Loading...
HomeMy WebLinkAbout20150378 Ver 2_401 Application_20190610CONDITIONS OF APPROVAL m RESEARCH TRIANGLE PARK.. NORTH CAROLINA 1. FOR S17ES CONTAINING FLOODPLAIN. ALL DEVELOPMENT WITHIN THE FLOODWAY OR NON -ENCROACHMENT AREA OR FLOODWAY FRINGE AND NON -ENCROACHMENT AREA FRINGE, INCLUDING FILL, NEW CONSTRUCTION, SUBSTANTIAL IMPROVEMENTS, MANUFACTURED HOUSING, STORAGE OF MATERIALS AND STORAGE OF TOXIC OR FLAMMABLE SUBSTANCES, IS PROHIBITED EXCEPT AS PROVIDED BY APPLICABLE FLOOD HAZARD REGULATIONS OF UDO SECTION 3.22 AND 8.4. FLOODPLAIN ELEVATION(S) 309 FLOODPLAIN ZONE AE' FEMA MOP NUMBER #3720074800K FEMA MAP DATE OCTOBER 19, 2018 2. NCDWQ BUFFER AUTHORIZATION NOTE.- BUFFER AUTHORIZATION BY THE NORTH CAROLINA DIVISION OF WATER QUALITY (NCDWQ) IS REQUIRED PRIOR TO CONSTRUCTION DRAWING APPROVAL. SITE PLAN CHANGES OCCURRING AS A RESUL T OF AL TERA TIONS NEEDED TO RECEIVE BUFFER AUTHORIZA TION MA Y RESUL T IN THE NEED FOR A SITE PLAN AMENDMENT OR A NEW SITE PLAN BASED ON THE SCOPE OF THE REQUIRED CHANGES. IF A SITE PLAN AMENDMENT OR NEW SITE PLAN IS REQUIRED IT MUST BE APPROVED PRIOR TO CONSTRUCTION DRAWING APPROVAL. CONTACT THE DURHAM CITY -COUNTY PLANNING DEPARTMENT AT 919-560-4137 TO DETERMINE IF A SITE PLAN AMENDMENT OR A NEW SITE PLAN WILL BE REQUIRED. J. STREAM BUFFERS. 50 FOOT WIDE UNDISTURBED STREAM BUFFER, MEASURED FROM TOP OF BANK, EACH SIDE OF STREAM. NO CLEARING OR GRADING OTHER THAN SELECTIVE THINNING AND ORDINARY MAINTENANCE OF EXISTING VEGETATION PERMITTED, EXCEPT IN ACCORDANCE W1TH 15A NCAC 028.233 (6) VEGETATION MANAGEMENT. NO STRUCTURES OR FEATURES REQUIRING GRADING OR CONSTRUCTION MAY BE BUILT WITHIN THE 10 -FOOT STREAM BUFFER SETBACK. ANY USE ALLOWED BY SECTION 8.5.5 OF THE UDO SHALL BE DESIGNED AND CONSTRUCTED TO MINIMIZE THE AMOUNT OF INTRUSION INTO THE STREAM BUFFER AND TO MINIMIZE CLEARING, GRADING, EROSION AND WATER QUALITY DEGRADATION. (UDO SECTION 8.5) 4. FOR S17ES CONTAINING WETLANDS.• STATE AND FEDERAL PERMIT AUTHORIZATION MAY BE REQUIRED FROM THE NC DENR, NC DWQ, AND THE US ARMY CORPS OF ENGINEERS PRIOR TO THE COMMENCEMENT OF ANY LAND DISTURBING ACTIVITIES IN OR NEAR A LAKE, STREAM, CREEK, TRIBUTARY OR ANY UNNAMED BODY OF WATER AND ITS ADJACENT WETLANDS. (UDO SECTION 8.9) 5. WETLAND BUFFER NOTE. • 25 FOOT WIDE WETLAND BUFFER TO REMAIN IN NATURAL, UNDISTURBED VEGETATION. WETLAND BUFFERS MAY BE USED FOR PASSIVE RECREATIONAL ACTIVITIES, SUCH AS WALKING AND BICYCLING TRAILS, PROVIDED THAT SERVICE FACILITIES FOR SUCH ACTIVITIES, INCLUDING BUT NOT LIMITED TO PARKING, PICNICKING AND SANITARY FACILITIES, ARE LOCATED OUTSIDE OF THE WETLAND BUFFER. ANY USE ALLOWED BY THIS SECTION SHALL BE DESIGNED AND CONSTRUCTED TO MINIMIZE THE AMOUNT OF INTRUSION INTO THE WETLAND BUFFER AND TO MINIMIZE CLEARING, GRADING, EROSION AND WATER QUALITY DEGRADATION. (UDO SECTIONS 8.9) 6. FOR PROJECTS WITH GREENWAYS: ON SITE PLANS.• GREENWA Y PLAT SHALL BE RECORDED, SHOWING METES AND BOUNDS FOR THE GREENWA Y, AND EVIDENCE OF RECORDATION WITH BOOK AND PAGE NUMBER PROVIDED TO THE PARKS AND RECREATION DEPARTMENT, AT TIME OF FIRST FINAL PLAT APPROVAL OR PRIOR TO ISSUANCE OF BUILDING PERMIT, WHICHEVER COMES FIRST. ON PRELIMINARY PLATS.- GREENWAY PLAT SHALL BE RECORDED, SHOWING METES AND BOUNDS FOR THE GREENWAY, AND EVIDENCE OF RECORDATION WITH BOOK AND PAGE NUMBER PROVIDED TO THE PARKS AND RECREATION DEPARTMENT, AT TIME OF FIRST FINAL PLAT APPROVAL. 10. PARKING L07S AND WHEN NO BUILDING PERMIT 1S REQUIRED, PLACE THIS NOTE IN THE SPECIAL COIVD177ONS OF APPROVAL BOX: OWNER/DEVELOPER SHALL NOTIFY THE DURHAM CITY COUNTY PLANNING DEPARTMENT SITE COMPLIANCE STAFF AT THE COMPLETION OF CONSTRUCTION AND LANDSCAPING TO REQUEST AN INSPECTION PRIOR TO USE OF THE FACILITY. 11. LANDSCAPE MULCH. PINE STRAW SHALL NOT BE USED AS MULCH OR GROUNDCOVER WITHIN TEN FEET OF ANY STRUCTURES CONSISTING OF EXTERIOR COMBUSTIBLE CONSTRUCTION AS SPECIFIED BY DURHAM CITY CODE SECTION 46-87. 12. LANDSCAPINGIC.O. STANDARDS N07E. ALL LANDSCAPING MUST BE IN PLACE PRIOR TO REQUEST FOR A CERTIFICATE OF COMPLIANCE. CONTACT DURHAM CITY COUNTY PLANNING DEPARTMENT SITE INSPECTION STAFF FOR INSPECTION. 13. LANDSCAPE RE-INSPEC77ON FEE. EACH LANDSCAPING COMPLIANCE INSPECTION AFTER THE INITIAL INSPECTION WILL INCUR A RE -INSPECTION FEE, STARTING AT $100 + 4% TECHNOLOGY SURCHARGE. EACH SUBSEQUENT RE -INSPECTION WILL INCREASE BY $100 +49 (EXAMPLE 1ST -$104, 2ND $ 208, 3RD -- $312, ETC.). PAYMENT MUST BE RECEIVED BY THE DURHAM CITY COUNTY PLANNING DEPARTMENT PRIOR TO RE -INSPECTION. 14. TREE PROTECTION NOTE (UDO SEC. 8.3.2E). TREE PROTECTION FENCING MUST BE IN PLACE PRIOR TO ANY DEMOLITION, LAND DISTURBANCE, OR ISSUANCE OF A GRADING PERMIT AND SHALL INCLUDE WARNING SIGNS POSTED IN BOTH ENGLISH AND SPANISH, AS FOLLOWS: 'NO TRESPASSING / TREE PROTECTION AREA / PROHIBIDO ENTRAR 1 ZONA PROTECTORO PARA LOS AREOLES': 15. ROOT ZONE PR07EC77ON AREA (UDO SEC. 8.3.2): EQUALS ONE FOOT OF RADIUS FOR EVERY INCH OF DIAMETER OF EXISTING TREES, OR SIX-FOOT RADIUS, WHICHEVER IS GREATER. NO DISTURBANCE ALLOWED WITHIN THIS AREA. AREA MUST BE PROTECTED WITH BOTH TREE PROTECTION FENCING AND WARNING SIGNS. 16. PR07EC77ON OF EXIS77NG VEGETATION (UDO SEC. 8.3): AT THE START OF GRADING INVOLVING LOWERING EXISTING GRADE AROUND A TREE OR STRIPPING OF TOPSOIL, A CLEAN, SHARP, VERTICAL CUT SHALL BE MADE AT THE EDGE OF THE TREE SAVE AREA PRIOR TO OR AT THE SAME TIME AS SILT FENCE AND OTHER EROSION CONTROL MEASURES ARE INSTALLED. THE TREE PROTECTION FENCING SHALL BE INSTALLED ON THE SIDE OF CUT FARTHEST AWAY FROM THE TREE TRUNK AND SHALL REMAIN IN PLACE UNTIL ALL CONSTRUCTION IN THE VICINITY OF THE TREES IS COMPLETE. NO STORAGE OF MATERIALS, FILL, OR EQUIPMENT AND NO TRESPASSING SHALL BE ALLOWED WITHIN THE BOUNDARY OF THE PROTECTED AREA. 17. 7RANSPORTA7701V FACILITY PERMIT- CONSTRUCTION OF A PROPOSED PARKING FACILITY, OR MODIFICATION TO AN EXISTING FACILITY, THAT MEETS OR EXCEEDS THE FOLLOWING THRESHOLD MAY REQUIRE A TRANSPORTATION FACILITY PERMIT FROM NCDENR, DIVISION OF AIR QUALITY, PRIOR TO THE START OF CONSTRUCTION, 1500 SPACES FOR PARKING LOTS; 750 SPACES FOR PARKING STRUCTURES, SUCH AS DECKS OR GARAGES; OR 1000 SPACES FOR A COMBINATION OF SURFACE PARKING LOTS AND PARKING STRUCTURES. CONTACT NC DIVISION OF AIR QUALITY FOR MORE INFORMATION. 18. 577E LIGHTING NO7E.• MEASURES SHALL BE PROVIDED TO PREVENT LIGHT SPILLOVER ONTO ADJACENT PROPERTIES AND GLARE TOWARD MOTOR VEHICLE OPERATORS AND SHALL BE INDICATED ON THE SITE PLAN. EXTERIOR LIGHTS SHALL BE SHIELDED SO THEY DO NOT CAST DIRECT LIGHT BEYOND THE PROPERTY LINE. IN ACCORDANCE WITH THESE STANDARDS.- a. TANDARDS.a. THE MAXIMUM ILLUMINATION AT THE EDGE OF THE PROPERTY LINE ADJACENT TO RESIDENTIAL ZONING IS 0.5 -FOOT CANDLES. b. THE MAXIMUM ILLUMINATION AT THE EDGE OF THE PROPERTY LINE ADJACENT TO NON-RESIDENTIAL ZONING IS 5.0. FOOT CANDLES. c. THE MAXIMUM ILLUMINATION AT THE EDGE OF THE PROPERLY LINE ADJACENT TO A STREET IS 5.0 -FOOT CANDLES. d. THE LEVEL OF ILLUMINATION AS MEASURED IN FOOT CANDLES AT ANY ONE POINT SHALL MEET THE STANDARDS IN THE TABLE IN UDO SECTION 7.4.3A WITH MINIMUM AND MAXIMUM LEVELS MEASURED ON THE PAVEMENT WITHIN THE LIGHTED AREA. e. THE MAXIMUM HEIGHT FOR DIRECTIONAL OR FULL -OFF LIGHTING FIXTURES (FIXTURES DESIGNED TO ENSURE THAT NO LIGHT 1S EMITTED ABOVE A HORIZONTAL LINE PARALLEL TO THE GROUND) SHALL BE 30 FEET ABOVE GRADE (MEASURED TO THE TOP OF THE FIXTURE). f. THE MAXIMUM HEIGHT FOR NON -DIRECTIONAL LIGHTING FIXTURES, WHICH ARE DEFINED AS FIXTURES DESIGNED TO ALLOW LIGHT TO BE EMITTED ABOVE 0 HORIZONTAL LINE PARALLEL TO THE GROUND, SHALL BE 15 FEET ABOVE GRADE (MEASURED THE TOP OF THE FIXTURE). g. THESE STANDARDS MUST BE VERIFIED BY FIELD SURVEY (BY USE OF PHOTOMETRIC SURVEY) PRIOR TO THE CERTIFICATE OF COMPLIANCE BEING ISSUED. ALL THIS INFORMATION, INCLUDING DETAILS. WILL BE REQUIRED ON BUILDING PLANS PRIOR TO ISSUANCE OF BUILDING PERMIT. 19. CITY STORM DRAINAGE EASEMENTS.• SEE PUBLIC WORKS STANDARD NOTES, BELOW. COUNTY STORM OR PRIVATE DRAINAGE EASEMENTS CENTERLINE OF 20 FOOT WIDE DRAINAGE EASEMENT FOR THE BENEFIT OF ADJACENT PROPERTYOWNERS NOT MAINTAINED BY PUBLIC AUTHORITIES. NO BUILDINGS, STRUCTURES, FILLS, EMBANKMENTS OR OBSTRUCTIONS PERMITTED WITHIN THE EASEMENT EXCEPT ACCORDING TO THOSE TERMS. 20. FOR COUNTY SOIL AND EROSION CONTROL: a). A SEDIMENTATION AND EROSION CONTROL PLAN MUST BE SUBMITTED AND APPROVED PRIOR TO THE ISSUANCE OF A LAND -DISTURBANCE PERMIT. b). IF AN OFFSITE SOIL SPOIL OR BORROW SITE IS UTILIZED, THEN THE DISTURBED AREA OF THE SPIL/BORROW SITE MUST BE INCLUDED 1N THE LAND -DISTURBANCE PLAN AND PERMIT UNLESS THE SPOIL/BORROW SITE ALREADY HAS A LAND -DISTURBANCE PERMIT. DATE: APRIL 5.,2019 PROJECT DATA 6 DAVIS DRIVE RESEARCH TRIANGLE PARK, DURHAM COUNTY, NORTH CAROLINA ENGINEER: MCKIM & CREED, INC. VARSITY DRIVE, SUITE 500 RALEIGH, NORTH CAROLINA 27606 PHONE: (919) 233-8091 CONTACT: GRANT LIVENGOOD, PE EMAIL: glivengood@mckimcreed.com SURVEYOR: CREED, INC. MCKIM & VARSITY DRIVE, SUITE 500 RALEIGH, NORTH CAROLINA 27606 PHONE: (919) 233-8091 CONTACT: RANDY RAMBUEA, PLS EMAIL: rrombuea@mckimcreed.com OWNER: ARE -NC REGION NO. 14, LLC (ALEXANDRIA REAL ESTATE) 7020 KIT CREEK ROAD, SUITE 100 RESEARCH TRIANGLE PARK, NC 27709 PHONE: (919) 313-6645 CONTACT: OLIVER SHERRILL EMAIL: osherrill@are.com rA_ VICINITY MAP NTS v v MqKW&CP\EED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com SITE DATA TABLE: OWNER: ARE (ALEXANDRIA REAL ESTATE) PROPERTY IDENTIFICATION NUMBER: 0748-03-02-9361 ZONING: SRP JURISDICTION: DURHAM COUNTY TIER: SUBURBAN TIER RIVER BASIN: CAPE FEAR WATERSHED: JORDAN LAKE (SUBWATERSHED - UPPER NEW HOPE) SITE AREA: DISTURBED AREA: EXISTING DISTURBED AREA = EXISTING IMPERVIOUS AREA: PROPOSED IMPERVIOUS AREA: ENTRY DRIVE: OVERALL IMPERVIOUS AREA: EXISTING BUILDING COVERAGE: MAXIMUM ALLOWABLE BUILDING AREA: SHEET INDEX C0.0 COVER SHEET C0.2 EXISTING CONDITIONS AND DEMOLITION PLAN C1.0 OVERALL SITE PLAN C2.0 FLOODPLAIN PLAN C3.0 EROSION CONTROL PLAN - PHASE 1 C3.1 GRADING, DRAINAGE PLAN & EROSION CONTROL PLAN - PHASE 2 C3.2 CULVERT PLAN & PROFILE D1.0 SITE DETAILS D1.1 SITE DETAILS D2.0 STORM DRAINAGE DETAILS D2.1 STORM DRAINAGE DETAILS D2.2 CULVERT DETAILS D2.3 CULVERT HEADWALL DETAILS CON -13-2 CONTECH ALUMINUM STRUCTURAL PLATE DETAILS (BY OTHERS) CON -13-3 CONTECH ALUMINUM STRUCTURAL PLATE DETAILS (BY OTHERS) CON -134 CONTECH ALUMINUM STRUCTURAL PLATE DETAILS (BY OTHERS) CON -13-5 CONTECH ALUMINUM STRUCTURAL PLATE DETAILS (BY OTHERS) D3.0 EROSION CONTROL DETAILS D3.1 EROSION CONTROL DETAILS 56.228 AC 1.15 AC 6.20 AC / 270,029 SF 0.39 AC / 17,182 6.59 AC / 287,211 SF / 11.7% 2.28 AC / 4.06% 8.43 AC / 15.00% PUBLIC WORKS CONDITIONS OF APPROVAL 1. THE DESIGNING PROFESSIONAL (A NCPE, NCPLS OR NCRLA - AS REQUIRED) SHALL SUBMIT THREE (3) SETS OF CONSTRUCTION DRAWINGS TO THE PUBLIC WORKS DEPARTMENT - DEVELOPMENT REVIEW FOR REVIEW AND APPROVAL. CONSTRUCTION DRAWING APPROVAL IS REQUIRED PRIOR TO COMMENCING CONSTRUCTION (SEE CONSTRUCTION PLAN APPROVAL PROCESS). THE APPROVAL OF CONSTRUCTION DRAWINGS IS SEPARATE FROM SITE PLAN APPROVAL. CITY OFFICIALS SHALL REVIEW ALL SIZES, MATERIALS, SLOPES, LOCATIONS, EXTENSIONS AND DEPTHS FOR ALL PROPOSED UTILITIES (WATERLINES, SANITARY SEWER LINES AND STORM DRAINAGE CONVEYANCE SYSTEMS) FOR COMPLIANCE WITH ALL APPLICABLE REGULATORY STANDARDS, SPECIFICATIONS, AND BEST MANAGEMENT PRACTICES. 2. THE DESIGNING PROFESSIONAL (A NCPE, NCPLS OR NCRLA - AS REQUIRED) SHALL SUBMIT ONE (1) SET OF AS -BUILT DRAWINGS FOR THE PUBLIC WORKS DEPARTMENT - DEVELOPMENT REVIEW FOR REVIEW AND APPROVAL. AS -BUILT DRAWINGS APPROVAL 1S REQUIRED PRIOR TO WATER METER INSTALLATION AND/OR SANITARY SEWER SERVICE CONNECTION AND PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. J. FIRE FLOW ANALYSIS REQUIRED FOR REVIEW AND APPROVAL AS PART OF THE CONSTRUCTION DRAWING APPROVAL PROCESS. TO SCHEDULE FLOW TEST OR TO OBTAIN CURRENT SYSTEM DATE, COMPLETE THE ONLINE APPLICATION (h t tp: //durh am n c. go v/ich/op/p wd/Pages/fire- fl o w. aspx). 4. AN NCDOT OR CITY OF DURHAM DRIVEWAY PERMIT IS REQUIRED. 5. THE LOCATION OF THE SIDEWALKS SHOWN ON THIS PLAN IS SCHEMATIC. A CITY OF DURHAM AND/OR NCDOT ENCROACHMENT PERMIT 1S REQUIRED PRIOR TO ANY CONSTRUCTION. AFTER OBTAINING THE REQUIRED PERMITS, PLEASE CONTACT THE CITY OF DURHAM ENGINEERING CONSTRUCTION INSPECTION OFFICE AT 560-4326 FOR A PRE -CONSTRUCTION CONFERENCE AND FIELD VISIT PRIOR TO ANY WORK ON THE PROPOSED SIDEWALK. 6. AN 8.0' ASPHALT SIDEWALK ARE EXPRESSLY DEDICATED TO USE BY THE GENERAL PUBLIC. UPON CONSTRUCTION OF THE SIDEWALKS IN CONFORMANCE WITH ALL APPLICABLE REQUIREMENTS, CITY COUNCIL MAY ACCEPT THE SIDEWALKS FOR MAINTENANCE BY THE CITY OF DURHAM ("CITY'). ACCEPTANCE OF THE SIDEWALKS BY CITY COUNCIL CONVEYS THE RIGHT IN, OVER, UNDER, AND THROUGH THE SIDEWALKS, NECESSARY TO THE CITY AND ITS AGENTS AND CONTRACTORS, TO MAINTAIN AND REPAIR THE SIDEWALKS IN THE CITY'S SOLE DISCRETION. THE RIGHT OF INGRESS/EGRESS TO THE SIDEWALKS FROM THE PUBLIC RIGHT OF WAY IS ALSO GRANTED TO THE CITY SO THE CITY CAN MAINTAIN AND REPAIR THE SIDEWALK AFTER ACCEPTANCE. THE CITY IN ITS SOLE DISCRETION HAS THE RIGHT TO DETERMINE THE POINTS OF INGRESS AND EGRESS FROM THE PUBLIC RIGHT OF WAY NECESSARY TO PERFORM MAINTENANCE OR REPAIR AFTER ACCEPTANCE. 7. NCDOT DRIVEWAY PERMIT REQUIRED PRIOR TO CONSTRUCTION. CONTACT NCDOT AT 220-4750 FOR REQUIREMENTS. �qRO S 028419 = •. 4/05/2019 p CALL N.C. ONE CALL CENTER BEFORE YOU DIG STOP 1-800-632-4949 AVOID UTILITY \ DAMAGE / PRELIMINARY NOT FOR CONSTRUCTION w ry 0 ry e - z LU LU 0 U) Q 0 cfl O O O i C`7 ti O J z �O V z LU O LL0 LU Z) U) \ \ 171 \l 1\I \\\ \VA� \\���/ ♦ ` V�� e v�� v� V A\ V A\ V A\ vv ��� vvv \ O v' \ \ EX, LIGHT POLE \\ \\ �A \\� V ) A EX. FLOOD HAZARD LINE (TYP.) I \ \ / / \\i % / ,<• A \ �� \\\ XA \ V A V I I \\\\ \V A V I I LL - - V � ♦ � \ / / v- \ \ V AA � � '�' ♦ '�� � 312 \ \ \ O \ !� \ ♦ \ \ / \ �\ \ \ \� ♦ / ` O EX. 10.0' NO BUILD \ \\\ II Q `� u LI N E (TYP.) �_N EX. 50.0' RIPARIAN \ \ \ \ \ \ \ BUFFER LINE (TYP.) \ 310 1 \ \\ \\ \\\\\ v v I 1 OS\ \ \� vv,NN Xx G - \\NE \��\ \\�\X�\�\\ I �- 306- 41% \ 41% pp \ \ y ^ FP �\ 0 -EX. FLOODWAY LINE (TYP.) �� v v � v11111111 1 vv vyyvv � � �III11 11111\ v v ��„ vv�� v \ \� 370 EX. 50.0' RIPARIAN \ X. EX. FLOOD HAZARD BUFFER LINE (TYP.) \ J LINE (TYP.) 6 �EX. 10.0' NO BUILD LINE (TYP.) \ ` -37 `\ ABANDONED SSMH II s�G TOP=309.94 \ ��S - _ m m INV.=UNAVAILABLE �\ 0 14 • F�314r� _ X310 - ��W _ - 310 rL �`�315- - ----_--------- a so -F ---315- ---- ---- - 6 -�-�- ay -----315 *-E"P 0 EX. SSMH - I- -' - - TOP=314.09- - - - EP 31 - INV. (8")=299.87 _ _ g $ �p EXE. 60" RCP 31 c� / RIM ----3D116.77 INV (12" SE)=313.47 I cc) i I I I 1 I I v EX. FIRE v L HYDRANT (TYP.) \ J < EX. DI\\V A / RIM=314.00 \ T I \ \ INV (24" SE)=307.45 y< INV (15" NW)=309.75 \ \ \ \ INV (12" NE)=309.20 INV. (4")=312.68 \ INV (8" SW)=312.63 � \24 RCP\306.46 v Op C p v r O O \ A - S fr1 y _ D Z r EX. CB 1 \ RIM=317.68 / INV (15" NE)=313.93 A I INV (15" SW)=312.25 INV (10" NW)=312.24 � SSMH �A TOP=321.79 EX. WATER METER \ INV. (8" NE)=312.04 LEGEND: INV. (8" SE)=312.04 VAULT (TYP.) \\ �A \ �A \ - - EX. PROPERTY BOUNDARY � ABANDONED SSMH EX. RIPARIAN BUFFER LINE EE \ Fp � TOP=314.67 EX. 10.0NO BUILD LINE A� INV. (8")=311.47 INV. (8")=311.27 y \ TFO EX. TELEPHONE FIBER OPTIC LINE EX. FLOOD HAZARD � � LINE (TYP.) FO EX. FIBER OPTIC LINE EX. SIGN (TYP.) ��� '� 7 \ `Fp ATT EX. AT&T LINE \ o G EX. GAS LINE �Fp � I \ € G)� E \ - - - EX. EASEMENT LINE \ EX. FIRE HYDRANT TYP. _ \� ( ) EX. STREAM CENTERLINE F - - - EX. EASEMENT LINE �\ 12 \�j EX. GAS LINE (TYP.) EX. STORM DRAINAGE PIPE / 13 j� EFS EXISTING 100 -YR FLOODPLAIN A INV. (8 )=299.67 \ \ EX. 16" WATER MAIN (TYP.) 7 EF 15 V ��� 2 / EX. SSMH MCKIM & CREED PNT 2 � \ # ,, '` � ti / 11 TOP=311.93 \ REBAR AND CAP SET / -n INV. (N)=301.53 _ - GRID COORDINATES / - - - - N=782,097.36' _ - - - - - - -EF / INV. (W)=305.00 - - - - _ E=2,041,763.86' - - - \ /` / INV. (S)=300.62 - - - (NAD 83/2011) ELEV.=315.23 EX. DI dy / DAVIS DRIVE (NAVD88) �y �`Q�FP TOP=315.66 (SR -1999 - 150' PUBLIC R/W) INV. (15")=312.55 i SEAL A ISSUED FOR PERMIT 2019.04.05 REV.NO. DESCRIPTIONS DATE REVISIONS SEAL CARO��ti, , \ �pEES L _ 028419 _= 4/05/2019 14 z �_ -� FW EXISTING FLOODWAY _ W :17 EXISTING 100 -YR FLOODPLAIN 56 9 A EX. WATER VAULT (TYP.) - - - - - - - - ' _ FW REVISED FLOODWAY SS SS �- - - �� - SS -SSFP EFFECTIVE FUTURE 100 -YR FLOODPLAIN - 0� 0� 0_j N POST PROJECT FUTURE 100 -YR FLOODF 60" RCP _ - -S97'W625.58'(GROUN - U EP EX. EDGE OF PAVEMENT CF=0.9999263 25.53'(GRID) F ^ ® EX. FIBER OPTIC BOX EX. SANITARY SEWER MANHOLE EX. DI X315 11 TOP=314.18i C 0 EX. TELEPHONE PEDESTAL INV. (15")=311.20 53 ss EX. SANITARY SEWER PIPE FG�EX.FIBER OPTIC LINES - _ _ _- EX. PUBLIC WATER MAIN LIN LINE (TAP.) _ p � (CONTRACTOR TO POT -HOLE EXISTING � I z EX. FIRE HYDRANT FIBER LINES AND CONFIRM EXISTING y VERTICAL ELEVATIONS IN AREA OF 491 EX. CONTOUR LINE PROPOSED ENTRY DRIVE) ` _ ' ^ r 0 EX. SIGN °I EX. TREE v v &CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA KEY NOTES: O EXISTING 16" WATER LINE TO BE PROTECTED. O EXISTING FIBER OPTIC LINES TO BE PROTECTED. O FIBER OPTIC PEDESTAL TO BE RELOCATED. CONTRACTOR TO COORDINATE WITH LOCAL UTILITY COMPANY. O4 EXISTING TELEPHONE PEDESTAL TO BE RELOCATED. CONTRACTOR TO COORDINATE WITH UTILITY COMPANY. O5 EXISTING SANITARY SEWER MANHOLE TO BE ADJUSTED TO PROPOSED GRADES. REFER TO SHEET C3.2. O6 EXISTING SANITARY SEWER MANHOLE TO BE PROTECTED. O7 EXISTING SANITARY SEWER LINE TO BE PROTECTED. O8 EXISTING CONDUITS TO BE PROTECTED. O9 EXISTING ASPHALT PATH TO BE REMOVED AND REPLACED PER PLANS. REFER TO SHEETS C1.0 AND C3.1. 10 EXISTING 60" RCP TO BE PROTECTED AT ALL TIMES. 11 ASPHALT PAVEMENT TRANSITION. REFER TO DETAIL SHEET D2.X. 12 EXISTING WATER VAULT TO BE PROTECTED. 13 EXISTING FIRE HYDRANT ASSEMBLY TO BE PROTECTED. 14 EXISTING SIGN AND BIRD HOUSE TO BE RELOCATED. 15 EXISTING TELECOM MANHOLE TO BE ADJUSTED TO PROPOSED GRADES. REFER TO SHEET C3.2. GENERAL NOTES: 1. THIS PROPERTY IS ZONED SRP (SCIENCE RESEARCH PARK). 2. CURRENT LAND USE: INDUSTRIAL/ENVIRONMENTAL SCIENCE. 3. ALL DISTANCES SHOWN ARE HORIZONTAL GROUND MEASUREMENTS. 4. EXISTING TOPOGRAPHIC DATA IS BASED ON DESIGN INFORMATION BY McKIM AND CREED INC. AND SURVEY PERFORMED BY McKIM AND CREED INC. ON APRIL 4, 2018 THRU APRIL 9,2018. 5. PROJECT IS LOCATED WITHIN THE WATERSHED CONSERVATION OVERLAY DISTRICT: CAPE FEAR RIVER (SANFORD) WS -IV PROTECTED AREA (CFS -WS -IV -PA). 6. A PORTION OF THIS PROPERTY IS LOCATED IN SPECIAL FLOOD HAZARD AREA "AE" AS SHOWN ON FEMA FIRM MAP #3710966600J DATED FEBRUARY 2, 2007. DEMOLITION NOTES: 1. NO EARTH -DISTURBING ACTIVITIES SHALL COMMENCE UNTIL ALL PERIMETER EROSION CONTROL MEASURES ARE IN PLACE IN ACCORDANCE WITH THE EROSION CONTROL SEQUENCE SHOWN IN THESE PLANS. 2. CONTRACTOR IS RESPONSIBLE FOR REPAIRS OF DAMAGE TO ANY EXISTING IMPROVEMENTS, AT HIS EXPENSE, DURING CONSTRUCTION, SUCH AS, BUT NOT LIMITED TO, DRAINAGE, UTILITIES, PAVEMENT, STRIPING, CURB, ETC. REPAIRS SHALL BE EQUAL TO OR BETTER THAN EXISTING CONDITIONS. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING THE PUBLIC DURING CONSTRUCTION, WHICH INCLUDES, BUT IS NOT LIMITED TO, CONSTRUCTION FENCING, BARRICADES, SIGNAGE, ETC. 4. CONTRACTOR SHALL COMPLY TO THE FULLEST EXTENT WITH ALL REGULATIONS GOVERNING THE DEMOLITION, REMOVAL, TRANSPORTATION AND DISPOSAL OF ALL DEMOLITION DEBRIS. 5. CONTRACTOR SHALL COMPLY TO THE FULLEST EXTENT WITH THE LATEST OSHA STANDARDS FOR EXCAVATION AND TRENCHING PROCEDURES. CONTRACTOR SHALL USE SUPPORT SYSTEMS, SLOPING, BENCHING, ETC. AS NECESSARY FOR THESE OPERATIONS, AND SHALL COMPLY WITH ALL OSHA PERFORMANCE CRITERIA. 6. CONTRACTOR SHALL TAKE SPECIAL CARE TO PROTECT ALL UTILITIES AND APPURTENANCES TO REMAIN. EXISTING CONDITIONS/DEMOLITION PLAN CALL N.C. ONE CALL CENTER BEFORE YOU DIG STOP 1-800-632-4949 AVOID UTILITY NORTH DAMAGE 30' 0 30' 60' SCALE: 1"=30' (Horiz.) CITY OF DURHAM PUBLIC WORKS DEPARTMENT APPROVED ENGINEERING DATE STORM WATER DATE TRANSPORTATION DATE DATE DATE DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 DRAWN DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML SCALE M&C FILE NUMBER C0.2 HORIZONTAL: DRAWING NUMBER 1 "=30' VERTICAL: CO.2 N/A STATUS: REVISION NOT FOR CONSTRUCTION A ISSUED FOR REVIEW ONLY SITE GENERAL NOTES: 1. PROTECT ALL ADJACENT PROPERTIES, THE GENERAL PUBLIC, AND ALL OF THE OWNER'S FACILITIES. SHOULD DAMAGES OCCUR, CONTRACTOR SHALL REPAIR IMMEDIATELY AS DIRECTED BY THE ARCHITECT/ENGINEER. 2. CONTRACTOR SHALL HOLD HARMLESS THE OWNER AND THE ARCHITECT/ENGINEER FOR DAMAGES, INJURIES OR OTHER ACCIDENTS WHICH OCCUR DURING THESE CONSTRUCTION ACTIVITIES. 3. ALL ELEVATIONS ARE IN REFERENCE TO DESIGNATED BENCHMARKS/CONTROL POINTS. CONTRACTOR IS TO MAINTAIN ALL BENCH MARKS, MONUMENTS AND OTHER REFERENCE POINTS. CONTRACTOR SHALL REESTABLISH, AT NO COST TO OWNER, ANY SUCH REFERENCE POINT IF DISTURBED OR DESTROYED. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATION OF ALL ILLUSTRATED CONSTRUCTION ACTIVITIES AT THE JOB SITE. 5. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE RULES AND REGULATIONS GOVERNING THE CONSTRUCTION INDUSTRY, INCLUDING BUT NOT LIMITED TO THOSE PERTAINING TO TRAVELING OPERATIONS AND OSHA. PROVIDED THE CONTRACTOR IS NOT IN COMPLIANCE WITH ANY APPLICABLE REGULATIONS, THE CONTRACTOR SHALL NOT BE ALLOWED TO RESUME CONSTRUCTION ACTIVITIES UNTIL THE ISSUES ARE FULLY RESOLVED TO THE SATISFACTION OF THE AUTHORITIES HAVING JURISDICTION. NO ADDITIONAL COMPENSATION WILL BE DUE TO THE CONTRACTOR FOR LOST TIME, PRODUCTION OR PROFIT DUE TO THE WORK STOPPAGES RESULTING FROM CONTRACTOR'S NONCOMPLIANCE WITH APPLICABLE REGULATIONS. 6. UTILIZE SIGNS, BARRICADES, FLAGMEN, OR GUARDS AS REQUIRED TO ENSURE THE SAFETY OF ALL VEHICULAR AND PEDESTRIAN TRAFFIC DURING ALL CONSTRUCTION ACTIVITIES. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT OF ALL WORK AS ILLUSTRATED ON PLANS. IF EXISTING CONDITIONS DIFFER FROM THOSE ILLUSTRATED ON PLANS, NOTIFY ENGINEER PRIOR TO CONSTRUCTION. 8. VERIFY ALL DIMENSIONS AND GRADES AT THE JOB SITE. IN THE EVENT DISCREPANCIES ARE NOTED, NOTIFY ARCHITECT/ENGINEER SO THAT MODIFICATIONS TO THESE DRAWINGS CAN BE MADE. 9. CONTRACTOR SHALL OBTAIN ALL NECESSARY LICENSES AND PERMITS REQUIRED TO COMPLETE THE WORK INCLUDED IN THE CONTRACT DOCUMENTS AT THE CONTRACTOR'S EXPENSE UNLESS PREVIOUSLY OBTAINED BY THE OWNER. IF REQUIRED, CONTRACTOR SHALL OBTAIN A HAUL ROUTE PERMIT FOR ALL OFF-SITE TRANSPORTATION ACTIVITIES. 10. ANY CHANGES OR MODIFICATIONS TO THE PROJECT PLANS SHALL FIRST BE APPROVED BY THE ARCHITECT/ENGINEER. 11. CONTRACTOR SHALL ENSURE PROPER DISPOSAL OF CONSTRUCTION SITE WASTE MATERIALS. 12. ALL DIMENSIONS ARE TO EDGE OF PAVEMENT AND FACE OF CURB UNLESS OTHERWISE NOTED. 13. ALL TRAFFIC CONTROL DEVICES, INCLUDING BUT NOT LIMITED TO PAINT STRIPPING, PAVEMENT MARKINGS, AND SIGNAGE SHALL CONFORM TO THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" OR AS REQUIRED IN SPECIFICATIONS. 14. CONTRACTOR SHALL MATCH EXISTING PAVEMENT IN GRADE AND ALIGNMENT. \ \X6 � T `a\ a ♦ FQ � , ♦ 3 , w >� \ 100' SETBACK (TYP.) EX. FLOOD HAZARD LINE (TYP.) EX. RIGHT-OF-WAY (TYP.) — — — — — — — y — — EX. FLOOD HAZARD LINE (TYP.) EX. 50.0' RIPARIAN BUFFER LINE (TYP.) EX. 10.0' NO BUILD LINE (TYP.) o��N CARO 028419 4/05/2019 Q v v &CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www mrkimrrPPr1 rnm EX. FLOOD HAZARD LINE (TYP.) 100' SETBACK (TYP.) EX. ASPHALT DRIVE (TYP.) LEGEND: KEY NOTES: 1O STANDARD ASPHALT PAVEMENT: REFER TO DETAIL SHEET D1.2. 2O CONCRETE SIDEWALK. REFER TO DETAIL SHEET D1.0. O3 CONCRETE SIDEWALK EXPANSION JOINTS (TYP). REFER TO SIDEWALK DETAIL ON DETAIL SHEET D1.0. 4O 24" STANDARD CURB AND GUTTER: REFER TO DETAIL SHEET D1.0. O5 CONCRETE ACCESSIBLE RAMP. REFER TO DETAIL SHEET D1.1. O6 6" LANE STRIPING: USE HIGHWAY MARKING PAINT - WHITE (2 COATS). PER NCDOT STANDARDS AND SPECIFICATIONS. REFER TO DETAIL SHEET D1.1. O7 24" WIDE STOP BAR PER NCDOT STANDARDS. STOP BARS SHALL BE PAINTED WITH 2 COATS OF WHITE TRAFFIC MARKING PAINT. REFER TO DETAIL SHEET D1.1. O8 TRAFFIC ARROW PER NCDOT STANDARDS. ARROWS SHALL BE PAINTED WITH 2 COATS OF WHITE TRAFFIC MARKING PAINT. REFER TO DETAIL SHEET D1.1. 9O STOP SIGN R1-1. PER NCDOT STANDARDS AND SPECIFICATIONS. REFER TO INSTALLATION AND MOUNTING DETAIL ON SHEET D1.1. 10 HIGH -VISIBILITY CROSSWALK. LINES SHALL BE 24" WIDE x 6' LONG WHITE PAINTED AS PER NCDOT STANDARDS. REFER TO DETAIL D1.1. 11 LANDSCAPED AREA (TYP.). CONTRACTOR TO COORDINATE WITH THE OWNER. 12 EXISTING EDGE OF PAVEMENT (TYP.). 13 MATCH EXISTING ASPHALT PAVEMENT (TYP.). 14 CONCRETE SIDEWALK CONTRACTION (SAW) JOINTS (TYP). REFER TO SIDEWALK DETAIL ON DETAIL SHEET D1.0. 15 TEMPORARY BARRICADES. SEE DETAIL SHEET D2.1. 16 TEMPORARY SIDEWALK CLOSED SIGN. 17 30" STANDARD CURB AND GUTTER. REFER TO DETAIL SHEET D1.0. 18 8.0' ASPHALT GREENWAY. 19 10' X 70' SIGHT TRIANGLE (TYP.). 20 FUTURE PHASE (NOT IN THIS CONTRACT). 21 PROPOSED ENTRY SIGN (BY OTHERS). 22 EXISTING 8.0' ASPHALT GREENWAY (TYP.). 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA OVERALL SITE PLAN CALL N.C. ONE CALL CENTER BEFORE YOU DIG STOP 1-800-632-4949 A:DAM D UTILITY NORTH AGE 30' 0 30' 60' SCALE: 1"=30' (Horiz.) CITY OF DURHAM PUBLIC WORKS DEPARTMENT APPROVED ENGINEERING DATE STORM WATER DATE TRANSPORTATION DATE DATE DATE DATE: EX. PROPERTY BOUNDARY MCE PROJ. # EX. RIPARIAN BUFFER LINE DRAWN EX. 10.0' NO BUILD LINE — — — EX. EASEMENT LINE CHECKED EX. STREAM CENTERLINE — — — EX. EASEMENT LINE EXISTING 100 -YR FLOODPLAIN EFIP EXISTING FLOODWAY FW EXISTING 100 -YR FLOODPLAIN REVISED FLOODWAY EFFECTIVE FUTURE 100 -YR FLOODF FP POST PROJECT FUTURE 100 -YR FL BARRICADE EX. EDGE OF PAVEMENT EX. SIGN EX. TREE EXISTING RIPARIAN BUFFER AREA 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA OVERALL SITE PLAN CALL N.C. ONE CALL CENTER BEFORE YOU DIG STOP 1-800-632-4949 A:DAM D UTILITY NORTH AGE 30' 0 30' 60' SCALE: 1"=30' (Horiz.) CITY OF DURHAM PUBLIC WORKS DEPARTMENT APPROVED ENGINEERING DATE STORM WATER DATE TRANSPORTATION DATE DATE DATE DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 DRAWN DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML SCALE M&C FILE NUMBER HORIZONTAL: DRAWING NUMBER 1 "=30' VERTICAL: v l 1 .0 N/A STATUS: REVISION NOT FOR CONSTRUCTION A ISSUED FOR REVIEW ONLY \ \ \ \ \ \ \ \ \ \ \ \ 6 Davis Drive - Entrance Drive ///// \ \\ \ \\ \ \ \\\ / _ 07473-0001 \ \ \ \ // Floodplain Development Permit \\o\ \ \ \\ \ \ \ \ \\ / / / ` \ \ \\ \ \ \ 2/15/19 / / ` \ \ \ \ ` \ \ /\ Floodplain and Floodway Impacts / / Data Area (SF) Area (AC) �\ \\ \\ \ \ \ \ / \ \ \ ✓ Site Area 2449, 31354 5623 A The amount of floodplain area within the project site 545,608.90 12.53 B The percentage of floodplain area within the project site 22.3% _- --C The amount of floodplain area previously filled ordeveloped (if known) 32066.28 0.74 EX. 10.0' NO BUILD \ \ \ \ \ -- \ LINE (TYP.) \ D The percentage of floodplain area previously filled ordeveloped (if known) 5.9% \ \ � / E The amount of floodplain development proposed 23,755.61 0.55 F The percentage of floodplain development proposed 4.4% EX. 50.0' RIPARIAN \ \ G The amount of floodplain area fill proposed 20,450.74 0.47 BUFFER LINE (TYP.) \ EFFECT/VE FUTURE 100-�R POST -DEVELOPMENT 100 -YR H The percentage of floodplain area fill proposed 86.1% FLOODPLAIN PER WARD \ FLOODPLAIN \ CONSULTING ENGINEERING PC PER WARD CONSULTING / I The amount of floodway area within the site 39,212.54 0.90 \V / \\ \ \ \ \ \ , ANALYSIS (TYP.) \ \ ENGINEERING, PC ANALYSIS (TYP.) \ \\ // J The percentage of floodway area within the site 1.6% \ \ \ \ \ \ K The amount of floodway area previously filled ordeveloped (if known) 0 0.00 L The percentage of floodway area previously filled or developed (if known) 0 0.00 M The amount of floodway area development proposed 9,394.50 0.22 N The percentage of floodway area development proposed 24% L \ \\\\ \\\ \ �j POST -DEVELOPMENT FLOODWAY \ PER WARD CONSUL TING \ \ \ \ \ O The amount of floodway area fill proposed 8,948.14 0.21 ENGINEERING, PC ANALYSIS (TYP.) \ - \ N / o \ / - - - \ \ \\ \ / - / / P The percentage of floodway area fill proposed 23/ Q I \ \ \\\\ \\\ \ 3 S\ \"I Q If floodway development is proposed, submit a no -rise flood certificate I \ \ \ \ \ \ � POST -DEVELOPMENT FUTURE 100 -YR A\\ \ V I FLOODPLAIN \\\� \ \ \ \ \ PER WARD CONSULT/NG ENG/NEER/NG, Q - - - - - - - - \ Area in floodplain previously developed 9,673.66 0.22 \\\� \ ' \ \ \ PC ANA YS/S (TYP.) - \ Area in flood Iain previously filled 2,199.64 0.05 \ \ \ \ \ \ \� _ _ _ / p p Y \\N\ I \ \ \ \ I \ \\\ \ % TA \ \ \ EX. FLOOD HAZARD \ r �� \ \\N \� O \ O LINE (TYP.) I I _ _ \ `-`- - \ I ❑ I F \\\\\ \ \ \ \\ \ \ \ \ ���\� \\\ \\ '� TA \ \ �O� 9\ \ I GP 9 \ \ \ L _ \\� \\ \ \\ \ \ \ \ \ II I � \\ \ ` - \ \ I ARE -NC REGION N0. 14 LLC \ \ \ \ \ I I // PIN: 0748-03-02-7196 PRE -DEVELOPMENT DB 6902, PG 392-396 \\ �\ ` �A \ FL OOD WA Y (TYP.) \ \ \ \ I I I \ \ \ \ \ I I / PB 11 PG 362-365 \\�\\ - \ \ \ \ L L / 1,857,024 SF \\\\ \\ \\ \ \ \ �/ \ 7 < 42.63 ACRES \ \ / \\\\ \ \ \ \ \ \ -P� LIMITS OF \ \ \ \ \ < / \ �A 06, EX. 1 D. 0' NO BUILD \ \ I I � 11 DISTURBANCE (TYP.� \ \ \ \ \ \ \ \ I \ \X\\ / Tp LINE (TYP.) I \ v I \ \ \ \ \ \ \ \ \ EX. 50.0' RIPARIAN BUFFER LINE (TYP.) Low - lop -'-306-/ / FP O v '® PRE -DEVELOPMENT �- / I II II I I I //� O\ \\�\ \ /� S ,� 1, FLOOD WAY (TYP.) POST -DEVELOPMENT FLOODWAY �y ' NII ,cam \ \ \ \ IIIIII PER WARD CONSUL TING oy \ \ \ I ENGINEERING, PC ANALYSIS (TYP.)\\ v 10 II II I (\ v EX. 50.0' RIPARIAN / IIIII IIIII \ v \ / EX.FLOOD HAZARD / \ \ \ \ /BUFFER LINE (TYP.) LINE (TYP.) Ex. 10.0' No BUILD \ \\31 LINE (TYP.) 7 l mil \ \ Ill �� �-- \\ \\ �\ \ _�\ �l � / l \\\\\J \\' � ♦ ,� J / \ \ \ o \ dy di dJ -- ----- ------------------- -315------------- -------------------�------ ----- v------ -- � . -315-� POST -DEVELOPMENT FUTURE 100-YR-1- FLOODPLAIN 00-YRSFLOODPLAIN PER WARD CONSULTING ENGINEERING, PC ANALYSIS (TYP.) POST -DEVELOPMENT 100 -YR -1 FLOODPLAIN PER WARD CONSULTING _ - ENGINEERING, PC ANALYSIS (TYP.)L- EX. DI TOP= 315.66 INV (15")=312.55 «ii \'' EX. 60 RCP \j DAVIS DRIVE (SR -1969 - 150' PUBLIC R/W) PRE- DEVEL OPMEN T FLOOD WAY (TYP.) - ----------- FP - �-- x'315-----`- /---- NOTE: FP 100 -YR FLOODPLAIN ELEVATIONS ARE AS FOLLOWS: EAST SIDE OF ENTRANCE DRIVE: BFE=315.4' WEST SIDE OF ENTRANCE DRIVE: BFE=312.5' \ c r r SEAL A ISSUED FOR PERMIT 2019.04.05 REV.NO. I DESCRIPTIONS DATE REVISIONS SEAL CARO��ti, , \ �pEES L _ 028419 _= 4/05/2019 v�NFKIA4&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com - - REVISED FLOODWAY EX. PROPERTY BOUNDARY MCE PROJ. # EX. RIPARIAN BUFFER LINE DRAWN EX. 10.0' NO BUILD LINE - - - EX. EASEMENT LINE CHECKED EX. STREAM CENTERLINE PROJ. MGR. PROPOSED STORM DRAINAGE PIPE - - - EX. EASEMENT LINE EX. STORM DRAINAGE PIPE EFP EXISTING 100 -YR FLOODPLAIN FW EXISTING FLOODWAY EXISTING 100 -YR FLOODPLAIN �PW REVISED FLOODWAY EFFECTIVE FUTURE 100 -YR FLOODPLAIN POST PROJECT FUTURE 100 -YR FLOODPLAIN EX. CONTOUR LINE EXISTING RIPARIAN BUFFER AREA EXISTING 10.0' NO BUILDING AREA EXISTING FLOODPLAIN EXISTING FLOODWAY REVISED 100 -YR FLOODPLAIN EFFECTIVE FUTURE 100 -YR FLOODPLAIN • , POST -PROJECT FUTURE 100 -YR FLOODPLAIN 1 • \ \ \ POST -DEVELOPMENT 100 -YR \ \ FLOODPLAIN PER WARD CONSULTING \ I 1 Tq \ \ ENGINEERING, PC ANALYSIS (TYP.) +HP 31 B I POST -DEVELOPMENT FUTURE 100 -YR FLOODPLAIN PER WARD CONSULTING ENGINEERING, PC ANALYSIS (TYP.) EX. FLOOD HAZARD LINE (TYP.)PP 1E] 1 / \ PRE -DEVELOPMENT ✓ �\ \ \ \ \ ,- FLOOD WAY (TYP.) LIMITS OF DISTURBANCE (TYP.) - \ -37 / POST -DEVELOPMENT FLOOOWAY PER WARD CONSULTING ENGINEERING, PC ANALYSIS (TYP.) POST -DEVELOPMENT FLOODWAY PER WARD CONSULTING ENGINEERING, PC ANALYSIS (TYP.) lvi EX. 60" RCP 375 1S F y/ F� 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA FLOODPLAIN PLAN CALL N.C. ONE CALL CENTER BEFORE YOU DIG STOP I 1-800-632-4949 AVOID UTILITY NORTH DAMAGE 30' 0 30' 60' SCALE: 1"=30' (Horiz.) F -P CITY OF DURHAM PUBLIC WORKS DEPARTMENT APPROVED \ - ENGINEERING DATE STORM WATER DATE TRANSPORTATION DATE DATE DATE DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 DRAWN DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML SCALE M&C FILE NUMBER C2.0 HORIZONTAL: DRAWING NUMBER 1 "=30' VERTICAL: C2.0 N/A STATUS: REVISION NOT FOR CONSTRUCTION A ISSUED FOR REVIEW ONLY FOR REVIEW ONLY GENERAL NOTES: STAGE 1 CONSTRUCTION SEQUENCE: STAGE 1 CONSTRUCTION SEQUENCE (CONM EROSION CONTROL NOTES: 1. CENTERLINE OF 20.0 FOOT WIDE PUBLIC STORM WATER 1. THE INTENT OF THE CONSTRUCTION SEQUENCE IS TO PROVIDE THE 12. ONCE THE ARCH PIPE, POURED IN PLACE CONCRETE HEADWALL AND THE 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CITY OF DURHAM OR DURHAM COUNTY DRAINAGE EASEMENT. OWNERSHIP OF AND CONTRACTOR WITH A GENERAL GUIDE FOR CONSTRUCTION PURPOSES. THIS PRE -CAST CONCRETE JUNCTION BOX IS INSTALLED, THE CONTRACTOR IS TO REQUIREMENTS. RESPONSIBILITY FOR IMPROVEMENT AND MAINTENANCE OF SEQUENCE IS NOT INTENDED TO OUTLINE ALL CONSTRUCTION ACTIVITIES ON EXTEND THE EXISTING 60" RCP INTO THE JUNCTION BOX AS SHOWN AND STORM WATER FACILITIES IN THIS EASEMENT REMAINS THIS PROJECT. DETAILED IN THESE PLANS. 2. STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISH GRADE WITH VEGETATION, PAVING, WITH THE CURRENT OWNER. IF THE PROPERTY IS WITHIN 2 ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE DITCH LININGS, ETC. OR BECOMES A PART OF THE CITY, THE EASEMENT AND 13. BEFORE REMOVING THE TEMPROARY DIVERSION DITCH, PUMP AND COFFER WITH THE PROVISIONS OF THE DURHAM COUNTY UNIFIED DEVELOPMENT ACCESS POINTS TO THE EASEMENT ARE SUBJECT TO THE DAMS, THE CONTRACTOR IS TO CONTACT THE DURHAM COUNTY SEDIMENTATION LAND LEFT EXPOSED SHALL BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY GROUND TERMS AND RESTRICTIONS STATED IN THE "REVISED ORDINANCE REGULATING SEDIMENTATION AND EROSION CONTROL. AND EROSION CONTROL OFFICE FOR INSPECTION. COVER, DEVICES, OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION WITHIN THE APPLICABLE DECLARATION OF RIGHTS AND PRIVILEGES OF THE CITY 3. ALL EROSION CONTROL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER14TIME PERIOD AFTER ANY PHASE OF GRADING OR PERIOD OF INACTIVITY AS FOLLOWS: SEVEN OF DURHAM IN STORM WATER MANAGEMENT FACILITY RAINFALL EVENTS. NEEDED REPAIRS SHALL BE MADE IMMEDIATELY. . ONCE THE DURHAM COUNTY SEDIMENTATION AND EROSION CONTROL OFFICE (7) DAYS FOR A STEEP SLOPE; TEN (10) DAYS FOR A MODERATE SLOPE; 14 DAYS FOR LAND EASEMENTS" RECORDED IN REAL ESTATE BOOK 2298, AND ENGINEER HAS APPROVED, THE CONTRACTOR CAN REMOVE THE WITH NO SLOPE OR INCLINATION. FOR PURPOSES OF THIS SECTION, A MODERATE SLOPE PAGE 208, WHICH DOCUMENTS IS INCORPORATED HEREIN. 4. IF IT IS DETERMINED DURING CONSTRUCTION THAT SIGNIFICANT SEDIMENT IS TEMPROARY DIVERSION DITCH, PUMP AND COFFER DAMS. MEANS AN INCLINED AREA, THE INCLINATION OF WHICH IS LESS THAN OR EQUAL TO THREE THIS EASEMENT AND THE REVISED DECLARATION DO NOT LEAVING THE SITE, DESPITE PROPER IMPLEMENTATION AND MAINTENANCE, THE UNITS OF HORIZONTAL DISTANCE TO ONE UNIT OF VERTICAL DISTANCE; AND A STEEP SLOPE 15. CONTRACTOR IS TO EXTEND THE EXISTING 24" RCP AS SHOWN AND DETAILED CREATE THE OBLIGATION TO PROVIDE PUBLIC CONTRACTOR IS OBLIGATED TO TAKE ADDITIONAL CORRECTIVE ACTION. MEANS AN INCLINED AREA, THE INCLINATION OF WHICH IS GREATER THAN THREE UNITS OF IN THESE PLANS. HORIZONTAL DISTANCE TO ONE UNIT OF VERTICAL DISTANCE. NO OTHER CRITERIA APPLY. MAINTENANCE. NO BUILDING, FILLS, EMBANKMENTS OR CONTACT NCDEQ - LAND QUALITY SECTION, OWNER'S REPRESENTATIVE AND OBSTRUCTIONS PERMITTED WITHIN THE EASEMENT EXCEPT ENGINEER WITH ANY ADDITIONAL MEASURES NEEDED. 16. CONTRACTOR TO MAINTAIN ALL EROSION CONTROL MEASURES AT ALL TIMES. FOR ANY AREA OF LAND DISTURBING ACTIVITY WHERE GRADING ACTIVITIES HAVE BEEN ACCORDING TO THOSE TERMS." 5. CONTRACTOR SHALL ESTABLISH GROUNDCOVER ON DISTURBED AREAS WITHIN NEEDED REPAIRS SHALL BE MADE IMMEDIATELY. COMPLETED, TEMPORARY OR PERMANENT GROUND COVER SUFFICIENT TO RESTRAIN EROSION 2. 50.0 FOOT WIDE UNDISTURBED STREAM BUFFER EACH THE NUMBER OF CALENDAR DAYS AFTER COMPLETION OF GRADING PER THE 17. ONCE ALL THE PHASE 1 CONSTRUCTION HAS BEEN COMPLETED, THE SHALL BE PROVIDED AS SOON AS PRACTICABLE, BUT IN NO CASE LATER THAN SEVEN (7) SIDE OF STREAM, MEASURED FROM TOP OF BANK. NO SCHEDULE BELOW: CONTRACTOR IS TO CONTACT THE SEDIMENTATION AND EROSION CONTROL DAYS AFTER COMPLETION OF GRADING. CLEARING OR GRADING OTHER THAN SELECTIVE THINNING GRADUAL SLOPES: (14) CALENDAR DAYS OFFICE FOR APPROVAL BEFORE MOVING TO PHASE OF THE EROSION CONTROL 3. MAINTENANCE: ALL EROSION AND SEDIMENT CONTROL PRACTICES TO BE INSPECTED WEEKLY AND ORDINARY MAINTENANCE OF EXISTING VEGETATION MODERATE SLOPES: (10) CALENDAR DAYS (SHEET C3.1). PERMITTED. AND AFTER EVERY RUNOFF PRODUCING RAINFALL EVENT. NEEDED REPAIRS WILL BE MADE STEEP SLOPES: (7) CALENDAR DAYS IMMEDIATELY. 3. ALL DEVELOPMENT WITHIN THE FLOODWAY AND SLOPES ARE AS DEFINED IN THE PROVISIONS OF THE DURHAM COUNTY UNIFIED 4. TREE PROTECTION FENCE SHALL BE INSTALLED TO PROTECT EXISTING TREES OUTSIDE OF FLOODWAY FRINGE, INCLUDING FILL, NEW CONSTRUCTION, DEVELOPMENT ORDINANCE REGULATING SEDIMENTATION AND EROSION CONTROL. CONSTRUCTION LIMITS WHERE APPLICABLE. SUBSTANTIAL IMPROVEMENTS, MANUFACTURED HOUSING, STORAGE OF MATERIALS AND STORAGE OF TOXIC OR 6. SCHEDULE A PRE -CONSTRUCTION CONFERENCE WITH DURHAM COUNTY 5. ALL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CHECKED FOR STABILITY AND FLAMMABLE SUBSTANCES, IS PROHIBITED EXCEPT AS SEDIMENTATION AND EROSION CONTROL OFFICE (919) 560-7992. OPERATION FOLLOWING EVERY RUNOFF PRODUCING RAINFALL BUT IN NO CASE LESS THAN PROVIDED BY APPLICABLE FLOOD HAZARD REGULATIONS. ONCE EVERY WEEK. ANY NEEDED REPAIRS WILL BE MADE IMMEDIATELY TO MAINTAIN ALL 7. INSTALL TEMPORARY CONSTRUCTION ENTRANCE, CONCRETE WASHOUT AREA, PRACTICES AS DESIGNED. 4. "STATE AND FEDERAL PERMIT AUTHORIZATION MAY BE TREE PROTECTION FENCING AND TEMPROARY SILT FENCE AS SHOWN ON THE REQUIRED FROM THE DEHNR AND THE U.S. CORPS OF PLANS. 6. SEDIMENT WILL BE REMOVED FROM BEHIND THE SEDIMENT FENCE WHEN IT BECOMES ABOUT ENGINEERS PRIOR TO THE COMMENCEMENT OF ANY LAND 0.5 FEET DEEP AT THE FENCE. THE SEDIMENT FENCE WILL BE REPAIRED OR REPLACED AS DISTURBING ACTIVITIES IN OR NEAR A LAKE, STREAM, 8. CONTRACTOR IS TO INSTALL THE DIVERSION DITCH, PUMP, COFFER DAMS AND NECESSARY TO MAINTAIN A BARRIER. CREEK, TRIBUTARY OR ANY UNNAMED BODY OF WATER FILTER BAG AS SHOWN AND DETAILED IN THESE PLANS. AND ITS ADJACENT WETLANDS. 7. ALL AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED ACCORDING TO 5. 9. ONCE THESE DEVICES ARE INSTALLED AND THE STREAM IS REROUTED AROUND THE WORK AREA, THE CONTRACTOR IS TO INSTALL THE POUR IN PLACE SPECIFICATIONS IN THE VEGETATIVE PLAN TO MAINTAIN A VIGOROUS, DENSE VEGETATIVE 1 \ \�\\\� \ \\\ � CONCRETE HEADWALL AS SHOWN AND DETAILED IN THESE PLANS. COVER. 10. CONTRACTOR IS TO INSTALL THE PRECAST CONCRETE JUNCTION BOX AND THE 8. IF AN OFFSITE SOIL SPOIL OR BORROW SITE IS UTILIZED, THEN THE DISTURBED AREA FOR X\ \ ARCH PIPE AS SHOWN AND DETAILED IN THESE PLANS. THE SPOIL/BORROW SITE MUST BE INCLUDED IN THE LAND DISTURBANCE PLAN AND PERMIT \\\ X \ \ UNLESS THE SPOIL/BORROW SITE ALREADY HAS A LAND DISTURBANCE PERMIT. \\\X 11. CONTRACTOR IS TO COORDINATE ALL WORK WITH THE DURHAM COUNTY \ 1 \\\\\ \\\X \ SEDIMENTATION AND EROSION CONTROL OFFICE AS REQUIRED. 9. ALUMINUM PIPE ARCH CULVERT AND HEADWALL AND PRECAST STORM DRAIN JUNCTION BOX \\\N \ \1 TO BE MANUFACTURED BY CONTECH ENGINEERED SOLUTIONS, LLC OR APPROVED EQUAL. \\\N \ \ I 1 \ \ 1 I 10. PROPOSED LIMITS OF DISTURBANCE AREA = 1.15 ACRES. \\\\\ `�/\�_\\\\\\\\\ `� \11 O� O9\ / \ \\ \ \ \ \ 1 \ \ [/=\/ AI(1TCQ- O TEMPORARY CONSTRUCTION ENTRANCE. REFER TO SHEET D3.0. O TEMPORARY TREE PROTECTION FENCING. REFER TO SHEET D3.0. O3 TEMPORARY SILT FENCE. REFER TO SHEET D3.0. O4 SILT FENCE OUTLET. REFER TO SHEET D3.0. OCATCH BASIN INLET PROTECTION. REFER TO SHEET D3.1. O6 TEMPORARY DIVERSION DITCH (TYP.). REFER TO SHEET D3.0. O7 TEMPORARY ROCK CHECK DAM. REFER TO SHEET D3.1. O8 CONCRETE WASHOUT AREA. REFER TO SHEET D3.0. O9 EXISTING FES TO BE REMOVED AND EXISTING 24" RCP TO BE EXTENDED. REFER TO SHEET C3.1. 10 EXISTING 60" RCP TO BE EXTENDED. REFER TO SHEET C3.1. 11 COFFERDAM (TYP.). REFER TO SHEET D3.0. 12 CONTRACTOR SHALL PROVIDE PUMP TO BYPASS FLOWS AROUND WORK AREA. 13 FILTER BAG (TYP.). REFER TO SHEET D3.1. 14 CLASS B RIP RAP (TYP.). REFER TO SHEET D3.0. 15 ARC FILTER (TYP.). REFER TO SHEET D3.1. 16 TYPE III BARRICADE W/ SIDEWALK CLOSED SIGN. REFER TO SHEET D2.1. 17 EXISTING 60" RCP (TYP.). 18 9'-7" x 6'-6" ARCH PIPE (TYP.). REFER TO CONTECH DESIGN SHEET B2 THRU B5. 19 REINFORCED CONCRETE HEADWALL (TYP.). REFER TO SHEET D2.3. 20 REINFORCED CONCRETE JUNCTION BOX (TYP.). REFER TO SHEET D2.2. 21 EXTEND EXISTING 60" RCP (TYP.). \\\ \\ \ \ \ \ \ \ \ \ \ I I \ \ \ \ I \\ \ \\ \\ \ \ \ \ I - RIM=314.00 O \\ \\ \\ \\\ II I 312 �� IINV NV (15" NW -30975\ \ / \\ \ / 6' \ \ \ r �\ \� \\\v�\ \ EX. 10.0' NO BUILD \ \ \ I EX. FES INV (12" NE)=309.20 \\\ \ I LINE (TYP.) \ \ � I INV=306.24 INV < \ (TO BE REMOVED AND \ \ \ \\ \��\� \\\ \\\\I /D 24" RCP EXTENDED) \��\\\\� EX. 50.0' RIPARIAN \\\\ ,♦ O \ r� n \ \ \ \ \ \ \ \\ \ \\ - \ \ \ \ BUFFER LINE TYP. ♦ �"> > \ \ \ \ \ \\ \��\\ 4,0*1 4 70 375 \ \\ \\\\ \1 ARE -NC REGION NO. 14 LLC PIN: 0748-03-02-7196 DB 6902, PG 392-396 PB 11 PG 362-365 1,857,024 SF 42.63 ACRES 03 m 0 o _0a O� 3 15 \ I \ \ \ I IINV I U INW)=J I D.24 X 1LT FENCE 1 \ LIMITS OF DISTURBANCE (TYP.) 1 I 1 \ \ \ \ �I ✓/ '--306-// \ s, \ - - \ \ ✓_\ \/ SII II������\��\\�\ \ 4 '30� \ / / 111111°o\\�\\ \�\\ 3 EX. 100.0' SETBACK�\ EX. 100.0' SETBACK,Ln 14 -309 \ \ \ / ��� 11111111111111\ \ \� ��� 6\ 370\ 19 I v _ EX. FLOOD HAZARD V A \ \ - ( LINE (TYP.) `3�6 A \ \ EX. 50.0' RIPARIAN / \ 1 11A \ \ / \ �' X31 v V A BUFFER LINE (TYP.)�/ /--- \11�1 A L J 13� 18 LIMITS OF 21 � 1 \ \ \\ \ _ 3 \ ♦ \ 1 DISTURBANCE (TYP.) \\\\ \ \ \ 3� EX. 10.0' NO BUILD / \ LINE (TYP.)/ 2 \3/2\ \\\\ JO. \\ \_� \\\\/ ` \ 10 1\ ` \\ , / \\�� \\\\ \\�� �\ \\\ EX. PROPERTY LINE (TYP.) \ \ _ \\ _ / \\ \ \ \ EX. FLOODWAY S _ LINE (TYP.) 20 1 EX. 60" RCPa 7' 310----- -------- \\ \ - - - - Z ---- 310 -- -�- 0 0 - - �- - 3/3 ---- --- --_ ---- - �� _ z tEPs 311 L _� 3121 -------_ ----315----- -- ---- 313 12 P � ------- _ - - - - _ _ - - WALKING PATH - - - - - - - - 16 / ---------A ---315 MCKIM & CREED PNT #2 REBAR AND CAP SET - - - GRID COORDINATES _ N=782,097.36' - E=2,041,763.86' 7 (NAD 83/2011) ELEV.=315.23' i (NAVD88) v EX. DI TOP=315.66 i INV. (15")=312.55 SEAL A ISSUED FOR PERMIT 2019.04.05 REV.NO. DESCRIPTIONS DATE REVISIONS V E�� - SEAL CARO��ti, , L _ 028419 4/05/2019 Q �,9 FNGINEF-R 0��\� _ S9'28'37"W 625.58'(GROUND} - - - - - J , NPDES GROUNDCOVER STABILIZATION TIMEFRAMES CF=0.99992635 625.53'(GRID) = _ EP = 1 / / DAVIS DRIVE \ (SR -1999 - 150' PUBLIC R/W) i v� 1 v�NFKIN4&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com i EX. DI �31Si� TOP=314.18 INV. (15")=311.20 315 - - - - - - S -- - - - - - - - - - 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA EROSION CONTROL PLAN PHASE LEGEND: - - SITE AREA STABILIZATION TIMEFRAME DESCRIPTION EX. 10.0' NO BUILD LINE EXCEPTIONS PERIMETER DIKES, 7 DAYS NONE SWALES, DITCHES, EX. EASEMENT LINE SLOPES EFIP EX. FLOOPLAIN HIGH QUALITY WATER 7 DAYS NONE (HQW) ZONES EFP EXISTING 100 -YR FLOODPLAIN SLOPES STEEPER 7 DAYS 14 DAYS FOR SLOPES THAN 3:1 -FW I 10' OR LESS IN FP EFFECTIVE FUTURE 100 -YR FLOODPLAIN LENGTH AND NOT POST PROJECT FUTURE 100 -YR FLOODPLAIN STEEPER THAN 2:1 SLOPES 3:1 OR 14 DAYS 7 DAYS FOR SLOPES FLATTER loor GREATER THAN 50' IN ARC FILTER OUTLET PROTECTION LENGTH ALL OTHER AREAS 14 DAYS NONE, EXCEPT FOR WITH SLOPES FLATTER PERIMETERS AND HQW THAN 4:1 RIPRAP PROTECTION ZONES _ S9'28'37"W 625.58'(GROUND} - - - - - J , NPDES GROUNDCOVER STABILIZATION TIMEFRAMES CF=0.99992635 625.53'(GRID) = _ EP = 1 / / DAVIS DRIVE \ (SR -1999 - 150' PUBLIC R/W) i v� 1 v�NFKIN4&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com i EX. DI �31Si� TOP=314.18 INV. (15")=311.20 315 - - - - - - S -- - - - - - - - - - 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA EROSION CONTROL PLAN PHASE LEGEND: - - EX. PROPERTY BOUNDARY MCE PROJ. # EX. RIPARIAN BUFFER LINE DRAWN EX. 10.0' NO BUILD LINE - - - EX. EASEMENT LINE CHECKED EX. STREAM CENTERLINE - - - EX. EASEMENT LINE EX. STORM DRAINAGE PIPE EFIP EX. FLOOPLAIN FW EX. FLOODWAY FP EX. EASEMENT LINE EFP EXISTING 100 -YR FLOODPLAIN FW EXISTING FLOODWAY FP EXISTING 100 -YR FLOODPLAIN -FW I REVISED FLOODWAY FP EFFECTIVE FUTURE 100 -YR FLOODPLAIN POST PROJECT FUTURE 100 -YR FLOODPLAIN TREE PROTECTION FENCE SF TEMPORARY SITE FENCE TEMPORARY DIVERSION DITCH loor ARC FILTER OUTLET PROTECTION INLET PROTECTION EX. CONTOUR LINE ® PUMP AROUND SILT FENCE OUTLET RIPRAP PROTECTION ® CONCRETE WASHOUT CALL N.C. ONE CALL CENTER BEFORE YOU DIG STOP 1-800-632-4949 AVOID UTILITY NORTH DAMAGE 30' 0 30' 60' MEN SCALE: 1"=30' (Horiz.) CITY OF DURHAM PUBLIC WORKS DEPARTMENT APPROVED ENGINEERING DATE STORM WATER DATE TRANSPORTATION DATE DATE DATE DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 DRAWN DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML SCALE M&C FILE NUMBER C3.0 HORIZONTAL: DRAWING NUMBER 1 "=30' VERTICAL: C3.0 N/A STATUS: REVISION NOT FOR CONSTRUCTION A ISSUED FOR REVIEW ONLY GENERAL NOTES: GENERAL NOTES: SELF INSPECTION NOTICE: 1. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE 10. CONTRACTOR IS RESPONSIBLE FOR ADHERING TO ALL PERMIT NOTIFICATION OF LAND RESOURCES SEDIMENT AND EROSION CONTROL 7 DAYS FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. AND ABOVE GROUND, ARE BASED ON BEST AVAILABLE RECORD CONDITIONS, MONITORING AND REPORTING REQUIREMENTS. SELF -INSPECTION PROGRAM: DRAWINGS. CONTRACTOR SHALL NOTIFY OWNER IF ANY DISCREPANCIES EXIST 6. SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES THE SEDIMENTATION POLLUTION CONTROL ACT WAS AMENDED IN 2006 TO NONE PRIOR TO CONSTRUCTION. NO ADDITIONAL COMPENSATION WILL BE 11. GRADED SLOPES SHALL BE STABILIZED WITH CURLEX SINGLE NET REQUIRE THAT PERSONS RESPONSIBLE FOR LAND -DISTURBING ACTIVITIES 7 DAYS PAID TO CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS THESE SOILS SHALL BE COMPACTED TO THE STANDARD PROCTOR (CURLEX 1) MATTING BY AMERICAN EXCELSIOR COMPANY OR INSPECT A PROJECT AFTER EACH STAGE OF THE PROJECT TO MAKE SURE MAXIMUM DRY DENSITY UNLESS OTHERWISE RECOMMENDED BY THE OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH LENGTH AND NOT APPROVED EQUAL. THAT THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN IS BEING STEEPER THAN 2:1 NOTIFICATION HAS NOT BEEN GIVEN. LIMITS OF DISTURBANCE NOTES: 7. FOLLOWED. RULES DETAILING THE DOCUMENTATION OF THESE INSPECTIONS EXISTING FES TO BE REMOVED AND EXISTING 24" RCP TO BE GREATER THAN 50' IN 12. NO PORTION OF THIS PROPERTY IS LOCATED IN SPECIAL FLOOD TOOK EFFECT OCTOBER 1, 2010. THE SELF -INSPECTION PROGRAM IS 2. CONTRACTOR SHALL NOTIFY "NORTH CAROLINA ONE CALL AT NONE, EXCEPT FOR HAZARD AREA "AE" AS SHOWN ON FEMA FIRM MAP #3710963400J SEPARATE FROM THE WEEKLY SELF-MONITORING PROGRAM OF THE NPDES 8. 1-800-632-4949 AT LEAST 48 HOURS PRIOR TO BEGINNING 2. SILT FENCE AND TREE PROTECTION FENCE LINES ALSO DELINEATE DATED SEPTEMBER 6, 2006. STORMWATER PERMIT FOR CONSTRUCTION ACTIVITIES. THE FOCUS OF THE THE LIMITS OF DISTURBANCE. ALL SILT FENCING OR TREE CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES DURING CONSTRUCTION. PROTECTION FENCING SHALL BE INSTALLED INSIDE LIMITS OF SELF -INSPECTION REPORT IS THE INSTALLATION AND MAINTENANCE OF 15 LOCATED. CONTRACTOR TO CONTACT ANY LOCAL UTILITIES THAT 13. BEFORE STARTING ANY CONSTRUCTION OF IMPROVEMENTS WITHIN EROSION AND SEDIMENTATION CONTROL MEASURES ACCORDING TO THE PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NORTH SHEET D2.1. ANY NCDOT STREET OR HIGHWAY RIGHT-OF-WAY, CONTACT NCDOT APPROVED PLAN. THE INSPECTIONS MUST BE CONDUCTED AFTER EACH 60" REINFORCED CONCRETE PIPE (TYP.). CAROLINA ONE CALL". 18 DISTRICT OFFICE AND OBTAIN ALL PERMITS AND ENCROACHMENTS STAGE OF THE PROJECT, AND CONTINUED UNTIL PERMANENT GROUND COVER I DESIGN SHEETS B2 THRU B5. \ AND KEEP COPIES ON CONSTRUCTION SITE AT ALL TIMES. ALSO IS ESTABLISHED IN ACCORDANCE WITH NCGS 113A-54.1 AND 15A NCAC 3. OVERHEAD ELECTRIC LINES MAY EXIST ON THE SITE. CONTRACTOR REINFORCED CONCRETE HEADWALL (TYP.). REFER TO SHEET CONTACT NCDOT DISTRICT OFFICE 24 HOURS IN ADVANCE BEFORE 46.0131. THE SELF -INSPECTION REPORT FORM IS AVAILABLE AS AN EXCEL D2.3. SHALL CONTACT DUKE POWER AT 1-800-452-2777 PRIOR TO 20 PLACING CURB AND GUTTER AT (910) 944-7621. SPREADSHEET FROM COMMENCING ANY ACTIVITY WITHIN 200 -FT OF DUKE POWER RIGHT \ HTTP: //WWW.DLR.ENR.STATE.NC.US /PAGES /SEDIMENTATION_ NEW.HTML. IF \ OF WAY. 24" REINFORCED CONCRETE PIPE (TYP.). \ YOU HAVE QUESTIONS OR CANNOT ACCESS THE FORM, PLEASE CONTACT 15" REINFORCED CONCRETE PIPE (TYP.). 23 15" ALUMINUM PIPE (TYP.). THIS OFFICE AT (919) 791-4200. 4. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL ARRANGE AND NPDES GROUNDCOVER STABILIZATION TIMEFRAMES ATTEND A PRECONSTRUCTION CONFERENCE WITH NCDEQ, OWNER STABILIZATION TIMEFRAME AND ENGINEER. TEMPORARY CONSTRUCTION ENTRANCE. REFER TO SHEET 5. EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND 7 DAYS NONE AND ABOVE GROUND, ARE BASED ON BEST AVAILABLE RECORD TEMPORARY TREE PROTECTION FENCING. REFER TO SHEET DRAWINGS. D3.0. 6. SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES 7 DAYS NONE GREATER THAN 3:1 (H: V) SHALL BE APPROVED, PLACED AND SILT FENCE OUTLET. REFER TO SHEET D3.0. COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. 7 DAYS 14 DAYS FOR SLOPES THESE SOILS SHALL BE COMPACTED TO THE STANDARD PROCTOR BLOCK AND GRAVEL STONE INLET PROTECTION. REFER TO 10' OR LESS IN MAXIMUM DRY DENSITY UNLESS OTHERWISE RECOMMENDED BY THE SHEET D3.0. LENGTH AND NOT GEOTECHNICAL ENGINEER. TEMPORARY ROCK CHECK DAM. REFER TO SHEET D3.0. STEEPER THAN 2:1 SLOPES 3:1 OR LIMITS OF DISTURBANCE NOTES: 7. ALL GRADED AREAS SHALL BE SLOPED SUCH THAT NO AREAS OF EXISTING FES TO BE REMOVED AND EXISTING 24" RCP TO BE GREATER THAN 50' IN STANDING WATER OCCUR AND ALL AREAS POSITIVELY DRAIN TO 1. LIMITS OF DISTURBANCE LINES ARE CLEARING LIMIT LINES WHICH LENGTH DRAINAGE STRUCTURES, SWALES OR STORMWATER MANAGEMENT WILL BE FLAGGED FOR A MINIMUM OF ONE PER 50 -FT OR CLOSER NONE, EXCEPT FOR FACILITIES. DEPENDING ON VISIBILITY. 8. CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL PROPERTY 2. SILT FENCE AND TREE PROTECTION FENCE LINES ALSO DELINEATE ZONES CORNERS AND SHALL REPLACE ALL MARKERS REMOVED IF DAMAGED THE LIMITS OF DISTURBANCE. ALL SILT FENCING OR TREE \ DURING CONSTRUCTION. PROTECTION FENCING SHALL BE INSTALLED INSIDE LIMITS OF \ 15 DISTURBANCE. 9. CONTRACTOR IS RESPONSIBLE FOR ALL DEWATERING AS NECESSARY TYPE III BARRICADE W/ SIDEWALK CLOSED SIGN. REFER TO NPDES GROUNDCOVER STABILIZATION TIMEFRAMES SITE AREA STABILIZATION TIMEFRAME DESCRIPTION TEMPORARY CONSTRUCTION ENTRANCE. REFER TO SHEET EXCEPTIONS PERIMETER DIKES, 7 DAYS NONE SWALES, DITCHES, TEMPORARY TREE PROTECTION FENCING. REFER TO SHEET SLOPES D3.0. TREE PROTECTION FENCE HIGH QUALITY WATER 7 DAYS NONE (HQW) ZONES SILT FENCE OUTLET. REFER TO SHEET D3.0. SLOPES STEEPER 7 DAYS 14 DAYS FOR SLOPES THAN 3:1 BLOCK AND GRAVEL STONE INLET PROTECTION. REFER TO 10' OR LESS IN SHEET D3.0. LENGTH AND NOT O7 TEMPORARY ROCK CHECK DAM. REFER TO SHEET D3.0. STEEPER THAN 2:1 SLOPES 3:1 OR 14 DAYS 7 DAYS FOR SLOPES FLATTER EXISTING FES TO BE REMOVED AND EXISTING 24" RCP TO BE GREATER THAN 50' IN EXTENDED. REFER TO SHEET C3.0. LENGTH ALL OTHER AREAS 14 DAYS NONE, EXCEPT FOR WITH SLOPES FLATTER COFFERDAM (TYP.). REFER TO SHEET D3.0. PERIMETERS AND HQW THAN 4:1 CONTRACTOR SHALL PROVIDE PUMP TO BYPASS FLOWS AROUND WORK AREA. ZONES THROUGHOUT CONSTRUCTION. 3. ADDITIONAL DISTURBED AREA: 1.15 ACRES I 1 \ \W\\\\\ V 1 \ 1 \ \ \ \\\\ \\\ \ 1 IV N �� ♦ \ \ ♦ \1 X N \\ ♦ 11 ����\ \\\\\\\\\ \\ \\ \\ \tel \ \ ♦ /� \ \ \\ \\\��\\� \� ♦ `o \\ \ \ \ \� 09 \ \ \ \ II i� \\ \ I / \�\\\ \\\ \\ \ \ \ \ \ \ I \ \ ♦ \ / \\\ \\ ♦ \ i \ \ \ \ I / \\�A�\� \ \ \ \\\\\\ ♦ \ \ 4 41111 I / /\\\ / \\ \\\� ���\�\\ / HW -NO 2 EL. = 305.50 306-� \ \ \�\\\\ RIPRAP ���� ♦ - -\\ \ \\\\\ X' LxX'WxXX" D CLASS x � 4 II\00 \� \ �� 19 \\ -309\ \ \ \ / ♦ �` II\1111III(((I\ \ \\ jI 370 \ \ \ \ / / 1,111111\ II II l\ \ 4 CLASS 1 RIPRAP KEYED IN ALONG SIDE SLOPES (TYP.) , RIPRAP PLUNGE POOL , _ 20' L x 18' W x 1.5' D ��0 / \ LINED WITH NCDOT CLASS 1 ` - \ _ - \\\ RIPRAP PLACED AT 24" DEPTH - - _ - REINFORCED CONCRETE HEADWALL NO. 1� INV EL.=300.00 -__ �_ 4 (REFER TO SHEET D2.1 & D2.2) X14- - -��--- - 3 - - -i=- - l _ _ INV --------- ----315-----_ - - -- � / --------�------------- -- -- -- ---------_----- - -315 ----_ ----- T_ CI A ISSUED FOR PERMIT REV.NO. �pEES L 028419 _= 4/05/2019 %��q� FNGINEF,R 4:::)�\; STAGE 2 CONSTRUCTION SEQUENCE: 1. CONTRACTOR IS TO RECIEVE APRPOVAL FROM THE SEDIMENTATION AND EROSION CONTROL OFFICE BEFORE MOVING TO PHASE 2 OF EROSION CONTROL. 2. CONTRACTOR TO MINIMIZE ENCROACHMENT INTO THE STREAM BUFFER AND FLOODWAY PER THE APPROVED PLANS. 3. STABILIZE THE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION OR PAVING. 4. CONTRACTOR IS TO COMPLETE BACKFILLING AND START ROADWAY INSTALLATION. 5. CONTRACTOR IS TO INSTALL THE ROADWAY DRAINAGE SYSTEM, CURB AND GUTTER, CONCRETE SIDEWALKS AND ASPHALT GREENWAY AS SHOWN AND DETAILED IN THESE PLANS. 6. CONTRACTOR TO PROVIDE PEDESTRIAN SIGNAGE AS SHOWN AND DETAILED IN THESE PLANS. 7. INSTALLATION OF THE ROADWAY SUBBASE AND STABILIZATION OF SLOPES ARE TO CONTINUE. 8. ONCE THE ROADWAY HAS BEEN BROUGHT UP TO SUBGRADE THE CONTRACTOR IS TO COORDINATE FINAL PAVING WITHT THE OWNER AND ENGINEER. 9. WHEN CONSTRUCTION IS COMPLETE AND ALL AREAS ARE STABILIZED COMPLETELY, THE CONTRACTOR IS TO CALL THE SEDIMENTATIONA AND EROSION CONTROL OFFICE (919) 560-7992 FOR INSPECTION AND FINAL APPROVAL TO REMOVE TEMPORARY EROSION CONTROL MEASURES. 10. IF SITE IS APPROVED, REMOVE THE TEMPORARY SILT FENCING AND SEED AND MULCH ANY RESULTING BARE AREAS. 11. WHEN VEGETATION HAS BECOME ESTABLISHED, CALL FOR FINAL SITE INSPECTION BY DURHAM COUNTY SEDIMENTATION AND EROSION CONTROL OFFICE PERSONNEL 12. OBTAIN CERTIFICATE OF COMPLETION FROM THE DURHAM COUNTY SEDIMENTATION AND EORSION CONTROL OFFICE. _----__-------- m m m m m m / / / DAVIS DRIVE (SR -1999 - 150' PUBLIC R/W) v v &CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com EROSION CONTROL NOTES: 1. ADDITIONAL SEDIMENT AND EROSION CONTROL MEASURES MAY NEED TO BE INSTALLED IF DEEMED NECESSARY BY EITHER THE ENGINEER OR ENVIRONMENTAL INSPECTOR. 2. ESTABLISH GROUNDCOVER ON GRADED SLOPES AND FILLS WITHIN 14 CALENDAR DAYS AFTER COMPLETION OF ANY GRADING PHASE. 3. TEMPORARY SEDIMENT CONTROL MEASURES (SILT FENCE, DIVERSION DITCHES, CONSTRUCTION ENTRANCE, ETC.) SHALL BE MAINTAINED UNTIL ALL CONTRIBUTING AREAS ARE GRADED AND STABILIZED. 4 DUST CONTROL ON SITE SHALL BE MINIMIZED BY SPRAYING WATER ON DRY AREAS OF THE SITE. THE USE OF OILS AND OTHER PETROLEUM BASED OR TOXIC LIQUIDS FOR DUST SUPPRESSION IS STRICTLY PROHIBITED. 5. IF THE MAJORITY OF MUD OR DIRT IS NOT REMOVED FROM CONSTRUCTION TRAFFIC BY CONSTRUCTION ENTRANCES, CONTRACTOR SHALL CONSTRUCT VEHICLE WASH AREAS AT CONSTRUCTION TRAFFIC EXIT POINTS. MUD AND DIRT SHALL BE INTERCEPTED AND TRAPPED BEFORE WASH WATER IS ALLOWED TO BE DISCHARGED OFFSITE. RINSE -OFF WILL NOT BE ALLOWED OUTSIDE THE PROJECT CONSTRUCTION LIMITS. 6. SEDIMENT SHALL BE REMOVED FROM BEHIND THE SILT FENCE WHEN IT REACHES 4 -INCHES IN DEEP. 7. REFER TO SHEETS D3.1, D3.2 & D3.3 FOR EROSION CONTROL DETAILS. 8. CONTRACTOR SHALL SEEK PERMIT FOR ANY BORROW AND/OR SPOIL AREAS NOT SHOWN ON THESE PLANS. 9. CONTRACTOR IS TO MAINTAIN ALL TEMPORARY EROSION CONTROL MEASURES THROUGHOUT CONSTRUCTION. CONTRACTOR SHALL COORDINATE WITH DURHAM COUNTY EROSION CONTROL INSPECTOR. I I L� \ \ \ L L �/ O v \ 1 \\ \ \ 1 11 I ----� \ 1 EX. EASEMENT LINE KEY NOTES: EXISTING 100 -YR FLOODPLAIN O TEMPORARY CONSTRUCTION ENTRANCE. REFER TO SHEET FP EXISTING 100 -YR FLOODPLAIN D3.0. REVISED FLOODWAY O2 TEMPORARY TREE PROTECTION FENCING. REFER TO SHEET POST PROJECT FUTURE 100 -YR FL00 D3.0. TREE PROTECTION FENCE O3 TEMPORARY SILT FENCE. REFER TO SHEET D3.0. %am# O4 SILT FENCE OUTLET. REFER TO SHEET D3.0. O CATCH BASIN INLET PROTECTION. REFER TO SHEET D3.0. O6 BLOCK AND GRAVEL STONE INLET PROTECTION. REFER TO 60' SHEET D3.0. • • • O7 TEMPORARY ROCK CHECK DAM. REFER TO SHEET D3.0. Og CONCRETE WASHOUT AREA. REFER TO SHEET D3.0. O9 EXISTING FES TO BE REMOVED AND EXISTING 24" RCP TO BE EXTENDED. REFER TO SHEET C3.0. 10 EXISTING 60" RCP TO BE EXTENDED. REFER TO SHEET C3.0. 11 COFFERDAM (TYP.). REFER TO SHEET D3.0. \ 12 CONTRACTOR SHALL PROVIDE PUMP TO BYPASS FLOWS AROUND WORK AREA. 13 NCDOT CURB INLET (TYP.). REFER TO SHEET D2.1. \ 14 CLASS B RIP RAP (TYP.). REFER TO SHEET D3.0. \ 15 ARC FILTER (TYP.). REFER TO SHEET D3.1 \ 16 TYPE III BARRICADE W/ SIDEWALK CLOSED SIGN. REFER TO SHEET D2.1. 17 60" REINFORCED CONCRETE PIPE (TYP.). 18 9'-7" x 6'-6" ARCH PIPE (TYP.). REFER TO CONTECH I DESIGN SHEETS B2 THRU B5. \ PERMANENT SWALE #3 �� ��v ��� \V �_ 19 REINFORCED CONCRETE HEADWALL (TYP.). REFER TO SHEET \ ��� D2.3. \ 20 REINFORCED CONCRETE JUNCTION BOX (TYP.). REFER TO SHEET D2.2. \ \ \ \ 21 24" REINFORCED CONCRETE PIPE (TYP.). \ 22 15" REINFORCED CONCRETE PIPE (TYP.). 23 15" ALUMINUM PIPE (TYP.). INV OUT=305.70 , \ 1 All 3 AdL ���i•1• --- - ::37"A25.58'(GROUND) CF=0.99992635 625.53'(GRID) i 3151 FP EX. EASEMENT LINE EFP EXISTING 100 -YR FLOODPLAIN FW EXISTING FLOODWAY FP EXISTING 100 -YR FLOODPLAIN CHECKED REVISED FLOODWAY FP EFFECTIVE FUTURE 100 -YR FLOODPLA POST PROJECT FUTURE 100 -YR FL00 TREE PROTECTION FENCE -SF TEMPORARY SITE FENCE %am# ARC FILTER OUTLET PROTECTION 40% % INLET PROTECTION EX. CONTOUR LINE ® 60' SILT FENCE OUTLET • • • TEMPORARY BARRICADE 3 I PERMANENT SWALE #3 �� ��v ��� \V �_ \V +HP LINED W/ STRAW W/NET ��� ---/ / ._-\ ,��-�-�� �_ 3i 11. \ \ \ \ \ PERMANENT SWALE #1 \ LINED W/ STRAW W/NET �� \\ \\ LEGEND: \ EX. PROPERTY BOUNDARY PERMANENT SWALE #2 \ \ LINED W/ STRAW W/NET \ � \ � � EX. RIPARIAN BUFFER LINE \37 \ \ -376S�� EX. 10.0' NO BUILD LINE 7 \ - - - EX. EASEMENT LINE PERMANENT SWALE #4 \ - - EX. STREAM CENTERLINE LINED W/ STRAW W/NET � - - - EX. EASEMENT LINE - EX. STORM DRAINAGE PIPE DI -48 \ EFP EX. FLOOPLAIN RIM=308.70 \ � � � Q � � � FW EX. FLOODWAY INV OUT=305.70 , \ 1 All 3 AdL ���i•1• --- - ::37"A25.58'(GROUND) CF=0.99992635 625.53'(GRID) i 3151 FP EX. EASEMENT LINE EFP EXISTING 100 -YR FLOODPLAIN FW EXISTING FLOODWAY FP EXISTING 100 -YR FLOODPLAIN CHECKED REVISED FLOODWAY FP EFFECTIVE FUTURE 100 -YR FLOODPLA POST PROJECT FUTURE 100 -YR FL00 TREE PROTECTION FENCE -SF TEMPORARY SITE FENCE %am# ARC FILTER OUTLET PROTECTION 40% % INLET PROTECTION EX. CONTOUR LINE ® PUMP AROUND SILT FENCE OUTLET • • • TEMPORARY BARRICADE 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA GRADING, DRAINAGE PLAN & EROSION PHASE 2 PLAN CALL N.C. ONE CALL CENTER BEFORE YOU DIG STOP 1-800-632-4949 AVOID UTILITY NORTH DAMAGE / 30' 0 30' 60' SCALE: 1"=30' (Horiz.) CITY OF DURHAM PUBLIC WORKS DEPARTMENT APPROVED ENGINEERING DATE STORMWATER DATE TRANSPORTATION DATE DATE DATE DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 DRAWN DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML SCALE HORIZONTAL: 1 "=30' VERTICAL: N/A M&C FILE NUMBER C3.1 DRAWING NUMBER C3.1 STATUS: REVISION NOT FOR CONSTRUCTION A ISSUED FOR REVIEW ONLY G� O 16 X01. PYTPKIn PYICTIKIr Rh" PrP EX. 10.0' NO BUILD LINE (TYP.) 194 REINFORCED CONCRETE JUNCTION BOX (REF TO DETAIL SHEET D2.1) 9'-7" X 6-6" CULVERT PLAN (STA. 10+00.00 TO 11+86.72) SCALE = 1" = 30' / EX. 10.0' NO BUILD / LINE (TTP.) / EX. 50.0' RIPARIAN / BUFFER LINE (TYP.) own ,www REINFORCED CONCRETE HEADWALL NO. 1 (REF TO SHEET D2.2) 9'-7" X 6'-6" CULVERT PIPE (REF TO DETAIL SHEET D2.1) / 24" R \ _%C� \/\i i HW NO. 2 INV OUT=XXX.XX i 174 SEAL A ISSUED FOR PERMIT 2019.04.05 REV.NO. DESCRIPTIONS DATE REVISIONS 9+60 10+00 10+40 10+80 11+20 11+60 9'-7" X 6-6" CULVERT PLAN & PROFILE SCALE = (Horiz.) 1" = 30'; (Vert.) 1" = 3' SEAL ` �pEESp L - 028419 4/05/2019 Q u �l\\,��`` v v &CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com 12+00 12+40 12+8013+00 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA 9'-T x 6-6" CULVERT PLAN & PROFILE CALL N.C. ONE CALL CENTER BEFORE YOU DIG 0%0 1 STOP 1-800-632-4949 AVOID UTILITY NORTH DAMAGE / 30' 0 30' 60' SCALE: 1"=30' (Horiz.) CITY OF DURHAM PUBLIC WORKS DEPARTMENT APPROVED ENGINEERING DATE STORM WATER DATE TRANSPORTATION DATE DATE DATE DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 DRAWN DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML 321 321 REINFORCED CONCRETE JUNCTION BOX (SEE DETAIL SHEET D2.1) 318 318 4.0'0 MANH LE PROPOSED EL. =314.85 GRADE 315 315 77 LF 9'-7" X 6'-6" OBLONG CULVERT Com? 0.8% 312 312 EXTENDED 6, RCP REINFORCED CONCRETE HEADWALL NO. 1 (REFER TO DETAIL SHEET D2.3) 309 - - I I 309 I I EX. 6p" CMP 306 CUL VEfi T ®1.09 I I 306 INV EL 300.00 / I I 303 303 EX. 60" RCP I I INV EL. 303.89 1 1 z INV EL. 303.78 1z 300 \ 300 IN V EL. 300.62 EXISTING GRADE 297 297 IPRAP PLUNGE OOL 20' L x 18' W 1.5'D LINED WTIH NCDOT CLASS 1 RIPRAP P ACED AT 24" DEPTH 294 294 O O N NCID SOD �� r-00 00 -tO) (D N —O) r �0) C)00 �N N 4 2 N O 4 004 O 4 O 0 O0; 0 C) M 0 M 0 M M M M SEAL A ISSUED FOR PERMIT 2019.04.05 REV.NO. DESCRIPTIONS DATE REVISIONS 9+60 10+00 10+40 10+80 11+20 11+60 9'-7" X 6-6" CULVERT PLAN & PROFILE SCALE = (Horiz.) 1" = 30'; (Vert.) 1" = 3' SEAL ` �pEESp L - 028419 4/05/2019 Q u �l\\,��`` v v &CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com 12+00 12+40 12+8013+00 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA 9'-T x 6-6" CULVERT PLAN & PROFILE CALL N.C. ONE CALL CENTER BEFORE YOU DIG 0%0 1 STOP 1-800-632-4949 AVOID UTILITY NORTH DAMAGE / 30' 0 30' 60' SCALE: 1"=30' (Horiz.) CITY OF DURHAM PUBLIC WORKS DEPARTMENT APPROVED ENGINEERING DATE STORM WATER DATE TRANSPORTATION DATE DATE DATE DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 DRAWN DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML SCALE M&C FILE NUMBER C3.1 HORIZONTAL: DRAWING NUMBER 1 "=30' VERTICAL: C3.2 1"=3' STATUS: REVISION NOTF R CONSTRUCTION A ISSUED FOR REVIEW ONLY 9" 5" , 6" I 24" 1 •4 N r 3YR 4 i ,n m 3.R 1 3/4"R iv • 3/4'R I /8..R N - • a 1 %$-R 18" (NCDOT STD } tf 30" (NCDDT STD.) r- I 18" MOUNTABLE CURB + GUTTER 30" CURB + GUTTER �I �- g 13 $/2"R 1/2"R� 18"iR 6 1/2" 3" R 3•' R4 o N z71�R ff i 24- (NCDOT STD.) 24" ROLLED CURB + GUTTER 24" CURB f CUTTER MATCH SLOPE OF 3.. 12 ROAD SECTION 1/8"R TIz R� f 112- 1/2"/5T. z F 7-777. - S j 30" VALLEY GUTTER 24" SHOULDER CURB } T!, , � - 36- OR 48" j 36' OR 43" VALLEY GUTTER DURHAM 5' MAX City of Durham, NC 10i Ci Hall PPaza v 101 City Voice i9t9)560A326 .0 ` - Durham, N.C. 27701 _ . -F,E STTANOARD SPEURCAI IONS ONLY IVww.durhamnc_gov Verce(919)560-4326 .4 ® CONCRETE CURB NotTa5GaIe x40247 CONCRETE BASE DIAMETER 8% EXPANSION JOINT REViON e: o.s°R ro r.aa"R I� AND GUTTER June, 201-1 ne, 2017 1 of S d 2 121 5' MAX 9 C C r: .0 ` - ,D a 0 0 0 www.durhamnc.gov Verce(919)560-4326 .4 ® CONCRETE CURB Nei Tora Scale 3 s 0 .: CONCRETE BASE DIAMETER 8% EXPANSION JOINT Ream, DATE 1 0 0 0 a o.s°R ro r.aa"R I� AND GUTTER $ffivvavvv�o<vvr: 2 2 T P IAM T R z SIDEWALKS 10) 0 0 0 0 OF NO HAN 50% TTO THAN 0000 , nnr'n00 +c _� a d' c N4 OSE 65% • z - v 4 Z '{ a • z o a _ e 0 00 OF THE BASE DIAMETER 0 0 0 0 a 0 -65 --MIN. o 6.9•' TO 1.4" r f' 1.6. TO 2.4 < L,W .a ' Ti J2 -K 1 T %4 "H V C-�00 ' + 45 ' 0, U c 'Fl S,12) 4' MINIMUM RAMP WIDTH 5EE NOTE 1 4' MINIMUM RAMP WIDTH SEE NOTE 1 CONCRETE BLOCKS CLAY OR CONCRETE BRICKS MINIMUM (36) BRICKS MINIMUM (8) BLOCKS OF 512E OF SIZE 4"W x 8"L x 2 1/4"H 12"W x 12% x 2"H NOTES= 1- DLtectoble warning dames will rover 2'-13" length and folk width of the ramp floor as shown on the details, 2. Detectable warning dames will contrast visibility with adjoining surface, either light -on -dark, or dark -on -light sequence covering the entire ramp. 3. Portland cement / sand mix 50% by weight sand. Install as dry mix. Hand tamp for compaction and level before setting bricks. 4. Bricks should be butted as close together as allows. Sweep Portland cement / sand mix into remaining cracks. DURHAM blicWarks City of Durham, NC Voice [919}560 326 101 C 701 Citytyt. uF Hall Pfaza Durham, N.C. 2-1-101 USE WITH THE STANDARD SPECIFICATIONS ONLY www.durharim-gay DETECTABLE To ��""" Nos To Scale 2 405.09 WARNING DOMES REVISION DATE SHEETA uiFw I>ioM ,Iona, 2017 1 1 of 2 SEE SHEET 1 OF 2 FOR CURB + TYPE / DIME a� 4" COMPACTED A.B.C. UNDER ALL CURB + GUTTER TCP OF CURB HOT APPLIED JOINT SEALER 1 /2"� �� AFTER REMOVAL OF 3 /S" RADIUS 1/2"-3/4" OF EXPANSION JOINT MATERIAL 1/8" RADIUS SURFACE of GUTTER .' 1,{ +EXPANSfON JOINT' TRANSVERSE EXPANSION JOINT IN CURB AND GUTTER NOTES= Use non --reinforced, air entrained, concrete with a minimum strength of 3000 lbs. 2, Contraction joints shall be placed at 10' intervals. 3. Contraction joints may be installed by the use of templates or formed by other approved methods. Where such joints are not formed by templates, a minimum depth of 1 1/2" shall be obtained, 4- All construction joints shall be filled with joint filler and hot applied joint sealer. See NCDOT specifications, 5. Expansion joints shall be spaced at 90' intervals, and adjacent to all rigid objects DURHAM 5' MAX 9 C C r: .0 ` - Durham, N.C. 27701 uSE W.TH THE STANDARD SPEC:.RCATION5 ONLY www.durhamnc.gov Verce(919)560-4326 z CONCRETE CURB Nei Tora Scale 3 s 0 .: CONCRETE • EXPANSION JOINT Ream, DATE 51tEET a. 1 8 8 4 c,n a. xEo.c+r,e AND GUTTER $ffivvavvv�o<vvr: 2 2 6 z SIDEWALKS 0 0 a 0 a 0 a 0 A B •_ , nnr'n00 +c _� a CONCRETE BLOCKS CLAY OR CONCRETE BRICKS MINIMUM (36) BRICKS MINIMUM (8) BLOCKS OF 512E OF SIZE 4"W x 8"L x 2 1/4"H 12"W x 12% x 2"H NOTES= 1- DLtectoble warning dames will rover 2'-13" length and folk width of the ramp floor as shown on the details, 2. Detectable warning dames will contrast visibility with adjoining surface, either light -on -dark, or dark -on -light sequence covering the entire ramp. 3. Portland cement / sand mix 50% by weight sand. Install as dry mix. Hand tamp for compaction and level before setting bricks. 4. Bricks should be butted as close together as allows. Sweep Portland cement / sand mix into remaining cracks. DURHAM blicWarks City of Durham, NC Voice [919}560 326 101 C 701 Citytyt. uF Hall Pfaza Durham, N.C. 2-1-101 USE WITH THE STANDARD SPECIFICATIONS ONLY www.durharim-gay DETECTABLE To ��""" Nos To Scale 2 405.09 WARNING DOMES REVISION DATE SHEETA uiFw I>ioM ,Iona, 2017 1 1 of 2 SEE SHEET 1 OF 2 FOR CURB + TYPE / DIME a� 4" COMPACTED A.B.C. UNDER ALL CURB + GUTTER TCP OF CURB HOT APPLIED JOINT SEALER 1 /2"� �� AFTER REMOVAL OF 3 /S" RADIUS 1/2"-3/4" OF EXPANSION JOINT MATERIAL 1/8" RADIUS SURFACE of GUTTER .' 1,{ +EXPANSfON JOINT' TRANSVERSE EXPANSION JOINT IN CURB AND GUTTER NOTES= Use non --reinforced, air entrained, concrete with a minimum strength of 3000 lbs. 2, Contraction joints shall be placed at 10' intervals. 3. Contraction joints may be installed by the use of templates or formed by other approved methods. Where such joints are not formed by templates, a minimum depth of 1 1/2" shall be obtained, 4- All construction joints shall be filled with joint filler and hot applied joint sealer. See NCDOT specifications, 5. Expansion joints shall be spaced at 90' intervals, and adjacent to all rigid objects DURHAM 5' MAX Depl. of 101CtyHallIcan City of Durham, N C 107 City Hall IN Pan Voice j919)560d32G - - - - - - - - - - - - Durham, N.C. 27701 uSE W.TH THE STANDARD SPEC:.RCATION5 ONLY www.durhamnc.gov Verce(919)560-4326 z CONCRETE CURB Nei Tora Scale 3 s a ; 402 402.01 CONCRETE • EXPANSION JOINT Ream, DATE 51tEET a. 1 8 8 4 c,n a. xEo.c+r,e AND GUTTER lune, 201 1-1 -10 2 2 vARiES I Y w a i_ N 0 a a L1. Q' �a al� v ;��JJ C-.41 TYPICAL SIDEWALK with (VERGE) GRASS UTILITY STRIP GRASSED uT1LITY 5TR1P MIN. (SEE CITY SITE PLANS) (VERGE) Z VARIES VARIES TOOLED EOCE (TYPICAL) :1 MIN. 4" THICK Seep P51 CONCRETE S/w CURB do GUTTER lir+l;.IF 29 MAX_ - PAVEMENT � 11-7 a I CeMPACTEe SUBGRADE TO A DENSITY OF NO LESS THAN 100% SECTION C -C r SEE SHEET 3 (THIS DETAIL) 5' MAX FOR SECTION A -A, B -B AND NOTES RIGHT OF WAY LINE - - - - - - - - - - - - DURHAM Dept. of Public Works �;�{/ of Durham, NC TOT City Hall PPaza i Verce(919)560-4326 z 1/2'• TRAVERSE o mm.durhamne-goo CONCRETE • EXPANSION JOINT SCACONCRETE Not Not Tq scale s 75 a 6 (SEE NOTE 3)� z' .. • 6 6 z SIDEWALKS •, A� 0 A' H A B •_ , +c _� a d' c • • z - v 4 Z '{ a • z o a _ e a, GRASSED UTILITY STRIP (VERGE) Q' �a al� v ;��JJ C-.41 TYPICAL SIDEWALK with (VERGE) GRASS UTILITY STRIP GRASSED uT1LITY 5TR1P MIN. (SEE CITY SITE PLANS) (VERGE) Z VARIES VARIES TOOLED EOCE (TYPICAL) :1 MIN. 4" THICK Seep P51 CONCRETE S/w CURB do GUTTER lir+l;.IF 29 MAX_ - PAVEMENT � 11-7 a I CeMPACTEe SUBGRADE TO A DENSITY OF NO LESS THAN 100% SECTION C -C r SEE SHEET 3 (THIS DETAIL) 5' MAX FOR SECTION A -A, B -B AND NOTES City of Durham, N C i Voice (919) 560-4326 DJB DURHAM Dept. of Public Works �;�{/ of Durham, NC TOT City Hall PPaza i Verce(919)560-4326 z EXPANSION JOINT Durham. N.C. 27701 USE W:T?I THE STANDARD SPECIFICATIONS ONLY mm.durhamne-goo CONCRETE cC3 1/2" TRAVERSE SCACONCRETE Not Not Tq scale }ErV M a 402.02 75 a 1 9 6 9 SIDEWALKS REVISION0 5HEEi4. 8 SIDEWALKS June,una.2201717 1 � 3 SEAL A ISSUED FOR PERMIT 2019.04.05 REV.NO. DESCRIPTIONS DATE REVISIONS SEAL 497/''7/i A-4MY, ES N OI�'1'q •,►1J 028419 . 4/05/2019 Q //1111111110" \ 1. North Carolina General Statute 136-44.14 requires that all street curbs being constructed or reconstructed for maintenance procedures, traffic operations, repairs. Correction of utilities or altered for any reason after September, 1, 1973 shall provide curb romps for the physically disabled of all intersections where both curb and gutter and sidewalks are provided and at other points of pedestrian flow. In addition, section 228 of the 1973 Federal Aid Highway Safety Act requires provision of curb ramps on any curb construction after July 1, 1976 whether a sidewalk is proposed initially or is planned for a future date. The Americans with Disability Act (ADA) of 1990 extends to individuals with disabilities- Comprehensive civil rights protections similar to those provided to persons on the basis of race, sex, national origin and religion under the Civil Rights Act of 1964. These curb ramps have been designed to comply with the current ADA standards (2010 ADA Standards for Accessible Design, dated September 15, 2010 & effective March 15, 2012)- 2. 0T2)- 2. Curb ramps are required when streets are altered for resurfacing (spanning one intersection to another and includes overlay of additional material to the road surface with or without milling), reconstructed, rehabilitafed or widened. Maintenance activities an streets, such as crock filling sealing, pavement markings, surface sealing and pavement patching, are not alterations. However, if there is no block -to --block resurfacing but resurfacing is occurring at a crosswalk itself, partial resurfacing (curb--to-curb resurfacing of ❑ crosswalk) requires the provision of curb ramps of that crosswalk. Curb ramps are not required in the absence of a pedestrian walkway with o prepared surface nor are curb ramps required in the absence of curb, elevation or other barrier between the street and the walkway. [USDOJ July 8, 2013] 3. Curb ramps are required at all curb returns. 4. Detectable warning domes are required for curb romps. 5. Single curb ramp at the center of the return are permitted under special circumstances. 6. Dimensions assume 90' centerline intersection of streets. 7. Construct the ramp surface to be stable, firm and slip resistant. Lacaled and construct the curb ramp type as shown in these details. 8. Curb ramps shall be constructed perpendicular to the roadway travel lane. 9. Coordinate the curb ramp and pedestrian crosswalk markings so a 4'x4' clear space at the base of the curb ramp will fail within the pedestrian crosswalk lines. 10. Set back distance from inside corner of an intersection crosswalk marking to nearest edge of travel lane is 4 feet minimum. 11. Terminate parking a minimum of 20 feet back of a pedestrian crosswalk. 12. Construct a curb ramps o minimum of 4 feet wide. Width may exceed 4 feet. 13. Construct the running slope of the ramp of a maximum of 8.33% (1 : 12). 14. Allowable cross slope on sidewalks and ramps to be a maximum of 2%. 15. Construct the side flare slope to a maximum of 10% measured along the curb line.; 16. Construct the counter -slope of the gutter or street at the base of the curb ramp at a maximum of 5% and maintain a smooth transition. 17. Construct landings for sidewalk of a minimum of 4'x4' with ❑ maximum slope of 2% in any direction. Construct landings for median islands a minimum of 5'x5' with a maximum slope of 2% in any direction. DURHAM Depl. DF 101CtyHallpwarks City of Durham, N C Vaicel949)560.4328 107 City Hall Pfaza + Durham. N.C. 27701 USE W1THI SNE STANDARD 5PECIFIC,4TIONS ONLY www.durhamnc.gav CURB RAMP �To c hC 5.A112 Not To Scale � 405.2+] 1 8 6 9 NOTES ES REVISIONDATE SNEET>; Juno, 2017 1 # 2 D n III 5' MAX RIGID STRUCTURE 5' MAX Dept. ty Hall P Warks 101 Ci Hall Plaza City of Durham, N C i Voice (919) 560-4326 DJB DESIGNED Durham, N.C. 27701 USE W:TH Ti.E 51 11DARD SPECIFICATIONS ONLY z EXPANSION JOINT I z CONCRETE cC3 1/2" TRAVERSE 75 a REVISION OATS EXPANSION JOINT a 1 x s 9Jvrre, .maFusls�er.,r± 8 SIDEWALKS x017 2 a 3 (SEE NOTE 3) ul • a, a'• , L Q- a < L,W V W V V ' + EXPANSION JOINT ' 0, U c 'Fl V AMW ❑� SIDEWALK abutting CURB 1 RIGID STRUCTURE (SEE SITE PLANS) 1/2" EXPANSION JOINT W - - MIN 6' Ht34DD PSI CONCRETES/WCURS & GUTTER 2% MAX. � PAVEMENTS Cn _ COMPACTED W13GRADE TO A DENSITY OF NO LESS THAN 100% SECTION D -D SEE SHEET 3 (THIS DETAIL) FOR SECTION A-.4, B -B AND NOTES v vNFK11\4& CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com 18. To use a median island as ❑ pedestrian refuge area, median isionds will be o minimum of 6 feet wide. Construct median islands to provide passage over or through the island. 19. Small channelization islands that cannot provide a 5'x5' landing at the top of a curb ramp, will be cut through level with the surface of the street. 20. Curb ramps with returned side curbs may be used only where pedestrians would not normally walk across the ramp such as where there the adjacent surface is plantings, other non -walking surface, or the side approach is substantially obstructed. 21. The typical 2'x4' truncated dome pad sholl be placed with the short dimension (5' max) perpendicular to the curb. See curb ramp typical details. Truncated dome pads shall abutt the back of the curb (ICC/ANSI A117.1 Fig C406.13.2). 22. Curved truncated dome pods ore permitted when romp width is greater then 4 feet. 23. Color contrast required only when detectable warning plates are employed. (ADA Standards for Accessible Design, section 705, Latest Edition). Recommended Min. light reflectance contrast is 70% (American National Standard ICC/ANSI A117,1 - Standard & Commentary Section 705.3, Latest Edition). Pointed surface will not be acceptable. (See note 4), 24. Place a 1/2 -inch expansion joint where the concrete curb rarnp joins/abuts the curb. 25. Curb ramps through median islands, single ramps at dual crosswalks or limited right-of-way situations will be handled by special details. Consult with the Town Engineer. 26. When construction is on a NCDOT Right -of -Way, construction shall conform to the latest edition of the NCDOT Roadway Standard drawings. 2/. Construction of curb ramps shall conform to the latest edition of the ICC/AN51 A117, Chapter 4 Accessible Routes. 28. Curb ramps shall be provided at locations as shown on plans or as directed by the engineer. Curb ramps shall be located as indicated in these details; however, the location may be adjusted as directed by the engineer where existing light poles, fire hydrants, drop inlets, otc. Affect placemont. At those locations, not less than 2 feet of full height curb shall be placed between adjacent ramps. 29. Use air entrained 3000 psi concrete with a sidewalk finish in order to obtain a rough non-skid type surface. 30. Crosswalk widths and configuration vary buf must conform to traffic design standards. 31. Place the inside pedestrian crosswalk lines no closer in the intersection then would be established by bisecting the intersection radii, with an allowance of a 4'x4' maneuvering space (2003 ICC/ANSI 0117 Commentary- Fig. 0406.6 & 406.10) in the vehicular travel way when one ramp is installed. 32. Place all pavement markings in accordance with the latest edition of the Manual of Uniform Traffic Control Devices (MUTCD) published by the Federal Highway Administration and the North Carolina Supplement to the MUTCD. 33. For asphalt greenways transition greenway to concrete to enable truncated dome placement. 34. Concrete must come from a ready mix concrete truck to ensure mix meets air entrainment requirements. No site mix or sakrete mix allowed. 35, The longitudinal slope within the crosswalk shall not exceed 5%. ❑URHAM Depl. of 101CtyHallIcan City of Durham, N C Voiiej919)560�326 107 City Hall IN Pan Durham, N.C. 27701 u5E W•TH THE STANDARD SPEC:IRCATIONS ONLY www.durhamnc.gov �iCALILEll CURB RAMP Nei U0ni a Top Scale s>4a5.2t7 NATES REVISION DATE SHEET a. 1 8 6 9 Juno, 201-1 2 0 2 a r y • • .. ■ f 1/8" RADIUS" •' s 1/2' EXPANSION ; a JOINT FILLER 4. ' -a d. �1/2.. SECTION A -A SECTION B -B TRANSVERSE EXPANSION CONTRACTION (GROOVE) JOINT IN SIDEWALK JOINT IN SIDEWALK NOTES: 1. In addition to complying with Durham standards sidewalks shall conform to NCDQT standards and specifications. In cases where clarifications are needed, the City shall make the determination. 2. Contraction (Groove) joints with 1/8" radius shall be placed at 5 foot intervals and be one inch deep with joint filler. 3. One half inch (1/2") transverse expansion joints shall be placed at intervals no more than 50 feet and shall match expansion/construction joints in adjacent curb. 4. A sealed 1/Z" expansion joint is required where the sidewalk abuts buildings or any rigid structure. 5. Joint materials shall limit shrink/swell so post construction installation results in o maximum of 1/4" from flush. 6. Concrete compressive strength shall be 3,004 psi in 28 days. 7. Top 6" of subgrade beneath the sidewalk shall be compacted to 100% Standard Proctor density. The City may require testing at its discretion. 8. Six inch depth is required at all driveways, intersections (PC to PT), at Handicap ramps, and commercially developed or zoned areas. 9. Undercutting of unsuitable subgrade material and/or placement of up to 6 inches of incidental ABC stone moy be required to obtain proper bedding. 10. The minimum width of the verge is one foot; otherwise the sidewalk shall abut the bock of the curb and be six feet wide and six inches thick. 11. Lids for junction boxes, structures, or utility vaults shall be non-skid, meet NCDOT standards, and be submitted to the City for review and approval prior to installation. 12. Provide a minimum one foot wide flat area of the back of sidewalks before starting any cut or fill slope, ■' JURHAM Dept. olPublic Works Cl y of Durham, ,■ G Voice (9191560-4326 101 Ci Hall Plaza Durham, N.C. 27701 USE W TH THE STANDARD SPECIHCATIONS ONLY www_dLkrhamnc.gov CONCRETE 3oS ❑02I-0 NM To Scala 4a2.o2 SIDEWALKS REVISION OATS 5l-IFv d June, 2017 3 oT 3 EX. CURB ANO EX. PAVEMENT SEE NOTE 2 TRANSITION POINTS TRANSITION POINTS 8.332 (12: T) M TRUNCATED DOMES PER DETAIL 405.05" - G 1 4 {� < 77I= , -III, • 2 1 1/4" MAX ¢ 11V MAX:F < A • 1/4" MAX ,g• VERTICAL LIP VERTICAL LIP WITH BEVEL NOTES= 1- The transition between the fruncoted dome tray and the curb should be mode to be flush. The transition between the curb and the gutter should be smooth or rounded. If neither a flush or smooth transition can be constructed, and the transitions change in level, up to %", then the lip may be vertical and without edge treatment. If the transitions change in level, between %" and %2", then the lip shall be beveled with a slope no greater than 1:2. 2. This detail is for transition paints only, refer to curb cut details for proper curb layout / design. (City Std. Details 405.01 thru 405.07) 0RHAM Depl.oFPub11cWarks City of Durham, N C Voice[9%9 560.4326 101 City Hall Pfaza i Durham. N.C. 27-101 USE WITH THE STANDARD SF:ECIHCATiONS ONLY www.durhamnc glov CURB CUT RAMP SCALL b05 Not To Scala �40ri 0E1 TRANSITION POINTS REV ISI 17 5~EETA 1 6 6 4 c,r. o. rrar.•rr Juno, 2017 1 # 1 PROPOSED OR FUTURE SIDEWALK (5' SM.) 4410 1 EXPANSION JOINT ISOMETRIC VIEW C�PAY LIMITS FOR CURS RAMP 4'x4' LANDING AUile., 4' MIN. EXPANSION J01NT � 5' MIN. CURB TRANSITION 4' MIN. DROP CURB 5' MIN, CVRB TRANSITION VARIABLE SIDE EXPANSION SLOPES, NOT TO JOINT SIDEWALK ELEVATION-\ EXCEED 10:1 �, sP TDP OF CURB DETECTABLE GUTTERLINE WARNING DOMES SECTION A -A CURB UTILITY STRIP, SEE STREET PAVEMENT & GUTTER CROSS SECTION DETAILS SIDEWALK (5' STD,) (MOTH & SLOPE VARIE5) 6- MAX SIDE FLARE MAX. RAMP SLOPE 12:1 DROP SLOPE 10:1 2% MAX CURB j r - L EXPANSION JOPIN T DETECTABLE y 4'x4' LANDING WARNING DOMES SECTION B -B 4'x4' LANDING NOTES= 1. Detectable warning domes will cover 2'-0" length and full width of the ramp where it is flush with the pavement. DURHAM Dept of Public Works C;�{/ of Durham, N C Vvice (919) M-4326 TOT City Hall Plaza i Durham. N.C. 27701 rJ SE W T91 THE STANDARD SPEC IF tCATIONS ONLY www.dwhamric.guv SINGLE CURB RAMP SCALE OEM 406.N Not 7n scale 405. a3 WITH PROPOSED CURB & GUTTER REVISION DATE ;HOT z 1 9 B 9 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA SITE DETAILS DATE: APRIL 5, 2019 Dept. ty Hall P Warks 101 Ci Hall Plaza City of Durham, N C i Voice (919) 560-4326 DJB DESIGNED Durham, N.C. 27701 USE W:TH Ti.E 51 11DARD SPECIFICATIONS ONLY www.durhamnc.gov PROJ. MGR. Jul CONCRETE , Not To Scale ❑02I-0 -.4a2.o2 REVISION OATS 57-IEET b 1 x s 9Jvrre, .maFusls�er.,r± SIDEWALKS x017 2 a 3 v vNFK11\4& CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com 18. To use a median island as ❑ pedestrian refuge area, median isionds will be o minimum of 6 feet wide. Construct median islands to provide passage over or through the island. 19. Small channelization islands that cannot provide a 5'x5' landing at the top of a curb ramp, will be cut through level with the surface of the street. 20. Curb ramps with returned side curbs may be used only where pedestrians would not normally walk across the ramp such as where there the adjacent surface is plantings, other non -walking surface, or the side approach is substantially obstructed. 21. The typical 2'x4' truncated dome pad sholl be placed with the short dimension (5' max) perpendicular to the curb. See curb ramp typical details. Truncated dome pads shall abutt the back of the curb (ICC/ANSI A117.1 Fig C406.13.2). 22. Curved truncated dome pods ore permitted when romp width is greater then 4 feet. 23. Color contrast required only when detectable warning plates are employed. (ADA Standards for Accessible Design, section 705, Latest Edition). Recommended Min. light reflectance contrast is 70% (American National Standard ICC/ANSI A117,1 - Standard & Commentary Section 705.3, Latest Edition). Pointed surface will not be acceptable. (See note 4), 24. Place a 1/2 -inch expansion joint where the concrete curb rarnp joins/abuts the curb. 25. Curb ramps through median islands, single ramps at dual crosswalks or limited right-of-way situations will be handled by special details. Consult with the Town Engineer. 26. When construction is on a NCDOT Right -of -Way, construction shall conform to the latest edition of the NCDOT Roadway Standard drawings. 2/. Construction of curb ramps shall conform to the latest edition of the ICC/AN51 A117, Chapter 4 Accessible Routes. 28. Curb ramps shall be provided at locations as shown on plans or as directed by the engineer. Curb ramps shall be located as indicated in these details; however, the location may be adjusted as directed by the engineer where existing light poles, fire hydrants, drop inlets, otc. Affect placemont. At those locations, not less than 2 feet of full height curb shall be placed between adjacent ramps. 29. Use air entrained 3000 psi concrete with a sidewalk finish in order to obtain a rough non-skid type surface. 30. Crosswalk widths and configuration vary buf must conform to traffic design standards. 31. Place the inside pedestrian crosswalk lines no closer in the intersection then would be established by bisecting the intersection radii, with an allowance of a 4'x4' maneuvering space (2003 ICC/ANSI 0117 Commentary- Fig. 0406.6 & 406.10) in the vehicular travel way when one ramp is installed. 32. Place all pavement markings in accordance with the latest edition of the Manual of Uniform Traffic Control Devices (MUTCD) published by the Federal Highway Administration and the North Carolina Supplement to the MUTCD. 33. For asphalt greenways transition greenway to concrete to enable truncated dome placement. 34. Concrete must come from a ready mix concrete truck to ensure mix meets air entrainment requirements. No site mix or sakrete mix allowed. 35, The longitudinal slope within the crosswalk shall not exceed 5%. ❑URHAM Depl. of 101CtyHallIcan City of Durham, N C Voiiej919)560�326 107 City Hall IN Pan Durham, N.C. 27701 u5E W•TH THE STANDARD SPEC:IRCATIONS ONLY www.durhamnc.gov �iCALILEll CURB RAMP Nei U0ni a Top Scale s>4a5.2t7 NATES REVISION DATE SHEET a. 1 8 6 9 Juno, 201-1 2 0 2 a r y • • .. ■ f 1/8" RADIUS" •' s 1/2' EXPANSION ; a JOINT FILLER 4. ' -a d. �1/2.. SECTION A -A SECTION B -B TRANSVERSE EXPANSION CONTRACTION (GROOVE) JOINT IN SIDEWALK JOINT IN SIDEWALK NOTES: 1. In addition to complying with Durham standards sidewalks shall conform to NCDQT standards and specifications. In cases where clarifications are needed, the City shall make the determination. 2. Contraction (Groove) joints with 1/8" radius shall be placed at 5 foot intervals and be one inch deep with joint filler. 3. One half inch (1/2") transverse expansion joints shall be placed at intervals no more than 50 feet and shall match expansion/construction joints in adjacent curb. 4. A sealed 1/Z" expansion joint is required where the sidewalk abuts buildings or any rigid structure. 5. Joint materials shall limit shrink/swell so post construction installation results in o maximum of 1/4" from flush. 6. Concrete compressive strength shall be 3,004 psi in 28 days. 7. Top 6" of subgrade beneath the sidewalk shall be compacted to 100% Standard Proctor density. The City may require testing at its discretion. 8. Six inch depth is required at all driveways, intersections (PC to PT), at Handicap ramps, and commercially developed or zoned areas. 9. Undercutting of unsuitable subgrade material and/or placement of up to 6 inches of incidental ABC stone moy be required to obtain proper bedding. 10. The minimum width of the verge is one foot; otherwise the sidewalk shall abut the bock of the curb and be six feet wide and six inches thick. 11. Lids for junction boxes, structures, or utility vaults shall be non-skid, meet NCDOT standards, and be submitted to the City for review and approval prior to installation. 12. Provide a minimum one foot wide flat area of the back of sidewalks before starting any cut or fill slope, ■' JURHAM Dept. olPublic Works Cl y of Durham, ,■ G Voice (9191560-4326 101 Ci Hall Plaza Durham, N.C. 27701 USE W TH THE STANDARD SPECIHCATIONS ONLY www_dLkrhamnc.gov CONCRETE 3oS ❑02I-0 NM To Scala 4a2.o2 SIDEWALKS REVISION OATS 5l-IFv d June, 2017 3 oT 3 EX. CURB ANO EX. PAVEMENT SEE NOTE 2 TRANSITION POINTS TRANSITION POINTS 8.332 (12: T) M TRUNCATED DOMES PER DETAIL 405.05" - G 1 4 {� < 77I= , -III, • 2 1 1/4" MAX ¢ 11V MAX:F < A • 1/4" MAX ,g• VERTICAL LIP VERTICAL LIP WITH BEVEL NOTES= 1- The transition between the fruncoted dome tray and the curb should be mode to be flush. The transition between the curb and the gutter should be smooth or rounded. If neither a flush or smooth transition can be constructed, and the transitions change in level, up to %", then the lip may be vertical and without edge treatment. If the transitions change in level, between %" and %2", then the lip shall be beveled with a slope no greater than 1:2. 2. This detail is for transition paints only, refer to curb cut details for proper curb layout / design. (City Std. Details 405.01 thru 405.07) 0RHAM Depl.oFPub11cWarks City of Durham, N C Voice[9%9 560.4326 101 City Hall Pfaza i Durham. N.C. 27-101 USE WITH THE STANDARD SF:ECIHCATiONS ONLY www.durhamnc glov CURB CUT RAMP SCALL b05 Not To Scala �40ri 0E1 TRANSITION POINTS REV ISI 17 5~EETA 1 6 6 4 c,r. o. rrar.•rr Juno, 2017 1 # 1 PROPOSED OR FUTURE SIDEWALK (5' SM.) 4410 1 EXPANSION JOINT ISOMETRIC VIEW C�PAY LIMITS FOR CURS RAMP 4'x4' LANDING AUile., 4' MIN. EXPANSION J01NT � 5' MIN. CURB TRANSITION 4' MIN. DROP CURB 5' MIN, CVRB TRANSITION VARIABLE SIDE EXPANSION SLOPES, NOT TO JOINT SIDEWALK ELEVATION-\ EXCEED 10:1 �, sP TDP OF CURB DETECTABLE GUTTERLINE WARNING DOMES SECTION A -A CURB UTILITY STRIP, SEE STREET PAVEMENT & GUTTER CROSS SECTION DETAILS SIDEWALK (5' STD,) (MOTH & SLOPE VARIE5) 6- MAX SIDE FLARE MAX. RAMP SLOPE 12:1 DROP SLOPE 10:1 2% MAX CURB j r - L EXPANSION JOPIN T DETECTABLE y 4'x4' LANDING WARNING DOMES SECTION B -B 4'x4' LANDING NOTES= 1. Detectable warning domes will cover 2'-0" length and full width of the ramp where it is flush with the pavement. DURHAM Dept of Public Works C;�{/ of Durham, N C Vvice (919) M-4326 TOT City Hall Plaza i Durham. N.C. 27701 rJ SE W T91 THE STANDARD SPEC IF tCATIONS ONLY www.dwhamric.guv SINGLE CURB RAMP SCALE OEM 406.N Not 7n scale 405. a3 WITH PROPOSED CURB & GUTTER REVISION DATE ;HOT z 1 9 B 9 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA SITE DETAILS DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 DRAWN DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML SCALE HORIZONTAL: N/A VERTICAL: N/A M&C FILE NUMBER D 1.0 DRAWING NUMBER Dl .0 STATUS; REVISION NOT FOR CONSTRUCTION A ISSUED FOR REVIEW ONLY SEE MUTEANDIkG ' a ,Q- -� .1�? ISOMETRIC VIEW EXPANSION JOINT WHERE q'1' IL ` aMNw. 'Pox r DETECTABLE WARNING 2.fl� SIDEWALK AREA r ! SPAY LIMITS FOR CURB RAM DETECTABLE WARNING NEW CONC ABUTS EX.pF EX. CURB �P at r & GUTTER 211" TYP. F • r MIN. TRANSITION es'o .� +2" 14A%. SURFACE. CONCRETE (TYPICAL) 12" MIN. 10.0% MAX. CURB Y EXPANSION VARIABLE SIDE I JOINT SIOEWALtt 5L9P1_5, NOT 70 6".12" - - ELEVATION EXCEED 10:1 CONCRETE CURB - - _ - R■ - - - - - Fit �I[ fa I[irGi[GS�� EX. CURB DETECTABLE GUTTER LINE & GUTTER WARNING DOMES I CURB ELEVATION S" MIN EX. CURB EX. • EXPANSION JOINT 6. `q EXPANSION JOINT 6"x12" CONC- CURB -------�---- DROP s CURB - - - - - - - - T `1TI-IT7_-7- fi`��L : LU LLO Min. 2.0% }uSAx: • . 1, Maximum curb romp slope 8.33% (12:1) r EX. CURB rU & GUTTER and longitudinal scope of 2.405 where pedestrlans perform turning maneuvers. 5.1• 4- Detectable warning domes will cover 2'-0- length and full width of the ramp S3 ,Uo DepL of 101CittyHall caza City of Durham, N C Yoloa[919}SBR4S28 101 Ci Hall Plaza w Durham. N.C. 27701 USE WITH THE STANDARD SPECIFICATIONS ONLY MAMB+_4urhamGIC.80V CURB RAMPS - SHARED LANDING NaI� Ie z40 07 61 OFF WDLE 61 1s69 CURB R J�ns 2U 7 z 3 h n. HORIZONTAL RAILS FDR MAY BE CONSTRUCTED OF APPROVED COMPOSITE, HOLLOWICGRNUGATED AND RIGHT TURN ARROW CURB TRANSITION �� op 2- BARRICADE SHALL BE LIMITED TO A MAXIMUM LENGTH OF B FT UNLESS NCHAP 350 CRASH TESTED Cc Q TRANSITION 1p.0% MAX. W_. 100% "Ak 3- 100°% rr 104% MAX. i z MIN. WIND AND TRAFFIC CONDITIONS, ~ 1 +" Q CURB TRANSITION IO •'� 1{l,Ox MAX.MAx, 5' LAIN CURB TRANSITION 4' MEN DROP CURB CURE TRANSITION EXPANSION VARIABLE SIDE JOINT SLOPE5. NOT To SIDEWALK ELEVATION EXCEED 1Q 1 EX. CURB & GUTTER DETECTABLE f GUTTER LINE -f 11 WARNING DOMES PARTIAL CURB ELEVATION CORD UTILITY STRIP. SEE STREET PAVEMENT & GUTTER CROSS SECTION DETAILS SIDEWALK - - „ (VADTH & SLOPE VARIE5) 6 - FLA. SIDE MAX RAMP SLOPE 12:1 DROP SLOPE 10.1 2%d MAX � # CURB ------------ rT.; Tt :d • _ •I I_I I I=I EXPANSION I- , JOPINT 4'1(DETECTABLE4' LANDING- WARNING Da1.tE5 SECTION A -A MIN. 4'x4' LANDING. I A 1!•STCGN. 1. Maximum curb ramp slope 8.33% (12:1) 2. Maximum cross slope 2.005 3. Curb ramps require a (4'-0") minimum landing. with a maximum cross slope and longitudinal slope of 2.00% where pedestrians perform turning maneuvers. Slope to drain to curb - 4. Detectable warding domes will cover 2'-•0- length and full width of the ramp where it is flush with the pavement. DURHAfN Dept. of Public Works City of Durham, NC Voiaa(919)SM4326 101 City Hall Plaza Durham, N.C. 27701 USE W11H THE $TANIIARD SPECIRC01ONS ONLY w _durhamru;•,aov CURB RAMPS - SHARED LANDING Nd a`SceIe 740 07 11 1 8 6 TYPE E REV151 ON PATE SHEET a: 6¢DCrvC June 2011 1 a 3 1.5" S -9.5B SURFACE 1.5" I -19.0B BASE COURSE 0" AGGREGATE BASE COURSE (TYP.) COMPACTED SUBGRADE PER GEOTECHNICAL RECOMMENDATIONS (TYP.) TYPICAL MINIMUM PAVEMENT PATCH SECTION NOTES: 1. THE PAVEMENT CUT SHALL BE DEFINED BY A STRAIGHT EDGE AND MUST BE MACHINE SAW CUT. 2. SUBGRADE TO BE COMPACTED PER GEOTECHNICAL RECOMMENDATIONS. 3. BASE TO BE COMPACTED PER GEOTECHNICAL RECOMMENDATIONS. 4. BITUMINOUS MATERIAL SHALL CONFORM TO THE LATEST NCDOT SPECIFICATIONS. 5. ALL WORKMANSHIP SHALL CONFORM TO THE LATEST NCDOT STANDARDS AND PERFORMANCE SPECIFICATIONS. 6. THE ENTIRE THICKNESS AND VERTICAL EDGE OF CUT SHALL BE TACKED. 7. THE ASPHALT PAVEMENT MATERIAL SHALL BE INSTALLED AND COMPACTED THOROUGHLY TO ACHIEVE A SMOOTH LEVEL PATCH. HEAVY DUTY ASPHALT- PAVEMENT SECTION N TS ISOMETRIC VIEW t F Amw SIDEWALK r Olt C�PAY LIMITS FOR CURB RAMP It. ��AR£A �1 4•Ir4' MIN, LANDING r r EXPANSION JOINT WHERE SEE NOTE 3 �� � �` ��H- V r �r NEW CONC ABUTS EX. Xw. �p r 6 x12" CONCRETE CURE CONCRETE (TYPICAL) ` aMNw. 'Pox r DETECTABLE WARNING 2.fl� 1 SURFACE. Ak U PROJ. MGR. 1 ~ 1 dsk r, EX. CURB �P at r & GUTTER 211" TYP. F 12" MIN.O t 3•, 10 - CURB r CURB MIN. TRANSITION es'o .� +2" 14A%. 8" iYP. 24' TYP. CURB TRANSITION 12" MIN. 10.0% MAX. CURB TRANSITION 4' MIN. DROP CURB CURB TRANSITION CURB TRAN511ION 4' 11111, DROP CURB EXPANSION VARIABLE SIDE I JOINT SIOEWALtt 5L9P1_5, NOT 70 6".12" - - ELEVATION EXCEED 10:1 CONCRETE CURB - - _ - R■ - - - - - Fit �I[ fa I[irGi[GS�� EX. CURB DETECTABLE GUTTER LINE & GUTTER WARNING DOMES I CURB ELEVATION S" MIN EX. CURB EX. EX. 51DEWALK RAMP (VARIES) MAX. SLOPE 12:1 do GUTTER PAVEMENT EXPANSION JOINT 6. `q EXPANSION JOINT 6"x12" CONC- CURB -------�---- DROP s CURB - - - - - - - - T `1TI-IT7_-7- `'-' ''=111=_III= _ � � � •'�;= LU LLO Min. DETECTABLE MIN. 4•x4• LANDING. SECTION B -B WARNING DOMES 4•4' SANDING. NOTES; 1, Maximum curb romp slope 8.33% (12:1) 2- Maximum cross slope 2.00% 3. Curb ramps require a (4'-0") minimum landing. with a maximum cross slope and longitudinal scope of 2.405 where pedestrlans perform turning maneuvers. Slope to drain to curb. 4- Detectable warning domes will cover 2'-0- length and full width of the ramp where it is flush with the pavement. DURHAM DepL of 101CittyHall caza City of Durham, N C Yoloa[919}SBR4S28 101 Ci Hall Plaza w Durham. N.C. 27701 USE WITH THE STANDARD SPECIFICATIONS ONLY MAMB+_4urhamGIC.80V CURB RAMPS - SHARED LANDING NaI� Ie z40 07 61 OFF WDLE 61 1s69 TYPE 4A R J�ns 2U 7 z 3 h n. HORIZONTAL RAILS FDR MAY BE CONSTRUCTED OF APPROVED COMPOSITE, HOLLOWICGRNUGATED AND RIGHT TURN ARROW ,r I�II��1�ItaZ41T1�:7A\'1 TIE NEW PAVEMENT TO EXISTIN A ISSUED FOR PERMIT 2019.04.05 REV.NO. DESCRIPTIONS DATE N. REVISIONS 2.0' MIN. MILLING LIMITS 1' MIN. EXISTING PAVEMENT I / SAWCUT EXISTING iiffiin, D NEW PAVEMENT - FULL DEPTH (SEE CORRESPONDING TYPICAL SECTION FOR REQUIRED PAVEMENT STRUCTURE) PAVEMENT TRANSITION, DETAIL SEs NTS SEAL CARO��ti, , %PEES - _ L 028419 4/05/2019 i TYPE III BARRICADE TYPE III BARRICADE o A' RA%IK N ISEE N9TE P] E}IO-Di-110AIAY4Y APALLCATI9N3 Q a DJB TURN ARROW LEFT OR RIGHT TURN ARROW is• ns- U PROJ. MGR. r IZ-I 4NLES5 OTHERIYISEP SHMN. USE 2'-6VSP MINI -SKIPS FOR >_ LLJ❑ z +2" 14A%. 8" iYP. Q Q v Q ¢ U EDGE EDGE LINE 36., 36"CL V2i W ¢Q LL- _ " 4 16" 'o,30' LL J a_t-r H- lk-M FWN LU LLO Min. o u; Q ALTERNATE ORANGE & WHITE STRIPES z'rvP. ALTERNATE GRANGE & WHITE STRIPES � U < o = tr � H H > YELLOW OR WHTTE � F -I LANE LINE w ' LU 9TABILIZEB BAA REQNI9E0I LSTABIL12F BAP REONIRED) W�~a-1 BEF. NDIE 61 OFF WDLE 61 LEFT AND STRAIGHT YELLOW OR WHITE GENERAL NOTES WHITE 1- HORIZONTAL RAILS FDR MAY BE CONSTRUCTED OF APPROVED COMPOSITE, HOLLOWICGRNUGATED AND RIGHT TURN ARROW Cr ❑ C CC EXTRUDED RIGID POLYOLEFIN,. HIGH DENSITY POLYETHYLENE, OR OTHER NCDOT APPROVED MATERIAL. op 2- BARRICADE SHALL BE LIMITED TO A MAXIMUM LENGTH OF B FT UNLESS NCHAP 350 CRASH TESTED Cc Q z rI a0 H FOR CATEGORY II DEVICES AND NCDDT APPROVED. LL 3- ONLY NGDOT APPROVED COMPOSITE AND ROLL -UP SIGNS MAY BE MOUNTED ON THE BARRICADE RAILS. CJ" r CL C7 MOUNT SIGNS T4 BARRICADE RAILS TO ENSURE SIGN WILL NOT BECOME OETACHED UNDER NORMAL z a WIND AND TRAFFIC CONDITIONS, ~ 1 +" Q YFLLOW Q 4- SIGNS SHALL BE MOUNTED A MINIMUM OF 1 FOOT FROM THE GROUND TO THE BOTTOM OF THE SIGN Cc FOR THE COMBINATION STRAIGHT AND LEFT/RIGHT TURN ARROW UNLESS SIGNS R11-3 OR R11-4 ARE REWIRED BY THE PLANS OR DIRECTED BY THE ENGINEER. � a H 3 9' 5- BARRICADE MUST BE NGHRP 354 FOR CATEGORY II DEVICES AND NCDO7 APPROVED WITH STABILIZER � 0 r-1 BAA OR ADEGUATE LATERAL BRACING. W 8}2" MERGE ARROW z CL 6- ASSEMBLY OF THE GENERIC BARRICADES MUST BE SELF CERTIFIED BY THE ASSEMBLER, fl 20„ Id'_O" ¢ I- I- BARRICADES USED TO CLOSE A ROADWAY SHALL EXTEND ACROSS THE ENTIRE ROADWAY. WHERE H - Q U] LOCAL TRAFFIC MUST BE MAINTAINED, THEY MAY BE PLACED IN A STAGGERED PATTERN, m 11- STRIPES ON WORK ZONE BARRICADE RAILS SHALL BE ALTERNATE ORANGE AND WHITE > d RETROREFLECTIVE STRIPES, SLOPED DOWNWARD TOWARDS THE SIDE WHICH TRAFFIC IS TO PASS OR Q „ TURN IN DETOURING, WHERE NO TURNS ARE INTENDED, THE STRIPES SHOULD SLOPE DOWNWARD B" LESS THAN 45 MPH TOWARD THE CENTER OF THE: BARRICADE OR BARRICADES- Q - CC- 9- USE RED AND WHITE STRIPES FOR PERMANENT BARRICADES- rr 10- ALL BARRICADES MUST BE LISTED ON THE DEPARTMENT'S APPROVED PRODUCTS LIST. " �- 11- PLACE MANUFACTURER'S NAME AND FEDERAL HIGHWAY ADMINISTRATION'S NCHf1P 350 APPROVAL , S LETTER NUMBER ON BARRICADE FRAME. 0 12- PLACE SANDBAGS OR OTHER APPROVED BALLASTING METHODS ON THE FEET GF THE FRAME. DO NOT 0 Z - - 4'-43$" PLACE SANDBAGS ON TOP OF A STRIPED RAIL OR STABILIZER BAR. DO NOT BALLAST BARRICADES BY 16, 8.. 7,_1.• < LU G HEAVY OBJECTS SUCH AS ROCKS, CHUNKS OF CONCRETE OR OTHER ITEMS THAT WOULD CAUSE DAMAGE SHE 1 0�-/y� )_ Uj IF THE BARRICADE IS STRUCK BY A VEHICLE. T Yip RAP ARROW TMXIT 7'-0" TO BOTTOM OF LOWEST REQUIRED SIGN -1 REFLECTIVE ALUMINIUM ALVANIZED "U" CHANNEL POST PAINT CONCRETE BLACK AFTER CURING AT ASPHALT LOCATIONS 4000 PSI CONCRETE STOP SIGN DETAIL NTS v v &CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com 2'-O" 4" MIN. STRAIGHT ARROWI RIGHT OR LEFT COMBINATION STRAIGHT AND COMBINATION LEFT AND a DJB TURN ARROW LEFT OR RIGHT TURN ARROW RIGHT TURN ARROW QIn PROJ. MGR. GML 20' 4NLES5 OTHERIYISEP SHMN. USE 2'-6VSP MINI -SKIPS FOR >_ 20"SAME 6'-4' SKIP LANE LIkES 013 SKTP rElFTER LINES. DIMENSIONS APPLY AS FOR THE LEFTIRILiHT TURN ARROW Q ¢ U EDGE EDGE LINE 36., 36"CL V2i LLJ rIZ " 4 16" 'o,30' LL J a_t-r YELLOW OR WHITE N N B wdZL.L a" 113" U < o = tr YELLOW OR WHTTE q jo Cr LANE LINE w c� o�a"I6" W�~a-1 mCOMBINATION LEFT AND STRAIGHT YELLOW OR WHITE a1 WHITE 14" N G' AND RIGHT TURN ARROW Cr ❑ C CC 41 14rr m op w R-40" g z rI a0 H v N LU w CENTER LINE r CL C7 UNLESS OTHERWIEIEO SHOWN. USE T -9'ISP MINS-SKIPS FOR 4" a R=26" v SAME DIMENSIONS APPLY AS 1 +" Q YFLLOW + L- 12" 32" `v N 4" 32" FOR THE COMBINATION STRAIGHT AND LEFT/RIGHT TURN ARROW 3, 3, I 3 9' R=28" Q,- 4 , 8}2" MERGE ARROW ELONGATED STRAIGHT ARROW WRONG -WAY RAMP ARROW fl 20„ Id'_O" it 1a Q U] DIAGONAL LINE CRYSTAL,RSO LU (n 0 2.7 p" yp PAVEMENT MARKER $" 7yA. a„ `- EM 2i Br, Z (-n 117 F -I z 0 Q w „ y i1] B" LESS THAN 45 MPH Z Lu - CC- EN 2 6 OF RAMP r ��r 0 ❑ 14" " �- 0Ir , S Q 0 5, O 0 Z - - 4'-43$" 16, 8.. 7,_1.• < LU G 14 'All Z )_ Uj 8" TRANSVERSE+� Li 12" Yip RAP ARROW TMXIT 7 _j m 00 M WHITE 24" LONGITUDINAL « CC GENERAL NOTES: 1- USE THE COLOR WHITE FOR ALL PAVEMENT MARKING SYMBOLS. 3• DO NOT LOCATE PAVEMENT MARKING $YMBOLS AS TO ENCROACH INTO INTERSECTION AREAS. w 3- DO NOT PLACE SYMBOLS ACROSS TRANSVERSE EXPANSION JOINTS ON PORTLAND CEMENT CONCRETE PAVEMENTS, UNLESS APPROVED BY THE: ENGINEER. RAMP ARROW 4- CONFORM ALL SYMBOLS TO THE FHWA "STANDARD HIGHWAY SIGNS" MANUAL WHICH INCLUDES AT EXIT RAMP PAVEMENT MARKINGS AND STANDARD ALPHA3ETS (REFER TO SHEETS fi THRU 9] DIMENSIONS NDIE: 100 , CAN VARY AMONG MANUFACTURERS, THEREFORE SLIGHT VARIANCES ARE ACCEPTABLE. HOWEVER, ALL SYMBOLS ARE REQUIRED TO BE APPROVED BY THE DEPARTMENT, I. WHEN INSTALLING COLD APPLIED PLASTIC ON CONCRETEI7 I5 RECOMMENDED SHEET 1 OF//��9 TO USE COLD APPLIED PLASTIC WITH A BLACK CONTRASTING BOLDER. 11205 w 0 S CONTINUOUS LINES APRIL 5, 2019 10'-30'/SP SKIP LINE 2'-6'/SP MINI -SKIP LINE a DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML 1INLESS OTHERWTSED SHOR11, USE *'130'1SP SKIPS FOR 4NLES5 OTHERIYISEP SHMN. USE 2'-6VSP MINI -SKIPS FOR ¢ SKIP LANE LIkES 013 SKTP rElFTER LINES. LANE LINE EXTENSIONS THROUGH 1NTERSE0TT0NS, EDGE DINE Q EDGE EDGE LINE EXTENSIONS THROUGH INTERSECTIONS AND MINI -SKIPS USED FOR HTCYCLE LAKE LINES- 1 -- H CC [] " 4 16" 'o,30' LL J a_t-r YELLOW OR WHITE 1 Q CC _ a" 113" U < o = YELLOW OR WHTTE q jo Cr LANE LINE c� o�a"I6" W�~a-1 a"16„ YELLOW OR WHITE Ir O H ¢ O m cr WHITE Z H 3'-3'/SP MINI -SKIP LINE 3'-9'/SP MINI -SKIP LINE I -H LU w CENTER LINE 17NL8SS OTHERWISED SHOKRI, USE 3'•3'ISP 11INI-8KIP8 01 UNLESS OTHERWIEIEO SHOWN. USE T -9'ISP MINS-SKIPS FOR " 4 I6" THE WHTTV EbUit LINE ENTI_NSIONs A7 ACHMA13OUTS. MINI -SKIP LANE LINES AND LINE EXTENSIONS THROUGH TAPERS. YFLLOW GORE LINE 3, 3, I 3 9' 8}2" 7 WHITE WHITE WHITE DIAGONAL LINE LL LL 12" 45 NPN OR NIGHER y i1] B" LESS THAN 45 MPH Z Lu YELLOW OR WHITE U> LL 0 CROSSWALK LINE Z 8" TRANSVERSE+� cc ¢ WHITE 24" LONGITUDINAL Q ❑ w W CL RxR LINE co w >- � 16" ¢ s O C WHIIE J O � I STOP OR TRANSVERSE BAR GENERAL NOTES: 1- USE 6" LANE, EDGE, AND CENTER LINES ON ALL FULL CONTROL OF ACCESS FACILITIES AND OTHER ROUTES 24" A9 DIRECTED BY THE ENGINEER. WHITE 2- LANE LINES INDICATED AS "WIDE" ON THE ROADWAY STANDARD DRAWINGS SHALL BE AT LEAST TWICE THE WIDTH OF THE NORMAL LINE, 3- GORE LINES SHALL BE TWICE THE WIDTH OF THE NORMAL LINE. SHEET 1 OF 2 1205.01 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA SITE DETAILS DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 DRAWN DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML SCALE HORIZONTAL: N/A VERTICAL: N/A M&C FILE NUMBER D 1.0 DRAWING NUMBER D1.1 STATUS: REVISION NOT FOR CONSTRUCTION A ISSUED FOR REVIEW ONLY DROP HANDLE DROP HANDLE 1'--13 1/4" 7 1/2 as+ as ower T6FA., ■ a o.r■o "rin _ ........................... .. .. w.m N Lrj r r � ■nurrn �o ua LETTERS 5/8' FRAME TOP TOP OF COVER _ 2'-7" 2'-7" 6 t Q� - °.� 2 1/2--{ 1.. SECTION OF ASSEMBLY v � I Lj ....tea a � wm.•rn , a o t M I(3) 7/5•'-9X4- LG HEX HD BOLTS. -)1 -9 174 NUTS (GRADE 8) WITH LOCI[ WASHERS � FRekAP I'Rf1NT 4 1 114"� T 3/4" 5/8" DIA. CALV. STEEL ROD "l I ! 4 3/4" = 1 374" 5/8-11" UNC THD. I�-I PLAN OF GRATE & FRAME SLCTIUN " USE 4V'TH THE STANDARD SPECIFICATIONS CNi Y www-EurhamRc.gov 1 $ 6 9 crtr�c,eo�ew€ M CUSTOM STAMP ON DRAINAGE STRUCTURES (1) DROP HANDLE W/ 5/8-11" DETN 1533.1 ti 'I 21533.1-1 RJune20;7 z oT2 - City of Durham, N Voica [9191 `904326 C7 0 U1 = ZW ^ SECTION (2) SS NYLOK HEX NUTS AND I- 5" IT OF COVER NARROW WASHERS FRAME ENDS DROP HANDLE SECTION _ ~ Z Lu NOTES: OUTSIDE OF ALL 1. Est. Weight: 298 lbs (both pieces). CONSTRUCTION INTO BOX { NoTGSGaie 2. Material: ductile iron conforming to ASTM A536 5.50/6.00 ;' 2'-1" so. 3. Castings to be uncoated. FORMED INVERT DETAIL _111-I I1 -ill -I I1 -i+l l� li-.11-��1 4. Castings to be made of recycled materials, 75% post A crtr of peulG-hE consumer waste. 5Q-I @ 8" 5. Logo and all lettering to be clean, crisp, and clearly legible. dune, 207177 1 1 1 ar 6, 5/8" raised lettering (CITY OF DURHAM FOR RAIN WATER ONLY 6.50/6.75 }AL, - DRAINS TO DRINKING WATER). - 1.50 2.50 r 7. Use grade 8 bolts only for bolting together. SECTION C -C 8. For casting specifications see defgil 638.01. ❑ U R H A M '� Dept. of Warks ity o f Durham, N C Hall P C 101 City Hall Plaza w VOWS [919} 5Bg4S20 2'-0" 50. I Durham.N.C. 27101 USE WITH THE STANDARD Si:L _'•.IATIC]N8 ONLY www.d"rhammgar i's a6.9 TYPE I CATCH BASIN WITH CURB INLET Not Not To Scale SCALEIN ,633-03 633-0 DATE .lune, 2077 SHrEETR 2 d 2 CATCH BASIN COVER STAMP 1] U R HA M Dept. of Public WorksVoice (9 19) SH4325 101 City Hall Plaza City of Durham, N C PLAN OF GRATE & FRAME SLCTIUN Durham, N.C. 2.7701 USE 4V'TH THE STANDARD SPECIFICATIONS CNi Y www-EurhamRc.gov 1 $ 6 9 crtr�c,eo�ew€ STORM CUSTOM STAMP ON DRAINAGE STRUCTURES NOSCALE I ro scare DETN 1533.1 ti 'I 21533.1-1 RJune20;7 z oT2 - CASTING SPECIFICATIONS: 1 , Gray iron conforming to ASTM A48 Class 35B, 2. Ductile iron conforming to ASTM A536 grade 80-55-06. 3. Castings to be made of recycled materials, 75% consumer waste. 4. Castings shall come from a NCDOT approved foundry. 9 PP . Y 5. Castings shall be uniform qualify, free from sand holes, gas holes, shrinkage, cracks, and other surface defects. Castings shall be reasonably smooth and well cleaned by shot blasting. Surfaces of the castings shall be free from burned on sand and shall be reasonably smooth. Runners, risers, fins and other cast -on pieces shall be removed from castings and such areas shall be ground smooth. Bearing surfaces between manhole rings and covers shall be cast or machined with such precision that uniform bearing shall be provided throughout the perimeter area of contact. Nominally, castings dimensional tolerances shall be +/- 1/16" per foot. All casting weights are average and approximate values may vary 6. Traffic service castings shall meet or exceed the latest standards of AASHTO M306. The casting shall be tested on o suitable and calibrated load testing machine and the casting shall hold ❑ 40,040 pound proof load for one minute without experiencing any cracks or detrimental permanent deformation. Ductile iron conforming to ASTM A536 grade 80-55-06. 7. Each casting shop be identifiable and Shaw, ata minimum, the following: name of the producing foundry, country of manufacture, ASTM material designation, recycle symbol, individual part number and cast or heat date. Castings shall include all lettering as shown on the specification drawings. DURHAM Dept. of Public Works Cit of Durham, N C Voice (91916 04326 101 City Hall Plaza Y Durham. N.C. 21701 USE WITH 1'1+E 5TANDARD 5PEL;IFIL.AT;'jN3 ON_Y www-durhamnc.gov CATCH BASINS SCALE: q NOI To SCale 26f=. 02 1 $ 6 9 CASTING SPECIFICATIONS REVISLDN DATE 5t+EETx dune, 2077 1 of 1 PLACE ,#57 STONE AROUND OUTSIDE OF SECTION A -A SLOPE OF HANNEL A wN ON PL 5" PIPE n.D 6" to be a minimum of 3000 PSI at 28 days concrete. PLAN OF GRATE & FRAME SLCTIUN MIN. VARIES MIN. structure with stone around pipe. �4" A DURHAM NOTE 2 Dept. of Public Works City of Durham, N Voica [9191 `904326 C7 0 U1 = ZW ^ • INSTALL PRECAST ENDWALLs WITH WINGS AND PAY GROUT AROUA 101 City Hall Plaza Durham, N.C. 27701 USE W'TH THE STANDARD 3PEEIFICATIGNS ONLY www1durhamnc.9ov _ ~ Z Lu 11 OUTSIDE OF ALL PIPE CONSTRUCTION INTO BOX FOR GRADE 60 AND WELDED WIRE FABRIC CDNFORMING NoTGSGaie SLOPE SHELI 5.50/6.00 1 8 6 9 2'-1" so. 1'P/FT MAX, FORMED INVERT DETAIL _111-I I1 -ill -I I1 -i+l l� li-.11-��1 57 STgNE A crtr of peulG-hE PRECAST BOA( 5Q-I @ 8" INOTES - PLACE y57 STONE AROUND OUTSIDE OF PIPE AT BOX SECTION B -B il`II. B CONCRETE BRICK BOX 1. Invert to be a minimum of 3000 PSI at 28 days concrete. PLAN OF GRATE & FRAME SLCTIUN 2. All penstrations in boxes shall be inspected prior to backfilling structure with stone around pipe. �4" M7/8 DURHAM "1-1 Dept. of Public Works City of Durham, N Voica [9191 `904326 C7 0 U1 = ZW ^ • INSTALL PRECAST ENDWALLs WITH WINGS AND PAY W Q = 101 City Hall Plaza Durham, N.C. 27701 USE W'TH THE STANDARD 3PEEIFICATIGNS ONLY www1durhamnc.9ov _ ~ Z Lu 11 1 172" PIPE CONSTRUCTION INTO BOX FOR GRADE 60 AND WELDED WIRE FABRIC CDNFORMING NoTGSGaie 253901 5.50/6.00 1 8 6 9 2'-1" so. AND FORMED INVERT DETAIL 3.00/3.75 REVISION • PIPE TO BE GROUTED INTO HEADWALL AT JOB SITE BY crtr of peulG-hE D 5Q-I @ 8" 1.25/2.00 dune, 207177 1 1 1 ar SEAL A ISSUED FOR PERMIT 2019.04.05 REV.NO. DESCRIPTIONS DATE SEAL \\0\\\ 1111 CARS'''%, Ol�'1'q 028419 . 4/05/2019 .. Q ISOMETRIC VIEWS ' ISOMETRIC VIEW f�'z� fn f cr !2 ...f r n M t It 1/2" RA1SE4 _TTERIFIG SHALL BE LEAN, CRISP ANI? CLEARLY LEGIBLE SECTION PLAN OF GRATE & FRAME M M PLAN OF GRATE & FRAME SLCTIUN of GRATE WEIGHT OF GRATE- 132 LBS. x 7 Mu[� u} fly SECTION PLAN OF GRATE & FRAME , PLAN OF GRATE & FRAME SLCTIUN of GRATE WEIGHT OF GRATE- 132 LBS. x 7 WEIGHT OF GRATE= 125 LBS of GRATE u} rV �4" M7/8 _I "1-1 STANDARDS: 838.01, 838.11, 838.21, 838.27, 838.33, LL J K H Z 838.39, 638.51, 836.57, 838.63 AND 838.69. C7 0 U1 = ZW ^ • INSTALL PRECAST ENDWALLs WITH WINGS AND PAY W Q = SECTION PLAN OF GRATE & FRAME , PLAN OF GRATE & FRAME SLCTIUN of GRATE WEIGHT OF GRATE- 132 LBS. x 7 WEIGHT OF GRATE= 125 LBS of GRATE 23 11/16' ■ �4" M7/8 _I "1-1 STANDARDS: 838.01, 838.11, 838.21, 838.27, 838.33, LL J K H Z 838.39, 638.51, 836.57, 838.63 AND 838.69. C7 0 U1 = ZW ^ • INSTALL PRECAST ENDWALLs WITH WINGS AND PAY W Q = FOR IN ACCORDANCE WITH SPECIFICATION SECTION 83B. -1 3/16" * USE 4000 PSI CONCRETE. _ ~ Z Lu ' PROVIDE ALL REINFORCING STEEL WHICH MEETS ASTM A615 1 172" @ 8" p Uj FOR GRADE 60 AND WELDED WIRE FABRIC CDNFORMING 1 f SECTION of GRATE 5.50/6.00 T SECTION of GRATE 2'-1" so. CL ti OSHA STANDARD 1926.704. 3.00/3.75 r- -, • PIPE TO BE GROUTED INTO HEADWALL AT JOB SITE BY ' D 5Q-I @ 8" 1.25/2.00 ' ALL ELEMENTS PRECAST TO MEET ASTM C913. 1.5012.50 I 6.50/6.75 }AL, #s - 1.50 2.50 r 4.00 4.75 1 FRAME Is ■ l T I I V-8 /4" So } 2.5 lL[ 2'-0" 50. I REVERSIBLE ; I 1~ 2'-1 7/8" 50. 11 COVER TO SURFACE cc @ 8" TO INCREASE THIS BAR SIZE AS NEEDED. 5,00/6.00 LLQ o O 5.2515.75 11.50111.75 N #5@ 8" 3.2514.50 6.00/6.75 3.25/3.50 6.0016.75 12.00113.25 4.0 05 @ 8" 3.50/4.50 6.50/7.00 N SECTION of FRAME ' SECTION of FRAME 292 SO. IN. OPENING AREA ■ 2E8 50. IN_ OPENING ARCA WEIGH OF FRAME- 120 LBS. 3,2514.00 WEIGHT OF FRAME- 65 LBS TRAFFIC BEARING( 5.0 NON -TRAFFIC BEARING @ 8" 4.50/5.00 7.0018.50 24"x24" GRATE, & FRAME 7.2519.25 24"x24" GRATE, & FRAMF NOTES: 0.092 @ 8" 1. See general notes de#ail 638-.01 and Casting Specifications deicil 638.02. DURi'AV' Dept of Public Works City T01 City Hall Plaza of Durham] N C Voice [9181560-4326 @ 8" 4.50/5.00 Durham. N.C. 27701 USE WITH THE STANDARD SPECIFICATIONS ONLY www_durhamnc.gov 3.25/4.00 7.7519.25 24"' x 24" GRATE and FRAME NottToscale 2633.04 1 s 6 (TRAFFIC & NON -TRAFFIC BEARING) R; zo 7'� �,aT"; carr III NCl1d%.E 5'-6" 5'-6" 0.560 0.560 - W1 (FT,) ELEVATION W2 (FT. 8" D.C.ITYP.1 REFER TO CHART FOR BAR SIZE PLAN 49" NFK11\4& CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com D E„ I L 0 I H1 - I- - . 6„ f 8" D.C.(TYP.) REFER TO CHART FOR BAR SIZE SIDE Drainage Structures Notes; 1. Mortar joints 1/2" +/_ 1/8" thick. 2. Use class "A" concrete (3,000 PSI) throughout. 3. Use forms for construction of floor slab. 4. Deduct from pipe(s) for total Cu. Yds. Of brick masonry. 5. Use #4 bar dowels at 12" D.C. 6. Use brick or concrete block which complies with the requirements of NCDOT Section 840 of the Standard and Specifications (latest revision), 7, Steps shall be installed in all catch basins over 3'-6" in depth at 15" O.C,. Depth shall be measured from the top of gutter to invert. Galvanized reinforced steel shall not be used for steps. See NCDOT standard drawing #840.66. 8. A concrete base pad per NCDOT standard drawing #840.00 shall be added for reinforced concrete pipes set at the floor slab. 9. Construct with pipe crowns matching. 10. Chomfer all exposed corners 11". 11. Boxes may be reinforced masonry, masonry, precast concrete or cast -in-place reinforced concrete. 12. Any non-slandarld box (non-standard meaning not shown in this manual), is lu be designed by a NC Professional Engineer and approved by the City Engineer. 13. For basins 8'-0" in depth or less use 8" thick walls. If depth of basin is over 8'-O wall thickness shall be 12" from bottom to 6'-0" in depth and 8" for the remaining depth of the basin. Basins over 12' in total depth shall be designed by a NC Professional Engineer and approved by fhe Cily engineer. Four inch walls are not allowed on drainage structures. Bottom slab on structures shall be reinforced when box depth exceeds 8 ft. All reinforced slabs to be designed H2O, detailed by a NC Professional Engineer and approved by the City engineer. 14_ Steps are to be PS1-PF os manufactured by M_ A_ Industries or an approved equal. Locate on non -pipe walls. Steps shall meet OSHA requirements and shall be stagger spaced at 15" o/c. f5. Mortar in masonry boxes is to be type M. 16. Clay brick structures are not to be allowed. 17. Concrete pipe is to be minimum class III. 18. All cast -in-place or precast concrete drainage structures located in paved areas accessible to truck loadings to be designed to meet AASHTO HS 20-44 loading. See manufacturers details for wall, top and bottom thickness. 19. Inside of boxes shall allow for 6" of clearance on both sides of pipe. The dimension shown on the structures in this manual are minimum dimensions. For boxes with greater dimensions, either corbel walls, add a reinforced concrete top slab or lengthen box by adding additional grates & frames, Tap and bottom slabs to be designed by NC Professional Engineer and approved by the City Engineer for H2O loading, 20. Maximum horizontal span of an 8" thick wall shall not exceed 8' for boxes of 8 feet or less in depth and 10 feet for boxes 12 feet or less in depth. NCPE to verify based on soil type, ground water elevation and surcharge conditions, DURHAM D■pLofPublic Works ��#of Durham, INC Voica(919155843,26 101 City Hall Plaza City Durham. N.C. 21701 USE WITH THE gTANr...I-.: ... , ...:. .•v www-durhamnc.gor DRAINAGE STRUCTURES SCALE Y NOl ra scale 2638038,, 07 1 S 6 9 NOTES REV 161 DN DATE SHEET W. nrrMFEm4:xE' JLim. 2017 1 of 7 W a cc LU a CC � n C1 v < ~ CIN U3 V = LU L17 Z COL cc SI f1 v LL ET 1 OFF 1 PLAN Z EASTo -AN oo�WDRXSoo�io a� x 7 < NOTES: d MINIMUM MIN. IMAX. THIS PRECAST ENDWALL MAY BE USED FOR THE FOLLOWINGrZrcc �? STANDARDS: 838.01, 838.11, 838.21, 838.27, 838.33, LL J K H Z 838.39, 638.51, 836.57, 838.63 AND 838.69. C7 0 U1 = ZW ^ • INSTALL PRECAST ENDWALLs WITH WINGS AND PAY W Q = FOR IN ACCORDANCE WITH SPECIFICATION SECTION 83B. or <D * USE 4000 PSI CONCRETE. _ ~ Z Lu ' PROVIDE ALL REINFORCING STEEL WHICH MEETS ASTM A615 CO I- LL d J @ 8" p Uj FOR GRADE 60 AND WELDED WIRE FABRIC CDNFORMING O CC TO ASTM A185 WITH 2" MIH. CLEARANCE. 5.50/6.00 " PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH 05 CL ti OSHA STANDARD 1926.704. 3.00/3.75 W O • PIPE TO BE GROUTED INTO HEADWALL AT JOB SITE BY ' D CONTRACTOR @ 8" 1.25/2.00 ' ALL ELEMENTS PRECAST TO MEET ASTM C913. 1.5012.50 " WELDED WIRE FABRIC MAY BE SUBSTITUTED FOR REBAR 6.50/6.75 AS LONG AS THE SAME AREA OF STEEL IS PROVIDED. #s " CHAMFER ALL CORNERS 1" OR HAVE A RADIUS OF 1". 1.50 2.50 r 4.00 4.75 1 1.75 2.50 / 4.00 4.25 1 7.50 8.25 / 2.5 lL[ @ 8" NOTE: THEMINIMUM BAR SIZE SHALL 8E #5 GARS 4.00/6.00 ht: 4.5015.50 AT 8" CTS. THE. CONTRACTOR WILL NAVE THE OPTION COVER TO SURFACE cc @ 8" TO INCREASE THIS BAR SIZE AS NEEDED. 5,00/6.00 LLQ o O W a cc LU a CC � n C1 v < ~ CIN U3 V = LU L17 Z COL cc SI f1 v LL ET 1 OFF 1 PLAN APRIL 5, 2019 EASTo -AN oo�WDRXSoo�io ENDWALL DIMENSIONS x 7 DJB DESIGNED FT. MINIMUM MIN. IMAX. MIN./MAX. MIN./MAX. MIN./MAX. MIN./MAX. PIPE DIA. BAR SIZE H1(FT.) H2(FT,) D (FT.) W1 W2 1.0 #5 @ 8" 1.25/2.00 2.0013.75 1.25/1.75 3.0013.75 5.50/6.00 1.25 05 @ 8" 1.25/2.00 3.00/3.75 1.2512.00 3.5013.75 6.5016.75 1.50 #5 @ 8" 1.25/2.00 3.00/4.25 1.5012.50 3.5013.75 6.50/6.75 2.a #s @ a 1.50 2.50 r 4.00 4.75 1 1.75 2.50 / 4.00 4.25 1 7.50 8.25 / 2.5 05 @ 8" 2.5013.50 4.00/6.00 2,0013.00 4.5015.50 10.00/11.50 COVER TO SURFACE 2'-9" @ 8" 3.00/3.50 5,00/6.00 2.7513.50 5.2515.75 11.50111.75 3.5 #5@ 8" 3.2514.50 6.00/6.75 3.25/3.50 6.0016.75 12.00113.25 4.0 05 @ 8" 3.50/4.50 6.50/7.00 3,25/3.50 6.5016.75 13.00113.25 4.5 05 [a 8" 4.00/5.00 6,50/8.50 3,2514.00 7,0019.25 13.50/15.75 5.0 #5 @ 8" 4.50/5.00 7.0018.50 3.2514.00 7.2519.25 13.75/15.75 1.660 0.092 @ 8" 4.50/5.00 7.50/8.50 3.25/4.00 7.2519.25 14.00/15.75 6.0 #5 @ 8" 4.50/5.00 7,50/8.50 3.25/4.00 7.7519.25 14.75116.75 W a cc LU a CC � n C1 v < ~ CIN U3 V = LU L17 Z COL cc SI f1 v LL ET 1 OFF 1 PLAN 2 x 3 YARD INLET CATCH BASIN STAMP ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ f ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ i ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ i ■ ■ ■ • i ■ ■ ■ ■ f ■ ■ ■ ■ ■ ■ ■ . ■ ■ • " . DUMP NO WASTE'. DRAINS TO WATERWAYS £AST JORDAN IRON WORKS MADE IN VSA MO/DA/YR 3/4" LETTERING DROP INLET HOOD STAMP DURHAM Dept. Of Public Warks City of Durham N C voioet919)S One 101 City Hall Plaza 3 Durham. N.C. 27701 VSE W:TH THE 5TANDARD 5PEI.IFICATIONS ONLY www-Eurh=nc.gov CUSTOM STAMP ON SCALE: 1 Nol Ta Scale 21533. -1 y 'I STORM DRAINAGE STRUCTURES REV 20;x ' 2 1669 IL MANHOLE f 6"7C APRIL 5, 2019 EASTo -AN oo�WDRXSoo�io IRON x 7 DJB DESIGNED DJB o�o�0000�c000000 - REINFORCEMENT BAAS "A" D r- oi, DEDUCTIONS FOR ONE PPE CU.YDS. _ 2 x 3 YARD INLET CATCH BASIN STAMP ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ f ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ i ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ i ■ ■ ■ • i ■ ■ ■ ■ f ■ ■ ■ ■ ■ ■ ■ . ■ ■ • " . DUMP NO WASTE'. DRAINS TO WATERWAYS £AST JORDAN IRON WORKS MADE IN VSA MO/DA/YR 3/4" LETTERING DROP INLET HOOD STAMP DURHAM Dept. Of Public Warks City of Durham N C voioet919)S One 101 City Hall Plaza 3 Durham. N.C. 27701 VSE W:TH THE 5TANDARD 5PEI.IFICATIONS ONLY www-Eurh=nc.gov CUSTOM STAMP ON SCALE: 1 Nol Ta Scale 21533. -1 y 'I STORM DRAINAGE STRUCTURES REV 20;x ' 2 1669 IL MANHOLE f 6"7C APRIL 5, 2019 E 07473-0001 x 7 DJB DESIGNED DJB CHECKED - REINFORCEMENT BAAS "A" D r- oi, DEDUCTIONS FOR ONE PPE CU.YDS. _ A B H NO. m w W O TOP SLAB f WALL? FT. OF ✓f. LBS. REINF CU, YIDS. MIN. "H" C' 8, R. C. A 2'-01' 2'-0" 12 2'-911 3'-0" T-0" 0.167 0.187 0.1$5 22 0.75❑ 0.015 6.024 16" 2'•3" 2'-3" SEE STANDARD 840.54 M C 3' 0" FOR MANHOLE COVER & FRAME Ji4 BARS "A" 3'•3" QPTIVNAL SPACED 6 0.204 24 C• TO 0 - BRICK MAY BE USED ❑.036 TO ADJUST FRAME 8 2'-6" COVER TO SURFACE 2'-9" ELEVATION MAX. 1' 3'-3" I a I -'- A I SECTION X -X B" "XS" EXP. JOINT P I SEE NOTE \ a1l I DOWEL SECTION Y -Y 6" E OR f: SECTION C -C OR D -D GENERAL NOTES: CHAMFER ALL EXPOSED CORNERS I". USE CLASS "B" CONCRETE THROUGHOUT. OPTIONAL CONSTRUCTION - MONOLITHIC POUR,2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTEfiS AS f1IRECTED BY THE ENGINEER. USE FORMS TO CONSTRUCT THE BOTTOM $LAB. IF REINFORCED CONCRETE PIPE IS SET IN BASE SLAB OF Box, ADD TO BASE AS SHOWN ON STANDARD NO. 840.x0. PROVIDE ALL JUNCTION BOXES OVER 3'-8" IN DEPTH WITH STEPS 12" ON CENTERS IN ACCORDANCE WITH STD. NO. 840.66. ADJUST THE STEEL, CONCRETE AND BRICK MASONRY QUANTITIES TO INCLUDE THE ADDITION OF THE MANHOLE (I.E. DIAGONAL BARS SHORTENED AROUND OPENING IN TOP SLAB, ADDITIONAL VARIABLE HEIGHT BRICK VASONRY, OPENING IN TDP SLAB.) MAN. DEPTH OF THIS STRIJGTURE PROM TOP OF 31)TTOM SLAB TO TOP ELEVATION IS 12 FEET, r k4 BAR '1 DOWEL 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA STORM DRAINAGE DETAILS DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 01MENSIONS AND QUANTITIES FOR CONCRETE JUNCTIOM 80Xr=S DJB DESIGNED DJB CHECKED DIMENSIONS QF BOX AND PIP£ PIPE SPAN WIDTH HEIGHT REINFORCEMENT BAAS "A" TOP SLAB DIMENSIONS CUBIC VARDS IN BOX TOTAL OUAliTITTE5 BOX AND SLABS DEDUCTIONS FOR ONE PPE CU.YDS. D A B H NO. LENGTH E F TOP SLAB BOTTOM SLAB WALL? FT. OF ✓f. LBS. REINF CU, YIDS. MIN. "H" C' 8, R. C. 12" 2'-01' 2'-0" 12 2'-911 3'-0" T-0" 0.167 0.187 0.1$5 22 0.75❑ 0.015 6.024 16" 2'•3" 2'-3" 2'-6" 12 3' 0" 3'•3" 3'•3" 0.196 0.196 0.204 24 0.902 0.023 ❑.036 18" 2'-6" 2'-e" 2'-9" 14 3'-3" 3'-6" 3'-e" 0.227 D.227 0.222 30 1.065 0.033 0.949 24" 3'-O" 3'-0" 3'-3" 16 3'-9" 4'-0" 4'-0" 0.296 0.296 0.259 40 1.434 1 0.059 0.465 30" 3'-6" 3'-8" 3'-9" 18 4'-3" 4'-6" 4'-6" 0.375 0.375 0.296 51 1.660 0.092 0.127 36" 4'-0" 4'-0" 4'-3" 20 4'-9" 5'-0" 5'-0" 0.463 0.463 0.333 64 2.341 0.132 0.178 42" 4'-6" 4'-6" 4'-9" 22 5'-3" 5'-6" 5'-6" 0.560 0.560 0.370 77 2.878 4.180 0.243 48" 5'-4" 5'-4" 5'-3" 26 8'-3" 6'-4" 6'-4" 0.743 0.743 0.407 111 3.623 0.235 0.317 54" 5'•10" 5'-10" 5'•9" 2B 0'•7" 6'-10" 6'-10" 0.865 0.865 0.444 129 4.283 0.297 0.401 60" 6'-6" 6'-6" W-3" P 30 7'-3" 7'-6" 7'-6" 1.042 1.042 0.481 145 5.096 5.367 0.495 66" 7'-1" 7'-1" 6'-9" 1 32 1 V-10" 1 8'-1" I W-1" 1 1.210 1.210 0.518 169 1 5.917 1 0.444 1 0.589 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA STORM DRAINAGE DETAILS DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 DRAWN DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML SCALE HORIZONTAL: N/A VERTICAL: N/A Z a U1 �} ¢4 HccC3 LL _J Z Op(0m: Q Z LL S d�cr 0 LUH O6(!?cc Z H (L � H Lu in OW u - C3 m J Z O Lu v Z H I� Q a - cc O _ IL) J T4 or x Z in v Z I- 11J C ~ CO LULU [V � 2 � Qv 0 V CL MEET 1 OF 1 840.31 M&C FILE NUMBER D2.0 DRAWING NUMBER D2.0 'STATUS: REVISION NOT FOR CONSTRUCTION A ISSUED FOR REVIEW ONLY GENERAL NOTES: USE CLASS "S" CONCRETE THROUGHOUT. PROVIDE ALL CATCH BASINS OVER V-8" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH ETC. DRAWING 640.88. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR 04 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER, USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD 70 SLAB AS SHOWN ON STO. NO. 840.00. USE TYPE "E", "F" AND "G" ORATES UNLESS OTHERWISE INDICATED. FOR 8'•❑" IN HEIGHT OR LESS USE 6" WALLS AND BOTTOM SLAB. OVER 8'-❑" TO 16'-0' IN HEIGHT USE 8" WALLS AND BOTTOM SLAB. ADJUST QUANTITIES ACCORDINGLY. CONSTRUCT WITH PIPE CROWNS MATCHING. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. SECTION Y -Y RISER HT. VARIES 7 n 6,. •9• s8 WHERE 30" TO 36" PIPE IS USED RISER HT. VARIES �# A WHERE 42" TO 54" PIPE IS MED DETAIL SHOWING METHOD OF RISER CONSTRUCTION SECTION x -x �C �I SECTION J -J WHERE 30" TO 36" PIPE IS USED SEE NOTE Z O to Q d � cc LLJartiZ CD 0 m: LU =x ¢U=UiU-r-r F CO-LL0� 0 En z it CLF_ 1 1 ' wow L DETAIL SHOWING TYPES OF GRATES USE ACCORDING TO WATER FLOW. -TYPE "Gr' TYPE: "E" tYPE "F„ - WATER FLOW SAG WATER FLOW WATER FLOW ; SAG = WATER FLOW TYPE "F" TYPE "E" TYPE "G" P RAISED FLOW ARROW 2 "�{ ;6" HIGH I� 1 " J Zw o. 1112 11 W, 11/2++ 100 2'-113$ T'g of SECTION A -A TYPE - F PLAN DIMENSIONS OF BOX 8 PIPE z o(n RAISED FLOW ARROW r6++ HIGH 2-U0 �; A a E •e. = pzprg/ 0 m L ij e' g _,•:I -er DEDUCTIONS PIPE C.M. R.C. 12" i"a1, cnF_ a - = 4 F' amaw 24" Qpw¢ > 6 d imw 2'-0"3'-6" LL¢cc~=�z�co�LL0�iPLAN 0,092 0.127 la m i1r a'• 0.015 '' 75" 3'-0" _ LL D �oN<Z � V 6ALLAST 0.235 �/>aLO ' O.D36 9 -❑"2'-2"3'-3" < V = CC 35"IrINI TR 98.3"IYAK1 - a z SECTION M -NI W - WHERE 42" TO 54" PIPE IS USED } 1z iV v r 0.887 0.033 Q SIDE 3'-0"2'-2"3'-9" G 2 ORANGE & 2 WHITECOVERING ENTIRE OUTSIDE d v O L DETAIL SHOWING TYPES OF GRATES USE ACCORDING TO WATER FLOW. -TYPE "Gr' TYPE: "E" tYPE "F„ - WATER FLOW SAG WATER FLOW WATER FLOW ; SAG = WATER FLOW TYPE "F" TYPE "E" TYPE "G" P RAISED FLOW ARROW 2 "�{ ;6" HIGH I� 1 " J Zw o. 1112 11 W, 11/2++ 100 2'-113$ T'g of SECTION A -A TYPE - F PLAN q PLAN Cc HEET 1 OF 2 840.02 DIMENSIONS OF BOX 8 PIPE z o(n RAISED FLOW ARROW r6++ HIGH 2-U0 �; A USE OF SUCH STEPS.0 OF BOX AND PIPE SPAN WIDTH WIDTH SPAN A B C G •e. = pzprg/ 0 m L ij e' g _,•:I -er q PLAN Cc HEET 1 OF 2 840.02 142 2 v ION A -A DIMENSIONS OF BOX 8 PIPE z o(n RAISED FLOW ARROW r6++ HIGH 2-U0 23/<<Cr x U 0 cc USE OF SUCH STEPS.0 OF BOX AND PIPE SPAN WIDTH WIDTH SPAN A B C G "23CD LL -I CL "CD = pzprg/ BARS -U NO- LENGTH 0 m: wQZLL' BARS -W N0. LENGTH g ¢U<oCI]F-LLOw°= DEDUCTIONS PIPE C.M. R.C. 12" i"a1, cnF_ a - = 4 F' Z } n U W w 24" Qpw¢ > 0.059 0.085 d imw 2'-0"3'-6" 142 2 v ION A -A DIMENSIONS OF BOX 8 PIPE LL v In � � 2 RAISED FLOW ARROW r6++ HIGH 2-U0 PIPE SPAN WIDTH MIN. HEIGHTCONC. x U 0 cc USE OF SUCH STEPS.0 OF BOX AND PIPE SPAN WIDTH WIDTH SPAN A B C G MIN. HEIGHT H = pzprg/ BARS -U NO- LENGTH C3 W o z BARS -W N0. LENGTH TOTAL LRS. ¢QF- DEDUCTIONS PIPE C.M. R.C. 12" w � a - = 4 F' Z } n U W w ¢dam 11,2"R ¢ o i err r 2' 113/4 « r i7 LL �I 1 V2 to 1 1/2 rr %i 11 HEET 2 OF 2 NOTES:INSTALL ALL STEPS PROTRUDING 4" FROM INSIDE FACE OF STRUCTURE WALL. DIMENSIONS OF BOX 8 PIPE O (n STEPS DIFFERING IN DIMENSIONS, CONFIGURATION, OR MATERIALS FROM THOSE SHOWN MAY ALSO BE USED PROVIDED THE CONTRACTOR HAS FURNISHEDQ PIPE SPAN WIDTH MIN. HEIGHTCONC. THE ENGINEER WITH DETAILS OF THE PROPOSED STEPS AN1) HAS RECEIVED WRITTEN APPROVAL FROM THE ENGINEER FOR THE USE OF SUCH STEPS.0 OF BOX AND PIPE SPAN WIDTH WIDTH SPAN A B C G MIN. HEIGHT H COVER DIMENSION E F BARS -U NO- LENGTH BARS•V N0. LENGTH BARS -W N0. LENGTH TOTAL LRS. CU.YOS- CONC. IN BOX TOP BOTTOM TR" CMD•UNE SLAB SLAB K NIR IR7YE]GHT rl DEDUCTIONS PIPE C.M. R.C. 12" 3••4" 2'•2" 0.703 2'-9"❑.235 24" Qpw¢ 0.814 0.059 0.085 30"3'-0" 2'-0"3'-6" LL¢cc~=�z�co�LL0�iPLAN 0,092 0.127 0.772 0.015 0.D26 75" 3'-0" 2'-2" 3'-0" �oN<Z 6ALLAST 0.235 0.829 0023 O.D36 B"3' -❑"2'-2"3'-3" 35"IrINI TR 98.3"IYAK1 � OCIRCUMFERENTIAL ALTERNATE ORANGE & WHITE 0.235 0.887 0.033 O.U49 SIDE 3'-0"2'-2"3'-9" 2 ORANGE & 2 WHITECOVERING ENTIRE OUTSIDE PLAN SIDEELEVATION ELEVATIONCL 0-235 1.001 0.059 LL Uj 3'-4" 4 3 1'�2" 4'-p" IRON 1'�5" CAST IRON C3CAST z ELEVATION 3'�G" ELEVATION 0.123 0.321 �WN6 0.092 0. 27 1-2" 1ROUL RAYS oDDO CONTACT KITH THE &ARREL FUVNDE AND &VI -MT OUTER 1' 8" 4' "4 1' 11" 3 3' 9" 3 3'•9" 43 BAR GRQ 0.132 11/4 iia BAR GALV'D. zI,40 4' 5" 5`-3" 1' 5" 3'-2" 41'-8" 2 2'-71" 3 2'-11" W-fLLA 0.112 ❑.318 3-7380.180 0.243 aPOLYPROPYLENE2 W -O" 5'-9" 2' ❑•' 3'-2" PLAN SIDE PLASTIC 3 2'-71" 3 ELEVATION 35 SIDE 2 052 0.235 0.3]7 PLAN ELEVATION cc OCOMPOSITEREINFORCING 6,-7„ 6'-3„2`_7"3,_„ STEEL ,„ s 2._11,.32,_11,. USE THE TIRE BALLAST AS SPECIFIED BY THE MANUFACTURER. DO NOT PLACE BALLAST 2ON ELEVATION TOP OF THE DRUM.2- NOTE IF NECESSARY PLACE THE NAME OF THE AGENCY, CONTRACTOR, OR SUPPLIER ON NON-RETROREFLECTIVE #3 DEFORMED 12" DO NOT USE IN COLOR AND NOT STEEL ROD OVER 2" IN HEIGHT. SANITARY SEWER MANHOLES. 3• ALL DRUMS MUST BE LISTED ON THE DEPARTMENT'S APPROVED PRODUCT LIST. SECTION A -A ELEVATION 4. REFER TO THE STANDARD SPECIFICATIONS FOR ROADS ANO STRUCTURES FOR SEAL CARO�ES 0L0284194/05/2019 A ISSUED FOR PERMIT 2019.04.05 REV.NO. DESCRIPTIONS DATEREVISIONS #4 BARS "VEQ AL SPA ES 11 13R - nR1A -cN jy Q �GPLAN OF TOP SLAB SECTION S -S $" #B •'Yd" BARS#4BAR EQUAL SPACES__L#4 BARS " DOWEL SECTION R -R PLAN CURB AND GUTTER WITH CATCH BASIN ON STEEP GRADES TOP S„USE ON FLAT ELEV. EXPANSION JOINTGRADES 2�S AND UNDERDEPRESSED GUTTER LINE EXPANSION JOINT ELEVATION NORMAL CURB AND GUTTER ON LIGHT GRADES NORMAL GUTTER LINE E]fPANSION JOIkTBTOPUSE ON GRADES OVER 2% ELEV. DDEPRESSED GUTTER LINE EXPANSION JOINT MAX. 1, 0„ ELEVATION NORMAL CURB AND GUTTER ON STEEP GRADES ^" WEEP HOLES J Y PLAN WITH GRATE & FRAME REMOVED "UPING(INCIDENTAL) iP ELEVATION 840.16 FRAME - IATE A L SECTION X -X ISEE NOTE) ai 0.180 D.3$62.3870.2970.401 RISER HAS .228 CUBIC YARDS CF CONCRETE PER FOOT HEIGHT GENERALNOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL DROP INLETS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. 116E STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR 2" KEYWAY OR #4 BAA DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. 115E FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IFREINFORCED CgNGRET£ PIPEIS SE7 IN BgTTOM SLAB OF BOX, q40 TO SLAB AS SHOWN CN STD. NO. 840.00.CONSTRUCT WITH PIPE CROWNS HATCHING. SEE STANDARD DRAWING 840.25 FAR ATTACHMENT GF FRAMES AND GRATESNGT SHOWN. INSTALL 2"1YEEPHOLES AS DIRECTED BY THE ENGINEER. INSTALL STONE GRAINS, OF A MINIMUM CF1CUBIC F00T OF N0.78MSTCNE INA POROUS FABRIC SAG OR WRAP, AT EACHWEEP HOLE OAAS OIRECTE0 BY THE ENGINEER CHAMFER ALL EXPDSEQ CORNFRS 1 DRAWING NOT TOSCALE. 4 BAR '0 I Le DOWEL MAX. PIPE THIS SIDESECTION Y -Y DIMENSIONS AND QUANTITIES FOR DROP INLET(BASED ON MIN. HEIGHT, H) DIMENSIONS OF BOX 8 PIPE CUBIC YARDS IN BOX NINIMUV DIMENSIONS AND QUANTITIES FOR CONCRETE CATCH BASIH(BASED OH MIN. HEIGHT, H, WITH NO RISER)DIMENSIONS PIPE SPAN WIDTH MIN. HEIGHTCONC. Tor Is,D7AMFMNOT PIPE ❑ OF BOX AND PIPE SPAN WIDTH WIDTH SPAN A B C G MIN. HEIGHT H COVER DIMENSION E F BARS -U NO- LENGTH BARS•V N0. LENGTH BARS -W N0. LENGTH TOTAL LRS. CU.YOS- CONC. IN BOX TOP BOTTOM TR" CMD•UNE SLAB SLAB K NIR IR7YE]GHT rl DEDUCTIONS PIPE C.M. R.C. 12" 3••4" 2'•2" 0.703 2'-9"❑.235 24" 3 -0" 0.814 0.059 0.085 30"3'-0" 2'-0"3'-6" 0.222 0.222 0.925 0,092 0.127 0.772 0.015 0.D26 75" 3'-0" 2'-2" 3'-0" �oN<Z 6ALLAST 0.235 0.829 0023 O.D36 B"3' -❑"2'-2"3'-3" 35"IrINI TR 98.3"IYAK1 � OCIRCUMFERENTIAL ALTERNATE ORANGE & WHITE 0.235 0.887 0.033 O.U49 24" 3'-0"2'-2"3'-9" 2 ORANGE & 2 WHITECOVERING ENTIRE OUTSIDE 0-235 1.001 0.059 D.❑85 3'-4" 4 3 1'�2" 4'-p" 4 1'�5" 2 3'-9" 3 3'�G" 39 0.123 0.321 1.433 0.092 0. 27 1-2" 1ROUL RAYS oDDO CONTACT KITH THE &ARREL FUVNDE AND &VI -MT OUTER 1' 8" 4' "4 1' 11" 3 3' 9" 3 3'•9" 43 0.13581.714 0.132 0.178 ❑" 2'2" 4' 5" 5`-3" 1' 5" 3'-2" 41'-8" 2 2'-71" 3 2'-11" 32 0.112 ❑.318 3-7380.180 0.243 4E"'"2'-2" W -O" 5'-9" 2' ❑•' 3'-2" 4 2'-3" 3 2'-71" 3 2'-11" 35 ❑ 145 0 352 2 052 0.235 0.3]7 54"3,_0,. 2, 6,-7„ 6'-3„2`_7"3,_„ ,„ s 2._11,.32,_11,. USE THE TIRE BALLAST AS SPECIFIED BY THE MANUFACTURER. DO NOT PLACE BALLAST 2ON TOP OF THE DRUM.2- ^" WEEP HOLES J Y PLAN WITH GRATE & FRAME REMOVED "UPING(INCIDENTAL) iP ELEVATION 840.16 FRAME - IATE A L SECTION X -X ISEE NOTE) ai 0.180 D.3$62.3870.2970.401 RISER HAS .228 CUBIC YARDS CF CONCRETE PER FOOT HEIGHT GENERALNOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL DROP INLETS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. 116E STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR 2" KEYWAY OR #4 BAA DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. 115E FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IFREINFORCED CgNGRET£ PIPEIS SE7 IN BgTTOM SLAB OF BOX, q40 TO SLAB AS SHOWN CN STD. NO. 840.00.CONSTRUCT WITH PIPE CROWNS HATCHING. SEE STANDARD DRAWING 840.25 FAR ATTACHMENT GF FRAMES AND GRATESNGT SHOWN. INSTALL 2"1YEEPHOLES AS DIRECTED BY THE ENGINEER. INSTALL STONE GRAINS, OF A MINIMUM CF1CUBIC F00T OF N0.78MSTCNE INA POROUS FABRIC SAG OR WRAP, AT EACHWEEP HOLE OAAS OIRECTE0 BY THE ENGINEER CHAMFER ALL EXPDSEQ CORNFRS 1 DRAWING NOT TOSCALE. 4 BAR '0 I Le DOWEL MAX. PIPE THIS SIDESECTION Y -Y DIMENSIONS AND QUANTITIES FOR DROP INLET(BASED ON MIN. HEIGHT, H) DIMENSIONS OF BOX 8 PIPE CUBIC YARDS IN BOX DEDUCTIONS FOR ONE PIPE PIPE SPAN WIDTH MIN. HEIGHTCONC. Tor Is,D7AMFMNOT D H BOTTOM WALL PER flE.EA SLAB FT. HT. rOR YIRIYUY HEI6 TH C.M, R.C. 12" 3'-❑" 2' -❑"2'-O 0.222 0.222 0.592 0.015 ❑.026 15" 2'•3' 0.645 0.023 0.036 18"2'-6 0.703 0.033 0.049 24" 3 -0" 0.814 0.059 0.085 30"3'-0" 2'-0"3'-6" 0.222 0.222 0.925 0,092 0.127 A SOLID COVER SHOWN PERFORATED. PERFORATED AVAILABLE IF SPECIFIED. STATE USE OF SYSTEM ON COVER (I.E.: SEWER, STORM DRAIN, ELECTRICAL) 70P OF COVER 6 , B LBOTTOM OF COVER PLAN OF FRAME 111 2'-114TYPE #1 ALTERNATE 4'j1201/2�i� 2'- 91/4SECTION A-ATYPE #2 v &CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com PLAN OF COVER 11334 j�1.�4; 4of 'i05'sr1SECTION B -B MINIMUM WEIGHTS LBS. FRAME - 18D IL COVER - 120 TOTAL 300 Z a U,<4 �ccLLJ CL I-1 z CD m: ccQ=0ccf)�Zpwb a U)cc ow IrO z U_ Z a wwsa0cc Ln<�< Uj LU }= CJp Q Ocr HEET 2 OF 2 840.02 Z o U3 "}Q< r C)o LLJCLr"z oocoxL'"IQL'-x dUc1JHLL �w0 ccn ¢ °` CLCLw HLL Lu JZ Z LU daCc naF- LLI cn W z v a 0 x 'SHEET 1 OF 1 840.14 a v,"}QQ rz-1C=3 L-LL_IEr4= CD0U)xL'"IQL'-aUUCOHLL0�0 U) CCZ I -"_w O cl Wd LL CID LU >-_j a O <CL HEET 1 OF I 43" NOTE: USE TYPE "E", "F" AND "G" GRATE UNLESS OTHERWISE NOTED. PLAN FRAME,GRATE, & HOOD ASS'Y SECTION - AA jfL 33'SECTION - KK DEPRESSION 17`'%8of175/$[V SECTION G -G 2'- 81,41 96rr 2r1SECTION H -H L L A ALIGN FRAME WITH INSIDE EDGE OF WALL TO ALLOWFDR VERTICAL ADJUSTMENT WALL SECTIONSECTION - BB co I:1 LM FRAME PLAN 3' • OTIS 2D G., �2'-1111-6 R ROOD ELEVATION SECTION LL T SECTION - PP Nmyy10 K 1121i�1r,�rr Y2 1WH �t1rm-H H '-7%" 1'-7f811PLAN OF GRATING CAST IRON Z o U,F- P 11 P z~=LLC m:z oo(0 LLj LL ha2 LLCD JSECTION - MM CC O c"ri <w C3 SECTIO44N - NN z �i�IN��In i�o01Q< ¢ U o1 „O cc LU Qm H zcc +TN zSECTIOR - JJ LU LiO Cc LL CC Q Li SECTION - RR SHEET 1 OF 2 840.03 30 611 F-1-1 E EL a I I i F --` PLAN OF FRAME CAST IRON 811 3' 33� " '2' 34 �,e rr 1,134IT 2" 2'-2"2 21/8'03'-134 2'-13X4'r2' B" SECTION E -E SECTION F -F z o Uj1-}¢4 == LL -I CL F-1 z oowxLU dU=OOCI]HLLUJobcom°�CLw0 LD (AW DO z LL Q r�It z2r¢DO cW cnm QzLw�0 J2N F'HIILx LU LL HEET 1 OF 1 840.16 APRIL 5, 2019 MCE PROJ. # z DRAWN Tor Is,D7AMFMNOT DESIGNED �� CHECKED TD E wAm PROJ. MGR. GML D2.1 UM DEAMI Di ZORANGE PLAN FRAME,GRATE, & HOOD ASS'Y SECTION - AA jfL 33'SECTION - KK DEPRESSION 17`'%8of175/$[V SECTION G -G 2'- 81,41 96rr 2r1SECTION H -H L L A ALIGN FRAME WITH INSIDE EDGE OF WALL TO ALLOWFDR VERTICAL ADJUSTMENT WALL SECTIONSECTION - BB co I:1 LM FRAME PLAN 3' • OTIS 2D G., �2'-1111-6 R ROOD ELEVATION SECTION LL T SECTION - PP Nmyy10 K 1121i�1r,�rr Y2 1WH �t1rm-H H '-7%" 1'-7f811PLAN OF GRATING CAST IRON Z o U,F- P 11 P z~=LLC m:z oo(0 LLj LL ha2 LLCD JSECTION - MM CC O c"ri <w C3 SECTIO44N - NN z �i�IN��In i�o01Q< ¢ U o1 „O cc LU Qm H zcc +TN zSECTIOR - JJ LU LiO Cc LL CC Q Li SECTION - RR SHEET 1 OF 2 840.03 30 611 F-1-1 E EL a I I i F --` PLAN OF FRAME CAST IRON 811 3' 33� " '2' 34 �,e rr 1,134IT 2" 2'-2"2 21/8'03'-134 2'-13X4'r2' B" SECTION E -E SECTION F -F z o Uj1-}¢4 == LL -I CL F-1 z oowxLU dU=OOCI]HLLUJobcom°�CLw0 LD (AW DO z LL Q r�It z2r¢DO cW cnm QzLw�0 J2N F'HIILx LU LL HEET 1 OF 1 840.16 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA STORM DRAINAGE DETAILS DATE: APRIL 5, 2019 MCE PROJ. # z DRAWN Tor Is,D7AMFMNOT DESIGNED DJB CHECKED TD E wAm PROJ. MGR. GML D2.1 UM DEAMI Di ZORANGE ULTRA VIOLET "QC7STABILIZED IMPACT I=--ICLr"RESISTANT 0 C)coUj PLASTIC LL. HZLUTIRE �oN<Z 6ALLAST E101111 MI DINETER d H 35"IrINI TR 98.3"IYAK1 � OCIRCUMFERENTIAL ALTERNATE ORANGE & WHITE RETROREFLECTIVE STRIPES, 2 ORANGE & 2 WHITECOVERING ENTIRE OUTSIDE 2" MX. TYPICAL LL ALL RUBDER COLLAR6 x161 YE.LACK IR COLOR Z AND FREE OF ANY OMMED PAINTCGLU 1ROUL RAYS oDDO CONTACT KITH THE &ARREL FUVNDE AND &VI -MT OUTER EM wST LAY FLAT 9TiTn HMP SuRFAM ORIMMIS THAT UM TIRE LALLMn ARE NAMUFACTLBED -DDNDTIIBEOESI cc' IE 8+" TIM. TO R4"TAY.UaGENERAL NOTESOI- BALLASTING SHALL BE ACHIEVED BY THE SAND BAG, TIRE-SIDEWALL, OR PREFORMED WEIGHTED BASEMETHODS. USE THE TIRE BALLAST AS SPECIFIED BY THE MANUFACTURER. DO NOT PLACE BALLAST 2ON TOP OF THE DRUM.2- IF NECESSARY PLACE THE NAME OF THE AGENCY, CONTRACTOR, OR SUPPLIER ON NON-RETROREFLECTIVE DRUM SURFACES, SHOW THE LETTERS AND NUMBERS USING A NON-RETROREFLECTIVE COLOR AND NOT OVER 2" IN HEIGHT. 3• ALL DRUMS MUST BE LISTED ON THE DEPARTMENT'S APPROVED PRODUCT LIST. 4. REFER TO THE STANDARD SPECIFICATIONS FOR ROADS ANO STRUCTURES FOR ADDITIONAL INFORMATION. SHEET 1OF 1 1138.01 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA STORM DRAINAGE DETAILS DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 DRAWN DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML D2.1 N/A SCALE M&C FILE NUMBER D2.0 HORIZONTAL: DRAWING NUMBER N/A VERTICAL: D2.1 N/A STATUS: REVISION NOT FOR CONSTRUCTION A ISSUED FOR REVIEW ONLY I RIPARIAN BUFFER DO NOT DISTURB EXCEPT AS 4• AUTHORIZED BY THE COUNTY OF DURHAM NOTE.- SIGN SHALL BE PLACED ON METAL POSTS INSTALLED SECURELY IN THE GROUND. POSTS MUST EXTEND A MINIMUM OF THREE (3) FEET ABOVE THR GROUND AND BE SUNK AT LEAST TWO (2) FEET BELOW GROUND. RIPARIAN BUFFER SIGN NTS n -A U PLAN OF FRAME PLAN OF COVER TOP VIEW 1 1/4" LETTERING (RECCESSED) LETTERING/EMBLEM AS MANUFACTURED BY EAST JORDAN IRON WORKS OR EQUAL (2) 1 " DIA. VENT HOLES (2) OPEN PICKHOLES 1 1/4" LETTERING (RECCESSED) V-11 1/2" DIA 2 3/4" 1'-8" DIA SECTION OF COVER WEIGHT OF COVER= 125 LBS. 1 8 6 9 CITY OF MEDICINE SECTION OF FRAME WEIGHT OF FRAME= 153 LBS. PLAN OF COVER BOTTOM VIEW NOTES: 1. ALL LETTERING SHALL BE CLEAN, CRISP AND CLEARLY LEGIBLE. 2. SEE CASTING SPECIFICATIONS DETAIL SD -1.1. mr-wwumur-u u JUNCI m I I I I I� v II I I NEW 60" I I II �I I I RCP CULVERT I I SECTION REINFORCED CONCRETE JUNCTION BOX NTS SEAL SEAL CARO �0 S J�NFK112\4&CREED9� ve%80 L = 1730 Varsity Drive, Suite 500 028419 _ Raleigh, North Carolina 27606 4/05/2019 p Phone: (919)233-8091, Fax: (919)233-8031 F-1222 A ISSUED FOR PERMIT 2019.04.05 IREV.NO. DESCRIPTIONS DATE REVISIONS www.mckimcreed.com hi 18" RICE INV. IN=305.11 INV. IN=303.78 19.0' r 1 PROFILE REINFORCED CONCRETE JUNCTION BOX NTS 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA CULVERT DETAILS DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 DRAWN DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML SCALE HORIZONTAL: N/A VERTICAL: N/A M&C FILE NUMBER D2.0 DRAWING NUMBER D2.2 STATUS: REVISION NOT FOR CONSTRUCTION A ISSUED FOR REVIEW ONLY 00 LO I 2—D2.3 EL 2"-0" (300.00" [REF. CIVIL DWG.'s C.I.P. REINF. CONC. HEADWALL (REF. NOTE 5) T.O. CONIC. WALL EL 11'-6" (309.50') [TYP. U.N.O.] T.O. CONIC. FTG. EL 0'-0" (298.00') [REF. NOTES 1 & 8] 9'-7"x 6'-6" ALUM. PIPE ARCH ASSEMBLY (REF. NOTE 4) 44 :MEN 11 PIPE 58°45'5" 4—D2.3 E.O. C.I.P. REINF. CONIC. HEADWALL FTG. (TYP. U.N.O.) ,\O C5 1 - PLAN - HEADWALL No. 1 SCALE: 1/8" = 1'-0" NORTH REINF. CONC. HEADWALL PLAN NOTES: 1. REFERENCE ELEVATION FOR EACH OF THE STORMDRAIN SYSTEM's HEADWALL ASSEMBLIES IS THE HEADWALL FOOTING's T.O. CONC. ELEVATION. FOR EACH REFERENCE ELEVATION THE EQUIVALENT N.A.V.D.-88 ELEVATION HAS BEEN PROVIDED. REFERENCE CIVIL DWG.'s FOR ADDITIONAL INFORMATION & NOTE THE FOLLOWING: a.) HEADWALL No. 1: T.O. CONC. EL 0'-0" = EL 298'-0" (298.00'). 2. PREPARE THE SUBGRADE FOR HEADWALL ASSEMBLIES FOOTING's AS REQUIRED BY THE PROJECT SPECIFICATIONS AND THE CIVIL DRAWINGS. 3. GRADE ELEVATIONS ARE NOT SHOWN ON THE HEADWALL ASSEMBLY PLAN VIEW FOR CLARITY. REFERENCE THE CIVIL DRAWINGS FOR ADDITIONAL GRADING REQUIREMENTS & INFORMATION. 4. THE PIPE LAYOUT SHOWN REPRESENTS THE STORMDRAIN PIPING ASSEMBLY THROUGH THE HEADWALLS. THE ALUMINUM PIPE ARCH CULVERT ASSEMBLY TO BE DESIGNED BY CONTECH ENGINEERED SOLUTIONS, LLC. CONTRACTOR SHALL VERIFY THE PIPE DIMENSIONAL DATA SHOWN AND COORDINATE INFORMATION THIS DWG. AS REQUIRED w/ CONTECH VENDOR DWG.'s & THE PROJECT CIVIL DRAWINGS. 5. REFERENCE CIVIL DRAWINGS AS REQUIRED FOR LOCATION OF THE HEADWALL ASSEMBLIES WORK POINTS. 6. THE CAST—IN—PLACE REINFORCED CONCRETE CONSTRUCTION FOR THE HEADWALL, WINGWALL & FOOTING ASSEMBLIES SHALL ADHERE TO THE FOLLOWING: a.) CONCRETE SHALL HAVE A MINIMUM (28) DAY COMPRESSIVE STRENGTH = 4,000 PSI. b.) CEMENT MATERIAL SUPPLIED SHALL BE TYPE I OR TYPE II PORTLAND CEMENT THAT IS IN CONFORMANCE w/ ASTM C150. c.) FLY ASH THAT IS IN CONFORMANCE w/ ASTM C618, CLASS F MAY BE INCLUDED IN THE MIX. FLY ASH SHALL BE USED AS A PARTIAL CEMENT REPLACEMENT & NOT EXCEED 25% OF THE TOTAL CEMENTITIOUS CONTENT. d.) WATER SHALL BE IN CONFORMANCE w/ ASTM C94. e.) AIR ENTRAINING ADMIXTURE IS ALLOWED PROVIDED IT IS IN CONFORMANCE w/ ASTM C260. THE TOTAL AIR CONTENT REQUIRED IS 5% f 1%. f.) WATER REDUCING ADMIXTURE IS ALLOWED PROVIDED IT IS IN CONFORMANCE w/ ASTM C494, TYPE A OR D. g.) MAXIMUM SLUMP = 3" w/OUT WATER REDUCING ADMIXTURE & 6" w/ A WATER REDUCING ADMIXTURE. h.) WATER/CEMENT RATIO (w/c) = 0.45 MAXIMUM. Q FINISH REQUIREMENTS AS FOLLOWS: BACKFILLED SIDE OF WALL: ROUGH FORMED FINISH WHERE UNEXPOSED. TOP OF WALL: UNFORMED BUT SHALL BE TROWELED SMOOTH & LEVEL. EXPOSED SIDE OF WALL: OWNER MAY REQUIRE WALL TO BE CONSTRUCTED w/ A BLOCK STONE FORM LINER PATTERN OR OTHER "NON"—CONCRETE LOOKING TYPE OF FINISH OPTION. IF FORM LINER, VERIFY w/ OWNER FORM LINER MAY BE BY SPEC FORMLINERS, INC. w/ A "RE ASHLAR" %" MAX. DEPTH MEDIUM TO LARGE CUT ASHLAR STONE VENEER PATTERN OR AN APPROVED EQUAL. j.) ALL CONCRETE WORK IS TO BE MOISTURE CURED. k.) REINFORCING STEEL BARS FOR ALL CONCRETE WORK ARE TO GRADE 60 STEEL & IN CONFORMANCE w/ ASTM A615. 7. IF FORM LINER FINISH PATTERN TO BE INSTALLED, THE CONTRACTOR SHALL SUBMIT TO THE OWNER FOR APPROVAL, THE STONE VENEER/FORM LINER PATTERN PRIOR TO CONSTRUCTION OF THE HEADWALL ASSEMBLIES. CONTRACTOR TO NOTE THE TERM "CONSTRUCTION" INCLUDES ORDERING AND FABRICATION OF MATERIALS. 8. CONTRACTOR SHALL COORDINATE w/ OWNER REGARDING OBTAINING COPIES OF THE PROJECT GEOTECH REPORT PREPARED BY GeoTechnologies, INC. (PROJECT No. 1-14-0022—EB DTD. OCTOBER 29, 2014). BASED UPON SOIL BORINGS IN THE VICINITY OF THE CULVERT & HEADWALL POTENTIALLY THE CONTRACTOR MAY HAVE TO REMOVE PARTIALLY WEATHERED TO INSTALL CULVERT & HEADWALL ASSEMBLIES. 9. REFERENCE CIVIL DWG.'s FOR DRAINAGE REQUIREMENTS @ BACK FACE OF RETAINING WALL ASSEMBLY. SEAL A ISSUED FOR BIDDING ONLY - NOT FOR CONSTRUCTION 2019.01.16 REV.NO. DESCRIPTIONS DATE T.O. CONIC. WALL EL 11'-6" (309.50') [REF. PLAN] C.I.P. REINF. CONIC. HEADWALL (REF. PLAN) #5 VERT. REINF. BARS/DWL.'s (REF. SECTION 3—D2.3) [TYP. U.N.O.] T.O. CONIC. FTG. EL C-0" (298.00') [REF. PLAN] [REF. PLAN] 3" CLR. (TY A" (RAIN 1 [ TYP. ] #4 HORZ. REINF. BARS (REF. SECTION 3—D2.3) [TYP. U.N.O.] (3) ADD'L #4 HORZ. REINF. BA (SPA. @ 6" O.C. (MAX.) BTWN. REQ. 'D REINF. BARS) [TYP. T&B OF PIPE] MCE PROJ. # 07473-0001 DRAWN WFB DESIGNED WFB CHECKED DJB/WFB PROJ. MGR. GML i unnvCM Aklr' JnD Qnl T �J) AUU L #J VLK I. KLINr. BARS/DWL.'s (SPA. ® 4" O.C. BTWN. REQ.'D REINF. BARS/DWL.'S) [TYP. N. S. & F.S. OF PIPE] ASSEMBLIES AS REQ'D BY CL PIPE ALUM. PIPE ARCH MFG. (TYP.) [® PIPE PERIMETER AS SHOWN] 2 - ELEVATION - EXPOSED FACE OF HEADWALL No. 1 & ADD'L REINF. REQ.'s @ CULVERT OPNG. SCALE: 3/8" = 1'-0" CONT. 3/4" CHAMFER (EA. FACE) #4 INVERTED "U"—BARS SPA. ® 1'-0" O.C. 1'-6" I 11'-6>, 0/F C.I.P. REINF. CONIC. WALL (REF. "PLAN" NOTES 6.i & 7) [ TYP. ] [REF. PLAN] _I SEAL PRELIMINARY PLAN R BIDDING P ONLY 7'-n" /TVD LI\LI FL-m"'J 1'-6" FIELD COORD. FIN. GRADE EL's w/ CIVIL DWG.'s REQ.'s (TYP. EA. FACE) #5 VERT. BARS w/ STD. 90° HOOKS SPA. @ 8" O.C. (TYP. EA. FACE) #4 HORZ. BARS SPA. @ 1'-0" O.C. (TYP. EA. FACE) TIE HOOK TO SLAB BTM. REINF. (TYP.) #7 BARS SPA. ® 9" O.C. (TOP) #5 BARS SPA. @ 9" O.C. (BTM.) 3 - SECTION - THRU HEADWALL No. 1 SCALE: 1/2" = 1'-0" v 4e�NFKM&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com E.O. C.I.P. REINF. CONC. WALL (TYP.) #5 VERT. BARS (TYP. EA. FACE) [REF. SECTION 3—D2.31 #4 HORZ. BARS (TYP. EA. FACE) [REF. SECTION 3—D2.31 ZS � ALUM. PIPE ARCH ASSEMBLY (BY OTHERS) [COORD. w/ CIVIL DWG.'s FOR ADD'L INFO] [COAT ALL ALUM. SURFACES IN CONTACT w/ CONCRETE. USE BITUMASTIC (OR OTHER) IF REQ'D BY THE ALUM. PIPE ARCH MFG.] PIPE SKEWED WALL SECTION HORZ. WALL REINF. NOT SHOWN FOR CLARITY #5 DIAGONAL BAR 3" CLR. OF THE PIPE ARCH (EA. FACE) [2 N.S. & 2 F.S. AS SHOWN] O. O, 2'-8" 1'-6" (REF. PLAN) 3" CLR. i i ;c� ,U #4 HORZ. SKEW BARS SPA. @ V-0" O.C. & SPLICED w/ HORZ. BARS (FABRICATE w/ BEND AS REQ'D) [TYP. EA. FACE] 4 - DETAIL - REINF. @ WALL SKEW SCALE: 1/2" = 1'-0" 6 DAVIS DRIVE ENTRANCE AMENDMENT DURHAM COUNTY, NORTH CAROLINA CULVERT HEADWALL DETAILS CITY OF DURHAM PUBLIC WORKS DEPARTMENT APPROVED ENGINEERING DATE STORM WATER DATE TRANSPORTATION DATE DATE DATE DATE: JANUARY 16, 2019 MCE PROJ. # 07473-0001 DRAWN WFB DESIGNED WFB CHECKED DJB/WFB PROJ. MGR. GML SCALE HORIZONTAL: AS NOTED VERTICAL: N/A M&C FILE NUMBER S D401 DRAWING NUMBER D2.3 STATUS: REVISION ISSUED FOR BIDDING ONLY A NOT FOR CONSTRUCTION Sq, I I L g 9--7 APPROX. AREA = 49.9 SQ. FT. PLATE MAKE-UP HAUNCH: 2 @ 12N CROWN: 1 @ 9N TOTAL: 33N 1) MEASUREMENTS ARE TO THE INSIDE CRESTS OF THE CORRUGATIONS. 2) DIMENSIONS ARE SUBJECT TO MANUFACTURING TOLERANCES. 3) CIRCUM. PLATE LENGTHS ARE IN TERMS OF N, (N=9.625" OR 3 PI). 6-6" ALUMINUM STRUCTURAL PLATE PIPE ARCH RISE (OUTSIDE VIEW) L 9'-7" SPAN x 6'-6" RISE SCALE = 1:50 15"0, 2 s"xZ', 16GA CAP STUB with flange BRIDGE PLAN SCALE = 1:100 ALUMINUM STRUCTURAL PLATE PIPE ARCH, 0.150" GAGE 9'-7" SPAN x 6'-6" RISE 80'-4" BRIDGE PROFILE SCALE = 1:100 FLOW — FOR APPROVAL PRE-608521-010-ALSPPA-CON-B The d—i and inrormaaon shown on mis cawing is provided a to the pro- ownaq engineerand contractee by �o to h Engineered 5oiutiona « Conte Ip Neither,nis drawing, nor any part thereof, may be usetl, reproduced or 15"0, 2 3"xz', 16GA CAP w��I uT�Au° r r ALUMINUM STRUCTURAL PLATE PIPE ARCH PROJECT No.: 608521 STUB with Flange DATE: 12/20/2018 DESIGNED: DRAWN: ALUMINUM STRUCTURAL PLATE %J)"NTE PIPE ARCH, 0.150" GAGE Cuntech. Failurey d_I lyis doneat the u—p-inrityfb, Contech expresslydisclaimsanyliabllity or responsibility for 27'-10)/2" STRUCTURAL PLATE 9'-7" SPAN x 6-6" RISE XXX cc c JJC/JCC 4'-0" FLOW www.ContechES.com 75'-8" CHECKED: APPROVED: the drawing is based and actual field conditions are encountered ite work theca discrepancies m"at be reposed 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 CONTECH CONTRACT CROWN CENTERLINE = 78'-0" XXX 9,-7n SHEET NO.: pmgresses, to contech immediatery for ee-evamafinn of thedesign. cometh 33N SPAN — — — — — — — — — — — — — — — — — — — — — — eeepts no rabiiity for designs bnt on-b-ing, ineompiate or atemrormanonau redb omen. Ll 2 OF 5 80'-4" PLATE MAKE-UP HAUNCH: 2 @ 12N CROWN: 1 @ 9N TOTAL: 33N 1) MEASUREMENTS ARE TO THE INSIDE CRESTS OF THE CORRUGATIONS. 2) DIMENSIONS ARE SUBJECT TO MANUFACTURING TOLERANCES. 3) CIRCUM. PLATE LENGTHS ARE IN TERMS OF N, (N=9.625" OR 3 PI). 6-6" ALUMINUM STRUCTURAL PLATE PIPE ARCH RISE (OUTSIDE VIEW) L 9'-7" SPAN x 6'-6" RISE SCALE = 1:50 15"0, 2 s"xZ', 16GA CAP STUB with flange BRIDGE PLAN SCALE = 1:100 ALUMINUM STRUCTURAL PLATE PIPE ARCH, 0.150" GAGE 9'-7" SPAN x 6'-6" RISE 80'-4" BRIDGE PROFILE SCALE = 1:100 FLOW — FOR APPROVAL PRE-608521-010-ALSPPA-CON-B The d—i and inrormaaon shown on mis cawing is provided a to the pro- ownaq engineerand contractee by �o to h Engineered 5oiutiona « Conte Ip Neither,nis drawing, nor any part thereof, may be usetl, reproduced or ' H w��I uT�Au° r r ALUMINUM STRUCTURAL PLATE PIPE ARCH PROJECT No.: 608521 SEC. No.: 010 DATE: 12/20/2018 DESIGNED: DRAWN: modified In any manner without the prior written consent of %J)"NTE Cuntech. Failurey d_I lyis doneat the u—p-inrityfb, Contech expresslydisclaimsanyliabllity or responsibility for ENGINEERED SOWTIONS LLC STRUCTURAL PLATE 9'-7" SPAN X 6'-6" RISE XXX cc c JJC/JCC uch use. panties pp pun w If disc,,between the su lied informationu hich www.ContechES.com 8 DAVIS DRIVE — ENTRY DRIVE CHECKED: APPROVED: the drawing is based and actual field conditions are encountered ite work theca discrepancies m"at be reposed 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 CONTECH CONTRACT ZW M XXX 800-338-1122 513-645-7000 513-645-7993 FAX SHEET NO.: pmgresses, to contech immediatery for ee-evamafinn of thedesign. cometh 1 1/8/2019 REVS. PER REVIEW SCC DRAWING DURHAM, NC FMARKI DATE REVISION DESCRIPTION BY eeepts no rabiiity for designs bnt on-b-ing, ineompiate or atemrormanonau redb omen. 2 OF 5 Reference the most current version of ASTM D2487, Standard Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System), for comparable soil groups. FOR APPROVAL PRE-608521-010-ALSPPA-CON-B The design and information shown on this drawing is provided ce to the project owner, engineer and contractor by Contech Engineered Solutions LLC("Contech"). Neithertbis dreedmg, nor any part thereof, may be used, reproduced or modified inany mannerwithout the prior wnden consent of Contech. Faresslybure iWrnplyairn anyliadone atthe risk Contech expresslydiscleims any liability or responsibility for 1.0 STANDARDS AND DEFINITIONS 3.0 ASSEMBLY AND INSTALLATION TRENCH MINIMUM LIMITS OF COMPACTED SELECT EMBANKMENT I SEQ. No.: 010 DATE: 12/20/2018 DESIGNED: XXX DRAWN: JSC/SCC CONDITION ~ GRANULAR STRUCTURAL BACKFILL CONDITION www.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 1.1 STANDARDS - All standards refer to the current ASTM/AASHTO edition unless otherwise noted. 3.1 Bolts and nuts shall conform to the requirements of ASTM A307 and/or ASTM A449. The pipe arch structure shall be assembled in accordance with the plate layout APPROVED: XXX BACKFILL WIDTH BACKFILL WIDTH SHEET NO.: 3 oP 5 MARK DATE REVISION DESCRIPTION BY drawings provided by the Manufacturer and per the Manufacturer's recommendations. SEE NOTE #1 SEE NOTE #1 1.1.1 ASTM B746 "Corrugated Aluminum Alloy for Structural Plate for Field -Bolted Pipe, Pipe -Arches, and Arches." Bolts shall be tightened using an applied torque of between 100 and 150 ft. -lbs. (AASHTO Designation M-219). FILL MATERIAL ABOVE 3.2 The pipe arch structure shall be installed in accordance with the plans and MIN. COVER LEVEL J 1.1.2 AASHTO Standard Specification for Highway Bridges - Section 12 specifications, the Manufacturer's recommendations, and AASHTO Standard TRENCH Division I - Design, AASHTO LRFD Bridge Design Specifications Specification for Highway Bridges - Section 26 Division II - Construction/AASHTO WALL 5.5' MIN. COVER t] w w Section 12. LRFD Bridge Construction Specifications - Section 26. SEE NOTE #6 U d 1.1.3 AASHTO Standard Specification for Highway Bridges -Section 26 3.3 Trench excavation shall be made in embankment material that is structurally adequate. J Division II - Construction, AASHTO LRFD Bridge Construction The trench width shall be shown on the plans. Poor quality in situ embankment U LL Specifications - Section 26. ASTM B789, Standard Practice for material must be removed and replaced with suitable backfill as directed by the Engineer. ALSP 8" LOOSE LIFTS U Installing Corrugated Aluminum Structural Plate Pipe. PIPE w ww O m 3.4 Bedding preparation is critical to both structure performance and service life. ARCH co U> ¢ 1.2 DEFINITIONS The bed should be constructed to uniform line and grade to avoid distortions that may o a- create undesirable stresses in the structure and/or rapid deterioration of the roadway. _ NATURAL - _ �_ w 1.2.1 Owner - In these specifications the word "Owner" shall mean The bed should be free of rock formations, protruding stones, frozen lumps, roots, UNDISTURBEDL J U ARE -NC REGION No. 14 LLC. and other foreign matter that may cause unequal settlement. EMBANKMENT 1.2.2 Engineer - In these specifications the word "Engineer" shall 3.5 The foundation shall be designed to support the radial pressures exerted by the mean the Engineer of Record or Owner's designated engineering smaller radius portions of the pipe. The principal foundation support shall be provided in representative. the critical haunch area extending radially outward from the haunches. 1.2.3 Manufacturer- In these specifications the word "Manufacturer" 3.6 The structure shall be assembled in accordance with the Manufacturer's instructions. UNCOMPACTED BEDDING BLANKET shall mean CONTECH ENGINEERED SOLUTIONS 800-338-1122 All plates shall be unloaded and handled with reasonable care. Plates shall not be rolled SEE NOTE #2 SPAN TOM LAWSON. or dragged over gravel rock and shall be prevented from striking rock or other hard objects during placement in trench or on bedding. SECTION 1.2.4 Contractor - In these specifications the word "Contractor" shall mean the firm or corporation undertaking the execution of any 3.7 The structure shall be backfilled using clean well graded granular material that meets SELECT GRANULAR STRUCTURAL BACKFILL LIMITS. installation work under the terms of these specifications. the requirements for soil classifications A-1, A-24, A-2-5 or A-3 modified per AASHTO ADDITIONAL SELECT GRANULAR STRUCTURAL BACKFILL NOTES: M-145. See the structural plate backfill group classification table on this sheet. 1.2.5 Approved - In these specifications the word "approved" shall SATISFACTORY BACKFILL MATERIAL, PROPER PLACEMENT, AND COMPACTION ARE KEY FACTORS refer to the approval of the Engineer or his designated Backfill must be placed symmetrically on each side of the structure in 8 inch CRITICAL HAUNCH AREA BACKFILL ZONE, PRESSURE ON IN OBTAINING MAXIMUM STRENGTH AND STABILITY. representative. loose lifts. Each lift shall be compacted to a minimum of 90 percent density per SOIL GREATEST HERE. AASHTO T-180. THE BACKFILL MATERIAL SHOULD BE FREE OF ROCKS, FROZEN LUMPS, AND FOREIGN MATERIAL 1.2.6 As Directed - In these specifications the words "as directed" INITIAL LIFTS OVER THE CROWN OF STRUCTURE AS INDICATED THAT COULD CAUSE HARD SPOTS OR DECOMPOSE TO CREATE VOIDS. BACKFILL MATERIAL shall refer to the directions to the Contractor from the Owner 3.8 If tem construction vehicles are required to cross the structure, it is the P ora BY SHADED AREA TO BE COMPACTED TO REQUIRED DENSITY SHOULD BE WELL GRADED GRANULAR MATERIAL THAT MEETS THE REQUIREMENTS OF AASHTO or his designated representative. Contractor's responsibility to contact the Engineer to determine the amount of p y g WITH HAND OPERATED EQUIPMENT OR WITH LIGHTWEIGHT M-145 FOR SOIL CLASSIFICATIONS A-1, A-2-4, A-2-5 OR A-3 MODIFIED. SEE THE STRUCTURAL additional minimum cover necessary to handle the specific loading condition. (D-4 OR LIGHTER) EQUIPMENT. PLATE BACKFILL GROUP CLASSIFICATION TABLE ON THIS SHEET. BACKFILL MUST BE PLACED 2.0 GENERAL CONDITIONS SYMMETRICALLY ON EACH SIDE OF THE STRUCTURE IN 8" LOOSE LIFTS. EACH LIFT IS TO BE Normal highway traffic is not allowed to cross the structure until the structure has COMPACTED TO A MINIMUM OF 90% DENSITY PER AASHTO T-180. 2.1 Any installation guidance provided herein shall be endorsed by the been backfilled and paved. If the road is unpaved, cover allowance to accommodate NOTES: Engineer; discrepancies herein are governed by the Engineer's plans rutting shall be as directed by the Engineer. A HIGH PERCENTAGE OF SILT OR FINE SAND IN THE NATIVE SOILS SUGGESTS THE NEED FOR A and specifications. WELL GRADED GRANULAR BACKFILL MATERIAL TO PREVENT SOIL MIGRATION. IF THE PROPOSED 3.9 If an aluminum headwall and/or wingwall system is specified, the select granular 1. TRENCH WIDTH AND/OR SELECT BACKFILL WIDTH SHALL BE BACKFILL IS NOT A WELL GRADED GRANULAR MATERIAL, A NON -WOVEN GEOTEXTILE FILTER 2.2 The Contractor shall furnish all labor, material and equipment and structural backfill limits shall extend past the deadman anchor system. Contact the DETERMINED BY THE ENGINEER OF RECORD DEPENDING ON SITE FABRIC SHALL BE PLACED BETWEEN THE SELECT BACKFILL AND THE IN SITU MATERIAL. perform all work and services except those set out and furnished by the Engineer if stiff material or rock is encountered where the wingwalls and deadmen are SPECIFIC CONDITIONS. TYPICAL BACKFILL WIDTH IS 4 FEET FOR Owner, necessary to complete in a satisfactory manner the site STRUCTURE SPANS 14 FEET AND LESS, AND 6 FEET FOR STRUCTURE DURING BACKFILL, ONLY LIGHTWEIGHT TRACKED VEHICLES (D-4 OR LIGHTER) SHOULD BE NEAR preparation, excavation, filling, compaction, grading as shown on the to be installed. SPANS GREATER THAN 14 FEET. THE STRUCTURE AS FILL PROGRESSES ABOVE THE CROWN AND TO THE FINISHED GRADE. THE plans and as described therein. This work shall consist of all ENGINEER AND CONTRACTOR ARE CAUTIONED THAT THE MINIMUM COVER MAY NEED TO BE mobilization clearing and grading, grubbing, stripping, removal of 2. SHAPED BEDDING IS REQUIRED FOR A MINIMUM WIDTH OF SPAN/2. INCREASED TO HANDLE TEMPORARY CONSTRUCTION VEHICLE LOADS (HEAVIER THAN D-4). existing material unless otherwise stated, preparation of the land to be THE MINIMUM BEDDING THICKNESS SHALL BE 6 INCHES. filled, filling of the land, spreading and compaction of the fill, and all subsidiary work necessary to complete the grading of the cut and fill 3. ALL SELECT GRANULAR BACKFILL TO BE PLACED IN A BALANCED areas to conform with the lines, grades, slopes, and specifications. This FASHION IN THIN LIFTS (8" LOOSE TYPICALLY) AND COMPACTED TO 90 work is to be accomplished under the observation of the Owner or his PERCENT DENSITY PER AASHTO T-180. STRUCTURAL PLATE BACKFILL GROUP CLASSIFICATION, REFERENCE AASHTO M-145 designated representative. 4. COMPLETE AND REGULAR MONITORING OF THE PIPE ARCH GROUP CLASSIFICATION A -1-a A -1-b A-2-4 A-2-5 A-3 2,3 Prior to bidding the work, the Contractor shall examine, investigate and STRUCTURE IS NECESSARY DURING THE BACKFILL PROCESS TO AT Sieve Analysis Percent Passing inspect the construction site as to the nature and location of the work, LEAST THE MINIMUM COVER LEVEL. and the general and local conditions at the construction site, including No. 10 (2.000 mm) 50 max. ---- -- ---- ---- without limitation, the character of surface or subsurface conditions and 5. PREVENT DISTORTION OF SHAPE AS NECESSARY BY VARYING obstacles to be encountered on and around the construction site and COMPACTION METHODS AND EQUIPMENT. No. 40 (0.425 mm) 30 max. 50 max. -- ---- 51 max.* shall make such additional investigation as he may deem necessary for the planning and proper execution of the work. 6. PLACE SELECT GRANULAR BACKFILL IN RADIAL LIFTS AT No. 200 (0.075 mm) 15 max. 25 max. 35 max. 35 max. 10 max. APPROXIMATELY 85% OF THE RISE OF THE PIPE ARCH STRUCTURE. Atterberg Limits for Fraction Passing No. 40 (0.425 mm) If conditions other than those indicated are discovered by the Contractor, the Owner shall be notified immediately. The material which the Liquid Limits - -. 40 max. 41 min. Contractor believes to be a changed condition shall not be disturbed so that the owner can investigate the condition. Plasticity Index 6 max. I 6 max. 10 max. 10 max. Non Plastic Stone Fragment, Silty or Clayey coarse 2.4 The construction shall be performed under the direction of the Engineer. Usual Materials Gravel and Sand Gravel and Sand Sand *Modified from AASHTO M-145. 2.5 All aspects of the structure design and site layout including foundations, backfill, end treatments and necessary scour consideration shall be Fine beach sands, windblown sands, stream deposited sands, etc., exhibiting fine, rounded particles and typically performed by the Engineer. classified by AASHTO M-145 as A-3 Materials should not be used. Reference the most current version of ASTM D2487, Standard Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System), for comparable soil groups. FOR APPROVAL PRE-608521-010-ALSPPA-CON-B The design and information shown on this drawing is provided ce to the project owner, engineer and contractor by Contech Engineered Solutions LLC("Contech"). Neithertbis dreedmg, nor any part thereof, may be used, reproduced or modified inany mannerwithout the prior wnden consent of Contech. Faresslybure iWrnplyairn anyliadone atthe risk Contech expresslydiscleims any liability or responsibility for 0 ��_ NTECH�,� !���� ENGINEERED SOWiIONS LLC p A��I%uTCAV fir r jQ1F\� i `�iI STRUCTURALPLATE ALUMINUM STRUCTURAL PLATE PIPE ARCH 1 Ir r 11 9 -7 SPAN X 6 -6 RISE PROJECT No.: 608521 I SEQ. No.: 010 DATE: 12/20/2018 DESIGNED: XXX DRAWN: JSC/SCC ucn use. if discrepanciesbetween the supplied information u which pp upon the drawing is based and actual held conditions are encountered as site work progresses, these discrepancies must be reported "Conte to cometh �mmed�acery roti -evaluation or me design. comecn no liability for designs based on missing, incomplete or curate irmr-ti- supplied by others. www.ContechES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 CONTECH CONTRACT DRAWING 8 DAVIS DRIVE - ENTRY DRIVE DURHAM, NC CHECKED: ZWM APPROVED: XXX 1 1/8/2019 REVS. PER REVIEW SCC 800-338-1122 513-645-7000 513-645-7993 FAX SHEET NO.: 3 oP 5 MARK DATE REVISION DESCRIPTION BY CONCRETE HEADWALL/WINGWALL DISTANCE AS REQUIREE TO OUTSIDE EDGE OF FOOTINC VERTICAL SETTLEMENT JOINT y" BLACK INSULATION BOARD JOINT FILLER BACKED FOOTING END VIEW NOT TO SCALE AS DESIGNED BY THE ENGINEER, THE REINFORCED CONCRETE FOOTINGS MAY BE WIDENED AT THE ENDS OF THE STRUCTURE TO: • ACHIEVE AN ADEQUATE HEADWALL WIDTH. • MAINTAIN THE SETTLEMENT JOINT AT THE FOOTING / LEVELING PAD INTERSECTION. • COMBINE THE ABOVE WITH A WINGWALL INTERSECTION AS REQUIRED. NOTE: OUT TO OUT OF FOOTING IS A CRITICAL DIMENSION. SEE PLAN VIEW. INLET OUTLET TYPE STRUCTURE PIPE ARCH PLATE THICKNESS 0.150 SIZE 33 REINFORCING AS SHOWN SKEW 90 116 SPAN = 9'7 RIB SPACING o Z N 2 STANDARD REINFORCED CONCRETE HEADWALL (BY OTHERS) REINFORCED HEADWALL OX" x 19" x 5" HOOK —BOLTS 18" ON CENTER FULL PERIPHERY ALUMINUM STRUCTURAL PLATE L1' 0" MIN. SECTION RISE = 6'6 REINFORCING AS SHOWN BEVEL 0 0 RIB TYPE LENGTH @ CL 78'-6" NUMBER OF STRUCTURES FOR APPROVAL PRE-608521-010-ALSPPA-CON-B The design and fib—to, shown on mis drawing is provided PROJECT No.: SEC. No.: DATE: et°the pm;ectownerangi"eeryndc°ntract°thy Contech Engineered Solufons LLC (" Cometh"). Neithe b, tlmwing, nor any part thereof, may be used, reproduced °r H w��IuT�wu° r r ALUMINUM STRUCTURAL PLATE PIPE ARCH 608521 010 12/20/2018 DESIGNED: DRAWN: m°difed In any manner without the prior written consent of %J)"NTE j�.,,�` ` Co"tech. Failuretocomplyisdo"eattheuaeisuw"riyfo, Con.hrol`presslydisclaims anyliabllithe responsibility f°r ENGINEERED SOLUTIONS LLC STRUCTURAL PLATE 9'-7° SPAN X 6'-6" RISE XXX e e JSC/JCC uch use. panties pp pon w If disc,,between the su lied informationu hich www.ContechES.com 8 DAVIS DRIVE — ENTRY DRIVE CHECKED: APPROVED: the drawing is based and as"ai field condfions are eneoomemd s site work these mscrepanoles m"st be reposed 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 CONTECH CONTRACT ZW M XXX 800-338-1122 513-645-7000 513-645-7993 FAX SHEET NO.: progresses, to Conteehimmediatelyform-eai"af°n or the design.Contech 1 1/8/2019 REVS. PER REVIEW SCC DRAWING DURHAM, NC MARK DATE REVISION DESCRIPTION BY or ccopts no rabirty for designs basad on missing, n. or 4 oP 5 „rate mformationsnppfedbyethers. INVERT C.L. 2r-1 QX2' H 15"12;"Af, 16GA 18 HOLES APPR❑X, 18" C.C. IN NEAREST CAP STUB CREST OR VALLEY, APPR❑X, 6" FROM THE EDGE AS SHOWN FOR 19" x 5" FLOW HOOK BOLTS, 3 PLATE CORNERS PAINTED RED^ O STRUCTURE .I a a •I •I •I a .I •I .I a a 5-41%"1 i ___ A I i O i O 1 O .1 O i O i O i O •1 OA .1 OA i O i O < 1150PTHKE PAINT RED 1 ] I I 1 ] ] I I 1 ] INLET END VIEW NOTE PLATE LAPPING 2T^ O <--- 9N PLATE .150 THK <---15PHKE 10 INVERT C.L. IMPORTANT CORNERS PAINTED RED ASSEMBLY INSTRUCTIONS WILL BE SHIPPED WITH THE STRUCTURE. THEY ARE LOCATED IN THE BRIGHTLY COLORED BOLT KEG. Ll 2' BOTTOM CENTERLINE LENGTH = 78'-0" GENERAL NOTES: 1. Confirmation of cover — This structure is within the minimum and maximum �� OVERALL LENGTH = 78-1 1/2 allowable height of cover, for the designated loading,as follows: Loading; HS -20 Minimum (FT) 5 Maximum or , cover , cover (FT) 11 DEVELOPED PLAN --- OUTSIDE VIEW z. For proper bolt size usage, refer to fallowing: Plate 2 loo 3 lo 4 loo only plate plate plate 0.100" – 0.125" thk. plate 1-1/4" 1-1/4" 1-114"* 0.150" – 0.200" thk. plate 1-1/4" 1-1`2" 2 0.225" – 0.250" thk. plate 1-1/2" 2 N/A With Reinforcing Rib (if read) 0.100" – 0.175" thk. plate 1-1 4" 1-112" 2" 2" 0.200" – 0.250" thk. plate 1-1/2" 2 2" 2" -Occurs with full inverts only which have 0.100" thick plates. 3. Nuts may be located on structure's interior or exterior to allow conventional access during assembly and torquing. Only one side of nut has a curved TCL= 78' 0" surface and it should be in direct contact with plate valley. 4. All plate laps and reinforcing ribs must be properly mated in a tangent fashion using proper alignment techniques and held in alignment by fasteners (finger tightened only). Before backfilling commences, all fasteners must be torqued for adequate component contact. Good component fit is better than high torque. 5. Fastener torque requirements: 0.100" thick plate at 90-115 foot—pounds. For all thicker plates and reinforcing ribs, torque at 115-135 foot—pounds. Torque levels are for installation, not residual, in—service requirements. Since torquing may loosen previously tightened fasteners, multiple passes may be — — — — — — necessary. When seam sealant tape is used, fasteners should be torqued again after 24 hours. 6. All aluminum structural plate material is manufactured in accordance with 1 6p AASHTO M219, ASTM B746 and ASTM 8864 specifications. 7. See ASSEMBLY INSTRUCTIONS shipped with material in fastener container. Also refer to specific product catalog for additional product information. PLAN VIEW THE ASSEMBLY BOLTS AND NUTS ARE SPECIALLY DESIGNED WITH ROUNDED OR SPHERICAL THROATS FOR FITTING EITHER THE CREST OR VALLEY OF THE CORRUGATIONS, PROVIDING MAXIMUM BEARING CONTACT AREA WITH THE PLATES WITHOUT THE USE OF WASHERS. NOTE THAT THE BOLTS AND NUTS SHOULD BE INSTALLED SUCH THAT THE ROUNDED PORTION IS IN CONTACT WITH THE PLATES. INLET OUTLET TYPE STRUCTURE PIPE ARCH PLATE THICKNESS 0.150 SIZE 33 REINFORCING AS SHOWN SKEW 90 116 SPAN 9'7 RIB SPACING RISE 6'6 REINFORCING AS SHOWN RIB TYPE BEVEL 0 0 LENGTH (P CL 78'-0" NUMBER of STRUCTURES 1 FOR APPROVAL PRE-608521-010-ALSPPA-CON-B The design and information shown on this cawing is p.0d.d PROJECT No, SEC. No.: DATE: ass a pwner,en eerand.Neithtorn Prot g y to theEngineered Contech Engineeretl Solutions LLC ('Contech"). Neither this drawing, nor any part thereof, may m used, reproduced or NTECHA���%u_TCAu° >r r ALUMINUM STRUCTURAL PLATE PIPE ARCH 608521 010 12/20/2018 modieedmanymannerwitnouuhe p,i,,wrixenoon,,nt°f �,, j��/�\` `WOiI DESIGNED: DRAWN: Centecn e,aressly etoocalaimeany done at the users inimn riska Contech. piluretocolainns tloneattyorms'snsibil for ENGINEERED SOWTIONS LLC STRUCTURAL PLATE I n I n 9'-7 PAN X 6 —6 RISE XXX JSC/SCC such use. If discrepancies between the supplietl information upon which www.ContechES.com 8 DAVIS DRIVE — ENTRY DRIVE CHECKED: APPROVED: the drawing I, naeed and a°mai geld oondiuons are enonunmmd as site wade these discrepancies must be reported 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 CONTECH CONTRACT ZWM XXX progresses, di to comeon immediatery for re-evemeuon or the design. Cmdech ontpt, 1 1/8/2019 REVS. PER REVIEW SCC 800-338-1122 513-645-7000 513-645-7993 FAX DRAWING DURHAM, NC SHEET NO.: oc no a for designs naeed on mieamg, incomplete or MARK I DATE REVISION DESCRIPTION BY 5 of 5 Ineccummnmfb,nmtu ,upphedbyothers. NOTES: o. RAILROAD BALLAST OR SURGE STONE SHALL BE USED. PAD TO BE 501 X 20'W X 6" D AT A MINIMUM. b. TURNING RADIUS SUFFICIENT TO ACCOMMODATE LARGE TRUCKS IS TO BE PROVIDED. c, ENTRANCE(S) SHOULD BE LOCATED TO PROVIDE FOR MAXIMUM UTILITY BY ALL CONSTRUCTION VEHICLES. d. MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR DIRECT FLOW OF MUD ONTO STREETS. PERIODIC TOPDRESSING WITH STONE SILL BE NECESSARY, KEEP SOME HAND`(. e. ANY MATERIAL WHICH STILL MAKES IT ONTO THE ROAD MUST BE CLEANED UP IMMEDIATELY. RAILROAD B:-- - --_ -- __-- NOTES: APPLICABLE AT ALL POINTS OF INGRESS & EGRESS UNTIL SITE IS STABILIZED, FREQUENT CHECKS OF THE DEVICE AND TIMELY MAINTENANCE MUST BE PROVIDED. NT.nr o,LIA`•'��*� EROSION CONTROL DETAILt`I's� . tip; ` iz' DURHAM COUNTY, NC ENGINEERING DEPARTMENT Y[� RE► SECTION EROSION CONTROL DETATI DURHAM COUNTY, NC ENGINEERING DEPARTMENT REV: I RIPRAP TO EXTENE TOP B da SILT FENCE TO E INSTALLED OVE TOP OF FE SILT FENCE CONSTRUCTION ENTRANCE 011WGRATE I' REBAR FOR REMOVAL FROM INLET FILTER BAG DEFLECTOR DUMP LOOPS I CATCH BASIN ----__-I vIhLET INSTALLATION NOT TO SCALE DATE ID 02109 CE - I NOT TO SCALE CATCH BASIN INLET PROTECTION DATE m 02:09 b1 2 La COOOOO O D SECTION B—B OUTLET Do La W DEPTH LINING NO. (IN.) (FT.) (FT.) (IN.) CLASSIFICATION CHANNEL BOTTOM HEADWALL—NO 1 24 20.0 18.0 36 CLASS 1 FES -16A 15 10.0 4.0 24 CLASS 1 STONE CLASSIFICATIONS OF CLASS B REQUIRE A SUBLAYER OF FILTER FABRIC OR FS -2 FILTER STONE WITH A BEDDING THICKNESS OF 6". MAINTENANCE IN GENERAL, ONCE RIPRAP INSTALLATION HAS BEEN PROPERLY DESIGNED AND INSTALLED IT REQUIRES VERY LITTLE MAINTENANCE. RIPRAP SHOULD BE INSPECTED PERIODICALLY FOR SCOUR OR DISLODGE STONES. CONTROL OF WEED AND BRUSH GROWTH MAY BE NEEDED IN SOME LOCATIONS. RIPRAP OUTLET PROTECTION NTS SEAL 1 A ISSUED FOR PERMIT 2019.04.05 REV.NO. DESCRIPTIONS DATE REVISIONS -11;1 !, Y^ti� aa• STEEL POST IIOYEH HIRE FAME ,IARNM SIGN IIII IIII IIII■■�■r-��-_ 1■■t■11111 ... � .1FA' II I I iii �.+i i�w'�I■ I �■�iiiii► � i'.II ORANGE, UV RESISTANT HLl1 - TENSILE SFABRIC ( PCLY eARRICA-0E FABRIC (TYPICAL) do aRA71f.'E. UV RESISTANT HCH - TENSES STIA7CTH ADE FABi1C 4TYPICALJISI POLY A TrACH VANS SECURE'Lr TO FENCE POSTS AND FAMC. NOTES. STEEL POST IIOYEH HIRE FAME ,IARNM SIGN kl:�--_�pf�l pfl 11 pp Rl 9l p'11111 "1 X1111- ` "1"'"11"411 11nr .1FA' SO4 SHALL SE PLACED A r SO' YAXWN INTERVALS. ___ ■ �L .- -_ _ ORANGE, UV RESISTANT HLl1 - TENSILE SFABRIC ( PCLY eARRICA-0E FABRIC (TYPICAL) do aRA71f.'E. UV RESISTANT HCH - TENSES STIA7CTH ADE FABi1C 4TYPICALJISI POLY A TrACH VANS SECURE'Lr TO FENCE POSTS AND FAMC. m NNE0 n 0 oil ALA CIF ARL HAY ,Wtr NE REOF L AILED LPl ACTUAL Fell) C501O [MS. PLACE A SICK Ai EAGN ETID OF LaEAN THEE PROTECYIp1 ATO 501 ON CENYER rWlrFaF FELL BARML CARRY APPRO1.12" OF FABRIC INTO TRENCK, • Area para Proteecion • ■. ! de los Astieks Its, - Prohlbldo Eetrar j V] WARNING SIGN DETAIL METAL POSTS AT 10'0-C. MAX.. NOT TO SCALE FRONT VIEW b TREE PROTECTION AREA I DO NOT ENTER I WARNING SIGN DETAIL SIDE VIEW NOTES. EROSION CONTROL DETAIL DURHAM COUNTY, NC IrAFAMIG SIGNS TO9E MITRE 9F MAaF- WEA TfIDWROOF AUTET§AL- M- LETTFRS TO BE 3'roGN A71PH84 CLEARLY LEORLE AND SPACES) AS OE FACEOI .1FA' SO4 SHALL SE PLACED A r SO' YAXWN INTERVALS. ___ ■ �L .- -_ _ PLACE A SIGH AT EADi END OF EryEAR TREE PRM TECTON MID 50' MN CENTER TIEREAFTER. GML FOR TREE PROTECTION AREAS LESS THAN POG'A4 PMW TER, PROVOE NO LESS TMIN CIE SIGN PER PROFEC TON AREA. A TrACH VANS SECURE'Lr TO FENCE POSTS AND FAMC. m NNE0 WAMITAW TREE PMTEC TION FENCE TNROUCOWT O.WA FON OF PROJECT, 0 oil ALA CIF ARL HAY ,Wtr NE REOF L AILED LPl ACTUAL Fell) C501O [MS. PLACE A SICK Ai EAGN ETID OF LaEAN THEE PROTECYIp1 ATO 501 ON CENYER rWlrFaF FELL 1=I'"1=_=1�=11=11=11=1E-11=f1=il-y=ll-II u•�i.=i�- I'1=11=11=II- CARRY APPRO1.12" OF FABRIC INTO TRENCK, • Area para Proteecion • ■. ! de los Astieks Its, - Prohlbldo Eetrar j CARRY 6' OF WIRE INTO TRENCH. WARNING SIGN DETAIL EROSION CONTROL DETAIL DUMAM COUNTY, NC 2 ENGINEERING DEPARTMENT NI 1:1.11 nr1kF5 TREE PROTECTION DETAIL SPECIFIC APPLICATION: THIS METHOD OF INLET PROTECTION IS APPLICABLE WHERE HEAVY FLOWS ARE EXPECTED AND WHERE OVERFLOW CAPACITY 15 NECESSARY TO PREVENT EXCESSIVE PONDING AROUND THE STRUCTURE. EROSION CONTROL DETAIL BLOCK AND GRAVEL DURHAM COUNTY, NC ENGINEERING DEPARTMENT STONE INLET PROTECTION BERM AROUND PERIMETER SIGN PLAN 3:1 MAX SIDE SLOPES 12" MIN. GROUND SURFACE 2' MI NON—PERMEABLE GEOMEMBRANE LINER. TUCK 6" INTO BERM AS COMPACTED 8'X8' MIN. SHOWN ON ALL SIDES. EMBANKMENT MATERIAL (TYP.) SECTION CONCRETE WASHOUT AREA INSTALLATION NOTES: 1. SEE PLAN SHEET C3.1 FOR LOCATION OF CONCRETE WASHOUT AREA. (TO BE PLACED A MINIMUM OF 50 FT FROM INLETS, BODIES OF WATER, AND DRAINAGEWAYS.) 2. THE CONCRETE WASHOUT AREA SHALL BE INSTALLED PRIOR TO ANY CONCRETE PLACEMENT ON SITE. 3. SIGNS SHALL BE PLACED AT THE CONSTRUCTION ENTRANCE, AT THE WASHOUT AREA, AND ELSEWHERE AS NECESSARY TO CLEARLY INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA TO OPERATORS OF CONCRETE TRUCKS AND PUMP RIGS. 4. EXCAVATED MATERIAL SHALL BE USED IN PERIMETER BERM CONSTRUCTION. CONCRETE WASHOUT AREA MAINTENANCE NOTES: 1. THE CONCRETE WASHOUT AREA SHALL BE REPAIRED AND ENLARGED OR CLEANED OUT AS NECESSARY TO MAINTAIN CAPACITY FOR WASTED CONCRETE. 2. AT THE END OF CONSTRUCTION, ALL CONCRETE SHALL BE REMOVED AND DISPOSED OF AT APPROVED WASTE SITE. 3. AFTER REMOVAL OF CONCRETE WASHOUT AREA, SEED DISTURBED AREA. 4. INSPECT WEEKLY, DURING AND AFTER ANY STORM EVENT. CONCRETE WASHOUT AREA IF SEAL CARO��ti, , \ ALI/ �_ ::i 028419 _= 4/05/2019 FNGIN101 ; L,� NTS ee encs Pout 6 OG MAX 'I Wire Fence Filter Fabric Hardware Cloth On Ground 511-T F�yCE Filter of 1" Diameter 1 1 i lr' FLOW OF WATER Washed Stone tt 1 I 12 CAUCE i'XA' OR 2'X -l' WELDED WIRE HED. PO5r5 PREFORMED CHANNELS ON tM� � Bury Wire Fence and Hordwore Cloth IIII 3 11+ ULTRAVIpLET RESISTANT (BLACK) MIRIFI I� SECTION FABRIC OR ZW/ METAL LIP -VALENT SECURED TO WIRE S Oft WIRE AT 8 OFro,,32,(0❑W"b0 obp�❑0� ❑ �O a ❑ � C)- CEATER. 6% TO INCREASE STORAGE CAPACITY AND ob PROLONG THE LIFE OF THE SILT FENCE, R d❑ob IS GENERALLY ADVISABLE TO DIG A p 2>op SEDIMENT PIT IN FRONT OF THE SILT pOob FENCE WHENEVER POSSIBLE. MAX. SEDIMENT STORAGE UPAL REMOVE �Sgod ❑b SEDIMENT WHEN THIS LEVEL IS REACHED OR do .60 ob AS DIRECTED 260 $b0 ob EROSION CONTROL DETAIL 7a DURHAM COUNTY, NC ENGINEERING DEPARTMENT DATE 1[l fl:'[19 TP -1 REVt NOT TO SCALE v 4e�NFKRW&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com EROSION CONTROL DETAIL DURHAM COUNTY, NC MCE PROJ. # M- �*irY• .1FA' DESIGNED ___ ■ �L .- -_ _ AlwPANN GML PROJ. MGR. SHEET DRAINAGE (ONLY) m NNE0 _ - _ _m - ------ - - - 0 oil 0 0 0 0 1=I'"1=_=1�=11=11=11=1E-11=f1=il-y=ll-II u•�i.=i�- I'1=11=11=II- CARRY APPRO1.12" OF FABRIC INTO TRENCK, • ■. - SPECIFIC APPLICATION: THIS METHOD OF INLET PROTECTION IS APPLICABLE WHERE HEAVY FLOWS ARE EXPECTED AND WHERE OVERFLOW CAPACITY 15 NECESSARY TO PREVENT EXCESSIVE PONDING AROUND THE STRUCTURE. EROSION CONTROL DETAIL BLOCK AND GRAVEL DURHAM COUNTY, NC ENGINEERING DEPARTMENT STONE INLET PROTECTION BERM AROUND PERIMETER SIGN PLAN 3:1 MAX SIDE SLOPES 12" MIN. GROUND SURFACE 2' MI NON—PERMEABLE GEOMEMBRANE LINER. TUCK 6" INTO BERM AS COMPACTED 8'X8' MIN. SHOWN ON ALL SIDES. EMBANKMENT MATERIAL (TYP.) SECTION CONCRETE WASHOUT AREA INSTALLATION NOTES: 1. SEE PLAN SHEET C3.1 FOR LOCATION OF CONCRETE WASHOUT AREA. (TO BE PLACED A MINIMUM OF 50 FT FROM INLETS, BODIES OF WATER, AND DRAINAGEWAYS.) 2. THE CONCRETE WASHOUT AREA SHALL BE INSTALLED PRIOR TO ANY CONCRETE PLACEMENT ON SITE. 3. SIGNS SHALL BE PLACED AT THE CONSTRUCTION ENTRANCE, AT THE WASHOUT AREA, AND ELSEWHERE AS NECESSARY TO CLEARLY INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA TO OPERATORS OF CONCRETE TRUCKS AND PUMP RIGS. 4. EXCAVATED MATERIAL SHALL BE USED IN PERIMETER BERM CONSTRUCTION. CONCRETE WASHOUT AREA MAINTENANCE NOTES: 1. THE CONCRETE WASHOUT AREA SHALL BE REPAIRED AND ENLARGED OR CLEANED OUT AS NECESSARY TO MAINTAIN CAPACITY FOR WASTED CONCRETE. 2. AT THE END OF CONSTRUCTION, ALL CONCRETE SHALL BE REMOVED AND DISPOSED OF AT APPROVED WASTE SITE. 3. AFTER REMOVAL OF CONCRETE WASHOUT AREA, SEED DISTURBED AREA. 4. INSPECT WEEKLY, DURING AND AFTER ANY STORM EVENT. CONCRETE WASHOUT AREA IF SEAL CARO��ti, , \ ALI/ �_ ::i 028419 _= 4/05/2019 FNGIN101 ; L,� NTS ee encs Pout 6 OG MAX 'I Wire Fence Filter Fabric Hardware Cloth On Ground 511-T F�yCE Filter of 1" Diameter 1 1 i lr' FLOW OF WATER Washed Stone tt 1 I 12 CAUCE i'XA' OR 2'X -l' WELDED WIRE HED. PO5r5 PREFORMED CHANNELS ON tM� � Bury Wire Fence and Hordwore Cloth IIII 3 11+ ULTRAVIpLET RESISTANT (BLACK) MIRIFI I� SECTION FABRIC OR ZW/ METAL LIP -VALENT SECURED TO WIRE S Oft WIRE AT 8 OFro,,32,(0❑W"b0 obp�❑0� ❑ �O a ❑ � C)- CEATER. 6% TO INCREASE STORAGE CAPACITY AND ob PROLONG THE LIFE OF THE SILT FENCE, R d❑ob IS GENERALLY ADVISABLE TO DIG A p 2>op SEDIMENT PIT IN FRONT OF THE SILT pOob FENCE WHENEVER POSSIBLE. MAX. SEDIMENT STORAGE UPAL REMOVE �Sgod ❑b SEDIMENT WHEN THIS LEVEL IS REACHED OR do .60 ob AS DIRECTED 260 $b0 ob EROSION CONTROL DETAIL 7a DURHAM COUNTY, NC ENGINEERING DEPARTMENT DATE 1[l fl:'[19 TP -1 REVt NOT TO SCALE v 4e�NFKRW&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com TEMPORARY SILT FENCE GENERAL NOTES: 1, RIPRAP SIZE TO BE DESIGNED BY ENGINEER, 2. CHECK DAMS MAY BE USED IN SLOPING DITCHES OR CHANNELS TO SLOW VELOCITY OR TO CREATE SEDIMENT TRAPS. 3. ENSURE THAT MAXIMUM SPACING BETWEEN DAMS PLACES THE TOE OF THE UPSTREAM DAM AT THE SAME ELEVATION AS THE DOWNSTREAM DAM (SEE DIAGRAM BELOW). CLASS B RP + q MAXIMUM SPACING B tiI-rlrr+rlrrrlr�llr r� l�IN� r_Ilp�lfl A AND B ARE AT EQUAL ELEVATIONS 11-81 u"'•I O2.•i1A I SF -1 X011 V MAX AT CMffM CROSS SECTION ""y r EROSION CONTROL DETAIL. DATE 10 v e2 Dt 1 DURHAM COUNTY, NC ENGINEERING DEPARTMENT REV POLYETHYLENE MEMBRANE ON FACE 20 MIL THICK T_ LIMITS OF DISTURBANCE (SEE NOTE 1) - T Q Lei 4 FLOW a x SANDBAGS, CLASS 1 RIP RAP OR OTHER ICON -ERODIBLE MATERIAL SYNTHETIC FILTER FABRIC— PLAN i NOT TO SCALE TEMPORARY ROCK CHECK DAM HATE ID 0209 CD - k S-0' D LEVEL WITH TOP OF BANK OR AS NECESSARY CLASS 2 RIP RAP, NJ BARRIER I OR OTHER APPROVED MATERIAL C (IF USING RIP -RAP DOWNSTREAM, 1 SLOPE NO GREATER THAN 2.0: 1) FPIPELINE SEE PROFILE FOR ELEVATION NOTES: 1. CONTRACTOR SHALL INSTALL COFFER DAMS WITH ENOUGH SEPARATION FROM THE PROJECT CONSTRUCTION LIMITS OF DISTURBANCE TO PLACE PUMP INTAKE AND DISCHARGE HOSES, DISSIPATORS AND SEDIMENT FILTER STRUCTURES. 2. TEMPORARY PRE -FABRICATED COFFER DAMS SUCH AS PORT -A -DAM AND OTHERS MAY BE USED IN SUBSTITUTION TO THE SANDBAG/RIP-RAP DAM WITH PRIOR APPROVAL BY THE OWNER AND ENGINEER. COFFER DAM DETAIL NTS Slit F r Tap of Silt Fen Be at Least V the Tap of the Stone Steel Fence Post Set Max. 2• Apart EROSION CONTROL DETAIL DI,rRRAM COU -TY, NC ENGENEERING DEPARTMENT Bury Wire Ferrce, Filter Fabric find Hardware Cloth in Trench SILT FENCE OUTLET III 02109 SF -2 o. MACHINE COMPACTION OF ALL FILL IS REQUIRED. DIVERSIONS SUFFICIENT TO DIRECT ALL SEDIMENT- LADEN STORMWATER INTO A SEDIMENT CONTROL DEVICE MUST BE INSTALLED PRIOR TO CLEARING AND GRUBBING OF THE AREA (OR IN CONJUNCTION WITH THIS OPERATION IF SEDIMENT CONTROLS AND DIVERSIONS ARE iNSTAULD 15 EACH CRITICAL POINT IS REACHED). b. DIVERSIONS SHOULD BE LOCATED TO MINIMIZE DAMAGES BY CONSTRUCTION OPERATIONS. c. DIVERSIONS SHOULD BE SEEDED AND MULCHED IF THEY ARE TO REMAIN IN PLACED OVER 30 DAYS. d. CHECK DEVICE AFTER EACH RAIN, BUT ONCE A WEEK REGARDLESS. REPAIR AS NECESSARY. 12' MIN SLOPE 2:1 4� MAX m NATURAL GROUND OR FILL OR CUT - SLOPES COMPACTED FILL BERM 16' MIN �0'0 � ' I I DITCH 18' MIN FLOW 12' MIN I I BERM/DITCH NOTES: POSITIVE GRADE MUST BE PROVIDED TO ASSURE DRAINAGE. IF SLOPE EXCEEDS 2%. SEED AND MULCH DIVERSION. TTS/ NOT TO EXCEED 5X . MAX. DRANAGE AREA = 5 ACRES WITHOUT SUPPORTING CALCS.. PES MUST EMPTY INTO AN /DITCH IS MOST COMMONLY USED. NOT TO SW A.A�4A• EROSION CONTROL DETAIL DURHAM COUNTY, NC MCE PROJ. # M- �*irY• .1FA' DESIGNED ___ ■ �L .- -_ _ TRENCH. COVER W/ SOIL k TAMP BACKFILL. GML PROJ. MGR. SHEET DRAINAGE (ONLY) D3.0 3•0 _ - _ _m - ------ - - - - NATURAL CRADE CARRY APPRO1.12" OF FABRIC INTO TRENCK, CARRY 6' OF WIRE INTO TRENCH. METAL POSTS AT 10'0-C. MAX.. NOT TO SCALE TEMPORARY SILT FENCE GENERAL NOTES: 1, RIPRAP SIZE TO BE DESIGNED BY ENGINEER, 2. CHECK DAMS MAY BE USED IN SLOPING DITCHES OR CHANNELS TO SLOW VELOCITY OR TO CREATE SEDIMENT TRAPS. 3. ENSURE THAT MAXIMUM SPACING BETWEEN DAMS PLACES THE TOE OF THE UPSTREAM DAM AT THE SAME ELEVATION AS THE DOWNSTREAM DAM (SEE DIAGRAM BELOW). CLASS B RP + q MAXIMUM SPACING B tiI-rlrr+rlrrrlr�llr r� l�IN� r_Ilp�lfl A AND B ARE AT EQUAL ELEVATIONS 11-81 u"'•I O2.•i1A I SF -1 X011 V MAX AT CMffM CROSS SECTION ""y r EROSION CONTROL DETAIL. DATE 10 v e2 Dt 1 DURHAM COUNTY, NC ENGINEERING DEPARTMENT REV POLYETHYLENE MEMBRANE ON FACE 20 MIL THICK T_ LIMITS OF DISTURBANCE (SEE NOTE 1) - T Q Lei 4 FLOW a x SANDBAGS, CLASS 1 RIP RAP OR OTHER ICON -ERODIBLE MATERIAL SYNTHETIC FILTER FABRIC— PLAN i NOT TO SCALE TEMPORARY ROCK CHECK DAM HATE ID 0209 CD - k S-0' D LEVEL WITH TOP OF BANK OR AS NECESSARY CLASS 2 RIP RAP, NJ BARRIER I OR OTHER APPROVED MATERIAL C (IF USING RIP -RAP DOWNSTREAM, 1 SLOPE NO GREATER THAN 2.0: 1) FPIPELINE SEE PROFILE FOR ELEVATION NOTES: 1. CONTRACTOR SHALL INSTALL COFFER DAMS WITH ENOUGH SEPARATION FROM THE PROJECT CONSTRUCTION LIMITS OF DISTURBANCE TO PLACE PUMP INTAKE AND DISCHARGE HOSES, DISSIPATORS AND SEDIMENT FILTER STRUCTURES. 2. TEMPORARY PRE -FABRICATED COFFER DAMS SUCH AS PORT -A -DAM AND OTHERS MAY BE USED IN SUBSTITUTION TO THE SANDBAG/RIP-RAP DAM WITH PRIOR APPROVAL BY THE OWNER AND ENGINEER. COFFER DAM DETAIL NTS Slit F r Tap of Silt Fen Be at Least V the Tap of the Stone Steel Fence Post Set Max. 2• Apart EROSION CONTROL DETAIL DI,rRRAM COU -TY, NC ENGENEERING DEPARTMENT Bury Wire Ferrce, Filter Fabric find Hardware Cloth in Trench SILT FENCE OUTLET III 02109 SF -2 o. MACHINE COMPACTION OF ALL FILL IS REQUIRED. DIVERSIONS SUFFICIENT TO DIRECT ALL SEDIMENT- LADEN STORMWATER INTO A SEDIMENT CONTROL DEVICE MUST BE INSTALLED PRIOR TO CLEARING AND GRUBBING OF THE AREA (OR IN CONJUNCTION WITH THIS OPERATION IF SEDIMENT CONTROLS AND DIVERSIONS ARE iNSTAULD 15 EACH CRITICAL POINT IS REACHED). b. DIVERSIONS SHOULD BE LOCATED TO MINIMIZE DAMAGES BY CONSTRUCTION OPERATIONS. c. DIVERSIONS SHOULD BE SEEDED AND MULCHED IF THEY ARE TO REMAIN IN PLACED OVER 30 DAYS. d. CHECK DEVICE AFTER EACH RAIN, BUT ONCE A WEEK REGARDLESS. REPAIR AS NECESSARY. 12' MIN SLOPE 2:1 4� MAX m NATURAL GROUND OR FILL OR CUT - SLOPES COMPACTED FILL BERM 16' MIN �0'0 � ' I I DITCH 18' MIN FLOW 12' MIN I I BERM/DITCH NOTES: POSITIVE GRADE MUST BE PROVIDED TO ASSURE DRAINAGE. IF SLOPE EXCEEDS 2%. SEED AND MULCH DIVERSION. TTS/ NOT TO EXCEED 5X . MAX. DRANAGE AREA = 5 ACRES WITHOUT SUPPORTING CALCS.. PES MUST EMPTY INTO AN /DITCH IS MOST COMMONLY USED. NOT TO SW A.A�4A• EROSION CONTROL DETAIL DURHAM COUNTY, NC MCE PROJ. # ENGINEERING DEPARTMENT �*irY• .1FA' ' 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA 0— EROSION CONTROL DETAILS DIVERSION DITCH DETAIL DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 DRAWN DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML D3.0 3•0 N/A u2 09 I DD - 1 SCALE M&C FILE NUMBER D3.0 HORIZONTAL: DRAWING NUMBER N/A VERTICAL: D3.0 3•0 N/A STATUS: REVISION NOT FOR CONSTRUCTION A � ISSUED FOR REVIEW ONLY RECOMMENDATIONS FOR LATE WINTER AND EARLY SPRING SEEDING MIXTURE SPECIES RATE Ib acre) RYE (GRAIN) 120 ANNUAL LESPEDEZA (KOBE IN 50 PIEDMONT & COASTAL PLAIN, KOREAN IN MOUNTAINS OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYOND JUNE SEEDING DATES: MOUNTAINS (ABOVE 2,500'): FEB. 15 - MAY 15 (BELOW 2,500'): FEB. 1 - MAY 1 PIEDMONT: JAN. 1 - MAY 1 COASTAL PLAIN: DEC. 1 - APR. 15 SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 Ib/acre GROUND AGRICULTURAL LIMESTONE AND 750 Ib/acre 10-10-10 FERTILIZER MULCH: APPLY 4.000 Ib/acre STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. RECOMMENDATIONS FOR SUMMER SEEDING MIXTURE SPECIES RATE Ib acre) GERMAN MILLET 40 IN THE PIEDMONT AND MOUNTAINS, A SMALL -STEMMED SUDANGRASS MAY BE SUBSTITUTED AT A RATE OF 50 Ib/acre. SEEDING DATES: MOUNTAINS MAY 15 - AUG. 15 PIEDMONT: MAY 1 - AUG. 15 COASTAL PLAIN: APR. 15 - AUG. 15 SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 Ib/acre GROUND AGRICULTURAL LIMESTONE AND 750 Ib/acre 10-10-10 FERTILIZER MULCH: APPLY 4.000 Ib/acre STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. RECOMMENDATIONS FOR FALL SEEDING MIXTURE SPECIES RATE (Ib acre RYE (GRAIN) 120 SEEDING DATES: MOUNTAINS: AUG. 15 - DEC. 15 COASTAL PLAIN AND PIEDMONT: AUG. 15 - DEC. 30 SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 Ib/acre GROUND AGRICULTURAL LIMESTONE AND 750 Ib/acre 10-10-10 FERTILIZER MULCH: APPLY 4.000 Ib/acre STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOPDRESS WITH 50 Ib/acre OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 Ib/acre KOBE (PIEDMONT AND COASTAL PLAIN) OR KOREAN (MOUNTAINS) LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. TEMPORARY SEEDING SCHEDULE 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. 2. RIP THE ENTIRE AREA TO 6 INCHES DEPTH. 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 4. APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL (SEE BELOW*). 5. CONTINUE TILLAGE UNTIL A WELL - PULVERIZED, FIRM, REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 INCHES DEEP. 6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING EQUIPMENT OR CULTIPACK AFTER SEEDING. 7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. IF STAND SHOULD BE OVER 60% DAMAGED REESTABLISH FOLLOWING ORIGINAL LIME, FERTILIZER AND SEEDING RATES. 9. CONSULT CONSERVATION INSPECTOR ON MAINTENANCE TREATMENT AND FERTILIZATION AFTER PERMANENT COVER IS ESTABLISHED. * APPLY: AGRICULTURAL LIMESTONE - 2 TONS/ACRE OR 3 TONS/ACRE IN CLAY SOILSFERTILIZER - 1000 LBS/ACRE (10-10-10) SUPERPHOSPHATE - 500 LBS/ACRE (20%) MULCH - 2 TONS/ACRE (SMALL GRAIN STRAW)ANCHOR - ASPHALT EMULSION AT 450 GAL./ACRE SEEDBED PREPARATION RECOMMENDATIONS FOR LATE WINTER AND EARLY SPRING SEEDING MIXTURE SPECIES RATE (Ib acre] TALL FESCUE 80 KOBE LESPEDEZA 40 NURSE PLANTS: BETWEEN MAY 1 AND AUG. 15, ADD 10 Ib/acre GERMAN MILLET OR 15 Ib/acre SUDANGRASS. PRIOR TO MAY 1 OR AFTER AUG. 15, ADD 40 Ib/ac RYE (GRAIN) SEEDING DATES: BEST POSSIBLE FALL AUG. 15 - SEPT. 15 AUG. 20 - OCT. 25 LATE WINTER: FEB. 15 - MAR. 21 FEB. 1 - APR. 15. FALL IS BEST FOR TALL FESCUE AND LATER WINTER FOR LESPEDEZAS. OVERSEEDING OF DOBE LESPEDEZA OVER FALL -SEEDED TALL FESCUE IS VERY EFFECTIVE. SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 Ib/acre GROUND AGRICULTURAL LIMESTONE AND 750 Ib/acre 10-10-10 FERTILIZER MULCH: APPLY 4.000 Ib/acre STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: REFERTILIZE IN THE SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE. MAY BE MOWED ONCE OR TWICE A YEAR, BUT MOWING IS NOT NECESSARY. RESEED, FERTILIZE AND MULCH DAMAGED AREAS IMMEDIATELY. RECOMMENDATIONS FOR GRASS -LINED CHANNELS SEEDING MIXTURE SPECIES RATE (Ib/acre] TALL FESCUE 200 NURSE PLANTS: BETWEEN MAY 1 AND AUG. 15, ADD 10 Ib/acre SUDANGRASS OR 15 Ib/acre GERMAN MILLET. PRIOR TO MAY 1 OR AFTER AUG. 15, ADD 40 Ib/ac RYE (GRAIN) SEEDING DATES: BEST: AUG. 25 - OCT. POSSIBLE: FEB. - APR. 15 AVOID SEEDING FROM NOV. TO JAN. IF SEEDING MUST BE DONE AT THIS TIME, ADD 40 Ib/acre RYE GRAIN AND USE A CHANNEL LINING THAT OFFERS MAXIMUM PROTECTION SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 4,000 Ib/acre GROUND AGRICULTURAL LIMESTONE AND 1,000 Ib/acre 10-10-10 FERTILIZER MULCH: USE ROLLED EROSION CONTROL PRODUCT TO COVER THE BOTTOM OF THE CHANNELS AND DITCHES, AND STAPLE SECURELY. THE LINING SHOULD EXTEND ABOVE THE HIGHEST CALCULATED DEPTH OF FLOW. ON CHANNEL SIDE SLOPES ABOVE THIS HEIGHT, AND IN DRAINAGES NOT REQUIRING TEMPORARY LININGS, APPLY 4,000 Ib/acre GRAIN STRAW, AND ANCHOR STRAW BY STAPLING NETTING OVER THE TOP. MULCH AND ANCHORING MATERIALS MUST NOT BE ALLOWED TO WASH DOWN SLOPES WHERE THEY CAN CLOG DRAINAGE DEVICES. MAINTENANCE: INSPECT AND REPAIR MULCH FREQUENTLY. REFERTILIZE IN LATE WINTER OF THE FOLLOWING YEAR; USE SOIL TESTS OR APPLY 150 Ib/acre 10-10-10. MOW REGULARLY TO A HEIGHT OF 2-4 INCHES. NOTE: SEE NCDENR'S EROSION AND SEDIMENT CONTROL PLANNING DESIGN MANUAL SECTION 6.11 FOR ADDITIONAL PERMANENT SEEDING OPTIONS. PERMANENT SEEDING SCHEDULE SEAL 1 A ISSUED FOR PERMIT 2019.04.05 REV.NO. DESCRIPTIONS DATE REVISIONS SEAL CARO��ti, , %PEES Nq� 9 %- L 028419 _= 4/05/2019 PLAN VIEW CLEAN WA TER COFFER DAM (SEE DETAIL 5 THIS SHEET) PUMPS SHOULD DISCHARGE ONTO A STABLE VELOCITY DISSIPATOR MADE OF RIP RAP OR SANDBAGS FLOW SEDIMENT CONTAINMENT COFFER DAM (SEE DETAIL 5 THIS SHEET) CONTRACTOR TO 'VIDE DEWATERING PUMP IN TRENCH. STREAM DI VERSION PUMPS INTAKE HOSE W/ i� INLET SCREEN WORK AREA WIDTH NOT TO EXCEED CONSTRUCTION LIMITS SHOWN ON PLANS SUMP -HOLE OR POOL PUMP -AROUND PRACTICE. - TEMPORARY MEASURE FOR DEWATERING STREAM CROSSING SITES. DESCRIPTION.- THE ESCRIPTION.THE WORK SHOULD CONSIST OF INSTALLING A TEMPORARY PUMP AROUND AND SUPPORTING MEASURES TO DIVERT FLOW AROUND CONSTRUCTION. PUMPS SHALL BE SIZED IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS. IMPLEMENTATION SEQUENCE.' SEDIMENT CONTROL MEASURES, PUMP -AROUND PRACTICES, AND ASSOCIATED CONSTRUCTION SHOULD BE COMPLETED IN THE FOLLOWING SEQUENCE (REFER TO DETAIL). 1. COFFER DAMS SHOULD BE SI TUA TED AT THE ENDS OF THE WORK AREA AS SHOWN ON THE PLANS, AND WATER ON THE UPSIDE OF THE DAM AREA SHOULD BE PUMPED AROUND THE WORK AREA. 2. THE PUMP SHOULD DISCHARGE ONTO A STABLE VELOCITY DISSIPATER MADE OF RIP -RAP OR SANDBAGS. 3. WATER FROM THE WORK AREA SHOULD BE PUMPED TO A SEDIMENT FILTERING MEASURE SUCH AS A TEMPORARY WOOD CHIP DEWATERING BASIN, SILT BAG OR OTHER APPROVED SEDIMENT FILTERING MEASURE. 4. AFTER THE SANITARY SEWER IS INSTALLED AND THE SLOPES HAVE BEEN STABILIZED, THE PUMP INTAKE HOSES, DISSIPATOR PADS AND FILTER MEASURES SHOULD BE REMOVED AND THEN THE COFFER DAMS SHOULD BE REMOVED. 5. A PUMP AROUND MUST BE INSTALLED ON ANY TRIBUTARY OR STORM DRAIN OUTFALL WHICH CONTRIBUTES BASEFLOW TO THE WORK AREA. THIS SHOULD BE ACCOMPLISHED BY LOCATING A COFFER DAM AT THE DOWNSTREAM END OF THE TRIBUTARY OR STORM DRAIN OUTFALL AND PUMPING THE STREAM FLOW AROUND THE WORK AREA. THIS WATER SHOULD DISCHARGE ONTO THE SAME VELOCITY DISSIPATER USED FOR THE MAIN STEM PUMP AROUND. TEMPORARY PUMP AROUND DETAIL NTS INVERT CLASS\�AO1RIP \EE IT ELOW C 1 RIP RAP \ A ALL //��/////lllllllllllll �__ HED ONE. 1' / / I IR I \ \\RA \\\ K X 3' IGH MIN. PERSPECTIVE VIEW AREAS TO BE DISTURBED SEDIMENT STORAGE PIPE INVERT (CUT, FILL, ETC.) FLOOD STORAGE ZONE RIP RAP HEADWALL r z' NATURAL 5 3' GROUND �0{y1.5 CLASS 1 RIP -RAP NOTE: FILTER FABRIC DIMENSIONS ARE /57 WASHED STONE MINIMUM ACCEPTABLE MAX. SEDIMENT DEPTH(CLEAN OUT POINT) UNLESS OTHERWISE NOTED. SECTION THRU BASIN, FILTER AND CULVERT PIPE NOTE: GRAVEL & RIP RAP FILTER BERM BASIN DETAIL IS DESIGNED TO PROTECT EXISTING PIPE INVERTS THAT DRAIN 10 ACRES OR LESS. ►•,ran���.rai•�y� 1. INSPECT ROCK PIPE INLET PROTECTION AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (j INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE SEDIMENT STORAGE AREA TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN THE DESIGNATED DISPOSAL AREA AND REPLACE THE CONTAMINATED PART OF THE GRAVEL FACING. CHECK THE STRUCTURE FOR DAMAGE. ANY RIPRAP DISPLACED FROM THE STONE HORSESHOE MUST BE REPLACED IMMEDIATELY. AFTER ALL SEDIMENT -PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE THE STRUCTURE AND ALL THE UNSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND PROVIDE PERMANENT GROUND COVER. ARC FILTER INLET PROTECTION NTS v vNFKUW&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com CI GR ADE SEED AS SPECIFIED IN SEEDING SCHEDULE W 2' �I MAX. 3:1 SLOPE GRADE SWALE # LENGTH (FT) SLOPE (%) d (FT) W (FT) TEMPORARY LINER PERMANENT LINER 1 113 5.3 1.15 11 STRAW W/ NET GRASS MIXTURE 2 126 5.6 1.24 11 STRAW W/ NET GRASS MIXTURE 3 88 3.4 1.31 11 STRAW W/ NET GRASS MIXTURE 4 90 3.3 1.25 11 STRAW W/ NET GRASS MIXTURE STRAW WITH NET LINER RECP MUST MEET THE FOLLOWING MINIMUM SPECIFICATIONS: a. STRAW: 100% STRAW (0.5 LBS/YD') b. NETTING: TOP SIDE ONLY, PHOTO DEGRADABLE, APPROX. 1/Z" X 1/Z" MESH (1.64LB/1000 FT Z) c. THREAD: DEGRADABLE PERMANENT GRASSED SWALE NTS PUMP - DISCHARGE HOSE WATER PUMP FILTERED WATER DANDY TM - DEWATERING BAG Flow � l l � INSTALLATION AND MAINTENANCE GUIDELINES INSERT DISCHARGE HOSE FROM PUMP INTO DANDY DEWATERING BAG A MINIMUM OF SIX INCHES (6") AND TIGHTLY SECURE WITH THE ATTACHED STRAP TO PREVENT WATER FROM FLOWING OUT OF THE UNIT WITHOUT BEING FILTERED. IF USING OPTIONAL ABSORBENTS, PLACE ABSORBENT BOOM INTO THE DANDY DEWATERING BAG. CLIP ABSORBENT BOOM TO TETHER PROVIDED INSIDE THE UNIT. MAINTENANCE: REPLACE THE UNIT WHEN 1/2 FULL OF SEDIMENT OR WHEN SEDIMENT HAS REDUCED THE FLOW RATE OF THE PUMP DISCHARGE TO AN IMPRACTICAL RATE. IF USING OPTIONAL OIL ABSORBENTS; REMOVE AND REPLACE ABSORBENT WHEN NEAR SATURATION. TIE DOWN STRAP NOTES: 1. LAY DOWN PLASTIC ON GROUND IN AREA WHERE BAG WILL SIT AND DISHARGE PATH. 2. PLACE BAG ON PALLETS OR GRAVEL TO ENSURE MAXIMUM DRAINAGE AND ALLOW EQUIPMENT TO PICK UP TO HAUL OFF. 3. PROP BAG UP AT SLIGHT ANGLE SO WATER DISCHARGES TOWARD RIVER AND DOES NOT CREATE A POOL WHEN DRAINING. 4. WHEN INSTALLING NEW BAG MOVE LOCATION OVER AS NOT TO KILL GRASS AND PLANTINGS. 5. CONTRACTOR TO RETURN AREA TO EXISTING CONDITIONS AFTER BAGS ARE NO LONGER NEEDED. DANDY DEWATERING BAG DETAIL NTS 6 DAVIS DRIVE ENTRY DRIVE DURHAM COUNTY, NORTH CAROLINA EROSION CONTROL DETAILS DATE: APRIL 5, 2019 MCE PROJ. # 07473-0001 DRAWN DJB DESIGNED DJB CHECKED GML PROJ. MGR. GML SCALE HORIZONTAL: N/A VERTICAL: N/A M&C FILE NUMBER D3.0 DRAWING NUMBER D3.1 STATUS: REVISION NOT FOR CONSTRUCTION A ISSUED FOR REVIEW ONLY `�� NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Donald R. van der Vaart Governor Secretary May 14, 2015 DWR # 15-0378 Durham County ARE -NC Region No. 14, LLC Attn: Oliver Sherrill, Senior Vice President 7020 Kit Creek Rd., Ste. 100 Research Triangle Park, NC 27700-332° Subject: APPROVAL OF 401 WATER QUALITY CERTIFICATION WITH ADDITIONAL CONDITIONS Davis Drive Entrance Road Dear Mr. Sherrill: You have our approval for the impacts listed below for the purpose described in your application dated April 1, 2015 and received by the Division of Water Resources (Division) on April 20, 2015. These impacts are covered by the attached Water Quality General Certification Numbers 3885 and 3886 and the conditions listed below. This certification is associated with the use of Nationwide Permit Numbers 13 and 14 once they are issued to you by the U.S. Army Corps of Engineers. Please note that you should get any other federal, state or local permits before proceeding with your project, including those required by (but not limited to) Sediment and Erosion Control, Non -Discharge, and Water Supply Watershed regulations. This approval requires you to follow the conditions listed in the enclosed certification and the following additional conditions: 1. The foilowing impacts are hereby approved provided that al! of the other specific and general conditions of the Certification are met. No other impacts are approved, including incidental impacts. [15A NCAC 02B .0506(b)(c)] Type of Impact Amount Approved Amount Approved (units) (units) Permanent Temporary Wetland 0.0027 (acres) 0 (acres) Division of Water Resources, Raleigh Regional Office, Water Quality Operations Section http://portal.ncdenr.org/web/wq/aps 1628 Mail Service Center, Raleigh, NC 27699-1628 Phone: (919) 791-4200 Location: 3800 Barrett Drive, Raleigh, NC 27609 Fax: (919) 788-7159 An Equal Opportunity 1 Affirmative Action Employer —Made in part by recycled paper Davis Drive Entrance Road DWR# 15-0378 401APPROVAL Page 2 of 4 Culvert Stream 94 (linear feet) 0 (linear feet) Culvert Stream 50 (linear feet) 0 (linear feet) Stabilization 2. Stormwater Management Plan (SMP) Approved by a Delegated Local Community The SMP approved by Durham County on December 5, 2014 meets the requirements of the 401 Certification Program. The SMP may not be modified without prior written authorization from Durham County. A copy of the approval letter and the modified SMP shall be submitted to the DWR 401 & Buffer Permitting Unit (1617 Mail Service Center, Raleigh, NC 27699-1617) prior to the commencement of the modifications. [15A NCAC 02H .0506(b)(5)] 3. No Waste, Spoil, Solids, or Fill of Any Kind No waste, spoil, solids, or fill of any kind shall occur in wetlands, waters, or riparian areas beyond the footprint of the impacts depicted in the Pre -Construction Notification. All construction activities, including the design, installation, operation, and maintenance of sediment and erosion control Best Management Practices, shall be performed so that no violations of state water quality standards, statutes, or rules occur. [15A NCAC 02H .0501 and .0502] 4. Protective Fencing The outside buffer, wetland or water boundary and along the construction corridor within these boundaries approved under this authorization shall be clearly marked with orange warning fencing (or similar high visibility material) for the areas that have been approved to infringe within the buffer, wetland or water prior to any land disturbing activities to ensure compliance with 15 NCAC 02H .0500. [15A NCAC 02H .0506 (b)(2) and (c)(2) and 15A NCAC 02H .0507 (c)] 5. This approval is for the purpose and design described in your application. The plans and specifications for this project are incorporated by reference as part of the Certification. If you change your project, you must notify the Division and you may be required to submit a new application package with the appropriate fee. If the property is sold, the new owner must be given a copy of this approval letter and General Certification and is responsible for complying with all conditions. [15A NCAC 02B .0507(d)(2)] 6. This approval and its conditions are final and binding unless contested. [G.S. 143-215.5] This Certification can be contested as provided in Articles 3 and 4 of General Statute 150B by filing a written petition for an administrative hearing to the Office of Administrative Hearings (hereby known as OAH). A petition form may be obtained from the OAH at http://www.ncoah.com/ or by calling the OAH Clerk's Office at (919) 431-3000 for information. Davis Drive Entrance Road DWR# 15-0378 401 APPROVAL Page 3 of 4 Within thirty (30) calendar days of receipt of this notice, a petition must be filed with the OAH. A petition is considered filed when the original and one (1) copy along with any applicable OAH filing fee is received in the OAH during normal office hours (Monday through Friday between 8:00am and 5:00pm, excluding official state holidays). The petition may be faxed to the OAH at (919) 431-3100, provided the original and one copy of the petition along with any applicable OAH filing fee is received by the OAH within five (5) business days following the faxed transmission. Mailing address for the OAH: If sending by First Class Mail via the US Postal Service: Office of Administrative Hearings 6714 Mail Service Center Raleigh, NC 27699-6714 If sending via delivery service (e.g. UPS, FedEx): Office of Administrative Hearings 1711 New Hope Church Road Raleigh, NC 27609-6285 One (1) copy of the petition must also be served to DENR: Sam Hayes, General Counsel Department of Environment and Natural Resources 1601 Mail Service Center Raleigh, NC 27699-1601 Please send one (1) copy of the petition to DWR: If sending by First Class Mail via the US Postal Service: Karen Higgins NC DENR-DWR — 401 & Buffer Permitting Unit 1617 Mail Service Center Raleigh, NC 27699-1617 If sending via delivery service (e.g. UPS, FedEx): Karen Higgins NC DEN R-DWR — 401 & Buffer Permitting Dnit 512 N. Salisbury Street Raleigh, NC 27604 This letter completes the review of the Division under section 401 of the Clean Water Act. Please contact Cherri Smith at 919-791-4251 or cherri.smith@ncdenr.gov if you have any questions or concerns. Davis Drive Entrance Road DWR# 15-0378 401APPROVAL i Page 4 of 4 Sincerel�l Danny Smith Supervisor, Water Quality Regional Operations Section Enclosures: GC 3885 and GC 3886 cc: U.S. Army Corps of Engineers; Raleigh Regulatory Field Office; 3331 Heritage Trade Drive, Ste. 105; Wake Forest, NC 27597 Becky Ward; Ward Consulting Engineers; 4805 Green Road, Ste. 100; Raleigh, NC 27616 U.S. ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Action Id. SAW -2015-00891 County: Durham U.S.G.S. Quad: NC -SOUTHEAST DURHAM GENERAL PERMIT (REGIONAL AND NATIONWIDE) VERIFICATION Permittee: ARE -NC Region No. 14, LLC Oliver Sherrill Address: 7020 Kit Creek Road Suite 100 Research Triangle Park, NC, 27709-3329 Telephone Number: 919-313-6645 Size (acres) 42.4 Nearest Town Durham Nearest Waterway UT Burdens Creek River Basin Haw. North Carolina. USGS HUC 3030002 Coordinates Latitude: 35.89901 Longitude: -78.86216 Location description: Proiect site is located at Hamner Institute for Health Services 6 Davis Drive, Durham, North Carolina. Description of projects area and activity: _Expansion of existing institution, impacting 144 linear feet of stream and 116 square feet of wetlands for extension of a culvert for an entrance road. Applicable Law: ® Section 404 (Clean Water Act, 33 USC 1344) ❑ Section 10 (Rivers and Harbors Act, 33 USC 403) Authorization: Nationwide Permit Number: NWP 13 Bank Stabilization; NWP 14 Linear Transportation Projects. SEE ATTA CHED RCP or NWP GENERAL, REGIONAL AND SPECIAL CONDITIONS Your work is authorized by the above referenced permit provided it is accomplished in strict accordance with the attached conditions and your submitted application and attached information dated 04/20/2015. Any violation of the attached conditions or deviation from your submitted plans may subject the permittee to a stop work order, a restoration order, a Class I administrative penalty, and/or appropriate legal action. This verification will remain valid until the expiration date identified below unless the nationwide authorization is modified, suspended or revoked. If, prior to the expiration date identified below, the nationwide permit authorization is reissued and/or modified, this verification will remain valid until the expiration date identified below, provided it complies with all requirements of the modified nationwide permit. If the nationwide permit authorization expires or is suspended, revoked, or is modified, such that the activity would no longer comply with the terms and conditions of the nationwide permit, activities which have commenced (i.e., are under construction) or are under contract to commence in reliance upon the nationwide permit, will remain authorized provided the activity is completed within twelve months of the date of the nationwide permit's expiration, modification or revocation, unless discretionary authority has been exercised on a case-by-case basis to modify, suspend or revoke the authorization. Activities subject to Section 404 (as indicated above) may also require an individual Section 401 Water Quality Certification. You should contact the NC Division of Water Quality (telephone 919-807-6300) to determine Section 401 requirements. This Department of the Army verification does not relieve the permittee of the responsibility to obtain any other required Federal, State or local approvals/permits. If there are any questions regarding this verification, any of the conditions of the Permit, or the Corps of Engineers regulatory program, please contact Eric Alsmever at 919-554-4884 x23 or Eric C Alsmeyer(2usace army mil. Digitally signed by ALSMEYER.ERIC.C.1087624486 r�+t DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, /'� ou=USA, cn=ALSMEYER.ERIC.C.1087624486 Corps Regulatory Official: R' Date: 2015.05.2916:24:13 -04-00- Expiration Date of Verification: 03/18/2017 Date: 05/29/2015 SAW -2015-00891 Determination of Jurisdiction: A. ❑ Based on preliminary information, there appear to be waters of the US including wetlands within the above described project area. This preliminary determination is not an appealable action under the Regulatory Program Administrative Appeal Process ( Reference 33 CFR Part 331). B. ❑ There are Navigable Waters of the United States within the above described project area subject to the permit requirements of Section 10 of the Rivers and Harbors Act and Section 404 of the Clean Water Act. Unless there is a change in the law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. C. ® There are waters of the US and/or wetlands within the above described project area subject to the permit requirements of Section 404 of the Clean Water Act (CWA)(33 USC § 1344). Unless there is a change in the law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. D. ❑ The jurisdictional areas within the above described project area have been identified under a previous action. Please reference jurisdictional determination issued . Action ID: SAW - Basis For Determination: The project impact area contains a relatively permanent waters, with indicators of ordinary high water marks, a stream channel of an unnamed tributary of Burdens Creek, and abutting wetlands. Burdens Creek is a tributary of Northeast Creek and Jordan Lake. Jordan Lake is a Traditional Navigable Water. Remarks: This JD was confirmed by field inspection on 12/10/2014. The attached survey plat, Sheet 1 of 1, "WETLANDS LOCATION SURVEY, ARE -NC REGION No. 14, LLC, 6 DAVIS DRIVE" dated 1-16-15, accurately depicts the jurisdictional waters of the US within the subject project impact area. E. Attention USDA Program Participants This delineation/determination has been conducted to identify the limits of Corps' Clean Water Act jurisdiction for the particular site identified in this request. The delineation/determination may not be valid for the wetland conservation provisions of the Food Security Act of 1985. If you or your tenant are USDA Program participants, or anticipate participation in USDA programs, you should request a certified wetland determination from the local office of the Natural Resources Conservation Service, prior to starting work. F. Appeals Information (This information applies only to approved jurisdictional determinations as indicated in B and C above). This correspondence constitutes an approved jurisdictional determination for the above described site. If you object to this determination, you may request an administrative appeal under Corps regulations at 33 CFR Part 331. Enclosed you will find a Notification of Appeal Process (NAP) fact sheet and request for appeal (RFA) form. If you request to appeal this determination you must submit a completed RFA form to the following address: US Army Corps of Engineers South Atlantic Division Attn: Jason Steele, Review Officer 60 Forsyth Street SW, Room 10M 15 Atlanta, Georgia 30303-8801 Phone: (404) 562-5137 In order for an RFA to be accepted by the Corps, the Corps must determine that it is complete, that it meets the criteria for appeal under 33 CFR part 331.5, and that it has been received by the Division Office within 60 days of the date of the NAP. Should you decide to submit an RFA form, it must be received at the above address by 7/27/2015. "It is not necessary to submit an RFA form to the Division Office if you do not object to the determination in this correspondence." Digitally signed by ALSM EYER.ERIC.C.1087624486 CDN: c=US, o=US. Government, ou=DoD, ou=PKI, ou=USA cn=ALSMEYER.ERIC.C.1087624486 Corps Regulatory Official: Date: 2015.05191624:31 -04'00' Eric Alsmeyer Date of JD: 05/29/2015 Expiration Date of JD: 5/29/2020 SAW -2015-00891 The Wilmington District is committed to providing the highest level of support to the public. To help us ensure we continue to do so, please complete our customer Satisfaction Survey online at http://regulatpH.usacesurvey.com/. Copies furnished: Agent: Ward Consulting EnLyineers, PC Becky Ward Address: 4805 Green Rd. Suite 100 Raleigh, NC, 27616 Consultant: Cory Darnell _ECS Carolinas, LLP 9001 Glenwood Ave Raleigh, NC 27617 Action ID Number: SAW -2015-00891 County: Durham Permittee: ARE -NC Region No. 14, LLC Oliver Sherrill Project Name: ARE -NC Region No. 14, LLC Davis Drive Entrance Road Date Verification Issued: 05/29/2015 Project Manager: Eric Alsmever Upon completion of the activity authorized by this permit and any mitigation required by the permit, sign this certification and return it to the following address: US ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Attn: Eric Alsmeyer US Army Corps of Engineers, Wilmington District Raleigh Regulatory Field Office 3331 Heritage Trade Drive, Suite 105 Wake Forest, NC 27587 Please note that your permitted activity is subject to a compliance inspection by a U. S. Army Corps of Engineers representative. Failure to comply with any terms or conditions of this authorization may result in the Corps suspending, modifying or revoking the authorization and/or issuing a Class I administrative penalty, or initiating other appropriate legal action. I hereby certify that the work authorized by the above referenced permit has been completed in accordance with the terms and condition of the said permit, and required mitigation was completed in accordance with the permit conditions. Signature of Permittee Date NOTIFICATION OF ADMINISTRATIVE APPEAL OPTIONS AND PROCESS AND REQUEST FOR APPEAL Applicant: ARE -NC Region No. 14, LLC; Oliver Sherrill I File Number: SAW -2015-00891 Date: 05/29/2015 Attached is: ISee Section below INITIAL PROFFERED PERMIT Standard Permit or Letter of ermission A ❑ PROFFERED PERMIT (Standard Permit or Letter ofpermission) B ❑ PERMIT DENIAL C ® APPROVED JURISDICTIONAL DETERMINATION D ❑ PRELIMINARY JURISDICTIONAL DETrRMINATION E SECTION I - The following identifies your rights and options regarding an administrative appeal of the above decision. Additional information may be found at or hq://www.usace.army.mil/Missions/CivilWorks/ReguIatoryProgramandPermits aspx or the Corps regulations at 33 CFR Part 331. A: INITIAL PROFFERED PERMIT: You may accept or object to the permit. • ACCEPT: If you received a Standard Permit, you may sign the permit document and return it to the district engineer for final authorization. If you received a Letter of Permission (LOP), you may accept the LOP and your work is authorized. Your signature on the Standard Permit or acceptance of the LOP means that you accept the permit in its entirety, and waive all rights to appeal the permit, including its terms and conditions, and approved jurisdictional determinations associated with the permit. • OBJECT: If you object to the permit (Standard or LOP) because of certain terms and conditions therein, you may request that the permit be modified accordingly. You must complete Section II of this form and return the form to the district engineer. Your objections must be received by the district engineer within 60 days of the date of this notice, or you will forfeit your right to appeal the permit in the future. Upon receipt of your letter, the district engineer will evaluate your objections and may: (a) modify the permit to address all of your concerns, (b) modify the permit to address some of your objections, or (c) not modify the permit having determined that the permit should be issued as previously written. After evaluating your objections, the district engineer will send you a proffered permit for your reconsideration, as indicated in Section B below. B: PROFFERED PERMIT: You may accept or appeal the permit • ACCEPT: If you received a Standard Permit, you may sign the permit document and return it to the district engineer for final authorization. If you received a Letter of Permission (LOP), you may accept the LOP and your work is authorized. Your signature on the Standard Permit or acceptance of the LOP means that you accept the permit in its entirety, and waive all rights to appeal the permit, including its terms and conditions, and approved jurisdictional determinations associated with the permit. • APPEAL: If you choose to decline the proffered permit (Standard or LOP) because of certain terms and conditions therein, you may appeal the declined permit under the Corps of Engineers Administrative Appeal Process by completing Section H of this form and sending the form to the division engineer. This form must be received by the division engineer within 60 days of the date of this notice. C: PERMIT DENIAL: You may appeal the denial of a permit under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer. This form must be received by the division •ren within 60 days of the date of this notice. D: APPROVED JURISDICTIONAL DETERMINATION: You may accept or appeal the approved JD or provide new information. • ACCEPT: You do not need to notify the Corps to accept an approved JD. Failure to notify the Corps within 60 days of the date of this notice, means that you accept the approved JD in its entirety, and waive all rights to appeal the approved JD. • APPEAL: If you disagree with the approved JD, you may appeal the approved JD under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the district engineer. This form must be received by the division engineer within 60 days of the date of this notice. E: PRELIMINARY JURISDICTIONAL DETERMINATION: You do not need to respond to the Corps regarding the preliminary JD. The Preliminary JD is not appealable. If you wish, you may request an approved JD (which may be appealed), by contacting the Corps district for further instruction. Also you may provide new information for further consideration by the Corps to reevaluate the JD. SECTION II - REQUEST FOR APPEAL or OBJECTIONS TO AN INITIAL PROFFERED PERMIT REASONS FOR APPEAL OR OBJECTIONS: (Describe your reasons for appealing the decision or your objections to an initial proffered permit in clear concise statements. You may attach additional information to this form to clarify where your reasons or objections are addressed in the administrative record.) ADDITIONAL INFORMATION: The appeal is limited to a review of the administrative record, the Corps memorandum for the record of the appeal conference or meeting, and any supplemental information that the review officer has determined is needed to clarify the administrative record. Neither the appellant nor the Corps may add new information or analyses to the record. However, you may provide additional information to clarify the location of information that is already in the administrative record. POINT OF CONTACT FOR QUESTIONS OR INFORMATION: If you have questions regarding this decision and/or the If you only have questions regarding the appeal process you may appeal process you may contact: also contact: District Engineer, Wilmington Regulatory Division, Attn: Eric Alsmeyer Mr. Jason Steele, Administrative Appeal Review Officer US Army Corps of Engineers, Wilmington District Raleigh Regulatory Field Office CESAD-PDO U.S. Army Corps of Engineers, South Atlantic Division 3331 Heritage Trade Drive, Suite 105 60 Forsyth Street, Room 10M15 Wake Forest, NC 27587 Atlanta, Georgia 30303-8801 Phone: (404) 562-5137 RIGHT OF ENTRY: Your signature below grants the right of entry to Corps of Engineers personnel, and any government consultants, to conduct investigations of the project site during the course of the appeal process. You will be provided a 15 day notice of any site investigation, and will have the opportunito participate in all site investiations. Date: Telephone number: Signature of appellant or agent. For appeals on Initial Proffered Permits send this form to: District Engineer, Wilmington Regulatory Division, Attn: Eric Alsmeyer, 69 Darlington Avenue, Wilmington, North Carolina 28403 For Permit denials, Proffered Permits and approved Jurisdictional Determinations send this form to: Division Engineer, Commander, U.S. Army Engineer Division, South Atlantic, Attn: Mr. Jason Steele, Administrative Appeal Officer, CESAD-PDO, 60 Forsyth Street, Room 1OM15, Atlanta, Georgia 30303-8801 Phone: (404) 562-5137 I, AUGUSTIN D. KEANE, PROFESSIONAL LAND SURVEYOR HEREBY CERTIFY THAT THIS SECTION OF WETLAND SURVEY WAS MADE UNDER MY DIRECT SUPERVISION AND THAT IT IS CORRECT TO THE BEST OF MY KNOWLEDGE, AND BELIEF; THAT THIS WETLANDS SURVEY WAS MADE IN ACCORDANCE WITH NCBELS WETLANDS MAPPING POLICY BP 1005A REV. 1; AND THAT THIS MAP MEETS THE REQyiREMENTS OF THE STANDARDS OF PRACTICE FO�uLA`Ni zS QV�jYING IN NORTH CAROLINA (21 NCAC 56.1600\,�, � j�GZ es t®0a� A ° ° A@� SE t tl L ° L 0 4474 °u 4f ° I, Augustin D. Keane, certify that this map was drawn under my supervision from an actual GPS survey made under my supervision and the following information was used to perform the survey: COPY 1. Class of Survey: Class A 2. Positional Accuracy: 0.10' 3. Type of GPS Field Procedure: NCGS VRS Network 4. Dates of Survey: January 9, and January 16, 2014 5. Datum/Epoch: NAD 83 (NSRS 2011 6. Published/Fixed-control use:Te 7. Geoid Model: Geoid 12A 8. Combined Grid Factor: See PI t VEZEIVED] 9. Units: US Survey Feet r ; ,l '' - ... � • ' , eZ Z 25 S PROJECT 60UNf7m N.C. PROFESSIONAL LAND SURVEYQ�2,L I444' \�-� ,,, v. + + + r r Point # Northing "This certifies that this copy of this plat accurately 0�, N/F ARE -NC REGION NO. LLC depicts the boundary of the jurisdiction of Section 404 of the Clean Water Act as determined by the DURHAM COUNTY PN PI undersigned on this date. Unless there is a change in 0748-03-12-4785 the law or our published regulations, the determination DB 6902 PG 392-396 of Section 404 jurisdiction may be relied upon �` PB 11 PG 362-365 for a period not to exceed five (5) years from this date. , 592,300 SF The undersigned completed this determination utilizing 13 60 ACRES the appropriate Regional Supplement to the 1987 U.S. Army 782175.27 Corps of Engineers Wetlands eli eation Manual." COMPMO POW Regulatory Official: Title: �o . _ I% ANNUAL CWNCE Date: FI 0012LINE USACE Action ID No.: r l MAR 0 2 2015 RALEIGH REGULATORY 7' ; FIELD OFFICE I N: 782290.22 / E: 2091758.69 / f r0 Co- 5'0-1-Mp�n POINT Vii" W 675 57"L � TIS TO QIP �! 59* 54} 26 W I'loodplain �oundarL Iine5 5hown were provided bH the II[ NSF N: 782236,19 t poi/ice ARE -NC REGION NO. 14 LLC E 2091799.26 North Carolina I'loodplain Mappinq program, I DURHAM COUNTY PIN ) / All floodplain boundar Iine5 are effective a 21 0748-03-02-7196 p fftMi DB 6902 PG 392-396 5D-1 TT CULVE T START AW8 2006 and reflect boundaries 5hovn on PFIPM / PB 11 PG 362-365 �/ r 3120074800J, x 1,857,024 SF 42.63 ACRES SD -2 AW7FT O� 1 Horizontal Vatum for floodplain NAV 83, Vertical Patum for floodplain NAVP 88, MTLANI25 POUN17A1'1' ACI?E5 - .0027 APEA - 115,72 5Q. Ff• / ✓1� # r on r /, C p'OJ�Cr 5 as / OUNnApy` �' '�' ✓y THIS WETLANDS SURVEY SUPERCEDES THE SURVEYS OF THE SAME NAME DATED 1/8/15,1/16/15, AND 1/22/15, , SEALED BY AUGUSTIN D KEANE, PLS �1���O 'G `000J9' 04) � \9 l N'• Q60 09,6a` 1 EXISTING CONC�TE ,� � •�„ MONUMENT I IN�AI? POOTAG� Of 5TI?�AM MOM COMPUTED POINT AW/8FT 5P-1 TO COMPUT�b POINT - 159,12' O ... EXISTING IRON PIPE N/F... NOW OR FORMERLY QO ...COMPUTED POINT ...SD FLAGGING 60" RCP 1 % ANNUAL CHANCE FLOODLINE ----- - FLOODWAY ...WD FLAGGING ■ ...EXIST. CONC. MONUMENT . „ ,n on .. . . PROJECT BOUNDARY - - - - RW LINE - --- --- TIE LINE GRAPHIC SCALE / SD -3 AW8FT ~� WD -1 TTT, Sb� OMPUTEI7 POINT I / } �1 j WD -Z/' WD -4 fir o i mow= J SD -4 AW00 ? J v to e � 1 j 1 N:782132,57 E: 2041660,92 i t � r j � r �ca oja �(D m 00 t4 � 0 Z�� �"z 0LL LL0 z¢- 0 25 50 100 1 INCH = 50 FEET Line Table Line ## Point Table Length Point # Northing Fasting Description 90001 782236.19 2041749.26 SD --1 TTCULVERT START 90002 782210.27 2041725.73 SD -2 AW7FT 90003 782180.88 2041701.41 5D-3 AW8FT 90004 782175.27 2041701.24 WD -1 TT SD 90005 782164.25 2041696.60 WD -2 90007 782159.70 2041688.46 WD -3 TT SD 90008 782162.17 2041685.54 COMPUTED POINT 90006 782132.57 2041660.42 SD -4 AW10FT 94 782115.48 2041645.63 SD -4 AW8FT O ... EXISTING IRON PIPE N/F... NOW OR FORMERLY QO ...COMPUTED POINT ...SD FLAGGING 60" RCP 1 % ANNUAL CHANCE FLOODLINE ----- - FLOODWAY ...WD FLAGGING ■ ...EXIST. CONC. MONUMENT . „ ,n on .. . . PROJECT BOUNDARY - - - - RW LINE - --- --- TIE LINE GRAPHIC SCALE / SD -3 AW8FT ~� WD -1 TTT, Sb� OMPUTEI7 POINT I / } �1 j WD -Z/' WD -4 fir o i mow= J SD -4 AW00 ? J v to e � 1 j 1 N:782132,57 E: 2041660,92 i t � r j � r �ca oja �(D m 00 t4 � 0 Z�� �"z 0LL LL0 z¢- 0 25 50 100 1 INCH = 50 FEET Line Table Line ## Direction Length L1 S 42'13'11" W 35.01 L2 S 39'36'12" W 38.15 L3 N 40'18'53" E 24.53 L4 S 40'18'53" W 38.83 L5 S 1'44'53" W 5.61 L6 S 22'49'56" W 11.96 L7 S 60'50'26" W 9.33 L8 N 49'41'07" W 3.82 L9 S 40'52'56" W 22.60 suRvevED av:WETLANDS ESP Associates, P.A. LOCATION SURVEY: PREPARED FOR: DATE: 01/016!15 SCALE: 1" = 50' ,e 5121 KINGDOM WAYO'BRIEN/ATKINS SUITE ARE -NC REGION No. 14 LLC ASSOCIATES, PA DRAWN BY: CHECKED BY: RALEIGH, NCC 2 27607 � N.P.B K.D.M E P PHONE 919.678.1070 6 DAVIS DRIVE 5001 S. MIAMI BLVD. -DESCRIPTION- WETLANDS SURVEY �� rr FAX 919.677.1252 RESEARCH TRIANGLE PARK, NC 27501 DURHAM NC 27703 SHEET .€' LICENSE NO. C-0587 WWW'LSPASSocInIES.coM DURHAM COUNTY, NORTH CAROLINA DURHAM COUNTY NORTH CAROLINA 1 OF 1 �o T C? DOyam.-; fl Office Use Only: Corps action ID no. DWQ project no. Form Version 1.4 January 2009 Page 1 of 10 PCN Form — Version 1.4 January 2009 Pre -Construction Notification (PCN) Form A. Applicant Information i. Processing 1 a. Type(s) of approval sought from the Corps: Section 404 Permit ® Section 10 Permit 1 b. Specify Nationwide Permit (N\/\/P) number: 13 & 7 or General Permit (GP) number- umber:1c. 1c. Has the NWP or GP number been verified by the Corps? ❑ Yes ® No 1d. Type(s) of approval sought from the DWQ (check all that apply) - 0 401 Water Quality Certification — Regular ® Non -404 Jurisdictional General Permit ❑ 401 Water Quality Certification — Express ® Riparian Buffer Authorization 1 e. Is this notification solely for the record because written approval is not required? For the record only for DWQ 401 Certification: ❑ Yes ® No For the record ❑ Yes only for Corps Permit: ® No 1f. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? If so, attach the acceptance letter from mitigation bank or in -lieu fee program. ® Yes ® No 1 g. Is the project located in any of NC's twenty coastal counties. If yes, answer 1 h below. ❑ Yes ❑X No 1 h. Is the project located within a NC DCM Area of Environmental Concern (AEC)? ❑ Yes ® No 2. 2a. 2b. Project Information Name of project: ARE -NC Region No. 14, LLC Davis Drive Entrance Road County: Durham 2c. Nearest municipality / town: Durham 2d. Subdivision name: Research Triangle Park, Property Address 6 Davis Drive 2e. NCDOT only, T.I.P. or state project no: N/A 3. Owner Information 3a. Name(s) on Recorded Deed: ARE -NC Region No 14 LLC 3b. Deed Book and Page No. DB 6902 PG 392 3c. Responsible Party (for LLC if applicable): Mr. Oliver Sherrill, Senior Vice President, Regional Market Director 7020 Kit Creek Road, Suite 100 3d. Street address: 3e. City, state, zip: Research Triangle Park, NC 27709-3329 3f. Telephone no.: 919-313-6645 3g. Fax no.: 919-993-3439 3h. Email address: osherrill@are.com Page 1 of 10 PCN Form — Version 1.4 January 2009 4. Applicant Information (if different from owner) 4a. Applicant is: ❑ Agent ❑ Other, specify: 4b. Name: 4c. Business name (if applicable): 4d. Street address: 4e. City, state, zip: 4f. Telephone no.: 4g. Fax no.: 4h. Email address: 5. Agent/Consultant Information (if applicable) 5a. Name: Becky L. Ward 5b. Business name (if applicable): Ward Consulting Engineers 5c. Street address: 4805 Green Road, Suite 100 5d. City, state, zip: Raleigh, NC 27616 5e. Telephone no.: 919-870-0526 5f. Fax no.: 919-870-5359 5g. Email address: bward@wce-corp.com Page 2 of 10 B. Project Information and Prior Project History 1. Property Identification 1 a. Property identification no. (tax PIN or parcel 1 b. Site coordinates (in decimal degrees): Latitude: 35.8991 0748-03-02-7196 Longitude: -78.859 1 3 c. Property size: 42.38 acres 2. Surface Waters 2a. Name of nearest body of water to proposed project. Burdens Creek Tributary 4 2b. Water Quality Classification of nearest receiving water: WS -V; NSW 2c. River basin: Cape Fear . Project Description 3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application. Please see documentation attachment 3b. List the total estimated acreage of all existing wetlands on the property: 0.823 3c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property: 2,205 3d. Explain the purpose of the proposed project. Please see documentation attachment 3e. Describe the overall project in detail, including the type of equipment to be used. Please see documentation attachment 4. Jurisdictional Determinations 4a. Have jurisdictional wetland or stream determinations by the ❑ Yes ® No ❑ Unknown Corps or State been requested or obtained for this property / roject(including all priorphases) in thepast? Comments: Meeting with COE at site held on 12-10-14 to review 4b. If the Corps made the jurisdictional determination, what type Preliminary ❑Final of determination was made? y 4c. If yes, who delineated the jurisdictional areas? Agency/Consultant Company: ESP Associates PA see map Name (if known): Cory Darnell Other: 4d. If yes, list the dates of the Corps jurisdictional determinations or State determinations and attach documentation. 5. Project History 5a. Have permits or certifications been requested or obtained for ®Yes ®No El Unknown this project (including all prior phases) in the past? 5b. If yes, explain in detail according to "help file" instructions. 6. Future Project Plans 6a. Is this a phased project? ® Yes ® No 6b. If yes, explain. Yes additional buildings are planned for the site. Page 3 of 10 PCN Form —Version 1.4 January 2009 C. Proposed Impacts Inventory 1. Impacts Summary 1 a. Which sections were completed below for your project (check all that apply): X] Wetlands ❑X Streams — tributaries ❑X Buffers ❑ Open Waters ❑ Pond Construction 2. Wetland Impacts If there are wetland impacts proposed on the site, then complete this question for each wetland area impacted. 2a. Wetland impact number Permanent (P) or Temporary T 2b. Type of impact 2c. Type of wetland 2d. Forested 2e. Type of jurisdiction Corps (404,10) or DWQ (401, other) 2f. Area of impact (acres) W1 P Fill Bottomland Hardwood Forest Yes/No Corps 0.0027 W2 - Choose one Choose one Yes/No - W3 - Choose one Choose one Yes/No - W4 - Choose one Choose one Yes/No - W5 - Choose one Choose one Yes/No - W6 - Choose one Choose one Yes/No - 2g. Total Wetland Impacts: 0.0027 2h. Comments: W1: The wetland impacted is located at the current pipe outlet and will be filled in when the pipe is extended for the proposed drive. 3. Stream Impacts If there are perennial or intermittent stream impacts (including temporary impacts) proposed on the site, then complete this question for all stream sites impacted. 3a. Stream impact number Permanent (P) or Temporary (T) 3b. Type of impact 3c. Stream name 3d. Perennial (PER) or intermittent (INT)? 3e. Type of jurisdiction 3f. Average stream width (feet) 3g• Impact length (linear feet) S1 P Culvert Burdens Crk Trib 4 PER Corps 20 94 S2 P Stabilization Burdens Crk Trib 4 PER Corps 20 50 S3 - Choose one - - S4 - Choose one - - S5 - Choose one - - S6 - Choose one - - 3h. Total stream and tributary impacts 144 3i. Comments: S1 Permanent Pipe extension for the development driveway S2: Riprap outlet protection and stream bank stabilization Page 4 of 10 PCN Form — Version 1.4 January 2009 4. Open Water Impacts If there are proposed impacts to lakes, ponds, estuaries, tributaries, sounds, the Atlantic Ocean, or any other open water of the U.S. then individually list all open water impacts below. 4a. Open water impact number Permanent (P) or Temporary T 4b. Name of waterbody (if applicable) 4c. Type of impact 4d. Waterbody type 4e. Area of impact (acres) 01 - Choose one Choose 02 - Choose one Choose 03 - Choose one Choose 04 - Choose one Choose 4f. Total open water impacts 4g. Comments: 5. Pond or Lake Construction If pond or lake construction proposed, then complete the chart below. 5a. Pond ID number 5b. Proposed use or purpose of pond 5c. Wetland Impacts (acres) 5d. Stream Impacts (feet) 5e. Upland (acres) Flooded Filled Excavated Flooded Filled Excavated Pi Choose one P2 Choose one 5f. Total: 5g. Comments: N/A 5h. Is a dam high hazard permit required? ❑ Yes ❑ No If yes, permit ID no: 5i. Expected pond surface area (acres): 5j. Size of pond watershed (acres): 5k. Method of construction: 6. Buffer Impacts (for DWQ) If project will impact a protected riparian buffer, then complete the chart below. If yes, then individually list all buffer impacts below. If any impacts require mitigation, then you MUST fill out Section D of this form. 6a. Project is in which protected basin? ❑ Neuse ❑ Tar -Pamlico ❑ Catawba ❑ Randleman Q Other: 6b. Buffer Impact number— Permanent (P) or Temporary 6c. Reason for impact 6d. Stream name 6e. Buffer mitigation required? 6f. Zone 1 impact (square feet) 6g. Zone 2 impact (square feet B1 P Pipe installation Burdens Creek Tributary 4 No 5,640 31760 B2 T Equipment Access Burdens Creek Tributary 4 No 1,700 800 B3 - Yes/No B4 - Yes/No B5 - Yes/No B6 - Yes/No 6h. Total Buffer Impacts: 7,340 4,560 6i. Comments: B1: Permanent buffer impacts are associated with the extension of the existing pipe for the driveway. B2: Temporary impacts will occur during construction by equipment and grading the buffers will be replanted. Page 5 of 10 D. Impact Justification and Mitigation 1. Avoidance and Minimization 1 a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing project. Avoidance of the stream can not be accomplished it is required that this entrance be placed directly across Davis Drive from an existing road. The culvert extension length has been minimized as much as possible with a headwall placed at the end. Additionally the roadway width has been set to the minimum widths. 1 b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques. The limits of disturbance have been set to allow for the minimal distance for construction. The pipe and stream stabilization work will be preformed from the top of the stream bank. No equipment will be placed in the channel. A stream pump around will be used for construction. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? ❑ Yes ❑X No 2b. If yes, mitigation is required by (check all that apply): ❑ DWQ ❑ Corps 2c. If yes, which mitigation option will be used for this proJ project? ❑ Mitigation bank El Payment to in-lieu fee program ❑ Permittee Responsible Mitigation 3. Complete if Using a Mitigation Bank 3a. Name of Mitigation Bank: 3b. Credits Purchased (attach receipt and letter) Type: Choose one Type: Choose one Type: Choose one Quantity: Quantity: Quantity: 3c. N/A Comments: 4. Complete if Making a Payment to In-lieu Fee Program 4a. Approval letter from in-lieu fee program is attached. ❑ Yes 4b. Stream mitigation requested: linear feet 4c. If using stream mitigation, stream temperature: Choose one 4d. Buffer mitigation requested (DWQ only): square feet 4e. Riparian wetland mitigation requested: acres 4f. Non-riparian wetland mitigation requested: acres 4g. Coastal (tidal) wetland mitigation requested: acres 4h. Comments: 5. Complete if Using a Permittee Responsible Mitigation Plan 5a. If using a permittee responsible mitigation plan, provide a description of the proposed mitigation plan. Page 6 of 10 PCN Form — Version 1.4 January 2009 6e Buffer Mitigation (State Regulated Riparian Buffer Rules) — required by ®WCC 6a. Will the project result in an impact within buffer mitigation? a protected riparian buffer that requires Yes ® No 6b. If yes, then identify the square feet of impact to each zone amount of mitigation required. of the riparian buffer that requires mitigation. Calculate the Zone 6c. Reason for impact 6d. Total impact (square feet) Multiplier 6e. Required mitigation (square feet) Zone 1 3 (2 for Catawba) Zone 2 1.5 6f. Total buffer mitigation required: 6g. If buffer mitigation is required, discuss permittee responsible riparian buffer what type of mitigation restoration, payment into is proposed (e.g., payment an approved in-lieu fee fund). to private mitigation bank, N/A 6h. Comments: Page 7 of 10 E. Stormwater Management and Diffuse Flow Plan (required by DWQ) 1. Diffuse Flow Plan 1 a. Does the project include or is it adjacent to protected riparian buffers identified within one of the NC Riparian Buffer Protection Rules? ® Yes ❑ No 1 b. The project. If yes, then is a diffuse flow plan included? If no, explain why. project was grandfathered in because part this project is a site plan amendment for an overall See abbreviated SIA for the proposed driveway included with this submittal package. ❑ Yes ® No 2. Stormwater Management Plan 2a. What is the overall percent imperviousness of this project? 26% 2b. Does this project require a Stormwater Management Plan? ® Yes ❑ No 2c. If this project DOES NOT require a Stormwater Management Plan, explain why: 2d. If this project DOES require a Stormwater Management Plan, then provide a brief, narrative description of the plan: A stormwater SIA was prepared for buildings 1 & 2, roads, and parking- BMP's were provided. The first 10 pages of the 308 page document dated October 24,2014 has been attached along with the entire document on a CD. The approval letter is included in the PCN submittal package. A SIA was submitted to the Durham County on 2-16-2015 for the proposed entrance as an amendment. This amendment does not include any BMP's. A buy down is proposed for Nitrogen. This amendment is currently under review with Durham County. 2e. Who will be responsible for the review of the Stormwater Management Plan? Durham County 3. Certified Local Government Stormwater Review 3a. In which localgovernment's Jurisdiction is thisproject? Durham County Z Phase II 3b. Which of the following local) -im plemented stormwater management programs apply (check all that apply): ® NSW ❑ USMP ® Water Supply Watershed ❑ Other. 3c. Has the approved Stormwater Management Plan with proof of approval been ® Yes ❑ No attached? 4. DWQ Stormwater Program Review ❑ Coastal counties ❑HQW 4a. Which of the following state -implemented stormwater management programs apply (check all that apply): ❑ 0 R ®Session Law 2006-246 ❑ Other. 4b. Has the approved Stormwater Management Plan with proof of approval been attached? ® Yes ❑ No 5. DWQ 401 Unit Stormwater Review 5a. Does the Stormwater Management Plan meet the appropriate requirements? ® Yes ❑ No 5b. Have all of the 401 Unit submittal requirements been met? ® Yes ❑ No Page 8 of 10 PCN Form —Version 1.4 January 2009 F. Supplementary Information 1. Environmental Documentation (DWQ Requirement) 1 a. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land? ®Yes ❑X No 1 b. If you answered "yes" to the above, does the project require preparation of an environmental document pursuant to the requirements of the National or State ❑ Yes ❑ No (North Carolina) Environmental Policy Act (NEPA/SEPA)? 1 c. If you answered "yes" to the above, has the document review been finalized by the State Clearing House? (If so, attach a copy of the NEPA or SEPA final approval Ietter.) ®Yes ❑ No Comments: 2. Violations (DWQ Requirement) 2a. Is the site in violation of DWQ Wetland Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), DWQ Surface Water or Wetland Standards, or Riparian Buffer Rules (15A NCAC 2B .0200)? ❑ Yes ❑X No 2b. Is this an after -the -fact permit application? ❑ Yes ® No 2c. If you answered "yes" to one or both of the above questions, provide an explanation of the violation(s). 3. Cumulative Impacts (DWQ Requirement) 3a. Will this project (based on past and reasonably anticipated future impacts) result in additional development, which could impact nearby downstream water quality? ❑ Yes ® No 3b. If you answered "yes" to the above, submit a qualitative or quantitative cumulative impact analysis in accordance with the most recent DWQ policy. If you answered no, provide a short narrative description. 4. Sewage Disposal (DWQ Requirement) 4a. Clearly detail the ultimate treatment methods and disposition (non -discharge or discharge) of wastewater generated from the proposed project, or available capacity of the subject facility. Sewage disposal will e conveyed to the municipal system for treatment. Page 9 of 10 PCN Form —Version 1.4 January 2009 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or ❑ Yes ❑X No habitat? 5b. Have you checked with the USFWS concerning Endangered Species Act 0 Yes ❑ No impacts? 5c. If yes, indicate the USFWS Field Office you have contacted. Raleigh ES Field Office 5d. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? ECS Carolinas, LLP provided a Limited NEPA Database Review Report and field reconnaissance on November 6, 2014 for the site. The report is attached. 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as essential fish habitat? ❑ Yes Q No 6b. What data sources did you use to determine whether your site would impact Essential Fish Habitat? The project is located in an urban stream. Please see ECS Carolinas, LLP report attached. 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation ❑ Yes ❑X No status (e.g., National Historic Trust designation or properties significant in North Carolina history and archaeology)? 7b. What data sources did you use to determine whether your site would impact historic or archeological resources? The NC State Historic Preservation Office was contacted. Please see letter in ECS Carolinas, LLP report attached. 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA -designated 100 -year floodplain? ❑X Yes ❑ No 8b. If yes, explain how project meets FEMA requirements: A CLOMR document has been prepared and is currently being reviewed by the City of Durham for concurrence before it will be submitted to FEMA for approval. 8c. What source(s) did you use to make the floodplain determination? (nc.floodmaps.gov) Mr. Oliver Sherrill Applicant/Agent's Printed Name Applican gent's Signature Date (Agent's signature is valid only if an authorization letter from the applicant isprovided.) Page 10 of 10 Documentation for Pre -Construction Notification (PCN) Form ARE -NC Region No. 14, LLC Davis Drive Entrance Road, Research Triangle Park Durham County B Project Information and Prior Project History 3a. Project Description The project is located at 6 Davis Drive, Research Triangle Park, in Durham County. A proposed building and parking areas are planned to be developed on site along with an entrance Road that will serve the site and the existing Hamner Building on the adjacent property. The entrance drive will require the extension of an existing 60 -inch culvert that passes under Davis Drive flowing northeast to southwest on Burdens Creek Tributary 4 a FEMA regulated stream. The pipe is corrugated metal on the upstream end (east side of the road) and reinforced concrete pipe (RCP), on the downstream end. It is assumed the pipe was extended in the past for road improvements, and the culvert was extended with different pipe material. The proposed entrance drive is on the west side of Davis Drive, immediately across the road from Entry Drive as required by NCDOT. The culvert extension has been coordinated with NCDOT for future upgrades. The current 60 inch culvert is not large enough to handle the 50 year storm event and therefore is anticipated to be upgraded to a larger pipe in the future. The extension therefore is proposed to be completed with a junction box and larger pipe arch to the outlet. In the future NCDOT will be able to upgrade the 60 inch pipe to this larger pipe arch and tie into the constructed junction box. The pipe arch size and proposed design has been coordinated with NCDOT. 3d. Explain the purpose of the project. The proposed project is located in Durham, North Carolina. The proposed driveway entrance will be located approximately 1700 feet north of 1-40 along Davis Drive. The driveway is required to be installed directly opposite an existing roadway Entry Drive. This location requires the extension of an existing 60 inch culvert under Davis Drive on Burdens Creek Tributary 4. An alternative location for the proposed driveway is not possible due to the requirement of NCDOT to align the proposed driveway directly across Davis Drive from Entry Drive which is an existing road. Therefore encroachment into Burdens Creek Tributary 4 is required to extend the existing pipe to maintain stormwater conveyance across Davis Drive. The proposed entrance drive is required for the proposed development to meet City development standards to handle the additional traffic volume expected for the property and emergency vehicles. Encroachment is required into Burdens Creek Tributary 4, for the proposed entrance drive due to the location required by NCDOT. The pipe extension has been minimized as much as possible to only accommodate the needed driveway width for the development. The outlet pipe extension has also been sized and coordinated with NCDOT to provide for future upgrade of the existing 60 inch pipe across Davis Drive to prevent future disturbance to Burdens Creek Tributary 4. PCN Documentation 1 Davis Drive Entrance Road RTP Durham County 3e. Describe the overall project in detail, including the type of equipment to be used. The project consists of the construction of parking lots buildings and an entrance drive over Burdens Creek Tributary 4. The proposed driveway will be constructed over the existing location of the outlet of the 60 inch culvert. Therefore, the culvert is planned to be extended. Approximately 10.5 linear feet of 60 inch pipe will be installed from the current pipe outlet to the proposed junction box. This junction box is proposed to be installed in the entrance to provide NCDOT with maintenance access to their pipe across Davis Drive. The junction box has also been provided and sized to serve as a tie in location for a larger pipe arch in the future when the existing 60 -inch pipe is upgraded. The junction box will also prevent future disturbance to Burdens Creek Tributary 4 in the future. The proposed pipe out of the junction box has been designed in coordination with NCDOT as a pipe arch in anticipation of future NCDOT pipe upgrades to the existing 60 -inch pipe under Davis Drive. The proposed parking lots and buildings have been placed outside of the disturbance of any wetlands, jurisdictional streams, and stream buffers on the project site. The only wetland, stream, and buffer impacts will occur at the proposed entrance drive with the pipe extension. The equipment to be used in the project is earth moving equipment and various other support apparatuses. Construction equipment may include hydraulic excavators, compactors, bulldozers, skid steer loaders, and dump trucks to load and unload materials. The construction equipment will enter from the public street and will perform all construction within a defined limit of disturbance. Only trees obstructing the creek bank within the pipe extension and bank stabilization areas as shown on the plans will be removed. PCN Documentation 2 Davis Drive Entrance Road RTP Durham County Appendix A Photo Log Location Map Wake County Soils Map Watershed Map Impact Map a- 1 t * qn-* t `yti Ikkk - y�� Location, Soils, and Watershed Maps N ta Si Fill International I4ng R IF Sand Courts + f Out Flight Venture Center IBM + PROJECT LOCATION 6 DAVIS DRIVE RESEARCH he Hamrma Institutes , Syngenta Biotechnology TRIANGLE PARK `'hscienees N ci "asr tn'vtO-'p�Y{ US Almy w W 4 at Q ark Offices ar n` a y G t] Q 4k r ' Bank of America J'f r� t� Wells I ergo Bank rvtt gb Technologies t"Y , ARE -NC REGION NO 14, LLC DAVIS DRIVE ENTRANCE ROAD, RTP PROJECT LOCATION MAP DURHAM COUNTY, NORTH CAROLINA DATE: MAR 31, 2015 PIN #: 0748-03-02-7196 PARCEL ID#: 157816 WARD CONSULTING ENGINEERS, PC 42.38 ACRES DB 6902 PG 392 �� 4805 Green Road, Suite 100 (919) 870-0526 ��� Raleigh, NC 27616 FAX (919) 870-5359 L: January 19, 2015 Override 1 Railroads City of Durham 13 Neighboring Counties Davis Drive Location Map t Iq r, � I ci)ifl pl+�g� I d I ;tom x •"� � �' 1 rrV�ZF ff+ y 141 A 1"o QfNC� T. Vg ���' k ! 4 0-1 filFiRlltlS�r.t��� ��. J e3Sl'p o• 1:18,056 0 0.150.3 0.6 mi 0 0.25 0.5 1 km Sources: Esri, HERE, Del-onme, USGS, Inteamap, increment P Corp., NRCAN, Esri Japan, METI, Esri China (Hong Kong), Esd (Thailand), TomTom, Mapmylndia, © OpenStreetMap contributors, and the GIS User Community Information depicted hereon is for reference purposes orgy and is compiled from the bestavailable sources. The City of Durham/Durham County assumes no responsbilly for errors ar'singfrom use or misuse of this map. 11� % /IDI . I -- s _ 37g Q' yApNBT 4.# -�.•.. /'/ - ,♦ , ' � - / YAG • C� 00 I �#-■ I +' _ / W 0 FORMER . '��'. ,-_'' C\2 Lo -'A., � 1 - - '" �' SYNGE TA TECHNO GY INC. ��'••.. <' .I 4,•,\r,,. BURDEN CR K `, of J Lo C0 �'. r„• "i 1 p d P #: 48-03- -3790 . �\•�*'•..� / 1 .• ,�' ,'I \\ • O Lo •, - ~ � TR UTARY t _ 1% /� � AR 57806 ' I� ` 14 I �y„�” •nr` ',a : !: , ds� ��. 3/? �w- - • �' r ,� � W (J��\� 5632 APG: 9 6 .\,•`��'•i.� .��'#•. . �' 1,` --- � S1_ NOW OR FORMERLY: i I I I �� �0 s M1 11 - .� = \� NE G: 202 '' - _ _ _ - -_ PROPOSED co co ♦ ,�„ �� NED: SCH011K---,”--� STREAM r/1 �.-. .,, •. o N OF XTILIE C EMISTS OCIADTIOOLORIST I o s ♦. 1,--,,r /-------------------- -- -- - ''�..-- - , ._1+ ; _ �-----------/--- BUFFER O O _ . I ' '4U CO ERC L IC ♦ ^^ ,, PIN#: 0748-03-2 66 Q - 1 �• ,�� ♦ •\�-- ����... ---- ------ " - ------ -_ --------- W r-1 �-1 PARCEL ID#:157821 W .,,'.,,+ _ '�.. �' 1 ` \---- '•s --� \ __ p - - �„ �.,_„ O O 9.99 ACRES 0 I ,, - ,.*, Z Q O F - . - — - - - - -- --------- : 290 PG: 83 �� b' •" O - - - _ ` ---� D O'r _ - �4-- L -L-' I LPR E RCP USE: MMER N \���0` �i -\ -- - \�„••,,.. �*► ♦, ,� a I _-----------��� -- - �P \ �P I - � ! STING FE 4129 - - - - - - - - - - - - - = w = M � `—n+ ----- - \, •• - _ _ _ - - -- -_ kQ� T� ---- - -- - _ _ -�- - 1- - -- -- - -- - _ _-_- - - - --- - - - -� _ -� - - _ _ \\\tel- _ _ —�- _ •^�\ "';� ------�____ =_-------- _ INV= Q\J V I V V ___ - - — 8 ;,.,. y\5;� 78 LF OF PR ' - _ _ \� DAVI DRIVE _ / � \ — tet. 1999 — 1 ' PUB IC R/WJ� EFFECTIVE 100 ',yAr _ _ _ �- _ I'-} _ _, PIPE AR _--- \-- \\\ \ YEAR OODPLAIN PROPOSED - WETLAND DAVIS DRIVE SOUTF`BQUND _ - -- -- ---- _ _ _-_---_ -- ---- _ \ _ - --19 �,;;_ � .,,-��•' �.�,.�., _ �,.� 0.002 ACRES � _ _ �\.,''/ � ♦ `\ �� f_�- _ XTSTJ E -4- - _ - - - _ - - ----- --------------------- I \ \ 1 _ _ :�= J ���y--rv-;�� - ; / �\ EFFECTIVE FEMA `^ Iv��. --- ------ --- I ', �, -_��:,,,,---,,*v/ _-\ \ \ \\ \. �\\ \ / +,i 4 , \'� ` ♦ \ / , J ---31'x__-___ I I `,♦ 1 `\�\�)� ` \ `\3? \ J \\ \3ff �.•.,�rs -`�-\ k ` 100 YEAFj FLO 4PLpjIN „ _---- -- I I ` 11 ' I / '4 � \\\sL /�\\ --- j) j\a ,--- '-----3;z--==_ i I I, II\\i 1/i- \ �, \ ` \\2 \O `B LTi `-�` \ \ o l --- \ ., `I \\�[,r/� II'�.�- `\� ` \\ ` \ \ \\ ` �\ P T-P\R JECT n. �`., ,, 1 / / J/rn \ 3 ,; ' --------- --_ - ONOW OR OR \ \� 1, V/ - 1...-., \ \ \ - - /, - , / \ �♦ \3p \ \-`-_ / �\ /� III \ 1 `� /�---_--- , ///'' __ --- \ I I ` I \ �� >L�1\ I (o \ Ip,- <y a � 11.1 `, �\ I QO ��14R �L�00 LAIN � , �'\ \ � . : I I � _J/- _ / II ,--- _- ---- ' i � A F N TH CA OLIN h./ \ "�” ' / - sos_- I I \ `\ / > \ \ \ Vii, \ I ♦�. , / 1 / \ '\ \d \ \ \ r \ I \ `�/ \III #: 0 8-03-13-6 96 .^\ ��iV/^ 1I��\�\ �\TO B`APPROVED \------�' S0 \PROPOSED I ' / I ) �\ '-- �� < < <,y )// \ l a ,/ -3p „_, . r _ _ _ I !'� 315 % PARCEL ID 157820 �` ` — -_ ( u1 ♦ \ • • \ 11 - - 1 �// '�7 _ \ \_ STIP- ERI 1 I :i / \ tee• 1, ^\ ` > - ,' \ QC:_! _ �/i� \ C9 Q / / / ,_-- _ \ �„ I„' 7.95 ACR �,,/ > \?�y - 1 \ \ \ \ 1 1 6., ,-- \ - / /�\ \ / / / / *' \ �, -\ ` DB: 5655 PG: 689 I •� ,) ti\\ �� ) / \- 1 I -� / r� / \� \ \ I 3 / ■ '`�_ 4l / \ ��\ `\ > / 1 J I- �` \ / 1 ♦ b°/I `� .-345�a \\ �\ \ � ---- 309_----� % % % ' \\ /�',, _./`\ ZONED: RSCH 1 v , � / ___---__ I\ �\ ( •� . , . ,� ~` i \ - / , , \ \ , \ , EXISTING USE:. RESEARCH �\ - �-!�--- -)� / - / , o a_ - lw �- -- - _�\------_�l �- / l - �* \ %* .::./ \\ \\ 34e_ i i \ \\ 1 I 'STREAM �` _ �- \1 �// P. \5 l / 11\� \\ i 1 \ - SET ♦.. of..::;:' ` �.,« ,v \\- \ 4_ - _ BUFFER 1 •� . \`I L^�//, �% --- \ �J\ \ W, C� ( 1x \\ \ \,I '---\ JI• - N, t•.-1:i:Y:;.;;;' r��J� \ - ,�A--T EAM '�-� _- 1 1 \ //// .-_ -\ 111 I l \\\\ \\ ai l \ �Z l ♦ / ”'""' ' ` _ - B 1'I \\ 1 \ �:/ 1.0 ' , 1 ///// / /, -1 M \ 1 % 1\\ 3, ` m \ \ \ ---- i ..' \ < ♦ / " - - , I // - - 0 1 I �/ / !� 1 I 1 � \ 6-�- \ ,-' \ \\\\�\ % \\ \ -`-- \ ft }p \ ,��3 �O \ :'::-': �:...... ;:.. - -..... _ ` ---/ IIS II \ \\ �,,♦;I\- \\ I \ / / / �! > `� \ ;;1 EX. HAMNER BUILDING `` \ �_� \ 1\`\ \� ter,` \\\\ �..�� \Nkl �........ ;�'4 � - ;ItI`.---\ `\ I � II / � � / ' / ^ice 1 r \ \ \ 1 ARE -NC REGION NO 14 LLC ` �--- - -\ - - `' �` ,''• - I 'I / / / / \ 1 \\ 1Z �\ - \ \ �\ \ \ \ 1 I \ , i / I JJ///// /// � I I -� \ l\\`1 / I \ ` \ \` \ \ \ \ :,. �-:::7;' 1, 1I \ - \ 1 1 :,,_ ' / / / ///�- 1 ' PIN#: 0748-03-12-4785 / L \ \ \\ 1� \ �, \ ♦ %,, WETLAND .�\ 11 I `\ 1 1 3/3 '°I �--- I I, Ill //i ( 1 �\, 1�I l- I \ \ \ \ \ \ ;: I I \ \ I �' / I \/ /'/ I `j PARCEL ID#: 212285 \ \ �- ;-- \\ \ \ \ \ ♦ ;:.,,; I \ \ 1 \ 1 , 1 / /,-)'/ i' /� oo \ / III I �' 1 ( 1 \ \ - - '� \ \ \, \ \� \ \ ♦, 0.66 ACRES 1 , \\ \I 1 1 1 / /00 / //l 1 , J.\ 13.60 ACRES / / 1e V \I\ \ \` \� -, \ I 1.' i/ 1 I i' \ 111 I DB: 6902 PG: 392 1 1�h , \\--- (I ,�.�\,', \�\'A, -' \ \ ♦ �% , 1► `��:�,; � _ :.-. . •.l : ;; a ■ �\If \ \`\ `\ 1 11 � 1 i e / /, / I PB: CD001 1 PG: 362 , / \7 _ \ \ - ♦ « \ 11 l 1 �' �' �� / I ZONED: RSCH �Q`I I / / / ,-�,/ /, -� \ `a,\ ` \ \- ♦ I �:: ;:..;:: ::...: ► I \� 1 1 / / , / `- i /' // 1'(1 � I USE: LABORATORY/RESEARCH t x- I I i I // �/ 1� \\ `I I, !v� C.� \\ ,I 1<`. - I \\` ;`` `k • \ A �� `\ • ,\ -\ �`\ 1\ 11\\\ \\\\\ / // ' ' / / ` '\ / I ) ' j i 1\ \ �j , 1 5 �/�/� �l - -\-\ `C �O•`\\ \\ \'SN. �\ N. \\\ \ `\ `� \ `k \\ ��\ •�• N \\ I I t \ _� \\� \\. J ) ii' / _, \\ / \ v \ ` '.' / / , )II IIII I / ' /� •C - `\ A- \ \J \ `\ \ ` ` \ \ \\ ` \ \ \ \ \ ♦-, _ - ,% / �I�r� \ I I �- \ \ \ / / / / I IIIII / / f//, `- ---- r- G) -`\ 1� \ \ `\ \ `\ `\ \ \ ) � `\ \♦\ \ - _ - \ ` I 1 11. I- -%\ \ \ 11 II �/ /"\(�� \ i, \� . I __ _ INSET .— .`f-1 \`\ �`\\\\ \\ / j / / I�II'1 j I `\/I // / _-- -- ^ '\ `t/�2V \\\ ,,, q \\\ \` `\ \\ `\\\ \ %/L'-\ `,�%n■n \\� �\ `\d0 ♦� I l"\` 1 i;� �,j�I 1 \\ \`/ / / I /I 1 0I �_- l -----'- `- `\ N° \ \ \ I ' \\ \\ ,.\ \ \�_ --1 \ �, ``------- SCALE: 1 =30 \%% \\\ `\ \\ / / I I Il �I / __-/ -\ \\ \d20 \- \\ \\ \\ `\\ \ \ //��\ \\ \\ \\ \\ \ �� i.\\\\�- \ \ - \ \\\ , ---------f `- //i / - \ N. \ \ \ - 1 \ \ \ \ \ \ \ \ °1i \ l /' --- ------- -- ' `- __---- / / /",p1 / ♦. . __ J \ \ \ \ \ \ \ \\ \ -� - 30g / / / \ \ \`\ \\ ti` --�,-.: _-i>'/ l _- ( -1- _-__� ------ \\ \\ \ \ ` ` \ \ ` `\ \\ \ ` \ `\ \\ \oy \ 1 I ! '^ `\\3 O _ i / r,\ / \\ \ \ \ \ \41�1 O \ / '�1\ \\\�\ i \ \ r-� ( -� \ \ \ `\ \\ \\\ \ ` \\\ ` ` \ `\ \ � `�` ��M a\ I / . / 299--- i \ \ \ \ \ \ \ \ \ \ . �/ v, , / ^\ \ l 4, \ \ \ \ \ \ \ \ \ \ \ • • - \ / \ \\l \ N \ \ \ 1 1 I \\ \ \ --\ `\ \\ ` \ \ \ \ \ \ \ \ ♦ ` -N. v 0 / /'// 1 \ v / 1 All \ /Al k \ \ \` �- / \\ / I. \ \ \\ \ \ \ \\ +\- \ \ • ,i • - \ _ \ {�'� I CI,` /, , / \ \ \ \ \ \ \ \ \ \ \ _ \ \ / / �` -\l�\�,�`/AII` \` `\ `iA��(l'� \\ \\ \-_ , /� />' / ( \ \ \ \ \ \ \ \ \ \ \ \ 1+ 1 - \ c --moi •, /// )��1\ IIL�//),I��\ \\\ \\ \�i \ `�\` `\ -- -"' ''' ,,-------------\ ------- /^_-----Y------ 1� / I 1 J--`-> \ \ \ \\ \ \ \ \\ \\ ` --\ \�\ •\ •\ \\ \` ' ♦\ i \\ \``\ \ /� 1 • �r„� ♦� i �/ / \ \ \ \ \ \ !• • / < `\\ \ \ �^IIll \ \ �/ \ \-- _ \ `\ r / -,"I \`\ \\ \` \`\ \ \ \) \ \ \ ` \\ \\ `\ ,% \ `\ \ \ `\ \\ \\\ `\\ `\ `\ `\I \\ \ \\ _ /\\\\ ���� �♦ ' II,\L\ \\ \ \/ II \ \ \ / ///,k \ � --- �, \ , \ \ \ l \ \ N. \ \ \ \\ \ `\ -\ \ \ \ `\ `\ / `I /^ - - \��� F•'1 / �•�•-w■■ ■1�) 1\`;\I`tea' \�� //�`\ `\ `\�--- ///��---- - \\ \\\ `\ \l I I I \\ \\ \ \ \\ \ -`\ - �\ `\\ \ \ \ \ \ l / I /�'\ ,/\\ ♦:l•- . � /)/ 1 1 �`�l, II` el 7 `\ \`-\ ) ' I I \ `\ UR�ENS CREEK ` 1 I ; ' ��--- = ' I - ' I ' I ' I ) S `TRIBUTARY 4 I J )) 00, \, \ \- J / \ \ \ I 1 ///, ,� //,11, r� fr?le -- L% ( \ `\ \ \\ \�- -' 2 � - �i/ /' ' 1 / 1 ' / / \ \\ � \ `\\ \ `\\ \\ 1\ \\ \ 1 � \\ I of � i 4J // /, / nll 1 �� // / \ ` // // / jll l 1 I I I I i' 1�'v' 7 \ \ \ \\ \ ______-- J � 0 = / % / . \ ' \ \ \ \ \ I 1 , \ r„ 1 ., / / II 1 I I I \///+ � \ \ \ / / / / / \ 1 /^ I l I /^/” / \` \ ` _ '/ \ \ Lam\ \\ `,`\ -- r// I ` \ a I I I \ I \� / l 1 / // // /Ill\ 1 I I I V� ��/ \\ , \ \ \__^-__...- - �{��- -! �� � � ��� � �i - � ' / / / / , , ` \ -\ ---� \ \I `-, ,n1 19 I I ' \ \ \ \� 00- ,//,' // I 1 I 1 1 �,, %'\/i \ \\ \\ \\ 1 �� ' i i i i i \\ \- r \ ` \I I i i I \\ 11 { / / , lA I1. // fKr \ \ ,_- _ �(UI) ,-___ -\ --- --\ \ \ , ( / / / / , / / \ ^\ , MI l I I \ \ I I \ ti{ \, / , /// / I J I IIL \ - _ \ / / -/ I \ I I � ,\ 11 /_= ,e I l r // / f 3 / 1 `\ / / / / rrr �r - y1�1 \ \ I MI MI / 11 r-- v I \ \ . / )11 �`_- .l\\\ \ \ - \ \- \ / / \/ \ I l I I 1 I \ \ Ili// r-�/(`\\ \ 1 1 \ \ `- ,/' / / / )11 �L__ '" J/ \ / ��\ \ \ \\ - \ \ I I 1 / / I / 1' '' ,- ,`\ _ 1 ////,Ill ( \ \ 1 1 \ .. / , / / / -_, 1 -- , , �� - -\ \ \ `\� \ \--`_ \\ 1 ( ; / %' / / 1 I I I I I ' I 1 11 1 �_ _ /---------- '� _= i - / I --� 111 i1 \\ `\ \ \dam` \\ \ \ \\\ \\ \\ //� / / / / / \\ �('\IL_ "�^_ = J /( \\\ r --A7, >i\\ \ \\ \ \\ - ��-- 1\ \`_ i \ 1 1 1 / i i ' ' --- % / I l \ , '- ` �_! _� __-_= =_=_________� _ ______________=__-=='__===� �-� -__ _=====z --- - L � � i' I __--//I 11 L\ \ \ \ \ \ I \ \ \ \ \ \ / / / ( 1 1 1 1 \ 1 1 ./,4i/ 1 ` \ `� - `� \- \- / \ I / / / / / / / ,� -- - -- - \ n. - s - 1 Il N. W. \ \ \ \ / / / \��-_-- II \t-�/»jIl \\ \ �`.^ �-- _ ` NOW -OR 'FORMERLY: / /, _--_-- _� \\ �___ _ �---\ - \ `\- --- \ \-\ --- - � ' V -- - o&-- \ L - " / l `\ \ ` \\ `fill\ \ \ \ `\1 - / 1 I I 1\\ �,� , ( \ \ \ �1 _-_ -I. - ARE -NC REGION NO 14 LL /' \ - - \`\ ' - --- ` \ - -� ' I I I I \ \ice / `%w� \\ / \ \ --/x-%, ` \.. ----`__--- -\ o r (/ / /-- --��-- -� /I I -- - \ --- y� - �Q' - - I -- / %\ 1 \ ` ` \ 1� l \\ �\ `� / / I I T�-; ; / r t \ J;/� 1 \,; - PI 0748-03-02-7196 I / _-- - -----' +� \__ \ -\l /~ V - _ - i • \ l `\`\ \ J / // / \ / 1 -�- -d/ --� \ �� \ \\ �Il �� \\\- \ -` --_ / % I �r J I� 1 N `7//� '� �I \ \ \\ \\ \` -_- Ccs/�I \ �� `` , ", \ / #• I I --`�- ---- / b', `\ \ A( -S - _ ,�l ' -- --- \ \ \ \ \ l \ \ `__-- _/ r I I ( \ 1� -�_ -�- \ ' I ( -�_`-- - ^� *jrlJa-- ` - c - '- - ` --�\� \ _--_-�_'J ' I r i 11 / \ \ ��-__ I '•'` ` -� --- `\ - ----- -- ---- - -- ' / -\ \\ - -,(OF --- / _ �'R w \-- \ \\ �= - vll L9( IIC� %�/n I l \l I 1 I l \ \ ` �1 -%\ ✓�-\- _ PARCEL ID#: 157816 I I r ' -1 - \ \ \ \ I 1 , / /j/, 1 , l \ \ � �/ - \\ - -�- / \ \ - �2� ,g - - r- \ m `\ \\\\�_-`�� - \ \\\;\ --_ _--- M /'/ /j' \��1 \ \ \ \ ` \\ \\ /// l_�� L�,�"I\\ - �-� - \` \` 42.38 ACRES I I I (�"����__--�-- -- 1 �,/ \I �\ `C p� ` ` �_— ; `\` �` \ -- _- _--- / //,, /' ` 1 \ \1) \ \ - //) 1 \__ //" 1 "I �_-;`\\ \ DB: 6902 PG: 392 i I - -\ -- / --- iQ ` \ \ _� , / I \ ` 1 \ \ \ \ \ A11�J \ \ 1 I / �` \\\\ \ �\\�- -- - _-J ///,l. (�1 11111 \ \ \ \ \ \ `\ /' J\\\r`'i ���t, r7�_- _ �^ \�- - _i'' I I I / \\ `\ L- -!::� \ - ---`---- . \ ` "�� --- /, / I IIIII \ \ \ \ \ ,// /)\\ \^l\�'AiI( ��lL ---- �� L�ti�'``� \ ZONED: RSCH it I I I I / �- t \\( `\`-_ '' r-,_ 1 C� } ---- \\\ C9 �� "� i i 4/ �` - _ __-_------;%������1'� - I I I ill \ \ \ \ - ./ / / n _ J / 7� < \ \\ U,SE: OFFICE I \ %' _ 1 I Y-' > - r - ' �V \ _ _ �'•- �"'. \-- �--- - Ilv �.-liiii; ----\--\�\\ \�` -� _ _-- ��_" )\\\11 \ ��\\\ \\\\\ \ \ 1\\ \\ \\- ,� �/ i ji �/l�"`-�- _=> 1\ `\ \\ \\\`\ \\ ---- ,� ) I I 11 I I I I \ I 1 1 / /r--``' \/1�\I)/ I ,, -_ / / �I, l / �y f Yvv �i��� �- �������� �� ` iT-�-`�� \�� `��- 7-- -J i\\I\\ .:.0 \ \\\ \`\\ `�77�, ` \\\ \` /' j /� / ll�'l` - J�ll \`\ \\\\ \\\ \; \--\ �,� 1 / l I I I i \ II 1 1 ( , /-----� ������ 1 \`\- `---' � > -` / t�' ; ' ,) !) i ( gs / / l.^ l / 1 I / r--- I /� / _ - - - \ `� > / �V}! !� ,`\��/� \ ?'- 1 :`ire !� Q ��` ------_�--_- \�\\\ -� - -___�. / /�\\ \\ \ \\ ,.,\ , ' /z/ \ \ \ \ \ / / I I I I j 1 1 I //' �� \ c \ _a / / _J V - `� ---- ,- / / / \\ \\\\��..\�l !!� // �.4 �% _/,/ \\\ \\\ \ `\ `, \� \\- I / I I ' I I ' I / / / / (�- L//'LLL�f 1 \ \ - - ' /i -'�-\\-�`-- - \ ' ' / /h\ \`\\ I \ \ \ '/ i /j-%�JIr I -//rl\ \\ \ \\ \ \ \\ \ \\ ` - -__J J I I I I 1 ( I l l 1 ' )\ C-\ / C /` \\ \ / i' I \l! J�`\ - ! _a // 0,,.� \- _- __ _ ` -- / •�•••�(.'11 , \\\ I1 \ \ \ / / /, /n^\J i1�, - _J,1'I\ \ \ \ \ \ \ \ \ \ , / I I 1 1 1 \ 1 I I l 1 ' 1 \ \\/,t� /� \ \ `\ / ---------� �- Y� - i- `-� = // \ LSI) p�l)))1 \ \ \ \\ - --., / / �<�/ Jf�i/" \/, \ �- J/`\\ \'\\ \\ \ \\\\\\ \\ \\ \-1 ---\---_----.j / l J l l l `\ ` I `\ / I ' l ' � \ -( i \ \ `\ \ ��' �' `\ = - j -- __ _-- /i/ �. .l 1\ Zl \\<C �� \ \ \ \ - / / l \C �1� \����_J�\ \\ \\ \ \ \ \ \- - ��-- /i / / > ) I 1 ' I \C\\\.� \ \ \ \ \ _,-----------\------ /11 I -"\ tea- 11 _ \ h -\l llt \ \ \\ \\� " \\ \\ I--- ' J / / l ' �\ / , ) �-�\\' - 'i ��\\\\ \\ \ \ \ \ \ -- \ -- - -/' / / ' ' . / / J� 1 / I -*\\\" \\ \\ \ ---' J / I a ♦/ ' ♦ 0 \\\ \\ \ / )1 \ \ - \ \ / , I 1 / / l \ , f fry , ���` -\\\\\ ` \� \ \ \\ / I I 1\\\ ` \\ `% -- ` --- / / / / / I , 1 .\ \\ \\ \ \ \ `-�-- r• `1 �\ / - / '� / SII - \ ` \ \\\,\ \�\ _�' / ! ,' ' � J J' 1) ` \ I. / � / / 1 1 / ( / gin\ ) I \ \ \ /,/ - / : a s .~ J 0 -� - �J -\�� �\\ `\`� \ \,,', / / ) I I ( '> /", ((/( i , L \\ \ \ `\ \ \\ --------- -- �/' / ' / i / / ) ' I 1 I / l / 111 l \ l\\ \ \ `�-� "l' / �\\`,\c-- ��Z�\ % / ---,, --I______ _�''' �- lye r \ \ `_ \` \\\ , \ -' / / / ) Ili r � I \ 1 \ \ \ , `\ \\ \ -- - _ / / / / I I I I ( ( II \\ \ \\ \ / /\^1 I\ ,f \ \ / / //'"`-- , ', �� _ / \ *„ � N.- IN \` \��\\ \\ --/ / / / ) I I I \ I \ I \ I \\ \ \ \\ \\ \\ N, ---- .- , / / / / ' I I I \\ \ \ / /Il f\�� // / , \` / � �v ! \ _ / \ ,- / / I I \ \ \ \.. \ ..� \ \ / / / I i \ \` \; \\`\ \` \\ \ \ \ \\ --�----------- J / // 1 ( I I I \\ \\ --�/'/ - , C�ij/,/rL�\\l - / r-- " \ t4iir 1 \ \ ;4� \_--- / /�/ I I \/\\\\\\ \ \ � `., \\\ ` \---_-_ - ' / / � \\\, ` Gln '' -t-_.., %` �( / 1 ' I I \\ \ ,5- f r "I 4. D 10, i-�r--_� // % / ((\ \\ ` \ -� \\ l\--( ` �\ ``- --�/ ' ' I 1 I I (� / \ -�� �` - .iF � S� 1 /( I I I I \I 1 1 \ �,� ` \ `\\\ / j '.i��' ---Alb- --\ / I \ r (1 I �\ 1 \ L/ \ - / J / I \ �- -- �� I 1 \ `\\ - -J j�L\l I i I `\\�` 1 l / l 1 i - i \ ` ` - - '/ // I\\ :� -, 1 T \ / / I \ \ \--� - N,- \ - I I - 1 \I \ I / / % / /,\ \\ \ I \ - -- /,� 1 I I/ 1 BI�RBENS-eREE1f--------- // l I 1 I I `\ ) O \ ✓' /---717,1111i 1 1 I / \ `--------_-`__ I I \ \ - _-\ \ l 1 \ 1 / / \ \ 1 / \ ``� __ I\ I l -------- /EFF.ECTIVE' F I I I -- ��ti 1 I / / l / \ I I <-- / d` N.\,\ \ " \ � - ��''�--,I\ _� J�` ?/r %%%% / / / l \\-------- __------ _ FL00 LAIN ' I ; I \` - \ ����� l 1 �\ `_� ; / / \� 1 1 \ _ -` I \\ III I ' / < < ----- ------__--- ' / i 1 `\------- -1 v� \ \ \ \ \ ,/ ' ( / ,,,'^\\ \ `\ \` i \ i / _ I 1 \ \ \ - \ , �I\ll \ \ \ \`\\\\ \`_ --� // \ /J�l\~- // / ( I I I 11 I 1 ) r -- \ I , 1 l , \ \ \ `\ /' / / � , (' j " \ \ \ I 1 ' \ \ tel. \ ' -- /` V 1 / 1 1 1 1 / - \ `- / / / \ / \ / �i • R` \ _ -� - - ten\ //, \ \- - , / I I I _ \ \ / 1 I i D / 's '~ - ) \ \ �\ ` �li� --- __Jj\L4"„ll \ / i i 1 I I 1 \ ; / --\ N.\i /I\ \ \ \ \ / , . , / / / ^ I / / 1 y.� \ -- _ i --- \\ 'c \ () I I I I I 1 1 ( / \ \ \ \ ` \ \ `\ `\ /' ,, / / / / / 1 I 1 1 \ ( Z / I I C \ \ \ \ \ \ / / 41 I I \ \ - a=-=_.- - / . - ��R l,\W, 1 I I I l I II 1 \ \ I \ % , r--- \ \`\ `\ \ `\ ___.' /' / / % / /i111 1 1 1 j ) I ' , l`� O i/ / \_` \ : -�\- �' i -, -- FORMER J) 1 1 i i 1 \\ \ \\ \\ \\ \ \\\\ \ i I f i I \\ `\\ \ I\\\\ \ \ \\\ \ --- / // , / % ' ( `\\� \ \\ \ \\ ` `! / H TRIANGLE FOUNDATION � ` - `"� -=�f --i I \ \ I Ire \ \ \ 1 \ \ ` \ \ \ � f \ `\` \,,II \\� J/(��� `� \ \ \ I \ 1 \ \ \ \ \ \ 1 1 I I \ \\ � \ \ \ \ \ / / I I \\ \ \ \ \ \ OF 0 ROLINA \ `— i \ � \\-- \\�\\\\\` I \\\ \� I NI - \ I ` \\ `\ ` I 1 I i \\\ ` ` `: \. \ --- % / / 1 I \\ \\ \ \ \ \ \ l I \ - / PIN 0738-04- -6521 / I ,N \ \ ` - \���� ��`�\\` `\- ' --\--- - - ,.- I, i \\ \ `\ i I 1 1 1 I I i i i / \\\\ \ \ \ -\,\ ` - / / / / i I )i ` I\ - ` \ 1 \ `\ `- - \ `��\1z\`\- \, N, - \ - \ \ \ 1 1 I 1 1 I 1 I \ \ \ \ \ \\ \ I \ / / % / /,/Ill'', 1 1 O , #: 574- 1-011 / % �► - -- \\\\\\ - _ I 1 1 1 1 I \ \ \ ,I--', / / / / / 'I I 1 \ 1 ) I 55. 1 ACRES 1\ \ ` `\\ ,--� �- � ��- \ \\ i 11 i I I 1 I I I \\\ \ \\ I\ \ \\ / //+1 1 1 1 ` ) ( \ \ / IU\ \ n \ \ - \\,- \��. -----\ ----> j ' 1 1 I I ,•I \ \ \\ \ \ ` . , / / / / (l ( \ 1 1 \ \ ZONE RSCH \\ \\ \ -- I/ I \ \ \ \ \zz __-_�: `----- -> ) )) I I 1 1 1 1 \ 1 ` \ \ \ \ \ \ / / / / / I \ 1 I, \ 1 I ( \ \ n / \ ` \I`------- \`\,, ��� `__/. ,, t IN-- _...\ \ _ J ''/ 1� / l , l j I i I I I I (' \ 11 \ \\ \ \ \ \ ` � / / / J A\)\ I l 1 1 I \ \ \ UU E• BORATO RE EARCH / Q \ \ -, x ,� �--- , / 1 1 if I 1 \ \ \ \ \ 1 \ "I , , / I\Y \ I \ 1 ` I ojif, /J) I I / I ) / A \ % \ \ \ll \ - I. , 11 - \\ �� \`- , � - --- '/ ' / ' / / / / / / \ \ \ \ 1 1 1 ` / /' / / / / '1111 ` ) 1 N7 I / \- - - �-- �\\ \\ -� ------ -/ "I/ ,�� / / / // / /j \\\ \\ I 1 \ 111\ \ \ \ -� / '� i / / /II 1 \ I� \ \ / Q ` -\ \ \\\ \\\ �_ �� -�� ------J / / // / / / I ` 1 I 1 I `\ \` `- -�_J // , / / ' / J11 I I I I I 1 \ \ \ _ 1 1 1 \ \ // I 1 / \ F111111 L- �// NOW OR FORMERLY: a ' — _ -. \ \ - -\\ - `----"�/I, \�\\�-- ' ` iiiiiiiiii \\-- - - --�/ / /,�'' \ \ i i I l 11 \ - ,/ \111 \` `\ RESEARCH TRIANGLE INSTITUTE \ \ ♦--- I- /// �� /._-_ `\�� �__----\\\ / - \ ) 111 �\\\ PIN#: 0748-03-02-2741 \ \ , o o \ — _ % /,//,/, --- - �1 I `� DB 393, PG 847 �.- / - 1 \ \ ` � PB 132, PG 124 \ \ O ----- J/(/ l C/ ` I' J _- \- \ \\ -\- v I I 1 l \\\\ a RCEL ID#: 574-01- 01 / Ilir� --i----- \`\\ ` \` 1 i 1 \ \ \ l 8.58 ACRES \ < -___-� `\- \ - -'I 1 \ \ \ ZONED: RSCC? — — \ ~`\\ I `\\ -, , -- -\ --� II 1 I.\\\\ 0 SE- RESEAR H / \ 4Q, - - I 1 \\ /\ \ IN \ .` / ----- ---------------14 -- r� - - —0 po�I ---/' - % /-^ �_ /' ,---, ` - \ \ \ T--1 O 111� *<,///,----- ` \ � \, `\� `\\lky VJJ I N __,\\ \\\ *��' -%%\\ \\� ^ �-) � CD ` \ -`--:: \ S2 \ \ `\ (��,\\ • ISI 0,-, I'll`\ ` \ \ I \` �i co Co \\\\ / `\ `\ \ % = Z -0 C\2 \ \ , ,, 1111 -,\ \I, \\\\\\%l WJ U) z I 1 / / \I I \ \ 1111111 = ,r-1 r. `\ •\• 1 `\ `\ `\ \%1,1\ W Q) \ • A, Y Q \ � \ I\11j11 O T \ Q) 4I / \\ \ 1 �./ 6 , q ` . -1 \ \ ) 1,1,\ T \ I--1 t],Q \\ 111 v �' \\ �f �1-1 � \`� �� �, ` \ _/ 11 111111 � Lo Nco 1 1 1 � � W \ /S /�� \\` ���,Q`-` \` �-� 11111 I--1 co ���\�\ ��������\ -" 111 V' \ \ \\ \\ \ �\\\\\\\ \ J 1 t W \ \ \\\\ \ .\\\\\\\---- I _ , r 1 '%� \\\\ \ \\\\\-�- ' I Vii' \\\\\\\\\ \\ \;\\ z J 11 10%%-1\ / \ N O 1%%% / % 1A"1111 %// �ppp // 0. �1! \ 1% I I .,�,. I -. I- -1 v- Qti Iw'f I 30 15 0 30 60 f :off � �/z \0-, w.z- �U:t1 u' M '�= SCALE 1"=30' '� '1-4 _� "Ill, ccI %t% uj 11 / N 3 W F MERLY: ONE RIVE LLC / w lbPIN#: - 3-00-9470 PARCE 44-01-00 Q 4 7 ACRES 0 E 01-2 FFI ' < go. I .wmw a a: �. Z op () M .J w 0 Irv: # x I J a 1: 0 �e t + l "', I .j < X cr i� s , w O w q< ' � U d"» o r It ,o 0 w Z ,,I �. I / ,zULLQ / Q40.11r, Q /cr O o� z I '" / I� 0 w (7 M wzQz ' v ,,----, � W < z U=) / >-� O I a: U wo 3: m a co0 a -a > Z 1: < a: o D NOW OR FORMERLY: D TRIANGLE SERVICE CENTER INC. PIN#: 0748-03-00-0624 PARCEL ID#: 544-01-002-50 16.58 ACRES ZONED: SC USE: COMMERCIAL DATE: 5-30-2019 REVISIONS: ' ,\ -\----% % �, `\ I , 100 50 0 100 200 \ \ 1-7 1 1 O �� \ 1 ` i / , / \ \%/ � 1 �-- /./ \ � � \ � a\- � � SCALE 1"=100' 11\ — PROJECT NAME: ARE -NC REGION NO 14, LLC DAVIS DRIVE ENTRANCE ROAD DWG NAME: SCALE: AS NOTED SHEET NO. Appendix 6 Pump -Around Detail PUMP ZONE 250' MAX DISCHARGE WITH ROCK STABLE OUTLET \ (NOTE 3) OR ON BEDROCK S q I� 1 DISCHARGE HOSE /INTAKE HOSE 7D ,♦FLOW SEDIMENT PUMP _ AS NEEDED— PECIAL STILLING BASIN DIVERSION PUMP WITH ROCK PAD RAW PUMP BASE FLOW NOTE: 1. WORK AREA TO BE STABILIZED AT THE END OF EACH WORK DAY. 2. ROCK SILT SCREENS REQUIRED FOR PUMP AROUND OPERATIONS ARE CONSIDERED INCIDENTAL TO PUMPING. 3. STABLE OUTLET TO CONSIST OF ROCK PLACED IN CHANNEL FOR ENERGY DISSIPATION AND 45' ELBOW INSTALLATION AT THE END OF THE PIPING SO THAT THE WATER DISCHARGES VERTICALLY UP IN THE AIR. THE OUTLET WILL BE APPROVED BY THE DESIGNER PRIOR TO PUMPING. TYPICAL PUMP AROUND OPERATION SCALE: NOT TO SCALE ARE -NC REGION NO 14, LLC DAVIS DRIVE ENTRANCE ROAD, RTP Saw TYPICAL PUMP AROUND OPERATION DURHAM COUNTY, NORTH CAROLINA DATE: MAR 31, 2015 WARD CONSULTING ENGINEERS, PC 4805 Green Road, Suite 100 919 870-0526 Raleigh, NC 27616 FAX 919 870-5359 Appendix C Environmental Documents ECS Carolinas, LLP Limited NEPA Database Review ESP Associates, P.A. Wetland Survey Map McKim & Creed Stormwater Management Plan Approval O - E IC S CAROLINAS, LLP `Setting the Standard for Service" Geotechnical - Construction Materials - Environmental - Facilities NC Rea,stered Engineenra Firm �:-1078 December 19, 2014 Mr. Jay Smith O'Brien/Atkins Associates, PA PO Box 12037 Research Triangle Park, North Carolina 27709 Reference: Limited NEPA Database Review Hamner Institute for Health Services 6 Davis Drive Durham, Durham County, North Carolina ECS Project No. 06:22070 Dear Mr. Smith, ECS Carolinas, LLP (ECS) is pleased to provide our results of the Limited National Environmental Policy Act (NEPA) Database Review conducted for the above -referenced site. Our services were provided in accordance with ECS Proposal No. 06-18137. BACKGROUND INFORMATION The site is located at 6 Davis Drive in Durham, Durham County, North Carolina (Figures 1 and 2). According to Durham County Online GIS Database, the site consists of two contiguous parcels that are identified as Parcel Identification Numbers (PINs) 0748-03-12-4785 (13.59 -acres) and 0748- 03-02-7196 (42.4 -acres). ECS understands that a portion of both parcels are to be evaluated (approximately 2 acres in size). The parent parcel is currently developed with Hamner Institute for Health Services and several additional structures. No structures were observed on-site. Other areas on the site consist of undeveloped, wooded land. Based on the United States Geological Survey (USGS) Topographic Map, two unnamed tributaries to Burdene Creek are located along the southeastern portion of the site. ECS was contracted to conduct a preliminary threatened and endangered species determination and a preliminary historic and archaeological resources review for the site. ECS personnel conducted the field reconnaissance on November 6, 2014. PRELIMINARY THREATENED AND ENDANGERED SPECIES DETERMINATION Congress passed the Endangered Species Act (ESA) in 1973. The purpose of the ESA is to protect and recover imperiled species and the ecosystems upon which they depend. It is administered by the U.S. Fish and Wildlife Service (USFWS) and the Commerce Department's National Marine Fisheries Service (NMFS). The USFWS has primary responsibility for terrestrial and freshwater organisms, while the responsibilities of NMFS are mainly marine wildlife. Under the ESA, species may be listed as either endangered or threatened. "Endangered" means a species is in danger of extinction throughout all or a significant portion of its range. "Threatened" means a species is likely to become endangered within the foreseeable future. All species of plants and animals, except pest insects, are eligible for listing as endangered or threatened. For the purposes of the ESA, Congress defined species to include subspecies, varieties, and, for vertebrates, distinct population segments. 9001 Glenwood Avenue, Raleigh; NC - 27617-7505 • T. 919-881-9910 F: 919-861-9911 - www.ecslimited.com = Capi[o6 Services, FLLC • EGS CaraGnas LLP • ECS [entry€, FLLC • ECS Flo ida, Li r7 •ECS Mid-Atlantrc i L' - F S Midwest L Lr E{ ,S Southeast, LLC • ECS Texas i-'_=' Limited NEPA Database Review Hamner Institute for Health Services 6 Davis Drive Durham, Durham County, North Carolina ECS Project No. 06:22070 ECS reviewed the USFWS Endangered Species Database to identify federally protected threatened and endangered species in Durham County, North Carolina. The following federally protected threatened and endangered species were identified in Durham County, North Carolina. Common Name Scientific Name Federal Status Record Status Vertebrate Bald Eagle Haliaeetus leucocephalus BGPA Current Vascular Plant Michaux's Sumac Rhus michauxii E Current Smooth Coneflower Echinacea laeivigata E Current BGPA= Bald Eagle Protection Act Species/Habitat Description Bald Eacllle E = Endangered Description: Distinguished by a white head and white tail feathers, Bald eagles are powerful, brown birds that may weigh up to 14 pounds and have a wingspan of up to 8 feet. Male eagles are smaller, weighing as much as 10 pounds and have a wingspan of 6 feet. Sometimes confused with Golden eagles, Bald eagles are mostly dark brown until they are four to five years old and acquire their characteristic coloring. Habitat: Bald eagles live near rivers, lakes, and marshes where they can find fish, their staple food. Bald eagles will also feed on waterfowl, turtles, rabbits, snakes, and other small animals and carrion. Bald eagles require a good food base, perching areas, and nesting sites. Their habitat includes estuaries, large lakes, reservoirs, rivers, and some seacoasts. In winter, the birds congregate near open water in tall trees for spotting prey and night roosts for sheltering. Conclusions: The approximate 2 -acre site consists of wooded land and three streams. The wooded areas consist of mature and immature hardwood and pine trees, approximately 20 to 50 years in age. Moderately dense understory is present throughout the wooded areas. Three streams are located on the southeastern portion of the site. The streams varied from approximately two to fifteen feet in width and one to ten feet in depth. The streams have well defined bed and banks, moderate to heavy baseflow, moderate sinuosity, and assorted substrates. Wetland areas are located adjacent and abutting the stream features located on the site. Large bodies of water and a steady food support base are not believed to be present on the site or in surrounding areas. Based on our knowledge and site observations, suitable habitat for the Bald eagle is not likely present on the site. Michaux's Sumac Description: Michaux's sumac is a rhizomatous, densely hairy shrub, with erect stems from one to three feet in height. The compound leaves contain evenly serrated, oblong to lanceolate, acuminate leaflets. Most plants are unisexual; however, more recent observations have Limited NEPA Database Review Hamner Institute for Health Services 6 Davis Drive Durham, Durham County, North Carolina ECS Project No. 06:22070 revealed plants with both male and female flowers on one plant. The flowers are small, borne in a terminal, erect, dense cluster, and colored greenish yellow to white. Flowering usually occurs from June to July; while the fruit, a red drupe, is produced through the months of August to October. Habitat: Michaux's sumac grows in sandy or rocky open woods in association with basic soils. Apparently, this plant survives best in areas where some form of disturbance has provided an open area. Several populations in North Carolina are located on highway right -of ways, roadsides, or on the edges of artificially maintained clearings. Other populations are in areas with periodic fires, and two populations exist on sites undergoing natural succession. One population is situated in a natural opening on the rim of a Carolina Bay. Conclusion: The approximate 2 -acre site consists of wooded land and three streams. The wooded areas consist of mature and immature hardwood and pine trees, approximately 20 to 50 years in age. Moderately dense understory is present throughout the wooded areas. No Carolina Bays or highway right-of-ways are located on-site. Roadsides and artificial clearings located on the parent property appear well maintained. Based on our knowledge and site observations, suitable habitat for the Michaux's sumac is not likely present on-site. Smooth Coneflower Description: Smooth coneflower is a perennial herb in the Aster family (Asteraceae) that grows up to 3.3 feet tall from a vertical root stock. The large elliptical to broadly lanceolate basal leaves may reach up to 8 inches in length and 3.0 inches in width and taper into long petioles toward the base. The leaves are smooth to slightly rough in texture. The stems are smooth with few leaves. The mid -stem leaves are smaller than the basal leaves and have shorter petioles. Flower heads are usually solitary. The rays of the flowers (petal -like structures) are light pink to purplish in color, usually drooping, and 2 to 3.2 inches long. Flowering occurs from late May through mid-July and fruits develop from late June to September. The fruiting structures often persist through the fall. Reproduction is accomplished both sexually (by seed) and asexually (by rhizome). Habitat: Smooth coneflower is typically found in open woods, glades, cedar barrens, roadsides, clearcuts, dry limestone bluffs, and power line right-of-ways, usually on magnesium- and calcium- rich soils associated with amphibolite, dolomite, or limestone (in Virginia), gabbro (in North Carolina and Virginia), diabase (in North Carolina and South Carolina), and marble (in South Carolina and Georgia). Smooth coneflower occurs in plant communities that have been described as xeric hardpan forests, diabase glades, or dolomite woodlands. Optimal sites are characterized by abundant sunlight and little competition in the herbaceous layer. Natural fires, as well as large herbivores, historically influenced the vegetation in this species' range. Many of the herbs associated with smooth coneflower are also sun -loving species that depend on periodic disturbances to reduce the shade and competition of woody plants. Conclusion: The approximate 2 -acre site consists of wooded land and three streams. The wooded areas consist of mature and immature hardwood and pine trees, approximately 20 to 50 years in age. A moderately dense understory and herbaceous layer are present throughout the wooded areas. Roadsides, artificial clearings, power line right-of-ways or clearcuts are not located on the site. Based on our knowledge and site observations, suitable habitat for the Smooth coneflower is not likely present on the site. Limited NEPA Database Review Hamner Institute for Health Services 6 Davis Drive Durham, Durham County, North Carolina ECS Project No. 06:22070 Other federally listed threatened and endangered species have not been identified in Durham County by the USFWS. Based on our assessment of the on-site conditions, ECS did not identify federally threatened or endangered species or their habitat on the subject site. PRELIMINARY HISTORIC AND ARCHAEOLOGICAL RESOURCES REVIEW The State Historic Preservation Office (SHPO) was created by the United States government in 1966 under Section 101 of the National Historic Preservation Act (NHPA). The purposes of SHPO include surveying and recognizing historic properties, reviewing nominations for properties to be included in the National Register of Historic Places, reviewing undertakings for the impact on the properties, and supporting federal organizations, state and local governments, and the private sector. ECS was contracted to conduct a preliminary historic and archaeological resources review. The scope of work included a field reconnaissance to identify potential historic structures, a review of aerial photographs, and a review of the SHPO Online GIS mapping. The site reconnaissance was conducted by ECS on November 6, 2014. The site is currently located in a commercial area of Durham, Durham County, North Carolina. Areas surrounding the site are developed with commercial buildings. Other areas consist of undeveloped, wooded land. ECS reviewed aerial photographs of the site and immediately surrounding properties for evidence of past development. The aerial photographs were obtained from Durham County GIS and are dated 1994, 1999, 2005, and 2010. Aerial photographs dated prior to 1994 were not available for review. The ECS review is dependent on the quality and scale of the photographs. In the 1994 aerial photograph, the site appears wooded. It appears that the Hamner Institute for Health Services and associated structures are located on the parent parcel. The adjacent properties located to the northeast, southeast, and southwest appear to be developed with commercial properties. In the 1999 aerial photograph, the site appears consistent with the previous 1994 aerial photograph. Significant changes were not noted in the vicinity of the site. In the 2005 aerial photograph, the site appears consistent with the previous 1999 aerial photograph. It appears that the previous commercial building is no longer present on the southern adjacent property. Other significant changes were not noted in the vicinity of the site. In the 2010 aerial photograph, the site appears consistent with the previous 2005 aerial photograph. It appears that a commercial building and associated parking lot have been developed on the southern adjacent property. Other significant changes were not noted in the vicinity of the site. ECS reviewed the SHPO Online GIS Database (http://gisncdcr.gov/hpoweb/). As depicted on Figure 3, no recorded historical sites are located on the subject site. Several recorded sites are depicted within 1,500 feet of the site. Those sites are identified as: (DH — USDAF Forest Service Limited NEPA Database Review Hamner Institute for Health Services 6 Davis Drive Durham, Durham County, North Carolina ECS Project No. 06:22070 Southern Research Station, DH2533 — Research Triangle Park, DH3502 — Main Laboratory Building, DH3503- Head House, DH3504 — Annex, and DH3505 — Old Chemical Storage. The GIS database did not identify other Indian religious sits, historic structures, or historic places on the site. Based on our site visit, the review of historical aerial photographs, and the online SHPO GIS database, ECS did not identify significant architectural or archaeological resources on the subject site. AGENCY CORRESPONDENCE ECS composed letter requests addressed to the North Carolina Natural Heritage Program (NHP), the USFWS, and the SHPO dated November 11, 2014, to determine if the subject site is located in the immediate vicinity of registered sightings, habitats for endangered species, or near significant architectural or archaeological resources. ECS received a response from Ms. Allison Schwarz Weakley, Conservation Planner, with the NHP on December 2, 2014, which states that the NHP does not have records of rare species, important natural communities, significant natural heritage areas (SNHAs), or conservation/managed lands within the proposed project area. However, the letter states that Douglass's Bittercress (Cardamine douglassii) is located approximately one mile south of the proposed project area. The letter states that the Douglass's Bittercress is located in the vicinity of Northeast Creek floodplain, above Grandale Drive. Additionally, the NHP database shows that the Stirrup Iron Creek Marsh and Sloughs natural area are located approximately 0.6 miles east of the site. A copy of this correspondence is attached. ECS received a response from Mr. John Ellis for Mr. Pete Benjamin, Field Supervisor, with USFWS on December 12, 2014. The letter states that based on the information provided, and other information available, it appears that the project as currently proposed will not impact federally listed species or their habitats. Therefore, they believe that the requirements under Section 7(a)(2) of the Act are fulfilled. A copy of this correspondence is attached. ECS received a response from Ms. Renee Gledhill -Earley, SHPO Representative, issued on November 24, 2014 for the site. Based on the information submitted, SHPO is not aware of historic resources which would be affected by the project. A copy of this correspondence is attached. CONCLUSIONS ECS has conducted a preliminary threatened and endangered species determination and a preliminary historic and archaeological resources review for the site. Please note that our services did not include detailed studies for threatened and endangered species or historic and archaeological resources. However, based on our observations and knowledge of the site, the database review, and correspondence from representatives of the NHP, USFWS and the SHPO, it is our opinion that the project will not adversely affect federally protected threatened and endangered species or historic or archaeological resources. Additional assessment is not recommended. Limited NEPA Database Review Hamner Institute for Health Services 6 Davis Drive Durham, Durham County, North Carolina ECS Project No. 06:22070 In order to protect aquatic resources, vegetated buffers should be maintained around water bodies on the site and on the downstream side of the project. In addition, best management practices for erosion and sedimentation control should be followed during construction activities. CLOSING ECS appreciate the opportunity to provide our services to you. Please contact us at (919) 861- 9910 if you have questions or require additional information. Sincerely, ECS Carolinas, LLP 111�&W-4 1 - Cory Darnell Environmental Project Manager Ryan Conchilla, PWS Environmental Project Manager Attachments: Figure 1 — Site Location Map Figure 2 — Aerial Site Map Figure 3 — SHPO Map Agency Correspondence Historic Aerials Photographs co;� C. Brian Smith P.G. Principal Geologist LEGEND ~ �� Approximate Location of Site Boundary SOURCE: FIGURE 2 AERIAL SITE MAP Durham County GIS Hamner Institute for Health Science 2012 Aerial Photograph and 6 Davis Drive ECS Field Notes Durham, Durham County, NC Not to Scale' ECS Project 06: 22070 H Id A r CH 31 Buildong N -10 40 h .1 rn n R — t Rc- so IWO LEGEND W A LEGEND c �j 0 Approximate Location of Site Boundary Approximate Location SOURCE: FIGURE 3 OURCE: SHPO MAP OU C Historic r s r t io Office State Historic Preservation Office Hamner Institute for Health Science c P 0 IS Online GIS 6 Davis Drive Cq Durham, Durham County, NC I I ECS Proiect 06: 22070 MA�MP AI NCDENR North Carolina Department of Environment and Natural Resources Office of Land and Water Stewardship Pat McCrory Bryan Gossage John E. Skvarla, III Governor Director Secretary December 2, 2014 Mr. Cory Darnell ECS Carolinas, LLP 9001 Glenwood Avenue Raleigh, North Carolina 27617 cdarnell(@ecslimited.com RE: Hamner Institute for Health Services 6 Davis Drive, Durham, Durham County, North Carolina ECS Project No. 06-22070 Dear Mr. Darnell: Thank you for the opportunity to provide information from the North Carolina Natural Heritage Program (NCNHP) database for the proposed project referenced above. The NCNHP database does not show any records for rare species, important natural communities, natural areas, or conservation/managed areas within the proposed project area based on the maps submitted with your request for information. Within one mile of the proposed project area, the NCNHP database shows an element occurrence record for the following rare species: * For status definitions, please see the Definitions document at http://www.ncnhp.org/web/nhp/database-search. The occurrence record for Douglass's Bittercress is located southwest of the proposed project area, in the vicinity of Northeast Creek floodplain above Grandale Drive. In addition, the NCNHP database shows that the Stirrup Iron Creek Marsh and Sloughs natural area is located ca. 0.6 miles east of the project area. This natural area contains high-quality examples of Piedmont/Mountain Semi -Permanent Impoundment (Shrub and Piedmont Marsh Subtypes) and Mesic Mixed Hardwood Forest (Piedmont Subtype) natural communities. Please note that although the NCNHP database may not show records for rare species within the proposed project area, it does not necessarily mean that they are not present; it may simply mean that the area has not been surveyed. Occurrences of rare species documented within one mile of the proposed project area increase the likelihood that these species may be present within the project area if suitable habitat exists. The use of Natural Heritage Program data should not be substituted for actual field surveys if needed, particularly if the project area contains suitable habitat for rare species. 1601 Mail Service Center, Raleigh, North Carolina 27699-1601 Phone: 919-707-86001 Internet: www.ncdenr.gov An Equal Opportunity 1 Affirmative Action Employer- 50% Recycled 1 10% Post Consumer Paper ELEMENT OCCURRENCE STATE FEDERAL SCIENTIFIC NAME COMMON NAME STATUS* ACCURACY STATUS* STATUS* Cordamine douglassii Douglass's Bittercress Current Low T --- * For status definitions, please see the Definitions document at http://www.ncnhp.org/web/nhp/database-search. The occurrence record for Douglass's Bittercress is located southwest of the proposed project area, in the vicinity of Northeast Creek floodplain above Grandale Drive. In addition, the NCNHP database shows that the Stirrup Iron Creek Marsh and Sloughs natural area is located ca. 0.6 miles east of the project area. This natural area contains high-quality examples of Piedmont/Mountain Semi -Permanent Impoundment (Shrub and Piedmont Marsh Subtypes) and Mesic Mixed Hardwood Forest (Piedmont Subtype) natural communities. Please note that although the NCNHP database may not show records for rare species within the proposed project area, it does not necessarily mean that they are not present; it may simply mean that the area has not been surveyed. Occurrences of rare species documented within one mile of the proposed project area increase the likelihood that these species may be present within the project area if suitable habitat exists. The use of Natural Heritage Program data should not be substituted for actual field surveys if needed, particularly if the project area contains suitable habitat for rare species. 1601 Mail Service Center, Raleigh, North Carolina 27699-1601 Phone: 919-707-86001 Internet: www.ncdenr.gov An Equal Opportunity 1 Affirmative Action Employer- 50% Recycled 1 10% Post Consumer Paper Hamner Institute for Health Services 6 Davis Drive, Durham, Durham County, North Carolina ECS Project No. 06-22070 December 2, 2014 Page 2 Feel free to contact me at 919-707-8629 or Allison.Weaklev@ncdenr.gov if you have questions or need additional information. Sincerely, Allison Schwarz Weakley, Conservation Planner NC Natural Heritage Program United States Department of the Interior Cory Darnell ECS Carolinas LLP 9001 Glenwood Avenue Raleigh, NC 27617 FISH AND WILDLIFE SERVICE Raleigh ES Field Office Post Office Box 33726 Raleigh, North Carolina 27636-3726 December 12, 2014 Re: Hamner institute for Health services- Durham County, NC Dear Mr. Darnell: This letter is to inform you that a list of all federally -protected endangered and threatened species with known occurrences in North Carolina is now available on the U.S. Fish and Wildlife Service's (Service) web page at http://xvww.fws gov/raleigh. Therefore, if you have projects that occur within the Raleigh Field Office's area of responsibility (see attached county list), you no longer need to contact the Raleigh Field Office for a list of federally -protected species. Our web page contains a complete and frequently updated list of all endangered and threatened species protected by the provisions of the Endangered Species Act of 1973, as amended (l 6 U.S.C. 1531 et seq.)(Act), and a list of federal species of concern' that are known to occur in each county in North Carolina. Section 7 of the Act requires that all federal agencies (or their designated non-federal representative), in consultation with the Service, insure that any action federally authorized, funded, or carried out by such agencies is not likely to jeopardize the continued existence of any federally -listed endangered or threatened species. A biological assessment or evaluation may be prepared to fulf ll that requiremep_t and in determining whether additional consultation with the Service is necessary. In addition to the federally -protected species list, information on the species' life histories and habitats and information on completing a biological assessment or evaluation and can be found on our web page at http://www.fws.gov/raleigh. Please check the web site often for updated information or changes. ' The term "federal species of concern" refers to those species which the Service believes might be in need of concentrated conservation actions. Federal species of concern receive no legal protection and then designation does not necessarily imply that the species will eventually be proposed for listing as a federally endangered of threatened species. However, %%e recommend that all practicable measures be taken to avoid or minimize adverse impact, to federal species of concern. If your project contains suitable habitat for any of the federally -listed species known to be present within the county where your project occurs, the proposed action has the potential to adversely affect those species. As such, we recommend that surveys be conducted to determine the species' presence or absence within the project area. The use of North Carolina Natural Heritage program data should not be substituted for actual field surveys. If you determine that the proposed action may affect (i.e., likely to adversely affect or not likely to adversely affect) a federally -protected species, you should notify this office with your determination, the results of your surveys, survey methodologies, and an analysis of the effects of the action on listed species, including consideration of direct, indirect, and cumulative effects, before conducting any activities that might affect the species. If you determine that the proposed action will have no effect (i.e., no beneficial or adverse, direct or indirect effect) on federally listed species, then you are not required to contact our office for concurrence (unless an Environmental Impact Statement is prepared). However, you should maintain a complete record of the assessment, including steps leading to your determination of effect, the qualified personnel conducting the assessment, habitat conditions, site photographs, and any other related articles. With regard to the above -referenced project, we offer the following remarks. Our comments are submitted pursuant to, and in accordance with, provisions of the Endangered Species Act. Based on the information provided and other information available, it appears that the proposed action is not likely to adversely affect any federally -listed endangered or threatened species, their formally designated critical habitat, or species currently proposed for listing under the Act at these sites. We believe that the requirements of section 7(a)(2) of the Act have been satisfied for your project. Please remember that obligations under section 7 consultation must be reconsidered if: (1) new information reveals impacts of this identified action that may affect listed species or critical habitat in a manner not previously considered; (2) this action is subsequently modified in a manner that was not considered in this review; or, (3) a new species is listed or critical habitat determined that may be affected by the identified action. However, the Service is concerned about the potential impacts the proposed action might have on aquatic species. Aquatic resources are highly susceptible to sedimentation. Therefore. we recommend that all practicable measures be taken to avoid adverse impacts to aquatic species, including implementing directional boring methods and stringent sediment and erosion control measures. An erosion and sedimentation control plan should be submitted to and approved by the North Carolina Division of Land Resources, Land Quality Section prior to construction. Erosion and sedimentation controls should be installed and maintained between the construction site and any nearby down -gradient surface waters. In addition, we recommend maintaining natural, vegetated buffers on all streams and creeks adjacent to the project site. The North Carolina Wildlife Resources Commission has developed a Guidance Memorandum (a copy can be found on our website at (http://www.fws.gov/raleigh) to address and mitigate secondary and cumulative impacts to aquatic and terrestrial wildlife resources and water quality. We recommend that you consider this document in the development of your projects and in completing an initiation package for consultation (if necessary). 2 We hope you find our web page useful and informative and that following the process described above will reduce the time required, and eliminate the need, for general correspondence for species' lists. If you have any questions or comments, please contact John Ellis of this office at (919) 856-4520 ext. 26. Sincerely, to Benjamin Field Supervisor 3 List of Counties in the Service's Raleigh Field Office Area of Responsibility Alamance Beaufort Bertie Bladen Brunswick Camden Carteret Caswell Chatham Chowan Columbus Craven Cumberland Currituck Dare Duplin Durham Edgecombe Franklin Gates Granville Greene Guilford Halifax Harnett Hertford Hoke Hyde Johnston Jones Lee Lenoir Martin Montgomery Moore Nash New Hanover Northampton Onslow Orange Pamlico Pasquotank Pender 4 Perquimans Person Pitt Randolph Richmond Robeson Rockingham Sampson Scotland Tyrrell Vance Wake Warren Washington Wayne Wilson btu. STATE,, North Carolina Department of Cultural Resources State Historic Preservation Office Ramona M. Bartos, Administrator Governor Pat McCrory Secretary Susan Kluttz November 24, 2014 Cory Darnell ECS Carolinas, LLP 9001 Glenwood Avenue Raleigh, NC 27617-7505 Re: Hamner Institute for Health Services, 6 Davis Drive, Durham, ECS 06-22070, Durham County, ER 14-2541 Dear Mr. Darnell: Thank you for your letter of November 11, 2014, concerning the above project. Office of Archives and History Deputy Secretary Kevin Cherry We have conducted a review of the project and are aware of no historic resources which would be affected by the project. Therefore, we have no comment on the project as proposed. The above comments are made pursuant to Section 106 of the National Historic Preservation Act and the Advisory Council on Historic Preservation's Regulations for Compliance with Section 106 codified at 36 CFR Part 800. Thank you for your cooperation and consideration. If you have questions concerning the above comment, contact Renee Gledhill -Earley, environmental review coordinator, at 919-807-6579 or environmental.review cgncdcr.gov. In all future communication concerning this project, please cite the above referenced tracking number. Sincerely, (�_� ` —QJAAA �OKRamona M. Bartos Location: 109 East Jones Street, Raleigh NC 27601 Mailing Address: 4617 Mail Service Center, Raleigh NC 27699-4617 Telephone/Fax: (919) 807-6570/807-6599 ,fi V 1 -}r LEGENDIN Approximate Location of Site Boundary SOURCE: 1994 Aerial Photograph Durham County, NCE(!Q Hamner Institute for Health Services Online GIS Database 6 Davis Drive Durham, Durham County, NC Not to Scale CPI I ECS Project No. 06: 22070 ' `` r J r • tip' l•�; i� �, �i7r A i 1jo L - y Ott IV LEGEND Approximate Location of Site Boundary '�► �'� .; SOURCE: — 2005 Aerial Photograph Durham County, NC AWL Hamner Institute for Health Services Online GIS Databasero 7% wo 6 Davis Drive _ Durham, Durham County, NC Not to Scale ECS Project No. 06: 22070 Hamner Institute for Health Services — Limited NEPA Database Review 6 Davis Drive Durham, Durham County, North Carolina ECS Project No. 06:22070 Photo 1: View of the northern portion of the site, facing south. Photo 2: View of the wooded land on the site, facing west. ECS Carolinas, LLP Page 1 r:Ok �P y i t Photo 2: View of the wooded land on the site, facing west. ECS Carolinas, LLP Page 1 Hamner Institute for Health Services — Limited NEPA Database Review 6 Davis Drive Durham, Durham County, North Carolina ECS Project No. 06:22070 Photo 3: View of the main stream that transects the site, facing south. Photo 4: View of the stream located on the eastern portion of the site, facing southwest. ECS Carolinas, LLP Page 2 ESP Associates, P.A. Wetland Survey Map I, AUGUSTIN D. KEANE, PROFESSIONAL LAND SURVEYOR HEREBY CERTIFY THAT THIS SECTION OF WETLAND SURVEY WAS MADE UNDER MY DIRECT SUPERVISION AND THAT IT IS CORRECT TO THE BEST OF MY KNOWLEDGE, AND BELIEF; THAT THIS WETLANDS SURVEY WAS MADE IN ACCORDANCE WITH NCBELS WETLANDS MAPPING POLICY BP 1005-4 REV. 1; AND THAT THIS MAP MEETS THE REQUIREMENTS OF THE STANDARDS OF PRACTICE FOR LAND SURVEYING IN NORTH CAROLINA (21 NCAC 56.1600) 1I , A Z N.C. PROFESSIONAL LAND SURVEYOR L-4474 "This certifies that this copy of this plat accurately depicts the boundary of the jurisdiction of Section 404 of the Clean Water Act as determined by the undersigned on this date. Unless there is a change in the law or our published regulations, the determination of Section 404 jurisdiction may be relied upon for a period not to exceed five (5) years from this date The undersigned completed this determination utilizing the appropriate Regional Supplement to the 1987 U.S. Army Corps of Engineers Wetlands Delineation Manual." Regulatory Official: Title: Date: USACE Action ID No.: I, Augustin D. Keane, certify that this map was drawn under my supervision from an actual GPS survey made under my supervision and the following information was used to perform the survey: 1. Class of Survey: Class A 2. Positional Accuracy: 0.10' 3. Type of GPS Field Procedure: NCGS VRS Network 4. Dates of Survey: January 1, 2014 5. Datum/Epoch: NAD 83 (NSRS 2011) 6. Published/Fixed-control use: See Plat 7. Geoid Model: Geoid 12A 8. Combined Grid Factor: See Plat 9. Units: US Survey Feet PPOJFCT 130UNPMY ♦� N/F ,,**ARE -NC REGION NO. 1 DURHAM COUNTY P 0748-03-12-478 DB 6902 PG 392-3 PB 11 PG 362-36 592,300 SF ♦13.60 ACRES COMPUTFI7 POINT 17 ANNUAL CHANCE -- F00PHNF 1 I Floodplain Boundary lines shown were provided by the I ARE -NC REGION NO. 14 LLC North Carolina Floodplain Mappinq program, 1 DURHAM COUNTY PIN All floodplain boundary lines are effective May 2, I 0748-03-02-7196 / DB 6902 PG 392-396 2006 and reflect boundaries Shown on PFIpM I PB 11 PG 362-365 3720074800J, I 1,857,024 SF Horizontal Patum for floodplain NAP 83, I 42.63 ACRES Vertical Patum for floodplain NAVP 88, j MTLANI75 i OIJNPARY / ACk�5 - 0021 / APFA - 115 12 5Q FT. / / COMPUTE MW ppOJ�C1130UNbA1?Y an rr THIS WETLANDS SURVEY SUPERCEDES THE SURVEYS OF THE SAME NAME DATED 1/8/15,1/16/15, AND 1/22/15, SCM ♦ h SEALED BY AUGUSTIN D KEANE, PLS �0 W 000\AQ1 0,9 FXI511NCI CONCkFTF MONUMENT r / �INFAP `XfA61� Of 5TPFAM PPOM COMPUTED POINT AW8FT 5P-1 TO COMM19 POINT - I59,12' O ... EXISTING IRON PIPE Point Table NOW OR FORMERLY Point # Northing Easting Description 90001 782236.19 2041749.26 SD -1 TTCULVERT START 90002 782210.27 2041725.73 SD -2 AW7FT 90003 782180.88 2041701.41 SD -3 AW8FT 90004 782175.27 2041701.24 WD -1 TT SD 90005 782164.25 2041696.60 WD -2 90007 782159.70 2041688.46 WD -3 TT SD 90008 782162.17 2041685.54 COMPUTED POINT 90006 782132.57 2041660.42 SD -4 AW10FT 94 782115.48 2041645.63 SD -4 AW8FT O ... EXISTING IRON PIPE NIT... NOW OR FORMERLY DO ...COMPUTED POINT C3 ...SD FLAGGING • ...WD FLAGGING 60" RCP 1 % ANNUAL CHANCE FLOODLINE ------ FLOODWAY ■ ...EXIST. CONIC. MONUMENT ■ PROJECT BOUNDARY - - - - RW LINE - - - TIE LINE I ft 04 4 5LLC I 15 I �"r♦ �s 6 NIP N: 782290 22 / F:2041-75869/ n IO compuj�n polNr / 580°15' 51 W 67�7� 1 , TIS To QIP i ,Ai 59' Soh' 2611W F 2041 749 26 / I i SD -1 TT CULVE4 START AW8 17 Line # Direction Length SD -2 AW7FT j C3 L2 S 39'36'12" W 38.15 L3 N 40°18'53" E j/ / L4 S 40'18'53" W SD -3 AW8FT v S 1'44'53" W � WD -1 TTj SDI S 22°49'56" W 11.96 POINT v WD S 60°50'26" W 9.33 LLJI Y� 3.82 L9 22.60 Ow= i A ((OF J Q D-4 ! Q -' 0 co ,� ♦ 1 I I Ni 18213251 F: 2041660,42 1 I I I I I I I � 1 GRAPHIC SCALE 0 25 50 100 1 INCH = 50 FEET Line Table Line # Direction Length L1 S 42°13'11" W 35.01 L2 S 39'36'12" W 38.15 L3 N 40°18'53" E 24.53 L4 S 40'18'53" W 38.83 L5 S 1'44'53" W 5.61 L6 S 22°49'56" W 11.96 L7 S 60°50'26" W 9.33 L8 N 49°41'07" W 3.82 L9 S 40°52'56" W 22.60 SURVEYED BY: WETLANDS LOCATION SURVEY: PREPARED FOR: EN.P.B scALE: ESP Associates, P.A. 5 1" = 50' E Sp 5121 KINGDOM WAY O'BRIENIATKINS ASSOCIATES PA CHECKED BY RALEIGH NC276W ARE -NC REGION No. 14, LLC p K.D.M ON - PHONE 919.678.1070 6 DAVIS DRIVE 5001 S. MIAMI BLVD. -0ESCRIPTIS Knx slss77.Izsz WETLANDS SURVEY RESEARCH TRIANGLE PARK, NC 27501 DURHAM, NC 27703 SHEET WWW ESPASSOCI ATES.CONI DURHAM COUNTY, NORTH CAROLINA IJCF:N4: NO Cs0587 DURHAM COUNTY, NORTH CAROLINA 1 OF 1 McKim & Creed Stormwater Management Plan Approval DURHAM Engineering and Environmental Services December 5, 2014 Oliver Sherrill ARE — NC Region No. 14, LLC 7020 Kit Creek Road Suite 100 Research Triangle Park, NC 27709 Re: Stormwater Collection Systems Plan Approval 6 Davis Drive — Hamner Institutes DRB Number D1400055 Durham County Stormwater Project #SW -140$ Dear Mr. Sherrill: On October 27, 2014, we received a stormwater construction drawing package submittal package for the 6 Davis Drive project located at 6 Davis Dr, Durham, NC. This construction drawing set is approved by this office on December 3, 2014. Enclosed is a copy of the plans and calculations, stamped approved by this office. The approved stormwater collection system consists of: 1. Installation of a wet detention facility with a design permanent pool volume of 13,589 CF. 2. Installation of bio -retention facility with a design volume of 7,603 CF. 3. Installation of a bio -retention facility with a design volume of 1,92$ CF. 4. Installation of a bio -retention facility with a design volume of 6,165 CF. Our office will issue a Stormwater Operation and Maintenance Pen -nit for the stormwater control measures after the following are completed: 1. The Stormwater system is constructed and final construction inspected by a registered professional engineer, a registered land surveyor, or a registered landscape architect. A signed and sealed copy of the inspection report must be submitted to this office. 2. The final As -Built Plans sealed and signed by a registered professional engineer, a registered land surveyor, or a registered landscape architect must be submitted. 3. An operation and maintenance plan sealed and signed by a registered professional engineer, a registered land surveyor, or a registered landscape architect must be submitted. 4. An operation and maintenance agreement signed and notarized by the property owner. This will be drafted near the end of the project. 5. An improvement security must be provided to our office in accordance with Ordinance Section 14-155(e). Our calculations indicate a performance bond in the amount of $56,106.64 is necessary to ensure construction, and continuing operation, maintenance and inspection of the facilities. Performance bond forms and information can be found on the Durham County Engineering / S&E Webpage. If you believe this bond amount is incorrect please contact me. See Attached. Please feel free to contact me if you have any questions pertaining to this approval at (919) 560-7992. Sincerely, Ryan D. Eaves Stormwater Manager cc: Curtis M. Blazier, PE McKim & Creed, INC BMP Performance Bond Calculations BMP: Vliet Detention Pond Performance Bond Calculations Project Name: 6 Davis Dr - Hamner Facility Name Wet Detention 1 Bio -Retention 3 Bio -Retention 3A Bio -Retention 4 Facility Drainage Area AC 5.10 3.08 0.77 2.77 Facility Volume CF 39,220 7,603 1,928 6,165 Capital Costs' ($) $ 30,382.75 $ 9,635.21 $ 3,687.62 $ 8_,320.03 $ - $ - O&M Costs 2 {$) $ 1,215.31 $ 385.41 $ 147.50 $ 332.80 $ - $ - Inspection Costs ($) $ 500.00 $ 500.00 $ 500.00 $ 500.00 $ - $ - Total ($) $ 32,098.06 $ 10,520.62 $ 4,335.13 $ 9,152.83 $ - $ - Total Bond Date Notes: $ 56,106.64 121502014 93:54 1) Capital Costs = 18.5 * Volume 2) O&M Costs = 4% Capital Costs 3) Inspection Costs = By Durham County Source: NCDENR Stormwater BMP Manual