCLAIR BENNETT, LARRY; THE LARRY AUSTIN, BRUCE; AUSTIN, THERESA \ PIN: 9650174702 ADAMS, BRYAN; ADAMS, I PROPOSED LARGE, DECIDUOUS REVOCABLE TRUST BENNETT LIVING TRUST PIN: 9650173407 DB. 534 PG. 389 \ STEFANIE PIN: 9650068876 PIN: 9650171258 DB: 1586 PG: 673 PIN: 9650176986 / I I TREE, 24 STREET TREES DB: 1431 PG: 204 DB: ��sa �d DB: 1616 PG: 518 PROPOSED B2 BUFFER I REQUIRED ALONG EXISTING EXISTNOT IINCLUDEDNG LOT ISN ' \ \ ' HAYWOOD PARK DR. I EXISTING 50 WIDE I \ THIS P OJECT HIGH PRESSURE INSIDE 50' SETBACK I I SEE PLANTING SCHEDULEZ GAS EASEMENT ------ ------------------------------ ------------- -- --_---- _ LOT 2 GRAVEL DRI I I I I I RASMUSSEN, PHILIP M; I \ \ f I I \ \ \------------------------- I RASMUSSEN, PRISCILLA A-I--------------------------�----------------------------------------- N --- --- ---- - I------------I---I----------------r---------------7- PIN: 9650161982 I I \ \ �= \ \ \ 1.11 AC N I 1 \ 2() 48187.2 SF I� I I I III I DB: 1370 PG: 471 I \ \ \ C9 I I 0.69 AC I I I \ \ � 0.95 AC \ \ FFE: 2118 Z 29969.7, SF _ I I 1 I \ \ \ (�) 41503.1 SF IZ I FFE: 2109 I I r --- AC I 1 0.59 AC FFE: 2121 \ \ \ /� IN I I I I 25824.7 SF I I 25809.0 11 I APPROXIMATE 1 �% \ \ \ - N I 1 I I 'FFE• 2111 I 1 i FFE: 2111 1 , 50' SETBACK FROM ROW LINE TYP. EXISTING 16' I WIDE ROADWAY I 20)yI c � TO R MAIN II CONSERVING CAROLINA ` I PIN: 9650059838 o DB:28 PG:552 EXISTING 10' X 70' I SITE TRIANGLE (TYP.) - - HAYWOOD KNOLLS �o►a� DR/VE I EXISTING 60' /I' RIGHT-OF-WAY NI I (TYP.) I i PROPOSED B2 BUFFER 0 0 INSIDE 50' SETBACK I I I 50' SETBACK FROM I ROW LINE (TYP.) o I I CONSERVING CAROLINA PIN: 9650059838 I DB:28 PG:552 I M 0 I EXISTING 100 I RIGHT-OF-WAY I (TYP.) I A co I I PROPOSED 10'X70' I i SITE TRIANGLE (TYP.)cn I i I i o I � I � PROPOSED B2 BUFFER I i INSIDE 50' SETBACK I I i 36' i I I 1 I I EXISTING 45 1I II 1III ii .AC 03 1 I I 1 2 43.0 SF \ \ I I FFE: 2115 III I I I I--- ' I (TYP.) --top - - - - - - MOM - ASPHALT DR -- -MON-- -M 21- m `_'•-' \ HAYWOOD PARK DR - - - - -' _ _ - - - --'----- - -� � - --- '- PROPOSED 12' WIDE r ' -� _ yNd� SHARED DRIVEWAY i -r- ---� �- --� r- i �I- 0.64 AC I I i I I I 1 I 1 I 1 1 28090.8 SF I I I � III III 1 I _, III 9 FFE: 2103; �� ,/ / 4 1 Ili i j III --i III I i I I ; i I I /i, J 1- -- `\\ I � I I OI 1 , 1 I , , I I ,, ,•.� �`. ., I ' 86 A I I ( I 1 I Oi 1 1 10 1 1 0.64 ACI I 1 / 1--------------i I 0.86 AC I I i I 1 i 1 1 I I I 1 /.' .�' ---- __ •� 37485.8 SF I I I------ I I------- I I 28088.2 SF I -f � , ' - - - - - _ ).\ I I I I I I I 0.64 AC FFE: 2103 i�j /' �' _; /� - - - - - /� �\ OPEN SPACE FFE: 2102 0.66 AC I i I '`: ' ./� , / 1 I 0.59 AC 1 I 1 27768.2 SF I - - - /' ,' &_::- - I I 28936 2 SF - - ------ 1 ./� ; I I� � I COMMON AREP I----- I I FFE: 2103 I I I 25563.2 SF I I 1 FFE: 2103 1 _. 1 FFE: 2103 "r PROPOSED 30' I 1 I \ ; / ' I I ► I L- L' I L ,, \l__a_;'�' /% DRIVEWAY EASEMENT �_ 1.12 AC Lit-__=i� ► 4- 10 (TYP.) 1 I I 1 _ -____- \\\ \ 15 48777.7 SF J _J (__ ��� _ i / /� \ FFE: 2121 0.66 AC I -------_---- ------ -J I -PROPOSED 35�\ 14 28725.2 SFJ FFE: 2109 CUL-DE-SAC\ RADIUS\ 10' (TYP.) 0.57 AC 13 0.70 AC I I j __I I 0.68 AC \ \ 24789.6 SF`s 30301.3 SIF I I I I 29784.6 SF \ \ FFE: 2110 I FFE: 2094 I 0.60 AC I I FFE: 2104 \ \ \ i f ► ► FFE 42099 I I I f \ \> / PROPOSED SINGLE FAMILY UNIT R 0 L► I I I ► I ► 12 \ \ \ fv "/ (70'X40' PAD SIZE) (TYP.) 14 LA WI D T 11 I ► \` \ \\ / / 15' (TYP SrhAs 34 _ PROPOSED 12' WIDE 3R 2 ------- ®- / DRIVEWAY (TYP.) 7,12' LANE W PTH I j r------sY-d�_ �- -»i / PROPOSED LARGE DECIDUOUS 'R2� TREE; 27 STREET TREES Q ►I► / / REQUIRED ALONG PROPOSED I 1.09 AC I ► �' HAYWOOD CROSSING DRIVE. I 47355.1 SF I ' SEE PLANTING SCHEDULE I FFE: 2096 I � 48551.7 SF / // I I 16 I I FFE: 2102/// HENDERSON CO. BOARD OF PUBLIC I III ;_ / PROPOSED 100' CENTERLINE SCHOOLS 17 PIN: 9650262638 CURVE RADIUS DB: 824 PG: 213 I I PROPOSED 16' WIDE ROADWAY (PRIVATE); i III /moi I / I � TO BE NAMED "HAYWOOD CROSSING DRIVE" PROPOSED PROPERTY LINE (TYP.) L_ �' PROPOSED SETBACK LINE (TYP.) PLANTING SCHEDULE SYM. I QTY. BOTANICAL NAME ICOMMON NAME SIZE I *CALIPER HEIGHT TREES BN 22 Betula nigra River Birch (3 Stem) B&B 2" MIN. 12' Min. MA 16 Magnolia acuminatae Cucumber Tree B&B 2" MIN. 12' Min. BN 13 Acer saccharum Suqar Maple B&B 2" MIN. 12' Min. NO. INO. I DATE I BY REVISION DESCRIPTION � W Q Z U� 0 OJ J _ U) M W z >0 < w C) wC) 22! >O w = Q U= O ISI U) o N V J U � Q N 0 U Up O U M U) x O � a 006 0 o u, z a0000 N Q Z U _ � Z �Za W = 0 0 U 1 00 4 > w z W¢ cn WW z� F11 Y --i v] � o W� � 3: J W O w 0 Z Q a - Lu I- U) Q 75 SHEET C-101 U Q Z OJ J _ U) M >0 < U C) wC) 22! >O m = Q U= O Z U) > V J U � Q Z 0 U Up O U M U) Z OQ z O 006 0 U) u, z O OfW Q Z p _ � Z LLJ W = Z Q a - Lu I- U) Q 75 SHEET C-101 2 _ U) co < w wC) 22! C) w m = 6 > > U 0 Z DO ZF_: Q,t 7q z w LD 0 LD u, z zoo M p Q 0 w o Q w w O wo J ap L? 0 0 0 0 U 1 00 4 Z Q a - Lu I- U) Q 75 SHEET C-101 I PLAN I I 80 0 40 80 160 I IPS GPS STATIC N: 606546.80 E: 950752.76 RAPHIC SCALE 0�6IC IAWA A 80 FEET - - I EL: 2096.54 \ P B: 032 PG: 8519 SANITARY SEWER MANHOLE I \ TOP EL: 2086.45' I I I I SINCLAIR, FROSTY A; FROSTY A SINCLAIR \ \ I I REVOCABLE TRUST s I PROPOSED SEWER DIB: 14315 PG: 204 \ --�- I ON LINE LINE A (TYP.) PROPOSED WATER \ (SEE SHEET C-107) LINE (TYP.) ` (SEE WATER PLAN) I I I I 1�^INT- I BLUE pq l I �--ter I.E.: 2 89.81' �/ _ ^ \ I � I 9 I __ I_ I� �--- =� � r i I -�\`\ \ \\\ \ � \ LOT 2 I.E.: 2ds1.5 '� P` --/'r I II I \\\ \ �\� T RASMUSSEN, PHILIP M; EXISTING WATER LINE I ,, L C I /� I I \ \` -\ RASMUSSEN, PRISCILLA A / c I /-____� I _/-- I J �_> _ }-�C PIN: 9650161982 r._ I.E.: 2891.52'?_ - - ------ -� + I I DB: 1370 PG: 471 0.69 AC •� 1 29969 7, S _I- t I' 0.59 AC FF10 0.59 c Z I 25809.0 SF 'I Z APPROXIMATE ISTING E: ' 45 RIGHT-OF-WAY - -2 824. SF I I FFE:. 211 ' I o / 3 / m I I , I I?' r I I\ I I I I I (TYP.) I I _ SANITARY SEWER MANHOLE TOP EL: 2084.72' 12" PVC IN (SE) I.E.: 12 2077.53' PVC OUT (NW) I.E.: 2077.49' � L I EXISTING 100'I I I AS ~ 2+Oo7 + 0 '2110 RIGHT-OF-WAY (TYP.) I `� I L E l0 1 I�HA qR i I, EXISTING 20' SEWER EASEMENT (TYP.) I 2110 + I/ CONSERVING CAROLINA z I \ I \ o - PIN: 9650059838I I 1 li �I\ �1 I i 4 _ 1 DB: 28 PG: 552 5 2105 _ ' / I 1 I \\ c_ I ILL \ 1 III 2100 28088.2 SF II t \ 0.86 AC %� / I I - -� h 0.64 AC I FFE: 2103 °t' % I B 37485.8 SF // �-0.59 AC \ - - SANITARY SEWER MANHOLE o I /� I I \ - ^ FFE: 2102 0.66 AC I r 25563.2 SF FFE 82103 TOP EL: 2088.81' I I i I I\ / _ - - 28936.2 SF- - - I -T _ _ <I I I , 12" PVC IN (SE) I.E.: 2078.14) - +00� =FFE: 2103- _ I -FFE: , 2103 12" PVC OUT (NW) I.E.: 2077.93' �� I I I \ /, - - �_ / - i / �- 1- 00 KNOLLS DRIVE I ► II �'/ �'� �. --, - -- i20WI / • ' I _-� � ; / I • ,7 / � ��►;, I%6� °�; � � /•� .,�•cG- =�! � / �// SANITARY SEWER MANHOLE-� I' / , R,� ` \ 1 / r ; TOP EL: 2089.66' �� • I U P � I 12" PVC IN (SE) I.E.: 2078.72 I s I ( L jI11I\ /' �-- -- -�\�� ,� ' /i//� / // 0.66 AI 12" PVC OUT (NW) I.E.: 2078.72' I / /� ��� ��„rs �� \ l / 14 28725.2 Q IT - - t FFE• 21 EXISTING 60 I N I � i III /Irk I /: � � � J/ RIGHT-OF-WAY (TYP.)IV If 1 01 EL: 2091.30 I I / / � N ��'J-' � II/ ) R 6F EL: 209 I I ( // / 24757.6..5 � PROPOSED JACK AND BORE V. EL: 2086.168 I /I I / IIIIVI /� AC - 2 .6 F \ �\ F / IIP �, EI • �Ra �. / 0 8 AC / I TO INSTALL 24" STEEL I I I I VIII / / 303 .3, SF/ o /o o �� I I F ; 04 / �\ - / , I I I I I ,FF 20Y4 ENCASEMENT PIPE (TYP.) I / I I / RY SEWER MANHOLE SANITARY TOP EL: 2087.59' I oA 12" PVC IN (SE) I.E.: 2079.34' - 12" PVC OUT (NW) I.E.. 2079.16' I y I 3 I i / J L =- I I k0�' i / II I CONSERVING CAROLINA I I / I \ - � S p \ PIN: 9650059838 I I I I ) / - �;co \ D13:28 PG: 552 /- / _�/ / I I� ► I I r� i i I �� �' �i I I i - /� ,0.�� PROPOSED SEWER I y ► �I I \ l / / LINE C (TYP.) EXISTING SANITARY I I I IIIII�r / 1.0 AC / - I I / / / (SEE SHEET C-109) SEWER LOCATION I N I I I i Ilii I 4F E:5 1 96 I I� I 15'11 1 c Y / I II I r � I II // 4 551 sF \\l / / / �FE: 210 11 I III P I 16 I I / / ON - ' � N V_�SANITARY SEWER MANHOLE / I I I.E.: 2093146' I I I I I li ' 1 " .6 . // TOP EL: 2110.75' I.E.: 209.18' I I I I '�� I ^( `II //I I I / // // / ;('� PROPOSED IPS GPS STATIC I 1 I3I_I iIr If STORMWATER STORM WATER PIPE 24" CMP N: 605761.78 224" CMNLINE (TYP.) E: 951470.12 I.E.: 2109.39' (SEE STORMWATER & EL: 2096.54 GRADING PLAN) / x // SANITARY SEWER MANHOLE- TOP EL: 2088.70' ssyy I ► /; Ire I\�Y / �I /,/ \ \/��/ PROPOSED PROPERTY LINE (TYP.) L/ s� SANITARY SEWER MANHOLE / TOP EL: 2108.95' -W-----W-----W-----W`M- -M - I I --Ai _-Ai ___ � I I I I 3 I I I I 3 I I I \ BUSH, RONALD E; BUSH, JOYCE R ADAMS, BRYAN; ADAMS, PIN: 9650174702 \ DB:534 PG:389 \ S BENNETT, LARRY; THE LARRY AUSTIN, BRUCE; AUSTIN, THERESA 965017 PIN: 9650176986 BENNETT LIVING TRUST PIN: 9650173407 DB: 1616 PG: 518 PIN: 9650171258 DB: 1586 PG: 673 \ I DB: 3259 PG: 154 PROPOSED 20' SEWER \ PROPOSED WATER \ EASEMENT (TYP.}--- / PROPOSED 30 I SERVICE (TYP.)-_------ DRIVEWAY (SEE WATER PLAN) _ - / EASEMENT (TYP.) --�=-_-� 1.11 AC \ / /i r_ 20 .4 7.2 SF/ FFE � 212-e- -- 4- -F _ 1.00 AC == 1 -.r ���-� �' - '' / ,/'/ 18 43543.0 _SF--'.� 25' TROUT WATERS �_- - _ _-- BUFFER _FFE_ 211 - - - / ' jy.' j j //. % �' , 2 -_, ,_ _ ;_,-- \�///,.// 30 PERENNIAL STREAM ��BUFFER / \ � � ' ��~�\\ -/ ' PROPOSED SEWER SERVICE (TYP.) /,, / / EXISTING STREAM CENTERLINE; /; _ - _= = =' ; ;�� \\�\ / `•� /' CLASS WS -IV (TYP.) 41 .01 PROPOSED SEWER MANHOLE (TYP.) SANITARY SEWER MANHOLE \ / TOP EL: 2118.74' 1.12 AC 15 48777.7 SF�'��/ FFE; 2.121 PROPOSED SEWER / LINE B (TYP.) (SEE SHEETS C-107 I THROUGH C-109) / -10 s P\\N PROPOSED SINGLE FAMILY y UNIT (70'X40' PAD SIZE) TYP. SANITARY SEWER MANHOLE TOP EL: 2119.97' PROPOSED STORMWATER INLET (TYP.) (SEE STORMWATER & GRADING PLAN) HENDERSON CO. BOARD OF PUBLIC SCHOOLS PIN: 9650262638 DB: 824 PG: 213 NOTES: 1. SPECIFICATIONS AND REQUIREMENTS OF THE METROPOLITAN SEWERAGE DISTRICT SUPERSEDE ALL OTHERS IN THE INSTALLATION OF THE PROPOSED EXTENSION. 2. THE INSTILLATION OF THE PROPOSED SEWER EXTENSION AND ALL PUBLIC SANITARY SEWER WORK ASSOCIATED WITH THIS PROJECT TO BE PERFORMED BY NC LICENSED UTILITY CONTRACTOR. 3. PROJECT SITE IS LOCATED OUTSIDE OF 100 -YR FLOODPLAIN. NO. I DATE I BY REVISION DESCRIPTION ' ^ (J1 w o. kn U� U O J J = < Wo � w z >0U Z U a 0 O Co m z m� U) Q wU �= LJ � Z C) o cr � N U) Q N 010 zF_.: �x Q m UU) O 0 U O � a 0 �(s Z (!1 �Ioc oc N 006 w� 2 Z �0 w w a Q Z w 0 _ � Z w w W r� v O W Z Q J W 3: W Cn SHEET C-1 06 U Q Z O J J = < Wo o O. >0U = 0 O Co m z m� U) Q wU �= O Z C) M cr � p� U) Q Z zF_.: Q m UU) O 0 U o 2 (n 0 U) Z OQ O 006 w� 2 �0 w LL Q Z w 0 _ � Z U)= Z Q J W 3: W Cn SHEET C-1 06 M rn = < � U) 0 oN = w w Co r° z m� w wU z M cr � p� m zF_.: Q m z w 2 o 2 (n z o -a m w� 2 Q w Q O w J (13 Z Q J W 3: W Cn SHEET C-1 06 _. co 0 0 T W m J Z 0 0 Z J 0 LL 0 z i ,, ; -- ' = -------------- NOTES:PLAN W o-------- RIGHT-OF-WAY EXISTING 100' I. 2091.52 (TYP.) _ - ,-------------- W U PROPOSED MH #2 =PROPOSED SINGLE FAMILY 1. SPECIFICATIONS AND REQUIREMENTS OF THE METROPOLITAN z I �IIIIIII I/ / / �' - _ �- STA. 1+85.16 Z SEWERAGE DISTRICT SUPERSEDE ALL OTHERS IN THE w U III / / -� - SEWER LINE A UNIT (70 X40 PAD SIZE) TYP. INSTALLATION OF THE PROPOSED EXTENSION. [� a PROPOSED MH #5 I i4IIS z 2. THE INSTILLATION OF THE PROPOSED SEWER EXTENSION AND ALL STA. 1+96.81 I ` I ►IiIIA 1 m PUBLIC SANITARY SEWER WORK ASSOCIATED WITH THIS PROJECT SEWER LINE B I I l JIlil�L I I / li IIS IIII I I I ► ► ! ` __ I ' i I I I ,' g I / TO BE PERFORMED BY NC LICENSED UTILITY 3. PROJECT SITE IS LOCATED OUTSIDE OF 100 -YR CONTRACTOR. FLOODPLAIN. o I I I I / I ISI I� 1111 I / / � � \� _ o I/ I III II ((/ PROPOSED SSE _ \ , -� - N \\ N SANITARY SEWER MAN HOLE I\\I \\\\ RV\\I\�CE (�-T--_YP. SERVICE O U 00 TOP EL: 2084.72' 12" PVC IN (SE) I.E.: 207753 12PVC OUT (NW) I.E.: 2077.49' PROP S WER I PROPOSED WATER uo pC a �E LINE A (TYP.) SERVICE (TYP.) 50 0 25 50 goo , (SEE WATER PLAN) o � � '- 2110 - _- __ � U GRAPHIC SCALE DIVISION VALUE = 50 FEET I I ' I I ilZvl� I ASP ffALT Ir I � - 2+00� 3+00 Z W 172.39 LF 8" DIP ,o / BLUE j - 142.21 LF 8" DIP - I --w C T/1 V1 Z 20.33 LF 8" DIP N I I I I _ / I I I I 0 ` I. 093.06 - I ' �� w w ---w------ -r_ _ _- - - - - - 0,_ PROPOSED MH #3 w w I I \ I I 57.91 LF I- 1\ r- ISTA. 3+19.31 \�\ //- �- 4 EXISTING 20' SEWER N I i 8" DIP \\ 1' _- SEWER LINE A ~I Q EASEMENT (TYP.) I I I I \\ \� , 21'1 , �� _----' o o / _ --- EXISTING 60' I N I I i �I\ ^\ i 4 1 / _ __ I ,. 2105 j 11 PROPOSED 20' SEWER W RIGHT-OF-WAY (TYP.) I I I I �l I \� \\ I �; I 5 130.58 LF 8 DIP ___- EASEMENT (TYP.) I I I I \ LF 02 \. \ \ 87 I 1 _ I \\ I I , - - 210 0 JA I I 8" DIP \ Q. I P p\\\ \ _I PROPOSED MH #2A I STA. 0+38.95Ik ---- oo \ _ SEWER LINE A - _ - R SANITARY SEWER MANHOLE TOP EL: 2088.81 - I I I ��\ __ ` t ' 'i �� � � ii'%' � ' < ' ----- i (i0 �--� �- 12" PVC IN (SE) I.E.: 2078.14', 12" PVC OUT (NW) I.E.: 2077.93' I / I 1 � ' �' _ - I I I I 1 �i-- - i o0t.-' ' ��i'/'' \ d sow J 1+00 now \ +' o - 34.95 LF 8" DIP ♦ Q y �� �� -- ,, �i ; ; �-� ,_, "AYWOOD co4 - WOOD KNOLLS DRIVE I � vow _ = :.1= = = V Z t� Row� -__R I , I I / ' PROPOSED MH #6 �.--_1__- / �' ��1 � .♦ � ♦ - l ♦ $ ,. <I k0-- ♦ �,,f,--'� 6 %' ; ; -�_ -� ,' �� %'�- I < <- EXISTING STREAM CENTERLINE; Z J O J - J I I It STA, 2+58.71 I'\-�1 ,1/ , / ���� __j-- ---� \ 1 \ .- - 0 SANITARY SEWER MANHOLE I �E Tl . I SE WER LINE B \ / I I 1 __ ___� -_-_-_ ____ _,-; \I _ S / '%� - - - - - _ ' /�-- y�i / _ CLASS WS IV YP T �^ Vi TOP EL: 2089.66'" 12" PVC IN (SE) I.E.: 2078.72' ' 12" PVC OUT (NW) LE.: 2078.72' ss�y I j ))� I ' I �� \ \ / p Of RETE�` - - ______-_-- _- - - _- - - - 00 �♦ \ ` l ' - _ / %'- 30'� PERENNIAL > O - (� I l`'�ii ---PROPOSED SEWILR /��� ���� ''� - : - ,' �, - `"� � � � STREAM `'° I m = PROPOSED II JACK AtVD I ! ixi PROPOSED MH #1 o LINE B (TYP.) ,,/ / �,\\;, ;; -_ �� ;�---BUFFER I BORE TO INSTALL 24" � I I� ► I II► I /, STA. 0+00.00 � (SEE SHEETS C-106•,r,�l,- � ,, - � Q STEEL ENCASEMENT PIPE � � � ! i SEWER LINEA I � - - ,, � THROUGH C-108) ,/ � _ �-=-:- � -^ 25' TROUT WATERS ('� _ 0 BUFFER z NO. DATE BY REVISION DESCRIPTION W C/) [-.- C/) Q Z < C) SEWER LINE A PROFILE W z SEWER LINE B PROFILE 0 SCALE: HORIZ. 1"= 50' J SCALE: HORIZ. 1"= 50' V U) 0 VERT. 1"= 5' Q w VERT. 1"= 5' O Q Z W r-) L °' 0 0 O Q J m� O o6cNy� W Z of =�oo M N N 0 L.Lw ° C) WW N� W A c•o• of F- W 2115 m W W W J J2115 J Q Zw 0+ � r7 rn = T- W O 0- J [ifLIjI- � c Qz Z� O:f �� 04 0 �Nr7 �V7N 0 � >- Z LdOIll U w Lid LIJ= O u)T_ mnF_ m J Ld W 000 O 41z: WW 0W Nn nW X000000,0 w NW000 0No� n+J W Z 2105 W -o U) o co co 6 2105 2110 o7 V) C°�°o � 0oo 0 00 . N O 2110 0 = 00004 o N M i Qw OONOoa000 O O O OJ WZO HOZ (nH _ V) �0 N � 0O 00j W w wUo 0 , n + ++J O HO / -.0- o0O O WZ N J� o Q�00 ww z o 'o O o W W ? W (n-? �`'000 2100 v orn Ow0 O ? Q< m 2100 w� co 0 z2105 cm o � -EXISTING GRADE (TYP.) 2105 o) 00 (n J .. O Wz n U) ojj iW Q0 LD oLv m o n zowa- Q �(nNNHZZZZ / QON0 WOQW F- o o U o U IL°r°d 2100 I ,, 24" 130.58 LF 8" DIP 0 5.16% 2095 0 0 w Z 2100 / 2095 O Q mj \\-APPROXIMATE O XIMATE LOCATION OF EXISTING 6" DIP WATER LINE (TYP.); let J Q _ 2095 3' OF COVER AS UMED OV R WATER INE 2095 12090 2090 LL w EXISTING 6" DIP WATER LINE (TYP.) O z ASSUMED TO BE 8" DIA. WITH -R XISTING GRADE (TYP.) J 3' OF COV :_ 2090 2090 2085 2085 0 Z W PROPOSED 8" DIP 172,3 LF 8" Q WATER LINE (TYP.) J 2085 34.95 LF 8" DIP 0 18.00% 2085 EXISTING SEWER 2080 87.02 LF 2080 8" DIP ®2.99 (n MANHOLE (TYP.) STA 0+00.00 20.33 LF 8" DIP ®5.66% SHEET TOP ELEV: 2088.81 57.91 LF 8" DIP 0 3.07% INV IN: 2078.14 (e) INV IN: 2079.43 0+00 1+00 2+00 3+00 4+00 5+00 INV OUT: 2077.93 (e) 0+00 1+00 2+00 3+00 4+00 C=1 07 Z 0 0 Z J 0 LL 0 z _. 00 0 0 T W m J z F- 0 Z J J LL 0 I PROPOSED SINGLE FAMILY PLAN PROPOSED WATER\\\\ \\\ W o LINE (TYP.) UNIT (70'X40' PAD SIZE) TYP. ROPOSED SEkR 50 0 2s so -- ----- _-� ;� - (SEE WATER PLAN _ - , �= =�- -'.dw goo --- --------- INE A (TYP.) � ' ��- m I \. -- _ _ _ _ -_ _ = 273.27 LF 8" DIP _ -- �� kpp� � �� e-•'�, � \� � - _ � ;� U a - (SEE SHEETS C-105 AND C-106 ,/ m PROPOSED WATER GRAPHIC SCALE_ _ _ _---- ____ _ ____- � 18 __________�____ _ �6 -� __ � � III I / 1 L�' // SERVICE (TYP.) ---DwISlo�vaL�E_= -_--- i / /i\\�\'%/' II ► \`` (SEE WATER PLAN) -____ 214s___ ___ _ _ _ - _ -__- __ - / / = --'''' \\ C7 it I li i \ 2 I �c\ PROPOSED S ORMWATER �- �,� -ri,� Vii`\� �/' ,'� ,, I --I \� \ PIPE TYP. __-_-_- -- - ___ __\ \\��c ,,� \�� �i�-' \ ;� ��;!\\� /// ,-�•' N \ \ \ \ (SEE STORMWATER & 2 GRADING PLAN) --- ----- �'�� � ��♦.% �� I ,+• %' /'- =I— _Moa= ��'� ' PROPOSED MH #13 _ ®CB _-- \- i STA. 16+01.30 _� 2110' � '_ -= �? ��_`\ — �'_ —�� ,,'/i,�,�______�____ ___-�'�%� SEWER LINE B a _ - 84.62 LF 8" DIP __� --- - `3.x"00 -� /i',./�i�� I===- � z - I Tub �. � Zp� a `` 3 _- - - _- own /mom IPROPOSED MH = - - - - - r-/ #122100 _____ �1'.•_l STA13+2629EXISTING L //ri�� -- _\/�= - _-" ..2 i,_- -_ _ _--_ - --_w — --_' , -' '\ h' ' _ X --y-' p p \-v..► ���.►��t 2+0 SEWER LINE B STREAM ol CENTERLINE; W W ¢ I �lop' -' -�—' ��y�\ \ I / (CLASS WS -IV) Z w \�\� —' 2110 ', 69.28 LF 8 DIP �; r �'--_�'';,z-----\-- 212.28 LF 8" DIP (TYP.) _—_ C7 210 5 - -' - - -T0P-,e 4t._ _83__ ��rx�i/ �� - - ��__�--�- -� ;- �t_ PROPOSED MH #11 2100 225.43 LF 8" DIP�o\ ,-, _-- �� CO ♦ 'i►/ \ / �' //� �� �� �/ !moi/ i fes_ STA. 11+10.00 ,,-' ,-' ,�_�' SEWER LINE B � � �� ' ��� _ PROPOSED SEWER LF 8 DIP 00 .�.�,' y �,^ ``\ \ l ��= L.00 ' / ,� �� �— �I '_�.'• ='W' -:�-�, y• 'J % `, B TYP. (TYP.) � �$+pp ==2 �_ '- ti #10 �- -_,. PROPOSED MH ,/, ��'•� O �� _� =SINE __194.47 3+ -_ .- - 00 - _ _ - - _ r IS I , _— ,, �/ _ `" �� ♦ > , - _ _ __ ;,%_J /�_` / ROPOSED 20 SEWER - / i "__ i _` \ STA. 10+21.38 � `� � SANITARY SEWER '� _ _ _ _ _ ti TOP EL: 2118.74' MANHOLE y _ _ � � cc "' ' '/ _ _ ''�='- S �kp��`�� PROPOSED MH #8 �� ;====''1'�- -EASEMENT (TYP.) -' SEWER LINE B �� _;;_-_\ NOTES: = ---_,� \� \ �� I \ �'-- -STA. 7+22.68•�'' _ _�_=_= Ir I - ,r 25 TROUT - \-%>;4 SEWER LINE B - �i +�04 '�'��� ''�- -,� ;'" %%-%%%�1� 1. SPECIFICATIONS AND REQUIREMENTS OF THE METROPOLITAN (� - -�- _ .� WATERS FFR--,. 1 / ♦ - _-__= --' 00 - - ' 1'� '-" / 6 '� � � - / / 15 - '' �� \ SEWERAGE DISTRICT SUPERSEDE ALL OTHERS IN THE INSTALLATION OF THE PROPOSED EXTENSION. Z J J O Z _ J ,. / ♦ \ ,-••rte--� h ; ;,,,� ��� •• .:�.- , / I 2. THE INSTILLATION OF THE PROPOSED SEWER EXTENSION AND ALL _ 0 172.48 LF 8 DIP -- _-=- = r• at %- - -_ / I / �' �' �' %� PUBLIC SANITARY SEWER WORK ASSOCIATED WITH THIS PROJECT (n 0 _� ,0. ��; \ , \�,�� / \\\\\ \ -�� ,' - -_/ / / i I / - / / , , � / ^ PROPOSED MH #9 \ STA. 9+50.11 \ ' '�' / ��' TO BE PERFORMED BY NC LICENSED UTILITY CONTRACTOR. 3. PROJECT SITE IS LOCATED OUTSIDE OF 100 -YR FLOODPLAIN. > O U R 7 '--------------RO OSED SEWER -' PROPOSED MH # ,/ rl ,' /',' ,' _.--- SEWER LINE B 0 --------- SERVICE (TYP.) ,/ ��,� STA. 5+26.21 _ �'� ��\--�� / /� I ,//�/�// �� �' m > _ _ i SEWER LINE B �� 30 PERENNIAL STREAM Q BUFFER 0 �= z NO. DATE BY REVISION DESCRIPTION LIJW WQ z SEWER LINE B PROFILE C) SCALE: HORIZ. 1"= 50 T U-) m 0 V 0 VERT. 1"= 5' o0 N (n 0 T- w 0 U) Z 2120 m ooz w+ :3Ld 2120 0 Q O Ld N 60 o�w � 0 06 U) z0 OQ�12 0 � � (6 Lu c- U) n � z W 2115 m m ��rnUJI AN �+ JLd 2115 = Q Z w z (0 OUJI o �cn 0- O ILLI W J J o0- � M07 2 0 000 ILLI 0 Q 3: 0- j w = BOO O ON NON Ld IZ (n (n HZ a 2110 z 3:� O w �Lu 04 Cl o + LLJ 2110 Q J m 1.O0 Z#tZ N O 04 OVj = T �ui0 (n J ..� w-0 o �, o = w w o W 200�n00 � �NO)04 O 0 OQ�jj 00 z o w w wU w O O O�� N w F— � >: NH JZO .w?0 O jj �(nH-- p �� o 2.2 1P p w �M+� z 00 z Q� 2 �N� 2105 = •rn N cn + w—O a- F— LF $" 2105, z 00 dj 9 o z w 0 M 04 N 0->:>:0N>04 p Q w Q w � -d (0 ON 0 <» 0 pQ o�wZO -MF— m -- 2 2• 9 1.7 \ IP 2100 O a w 2100 z m 0- U) w J LLI 225.4380 LL Z 2095 IP ® 2095 O J 194.47 Ll- MEESE= DIP ® 0-91% „ `.46% w Z z 2090 \P @ 2090 Q LLI EXISTING GRADE (TYP.) 69.28 LF 8" DIP ®1.30% U) 2085 2085 SHEET 4+00 5+00 6+00 7+00 8+00 9+00 10+00 1 11+00 12+00 13+00 14+00 15+00 16+00 16+50 1 Cml 08 1 z F- 0 Z J J LL 0 I x 0 z W 0 W 3 co 3 0 U) co W m J NOTES: EXISTING STREAM CENTERLINE; -` %=---- ��'/ co PLAN ' —,—_ _- _-,, �' 11 -.!� " I ;,- -%' �� -- \ J �� �, -�- �-, v1 011 loom�= + /. ,, ,_ / \ + __ _ / - .,-� ♦ ,� ;� CLASS WS -IV (TYP.) .-= =_=- _, - _ -- _--- - �i - _ ��,� o ',` � I � I �.��- �►-- _-� -�-_ - = / / � ,. ,•�._. - �I ;_ PROPOSED SINGLE - __ -'UNIT (70'X40' PAD FAMILY' SIZE) TYP.,cn - ' 1. SPECIFICATIONS AND REQUIREMENTS OF THE METROPOLITAN ---___��� ,I� ��� I co ��,.- _ ♦ _ _ -__�- //�/moi ; ♦- �� - SEWERAGE DISTRICT SUPERSEDE ALL OTHERS IN THE 25' TROUT WATERS / -_� 9=' -- ' ---�- -� '♦� —��' `'"'� "' - -� - �� J%.-/ / �� ♦ ` �� / /' '' '' ' / �'' '' ' '� , 15 - - % % � INSTALLATION OF THE PROPOSED EXTENSION. 2. THE INSTILLATION OF THE PROPOSED SEWER EXTENSION AND ALL BUFFER:�/ I / I'\ i �'�-:�'-•• / /• 1� \ ,�'' ��'/' I �.���%�/ , // // // // \ ♦ ,//����- 1 _ PUBLIC SANITARY SEWER WORK ASSOCIATED TO BE PERFORMED BY NC LICENSED UTILITY WITH THIS PROJECT CONTRACTOR. 30 PERENNIAL STREAM _ ,\ � �� 1 �.�_ _ I � � � ________________^�� \-T `, �, � ♦ � /�,, j �� � �_ _� �� �� // �.- / _ _-_ / ��� �� /��/- I /,. �„ _ / / 14BYFFER 3. PROJECT SITE IS LOCATED OUTSIDE OF 100 -YR FLOODPLAIN. ' x - II 1 , �, , ---------------- Z PROPOSED MH STA. 0+00.00 #1 SEWER LINE ° C oo °� " ROPOSED EWER / /��.. --LINE B (TYP.) /' I I l i� / I 11 �� SEE SHEETS C-106 /'-� THROUGH C-108 ) N 13 w PROPOSED 20 SEWER a EASEMENT (TYP.) Z w I PROPOSED SEWE 2 5.2 LF DIP . �-� , ssyy P W w SERVICE TYP.10 �x� z C7 100,00, 0 100, SANITARY AR SEWER MANHOLE 21 W� ' � x00 / 100, PROPOSED STORMWATER PIPE (TYP.) I;• O co - S / (SEE STORMWATER & GRADING PLAN) /// r// I I _ ' I I I - S •� I S 6+00 PROPOSED WATER � I I I I I �Fo o fi — S I \� =5+00 / LINE (TYP.) �y PROPOSED MH #14 / 1 1 _ — _ _ (SEE WATER PLAN) STA. 3+01.56 / / SEWER LINE C I j i / ,' I �/ \ I I , ,� U Q z J z I I I ►�� �� I I I � P 0 0 ED EWE I I 1 PROPOSED MH #15 I ` 0 J O PROPOSED WA�fE� SERVICE (TYP.) I , I ,- I � ,- I / / LINEC (TYP.) I � �, I - /� // // // STA. 6+16.57 / / �\/ / / , SEWER LINE C ��� // 50 0 25 50 100 — � D � I (SEE WATER PLAN) l I I I I, I r - I l shy >0 Q I I I I I I I / 16 I I / _ I I I — — \\ / // N // SANITARY SEWER MANHOLE GRAPHIC SCALE DIVISION VALUE = 50 FEET O E U EL: 2110.75' TOP s z NO. DATE BY REVISION DESCRIPTION U U O Q Z SEWER LINE C PROFILE Z U 0 SCALE: HORIZ. 1"= 50' -1 U U VERT. 1"= 5' w w (n z Z J �w 00 0 Q O PROPOSED 18" HDPE rn �o 006 w w �� _ STORM PIPE (TYP.) 04 O U) 2120 �o�� 61?�� �w °� >� 2120 Q z W Q NW O Lf) j N0 Iwo Q Z o . N cfl .. .0. 0/ _ 5_ O,^ 2115 w a-2115 L 3 z EXISTING GRADE (TYP.) a_ V) oma? �' < \ U o CR = w w o U Q w °�° m V z p} W W W -' w a' 2110 www PROPOSED GRADE (TYP.) 2110 0 z m z a� � J J J (ifct ct - ?J O Co z pp p LLI — 0 — 07 z p U I- -U) 0 0 z W p a w a w o � U LL � c CU _ d www O LLI 4k U) N (A .4 �w LLJ icor = co o vi 0oo 275.22 LF 8" DIP C� 0.60 20 2105 rn o00 000 Lo N oo-mms2105 = I, O O N 00 00N � o j N + W 0LLI 0>OO V) J "D w 0 M OOJZLLJ-Z •O 0..LLJ 2100 0 z z 2100 LL Z CL m mmo CL (n NNI—ZZ Z O�Q O J � O ro 20951 2095 z 3:Q W 1 J U) 20902090 97.56 LFisommmommmmo ROPOSED 8" WATER- LINE (TYP.) SHEET 0+00 1+00 2+00 3+00 4+00 5+00 6+00 10+00 7+00 8+00 9+00 cmi 09 z 0 c� z J C7 LL 0 z TRENCH PIPE WIDTH EMBEDMENT MATERIAL \\ O \ SECTION C -C N.T.S. CASTIRON FRAME & COVER 12" MAX. BRICK ADJUSTMENT FLEXIBLE MANHOLE SLEEVE OR ENTRANCE JOINT I I MANHOLE STEPS SEE _DETAIL „A„ _ 4'- 0" _ MINIMUM LU va wa a' -U) a_ a? OOf Z we 0z< C7 OU U 2" GROUT INSIDE JOINT DETAIL "A" N.T.S. PIPE UNDISTURBED EMBEDMENT MATERIAL SECTION A -A MANHOLE NOTES: N.T.S 1. FOR MANHOLES LARGER THAN 4 FT. DIA., MAINTAIN FULL MANHOLE DIA. TO 6 FT. ABOVE INVERT BENCH. 2. FOR 5 FT. AND 6 FT. DIA. MANHOLES, USE A TRANSITION CONE TO REDUCE TO 4 FT. DIA. FOR 7 FT. TO 10 FT. DIA. MANHOLES, USE A TRANSITION TOP TO REDUCE TO 4 FT. DIA. 22' MIN. IN ROADS 4"MIN.CLEARANCE FROM BOTTOM OF COVER TO TOP OF CLEANOUT COUNTERSUNK PLUG 3"MIN. NOTE 2 ROPES BUTYL RUBBER SEALANT C A -' SECTIONAL PLAN N.T.S. 6" MIN. PIPE EMBEDMENT MATERIAL NOTE: MANHOLE STEPS TO BE VERTICALLY IN LINE WITH "INVERT OUT". STANDARD DETAIL Metropolitan Sewerage District of Buncombe County, North Carolina STANDARD MANHOLE DATE APPROVED: MARCH 2017 2.11 - 01 7 3/4" MIN. 4" OR 6" SEWER CLEANOUT RISER PIPE 1. ALL SANITARY SEWER CLEANOUT BOXES AND COVERS SHALL BE MANUFACTURED FROM GRAY IRON (CAST IRON) MEETING THE REQUIREMENTS OF AWWA C110 AND ASTM A536. 2. ALL SANITARY SEWER CLEANOUT BOXES AND COVERS SHALL CONFORM TO PARAGRAPH 2.01(d) OF ITEM II, SECTION VI OF MSD's TECHNICAL SPECIFICATIONS (MADE IN THE U.S.A.) 3. NON -TRAFFIC LOCATIONS; SANITARY SEWER CLEANOUT BOXES AND COVERS SHALL BE AS MANUFACTURED BY EAST JORDAN IRON WORKS MODEL 1566 (OR APPROVED EQUAL) 4. TRAFFIC LOCATIONS; SANITARY SEWER CLEANOUT BOXES AND COVERS SHALL BE AS MANUFACTURED BY EAST JORDAN IRON WORKS MODEL 1574 (OR APPROVED EQUAL) 6"MIN. WASHED STONE BASE STANDARD DETAIL Metropolitan Sewerage District of Buncombe County, North Carolina CLEANOUT BOX DATE APPROVED: MARCH 28, 2019 2.07-05 LOOSE INITIAL BACKFILL LOOSE INITIAL BACKFILL LOC 0 LOOSE INITIAL BACKFILL UNDISTURBED EARTH LIGHTLY COMPACTED LOOSE INITIAL BACKFILL TO TOP OF BACKFILL PIPE 7 UNDISTURBED EARTH LIGHTLY COMPACTED BACKFILL TO TOP OF PIPE UNDISTURBED EARTH BACKFILL COMPACTED TO 80% STANDARD PROCTOR TO TOP OF PIPE PIPE BEDDED IN SAND, GRAVEL, OR CRUSHED STONE TO 1/8th PIPE DIAMETER, 4" MINIMUM GRANULAR OR SELECT Pipe Size BACKFILL COMPACTED PIPE TO 90% STANDARD STANDARD DETAIL PROCTOR TO TOP OF EMBEDMENT PIPE SEE DETAIL 2.05-02 FOR Type 3 ALLOWABLE DEPTHS MATERIAL 4 350 53 61 a- 85 100 6 350 0 OF F__ MANHOLE 47 65 8 Lu STEPS 25 34 50 z 350 1 11 15 19 28 O 12 350 10 15 19 U 44 � 250 - 11 U 23 �� 14 300 z 17 o 42 14 z - 14 _ 27 44 Lu 250 - 11 15 24 Cn U 16 300 - 13 17 26 39 W 350 - 15 20 28 44 18 y O - 10 14 22 31 18 300 U 17 26 36 18 > - 15 19 28 O 20 250 - 10 LL 22 30 20 2 CENTERLINE OF 17 26 35 INLET PIPING IS 350 - 15 57< NOT ALLOWED IN 38 24 200 EITHER 12 17 00 QUADRANT C - 11 15 ADJOINING THE / 24 300 MANHOLE L 24 32 OUTLET. 350 PIPE UNDISTURBED EMBEDMENT MATERIAL SECTION A -A MANHOLE NOTES: N.T.S 1. FOR MANHOLES LARGER THAN 4 FT. DIA., MAINTAIN FULL MANHOLE DIA. TO 6 FT. ABOVE INVERT BENCH. 2. FOR 5 FT. AND 6 FT. DIA. MANHOLES, USE A TRANSITION CONE TO REDUCE TO 4 FT. DIA. FOR 7 FT. TO 10 FT. DIA. MANHOLES, USE A TRANSITION TOP TO REDUCE TO 4 FT. DIA. 22' MIN. IN ROADS 4"MIN.CLEARANCE FROM BOTTOM OF COVER TO TOP OF CLEANOUT COUNTERSUNK PLUG 3"MIN. NOTE 2 ROPES BUTYL RUBBER SEALANT C A -' SECTIONAL PLAN N.T.S. 6" MIN. PIPE EMBEDMENT MATERIAL NOTE: MANHOLE STEPS TO BE VERTICALLY IN LINE WITH "INVERT OUT". STANDARD DETAIL Metropolitan Sewerage District of Buncombe County, North Carolina STANDARD MANHOLE DATE APPROVED: MARCH 2017 2.11 - 01 7 3/4" MIN. 4" OR 6" SEWER CLEANOUT RISER PIPE 1. ALL SANITARY SEWER CLEANOUT BOXES AND COVERS SHALL BE MANUFACTURED FROM GRAY IRON (CAST IRON) MEETING THE REQUIREMENTS OF AWWA C110 AND ASTM A536. 2. ALL SANITARY SEWER CLEANOUT BOXES AND COVERS SHALL CONFORM TO PARAGRAPH 2.01(d) OF ITEM II, SECTION VI OF MSD's TECHNICAL SPECIFICATIONS (MADE IN THE U.S.A.) 3. NON -TRAFFIC LOCATIONS; SANITARY SEWER CLEANOUT BOXES AND COVERS SHALL BE AS MANUFACTURED BY EAST JORDAN IRON WORKS MODEL 1566 (OR APPROVED EQUAL) 4. TRAFFIC LOCATIONS; SANITARY SEWER CLEANOUT BOXES AND COVERS SHALL BE AS MANUFACTURED BY EAST JORDAN IRON WORKS MODEL 1574 (OR APPROVED EQUAL) 6"MIN. WASHED STONE BASE STANDARD DETAIL Metropolitan Sewerage District of Buncombe County, North Carolina CLEANOUT BOX DATE APPROVED: MARCH 28, 2019 2.07-05 LOOSE INITIAL BACKFILL LOOSE INITIAL BACKFILL LOC 0 LOOSE INITIAL BACKFILL UNDISTURBED EARTH LIGHTLY COMPACTED LOOSE INITIAL BACKFILL TO TOP OF BACKFILL PIPE 7 UNDISTURBED EARTH LIGHTLY COMPACTED BACKFILL TO TOP OF PIPE UNDISTURBED EARTH BACKFILL COMPACTED TO 80% STANDARD PROCTOR TO TOP OF PIPE PIPE BEDDED IN SAND, GRAVEL, OR CRUSHED STONE TO 1/8th PIPE DIAMETER, 4" MINIMUM GRANULAR OR SELECT Pipe Size BACKFILL COMPACTED UNDISTURBED EARTH TO 90% STANDARD STANDARD DETAIL PROCTOR TO TOP OF 0 PIPE SEE DETAIL 2.05-02 FOR Type 3 ALLOWABLE DEPTHS /� PIPE BEDDED TO j j SPRINGLINE IN D / GRANULAR MATERIAL TRENCH WIDTH /\ \\ MINIMUM 4" BELOW INVERT OF PIPE, THE MINIMUM TRENCH WIDTH SHALL BE COMPACTED TO 90% THE NOMINAL PIPE DIAMETER PLUS 24", EXCEPT THAT THE MINIMUM TRENCH PE 5 %\//\/\\ STANDARD PROCTOR WIDTH SHALL NOT BE LESS THAN 48" IN ANY CASE UNDISTURBED EARTH NOTES: 1. MINIMUM ALLOWABLE DEPTH OF COVER IS 3 FT. 2. IN ROCK OR WET SOIL, PIPE MUST BE BEDDED IN AT LEAST 6" OF CRUSHED STONED EMBEDMENT MATERIAL BELOW THE INVERT OF THE PIPE. 3. GRANULAR MATERIALS ARE DEFINED PER THE AASHTO SOIL CLASSIFICATION SYSTEM (ASTMD3282) OR THE UNIFIED SOIL CLASSIFICATION SYSTEM (ASTM D2487), WITH THE EXCEPTION THAT GRAVEL BEDDING/BACKFILL ADJACENT TO THE PIPE IS LIMITED TO 2" MAXIMUM PARTICLE SIZE PER ANSI/AWWA C600 4. THESE PIPES ARE ADEQUATE FOR DEPTHS OF COVER FROM 3 FT. UP TO THE MAXIMUM SHOWN INCLUDING AN ALLOWANCE FOR A SINGLE H-20 TRUCK WITH A 1.5 IMPACT FACTOR UNLESS NOTED. 5. RING DEFLECTION LIMITED TO 3%, MINIMUM SAFETY FACTOR OF 2. EARTH LOAD BASED ON SOIL WEIGHT OF 120 PCF. STANDARD DETAIL Metropolitan Sewerage District of Buncombe Count,, North Carolina TYPICAL TRENCH DETAIL FOR DUCTILE IRON PIPE - 1 DATE APPROVED: MARCH 2017 2.05-01 Maximum Depth of Cover for Ductile Iron Pipe w/ Cement Lining Pipe Size Class v7 Q STANDARD DETAIL U 0 O J Type 1 Type 2 Type 3 Type 4 Type 5 4 350 53 61 69 85 100 6 350 26 31 37 47 65 8 350 16 20 25 34 50 10 350 1 11 15 19 28 45 12 350 10 15 19 28 44 14 250 - 11 15 23 36 14 300 - 13 17 26 42 14 350 - 14 19 27 44 16 250 - 11 15 24 34 16 300 - 13 17 26 39 16 350 - 15 20 28 44 18 250 - 10 14 22 31 18 300 1 13 17 26 36 18 350 - 15 19 28 41 20 250 - 10 14 22 30 20 300 - 13 17 26 35 20 350 - 15 19 28 38 24 200 - 8 12 17 25 24 250 - 11 15 20 29 24 300 - 13 17 24 32 24 350 - 15 19 1 28 37 30 200 - 8 12 16 24 24 250 - 11 15 19 27 30 300 - 12 16 21 29 30 350 - 15 19 25 33 36 200 - 8 12 15 23 36 250 - 10 14 1 18 25 36 300- 12 16 20 28 36 350 - 15 19 24 32 42 200 - 8 12 15 22 42 250 - 10 14 17 25 42 300 - 12 16 20 27 42 350 - 15 19 1 23 32 48 200 - 8 11 15 22 48 250 - 10 13 17 24 48 300 - 12 15 19 27 48 350 - 15 18 22 30 54 200 - 8 11 14 22 54 250 - 10 13 16 24 54 300 - 13 15 1 19 27 54 350 - 15 18 22 30 60 200 - 8 11 14 22 60 250 - 10 13 16 24 60 300 - 13 15 19 26 60 350 - 15 18 22 30 64 200 - 8 11 14 21 64 250 - 10 13 16 24 64300 - 12 15 19 26 64 1 350 1 - 15 17 21 29 SOURCE: Ductile Iron Pipe for Wastewater Applications, DIPRA 2006 STANDARD DETAIL Metropolitan Sewerage District of Buncombe Count, North Carolina TYPICAL TRENCH DETAIL FOR DATEAPPRODVED� RILE 11RON PIPE - 2205-02 NOTES: NOTES: 1. WYE CONNECTIONS ARE STANDARD FOR NEW SEWER MAIN CONSTRUCTION. 1. WYE CONNECTIONS ARE STANDARD FOR NEW SEWER MAIN CONSTRUCTION. 2. FORCE MAINS CARRYING DOMESTIC WASTEWATER FROM SANITARY CONVENIENCES 2. FORCE MAINS CARRYING DOMESTIC WASTEWATER FROM SANITARY CONVENIENCES PROVIDED THAT GRAVITY FLOW WILL BE MAINTAINED DURING PROPOSED MAXIMUM WITHIN A SINGLE BUILDING, MAY CONNECTED TOA 4" MSD GRAVITY SERVICE LINE WITHIN A SINGLE BUILDING, MAY BE CONNECTED TO A 4" MSD GRAVITY SERVICE LINE DISCHARGE RATE FOR THE GRINDER OR EFFLUENT PUMP(S). PROVIDED THAT GRAVITY FLOW WILL BE MAINTAINED DURING PROPOSED MAXIMUM 3. WHERE COVER IS LESS THAN 3 FT. DUCTILE IRON MUST BE USED. DISCHARGE RATE FOR THE GRINDER OR EFFLUENT PUMP(S). 4. WHERE DUCTILE IRON IS REQUIRED RISER MAY BE CONSTRUCTED WITH SCH. 40 PVC 3. WHERE COVER IS LESS THAN 3 FT. DUCTILE IRON MUST BE USED. 4. WHERE DUCTILE IRON IS REQUIRED RISER MAY BE CONSTRUCTED WITH SCH. 40 PVC 2' MAX. UNLESS OTHERWISE INDICATED --i COUNTERSUNK PVC PLUG I COUNTERSUNK PVC PLUG LU Z_ 0 CLEANOUT BOX INSTALLED I J LU a ON 8" OF COMPACTED PIPE >-> m IN-LINE WYE (REQ'D FOREMBEDMENT MATERIALS a OU a LINES 12" AND LESS I 0 z< a- SCHED. 40 PVC or D.I.P. I Q (0 CLEANOUT BOX 1 FT. SECTION OF PIPE WITH GLUED CAP. ' INSTALLED ON 8" OF D COMPACTED PIPE BEND EMBEDMENT SEWER LATEL CONSTRUCTED AT 2% GRADE UNLESS OTHERWISE INDICATED. I MATERIALS UNDISTURBED EARTH PROVIDE STONE BEDDING UNDER WYE (OR TAPPING SADDLE) AND BEND CONNECT TO EXISTING SEWER SERVICE WITH APPROVED "COUPLING" OR INSTALL PVC PLUG FOR FUTURE SERVICE. WHEN REQUIRED BACKFLOW VALVES SHALL BE INSTALLED ON PORTION OF LATERAL TO BE MAINTAINED BY PROPERTY OWNER. - PVC REQUIRES 6" BEDDING FULL LENGTH OF SERVICE TRENCH SHALL BE COMPACTED IN 6" LIFTS STANDARD DETAIL Metropolitan Sewerage District of Buncombe County, North Carolina SANITARY SEWER SERVICE LESS THAN 5' DEEP DATE APPROVED: MARCH 2017 2.07-03 2' MAX. UNLESS OTHERWISE INDICATED I CONNECT TO EXISTING SEWER SERVICE WITH APPROVED COUPLING OR INSTALL PVC PLUG FOR FUTURE SERVICE. WHEN REQUIRED BACKFLOW VALVES SHALL BE INSTALLED ON PORTION OF LATERAL TO BE MAINTAINED BY PROPERTY OWNER. SEE DETAIL 2.07-03 FOR ADDITIONAL NOTES GLUED CAP NOTE CUT OFF EXTENSION TO CONNECT HOUSE SERVICE (PROVIDE MINIMUM COVER OF 30") AND INSTALL CLEAN-OUT 45° BEND STANDARD DETAIL Metropolitan Sewerage District of Buncombe County, North Carolina SANITARY SEWER SERVICE MORE THAN 5' DEEP DATE APPROVED: MARCH 2017 2.07-04 TRENCH WIDTH THE MINIMUM TRENCH WIDTH SHALL BE THE NOMINAL PIPE DIAMETER PLUS 24", EXCEPT THAT THE MINIMUM TRENCH WIDTH SHALL NOT BE LESS THAN 48" IN ANY CASE UNDISTURBED EARTH BACKFILL IN 12" LIFTS & COMPACT TO 92% STANDARD PROCTOR. BACKFILL IN 6" LIFTS & COMPACT TO 95% STANDARD WHEN IN PAVED AREAS OR ON ROADWAY SHOULDERS. PIPE EMBEDMENT MATERIAL TO SPRINGLINE INITIAL BACKFILL LIGHTLY COMPACTED TRENCH FOR PVC PIPE (15" DIA. AND LESS N.T.S. NOTES: 1. WALL THICKNESS SHALL BE SDR 35. 2. PVC PIPES REQUIRE #57 WASHED STONE PIPE EMBEDMENT MATERIALS. 3. THIS DETAIL IS VALID FOR PVC SEWER PIPE INSTALLED AT DEPTHS OF UP TO 20 FEET. 4. PVC PIPE NOT ALLOWED WITH LESS THAN 3'-0" COVER. 5. NO BOULDERS OR STONES WILL BE USED IN INITIAL BACKFILL. 6. WHEN TRENCH IS SUBJECT TO INUNDATION, EMBEDMENT MATERIALS MUST EXTEND TO TOP OF PIPE. TRENCH BACKFILL IN MSD RIGHTS OF WAY N.T.S. STANDARD DETAIL Metropolitan Sewerage District of Buncombe County, North Carolina TRENCH BACKFILL DATE APPROVED: MARCH 2017 1.16-01 U) O W VJ Z J Q J J W W 0 U U) SHEET C-506 �w011 v7 Q STANDARD DETAIL U 0 O J Z J Metropolitan Sewerage District U - - O of Buncombe County, North Carolina w V) W W TRENCH FOR PVC PIPE - OO U DATE APPROVED: MARCH 2017 2.04-01 W 0 M I --I r� VJ H � o I� N N N Z U) I.- Z 0_� o v1 QI � N U O UU U `'' i z � W � x EXISTING SOIL \\/�Y \' \%\\/\\/\\/\\/\\ //\//\///\//\//\//\//\ EXISTING SOIL w O w W W W 12" OF FINE LOOSE EARTH FREE \/\ FROM LARGE CLODS, STONES, Q C) 7 L DEBRIS, VEGETABLE MATTER, Irr-��I rn n \.J Q O + w TRENCH BACKFILL IN MSD RIGHTS OF WAY N.T.S. STANDARD DETAIL Metropolitan Sewerage District of Buncombe County, North Carolina TRENCH BACKFILL DATE APPROVED: MARCH 2017 1.16-01 U) O W VJ Z J Q J J W W 0 U U) SHEET C-506 U Q STANDARD DETAIL O J Z J Metropolitan Sewerage District - - O of Buncombe County, North Carolina V) L.L TRENCH FOR PVC PIPE - OO U DATE APPROVED: MARCH 2017 2.04-01 0 M VJ �= O Z U) I.- Z Ov �p O UU U `'' i z OQ p O w EXISTING SOIL \\/�Y \' \%\\/\\/\\/\\/\\ //\//\///\//\//\//\//\ EXISTING SOIL O LL Z W 12" OF FINE LOOSE EARTH FREE \/\ FROM LARGE CLODS, STONES, Q C) 7 L DEBRIS, VEGETABLE MATTER, n w OR OTHER OBJECTIONABLE MATERIALS. + DRY\ UNDISTURBED b TRENCH BACKFILL MATERIAL = EARTH iv COMPACTED TO 85% STANDARDo PROCTOR IN 12" LIFTS. < \� U) DID o o0 N z = W 00~ w W w U BACKFILL TRENCH DETAILS.INITIAL 0� Oz tjj z m z 2 0 2 Q 0 z o� mQ W Q W O W� J(6 °r° 0 0 0 O U IL d TRENCH BACKFILL IN MSD RIGHTS OF WAY N.T.S. STANDARD DETAIL Metropolitan Sewerage District of Buncombe County, North Carolina TRENCH BACKFILL DATE APPROVED: MARCH 2017 1.16-01 U) O W VJ Z J Q J J W W 0 U U) SHEET C-506 �w°� 0 U U 45' R /W w w 4' ® 4% 4' ® 4% �--, 13.5' 16' 29; MIN. SLOPE 2" S9.5C r 2% 2%-� O � J �••, 31 �.1 � vNj ISI N PROPOSED ELECTRICAL SERVICE TO BE PROVIDED BY DUKE ENERGY i.//../i /i /i\//\ N 7 6 8" ABC � x pia COMPACTED SUBGRADE PROPOSED 8" WATER LINE a • U PROPOSED 8" SEWER LINE Z PROPOSED STORMWATER PIPE a ST TYPICAL PRIVATE ROAD �W 8 CROSS-SECTION w NOT TO SCALE w44 W I --I rn \.J Q O W w� 30' R/W 2' 0 4% 2' ® 4% 0 � 13.5' 12' 29; MIN. SLOPE � 2% 2%- Al o a a ° u: ° T /lf\\/\/\/\/\/\/\//\//\//\//\//\//\//\� 8" CONCRETE PAD 7 J Z PROPOSED WATER LINE (1 MIN. COMPACTED ABC — J O (100% STANDARD) �O >O U ST TYPICAL SHARED DRIVEWAY 00 8 CROSS-SECTION m NOT TO SCALE V) Q I� (D= O Z U) >- U) U) Q Z Ov � �p O U(/) U C) Z OQ p 006 U) �p w QZ o z U)w 0) �Q �o CD N} Q w w ao z °° w w 0 IY 0Y 0 z m zF-: Q z L1J CD 0 LD U) z o 00 H (n D (n z J O p Q w Q w 0 00 3 0 D 0 0 0 li /1 Z) O Lu /) Z J Q w� U U) 2 SHEET C=511 NO. DATE BY REVISION DESCRIPTION