Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0040946_Application (FTSE)_20190515
State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 - FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: U U 0 4 0 .- (M becompletedby DWRt All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1, Applicants name: City of Durham company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® MunicipaI ❑ Other 3. Signature authority's name: Robert Joyner, PE per 15A NCAC 02T _0106M Title: Development Group Review Manager WCDept ofEnvironmental Quality 4. Applicant's mailing address: 101 Ci�yt _Plaza MAY 15 2019 City: Durham State: NC Zip- 27701- 5. Applicant's contact information; Raleigh RegionaI Office Phone number; (9l9 560- 4326 Email Address: Roberf.joyner;;dl-rhomnc.gov 11. PROJECT INFORMATION: 1 _ Project name: Belgreen Subdivision 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 _. _ and issued date. If new construe Iion but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Durham 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.934093' Longitude--78,900964" 5. Parcel ID (if applicable): 155640, 201868, 155676 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: L Professional Engineer. Bradley Rhinchalt License Number. 21543 Firm: McAdams Mailing address: 2905 Meridian Parkwa City: Durham State: NC Zip: 27713- Phone number: (219) 3361-5000 Email Address: rhinehalt a mcadamsco.com IV, WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. facility Name: Triangle WWTP Permit Number. NCO026051 Owner Name: Durham County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): I. Permit Number(s): WQ Built Before 1984 Downstream (Receiving) Sewer Size: 8 inch System %Vide Collection System Permit Number(s ifaa licahle�: WQCS 00038 Owner Name(s): Durham County FORM: FTA04-16 Pagel of5 VI:' GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No OWA 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®NIA 3. If the Applicant is a Ilomell'roperty Owners' Association, has an Operational Agreement (FORM: HOA) been attached'? ❑ Yes ❑No ®N/A 4. Origin nfwastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial %Commercial % Industrial (See _15A NCAC 02T .0103(20)) bIs there a Pretreatment Program in effect? [:]Yes [:]No 6. I las a flow reduction been approved under 15A NCAC 02T .0l 14(f)? ❑ Yes ®No D If yes, provide a copy of Ilow reduction annroval letter 7. Summarize wastewater generated by project: Establishment Type (see 22T91140 Daily Design Flow' a No. of Units Flow Single Family homes (3 Bedrooms) 360 gal/home 90 32,400 GPD gall GPD gal/ GPD gal/ GPD gat/ GPD gal/ GPD Total 32,400 GPD V// a See 15A NCAC 02T .0114(b), (d), (c)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in blc 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operatic attems, and other measured data. 8. Wastewater generated by project: 32.400 GPD (per 15A NCAC 02T .0114) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why- ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: 1•"1"A 04-16 Page 2 of 5 t VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) • 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted-. Size (inches) Length (feet) Material 8 2,894 PVC ➢ Section 11 & Ill of the MDC for Permitting of Gravity Sewers contains information related to design criteria D Section III contains information related to minimum slopes for gravity sewer(s) D Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII, PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Puma Stations/Force NIalns): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1, Pump station number or name: 2. Approximate Coordinates (Decimal Degrees)- Latitude; . , Longitude: - 3, Design flow of the pump station_ millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s); gallons per minute at __ _ feet total dynamic head (TDI I) 5. Summarize the force main to be permitted (for this Pump Station): Size (incites) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1); ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_ D Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day D Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 021' .0305(h)(1)(C): z It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage_ FORM; FTA 04-16 Page 3 of 5 • • . IX1 SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(t)): I. Does the project comply with all separations found in 15A NCAC 02T.0305(f) & (g) ® Yes [:]No S- 15A NCAC 02T.0305(f) contains minimum scoarations that shall be nrovided for sewer systems: Setback Parameter* Sc aration Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class If impounded reservoirs used as a source of drinkin4 water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal hijzh water or tide elevation) and wetlands sec item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches 15A NCAC 02T.0305(e) contains alternatives where separations in Q2T.0305(t) cannot be achieved. **Stream classifications can be identified using the Division's NC Surface Water Classifications webpag D If noncompliance with 02T.0305(f) or (g) sec Section X of this application 2. Does the project comply with separation requirements for wetlands! (50 feet of separation) ® Yes ❑ No ❑ NiA > See die Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction D As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per I5A NCAg 02B .0200? ® Yes ❑ No ❑ N/A D This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? Y Information can be obtained from the 401 & Buffer Permitting; Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional pcttnits/certifications)? ® Yes ❑ No Per I5A NCAC_ 02T,0105(c)(6}, directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A z If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual Sysiem-Wide Collection permit. FORM: tTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Desitrn Criteria for the Permitting of Puma Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria 0wesi version} as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the reguest is required prior to submittal of the Fast Track Application and supportine documents. 2. Professional Engineer's Certification: I, _._b9AC) (--" �- �L attest that this application for (Professional Engineer's name from Application Item Ill.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). AIthough other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design_ NOTE In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. I f i I � t North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): R ..Ailyo Fess/." "7 21543 r • _� GIN I,Robert N. Joyner, JR P. E. Development Review Group Manager attest that this application for (Signature Authority's name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fin of to xcccd $10,000 as well as civil penalties up to $25,000 per violation. 11 Signature: _ Date; 3 va FORM: FTA 04-16 Page 5 of 5 State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: City of Durham Project Name for which flow is being requested: Belgreen Subdivision More than one FTSE may be required for a single project if the owner of the 11-7'TP is not responsiblefor till pump stations along the route of the proposed wasteirater jlow 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Triangle Wastewater Treatment Plant b. WWTP Facility Permit #: NCO026051 Aft flows are in MGD c. WWTP facility's permitted flow 12 d. Estimated obligated flow not yet tributary to the WWTP 2.239 e. WWTP facility's actual avg. flow 4.788 f. Total flow for this specific request 0.0324 g. Total actual and obligated flows to the facility 7.059 h. Percent of permitted flow used 58.83 11. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) Design Pump Average Daily Station Firm Flow" (Name or Capacity, (Firm.' po, Number) MGD MGD N/A (B) (C) (D)�(B+C) (E)=(A-D) Obligated, Approx. Not Yet Total Current Current Avg. Tributary Flow Pius Daily Flow, Daily Flow, Obligated Available MGD MGD Flow Capacity's** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the NYWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Durham County Sewer Downstream Permit Number: WQCS00038 Pagel of6 FTSE 0.1-16 I11. Certification Statement: I Stephanie Brixey _ _ certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflgws or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing Official Signature 0 Date - Page 2 of 6 PTS E 04-16 di wi ffi-,Jw�- ; �#&t f�q-u dr �Z,N A� w 40, pizv ME 14T 4 1 :-1r �V ARV im .�.. �� jr �►IN �f�. �� Ar BELGREEN SUBDIVISIC USGS TOPO MAP 9 nnn d nnn ddP► loe%lr is. 1 Ct►1 .A `lncn r; �{ tix .� ter% '.�• �'. �[�C.Y�\ r•+ , `+, ,'�+, re rSi . IF 'J�, `rt 1,1 y`t Ir + .. - PA `R �1n\)y^li3EJ='°i• r •'4'd'�¢L-ulyc�CL�%LiL1eI x.=.'�'�'IAYJ�' -'_y'� " �'C`��9't a fF Y # rJr PUBLIC WORKS CITY OF DURHAM May 7, 2019 N.C. Department of Environmental Quality Division of Water Resources Raleigh Regional Office 1628 Mail Service Center Raleigh, NC 27699-1628 Dear Sir/Madam: Subject: Sewer Permit Application -Public Belgreen Subdivision NC Dept of Environmental Quality MAY 15 2019 Raleigh Regional Office C Please find enclosed the subject application package, which includes the original and one copy of the public completed application form (FTA 04-16) and two flow acceptance letters, (form FTSE-04-16 from the City of Durham and Durham County), the appropriate topographic maps, and the $480.00 fee for the application. Should you have questions or comments, please do not hesitate to contact me at (919) 560-4326, ext. 30284. Manager City of Durham Dept. of Public Works 101 City Nall Plaza, Third Floor, Durham, NC 27701 919.560.4326 DurhamNC.gov Follow Us @C© o© rhamNNCC WADAMS March 26, 2019 NCDEQ—DWR Raleigh Regional Office 1628 Mail Service Center Raleigh, North Carolina 27699-1628 RE: Belgreen Subdivision Durham, North Carolina LEN-17050 COVER LETTER > LEN-17050 NC Dept of Environmental Quality MAY 15 2019 Raleigh Regional Office The accompanied Fast -Track Application (FTA 04-16) includes 2,894 lineal feet of 8" PVC gravity sanitary sewer for the proposed Belgreen Subdivision development located at the intersection of Fayetteville Road and Belgreen Road in Durham, NC. The sewer system will be a public system owned and operated by the City of Durham. A letter of transmittal has been provided with detailed description of items included in submittal. Sincerely, MCADAMS Bradley Rhinehalt, PE Senior Project Manager, Residential creating experiences through experience 2905 Meridian Parkway, Durham, NC 27713 1919. 361. SODD ' State of North Carolina Department of Environmental Quality Division of Water Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: City of Durham Project Name for which flow is being requested: Belgreen Subdivision More than one FTSE may be required for a single project if the owner of the FP7VTP is not responsible for all pump stations along the route of the proposed wasteivater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: _ b. WWTP Facility Permit #: All flows are in MGD c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used IL Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D) v(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Apprux. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** No pump stations involved, existing downstream sewer main frm point of tie—in to point nf rrnncfPrtn Durham County main is gravity _flow with sufficient ca an rit - to serve proposed extension. * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Downstream Permit Number: Page I of 6 FTS F 04-16 III. Certification Statement: I Robert N. Jo er, Jr., P.E. certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indioaiN acceptance of this wastewater flow. Signing Official !9 Date Page 2 of 6 USE 04-16