HomeMy WebLinkAboutLongs Chapel United Methodist Church - Wet Pond SupplementalFORMS LOADED .OJECT INFORMATION 1 Project Name Longs Chapel United Methodist Church 2 Project Area ac 5.48 3 Coastal Welland Area ac 0 4 Surface Water Area ac 0 5 its this project Hi h or Low Density? High 6 Does this project use an off -site SCM? No IMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided feet 30 8 Will the vegetated setback remain vegetated? Yes 9 Is BUA other that as listed in .1003 4 o-d out of the setback? Yes 0 Is streambank stabilization proposed on this project? No IMBER AND TYPE.OF SCMs: 1 Infiltration 0 2 -System Btoretention Cell 0 3 Wet Pond 1 4 Stormwater Wetland 0 5 Permeable Pavement 0 6 Sand Filter 0 7 Rainwater Harvesting RWH 0 8 Green Roof 0 9 Level 5 reader-Fliter Strip LS-FS 0 !0 Disconnected Impervious Surface (DIS) 0 11 Treatment Swale 0 2 Dry Pond 0 !3 StormFitter 0 A Silva Cell 0 'S 13ayf niter 0 '8 Filters J 0 FORMS LOADED :SIGNER CERTIFICATION 7 Name and Title: R. Daniel Hatt, PLA, ASLA !8 Organization: WadeTrim lnc. !9 Street address: 53 N. Market Street, Suite 200 10 City, State, Zip: Asheville, NC 28801 11 Phone numbers : 828-712-3916 12 Email: rhyatt@wadetdm.com Certification Statement: I certify, under penalty of law that this Supplement-FZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. i111111 pfr""I -, 'O lu * No. 1405 n� SI 10 Mir Dale +s wrin■ Mr1vr rlI V 1 Is this a hi h densi project? Yes 2 If so number of drainage areaslSCIVIs 1 3 Is all/part of this project subject to previous rule versions? No FORMS LOADED WNAGE AREA INFORMATION Entire Site 1 4 Type of SCM Wet Pond 5 Total BUA in project (sq ft 152024 sf 6 New BUA on subdivided lots (subject to permill€ng) M 0) 152024 sf 7permitting) New BUA outside of subdivided lots (subject to s sf B Offsite -total area s9 ft) _ sf 9 0 _ - _ Offsite BUA (soft)_ _ _ Breakdown of new BUA outside subdivided lots: sf Parkin s fl Sidewalk (sq ft - Roof (sq ft Roadway sq ft Future (sq ft - Other, please specify in the comment box below (sq ft 1 New infiltrating permeable pavement an subdivided lots (sq ft sf 2 New Infiltrating permeable pavement outside of subdivided lots (sq ft sf 3permitting) Exisitng BUA that will remain (not subject to s fl sf 4 Existing BUA that is alreaqy.permitted C ft sf 5 Existing BUA that will be removed s ft sf 6 Percent BUA 64% 7 IDesian storm inched --. 1 in S IDesicin volume of SCM cu 01 16916 9 Calculallon method for dest n volume SAID ca )DlTIONAL INFORMATION 0 Please use this space to provide any additional information about the dralnage area(s): VET POND 1 Drainage area number 1 2 design volume of SCM (cu fl) 16916 of YFRAI MAC FROM 0214.10S0 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM (H:V)? 2:1 6 Does the SCM have retaining walls, gabiion walls or other engineered side slopes? No 7 Are the inlets, outlets, and receiving stream protected from erosion (10-year storm)? Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes 9 What is the method for dewatering the SCM for maintenance? Pump (preferred) 10 If applicable, will the SCM be leaned out after construction? Yes 11 Does the maintenance access comply with General MDC (8)? Yes 12 Does the drainage easement comply with General MDC (9)? Yes 13 If the SCM is on a single family lot, does (witl?) the plat comply with General MDC (10)? Yes 14 Is there an O&M Agreement that complies with General MDC (11)? Yes 15 Is there an O&M Ian that complies with General MDC (12)? Yes 161 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? Yes -T POrin MnC FROM n2H _1053 18 Method used SA1DA 19 Has a stage/storage table been provided in the calculations? Yes 20 Elevation of the excavated main pool depth (bottom of sediment removal) (fmsl) 2557.00 21 Elevation of the main pool bottom -(tap of sediment removal) (fmsl) 2557.50 22 Elevation of the bottom of the vegetated shelf (fmsl) 2561.00 23 Elevation of the permanent pool (fmsl) 2561.00 24 Elevation of the top of the vegetated shelf (fmsl) 2562.00 25 Elevation of the temporary pool (fmsl) 2562.50 26 Surface area of the main permanent pool (square feet) 5207:1 27 Volume of the main permanent pool (cubic feet) 16916 of 28 Average depth of the main pool (feet) 4.00 ft 29 Average depth equation used Equation 2 30 If using equation 3, main pool perimeter (feet) 31 If using equation 3, width of submerged veg. shelf (feel) 32 Volume of the forebay (cubic feet) 6106 of 33 Is this 15-201/6 of the volume in the main pool? Yes 34 _ C€ean-out depth for forebay (inches) 6 in 35 Design volume of SCM (cu ft) 16916 of 36 Is the outlet an orifice of a weir? Orifice 37 If orifice, orifice diameter (inches) 3 in 38 tf weir, weir height (inches) 39 If weir, weir length (inches) 40 Drawdown time for the temporary pool (days) 2 41 Are the inlet(s) and outlet located in a manner that avoids short- circuiting? Yes 42 Are berms or baffles provided to improve the flow path? No 43 Depth of forebay at entrance (inches) 42 in 44 Depth of forebay at exit (inches) 36 in 45 Does water flow out of the forebay in a non -erosive manner? Yes 46 Width of the vegetated shelf (feet) 6 ft 47 Slope of vegetated shelf (H:V) 6:1 48 Does the orifice drawdown from below the top surface of the permanent pool? No 49 Does the pond minimize impacts to the receiving channel from the 1- yr, 24-hr storm? Yes 50 Are fountains proposed? (If Y, please provide documentation that MDC(9) is met.) No 51 Is a trash rack or other device provided to protect the outlet system? Yes 52 Are the dam and embankment planted in non -clumping turf grass? Yes 53 Species of lurfthat will be used on the dam and embankment Turf Type Fescue 54 Has a planting plan been provided or the vegetated shelf? Yes DITIONAL INFORMATION 55 Please use this space to provide any additional information about the wet pond(s):