HomeMy WebLinkAboutWQ0040882_Application (FTSE)_20190405Y
State of North Carolina
Department of Environmental Quality
DWR Division or Water Resources
ISA NCAC 02T .0300 — FAST TRACK SI.WI?R SYSTEM EXTENSION APPLICATION
Division of Water Resources 1•" 1'A 04-16 & SUPPORTING DOCUMENTATION
Application Number: W 0 4 t:o beconiptened by [MRt
All items must he Completed or the u licaliun will be returned
I. APPLICANT INFORMATION:
I Applicant's name: Town of FuiLay-y:irimi (con npany, municipality, HOA, utilily, etc.)
2. Applicant type; ❑ Individual ❑ Coihoralion ❑ General Partnership
❑ Federal ❑ SlaWICounty ® Municipal
3 Signature authority's name: ?ay Meyers. Pli per ISA NCAC 021' dlltldtlll
Title; Public Utilities Direclor
4, Applicant's mailing address: 401 Oki Huaey,cttll hand
City: Fut u-Vurina State: NC Zip; 27526-�
5. Applicant's contact information:
Phone number: (2L9) 567-3911 Email Addius.; jnk_y •r� r4F`fJuay.v;iriuu,itire
❑ Privately -Owned Public Utility
❑ Other
WC Dept ofEnviromental Quality
APR - 5 2019
Raleigh Regional Office
11. PROJECT INFORMATION:
l . Project name. Meg Tme SuNlivisiun - Phase 2 & 1
2. Application/Project status ® Proposed (Ncw Permit) ❑ Existing Perntit/Projcct
It' a modification, pmvide the existing permit numtcr: WQ00 and issued date:
If ocw conslruc6011 hul Parl Ufa inaster plat, providr the existing permit number. WQO) _
3. County where project is located: Wake
4. Approximate Coordinates (Decimal Degrees): Latitude- 35.5,728 Longitude: -78 9247E
5. Parcel ID (irapplicable). 065621396�
(or Parcel ID to closest downstream sewer)
III. CONSULTANT INFORMATION:
I. Protessiunal Enghieer: JercinX NI. Keepy, 13H.KS I,icenic Number 039739
Firm: McKim & Creed. Inc
Mailing address. 17,10 Varsily I)Hvg
City: Raleigh State: NC Zip- _27( _
Phouc number. (�)19) Q.1.8091 F..nnail Address: jkccnylr+Fltki:inlCfetlL101n
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
I. Facility Nan c: North Hanle R • iuil 11 nil1will I�id I it y Permit Number: NC0021636
Owner Namc: Hantetl County
V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF):
1. Pennit Number(s): WQ00_ 3630,3 Downstream (Receiving) Sewer Size: H inch
Sy' —will Wide L:oIlvoitin Sxslyni Veriiiii a 111er x ' "a 1 llir:nhle WQCS00193
Owner Narne(s): Town oi'1=untwX-V1lriou
FORM: F1'A 04- 16
Pitgc 1 01'5
V1. GENERAL REQUIREMENTS
1, If the Applicant is a Privately -Owned Public Utility, has a Certificate o[' Puhlic Convenience and Necessky been attached?
❑ Yes ❑No [ NIA
2. 1r ll:c Applicant is a Developer of lots to be sold, has a I •v •lo a 'x 0iignitinvial Agryinnelo f'O i I• )FV I been attached'?
❑ Yes ❑No ®NIA
1. Irthe Applicant is a Hon •/ t:e QW ss jnu. hats an 01wralional Aercenx:nt tF( 10W, I10A)been attached?
❑ Yes ❑No ®NIA
4. Origin of wastewater_ (check all that apply);
® Residential Owned ❑ Retail lstoms, centers, malls) ❑ Car Wash
❑ Residential l.cased ❑ Retail with rood prepuration/se rvice ❑ Hotel and/or Motels
❑ School / preschool 1 clay cart: ❑ Medicai 1 dental I veterinary facilities ❑ Swimming Pool /Clubhouse
❑ Food and drink Facilities ❑ Church ❑ Swimming Pool/Filter Backwash
❑ Businesses I offices I factories ❑ Nursing Horne ❑ Otter (Explain in Altaclnnenl)
5. Nature nr wastewater : 100 df,: Dnmcstic/C:omrncrcial f7r Cornmci'ciul
'.: Industrial (Sec 11A NCAC 02'I' .i)10] 20
b,Is lhert a Pretreatrnent Program H effect? ❑ Yes ❑ No
6. Has a flow reduction been approved under 15A NCAC 02T .01 f4 I'? 0 Yes ❑ No
L If es ruvide n eo t • of lluw reductiou a m-ril letter
7. Summarize wastewater generated by project:
Establishment Type (sec 021.01140
Drily Design Flow •
No, of units
Flow
Residential
300 galldary
128
38,400 GPD
gall
C;PD
call
GPD
bale
GPD
ga11
GPD
g;�I1
GPD
Toral
38,400 GPD
a See IJLs NCAC02"1' .t)114),h).,(d), fe)(I? and fe)(2) rot caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access Facilities located near high public use
areas; and residential property located snulh nr Calf of [tic Atlantic Intracoasta. Waterway to be used as vacation rentals
as defined in G.S. 42A4),
b Per 15A NCAC 02T .01 14(c), design flow rates ror cstahhshmcnts not identified (in table 15A NCAC 02*1',01141 shall
be determined using available flow data, water urine I imures, occupancy or operation pallcrns, and other measured data
8. Wastewater generated by project: 38,400 GPI) .per I A NCAC 02T .011.1)
> Do not include future flows or previously perin:tted allOLL-60ns
If permitted nowis zero, indicate wlty_
❑ Pump Station or Gravity Sewer where flow will he per mined in s0seq_ent perrr:us Taal connect to this line
❑ Flow has already been Acicaled in Permit Number.
❑ Rehabilitation or replr,cerrrew of existing sewer with no ilea flow expected
❑ Other (Explain):
FORK 1 f A 04-1 b Page 2 of 5
VI1. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.0305 & ;NIDC (Cravity Sewers):
f, Summarize gravity sewer to he permitted:
Size (incites) Length (feet) Material
B 4,793 PVC
EEE I I
�+ Section If & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
Section III contains information related to minimum slopes for gravity sewer(s)
Y Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T.0305 & MDC IPunun Slations/Force r�luiusl:
COMPLETE FOR EACH PUMP STATION INCLUDIM I THIS PRO EC`l*
J Pump station ntEmber or name:
2. Approximate Cnordinates (Decimal Degrees): Latilude: Longitude: -
3. Design flow of the pump station: millions gallons per day (firth capacity)
4- Opernuonal puirrt(s) of the primp(.): gallons per minute at feet total dynamic bead (TDH)
5, Summarize the force main to he permitted (for this Pump Station).
I Size(Inches) I Length (feet) I MniLrial I
6. Power reliability in amordance with I iA NCACO2T.030,50of1 :
❑ Standby power source or pump with automatic activalion and tclernefry - 15A NCAC 02T .0305(h)(I)(13):
'v Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
T- Must he permanent to facility
Or if the pump station has an average daily flow less than 15.1100 gallons per day:
❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCACO2T
.0305(h)(1)(C)
nr
❑ Portable purnping unit will; plugged emergency pump connection and telemetry - 15A NCAC 12T .0305(h)(1)(C)'
y It shall he dernonstrated to the Division that the portable s❑trrce is owned or contracted by the applicant (draft agreement)
and is compatible with the station,
Y If the portable power source or purnp is dedicated to multiple pump stations, an evaluation of all the pump siatituts,
storage capacities and the rotation schedule of the purtahle power source or pump, including travel timerrttmes, shall he
provided in the case of a multiple station power ouuree.
FORM: IFTA 04-16
Page : of 5
IX. SETBACKS & SEPARATIONS — (02B .11200 & 15A NCAC 02T ,0305(t)):
I, Does the project comply with all separations found in I M NCAC 02'1' .11311.51 f) & tL"l ® Yes ❑ No
Y 1.5A NCAC 021'.0305(1) contains minimum sc iaratimis that shall be nrovidcd fur sewers Clettl5'
Setback Parameter*
Separation RC aired
Storm sewers and other utilities not listed below (vertical)
24 inches
Water mains (vcrtical•waterover sewer including in henched trenches)
IS inches
Water mains horizontal
10 Bret
Reclaimed water lines vertical - reclaimed over sewer)
IS inches
Reclaimed water lines (horizon(al - reclaimed over sewer)
2 feet
**Any private Or public water supply source, including any wells, WS-I waters nr Class I Or
Class IT impounded reservoirs used as a source of drinking water
100 feet
**Waters classified WS (except WS-I or WS-V), 13, SA, ORW, HQW, or SB from normal
high water (or lids elevation) and wetlands sec item 1X.2)
50 feet
**Any other stm'a~am, lake, impoundment, or ground water lowering and surface drainage
ditches
10 feet
Any building foundation
5 feet
Any basement
10 feet
Top sloe of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and n]lercC tordrains
5 feet
Anymimming pools
10 feel
Final earth grade (vertical)
36 inches
Y I5A NCAC 02T. 3oS , contains alternatives whine separations in t12'I',030(flfl cunnot be achieved,
Y "*Stream classifications can be identified using the Division's +Lt(' Surl'srcr li'utcr(rlassiliralions �ecE�a�c
If noncompliance with 02'1'A.105(ft orine).sce Section X of this application
2. Does the project comply with scpvration requirements tin wetlands? (50 feel of scparelron) 0 Yes ❑ No ❑ NIA
See the Division's drn►ft separation requirements for sinn]tio]ns where separation cannot he meet
Y No variance is required if the alternative design] criteria specified is utilized in design and construction
Y As built documents should mlerence the 'ocadon of arens ctfccwd
3. Does the project comply with setbacks found in the river hasin rules per ISA NCAC 0211.112mr! ® Yes ❑ No ❑ NIA
�, This would inchrde Trout Suffcrcd Streams per 15A NCAC 213,0202
4, Does the project requnc coverage/at.lhorizatinn under a 404 Nut ton wide or ❑ Yes ® No
individuate permits or 401 Water Quality Cerufrcations?
►' Information can he obtained from the 401 & Buffer Permilling Branch
5. Does project comply with IM NCAC OYC',01115 c fi (additional permits/certifications)'? ❑ Yes ❑ No
Per I M N9AC 02T.11 116MI61, directly related environmental permits or cerl1icaliun applications are being prepared, have
been applied for, or have been ohlained, Issuance of this permit is contingent ou issuance of dependent permits (erosion and
sedimentation control plans, stormwater management plans, etc.).
6. Dues this project include any sewer collection lines Out are deemed " high•priorily?"
Per 15A NCAC C 02T.(M0 "high priority sewer" means "any aerial sewer, sewer conlaeting surface waters, siphon, or sewer
positioned parallel to streamhanks thott is suhlccl to erosion that undermines or deteriorates the sewer.
❑ Yes ® No ❑ NIA
10 If yes, include an altaclunent with details for each line, including type (aerial line, size, malerial, and location)
High priority lines shall be inspected by the permittee or its representutive at least once every six -months and
Inspections documented per ISA NCAC 021'.0403(a)(5) or the permitee's individual System -Wide Cullectian permit.
IC'ORM. i--I'A 04-16 Page 4 of 5
X. CERTIFICATIONS:
Does the submitted system comply with 15A NCAC 021 the Minimum nccicn Criteria fnr ilic Permitting of Pump Stations
mill hill-Ce Nhtin: tlalesl versio tl, and the Cl rvi Sy fiver lit ituum Desi 'u Criteria (latest vc . inn as applicable'! -
0 Yes ❑ No
If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting dcxuments
lirr review, A.0ortivtd of the rcuucsl is recudred prior w submitted ni_Ihe mist Track APOIcallou and sunnorline
documents.
2. Professional Engineer's Certificuoun:
is
>'E PLS
from Application hens III. I )
dim this application for
has been reviewed by me and is accurate, complete and consistent with the information supplied in the: plans, specifications,
engineering Calculations, and all other supporting doCt11nenlali0i1 to the best of my knowledge. i further attest that to the hest
of my knowledge the proposal design has been prepared in accordance with the applicable regulations, Gravity Sewer
Minimum Design Criteria for Gravity Sewers (latest r. is;cn;, and Elie ,Minimum Design Criteria for the Fast -Track
Permitling of Pump Stations and Force Mains (latest version) Although other profcss;unals may have developed certain
Portions of this submittal package, inclusion of these matcr-als under my signature and seal signifies that I have reviewed this
material and have judged it to be consistent with the proposed design
NOTE — In accordance with General Statutes 143-215,6A and 143-215,6B, any person who knowingly makes any Calm:
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000,,is well as civil penalties up to $25,000 per violation.
North Carolina Professional Engineer's seal, signature, and date:
3. Applicant's Certification per 15A NCAC 02T -0106ff th): ) II
:1a 7Mt� • �• t/�l Ti.! 1 P.GTo%� anCSI Thai this application for
(Sign alurr At horhy's n mC & title from Application Item L3.)
has been reviewed by me and is accurate and complete In the bcsl of my knowledge. I understand that if all required parts of
this application are not compicied and that if all required supporting documentation and allachrncnts are not mtluded, this
application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -
discharge system to surface waters or the land will result in (in immediate enforcement action that may include civil penalties,
injunctive relief. and/or criminal prosecution. I will make no claim against [lie Division of Water Resources should a
condition of this permit he violated. I also rnderstand Ihat Wall required parts orthis application package are not completed
and that if ull required supporting :nformation and allachrnenls are not include([, this application package will he relurncd tc
me as incompletc.
NOTE — In accordance with General Stal(Ecs 143-215.6A and 1-13-215,611, anp person who knowingly makes any false
statement, representathtn, or certification in tiny application package shall he guilty of it Claus 2 miulcrncanor, which may
include a fine riot to exceed $10.000 as well as civil pcnaltic:a up to S25,000 per vim:k ion.
Signal
„ate.
FORM FI'A 04 16 Page 5 01' .5
i
OF WAT�q State of North Carolina
Department of Environment and Natural Resources
r Division of Water Quality
O -~c Flow Tracking/Acceptance for Sewer Extension Permit Applications
(FTSE 06-13)
Project Applicant Name. Town of Fuquay-Varina
Project Name for which flow is being requested: Bent Tree Phases 2 and 3
More than one FTSE may be required fir a single project i f the owner of the• WWTP is not responsible for all piunp
stations along the route of the proposed wastewater flow
1. Complete this section only if you are the owner of the wastewater treatment plant.
a_ WWTP Facility Name: North Harnett Regional WWTP
b. WWTP Facility Permit #: NC0021636
All flows are in MGD
c.
WWTP facility's permitted (low
2.60
d.
Estimated obligated flow not yet tributary to the WWTP
0.501
e.
WWTP facility's actual avg. flow
1.327
f.
Total flow for this specific request
0.038
g.
Total actual and obligated flows to the facility
1.866
h.
Percent of permitted flow used
71.8%
11. Complete this section for each pump .station you are responsible for along the route of this
proposed wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A)
(B)
(C) (D)—(B+C)
(E)=(A-D)
Design
Oh' :igated,
Pump Average Daily
Approx.
Not Yet Total Current
Station Firm Flow**
Current Avg.
Tributary Flow Plus
(Name or Capacity,* (Firm { pl),
Daily Flow,
Daily Flow, Obligated
Available
Number) MGD MGD
MGD
MGD Flow
Capacity***
Southern
, -1— 1.263 0.505
0.219
0.150 0.369
0.136
* The Firm Capacity of any pump station is defined as the maximum pumped flow that
can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking
factor (pi) not less than 2.5.
*** A .Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the WWTP where the Available Capacity is < 0.
Page I of-6
FTSE 06-13
Certification Statement:
I ray T. Meyers, PE, Public Utilities certify to the best of my knowledge that the addition of
Director
the volume of wastewater to be permitted in this project has been evaluated along the route to the
receiving wastewater treatment facility and that the flow from this project is not anticipated to
cause any capacity related sanitary sewer overflows or overburden any downstream pump station
en route to the receiving treatment plant under normal circumstances, given the implementation
of the planned improvements identified in the planning assessment where applicable. This
analysis has been performed in accordance with local established policies and procedures using
the best available data. This certification applies to those items listed above in Sections I and 11
plus all attached planning assessment addendums for which I am the responsible party.
Signature of this form indicates acceptance of this wastewater flow.
S
r
Date
Page 2 of 6
t=TSE 06-13
State of North Carolina
Department of Environmental Qualit%
Division of Water Resources
I-'Io"- Trackinf,lAcceptance for Smer Extension Applications
(FTSE 04-16)
Entity Requesting Allocation: I'm%in of Fuquay Varina
Project Name for which flow is being requested: Bent Tree Phase 2 and 3
ltorr than or it, ME Pit, it he rrytrirc iIIfit a .single projet 1 it thr rn, trrr i,j the tI 117P is mw r,., 1ToPrvi[1(v J.+r all pump
%twimis alrtutg the rustic ul'therlie I%fe'nurrr jTnu
I. Complete this section only if you are the o�tiner of the waste%%Mer treatment plant.
a. WWTP Facility Name: North Harnett Regional WWTP
b_ "-WTP Facility hermit ;�: NCO021636
t It flmv.s are in ;II GD
c. %V%VTP facility's permilted 11m%
7.5 NIGD
Fuquav-Varina allocated Flory
2.60 1,,1(,D
Liliinatott Allocated Flow
1.20 %vIGD
Angier Allocated Flocs'
1.008 NIGD
d_ Estimated obligated Ilow not yet IributaryF to the ww'TP
1.070 NIGD
FV Oblivated Flory NYT
0-501 NIGD
l.illington Obligated Flow NYT
0.11') MGD
HC Obligated Flow NYT
0.266 ,MGD
Angier Obligated Flow NYT
0.190 NIGD
C. WWII, facility's actual avu. 110%%
�
5.471 NIGD
FV Actual Flo«
1,470 VtGD
Lillinuton Actual Flow
0.923 MGD
I IC Actual Flow
2.387 MGD
Angier .Actual Flow
0,691 N-IGD
F. Total flow for this specific request
g. Total actual and obligated flexes to the facility
FV actual :rya. + Obligatcd Flo"
Llllington Actual AN g. + Obligated Floe
HC Actual .Avu. + Obligated Floe
Angier Actual- Obligated Flo«
h. Percent of pertnitied tlrny used
0.038 i11GD
6.579 MGD
1.030 NIGD
2,653 1NIGD
0,881 NIGD
87.72 %
Paue I of-4
t"I'sI {i(,-I
H. Comp let c tilt, section tier each ptunl? station %ou are re.,ponsil,te Ei1r itIong the rnl.11c of thu
proposed tkaste; %ater t1mv.
List putnp stations located
bcmecn the pro]ect contlection point and the WWIT
()
(11)
(C)
tn)=IIZ+c l tl.l-t.�-u1
Pully
A%cti _mac I)a:1..
Approx.
Nol Yel
I o1,al C urrca,
�r�riull f inn
Fh,a . *
C urrem ,�'.;.
rrit man
I log k 111u.
ttiameor CaFarn}. *
(Firm 111).
Doak I Lt,k.
ILill% FI m
r)hls_:1tcd A%,Jlh1WQ
tiu111hCrl MOD
\l(dt)
\IGU
Mt 1.)
1 lo"k C',qm lt. "
LS 120 14.4 5.76 2.809 0,917 ;,.'irlh 1
The firm Capacity of any pump station is defined as the maximmm pumped flo„ that
can he achieved %%ith the Iarue,sl punip taken out of ser%ice.
** Design A%eraoe hail► Flo%% is the firm capacitn of the pump station dkided b.N a peaking
factor (pl) not less [halt 3.5.
* "° A Phinninr Assessment Addendum shall be attached for each pump station located
hchseen the project connection point and the NN NVIT ►►here the A%ailable Capacity is < II.
Dokkwtrcam Futility Name: (So er); \ortli Ilarnett Rey,, -.anal W WIT
Do«nstrcam Permit Dumber, \C0021616 ---
III. Certification Stato:ment.
I Sieve Ward certik to the hest of iv knim ledge that the addition of
the voluille of wastewater to he pernimcd in thk project liaS been eValuated along the route to the
receivillO wastewater treatment tactlity and that the 11m% from this project is not anticipated to
cause atly wpacity related sanitary SO%cr m erflo«s or overburden any downmi-earl pump Station
en route to [lie receiving treatment plant under normal circumstances. Ul%ell the ilnp1e111CllldtiO11 O
the planned Improvements idcntilicd in the plammng, asScs lllellt «here applicahle. This artaksis
has been perlonned in accordance %%ith local established policies and procedurc,; u�ing the he.t
available data, This certification applies to those 11cir15 Il>ted UhONC in Section: I and 11 plus Al
attached planning assessment addcnd/tl lls for which I am the responsihle part. Sitiilaturr �11• this
lilnrl indicates acceptance of•this tszls�t uatcr tlo%%
.Sl�lifll�' (1lliritr! S'rkfrrrrirrrc° 1}(lie,'
Vagc 2 of 4
�.�. • f�7 err• �� f' 4
�Clyli � � i 1 'r 8'M� • - r '1ti
IN
_. � ��� v. � � vw "4� � j v� �.� '�� r � b� :r�l � 'i r iti }��l •Zr'��- w•�
�t i * e .Z. # + �,ti •� d R1. i�-.�} i :i�f f 4� 1, '� •i i. �� `, q
� �f� T�..��''_�+•'.+s ii� �`.t�''�#• ��_3y�t��k�]41� � ����t {�'�,1�`���Lar^' �� � r :�`-�•
�i
4 mat
74
.t J��M�� •�i--► *�r � �.J.. ,�� �, Sri t• Yam'. ,g'\ �
AIL
�..:d * �"rli 1+'r`'`i-. � ;^�� :¢� �` .�� �', r ,i?'r• t��•� `�'' �� .i: �L ram'
qg
IY1 1� �ti�F[—ti ,�. Lr.'� T 1�1i i�*t'9r) � `[�
z`y1i # �4Y�°:y :l bnil tda •r~;t`�•ty ~ d¢�' tl. b�l �+ fi r {i titer; `{
Fir
tat's
w u: t
Yr
10
`r#fir � � 'rL • # + �[ �e'T.�
OF
F
VW{
ro
•„�,� � � ice:: .ti�'�� _
4r
z 3'
�ilf r 1
Bent Tree Subdivision — Phase 1
USGS Map
` •uK4 % y f�. � war
.M1S y k�rOd
LOCATIMIL
5 %4853VOt1151,:U-Perm,I1PH1 Sanitary Sewer . DWR fast TraOdOwumemsNUSGS Mao doc.
ut"LL W L I VA till L ill U1111i1
Department of Environment
and Natural Resources
Division of Water Quality
Michael F. Easley, Governor
William G. Ross Jr., Secretary
Gregory J. Thorpe, Ph.D., Acting Director
November 7, 2001
Mr. Michael A. Allwav, Assistant Town Manager
Town of Fuquay-Varina r
401 Old Honeycutt Road
Fuquay-Varina, North Carolina 27526
Dear Ivtr. Allwav:
NCDENR
NORTH CAROUNA DEPARTMENT OF
ENVIRONMENT AND NATURAL RESOURCES
, Y10 0 8 22001
U= of puway-vew
Subject; Town of Fuquay-Varina
Flow Reduction Approval
Wake County
On September 10. 2001. the Division of Water Quality Non Discharge Permitting Unit received your
flow reduction request for future and present. but not yet tributary, single-family dwellings in the Town of
Fuquay-Varina. The letter requests approval of a residential flow value of 220 GPD/residence for these
dwellings.
The information provided water use information for 2000 and actual daily waste water flow recordings
for their peak month of May_ Other supporting data was provided, The evaluation covered 90 homes that are
representative of the subdivisions in Fuquay-Varina in accordance with 15A NCAC 2H .0219(1){3).
Based on the information submitted, the Division hereby approves the use of 75 GPD per bedroom
per dwelling for residential units (225 GPD per three bedroom home) in all applicable non -discharge permit
applications for future sewer line extensions and present, but not yet tributary projects for the Town of Fuquay-
Varina. The Division did note that the average flow per residence in February 2000 was 271 GPD. Regardless
of the adiu ted d4sidaily wastewater #low rate, at na. time shall the wastewater flaws cxceedthe of uent
limits defined in the Town's NPF permit for the treatment facilitor exco,ci the capacity of the sewers
downstream of any new sewer extension. — —
Please submit a separate letter to the Raleigh Regional Office that requests flow reductions for
specific previously permitted projects (indicate permit number, project name, permitted flow, new now
under redu do an[! the_ difference between them). If you have any questions oromm cents reearding this
matter, please contact Marie Doldovic at (919)733-5083 ext. 371.
S incese
f' Gregory J. Thorpe. Ph.D.
cc: Raleigh Regional Office
Flow Reduction File
1617 Mail Service Center. Raleigh. North Carolina 27699-161 7 Telephone 919-733-5083 Fax 919-715.6048
An Equal Opportunity Affirmative Action Employer 50�'r. recycled/ 1 D% post consumer paper
FAST TRACK SEWER APPLICATION
Bent Tree Subdivision
Phase 2 & 3
911 Fleming Loop Road
Fuquay-Varina, North Carolina 27526
March 13, 2019
Prepared for:
Bent Tree Investors, LLC
1210 Trinity Road, Suite 102
Cary, North Carolina 27513
Phone: 919.233.3886
r§[A L
.00
7�
l2
? -M
NC Dept Of Environmental Quality
Prepared By:
46
v� MCIUM&CREED
1730 Varsity Drive, Suite 500
Raleigh, North Carolina 27606
Phone: (919) 233.8091
Fax: (919) 233.8031
MS,C Project No. 04863-0015
APR - 5 2019
Meigh Regional Office
BENT TREE SUBDIVISION
Phase 2 & 3
March 13, 2019
PROJECT NARRATIVE
This project involves the construction of Phase 2 & 3 of a total 205-lot single
family subdivision in Fuquay-Varina, North Carolina and associated utility and
storm drainage infrastructure. Phase 2 & 3 of this development included 128 lots.
Summary of Sewer Lines to be permitted:
• Phase 2: 3,091 LF of 8-inch PVC gravity sewer
• Phase 3: 1,692 LF of 8-inch PVC gravity sewer
Phase 2 & 3: 128 lots @ 300 gpd/lot discharging 38,400 gpd
The sewage and wastewater collected by this system will be treated in the
Terrible Creek Wastewater Treatment Facility:
WWTP Facility Name: North Harnett Regional
Waste-Wa er Treatment Facility
WWTP Facility Permit #NC0021636
J
6�
Cashion, Ted
From: Cashion, Ted
Sent: Monday, May 20, 2019 9:18 AM
To: Jay Meyers ameyers@fuquay-varina.org); jkeeny@mckimcreed.com
Cc: Robinson, Jason
Subject: Sent Tree Subdivision - Phase 2 & 3 fast track sewer extension application
Jay and Jeremy,
We are reviewing the subject application. We need clarification on the receiving WWTP. The FTSE form that was
submitted shows N. Harnett WWTP as the receiving WWTP. However, the narrative states Terrible Creek is the receiving
WWTP, then right below it states N. Harnett is the WWTP, along with its permit number. Item IVA also notes N. Harnett
is the WWTP.
Please clarify which is the correct receiving WWTP.
If the receiving WWTP is N. Harnett, we'll need a FTSE form signed by Harnett Co. and submitted.
If the receiving WWTP is Terrible Creek, we'll need a FTSE form showing this.
You can email us the forms to expedite the process.
ted
Ted Cashion
Water Quality Regional Operations
Division of Water Resources
NC Department of Environmental Quality
Raleigh Regional Office
919-791-4254
ted.cashion@ncdenr.gov
1628 Mail Service Center
Raleigh, NC 27699-1628
3800 Barrett Drive
Raleigh, NC 27609
a
e f ��� ID
..,- <
pcpsrtrrent o[ FnvuIIiuncntat 4�nality
Subscribe to Collection System & Sewer Permitting Updates
Cashion, Ted
From:
Allen, Trent
Sent:
Tuesday, May 21, 2019 11:48 AM
To:
Cashion, Ted
Cc:
Robinson, Jason
Subject:
RE: Fuquay to discharge 27,000 gpd to N. Harnett WWTP
Thanks
From: Cashion, Ted
Sent: Tuesday, May 21, 2019 11:47 AM
To: Allen, Trent <trent.alien@ncdenr.gov>
Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov>
Subject: RE: Fuquay to discharge 27,000 gpd to N. Harnett WWTP
Thanks Trent. For the 2 projects we currently have in-house for Fuquay, they will have 65,400 gpd going to N. Harnett.
We'll cc you on the permits.
Thx
ted
Ted Cashion
Water Quality Regional Operations
Division of Water Resources
NC Department of Environmental Quality
Raleigh Regional Office
919-791-4254
ted.cashion@ncdenr.sov
1628 Mail Service Center
Raleigh, NC 27699-1628
3800 Barrett Drive
Raleigh, NC 27609
ID_ � E Q:�
f)epArLrcal ¢f Enviroaonental Quality
Subscribe to Collection System & Sewer Permitting Updates
Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be
disclosed to third parties unless the content is exempt by statute or other regulation.
From: Allen, Trent
Sent: Tuesday, May 21, 2019 11:44 AM
To: Cashion, Ted <ted.cashion@ncdenr.gov>
Cc: Robinson, Jason <iason.t.robinson(a)ncdenr.eov>
Subject: RE: Fuquay to discharge 27,000 gpd to N. Harnett WWTP
Ted,
Sorry for the delay. I took a look at their last flow acceptance letter we have and everything looks good. FQ has plenty of
allocated flow left and the plant is good also.
Trent
From: Cashion, Ted
Sent: Tuesday, May 21, 2019 11:40 AM
To: Allen, Trent <trent.allen@ncdenr;gov>
Cc: Robinson, Jason <iason.t.robinson@ncdenr.go_v>
Subject: Fuquay to discharge 27,000 gpd to N. Harnett WWTP
Hi again Trent,
Fuquay has submitted a fast track sewer extension application with 120 homes and 27,000 gpd to discharge to N.
Harnett WWTP.
Broadwell Trace is the name of the project.
Wanted to get your blessing before we issue the permit.
Thx
ted
Ted Cashion
Water Quality Regional Operations
Division of Water Resources
NC Department of Environmental Quality
Raleigh Regional Office
919-791-4254
ted.cashion@ncdenr.eov
1628 Mail Service Center
Raleigh, NC 27699-1628
3800 Barrett Drive
Raleigh, NC 27609
Cashion, Ted
From: Cashion, Ted
Sent: Thursday, June 06, 2019 9:17 AM
To: Jeremy M. Keeny; Jay Meyers Omeyers@fuquay-varina.org)
Cc: Robinson, Jason
Subject: RE: [External] RE: Bent Tree Subdivision - Phase 2 & 3 fast track sewer extension application
Following up on the email below —we need a FTSE form completed and signed by Harnett County.
You can email the completed form.
Thx
ted
Ted Cashion
Water Quality Regional Operations
Division of Water Resources
NC Department of Environmental Quality
Raleigh Regional Office
919-791-4254
ted.cashion@ncdenr.eov
1628 Mail Service Center
Raleigh, NC 27699-1628
3800 Barrett Drive
Raleigh, NC 27609
ID E
"�Q
OePaifteat of EnvIr mnien:al quality
Subscribe to Collection System & Sewer Permitting Updates
Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be
disclosed to third parties unless the content is exempt by statute or other regulation.
From: Cashion, Ted
Sent: Monday, May 20, 201910:00 AM
To: Jeremy M. Keeny <JKeeny@mckimcreed.com>; Jay Meyers ameyers@fuquay-varina.org) <jmeyers@fuquay-
varina.org>
Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov>
Subject: RE: [External] RE: Bent Tree Subdivision - Phase 2 & 3 fast track sewer extension application
Ok thanks Jeremy
Ted Cashion
Water Quality Regional Operations
Division of Water Resources
NC Department of Environmental Quality
Raleigh Regional Office
919-791-4254
ted.cashion@ncdenr.sov
1628 Mail Service Center
Raleigh, NC 27699-1628
3800 Barrett Drive
Raleigh, NC 27609
rv;,.artrr..c-t tf ;"n.frCa :rcn:.�, ruahly
Subscribe to Collection System & Sewer Permitting Updates
Email correspondence to and from this address may be subject to the North Carolina Public Records Low and may be
disclosed to third parties unless the content is exempt by statute or other regulation.
From: Jeremy M. Keeny <JKeen mckimcreed.com>
Sent: Monday, May 20, 2019 9:2S AM
To: Cashion, Ted <ted.cashion ncdenr, ov>; Jay Meyers (jmeyers(@fuguav-varina.org) <imeyers2fuguay-varina.org>
Cc: Robinson, Jason <iason.t.robinson ncdenr. ov>
Subject: [External] RE: Bent Tree Subdivision - phase 2 & 3 fast track sewer extension application
t rna` ins" -c nk click i�rrks �r Attachments unless you verify. Send al susplrldus small as.an attarhmenk to
Thanks Ted, I thought we had caught all of the references to the Terrible Creek WWTp, but we missed that one! N.
Harnett is the correct WWTp for treatment of this system. I will work on getting you the signed FTSE form from Harnett
as soon as possible.
From: Cashion, Ted <ted.cashion ncdenr. ov>
Sent: Monday, May 20, 2019 9:18 AM
To: Jay Meyers (ime ers fu ua-varina.or ) <-imeyers@fuguay-varina.ore>; Jeremy M. Keeny
<JKee ny2mckimcreed.com>
Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov>
Subject: Bent Tree Subdivision - Phase 2 & 3 fast track sewer extension application
Jay and Jeremy,
Cashion, Ted
From: Jeremy M. Keeny <J Keeny@m ckim creed. com>
Sent: Thursday, June 06, 2019 9:21 AM
To: Cashion, Ted; Jay Meyers ameyers@fuquay-varina.org)
Cc: Robinson, Jason
Subject: RE: [External] RE:: Bent Tree Subdivision - Phase 2 & 3 fast track sewer extension application
Attachments: Flow Tracking FV Bent Tree P2 and P3.pdf
• External email. Do noteliek hnk�,-or open attachments unless -you ver . Send all suspicious emaifas an attachrc in
en�s.saa€nnc.�tov_ .
My apologies Ted! In my head I had already forwarded this on to you. See attached the FTSE from Harnett.
Let me know if you need anything else!
Thanks,
Jeremy
From: Cashion, Ted <ted.cashion@ncdenr.gov>
Sent: Thursday, June 6, 2019 9:17 AM
To: Jeremy M. Keeny <JKeeny@mckimcreed.com>; Jay Meyers (jmeyers@fuquay-varina.org) <jmeyers@fuquay
varina.org>
Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov>
Subject: RE: [External] RE: Bent Tree Subdivision - Phase 2 & 3 fast track sewer extension application
Following up on the email below —we need a FTSE form completed and signed by Harnett County.
You can email the completed form.
Thx
ted
Ted Cashion
Water Quality Regional Operations
Division of Water Resources
NC Department of Environmental Quality
Raleigh Regional Office
919-791-4254
ted.cashion@ncdenr.eov
1628 Mail Service Center
Raleigh, NC 27699-1628
3800 Barrett Drive
Raleigh, NC 27609