Loading...
HomeMy WebLinkAbout20190694 Ver 1_PCN Form Submission_20190527DR 02*10n of Water R"Ourc" Pre -Construction Notification (PCN) Form September 29, 2018 Ver 3 Initial Review Has this project met the requirements for acceptance into the review process?* r Yes r No Is this project a public transportation project?* r Yes r No CharxJe only if needed. BIMS # Assigned 20190694 Is a payment required for this project?* r No payment required r Fee received r Fee needed - send electronic notification Select Project Reviewer* Stephanie Goss:eads\szgoss Information for Initial Review 1a. Name of project: Rollingwood driveways 1a. Who is the Primary Contact?* Scott Lee 1 b. Primary Contact Email:* scott@scottleehomes.com Date Submitted 5/27/2019 Nearest Body of Water Neuse River Basin Neuse Water Classification WS -IV, NSW Site Coordinates Latitude: 35.6560 A. Processing Information County (or Counties) where the project is located: Johnston Is this project a public transportation project?* r Yes r No Longitude: -78.4480 1a. Type(s) of approval sought from the Corps: V Section 404 Permit (wetlands, streams and waters, Clean Water Act) F Section 10 Permit (navigable waters, tidal waters, Rivers and Harbors Act) 1 b. What type(s) of permit(s) do you wish to seek authorization? P Nationwide Permit (NWP) F- Regional General Permit (RGP) r- Standard (IP) Version# * 1 Reviewing Office* Raleigh Regional Office - (919) 791-4200 1c. Primary Contact Phone:* (919)553-2085 1c. Has the NWP or GP number been verified by the Corps? r Yes r No Nationwide Permit (NWP) Number: NWP Numbers (for multiple NWPS): 1d. Type(s) of approval sought from the DWR: r 401 Water Quality Certification - Regular F Non -404 Jurisdictional General Permit F Individual Permit 14 - Linear transportation 1e. Is this notification solelyfor the record because written approval is not required? For the record only for DWR 401 Certification: For the record only for Corps Permit: F 401 Water Quality Certification - E)press P Riparian Buffer Authorization 1f. Is this an after -the -fact permit application?* r Yes r No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? r Yes r No 19. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? r Yes r No Acceptance Letter Attachment 1h. Is the project located in any of NC's twenty coastal counties? r Yes r No 1j. Is the project located in a designated trout watershed? r Yes r No B. Applicant Information 1d. Who is applying for the permit? Q Owner W Applicant (other than owner) 1e. Is there an Agent/Consultant for this project? C Yes r No 2. Owner Information 2a. Name(s) on recorded deed: Scott Lee Homes, Inc 2b. Deed book and page no.: 05204,0382 2c. Responsible party: Scott Lee 2d. Address Street Address 104 State Ave Ste 103 Address Line 2 City Clayton Postal / Zip Code 27542 2e. Telephone Number: (919)553-2085 2g. Email Address:* scott@scottleehomes.com 3. Applicant Information (if different from owner) ......... ......... 3a. Name: Scott Lee State / Rwince / Fbjion NC Country Johnston 2f. Fax Number: r Yes r No rYes rNo 3b. Business Name: Scott Lee Homes, Inc 3c. Address Street Address 104 State Ave Ste 103 Address Line 2 City Clayton Postal / Zip Code 27542 3d. Telephone Number: (919)553-2085 3f. Email Address:* scott@scottleehomes.com C. Project Information and Prior Project History 1. Project Information 1b. Subdivision name: (if appropriate) Rollingwood 1c. Nearest municipality/ town: Clayton 2. Project Identification 2a. Property Identification Number: 166914-44-2111,166914-34-9141 2c. Project Address Street Address 201 and 209 Dogwood Ave Address Line 2 atY Clayton Postal / Zip (ode 27520 3. Surface Waters 3a. Name of the nearest body of water to proposed project:* Neuse River 3b. Water Resources Classification of nearest receiving water:* WS -IV, NSW 3c. What river basin(s) is your project located in?* Neuse 3d. Please provide the 12 -digit HUC in which the project is located. 030202011103 4. Project Description and History Slate / Ftwinoe / Ibgion North Carolina Country Johnston 3e. Fax Number: 2b. Property size: -1.6 State / Frwinoe / Pagion NC Country Johnston 4a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application:* This is eAsting S/D, 2 undeveloped lots are now being developed, the buffer authorization is for the 2 driveways crossing a buffered feature. 4b. Have Corps permits or DWR certifications been obtained for this project (including all prior phases) in the past?* f Yes r No r Unknown 4d. Attach an 8 1/2 X11 excerpt from the most recent version of the USGS topographic map indicating the location of the project site. (for DWR) Quad.pdf 455.26KB 4e. Attach an 8 1/2 X11 excerpt from the most recent version of the published County NRCS Soil Survey map depicting the project site. (for DWR) soil survey.pdf 550.85KB 4f. List the total estimated acreage of all existing wetlands on the property: 0 4g. List the total estimated linear feet of all existing streams on the property: -200 feet 4h. Explain the purpose of the proposed project:* Install 2 individual driveways for 2 individual home sites on 2 lots in a existing S/D. The crossings are to access the property on the other side of the buffered feature for residential use. 4i. Describe the overall project in detail, including indirect impacts and the type of equipment to be used:* I driveway will be installed for each building lot. (lot 95 and lot 93) There are 2 building lots as seen on the soil survey attachment. The lots do not touch each other. Each driveway will cross an wasting Neuse Buffered feature. Each crossing Will be a culvert crossing. 4j. Please upload project drawings for the proposed project. Rolling Wood Driveways 04-03-19 marked.pdf 2.42MB 5. Jurisdictional Determinations 5a. Have the wetlands or streams been delineated on the property or proposed impact areas?* r Yes r No f• Unknown Comments: Neuse buffer determination by Raleigh Regional Office 5b. If the Corps made a jurisdictional determination, what type of determination was made? r Preliminary r Approved r Not Verified r Unknown r WA Corps AID Number: 5c. If 5a is yes, who delineated the jurisdictional areas? Name (if known): Agency/Consultant Company: Other: 5d1. Jurisdictional determination upload Rollingwood Stream Call Letter - 121616.pdf 6. Future Project Plans 1.94MB 6a. Is this a phased project?* r Yes r No Are any other NWP(s), regional general permit(s), or individual permits(s) used, or intended to be used, to authorize any part of the proposed project or related activity? non reporting NW 14 D. Proposed Impacts Inventory 1. Impacts Summary 1a. Where are the impacts associated with your project? (check all that apply): F Wetlands r Streams -tributaries W Buffers F- Open Waters r Pond Construction 6. Buffer Impacts (for DWR) 6a. Project is in which protect basin(s)? Check all that apply. V Neuse r Tar -Pamlico F Catawba r Randleman F Goose Creek r Jordan Lake F Other 6b. Impact Type 6c. Per or Temp 6d. Stream name 6e. Buffer mitigation required? 6f. Zone 1 impact 6g. Zone 2 impact culvert crossing lot 93 P UT Neuse River No 1,962 660 culvert crossing lot 95 P UT Neuse River No 1,309 653 6h. Total buffer impacts: Zone 1 Zone 2 Total Temporary impacts: 0.00 0.00 Zone 1 Zone 2 Total Permanent impacts: 3,271.00 1,313.00 Zone 1 Zone 2 Total combined buffer impacts: 3,271.00 1,313.00 6i. Comments: Supporting Documentation Rolling Wood Driveways 04-03-19 marked.pdf 2.42MB E. Impact Justification and Mitigation 1. Avoidance and Minimization 1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project: Crossing perpendicular to stream, driveways are as narrow as possible and still be safe. Not impacting any wetlands with the crossing. 1b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques: No construction of crossing in periods of high storm flow. No work if heavy rains are forecast, area will be temporarily stabilized at end of each work day, installed with little impact to area as possible and practical. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? f Yes r No 2b. If this project DOES NOT require Compensatory Mitigation, explain why: F. Stormwater Management and Diffuse Flow Plan (required by DWR) 1. Diffuse Flow Plan 1a. Does the project include or is it adjacent to protected riparian buffers identified within one of the NC Riparian Buffer Protection Rules? r Yes r' No What type of SCM are you providing? [ Level Spreader Vegetated Conveyance (lower SHWT) Wetland Swale (higher SHWT) Other SCM that removes minimum 30% nitrogen P Proposed project will not create concentrated stormwater flow through the buffer Diffuse Flow Documentation 2. Stormwater Management Plan 2a. Is this a NCDOT project subject to compliance with NCDOT's Individual NPDES permit NCS000250?* C Yes r No 2b. Does this project meet the requirements for low density projects as defined in 15A NCAC 02H .1003(2)? r Yes r No Comments: G. Supplementary Information 1. Environmental Documentation 1a. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land?* r Yes r No 2. Violations (DWR Requirement) 2a. Is the site in violation of DWR Water Quality Certification Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), or DWR Surface Water or Wetland Standards or Riparian Buffer Rules (15A NCAC 2B.0200)?* r Yes r No 3. Cumulative Impacts (DWR Requirement) 3a. Will this project result in additional development, which could impact nearby downstream water quality?* r Yes r No 3b. If you answered "no," provide a short narrative description. This is an ebsting S/D greater than 20 years old, 2 undeveloped lots are now being developed, should not affect anything down stream. 4. Sewage Disposal (DWR Requirement) 4a. Is sewage disposal required by DWR for this project?* r Yes C No C WA 5. Endangered Species and Designated Critical Habitat (Corps Requirement) Sa. Will this project occur in or near an area with federally protected species or habitat?* r Yes r No 5b. Have you checked with the USFWS concerning Endangered Species Act impacts?* r Yes r No 5d. Is another Federal agency involved?* r Yes r No r Unknown 5e. Is this a DOT project located within Division's 1-8? r Yes r No 5f. Will you cut anytrees in order to conduct the work in waters of the U.S.? r Yes r No fig. Does this project involve bridge maintenance or removal? r Yes r No 5h. Does this project involve the construction/installation of a wind turbine(s)?* r Yes r No Si. Does this project involve (1) blasting, and/or (2) other percussive activities that will be conducted by machines, such as jackhammers, mechanized pile drivers, etc.? r Yes r No 5j. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? NC Natural Heritage Consultation Documentation Upload project _report _rollingwood_lots_93_95_ 18683_18683.pdf 983.86KB 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as an Essential Fish Habitat?* r Yes r No 6b. What data sources did you use to determine whether your site would impact an Essential Fish Habitat?* NOAA Habitat Conservation Essential Fish Habitat Mapper 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation status?* r Yes r No 7b. What data sources did you use to determine whether your site would impact historic or archeological resources?* NC Cultural Resources 7c. Historic or Prehistoric Information Upload 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA -designated 100 -year floodplain?* r Yes r No 8c. What source(s) did you use to make the floodplain determination?* FEMA maps from the link you provided Miscellaneous Comments This is for a Riparian Buffer authorization, no permits required. Miscellaneous attachments not previously requested. Signature W By checking the box and signing below, I certify that: . I have given true, accurate, and complete information on this form; • I agree that submission of this PCN form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); . I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act'); • I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND . I intend to electronically sign and submit the PCN form. Full Name: Wyatt L Brown Signature Date 5/27/2019 5/26/2019 The National Map - Advanced Viewer https://viewer.nationalmap.gov/advanced-viewer/1/1 USGS The National Map: Nati 600ft600ft600ft600ft600ft -78.439 35.657 Degrees + – Scale: 1:9,028 Zoom Level: 16 Help Data Download Services Find address or place * * * DISCLAIMER * * * Johnston County assumes no legal responsibility for the information represented here. Scale: 1:2466 - 1 in. = 205.49 feet (The scale is only accurate when printed landscape on a 8 1/2 x 11 size sheet with no page scaling.) Johnston County GIS May 26, 2019 Powered by TCPDF (www.tcpdf.org) 250 240 X w 230 220 Li) Li) n N 0+00 \ - 0 w ?< - '( " N Li) n N 0+10 pprox1male . ----::.,....--- 1u~...i1u1 --~ .. \ i-----,,...,,,--~ \ ....----,,...,,,-- \ _,/ V ,,...,,,--Approximate y ,,...,,,--rroposeu v raue " __.,- I ~ _,,,-v ~ ,/ v" / --I --------I " V "" /\ / .,..,...ILCA" ~·~- " / ~--' .. . -AT 0.50 SLO t>£ "" / BURY INVERT ONE FOOT ' , rUh H '/ll., Litt. , i--. .... ,e '-..../ PLACE CLAS~ B RIP RAP IN THE STREA, BED -'··-,--IA .. , "Tl•--• -----· r-1 -·--. .. , (SO IT IS FL ISH WITH THE BOTTOM OF T1 E CHANNEL) AND ALSO LI ,E THE STREA, BANKS FOR DISTANCE ......... ',.... ..... , ,.... . . -. . . N 0 Li) 0 Li) CX) st CX) ~ 0 n a, ~ n Li) <D n n n n st st st st N co N N N N N N N 0+20 0+30 0+40 0+50 0+60 0+70 0+80 0+90 LOT 9 5 DR I VE WAY ST A O + 0 0 THRU STA 1+00 PROFILE SCALE: 1" SCALE: 1" 5' (H) 1 O' (V) 250 ~ 240 230 220 0 CX) st N 1+00 240 <al X w 230 220 0 <D n N 0+00 I I / 0.. w X w r--.. Li) n N 0+10 :::::..- LENGTH OF PIPE SHOWN IS MINIMUM. BUILDER MAY INCREASE THE LENGTH IF NECESSARY WITH PRIOR APPROVAL FROM ENGINEER. MIN 3' SHOULDER FOR DRIVEWAY STABILITY FILL SLOPES TO BE STABILIZED WITH VEGETA TIDN AND /DR RIP RAP AS NECESSARY 12' WIDTH I .----:z::-:::=:::=~::::::==::::::::::::=~--'--, 2 1 1/2 TO 2 FT OF COVER TYPICAL DRIVEWAY SECTION OVER PIPE SUMMARY OF IMPACTS \11 ZONE 1 RIPARIAN BUFFER LOT 93 1,961.7 SF LOT 95 1,309.4 SF TOTAL 3,271.1 SF ZONE 2 RIPARIAN BUFFER LOT 93 660.2 SF LOT 95 652.6 SF TOTAL 1,312.8 SF STREAM IMPACTS 56 LF FROM CULVERT \ I t I \ I (RIP RAP SHALL BE PLACED FLUSH WITH THE BOTTOM OF THE CHANNEL) GENERAL NOTES 1. EXISTING SITE SURVEY INFORMATION WAS TAKEN FROM TOPOGRAPHIC SURVEY PROVIDED BY TRUE LINE SURVEYING, INC AND JOHNSTON COUNTY GIS. THESE PLANS DO NOT ASSUME ANY LIABILITY FOR ANY EXISTING INFORMATION, SHOWN OR NOT SHOWN, ON THE SURVEY AND ANY CHANGES TO THE EXISTING CONDITIONS THAT MAY HAVE OCCURRED AFTER THE SURVEY WAS ISSUED. CONTRACTOR SHALL VERIFY ALL EXISTING SITE CONDITIONS PRIOR TO CONSTRUCTION. 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE TYPE, SIZE, DEPTH, MATERIAL, AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. NOTIFY THE OWNER IMMEDIATELY IF UNKNOWN ELEMENTS ARE DISCOVERED THAT WOULD NECESSITATE MODIFICATION TO DESIGN. 3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS. Approximc te - r1 Vt-,.IVU\.,U ~ ~....Jt;\ ------~---~ 240 ----- ---------- ~ \ -:::::-.... \ ~ ---' -~ ' Approximate ' / Natural Grou nd "-V V ' f \ / " / 28 LF 54-IN PIPE '\ V Al U.c U ::,LU/-'c:. r--,' I ~;;~ •"' ~~·y;-t;.. '!f:±-1;:. ,;.,c, UI '--../ ----.. --......... --~ ~ .. -. . ---. ----... ..... . . NO HI 'HER THAN TH, EXISTING BEi ELEVATION (,SC2, IT IS FLUSH WIT THE BOTTOM OF THE CHAN ~ff) --J ,_ -·-' J l""'I " .. ' --,I"\ A ---• " -·-''-' -·-'' , .... '" ·-.. " ' -I 1 --I -- OF 30 LF FROM £AC ; OUTLET. 0 CX) 0 Li) CX) 0 0 Li) Li) N r--.. CX) ~ st Li) <D n n N N n n n n N co N N N N N N N 0+20 0+30 0+40 0+50 0+60 0+70 0+80 0+90 LOT 93 DRIVEWAY STA o+oo THRU STA 1+00 PROFILE SCALE: 1" SCALE: 1" so' (H) 1 O' ( V) 230 220 0 CX) n N 1+00 ~ .. • e: "' N "' -.. r-.. -E tl.l No 0 (,,)., 0 ~ >-:;?: I i..: ,C NL :3::: • ~ (,) "' ,: ~ er:~-@ ~ O> ~ <=~mg. Li..l I .._q:i • ~ >-L.iJ.s ~ ...:,::§2:i ooo·- ffi ~~ l~ ...:I SEALS REVISIONS ~ ~ 00 ~ ~ 0 " ~ ~~ 00 ~~ 0'1) ~o 00\ ~~ ~u ~~ ~~ 0~ ~ 00 ~00 ~~ 0~ ~s ~~ IIBVIIIWl!D BY: Lilli DIBSDIBDBY; Lilli DRAWHBY: Lilli DA1B: PBB20lf PIOlllCT '.NUMBIII: 1710 PLAN ANDPROFILB RIPARIAN BUFFER. IMPACT LOTS 93 & !IS DRIVBWAYS DWR-1 250 240 X w 230 220 Li) Li) n N 0+00 \ - 0 w ?< - '( " N Li) n N 0+10 pprox1male . ----::.,....--- 1u~...i1u1 --~ .. \ i-----,,...,,,--~ \ ....----,,...,,,-- \ _,/ V ,,...,,,--Approximate y ,,...,,,--rroposeu v raue " __.,- I ~ _,,,-v ~ ,/ v" / --I --------I " V "" /\ / .,..,...ILCA" ~·~- " / ~--' .. . -AT 0.50 SLO t>£ "" / BURY INVERT ONE FOOT ' , rUh H '/ll., Litt. , i--. .... ,e '-..../ PLACE CLAS~ B RIP RAP IN THE STREA, BED -'··-,--IA .. , "Tl•--• -----· r-1 -·--. .. , (SO IT IS FL ISH WITH THE BOTTOM OF T1 E CHANNEL) AND ALSO LI ,E THE STREA, BANKS FOR DISTANCE ......... ',.... ..... , ,.... . . -. . . N 0 Li) 0 Li) CX) st CX) ~ 0 n a, ~ n Li) <D n n n n st st st st N co N N N N N N N 0+20 0+30 0+40 0+50 0+60 0+70 0+80 0+90 LOT 9 5 DR I VE WAY ST A O + 0 0 THRU STA 1+00 PROFILE SCALE: 1" SCALE: 1" 5' (H) 1 O' (V) 250 ~ 240 230 220 0 CX) st N 1+00 240 <al X w 230 220 0 <D n N 0+00 I I / 0.. w X w r--.. Li) n N 0+10 :::::..- LENGTH OF PIPE SHOWN IS MINIMUM. BUILDER MAY INCREASE THE LENGTH IF NECESSARY WITH PRIOR APPROVAL FROM ENGINEER. MIN 3' SHOULDER FOR DRIVEWAY STABILITY FILL SLOPES TO BE STABILIZED WITH VEGETA TIDN AND /DR RIP RAP AS NECESSARY 12' WIDTH I .----:z::-:::=:::=~::::::==::::::::::::=~--'--, 2 1 1/2 TO 2 FT OF COVER TYPICAL DRIVEWAY SECTION OVER PIPE SUMMARY OF IMPACTS \11 ZONE 1 RIPARIAN BUFFER LOT 93 1,961.7 SF LOT 95 1,309.4 SF TOTAL 3,271.1 SF ZONE 2 RIPARIAN BUFFER LOT 93 660.2 SF LOT 95 652.6 SF TOTAL 1,312.8 SF STREAM IMPACTS 56 LF FROM CULVERT \ I t I \ I (RIP RAP SHALL BE PLACED FLUSH WITH THE BOTTOM OF THE CHANNEL) GENERAL NOTES 1. EXISTING SITE SURVEY INFORMATION WAS TAKEN FROM TOPOGRAPHIC SURVEY PROVIDED BY TRUE LINE SURVEYING, INC AND JOHNSTON COUNTY GIS. THESE PLANS DO NOT ASSUME ANY LIABILITY FOR ANY EXISTING INFORMATION, SHOWN OR NOT SHOWN, ON THE SURVEY AND ANY CHANGES TO THE EXISTING CONDITIONS THAT MAY HAVE OCCURRED AFTER THE SURVEY WAS ISSUED. CONTRACTOR SHALL VERIFY ALL EXISTING SITE CONDITIONS PRIOR TO CONSTRUCTION. 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE TYPE, SIZE, DEPTH, MATERIAL, AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. NOTIFY THE OWNER IMMEDIATELY IF UNKNOWN ELEMENTS ARE DISCOVERED THAT WOULD NECESSITATE MODIFICATION TO DESIGN. 3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS. Approximc te - r1 Vt-,.IVU\.,U ~ ~....Jt;\ ------~---~ 240 ----- ---------- ~ \ -:::::-.... \ ~ ---' -~ ' Approximate ' / Natural Grou nd "-V V ' f \ / " / 28 LF 54-IN PIPE '\ V Al U.c U ::,LU/-'c:. r--,' I ~;;~ •"' ~~·y;-t;.. '!f:±-1;:. ,;.,c, UI '--../ ----.. --......... --~ ~ .. -. . ---. ----... ..... . . NO HI 'HER THAN TH, EXISTING BEi ELEVATION (,SC2, IT IS FLUSH WIT THE BOTTOM OF THE CHAN ~ff) --J ,_ -·-' J l""'I " .. ' --,I"\ A ---• " -·-''-' -·-'' , .... '" ·-.. " ' -I 1 --I -- OF 30 LF FROM £AC ; OUTLET. 0 CX) 0 Li) CX) 0 0 Li) Li) N r--.. CX) ~ st Li) <D n n N N n n n n N co N N N N N N N 0+20 0+30 0+40 0+50 0+60 0+70 0+80 0+90 LOT 93 DRIVEWAY STA o+oo THRU STA 1+00 PROFILE SCALE: 1" SCALE: 1" so' (H) 1 O' ( V) 230 220 0 CX) n N 1+00 ~ .. • e: "' N "' -.. r-.. -E tl.l No 0 (,,)., 0 ~ >-:;?: I i..: ,C NL :3::: • ~ (,) "' ,: ~ er:~-@ ~ O> ~ <=~mg. Li..l I .._q:i • ~ >-L.iJ.s ~ ...:,::§2:i ooo·- ffi ~~ l~ ...:I SEALS REVISIONS ~ ~ 00 ~ ~ 0 " ~ ~~ 00 ~~ 0'1) ~o 00\ ~~ ~u ~~ ~~ 0~ ~ 00 ~00 ~~ 0~ ~s ~~ IIBVIIIWl!D BY: Lilli DIBSDIBDBY; Lilli DRAWHBY: Lilli DA1B: PBB20lf PIOlllCT '.NUMBIII: 1710 PLAN ANDPROFILB RIPARIAN BUFFER. IMPACT LOTS 93 & !IS DRIVBWAYS DWR-1 ■ ■■■ Roy Cooper. Governor ME NC DEPARTMENT OF Susi Hamilton, Secretary women NATURAL AND CULTURAL RESOURCES 0 son Walter Clark, director, Land and Water Stewardship NCNHDE-9077 May 26, 2019 wyatt brown Brown's Environmental Group, inc 242 Batten Farm Road Selma, NC 27576 RE. Rollingwood, lots 93, 95 Dear wyatt brown. The North Carolina Natural Heritage Program (NCNHP) appreciates the opportunity to provide information about natural heritage resources for the project referenced above. Based on the project area mapped with your request, a query of the NCNHP database indicates that there are no records for rare species, important natural communities, natural areas, and/or conservation/managed areas within the proposed project boundary. Please note that although there may be no documentation of natural heritage elements within the project boundary, it does not imply or confirm their absence, the area may not have been surveyed. The results of this query should not be substituted for field surveys where suitable habitat exists. In the event that rare species are found within the project area, please contact the NCNHP so that we may update our records. The attached `Potential Occurrences' table summarizes rare species and natural communities that have been documented within a one -mile radius of the property boundary. The proximity of these records suggests that these natural heritage elements may potentially be present in the project area if suitable habitat exists. Tables of natural areas and conservation/managed areas within a one -mile radius of the project area, if any, are also included in this report. If a Federally -listed species is found within the project area or is indicated within a one -mile radius of the project area, the NCNHP recommends contacting the US Fish and Wildlife Service (USFWS) for guidance. Contact information for USFWS offices in North Carolina is found here: httr)s://www.fws.gov/offices/Directory/ListOffices.cfm?statecode=37. Please note that natural heritage element data are maintained for the purposes of conservation planning, project review, and scientific research, and are not intended for use as the primary criteria for regulatory decisions. Information provided by the NCNHP database may not be published without prior written notification to the NCNHP, and the NCNHP must be credited as an information source in these publications. Maps of NCNHP data may not be redistributed without permission. The NC Natural Heritage Program may follow this letter with additional correspondence if a Dedicated Nature Preserve, Registered Heritage Area, Clean Water Management Trust Fund easement, or Federally -listed species are documented near the project area. If you have questions regarding the information provided in this letter or need additional assistance, please contact Rodney A. Butler at rod nev.butlerWncdcr.gov or 919-707-8603. Sincerely, NC Natural Heritage Program DEPAR71MENT OF NATURAL AND CULTURAL RESOVRCES Q 121 W. JON E5 STREET. RALEIGH. NC 77603 • 1651 MAIL SERVICE CENTER. RALEIGH. NC 77699 OFC 919.707.9120 • FAX 919.707.9121 Natural Heritage Element Occurrences, Natural Areas, and Managed Areas Within a One -mile Radius of the Project Area Rollingwood, lots 93, 95 May 26, 2019 NCNHDE-9077 Element Occurrences Documented Within a One -mile Radius of the Project Area Taxonomic EO ID Scientific NameCommon NameM Last 'MW Element Accuracy Federal State Global State Group 0servation Occurrence Status tatus Rank Rank A Date = Rank Dragonfly or 33753 Somatochlora Coppery Emerald 2004 -Pre H? 5 -Very --- Significantly G3G4 S2? Damselfly georgiana Low Rare No Natural Areas are Documented Within a One -mile Radius of the Project Area Managed Areas Documented Within a One -mile Radius of the Project Area Managed Area Name wner 110P Owner Type Johnston County Open Space Johnston County. multiple local Local Government government Definitions and an explanation of status designations and codes can be found at httr)s:Z/ncnhde.natureserve.org/content/helr). Data query generated on May 26, 2019; source: NCNHP, Q2 Apr 2019. Please resubmit your information request if more than one year elapses before project initiation as new information is continually added to the NCNHP database. Page 2 of 3 NCNHDE-9077: Rollingwood, lots 93, 95 - _ CII \ � 17 0a\bea � � F � n , � rn c o B --- -- - - - - -- Oakdale Ave S, \ kk 358 h LL 2.O P3 1 I 5 \ Sid 6a 'iy ,9 c ♦ �.� q �c S Pmeland Ave i P` �. y ♦ � Si :�o � S6� f flood Ave h� �r of �aS aoo\ lS _ Qn`oo N 70'°rC Randolph') Camel St 61. Q �'S cF Q-� 5 Odd, .;, ,. -�• Clayton, Fox p� aW Clayton 'eldsPar \.�ood� 0 c' a\ama � N cep\ta\5 0.ar1'park Or IG w Mage ood h OA v laic cemiaN [1 Bea S C• L ` I \ ~ s May 26, 2019 Project Boundary Buffered Project Boundary Managed Area (MAREA) Page 3 of 3 NG 47" 1:20,649 0 0.175 0.35 0.7 mi 0 0.275 0.55 1.1 km SourcesEsri, HERE, Garmin, Intermap, increment P Corp-, GEBCO, USGS, ENO, NPS, NRCAN, GeoBase, IGN, Kadaster NL, Ordnance Survey, Esri Japan, METI, Esri China (Hong Kong), (c) OpenStreetMap contributors, and the GIS User Community