Loading...
HomeMy WebLinkAboutNC0023604_Fact Sheet_20190613DEQ/DWR/NPDES FACT SHEET FOR NPDES PERMIT RENEWAL NPDES Permit NCO023604 Table 1-- Facility Information Applicant / Facility Name: Ronnie D. Bolt / Wilderness NC, Inc. Lumber Plant Applicant Address: P.O. Box 2136 Lexington 27293 Facility Address: 7578 US Hwy 64 E., Thomasville, NC 27360 Permitted Flow / Average: 0.0124 MGD Outfall 001 ; Outfall 002 not limited Type of Waste: SIC Codes 321912 & 32113 [principal process Kiln-dt-yim lumber Facility° / Permit Status: Minor Industrv, Class WW-2 / renewal County: Davidson Permit Special Conditions: Biocide Condition; eDMR required; High Rock Lake Re -Opener Miscellaneous Receiving Stream: UT to Flat Swamp Creek Regional Office: Winston-Salem Stream Class / Segment: C / 12-123 State Grid / USGS Quad: D18SE / Fair Grove 303(d) Listed? No Permit Writer: Joe R. Corporon PG HUC: 03040101 1 Date: I 13Jun2019 Drainage Area (mil): 0.0 Lat. 35° 46' 30" N Long. 80° 07' 12" W Summer 7Q 10 (cfs) 0.0 Winter 7Q 10 cfs) 0.0 Average Flow cfs . 0.0 IWC (%): Assume 100% FaKjpq Summary: Wilderness NC, Inc. (Wilderness) produces kiln -dried lumber. Freshly milled lumber is delivered to their facility from offsite sources. Wilderness employees generate 100% domestic wastewater treated onsite by a Class WW-2 plant discharging via Outfall 001 to a UT to Flat Swamp Creek. Outfall 002 discharges a kiln drying concentrate. WWTP facilities include: • aeration chamber • sludge holding tank • clarifier recirculating sand filter • 5:1 flow splitter 1,500-gallon recirculation tank with air diffuser • filter screens • dual (2) pumps • tablet chlorination and dechlorination • polishing / settling pond (54-day retention) Receiving Stream: This facility discharges to a UT to Flat Swamp Creek, a Class C waterbody within the Yadkin -Pee Dee River Basin. This creek supports designated uses; not impaired — not listed on the 2018 NC 303(d) list. Compliance History & DMR Data Review - Jun2016 thru Jun2019: March and October of 2016 showed frequency violations for Temperature (no action — amended DMR). WSRO (Paul DiMatteo) proceeded to NOD for Fecal Coliform violation in Nov2017. BIMS notes multiple TRC violations, ignored per TRC policy as < 50 ug/L. WSRO (Paul DiMatteo) notes missing Fact Sheet NPDES NC0006548 Pennit Renewal Jun2019 Page 1 Outfall 002 monitoring (semiannually) explained as calc error due to sample timing, as documented by ORC. Table 2 -Parameters of Concern (POCs) Compliance Summary - Jan2016-Jun2019 Parameter Units Averages Maximum Minimum Limit Exceedance / Count Temperature (EED °C 16.2 27 4 No / 874 Temperature C] °C 14.5 25 2 - / 177 Temperature D °C 14.4 25 2 - / 178 Dissolved OZ E m =. L 8.5 11.5 6.3 No / 177 Dissolved Oz U m /L 4.9 11.3 1 - / 178 Dissolved 02 D m L 5.0 11.6 1 - / 177 Chlorine TRC 1 22.7 50 4.7 No / 362 BOD-5 (summer) m L 2.02 5 0.1 • No / 100 BOD-5 winter m 2.04 3.19 2 No / 77 Ammonia summer) m L 0.15 5 0.01 No / 101 Ammonia winter mi 0.16 1.63 0.1 No / 77 Solids (TSS) m /L 5.1 19.8 <5 No / 178 Fecal Coliform n / 100 ml 16.5 2,420 1 2 / 178 TN m L 2.5 4.78 < 1 No / 14 TP m 0.94 1.26 0.45 No / 14 Flow MGD 1 0.0007 0.0012 0.0001 No / 185 WET-Testina and Instream Monitorina: This permit requires instream monitoring for Temperature and Dissolved Oxygen upstream and downstream. Data is consistently similar at both monitoring stations, and within water -quality standards. This permit does not require Whole Effluent Toxicity (WET) testing - no permit changes recommended. Renewal Chan,,e Summary: The Permittee has made no changes in processes or WWTP facilities since last renewal. Monitoring and sampling include BOD-5 and Ammonia (summer / winter limits consistent with similar Class -2 WWTPs) plus effluent and instream monitoring for Dissolved Oxygen,and Temperature. According to the renewal application, production volumes for kiln drying are identical to those presented for the previous permit cycle - no permit changes recommended. Proposed Schedule for Issuance: Draft Permit to Public Notice: June 26, 2019 Tentative Scheduled to Issue: August 9, 2019 NPDES Contact: If you have questions regarding the above information or the attached permit, please contact Joe R. Corporon P.G. Doe.c oron@ncdenr.gov] or call his direct line 919-707-3617. NAME: DATE: �_TV Fact Sheet NPDES NCO006548 Pen -nit Renewal Jun2019 Page 2