Loading...
HomeMy WebLinkAboutSW6190602_Engineering Calculations (Volume Needed)_20190619Dsite Edgerton Industrial Park Pond #1 Required Storm Volume slutions *civi�lengineering I land surveying Wet Pond Drainage Area: 17.1 acres Impervious Area: 559077 sf (12.83 ac) % Impervious: 75% 1 inch Storm Event: Rv = 0.05+0.009 1 Rv = runoff coefficient 1= percent impervious Rv=0.05+0.009*75% = 0.725 For volume that must be controlled: Volume=3,630*Rd*Rv*A Volume = 3,630*(1 inch)*(0.725)*17.1 acres = 45,003 cf SA/DA ratio is 2.72 for a depth of 3 feet Required surface area = 17.1 ac * (0.0272) = 0.465 ac or 20,261 sf Surface area provided = 32,615 sf 409 Chicago Drive, Suite 112, Fayetteville, NC 28306 office 1 910-426-6777 fax 1 910-426-5777 license number I C-2354 On time, every time. I www.4Dsitesolutions.com