Loading...
HomeMy WebLinkAboutNC0039420_NC0039420_20190422I ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Director Mr. Allen Campbell Special Facilities Program Manager Virginia Department of Transportation 1401 East Broad Street Richmond, VA 23219 NORTH CAROLINA Environmental Quality April 22, 2019 SUBJECT: Compliance Evaluation Inspection VA DOT 1-77 Rest Area WWTP NPDES Permit No. NCO039420 Surry County Dear Mr. Campbell: On April 9, 2019, Gary Hudson of this office met with Chris Marion, ORC, to perform a Compliance Evaluation Inspection on the VADOT 1-77 Rest Area wastewater treatment system. This type of inspection consists of two basic parts: an in -office file review and an on -site inspection of the treatment facility. The attached EPA inspection form notes the eight (8) areas that were evaluated for this inspection. The findings and observations are outlined below: I. Permit The facility appeared to be as described in the permit. The current permit has expired. An application for renewal has been submitted. II. Self -Monitoring Program A review of the monthly self -monitoring reports (DMR's) for the period January 2018 through December 2018 showed that the facility was in complete compliance with all final NPDES effluent limits for the period. III. Flow Measurement The permit requires continuous flow recording. Flow is measured by a Siemens Millitronics OCM III meter. This meter was calibrated last by Delta Environmental on 3-14-19. IV. Sludge Handling and Disposal Solids are removed as necessary by a licensed VA hauler for disposal in the nearest POTW. -- - 15 1H D_E North Carolina Department of Environmental Quality 1 Division of Water Resources Winston-Salem Regional Office 1 450 Hanes Mill Road. Suite 300 1 Winston-Salem, North Carolina 27105 336.776.9800 r V. Operations and Maintenance No problems were observed during the time of the inspection. The plant appears to be well maintained and operated. VI. Facility Site Review The 0.020 MGD facility consists of the following: bar screen and comminutor, aerated equalization basin, sodium hydroxide feed for pH adjustment, flow splitter box, three aeration basins, three secondary clarifiers, three sludge holding basins, and a new LIV disinfection system. VII. Records/Reports A daily visitation log is kept on site and was available for inspection. The records were thorough and complete. Vill. Effluent/Receiving Waters The system discharges into Naked Run, Class "WS-IV" trout waters. The effluent was clear on the date of the inspection. We feel that Mr. Marion is doing an excellentjob in operating and maintaining this treatment facility. Should you have any questions concerning this report, please contact Gary Hudson or me at (336) 776-9800. Sincerely, Docu3lpnM by: 74M49E225C94EA... Lon Snider Assistant Regional Supervisor Water Quality Regional Operations Division of Water Resources cc: NPDES Central Files WSRO United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NCO039420 I11 12 19/04/09 17 18 I � j 19.1 G I 201 211 1 1 1 I I I I I I 11 I 1 I I I I I I I I I I I I I I I I I I I I I I I I l i I -I 166 I Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 67 70 I I 71 L I 72 1, J 731 I 174 75I I I I •I I I I80 LI I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 03:30PM 19/04/09 19/03/01 Virginia DOT/1-77 Rest Area. Exit Time/Date' Permit Expiration Date 1-77 NC-Va State Line Car Pine Hall NC 27042 04:30PM 19/04/09 24/02/28 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Christopher S Marion/ORC/336-786-3597/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Allen Campbell,1401 E Broad St Richmond VA 23219//804-786-0668/8047860652' No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit .0 Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program E Sludge Handling Disposal Facility Site Review Efnuent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Division of Water Quality//336-776-9694i Gary Hudds�o�n/{ / J j cugned by: Agency/Office/Phone and Fax Numbers Date Signature of Management Q A Review[�_":'T''25C94EA 4/22/2019 ... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type 3I : NCo039420 I11 12 1 s/oa/os 17 18 1 ,. Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# Permit: NCO039420 Owner - Facility:. Virginia DOT/1-77 Rest Area Inspection Date: 04/09/2019 Inspection Type: Compliance Evaluation Operations $ Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? M ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable 0 ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Record Keeping Yes No NA NE Are records kept*and maintained as required by the permit? M ❑ ❑ ❑ Is all required information readily available, complete and current? M ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? M ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? M ❑ ❑ ❑ Is the chain -,of -custody complete? M ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? 0 ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? M ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ M ❑ on each shift? Is the ORC visitation log available and current? M ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? M ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? 0 ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? 0 ❑ ❑ ❑ Comment: _ Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical ❑ Are the bars adequately screening debris? 0 ❑ ❑ ❑ Is the screen free of excessive debris? 0 ❑ ❑ ❑ Page# 3 j Permit: NCO039420 Owner - Faciliity: Virginia DOT/1-77 Rest Area Inspection Date: 04/09/2019 Inspection Type: Compliance Evaluation Bar Screens Yes No NA NE Is disposal of screening in compliance?. N ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: ^ Equalization Basins Yes No NA NE Is the basin aerated? S ❑ ❑ ❑. Is the basin free of bypass lines or structures to the natural environment? N ❑ ❑ ❑ Is the basin free of excessive grease? N ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? M ❑ ❑ ❑ Are float controls operable? 0 ❑ ❑. ❑ Are audible and visual alarms operable? �,. ❑ ❑ ❑ # Is basin size/volume adequate? ❑ ❑ ❑ Comment: Aeration Basins Yes No NA NE Mode of operation Ext..Air Type of aeration system Diffused Is the basin free of dead spots? E ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ E, ❑ Are the diffusers operational? 0 ❑ ❑ ❑ Is the foam the proper color for the treatment process? E ❑ ❑ ❑ - Does the foam cover less than 25% of the basin's surface? S ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) ❑ `.❑ ❑ Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ❑ ❑ 0 ❑ Are weirs level?. ❑ ❑ ❑ Is the site free of weir blockage? N ❑ ❑ ❑ Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ Page# 4 Permit: NC0039420 Owner - Facility: Virginia DOT/1-77 Rest Area Inspection Date: 04/09/2019 Inspection Type: Compliance Evaluation Secondary Clarifier Yes No NA NE Is scum removal adequate? ❑ ❑ 0 Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? ❑ ❑ 0 ❑ Is the return rate acceptable (low turbulence)? M ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? M ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately %4 of the sidewall depth) ❑ ❑ ❑ Comment: - Aerobic Digester Yes No NA NE Is the capacity adequate? 0 ❑ ❑ ❑ Is the mixing adequate? M. ❑ ❑ ❑ Is the site free of excessive foaming in the tank? 0 ❑ ❑ ❑ # Is the odor acceptable? M ❑ ❑ ❑ # Is tankage available for properly waste sludge? M ❑ ❑ ❑ Comment: Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? 0 ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ ❑ Number of tubes in use? 3 Is the level of chlorine residual acceptable? 0 ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? 0 ❑ ❑ ❑ Comment: - Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? ❑ ❑ ❑ Are UV bulbs clean? 0 ❑ ❑ ❑ Is UV intensity adequate? ❑ ❑ ❑ Is transmittance -at or above designed level? M ❑ ❑ ❑ Is there a backup system on site? M ❑ ❑ ❑ Is effluent clear and free of solids? 0 ❑ ❑ ❑ Comment: - Page# 5 i' 4 Permit: NC0039420 Owner - Facility: Virginia DOT/1-77 Rest Area Inspection Date: 04/09/2019 Inspection Type: Compliance Evaluation De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? 0 ❑ ❑ ❑ Is storage appropriate for cylinders? ❑ ❑ M ❑ # Is de -chlorination substance stored away from chlorine containers? M ❑ ❑ ❑ Comment: Are the tablets the proper size and type? 0 ❑ ❑ ❑ Are tablet de -chlorinators operational? M ❑ ❑ ❑ Number of tubes in use? 3 Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? M ❑ ❑ ❑ Is flow meter calibrated annually? 0 .❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑, (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 ❑ ❑ ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: Page# 6