Loading...
HomeMy WebLinkAboutNC0023604_Fact Sheet (revised)_20190618DEQ/DWR/NPDES FACT SHEET FOR NPDES PERMIT RENEWAL NPDES Permit NCO023604 Table 1-- Facility Information Applicant / Facility Name: Ronnie D. Bolt / Wilderness NC, Inc. Lumber Plant Applicant Address: P.O. Box 2136 Lexington 27293 Facility Address: 7578 US Hwy 64 E., Thomasville, NC 27360 Permitted Flow / Average: 0.0124 MGD Outfall 001 ; Outfall 002 not limited Type of Waste: SIC Codes 321912 & 32113 [principal process Kiln -drying lumber] Facility / Permit Status: Minor Industry, Class WW-2 / renewal County: Davidson Permit Special Conditions: Biocide Condition; eDMR required; High Rock Lake Re -Opener Miscellaneous Receiving Stream: UT to Flat Swamp Creek Regional Office: Winston-Salem Stream Class / Segment: C / 12-123 State Grid / USGS Quad: D18SE / Fair Grove 303 d Listed? No Permit Writer: Joe R. Corporon PG HUC: 03040101 Date: 18Jun2019 Drainage Area (mi2): 0.0 Lat. 350 46' 30" N Long. 800 07' 12" W Summer 7Q 10 (cfs) 0.0 Winter 7 10 cfs 0.0 Average Flow cfs : 0.0 IWC (%): Assume 100% Facility Summary: Wilderness NC, Inc. (Wilderness) produces kiln -dried lumber. Freshly milled lumber is delivered to their facility from offsite sources. Wilderness employees generate 100% domestic wastewater treated onsite by a Class WW-2 plant discharging via Outfall 001 and kiln condensate from the lumber -drying process via Outfall 002. These both discharge to a UT to Flat Swamp Creek. WWTP facilities include: • aeration chamber • sludge holding tank • clarifier • recirculating sand filter • 5:1 flow splitter • 1,500-gallon recirculation tank with air diffuser • filter screens • dual (2) pumps • tablet chlorination and dechlorination • polishing / settling pond (54-day retention) Receiving Stream: This facility discharges to a UT to Flat Swamp Creek, a Class C waterbody within the Yadkin -Pee Dee River Basin. This creek supports designated uses; not impaired — not listed on the 2018 NC 303(d) list. Compliance History & DMR Data Review - Jun2016 thru Jun2019: March and October of 2016 showed frequency violations for Temperature (no action — amended DMR). WSRO (Paul DiMatteo) proceeded to NOD for Fecal Coliform violation in Nov2017. BIMS notes multiple TRC violations, ignored per TRC policy as < 50 ug/L. WSRO (Paul DiMatteo) notes missing Fact Sheet NPDES NC0006548 Permit Renewal Jun2019 Page 1 Outfall 002 monitoring (semiannually) explained as calc error due to sample timing, as documented by ORC. Table 2 -Parameters of Concern (POCs) Compliance Summary - Jan2016-Jun2019 Parameter Units Averages Maximum Minimum Limit Exceedance / Count Temperature Ef °C 16.2 27 4 No / 874 Temperature U °C 14.5 25 < 2 - / 177 Temperature (D) °C 14.4 25 < 2 - / 178 Dissolved 02 Ef m /L 8.5 11.5 6.3 No / 177 Dissolved 02 m /L 4.9 11.3 < 1 - / 178 Dissolved 02 D m /L 5.0 11.6 <1 - / 177 Chlorine TRC L 22.7 50 4.7 No / 362 BOD-5 summer in /L 2.02 5 0.1 No / 100 BOD-5 winter in /L 2.04 3.19 < 2 No / 77 Ammonia (summer) in /L 0.15 5 0.01 No / 101 Ammonia (winter) m /L 0.16 1.63 0.1 No / 77 Solids (TSS) 5.1 19.8 <5 No / 178 Fecal Coliform n / 100 nil 16.5 2,420 < 1 2 / 178 TN m /L 2.5 4.78 < 1 No / 14 TP m /L 1 0.94 1 1.26 1 0.45 1 No / 14 Flow MGD 1 0.0007 1 0.0012 1 0.0001 1 No / 185 WET -Testing and Instream Monitoring: This permit requires instream monitoring for Temperature and Dissolved Oxygen upstream and downstream. Data is consistently similar at both monitoring stations, and within water -quality standards. This permit does not require Whole Effluent Toxicity (WET) testing - no permit changes recommended. Renewal Change Summary: The Permittee has made no changes in processes or WWTP facilities since last renewal. Monitoring and sampling include BOD-5 and Ammonia (summer / winter limits consistent with similar Class -2 WWTPs) plus effluent and instream monitoring for Dissolved Oxygen and Temperature. According to the renewal application, production volumes for kiln drying are identical to those presented for the previous permit cycle - no permit changes recommended. Proposed Schedule for Issuance: Draft Permit to Public Notice: June 26, 2019 Tentative Scheduled to Issue: August 9, 2019 NPDES Contact: If you have questions regarding the above information or the attached permit, please contact Joe R. Corporon P.G. Uoe.corporon@ncdenr.gov] or call his direct line 919-707-3617. NAME: DATE: Fact Sheet NPDES NC0006548 Permit Renewal Jun2019 Page 2 Joe Corporon NOTE: data (hidden here) indicate limit exceedences for lance COril lance Comp 18Jun2O19 TRC (< 50 ug/L) --not Jan2016-Jun2019 considered violations under current TRC policy. PERMIT FACILITY MONTH YEAR OUTFALL PARAMETER VIOL DATE UNITS LIMIT CALC VAL % OVER VIOL TYPE VIOL ACTION VIOL COMMENT UPDATED BY NC0023604 Wilderness -NC Lumber Plant 3 2016 001 Temperature, Water Deg. 03/05/2016 deg c Frequency Violation No Action, BPJ april.norton Centigrade NC0023604 Wilderness -NC Lumber Plant 10 2016 001 Temperature, Water Deg. 10/01/2016 deg c Frequency Violation No Action, Facility Rep, will submit an amended DMR april.norton Centigrade NC0023604 Wilderness -NC Lumber Plant 11 2017 001 Coliform, Fecal MF, MFC Broth, 11/29/2017 #/100ml 400 2420 505 Daily Maximum Proceed to NOD paul.dimatteo 44.5 C Exceeded NC0023604 Wilderness -NC Lumber Plant 1 2019 002 03/03/2019 Outfall Missing None bimsprod.cron NC0023604 Wilderness -NC Lumber Plant 3 2019 002 05/01/2019 Outfall Missing None bimsprod.cron No Action, BIMS 10/30/2018 PMD I spoke with the Calculation Error ORC, semiannual monitoring for NC0023604 Wilderness -NC Lumber Plant 7 2018 002 08/31/2018 Outfall Missing this outfall was conducted in April paul.dimatteo and will be done again this week. No Action, Facility 12/14/18 PMD - semiannual NC0023604 Wilderness -NC Lumber Plant 9 2018 002 10/31/2018 Outfall Missing Reporting Error monitoring @ outfall 002 paul.dimatteo conducted in 10/18 NC0023604 Wilderness -NC Lumber Plant 1 11 1 2018 1 002 1 1 12/31/2018 1 1 1 1 1 Outfall Missing None I lbims rod.cron