HomeMy WebLinkAbout87858 Equipment Supply Fact Sheet GW-REM 31May2019NCDEQ / DWR / NPDES
EXPEDITED FACT SHEET - PERMIT RENEWAL
NPDES Permit NCO087858
Joe R. Corporon, P.G., Expedited Permitting and Compliance Unit 31May2019
Facility Information
Facility Name:
Equip ment &Supply, Inc.
Applicant Address:
4507 Highway 74 West, Monroe, NC 28110
Facility Address:
Same
Contact & Consultant
Information:
Jim Diggs VP - [contact - tim@equipsy.com]
704-289-6565
Permitted Flow:
0.0216 MGD
WWTP Classification:
Class PC-1 (groundwater remediation - GW-REM)
Permit Status:
Renewal
County:
Union
Stream Characteristics
Receiving Stream:
UT Stewarts Creek
(conveyance ditch)
Regional Office:
MRO
Basin/Subbasin:
Yadkin / 03-07-14
USGS Topo Quad:
G16SE/ Bakers
Stream Classification:
WS-III
Segment 13-17-36-9-(1)
Permit Writer:
Joe R. Corporon, P.G.
303(d) Listed:
No
Date:
31May2019
Drainage Area (mi ):
< 0.5
AARIF
Lat_ 351 02' 34 N Long. 801 36' 42" W
Summer 7Q 10 (cfs)
0.0
Winter 7Q10 (cfs):
0.0
30Q2 (cfs):
0.0
Average Flow (cfs):
NA
IWC (%):
100%
Background Summary - This groundwater remediation system was first permitted in January 2005, flow -
limited at 0.0216 MGD. Recent flows however average much less at—0.0032 MGD (2018-2019). Records
suggest that volatile organic compounds (VOCs) as chlorinated hydrocarbons were lost to the environment
stemming from the Permittee's past use of a single 55-gallon drum of solvent (TCE) inadvertently leaked
upstream of Stewarts Creek, classified WS-III. Site -assessment soil and groundwater sampling detected
TCE and various chlorinated -hydrocarbon "daughter -products of decomposition" [see NPDES permit
effective 0lFeb2005].
Receiving -Stream - This facility discharges via a man-made conveyance [ditch] under zero -flow receiving -
stream conditions [summer 7Q10 flow = 0.0 cfs] to an unnamed tributary (UT) to Stewarts Creek in the
Yadkin -Pee Dee River Basin. Stewarts Creek is currently classified WS-III and is not listed as impaired [not
303d-listed in the Basin Plan].
Compliance - WET -tests records indicated all "Pass." After the initial treatment -system start-up, VOCs
were not detected in the effluent above test -method practical quantitation levels (PQLs) suggesting an
appropriately designed and well -operated treatment facility. DWR relaxed the monitoring frequencies from
2/Month to Monthly for the 2010 and 2015 permit renewals — no changes recommended.
Summary of Renewal Changes: Updated site map and text to include Rule citations; updated facility
description [Supplement to Cover Sheet]; updated text for eDMR submittal [see section A. (3.)].
Fact Sheet
Renewal May2019 -- NPDES Permit NCO087858
Page 1 of 1