Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
820465_CORRESPONDENCE_20171231
CORRESPONDENCE NORTH CAROLINA Department of Environmental Qual •f' II Carroll's Foods, Inc. c/o David Nordin PO Box 856 Warsaw, NC 28398 NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES SUBJECT: Operation Review Notice of Referral Farm 2539 Facility No. 82-465 Sampson County Dear Mr. Nordin, FAYE`ITEVILLE REGIONAL OF'F'ICE February 24, 1999 On February 17, an Operation Review was conducted on Farm 2539, facility no. 82-465. This Review, undertaken in accordance with G.S. 143-215.1 OD, is ane of two visits scheduled for all registered livestock operations during the 1999 calendar year. The Division of Water Quality will conduct a second site inspection. During the Review, it was noted that the liner is not properly installed on the new lagoon on the side closest to the big lagoon. The clay liner underneath the plastic was severely eroded. You need to contact your technical specialist in regards to the liner not F installed. It was also noted that the permit for the new system being tested on the big lagoon is not addressed under the permit issued for the farm site. Your technical specialist needs to contact Division of Water Quality in regards to the permit for the new system. You are strongly encouraged to contact your certified technical specialist for help. You may also want to contact your local Soil and' Water Conservation District Office since they may be able to provide you with additional technical and/or financial assistance to implement corrective best management practices. Please remember that in order for your facility to be in compliance with environmental regulations, animal waste cannot be discharged into the waters of the State, and the animal waste collection, treat, storage and disposal systems must be properly sized, maintained and operated under the responsible charge of certified operator. The Division of Soil and Water Conservation appreciatesyour cooperation with this Operation Review. Please do not hesitate to call me at 910/486-1541 extension 292 if you have any questions, concerns or need additional information, icre , f� Scott Faircloth Environmental Specialist II cc: DWQ-Fayetteville Regional Office DSWC Regional Files Sampson County SWCD 225 GREEN STREET, SUITE 714, FAYETTEWLLE, NORTH CAROLINA 28301 •5043 PHONE 810-488.1541 FAX 810-486.0707 AN EQUAL OPPORTUNITY /AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLED/10% P08T-C0NSUMER PAPER &N f; andWate` Cor ne,. s<e:rrv: a, :tio, n «; IOpere'tion Reyie! vvj� �• I,@ kit I k i ! 1 ,i I .k.. ,kli`<iNkt<',:riffr II�Y.'.[!I ��.I I�I,;� „f II: �I II P ,I " �(] Dvis�an!`sol vt Soil and .Water Conservation i 'Com liancel'Ins ectiort I. �r':„ ;i'^'k9 I,. p :�� Divisiairof�Watcr Quality Compliance Inspection�;,� f,�i :k ��i,. ,;IR I�j, !� k�..k;, - i t �1� 11 r "i ,. t .Other Agency Operation Review�' , , a k tk t ,ofd' l{ ' r �; .� i�G !a' ' jl r,� ii h �� ±""� ! ` � 1ii��, �o k k. ,,. l! fH•k:1i 10 Routine O Complaint O Follow-up of DWQ inspection O Follow-up of DSWC review O Other Facility Number 82 465 Date of Inspection 2-17-99 Time of Inspection 14:15 24 hr. (hh:mm) ® Permitted ® Certified 0 Conditionally Certified © Registered JQ Not Opera Date Last Operated: .... FarmName: 25.359 .................................................................................................................... County: 5.9wP50-U ........................................... ERO ............. OwnerName: ................................................... ............................... Phone No: 910.-2.93:73.43.4 ........................................................... Facility Contact: 11 ichae.1.Graixain......................................... Title: Employer.................................... ... Phone No: 291-3,43.4-1 ...... I ...... MailingAddress: !t?...l3ct f........................................................................................... 1'.l'.alrsAff..N.0....................... ................................... 2A390.............. Onsite Representative: 1.Yl dwet.Gxalt= .......................................... . Integrator:Cjarr.911'sF9u&T=............................................... Certified Opera tor:.Cjaylou,S.. ............................ Murphy............................................ Operator Certification Number:18725 Location of Farm: 5�..19.R1..1l�.anaie..fxuxrian�t�rx�tietx.Wlttt.,S.1.7..4.Q�.1..11.xnllsrs.a�xann.a�t.�kit�t.Q.tr S1t.1901�................................................................................ Laiitude • 6 46 Longitude • 6 66 Design Current Swine Capacity Population ❑ Wean to Feeder ❑ Feeder to Finish Farrow to Wean LJ Farrow to Feeder Farrow to Finish 1000 LJ i is Ej Boars f, I " Design Current Design urrent Poultry . Capacity Population ' Cattle Capacity;, Populatioq, ❑ Layer ❑ Dairy ❑ Non -Layer ❑ Non -Dairy ❑ Other I I Total Design Capacity. 1,000 —� Total SSLW 1,417,000 Number of Lagoons, ❑ Subsurface Drains Present I I[] Lagoon Area I0'Spray Field Area 1 1. , Holding Ponds 1 Solid Trap's ❑ No Liquid Waste Management System t. Discharees & Stream Impacts 1. Is any discharge observed from any part of the operation? ❑ Yes ® No Discharge originated at; ❑ Lagoon ❑ Spray Field ❑ Other a. If discharge is observed, was the conveyance man-made? ❑ Yes ® No b. If discharge is observed, did it reach Water of the State? (If yes, notify DWQ) ❑ Yes ® No c. If discharge is observed, what is the estimated flow in gaUmin? nla d. Does discharge bypass a lagoon system? (if yes, notify DWQ) ❑ Yes ® No 2. Is there evidence of past discharge from any part of the operation? ❑ Yes ® No 3. Were there any adverse impacts or potential adverse impacts to the Waters of the State other than from a discharge? ❑ Yes ® No Waste Collection & 'Treatment 4. Is storage capacity (freeboard plus storm storage) less than adequate? ❑ Spillway ❑ Yes ® No Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: 13ig..fag.Qoja .........Litklc.,l Ags)QIP............................ Freeboard (inches): " .. 5. Are there any immediate threats to the integrity of any of the structures observed? (ie/ trees, severe erosion, ❑ Yes ® No seepage, etc.) 116199 Continued on back Facii ty Number: 82-465 Date of Inspection 2-17-99 �1 6. Are there structures on-site which are not properly addressed and/or managed through a waste management or closure plan? ® Yes ❑ No (If any of questions 4-6 was answered yes, and the situation poses an immediate public health or environmental threat, notify DWQ) 7. Do any of the structures need maintenance/improvement? N Yes ❑ No 8. Does any part of the waste management system other than waste structures require maintenance/improvement? ❑ Yes ® No 9. Do any stuctures lack adequate, gauged markers with required maximum and minimum liquid level elevation markings? ® Yes ❑ No Waste Anulication 10. Are there any buffers that need maintenance/improvement? ❑ Yes ® No 11. Is there evidence of over application? ❑ Excessive Ponding ❑ PAN ❑ Yes ® No 12. Crop typeC.oastal.B�rmuda�.(�rxaze.}........... ....................... .............. .i d1. Yj-,gclab1ga.............. 13. Do the receiving crops differ with those designated in the Certified Animal Waste Management Plan (CAWMP)? ❑ Yes ® No 14. a) Does the facility lack adequate acreage for land application? ❑ Yes ❑ No b) Does the facility need a wettable acre determination? ® Yes ❑ No 15. Does the receiving crop need improvement? ❑ Yes ® No 16, is there a lack of adequate waste application equipment? ❑ Yes ® No Required .Records & Documents 17. Fail to have Certificate of Coverage & General Permit readily available? ❑ Yes ®No 18. Does the facility fail to have all components of the Certified Animal Waste Management Plan readily available? No:violations-4r. deficiencies.weire•noted,dtiring'this',visit: •You•iwillfeceive no furthe'r.': (ie/ WUP, checklists, design, maps, etc.) ® Yes ❑ No 19. Does record keeping need improvement? (ie/ irrigation, freeboard, waste analysis & soil sample reports) ® Yes ❑ No 20. Is facility not in compliance with any applicable setback criteria in effect at the time of design'? ❑ Yes ® No 21. Did the facility fail to have a actively certified operator in charge? ❑ Yes ® No 22. Fail to notify regional DWQ of emergency situations as required by General Permit? NOTE: Need to contact DWQ in regards to permit for new system being tested on big lagoon. Need to stay off drinking well 100 (ie/ discharge, freeboard problems, over application) ❑ Yes ® No 23. Did Reviewer/Inspector fail to discuss review/inspection with on-site representative? ❑ Yes ® No 24. Does facility require a follow-up visit by same agency? ❑ Yes ®No 25. Were any additional problems noted which cause noncompliance of the Certified AWMP? ❑ Yes ®No No:violations-4r. deficiencies.weire•noted,dtiring'this',visit: •You•iwillfeceive no furthe'r.': ... ...... correspondence about this visit:. ............ .... . Comments (refer to question#) Explain a'ny YES answers andlor any recomniendatiorm or any other` colmments' Use drawings' of facility to;better eiplam situations: (use additional page§ as necessary) , , H' !! `.I �' ! ! riM1 I}. A , I 1. !j. '.1 ..11!'+all i.�, ti��JR_I♦fl I I ..�.I.fl. ,� Ivleli I !.� r iw.l According to the database, Start Date 0 1/0 1/89 Certification hate 11/9/98 .► 6- On new lagoon (liner) is not properly installed on side closest to big lagoon. Clay liner underneath plastic severely eroded. Need to contact technical specialist in reguards to liner not properly installed. No waste going into lagoon. Need to repair depending on time frame stated by technical specialist. 7- Need to extend discharge pipes into big lagoon that are cut off and broke off as lagoon level is lowered. 9- No marker is present in new lagoon at time of review. NOTE: Need to contact DWQ in regards to permit for new system being tested on big lagoon. Need to stay off drinking well 100 feet when applying waste in spray field. Reviewer/Inspector Name tScott ' it ,�:11� 1I Reviewer/Inspector Signature: Date: 1/6/99 1\1 116199