HomeMy WebLinkAbout87858 Equipment Supply Fact Sheet GW-REM 31May2019NCDEQ / DWR / NPDES EXPEDITED FACT SHEET - PERMIT RENEWAL NPDES Permit NCO087858 Joe R. Corporon, P.G., Expedited Permitting and Compliance Unit 31May2019 Facility Information Facility Name: Equip ment &Supply, Inc. Applicant Address: 4507 Highway 74 West, Monroe, NC 28110 Facility Address: Same Contact & Consultant Information: Jim Diggs VP - [contact - tim@equipsy.com] 704-289-6565 Permitted Flow: 0.0216 MGD WWTP Classification: Class PC-1 (groundwater remediation - GW-REM) Permit Status: Renewal County: Union Stream Characteristics Receiving Stream: UT Stewarts Creek (conveyance ditch) Regional Office: MRO Basin/Subbasin: Yadkin / 03-07-14 USGS Topo Quad: G16SE/ Bakers Stream Classification: WS-III Segment 13-17-36-9-(1) Permit Writer: Joe R. Corporon, P.G. 303(d) Listed: No Date: 31May2019 Drainage Area (mi ): < 0.5 AARIF Lat_ 351 02' 34 N Long. 801 36' 42" W Summer 7Q 10 (cfs) 0.0 Winter 7Q10 (cfs): 0.0 30Q2 (cfs): 0.0 Average Flow (cfs): NA IWC (%): 100% Background Summary - This groundwater remediation system was first permitted in January 2005, flow - limited at 0.0216 MGD. Recent flows however average much less at—0.0032 MGD (2018-2019). Records suggest that volatile organic compounds (VOCs) as chlorinated hydrocarbons were lost to the environment stemming from the Permittee's past use of a single 55-gallon drum of solvent (TCE) inadvertently leaked upstream of Stewarts Creek, classified WS-III. Site -assessment soil and groundwater sampling detected TCE and various chlorinated -hydrocarbon "daughter -products of decomposition" [see NPDES permit effective 0lFeb2005]. Receiving -Stream - This facility discharges via a man-made conveyance [ditch] under zero -flow receiving - stream conditions [summer 7Q10 flow = 0.0 cfs] to an unnamed tributary (UT) to Stewarts Creek in the Yadkin -Pee Dee River Basin. Stewarts Creek is currently classified WS-III and is not listed as impaired [not 303d-listed in the Basin Plan]. Compliance - WET -tests records indicated all "Pass." After the initial treatment -system start-up, VOCs were not detected in the effluent above test -method practical quantitation levels (PQLs) suggesting an appropriately designed and well -operated treatment facility. DWR relaxed the monitoring frequencies from 2/Month to Monthly for the 2010 and 2015 permit renewals — no changes recommended. Summary of Renewal Changes: Updated site map and text to include Rule citations; updated facility description [Supplement to Cover Sheet]; updated text for eDMR submittal [see section A. (3.)]. Fact Sheet Renewal May2019 -- NPDES Permit NCO087858 Page 1 of 1