f5�11Y C 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
Division of Water Resources I ° UCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION
AYFT4r'.;'4'P, ',°{'t";IflK'f.7 fcE=Et'f-
This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been
certified by a professional engineer and the applicant that the project meets the requirements of 15A NCAC 02T and the Division's
Minimum Design Criteria and that plans, specifications and supporting documents have been prepared in accordance with, 15A
NCAC 02T, 15A NCAC 02T.0300, Division policies and good engineering practices.
While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design
documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design
calculations; and project specifications referenced in 15A NCAC 02T .0305 and the applicable minimum design criteria. These
documents shall be available upon request by the Division.
Projects that are deemed permitted (do not require a permit from the Division) are explained in 15A NCAC 02T.0303.
Projects not eligible for review via the fast track process (must be submitted for full technical review):
➢ Projects that require an environmental assessment in accordance with 15A NCAC 1C .0100;
➢ Projects that do not meet any part of the minimum design criteria (MDC) document;
➢ Projects that involve a variance from the requirements of 15A NCAC 2T;
➢ Pressure sewer systems utilizing septic tank -effluent pumps (STEPS) or simplex grinder pumps;
➢ STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains);
➢ Vacuum sewer systems.
General - When submitting an application, please use the following instructions as a checklist in order to ensure all required
items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time
and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional
processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit
one original and one copy of the application and supporting documentation.
A. One Original and One Copy of Application and Supporting Documents
® Required unless otherwise noted
B. Cover Letter (Required for All Application Packages):
N List all items included in the application package, as well as a brief description of the requested permitting action.
➢ Be specific as to the system type, number of homes served, flow allocation required, etc.
➢ If necessary for clarity, include attachments to the application form.
C. Application Fee (All New and Major Modification Application Packages):
® Submit a check or money order in the amount of $480.00 dated within 90 days of application submittal.
➢ Payable to North Carolina Department of Environmental Quality (NCDEQ)
D. Fast Track (Form: FTA 04-16) Application (Required for All Application Packages):
® Submit the completed and appropriately executed application.
➢ If necessary for clarity or due to space restrictions, attachments to the application may be made.
❑ If the Applicant Type in Item 1.2 is a corporation or company, provide documentation it is registered for business with
the Notch Carolina Secretary of State.
❑ If the Applicant Type in Item 1.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of
Deeds in the county of business.
® The Project Name in Item I1.1 shall be consistent with the project name on the flow acceptance letters, agreements, etc.
® The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North
Carolina licensed Professional Engineer.
® The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T .0106(b).
Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is
provided from a person who meets the criteria in 15A NCAC 02T .0106(b).
INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Pagel of 3
E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (If Applicable):
❑ Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility.
➢ Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different.
➢ The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one
year prior to the application date.
➢ Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate G.S. 143-
215.67 a .
➢ Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE.
F. Site Maps (All Application Packages):
® Submit an 8.5-inch x 11-inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project
area and closest surface waters.
➢ Location of the project (gravity sewer, pump stations & force main)
Downstream connection points and permit number (if ]mown) for the receiving sewer
❑ Include a street level map (aerial) showing general project area so that Division staff can easily locate it in the field.
G. Existing Permit (All Modification Packages):
® Submit the most recently issued existing permit.
❑ Provide a list of any items within the permit the Applicant would like the Division to address during the permit
modification (i.e., permit description, flow allocation, treatment facility, etc.).
H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station):
❑ Per 15A NCAC 02T .0305(h)( I ), submit documentation of power reliability for pumping stations,
➢ This alternative is only available for average daily flows less than 15,000 gallons per day
➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is
compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(b)) or
proposed contractor, stating that "the portable power generation unit or portable, independently -powered pumping
units, associated appurtenances and personnel are available for distribution and operation of this pump station"
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump
stations' storage capacities and the rotation schedule of the portable power source or pump, including travel
timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification)
I. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities):
❑ Per 15A NCAC 02T .0115(a)(1) provide the Certificate of Public Convenience and Necessity from the North Carolina
Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by
the sewer extension, or
❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an
application for a franchise has been received and that the service area is contiguous to an existing franchised area or
that franchise approval is expected.
J. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold):
❑ Home/Property Owners' Associations
❑ Per I5A NCAC 02T .0115(c ), submit the properly executed Operational Agreement ( FORM: HOA).
❑ Per 15A NCAC 02T .0115(c), submit a copy of the Articles of Incorporation, Declarations and By-laws.
❑ Developers of lots to be sold
❑ Per 15A NCAC 02T .0115(b), submit the properly executed Operational Agreement (FORM. DEV ).
For more information, visit the Division's collection systems website
INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 2 of 3
THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND
MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE:
REGIONAL OFFICE
ADDRESS
COUNTIES SERVED
Asheville Reamnat Office
2090 US Highway 70
Avery, Buncombe, Burke, Caldwell, Cherokee,
Water Quality Section
Swannanoa, North Carolina 28778
Clay, Graham, Haywood, Henderson, Jackson,
(S28) 296-4500
Macon, Madison, McDowell, Mitchell, Polk,
(828) 299-7043 Fax
Rutherford, Swain, Transylvania, Yancey
Fayetteville Regional Office
225 Green Street Suite 714
Anson, Bladen, Cumberland, Hamett, Hoke,
Water Quality Section
Fayetteville, North Carolina 28301-5094
Montgomery, Moore, Robeson, Richmond,
(910) 433-3300
Sampson, Scotland
(910)486-0707 Fax
Mooresville Regional Office
610 E. Center Avenue
Alexander, Cabarrus, Catawba, Cleveland,
Water Quality Section
Mooresville, North Carolina -28115
Gaston, Iredell, Lincoln, Mecklenburg, Rowan,
(704) 663-1699
Stanly, Union
(704)663-6040 Fax
Raleigh Regional Office
1628 Mail Service Center
Chatham, Durham, Edgecombe, Franklin,
Water Quality Section
Raleigh, North Carolina 27699-1628
Granville, Halifax, Johnston, Lee, Nash,
(919) 791-4200
Northampton, Orange, Person, Vance, Wake,
(919) 788-7159 Fax
Warren, Wilson
Washington Regional Office
943 Washington Square Mall
Beaufort, Bartle, Camden, Chowan, Craven,
Water Quality Section
Washington, North Carolina 27869
Currituck, Dare, Gates, Greene, Hertford, Hyde,
(252) 946-6481
Jones, Lenoir, Martin, Pamlico, Pasquotank,
(252) 975-3716 Fax
Perquimans, Pitt, Tyrrell, Washington, Wayne
Wilminaton Regional Office
127Cardinal Drive Extension
Brunswick, Carteret, Columbus, Duplin, New
Water Quality Section
Wilmington, North Carolina 28405
Hanover, Onslow, Pander
(910) 796-7215
(910)350-2004 Fax
Winston-Salem Regional Office
450 W. Hanes Mill Road
Suite 300
Alamance, Allegheny, Ashe, Caswell, Davidson,
Davie, Forsyth, Guilford, Rockingham, Randolph,
Water Quality Section
Winston-Salem, North Carolina 27105
Stokes, Surry, Watauga, Wilkes, Yadkin
(336) 776-9800
INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 3 of 3
State of North Carolina
Department of Environmental Quality
DWR Division of Water Resources
ISA NCAC 02T .0300 —FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
Division of Water Resources / yyFTA 04-16 & SUPPORTING DOCUMENTATION
Application Number: 1 �t� OD3W1017M(to be completed by DwR)
All itemsmustbe completed or the avolication will be returned
I. APPLICANT INFORMATION:
1. Applicant's name: Harnett Regional Water (company, municipality, HOA, utility, etc.)
2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility
❑ Federal ® State/County ❑ Municipal ❑ Other
3. Signature authority's name: Steve Ward per 15A NCAC 02T .0106(b)
Title: Director of Public Utilities
4. Applicant's mailing address: PO Box 11.19
City: Lillington State: North Carolina Zip: 27546-
5. Applicant's contact information:
Phone number: (910) 892-7575 Email Address: sward a hamett.org
H. PROJECT INFORMATION:
I. Project name: Forest Oaks Phase V
2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project
If a modification, provide the existing permit number: W00038617 and issued date: July 28, 2016
If new construction but part of a master plan, provide the existing permit number: W000_
3. County where project is located: Harnett
4. Approximate Coordinates (Decimal Degrees): Latitude: 35.3077' Longitude:-78.9678'
5. Parcel ID (if applicable): 0506-96-2218.000
(or Parcel ID to closest downstream sewer)
M. CONSULTANT INFORMATION:
Professional Engineer: C. Scott Brown License Number: 27452
Firm: 4D Site Solutions. Inc
Mailing address: 409 Chicago Drive. Suite 112
City: Fayetteville State: NC Zip: 28306-_
Phone number: (910) 426-6777 Email Address: sbrown@4dsitesolutions.com
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
Facility Name: South Harnett Regional W W Treatment Plant Permit Number: NCO089366
Owner Name: Harnett County Department of Public Utilities (HCDPU)
V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF):
1. Permit Number(s): W00035410 Downstream (Receiving) Sewer Size: 8 inch
System Wide ('ollection System Permit NumberstLiLa plicable : WQCS_
Owner Name(s): Harnett Regional Water
FORM: FTA 04-16 Page I of 5
VL GENERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes []No NN/A
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV ) been attached?
❑ Yes ❑No NN/A
3. If the Applicant is a Home/1'roperty Owners' Association, has an.Operational Agreement (FORM' HOA1 been attached?
❑ Yes ❑No NN/A
4. Origin of wastewater: (check all that apply)
® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash
❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels
❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse
❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash
❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment)
5. Nature of wastewater: 100 % Domestic/Commercial % Commercial
% Industrial (See 15A NCAC 02T._0103(201)
"Is there Pretreatment Program in effect? ❑ Yes ❑ No
6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ❑ No
➢ If yes, provide a cony of flow reduction approval letter
7. Summarize wastewater generated by project:
8.
Establishment Type (see 2ZT.0114(f))
Daily Design Flow ""
No. of Units
Flow
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
Total
0 GPD
a See 15A NCAC 02T 01 14(b). (d•). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use
areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals
as defined in G_S, 42A-44).
b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table ISA NCAC 02T.01141 shall
be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114)
➢ Do not include future flows or previously permitted allocations
If permitted flow is zero, indicate why:
❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line
N Flow has already been allocated in Permit Number: W00035410
❑ Rehabilitation or replacement of existing sewer with no new flow expected
❑ Other (Explain): _
FORM: PTA 04-16 Page 2 of 5
Vn. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02FF .0305 & XIDC (Gravity Sewers):
1. Summarize gravity sewer to be permitted:
Size (inches)
Length (feet)
Material
8
228
PVC
➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC
VHL PUMP STATION DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Puma Stations/Force Mains):
COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
I. Pump station number or name: Existing pump station
2. Approximate Coordinates (Decimal Degrees): Latitude: 35.310475' Longitude:-78.963272'
3. Design flow of the pump station: millions gallons per day (firm capacity)
4. Operational point(s) of the pump(s): _ gallons per minute at _ feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches)
Length (feet)
Material
6
168
PVC
6. Power reliability in accordance with 15A NCAC 021" 0305(h)(1):
❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T ,0305(h)(1)(B):
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
Y Must be permanent to facility
Or if the pump station has an average daily flow less than 15,000 gallons per day:
❑ Portable power source with manual activation, quick -connection receptacle and telemetry 15A NCAC 02T
.0305(h)(1)(C)
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C):
Y It shall be demonstrated to the Division that the portable source is. owned or contracted by the applicant (draft agreement)
and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations'
storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be
provided in the case of a multiple station power outage.
FORM: FTA 04-16 Page 3 of
Di. SETBACKS & SEPARATIONS - (02B .0200 & 15A NCAC 02T .0305(f)):
1. Does the project comply with all separations found in 15A NCAC 021' .0305(t) & (g)
➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be crovided for sewer systems:
® Yes ❑ No
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below (vertical)
24 inches
Water mains (vertical -water over sewer including in benched trenches)
18 inches
Water mains horizontal
10 feet
Reclaimed water lines vertical - reclaimed over sewer)
18 inches
Reclaimed water lines horizontal - reclaimed over sewer)
2 feet
"Any private or public water supply source, including any wells, WS-I waters of Class I or
Class II impounded reservoirs used as a source of drinking water
100 feet
*Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal
high water or tide elevation) and wetlands see item IX.2
50 feet
**Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches
10 feet
Any building foundation
5 feet
Any basement
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade vertical
36 inches
➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 021 0305 t cannot be achieved.
**Stream classifications can be identified using the Division's NC Surface Water Classifications webpage
Y If noncompliance with 021,0305(f) or e), see Section X of this application
2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ®Yes []No ❑ N/A
1> See the Division's draft separation requirements for situations where separation cannot be meet
Y No variance is required if the alternative design criteria specified is utilized in design and construction
➢ As built documents should reference the location of areas effected
3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .02009 ❑ Yes ❑ No Z N/A
This would include Trout Buffered Streams per 15A NCAC 213.0202
4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No
individual permits or 401 Water Quality Certifications?
Y Information can be obtained from the 401 & Buffer Permitting Branch
5. Does project comply with 15A NCAC' 02. 0105(c)I6) (additional permits/certifications)? ® Yes []No
Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have
been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and
sedimentation control plans, stormwater management plans, etc.).
6. Does this project include any sewer collection lines that are deemed "high -priority?"
Per 15A NCAC 02T 0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer
positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer.
❑ Yes ❑ No ® N/A
p If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permittee or its representative at least once every six -months and
inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit.
FORM: FTA 04-16 Page 4 of 5
X. CERTIFICATIONS:
1. Does the submitted system comply with 15A NC AC 02T, the Minimum Design Criteria for the Permitting of PumI ,Stations
and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable?
2.
® Yes ❑ No
If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents
for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting
documents.
I,
Engineer's Certification:
SCE (�row*j
Engineer's name from Application Item III.1_)
that this application for
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications,
engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best
of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track
Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain
portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this
material and have judged it to be consistent with the proposed design.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation.
North Carolina Professional Engineer's seal, signature, and date:
022452
� •'•FNGINEEe'��•';
,>SCOTT BP° l-I fin'
3. Applicant's Certification per 15ANCAC 02T .0106(b):
I Z:>'t-L v�,_ U,� C'Irce attest that this application for
(Signature Authority's name & title from Application Item I.3.)
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of
this application are not completed and that if all required supporting documentation and attachments are not included, this
application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -
discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties,
injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a
condition of this permit be violated. I also understand that if all required parts of this application package are not completed
and that if all required supporting information and attachments are not included, this application package will be returned to
me as incomplete.
NOTE — In accordance with General Statutes 143-CIS 4 and 143.215.6% any person who knowingly makes any false
statement, representation, or certification in any appli t' n package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as ciyfil p n ties up to $25,000 per violation.
Signature:
Date: / 1 6O r (7
FORM: FTA 04-16 Page 5 of 5
State of North Carolina
Department of Environment and Natural Resources
Division of Water Quality
Flow Tracking/Acceptance for Sewer Extension Permit Applications
(FTSE 06-13)
Project Applicant Name: tdAU57-7-7 1 \ E7�-� .T-0A)AL-- U—)A 7-zf/2
Project Name for which flow is being requested: Forest Oaks Phase V Modification
More than one FTSE maybe required for a single project if the owner of the WJUP is not responsible for all pump
stations along the route of the proposed wastewater flow.
I. Complete this section only if you are the owner of the wastewater treatment plant.
a. WWTP Facility Name: South Harnett Regional WWTP
b. WWTP Facility Permit #: NCO088366
AU lows are in MGD
c. WWTP facility's permitted flow 15
d. Estimated obligated flow not yet tributary to the WWTP 5.245
e. WWTP facility's actual avg. flow 5.696
f. Total flow for this specific request 0.000
g. Total actual and obligated flows to the facility 10.941
h. Percent of permitted flow used 72.94%
II. Complete this section for each pump station you are responsible for along the route of this
proposed wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A) (B) (C) (D)=(B+C) (E)=(A-D)
Design Obligated,
Pump Average Daily Approx. Not Yet Total Current
Station Firm Flow** Current Avg. Tributary Flow Plus
(Name or Capacity,* (Firm / pl), Daily Flow, Daily Flow, Obligated Available
Number) MGD MGD MGD MGD Flow Capacity***
SLS 55 0.338 0.135 0.020 0.115 0.135 0.000
SLS 72 1.656 0.662 0.197 0.400 0.597 .065
* The Firm Capacity of any pump station is defined as the maximum pumped flow that
can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking
factor (pf) not less than 2.5.
*** A Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the WWTP where the Available Capacity is < 0.
Page 1 of 6
FTSE 06-13
Certification Statement:
I Steve Ward certify to the best of my knowledge that the addition of
the volume of wastewater to be permitted in this project has been evaluated along the route to the
receiving wastewater treatment facility and that the flow from this project is not anticipated to
cause any capacity related sanitary sewer overflows or overburden any downstream pump station
en route to the receiving treatment plant under normal circumstances, given the implementation of
the planned improvements identified in the planning assessment where applicable. This analysis
has been performed in accordance with local established policies and procedures using the best
available data. This certification applies to those items listed above in Sections I and II plus all
attached planning assessrrWnt addendums for which I am the responsible party. Signature of this
form indicates accktanQGf this wastewater flow.
Signing Official Signature
Date
Page 2 of 6
FTSE 06-13
40W.
f C
1 'sit
M
SRI
M�Mmm
April 23, 2019
NCDEQ
Fayetteville Regional Office
Attn: Johnathan Watts
225 Green Street, Suite 714
Fayetteville, NC 28301
RE: Revised Sewer Application, Forest Oaks Phase V (WQ0038617), Harnett County,
North Carolina
Johnathan;
Enclosed is the sewer application revision to the original approval for Forest Oaks Phase
V (WQ0038617). The sewer was redesigned for the last section of the project to be
installed through the open space in lieu of between lot lines as previously approved.
This will eliminate the utility easement between the lots and make it more convenient
to perform maintenance/repairs on the sewer main and force main. The redesign result
in additional length for both the gravity main and force main. The $480 review fee is
also enclosed with the remainder of the application package.
I look forward to working with you on this project. If you have any questions or
concerns, please feel free to contact us.
Sincerely,
41) Site Solutions, Inc.
Scot Brown, PE
sbrown@4dsitesolutions.com
Enclosure'
409 Chicago Drive, Suite 112, Fayettevilte, NC 28306
office 1 910-426-6777 fax j 910-426-5777
On time, every time. I www.4Dsitesolutions.corn
State of North Carolilk,
DWR
Department of Environmental Quality
Division of Water Resources
15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION
Application Number: (to be completed by DWR)
All items mustbe completed or the application will be returned
L APPLICANT INFORMATION:
I. Applicant's name: Harnett Regional Water (company, municipality, HOA,. utility, etc.)
2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Private) -O ed P b ' t
❑ Federal ® State/County ❑ Municipal ❑ Other D C-KW
3. Signature authority's name: Steve Ward per 1 5A NC'AC 02T .0106 b) I�
Title: Director of Public Utilities APR 2 5 2019
4. Applicant's mailing address: PO Box 1119
City: Lillineton State: North Carolina Zip: 27546-_ WORCIS
5. Applicant's contact information:
Phone number: (910) 892-7575 Email Address: sward@hamett.ore
EL PROJECT INFORMATION:
1. Project name: Forest Oaks Phase V
2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project
If a modification, provide the existing permit number: W00038617 and issued date: July 28, 2016
If new construction but part of a master plan, provide the existing permit number: W000
3. County where project is located: Harnett
4. Approximate Coordinates (Decimal Degrees): Latitude: 35.3077' Longitude:-78.96V
5. Parcel ID (if applicable): 0506-96-2218,000
(or Parcel ID to closest downstream sewer)
409 CHICAGO DRIVE
SUITE 112.
*"480.00
Four Hundred Eighty and Q01100 � DOLLARS
y 1�
%,t'
8104'ForestOaks`Ph'V1,sse'
RU I HURIZEU SI
rnuaenv u.
FORM: FTA 04-16 Page 1 of 5
Central Files: APS _ SWP
5/1/2019
Permit Number WQ0038617
Program Category
Non -discharge
Permit Type
Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions
Primary Reviewer
trent.allen
Coastal SWRule
Permitted Flow
0
Facility
Permit Tracking Slip
Status
Project Type
Active
Major modification
Version
Permit Classification
1.10
Individual
Permit Contact Affiliation
Facility Name Major/Minor Region
Forest Oaks Phase V Minor Fayetteville
Location Address County
Harnett
Facility Contact Affiliation
Owner
Owner Name Owner Type
Harnett County Department of Public Utilities Non -Government
Owner Affiliation
Steve Ward
Director Interim Public Utilities of
PO Box 1119
Dates/Events Lillington NC 27546111
Scheduled
Orig Issue App Received Draft Initiated Issuance
7/28/2016 4/25/2019
Regulated Activities
Wastewater collection
Public Notice Issue Effective Expiration
5/1/2019 5/1/2019
Requested/Received Events
Additional information requested
Additional information received
Outfall
Waterbody Name Stresmindex Number Current Class Subbasin