Loading...
HomeMy WebLinkAbout310363_Plan of Action_201811140 -10.4 901 SO 3�3 3l-- 3-63 PLAN OF ACTION(Poa) FOR HIGH FREEBOARD AT ANIMAL FACILITIES Facility Number: 31-363 Facility Name: Hwy. 41 Certified Operator Name: County: Duplin Joe Szaloky Operator Number: AWA999328 1. Current liquid levels) in inches as measured from the current liquid level in the lagoon to the lowest point on the top of the dam for lagoons without spillways; and from the current liquid level 'in the lagoon to the bottom)of the spillway for lagoons with spillways. Lagoon Name/ID: Spillway(Y or N): Level(inches): Lagoon 1 Lagoon 2 Lagoon 3 Lagoon 4 Lagoon 5 4118 4119 N N 18 33 2. Check all applicable items Liquid level is within the designed structural freeboard elevations of one or more structures. Five and 30 -day Plans of Action are attached. Hydraulic and agronomic balances are within acceptable ranges. X Liquid level is within the 25 year 24 hour storm elevations for one or more structures. A 30 day Plan of Action is attached. Agronomic balance is within acceptable range. Waste is to be pumped and hauled to off site locations. Bolume and PAN content of waste to be pumped and -hauled is reflected in section III tables. Included within this plan is a list of the proposed sites with related facility numbers, number of acres and receiving crop information.- Contact and secure approval from the DWQ prior to transfer of waste to a site not covered in the facility's CAWMP. Operation will be partially or fully depopulated. '`Attach a complefe schedule with corresponding animal units and dates fro depopulation `if animals are to be moved to,another permitted facility, provide facility number, lagoon freeboard levels and herd population for the receiving facility 3. Earliest possible date to begin land application of waste: as conditions permit I hereby certify that 1 have reviewed the information listed above and included within the attached Plan of Action, and to the best of my knowledge and ability, the information is :accurate and correct. Advantage Farms LLC Phone: (910)293-3434 Facility Owner/Manager (print) 0'P_ Date: 11 /14/2018 Facility Owner/Manager (sig ure) I. n II. TOTAL POUNDS OF PAN STORED WITHIN STRUCTURAL FREEBOARD AND/OR 25 YR./24 HR. STORM STORAGE ELEVATIONS IN ALL WASTE STRUCTURES FOR FACILITY 1. Structure ID: 4118 line m = 314.5 lb PAN 2. Structure ID: 4119 line m = lb PAN 3. Structure ID. line m = lb PAN 4. Structure ID. line m = lb PAN 5. Structure ID: line m = lb PAN 6. Structure ID: line m = lb PAN n.lines I+2+3+4+5+6= 1 314.5lbPAN III. TOTAL PAN BALANCE REMAINING FOR AVAILABLE CROPS DURING 30 DAY DRAW DOWN PERIOD. DO NOT LIST FIELDS TO WHICH PAN CANNOT eE APPLIFD DARING THIS 3n nAY PFRInn o tract # p. field # q. crop r. acres s. remaining IRR 2 PAN balance (lb/acre) t. TOTAL PAN BALANCE FOR FIELD (lbs.) column r x s u application window' 10 Wheat 4:13 117.00 483.2 Sept -April 11 Wheat 1.17 117.00 136.9 Sept -April 12 Wheat 1.65 117.00 193.1 Sept -April 14 Wheat 0.74 117.00 86.6 Sept -April 15 Wheat 1.28 117.00 149.8 Sept -April 21 Wheat 1.19 117.00 139.2 Sept -April State current crop ending application date or next crop application beginning"date for available receiving crops during 30 day draw down period. v. Total PAN available for all fields (sum of column t) = 1188 7 lb. PAN IV. FACILITY'S PoA OVERALL PAN BALANCE w. Total PAN to be land applied (line n from section II) = 314 5 lb. PAN PoA (30 Day) 2/21/00 x. Crop's remaining PAN balance (line v from section III) = 1188.7 lb. PAN y. Overall PAN balance (w - x) _ -874 lb. PAN Line y must show as a deficit. If line y does not show as a deficit, list course of action here including pump and haul, depopulation, herd reduction, etc. For pump & haul and herd reduction options, recalculate new PAN based on new information. If new fields are to be included as an option for lowering lagoon level, add these fields to the PAN balance table and recalculate the overall PAN balance. If animal waste is to be hauled to another permitted facility, provide information regarding the herd population and lagoon freeboard levels at the receiving facility. Irrigation onto, existing spray fields will continue as weather and field conditions permit. Additional land is available for pumping if needed. - Remaining PAN is an estimation. Grower did not provide remaining PAN or updated WA. PoA (30 Day) 2121/00 r+ PLAN OF ACTION (PoA) FOR HIGH FREEBOARD AT ANIMAL FACILITIES 30 DAY DRAW DOWN PERIOD I. TOTAL PAN TO BE LAND APPLIED PER WASTE STRUCTURE 1. Structure Name/Identifier (ID). 14118 2. Current liquid volume in 25 yr./24 hr. storm storage & structural freeboard a. current liquid level according to marker b. designed 25 yr./24 hr. storm & structural freeboard c. line b - line a (inches in red zone) = d. top of dike surface area according to design (area at below structural freeboard elevation) e. line c/12 x line d x 7.48 gallons/ft' 3. Projected volume of waste liquid produced during draw down period 18.0 inches 24.0 inches 6.0 inches 42300 ft2 158202 gallons f. temporary storage period according to structural design 180 days g. volume of waste produced according to structural design 39561 ft3 h. current herd # 1200 certified herd #1 1200 actual waste produced = current herd # x line g = 39561 ft3 certified herd # i. volume of wash water according to structural design j. excess rainfall over evaporation according to design k. (lines h + i +j) x 7.48 x 30. days/line f= 4 Total PAN to be land applied during draw down period I. current waste analysis dated 10/25/2018 m. ((lines e + k)/1000) x line I = REPEAT SECTION I FOR EACH WASTE STRUCTURE ON SITE. (Click on the next Structure tab shown below) PoA (30 Day) 2/21/00 0 ft3 24675 ft3 80081 gallons 1.32 Ibs/1000 gal. 314.5 Ibs. PAN w PLAN OF ACTION (PoA) FOR HIGH FREEBOARD AT ANIMAL FACILITIES 30 DAY DRAW DOWN PERIOD 1. TOTAL PAN TO BE LAND APPLIED PER WASTE STRUCTURE 1. Structure Name/Identifier (ID): 14119 2. Current liquid volume in 25 yr./24 hr. storm storage & structural freeboard a. current liquid level according to marker F 33.0 inches b. designed 25 yr./24 hr. storm & structural freeboard 19 0 inches c. line b - line a (inches in red zone) _ -14 inches d. top of dike surface area according to design (area at below structural freeboard elevation) 66000 ft2 e, line c/12 x line d x 7.48 gallons/ft'-575960 gallons 3. Projected volume of waste liquid produced during.draw down period f. temporary storage period according to structural design I 180 days g. volume of waste produced according to structural design 80705 ft3 h. current herd # 1 36481 certified herd # 3648 actual waste produced = current herd # x line g = 80705 ft' certified herd #- i. volume of wash water according to structural design j. excess rainfall over evaporation according to design k. (lines h + i + j) x 7.48 x 30 days/line f= 4. Total PAN to be land applied during draw down period I. current waste analysis dated 10/25/2018 m ((lines e + k)/1000) x line I = REPEAT SECTION I FOR EACH WASTE STRUCTURE ON SITE. (Click on the next Structure tab shown below) PoA (30 Day) 2/21/00 0 ft3 38500 ft3 148609 gallons , Ibs/1000 gal. 0 Ibs. PAN