Loading...
HomeMy WebLinkAboutWQ0040875_Application (FTSE)_20190620F -e-mi' VVQ0040875 , W - - , , Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dean.hunkele Coastal SWIRL& Permitted Flow YV Facility Name Harvest Meadows Subdivision Location Address ow n a r Owner marne City of Jacksonville Central Files. APS Status Project Type In review New Project Version Permit Classification A Individual Permit Contact Affiliation Majorltillinor Region Minor Wilmington 'County Onslow Facility Contact Afffliation Owner Type Government - Municipal Owner Affiliation Richard L. Woodruff P0 Box 128 Jacksonville NC 28541012 Scheduled Orig issue App Received Draft initiated Issuance Public Notice Issue Effective Expiration 5J 16/2019 Realuiatedl AcdvA�kes Requested' _!Rece;ved 'Events Additional information requested Additional information received SOUTH ENGINEERS SURVEYORS - PLANNERS ATk VIA EMAIL AND MAIL TO: Mr. Dean Hunkele NCDENR - DWR 127 Cardinal Dr. Ext. Wilmington, NC 28405-3845 Vt 21111F.-S, 141 01 F " I 1112 DATE: May 9,2019 REF: Harvest Meadows Sewer Improvements Fast Track Sewer Application One (1) original and One (1) copy of the Fast Track Application; One (1) Check in the amount of lmu�' - M-IMMMME-MON-01 01-MMEN-M-1 One (1) copy of the Sewer Plan Sheets 5 and 15 of 15. FIG 121WIVIRWAVIA 015 * Regular Mail 0 and 1:1 Federal Express * UPS Overnight 1:1 UPS Ground 11 Other nx For Approval 1:1 As Requested El For Your Use El For Bids Due 0 Other Copies To: 'A AnthoKy G. Moetezuma, Staff Engineer C1.2019,AGM.LOT,Hunkele.l-&O&tNt4oB,�MFg'*Sf4,PtO�(t8.l5. Box 976 1 Jacksonville, NC 28541-0976 1 (910) 455-2414 Firm License Number F-0108 I www.parkerjacksonville.com State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T.0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: "00 J i 5 (to be completed by DWR) 11_ 91 I'll i __ ININE119011 i ENS I I 1. Applicant's name: City of Jacksonville (company, municipality, HOA, utility, etc.) 1 Applicant type: El Individual El Corporation EJ General Partnership [I Federal E] State/County 0 Municipal 1 Signature authority's name: Ronald Massey per 15A NCAC 02-F Title: Deputy City manager 4. Applicant's mailing address: PO Box 128 City: Jacksonville State: NC Zip: 28541-0128 5. Applicant's contact information: Phone number: (210)938-5200 Email Address: citymanagerAjacksonvillenc.gov El Privately -Owned Public Utility El Other 2. Application/Project status: [] Proposed (New Permit) E] Existing Permit/Project If a modification, provide the existing permit number: WQOO and issued date: If new construction but part of a master plan, provide the existing permit number: WQOO 3. County where project is located: Onslow 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.80581' Longitude: -77.38114' 5. Parcel ID (if applicable): 033997 (or Parcel ID to closest downstream sewer) 1. Professional Engineer: Jason A. Houston License Number: 34978 Firm: Parker & Associates, Inc. Mailing address: 306 New Bridge Street City: Jacksonville State: NC Zip: 28540 — Phone number: (910) 455-2414 Email Address: office(a—),i)arkeriacksonville.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: City of Jacksonville Land Treatment System Permit Ntunber:.0009267 Owner Name: City of Jacksonville V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ0036173 Downstream (Receiving) Sewer Size: 8 inch 5yi,t_erqWLi2d_,-, �oklec_liq":Ls WQCS-- Owner Name(s): City of Jacksonville FORM: FTA 04-16 Page 1 of 5 I . If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? D Yes ]No SN/A 2. If the Applicant is a Developer of lots to be sold, has aD,". been attached? 3. If the Applicant is a _ I- %"�' been attached? '-Z"­ -, " ' ' 4. Origin of wastewater: (check all that apply): 0 Residential Owned F-1 Retail (stores, centers, malls) El Car Wash F-1 Residential Leased El Retail with food preparation/service El Hotel and/or Motels El School / preschool / day care EJ Medical / dental / veterinary facilities El Swimming Pool /Clubhouse El Food and drink facilities El Church El Swimming Pool/Filter Backwash El Businesses / offices / factories [] Nursing Home El Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial % Industrial ( L------>Is there a Pretreatment Program in effect? � Yes n No 6. Hasa flow reduction been approved under 0 Yes D No > If ves. Drovide a Copy of flow reductiqn_gggr2X&L1g1Le1 7. Summarize wastewater generated by project: Establishment Type (see Daily Design Flow ,b No. of Units Flow Dwelling Unit 360 gal/lot 95 34200 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 34200 GPD a See for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in b Per 15A NCAC 02T .0 1 14(c), design flow rates for establishments not identified [in table shall be determined. using available flow data, water using fixtures, occupancy or operation patterns, and other measured data, 8. Wastewater generated by project: 34200 GPD (per JDA Nk"" AQ,02 I Fffl 1- > Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: F] Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line El Rehabilitation or replacement of existing sewer with no new flow expected El Other (Explain): FORM: FTA 04-16 Page 2 of 5 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 4,560 PVC > Section 11 & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) > Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC 1, Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: 0 Longitude: - 0 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): - gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(13), Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: Ej Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T ,0305(h)(1)(C) 5N El Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(I)(Q: It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 Ix. SETBACKS & SEPARATIONS — (0213.0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in > 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Se aration Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet "Any private or public water supply source, including any wells, WS-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet * *Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet To slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches > C contains alternatives where separations in "'O"J" cannot be achieved. "Stream classifications can be identified using the Division's > If noncompliance with .a see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) OYes EJNo EIN/A > See the Division's draft separation requirements for situations where separation cannot be meet � No variance is required if the alternative design criteria specified is utilized in design and construction > As built documents should reference the location of areas effected � "I - —] 3. Does the project comply with setbacks found. in the river basin rules per ---E Yes E]No ®NIA ---- -------- c, > This would include Trout Buffered Streams per 4. Does the project require coverage/authorization under a 404 Nationwide or 0 Yes El No individual permits or 401 Water Quality Certifications? > Information can be obtained. from the Af,­ Per directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. D Yes El No E N/A > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 'Ahe andthe as applicable? FMM If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting docu e for review. the Fast Track A olication and s 4-0cumen1s. JASON A. HOUSTON attest that this application for (Professional Engineer's name from Application Item 111. 1 ....... ............... material and have judged it to be consistent with the proposed design. M LIM N —4 5,316 - Yy S SEAL 34970 -A %w that this application for injunctive elief, and/or criminal prosecution. I will make no claim against the Division of Water Resources uld a condition of this iermit bi violated, alic, W an d me as incomplete. Signature: Date: FORM FTA 04-16 Page 5 of 5 State of North Carolina Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10- 18) Entity Requesting Allocation: South State Development, LL.0 Project Name for which flow is being requested: Harvest Meadows More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. 11. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. Pump Pump Station Station Firm (Name or Permit Capacity, Number) No. MGD Country WQ 0028541 .324 Commons 15153 .360 (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Average Approx. Obligated, Total Daily Current Not Yet Current Flow Flow" Avg. Daily Tributary Plus (Firm / pf), Flow, Daily Flow, Obligated Available MGD MGD MGD Flow Capacity*** .129 .0025 .0345 .037 .092 .144 .0743 0 .0743 .0697 Henderson Unknown 7.44 2.976 1.010 .0675 1.077 1.899 Main Unknown 30 12 5.942 .0053 5.947 6.053 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. Downstream Facility Name (Sewer): Countryview Downstream Permit Number: WQ0028541 111. Certification Statement: I - Ronald F. Massey certify to the best of my knowledge that the addition of the volume of wastewater to be I%ermitte in this has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and 11 plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. N Tide of Agning Official o ` 340482M"N 77022'52A "W 5/1.7/201 9