Subject: Compliance Evaluation Inspection
American Truetzschler
NPDES Permit NCO058928
Groundwater Remediation
Charlotte, Mecklenburg County
On June 25, 2019, staff from the Mooresville Regional Office (MRO) performed a compliance inspection
of the Groundwater Remediation system at the subject site to determine compliance with the permit.
Enclosed is a copy of the inspection report. Please see the MRO suggestions for maintenance in the
inspection report.
The system is online and performing at levels consistent with the permit for this facility. This permit
requires a PC-1 operator classification. Please be sure that all ORC information for this permit is current.
Should you have any questions with the site inspection report or the findings list herein, I may be reached
by phone at (704) 663-1699 or by email at edward.watson&ncdenr. og_v, should you have questions.
Sincerely,
DocuSigned by:
A wNNuft
F161 F669A2D84A3...
Andrew H. Pitner, P.G.
Assistant Regional Supervisor
Mooresville Regional Office
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ
Attachment: Compliance Inspection Report
CC: Mr. Mike Stanforth, Excel Civil & Environmental Associates (via email)
DWR Files (Laserfiche)
D Q
� North Carolina Department of Environmental Quality I Division of Water Resources
Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115
NOAn-icJwauNn i
nwm,em of eem—woviRv 704,663.1699
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN I 2 IF I 3 I NCO085928 111 12 I 19/06/25 I17 18 I S J 19 L G] 201 I
211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I f6
Inspection
Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved -------------------
67
1.0 70 I z I 71 I— „ I 72 I I 73 I I I 74 751
I —I I� I I I I I I I I80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES oermit Number)
09:42AM 19/06/25
15/11/01
Truetzschler remediation site
12300 Moores Chapel Rd
Exit Time/Date
Permit Expiration Date
Charlotte NC 28266
11:04AM 19/06/25
20/06/30
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Dirk Jaekel,PO Box 669228 Charlotte NC 28266//704-391-5340/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Records/Reports
Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Edward Watson MRO GW///
Signature of Management Q A Reviewer Docusigned by: Agency/Office/Phone and Fax Numbers Date
fi*uw N P44t
6.28.19
F161FB69A2D84A3...
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
NPDES yr/mo/day Inspection Type (Cont.)
NCO085928 I11 121 19/06/25 117 18 JCJ
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Staff from the MRO performed a Compliance Inspection for the American Truetzschler facility under
permit NC0085928. During the site visit, a facility review was performed. It may have been previously
mentioned that the paperwork for the system needed to be kept at the treatment system. However, the
paperwork and permit have become damaged. Please keep the paperwork in an office area where it
can be protected.
Laboratory data were reviewed during the site visit. Three years of data were present for review. The
data appears to be in order an complete.
The permit indicates that flow is through a UT to the Catawba River. Flow is actually through an
engineered ditch. Discharge flow from the treatment system never reaches the Catawba River.
The subject of the installation of a ditch or pipe to the Catawba River has been discussed in the past
with regards to reducing the Bio-monitoring percent passing requirement for this permit. A file review
does not indicate a resolution to the issue of pipe/trench installation has been established. The
installation of trench/pipe should display the 7Q10 flow for this system is not enough to reach the river
and discharge flow will eventually percolate into the soils.
Currently, the system has been able to attain the 90% pass requirement, so the permittee may also
choose to submit the permit renewal with no change rather than incur the expense of pipe or trench
installation. If you chose to submit the permit renewal with no change, the MRO will accept this as the
resolution of this issue.
The current permit is scheduled to expire in a year. Please be sure to submit the renewal application
at least 180 days prior to permit expiration.
Page#
Permit: NCO085928 Owner - Facility: Truetzschler remediation site
Inspection Date: 06/25/2019 Inspection Type: Compliance Evaluation
Permit
Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
❑
0
❑
❑
application?
Is the facility as described in the permit?
0
❑
❑
❑
# Are there any special conditions for the permit?
❑
0
❑
❑
Is access to the plant site restricted to the general public?
0
❑
❑
❑
Is the inspector granted access to all areas for inspection?
0
❑
❑
❑
Comment: During the inspection, the permit was reviewed with Mr. Gary Hames of American
Truetzschler. The various part of the permit were explained to Mr. Hames. MRO contact
information was also left with Mr. Hames in the event that he had any questions pertaining to
the permit.
I requested that the permit and supporting document be kept in Mr. Hames office for the
protection of the paperwork.
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: O&M records were Dresent. The records aDDeared to be current and complete for three
years.
The effluent meter appears to be relatively new. However, effluent flow meter calibration
records are not up-to-date.
Please perform an internal calibration of the meter and submit the calibration information by
email to the MRO.
The outfall displayed no foam, solids or odor being present. However, debris obstructing the
discharge flow -path prevented being able to follow the discharge channel. This area should
be kept assessible for purposes of being able to inspect flow.
Please submit a copy of the waste manifest for the spent Carbon. Samples for this system
are collected at the system outfall.
Page# 3