Loading...
HomeMy WebLinkAboutNCG140364_Ltr re Compliance Eval_20190617ROY COOPER NORTH CAROLINA Governor Environmental Quality MICHAEL S. REGAN ,Secretary WILLIAM E. (TOBY) V NSON,1R interim Director June 17, 2019 Thomas Concrete Of Carolina Inc. Attention: Earl Strickland 3701 N. Graham Street Charlotte, North Carolina 28206 Subject: Compliance Evaluation Inspection Thomas Concrete Of Carolina Inc. NPDES Stormwater Certificate of Coverage- NCG140364 Union County, North Carolina Dear Mr. Strickland: JUN 2 6 10B DENR-LAND QUALM( STORMA'ATER PERIV-IT"i INO Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection we conducted at the Thomas Concrete in Monroe on June 13, 2019. Please note that in the stormwater inspection report summary we ask that you correct the broken secondary containment valves. The report should be self-explanatory; however, should you have any questions, please do not hesitate to contact me at (704) 663-1699 or by E-mail at james.moore@ncdenr.gov. Enclosure c: Stormwater Permitting Branch Sincerely, Yes Moore Assistant Regional Engineer oep�»antot F:. re+mnaFabutr North Carolina Department of Environmental Quality 1 Division o€Energy. Mineral and Land Resources Mooresville Regional Office 1 610 East Center Avenue, Suite 301 i Mooresville, North Carolina 28115 Permit: NCG140364 SOC: County: Union Region: Mooresville Contact Person: Darrell Myers Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 06/13/2019 Primary Inspector: Lily C Kay Secondary Inspector(s): Compliance Inspection Report Effective:, 08/01/17 Expiration: 06/30/22 Owner: Thornas Concrete Of Carolina Inc Effective: Expiration: Facility: Thomas Concrete Broome St Title: Entry Time: 12:50PM Certification: Monroe NC 28110 Phone: 704-333-0390 Phone: Exit Time: 01 :15PM Phone: 704-663-1699 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Ready Mix Concrete Stormwater/Wastewater Discharge COC Facility Status: ❑ Compliant ® Not Compliant Question Areas: ® Storm Water (See attachment summary) Page 1 of 3 Permit: NCG140364 Owner Facility: Thomas Concrete Of Carolina Inc Inspection Date: 06/13/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: The facility appears to be well operated and maintained except for the broken secondary containment vavles. If you have any questions, please contact me at Lily. Kay@ncdenr.gov or by phone at (704) 235-2137. Page 2 of 3 Permit: NCG140364 Inspection Date: 06/13/2019 Owner -Facility: Thomas Concrete Of Carolina Inc Inspection Type :.Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Does the site have a Stormwater Pollution Prevention Plan? # Does the Plan include a General Location (USGS) map? # Does the Plan include a "Narrative Description of Practices"? # Does the Plan include a detailed site map including outfall locations and drainage areas? # Does the Plan include a list of significant spills occurring during the past 3 years? # Has the facility evaluated feasible alternatives to current practices? # Does the facility provide all necessary secondary containment? # Does the Plan include a BMP summary? # Does the Plan include a Spill Prevention and Response Plan (SPRP)? # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? # Does the facility provide and document Employee Training? # Does the Plan include a list of Responsible Party(s)? # Is the Plan reviewed and updated annually? # Does the Plan include a Stormwater Facility Inspection Program? Has the Stormwater Pollution Prevention Plan been implemented? Comment: The secondary containment release valves are broken and stormwaterwas being discharged without an inspection for sheen and color. These pre-release inspections must be documented and kept with the SWPPP. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ®❑ ❑ ❑ Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ® ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ®❑ ❑ ❑ Comment: Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ® ❑ ❑ ❑ # Were all outfalls observed during the inspection? ®❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ® ❑ ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ® ❑ ❑ ❑ Comment: The facility only has one outlet past the treatment and collection cells. Page 3 of 3