Loading...
HomeMy WebLinkAboutWQCS00084_Compliance Evaluation Inspection_20190621ROY COOPER covemor MICHAEL & R.EGAN Secretary LINDA CULPEPPER Diwtor James Fatland City of Brevard 95 West Main Street Brevard, NC 28712 NORTH CAROL INA Environmental Quality June 21, 2019 SUBJECT: Compliance Inspection Report Brevard Collection System Collection System Permit No. WQCS00084 Transylvania County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Brevard Collection System on 6/13/2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Collection System Permit No. WQCS00084. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant non -compliant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. The following items were noted: Brevard has both the authority and responsibility to enforce the Sewer Use Ordinance against problem users to maintain the collection system. During a previous meeting, the Sapphire Manner collection system upgrade project was discussed. A status update to this project is requested by ARO. N"NCarokisDepartment ofEnvironmental Quality I OivisionofWater Resources Ashevil ie Regional Office 12090 U.S_ 70 if imay I Sw nanoa, North CaroLaa 23773 Q 32S 29C-0800 If you should have any questions, please do not hesitate to contact Timothy Heim with the Water Quality Regional Operations Section in the Asheville Regional Office at 828-296-4500 or via email at tim.heim@ncdenr.gov. Sincerely, DocuSigned by: 1105A3C fi 6 f t6m 082BA418... For G. Landon Davidson, P.G., Regional Supervisor Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Ec: WQS-ARO Server LF G:\WR\WQ\Transylvania\Collection Systems\Brevard Collection System WQCS00084\Inspections\2019\20190621_WQCS00084_CEI Ltr.Docx North CarokkaDepartmentofEnvironmental Quality I OivisionofWater Resources Asheville Regional Office 2090 U.8_70M giyway I Swan nanos. No rth Carolaa 23773 Q 32S 29C-0800 Permit: WQCS00084 SOC: County: Transylvania Region: Asheville Compliance Inspection Report Effective: 04/01/16 Expiration: 03/31/24 owner: City of Brevard Effective: Expiration: Facility: Brevard Collection System 151 W Main St Contact Person: Jeffrey T Brown Directions to Facility: System Classifications: CS2, Primary ORC: Secondary ORC(s): Nathaniel Wayne Littleton William A Dodson David Stuart Lutz On -Site Representative(s): Title: Consultant Certification: 1001980 1002009 25713 24 hour contact name David Lutz Related Permits: NC0060534 City of Brevard - Brevard WWTP Inspection Date: 06/13/2019 Entry Time: 09:30AM DS Primary Inspector: Timothy H Heim rya Secondary Inspector(s): Brevard NC 28712 Phone: 828-350-7683 Phone: 828-884-2171 828-884-2171 828-883-8461 Exit Time: 12:OOPM Phone: 828-296-4665 Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation Facility Status: Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions Performance Standards Operation & Maint Reqmts Pump Station (See attachment summary) Page 1 of 8 Permit: WQCS00084 Owner - Facility: City of Brevard Inspection Date: 06/13/2019 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: Tim Heim of the Asheville Regional Office performed a routine Compliance Evaluation Inspection of the collection system on June 13, 2019. David Lutz, Nathaniel Littleton, Letha Cox and June Stewart assisted with the records review and inspection. Records were meticulously organized and maintained, and the collections system appeared compliant at the time of the inspection. The following items were noted: The collection system continues to experience significant I&I during rain events, however much progress has been made with recent infrastructure improvements and the Utility Director reports that considerable additional progress is anticipated as they pursue the findings of the CDM Flow Study. The previous thermal/infrared aerial study was very productive in helping identify I&I defects, the city is considering conducting a follow up study. Brevard has both the authority and responsibility to enforce the Sewer Use Ordinance against problem users to maintain the collection system. During a previous meeting, the Sapphire Manner collection system upgrade project was discussed. A status update to this project is requested by ARO. Page 2 of 8 Permit: WQCS00084 Owner - Facility: City of Brevard Inspection Date: 06/13/2019 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Performance Standards Yes No NA NE Is Public Education Program for grease established and documented? 0 ❑ ❑ ❑ What educational tools are used? FOG handouts are distributed with the water bills, the city is considering including FOG educational material on the its website. Is Sewer Use Ordinance/Legal Authority available? ❑ ❑ ❑ Does it appear that the Sewer Use Ordinance is enforced? ❑ ❑ ❑ Is Grease Trap Ordinance available? ❑ ❑ ❑ Is Septic Tank Ordinance available (as applicable, i.e. annexation) ❑ ❑ ❑ List enforcement actions by permittee, if any, in the last 12 months NA, however Brevard has both the authority and responsibility to enforce the Sewer Use Ordinance against problem users. Has an acceptable Capital Improvement Plan (CIP) been implemented? ❑ ❑ ❑ Does CIP address short term needs and long term \"master plan\" concepts? ❑ ❑ ❑ Does CIP cover three to five year period? ❑ ❑ ❑ Does CIP include Goal Statement? ❑ ❑ ❑ Does CIP include description of project area? ❑ ❑ ❑ Does CIP include description of existing facilities? ❑ ❑ ❑ Does CIP include known deficiencies? ❑ ❑ ❑ Does CIP include forecasted future needs? ❑ ❑ ❑ Is CIP designated only for wastewater collection and treatment? ❑ ❑ ❑ Approximate capital improvement budget for collection system? $1,040,000.00 Total annual revenue for wastewater collection and treatment? CIP Comments Total CIP Budget $11.9M Is system free of known points of bypass? ❑ ❑ ❑ If no, describe type of bypass and location Is a 24-hour notification sign posted at ALL pump stations? ❑ ❑ ❑ # Does the sign include: Instructions for notification? ❑ ❑ ❑ Pump station identifier? ❑ ❑ ❑ 24-hour contact numbers ❑ ❑ ❑ If no, list deficient pump stations NA # Do ALL pump stations have an "auto polling" feature/SCADA? ❑ ❑ ❑ Number of pump stations 16 Number of pump stations that have SCADA 3 Page 3 of 8 Permit: WQCS00084 Owner - Facility: City of Brevard Inspection Date: 06/13/2019 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Number of pump stations that have simple telemetry 0 Number of pump stations that have only audible and visual alarms 13 Number of pump stations that do not meet permit requirements 0 # Does the permittee have a root control program? ❑ 0 ❑ ❑ # If yes, date implemented? Describe: The ORCs report that they do not experience problems with roots and do not require a root control program. Comment: Operation & Maintenance Requirements Yes No NA NE Are all log books available? ❑ ❑ ❑ Does supervisor review all log books on a regular basis? ❑ ❑ ❑ Does the supervisor have plans to address documented short-term problem areas? ❑ ❑ ❑ What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas? Work orders are recorded daily and reviewed by the supervisor, then entered into a master spreadsheet. Problem areas are reviewed as necessary. Are maintenance records for equipment available? ❑ ❑ ❑ Is a schedule maintained for testing emergency/standby equipment? ❑ ❑ ❑ What is the schedule for testing emergency/standby equipment? Weekly Do pump station logs include: Inside and outside cleaning and debris removal? 0 ❑ ❑ ❑ Inspecting and exercising all valves? 0 ❑ ❑ ❑ Inspecting and lubricating pumps and other equipment? 0 ❑ ❑ ❑ Inspecting alarms, telemetry and auxiliary equipment? 0 ❑ ❑ ❑ Is there at least one spare pump for each pump station w/o pump reliability? 0 ❑ ❑ ❑ Are maintenance records for right-of-ways available? 0 ❑ ❑ ❑ Are right-of-ways currently accessible in the event of an emergency? 0 ❑ ❑ ❑ Are system cleaning records available? 0 ❑ ❑ ❑ Has at least 10% of system been cleaned annually? 0 ❑ ❑ ❑ What areas are scheduled for cleaning in the next 12 months? The system is cleaned in sequence by basin and as needed for problem areas. Is a Spill Response Action Plan available? 0 ❑ ❑ ❑ Does the plan include 24-hour contact numbers ❑ ❑ ❑ Response time ❑ ❑ ❑ Equipment list and spare parts inventory ❑ ❑ ❑ Access to cleaning equipment ❑ ❑ ❑ Access to construction crews, contractors, and/or engineers ❑ ❑ ❑ Source of emergency funds ❑ ❑ ❑ Page 4 of 8 Permit: WQCS00084 Owner - Facility: City of Brevard Inspection Date: 06/13/2019 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Site sanitation and cleanup materials 0 ❑ ❑ ❑ Post-overflow/spill assessment 0 ❑ ❑ ❑ Is a Spill Response Action Plan available for all personnel? 0 ❑ ❑ ❑ Is the spare parts inventory adequate? 0 ❑ ❑ ❑ Comment: GALLIMORE ROAD - Pump Station Yes No NA NE Pump station type Duplex Are pump station logs available? ❑ ❑ ❑ Is it accessible in all weather conditions? ❑ ❑ ❑ # Is general housekeeping acceptable? ❑ ❑ ❑ Are all pumps present? ❑ ❑ ❑ Are all pumps operable? ❑ ❑ ❑ Are wet wells free of excessive debris? ❑ ❑ ❑ Are upstream manholes free of excessive debris/signs of overflow? ❑ ❑ ❑ Are floats/controls for pumps/alarms operable? ❑ ❑ ❑ Is "auto polling" feature/SCADA present? ❑ ❑ ❑ Is "auto polling" feature/SCADA operational? ❑ ❑ ❑ Is simple telemetry present? ❑ ❑ ❑ Is simple telemetry operational? ❑ ❑ ❑ Are audio and visual alarms present? ❑ ❑ ❑ Are audio and visual alarms operable? ❑ ❑ ❑ Is the Pump station inspected as required? ❑ ❑ ❑ Are backflow devices in place? ❑ ❑ ❑ Are backflow devices operable? ❑ ❑ ❑ Are air relief valves in place? ❑ ❑ ❑ Are air relief valves operable? ❑ ❑ ❑ # Is an emergency generator available? ❑ ❑ ❑ Can the emergency generator run the pumps? ❑ ❑ ❑ Is the pump station equipped for quick hook-up? ❑ ❑ ❑ Is the generator operable? ❑ ❑ ❑ # Is fuel in tank and sufficient? ❑ ❑ ❑ Is the generator inspected according to their schedule? ❑ ❑ ❑ Is a 24-hour notification sign posted? 0 ❑ ❑ ❑ Does it include: Instructions for notification? 0 ❑ ❑ ❑ Page 5 of 8 Permit: WQCS00084 Owner - Facility: City of Brevard Inspection Date: 06/13/2019 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Pump station identifier? 0 ❑ ❑ ❑ Emergency phone number 0 ❑ ❑ ❑ Is public access limited? 0 ❑ ❑ ❑ Is pump station free of overflow piping? 0 ❑ ❑ ❑ Is the pump station free of signs of overflow? 0 ❑ ❑ ❑ Are run times comparable for multiple pumps? Comment: WILSON ROAD - Pump Station Yes No NA NE Pump station type Duplex Are pump station logs available? 0 ❑ ❑ ❑ Is it accessible in all weather conditions? 0 ❑ ❑ ❑ # Is general housekeeping acceptable? 0 ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? 0 ❑ ❑ ❑ Are wet wells free of excessive debris? ❑ ❑ ❑ Are upstream manholes free of excessive debris/signs of overflow? ❑ ❑ ❑ Are floats/controls for pumps/alarms operable? ❑ ❑ ❑ Is "auto polling" feature/SCADA present? ❑ ❑ ❑ Is "auto polling" feature/SCADA operational? ❑ ❑ ❑ Is simple telemetry present? ❑ ❑ ❑ Is simple telemetry operational? ❑ ❑ ❑ Are audio and visual alarms present? ❑ ❑ ❑ Are audio and visual alarms operable? ❑ ❑ ❑ Is the Pump station inspected as required? ❑ ❑ ❑ Are backflow devices in place? ❑ ❑ ❑ Are backflow devices operable? ❑ ❑ ❑ Are air relief valves in place? ❑ ❑ ❑ Are air relief valves operable? ❑ ❑ ❑ # Is an emergency generator available? ❑ ❑ ❑ Can the emergency generator run the pumps? ❑ ❑ ❑ Is the pump station equipped for quick hook-up? ❑ ❑ ❑ Is the generator operable? ❑ ❑ ❑ # Is fuel in tank and sufficient? ❑ ❑ ❑ Is the generator inspected according to their schedule? ❑ ❑ ❑ Is a 24-hour notification sign posted? ❑ ❑ ❑ Page 6 of 8 Permit: WQCS00084 Inspection Date: 06/13/2019 Owner - Facility: City of Brevard Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Does it include: Instructions for notification? 0 ❑ ❑ ❑ Pump station identifier? 0 ❑ ❑ ❑ Emergency phone number ❑ ❑ ❑ Is public access limited? ❑ ❑ ❑ Is pump station free of overflow piping? ❑ ❑ ❑ Is the pump station free of signs of overflow? ❑ ❑ ❑ Are run times comparable for multiple pumps? Comment: NEELY ROAD - Pump Station Yes No NA NE Pump station type Duplex Are pump station logs available? ❑ ❑ ❑ Is it accessible in all weather conditions? ❑ ❑ ❑ # Is general housekeeping acceptable? ❑ ❑ ❑ Are all pumps present? ❑ ❑ ❑ Are all pumps operable? ❑ ❑ ❑ Are wet wells free of excessive debris? ❑ ❑ ❑ Are upstream manholes free of excessive debris/signs of overflow? ❑ ❑ ❑ Are floats/controls for pumps/alarms operable? ❑ ❑ ❑ Is "auto polling" feature/SCADA present? ❑ ❑ ❑ Is "auto polling" feature/SCADA operational? ❑ ❑ ❑ Is simple telemetry present? ❑ ❑ ❑ Is simple telemetry operational? ❑ ❑ ❑ Are audio and visual alarms present? ❑ ❑ ❑ Are audio and visual alarms operable? ❑ ❑ ❑ Is the Pump station inspected as required? ❑ ❑ ❑ Are backflow devices in place? ❑ ❑ ❑ Are backflow devices operable? ❑ ❑ ❑ Are air relief valves in place? ❑ ❑ ❑ Are air relief valves operable? ❑ ❑ ❑ # Is an emergency generator available? ❑ ❑ ❑ Can the emergency generator run the pumps? ❑ ❑ ❑ Is the pump station equipped for quick hook-up? ❑ ❑ ❑ Is the generator operable? ❑ ❑ ❑ # Is fuel in tank and sufficient? ❑ ❑ ❑ Page 7 of 8 Permit: WQCS00084 Owner - Facility: City of Brevard Inspection Date: 06/13/2019 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Is the generator inspected according to their schedule? Is a 24-hour notification sign posted? Does it include: Instructions for notification? Pump station identifier? Emergency phone number Is public access limited? Is pump station free of overflow piping? Is the pump station free of signs of overflow? Are run times comparable for multiple pumps? Comment: • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 8 of 8