Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
820114_Inspection_19990706
vmiw NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES FAYETTEVILLE REGIONAL OF'F'ICE July 06, 1999 Georgge Upton 1325Lisbon Street Clinton, NC 28328 SUBJECT: Operation Review Notice of Referral Williamson and Upton Hog Farm Facility No. 82-114 Sampson County Dear Mr. Upton, On June 23, an Operation Review was conducted on Williamson and Upton Hog Farm, facility no. 82-114. This Review, undertaken in accordance with G.S. 143-215.10D, is one of two visits scheduled for all registered livestock operations during the 1999 calendar year. The Division of Water quality will conduct a second site inspection. During the Review, it was noted that there was a wet area on the toe of the outside slope of the lagoon behind the pump house next to the woods line. The liquid in the wet area had a oxidized color (red -orange color). The Division of Water Qualitywill conduct a follow-up visit to the farm site to check for possible seepage problem of agoon. You are strongly encouraged to contact your certified technical specialist for help. You may also want to contact your local Soil and Water Conservation District Office since they may be able to provide you with additional technical and/or financial assistance to implement corrective best management practices. Please remember that in order for your facility to be in compliance with environmental regulations, animal waste carmot be discharged into the waters of the State, and the animal waste collection, treatment, storage and disposal systems must be properly sized, maintained and operated under the responsible charge of a certified operator. The Division of Soil and Water Conservation appreciates your cooperation with this Operation Review. Please do not hesitate to call me at 910/486-1541 extension 292 if you have any questions, concerns or need additional information. Si cer ly cott Faircloth Environmental Specialist cc: DWQ-Fayetteville Regional Office DSWC Regional Files Sampson County SWCD Ernest Smith f=arms .225 GREEN STREET, SUITE 714, FAYETTEVILLE, NORTH CAROLINA 28301-5043 PHONE 610.4a6-11 541 FAX 910.488-0707 AN EQUAL OPPORTUNITY /AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLED/10% POST -CONSUMER PAPER Facility Number 82 114 Date of Inspection 6-23-99 Time of Inspection 9:25 24 hr. (hh:mm) ® Permitted ® Certified © Conditionally Certified © Registered [3Not O erutional Date Last Operated: Farm Name: W..iUiAmsojt.,atzd..Upiu.U.Ho.g.F.arm...................................................... County: Sampaam........................................... F.RQ ............. OwnerName: George .................................... U.11t.Q11 .......................................................... Phone No: 9A:591:5574 ........................................................... Facility Contact: Geur99..UPLttm................................................Title: Qw..ur.................................................. Phone No:................................................... Mailing Address: 13.25.UsbmX.SL............................. Onsite Representative: Gcarl c.,Uptott,.A.llrcd.Sualtlt.............................................. Integrator: Erxl i.Sntithl.FoX. 5........................................... Certified Operator:.t,'ic.Rrgc.? ............................... Uplou ................................................ Operator Certification Number:1.8457.............................. Location of Farm: fa.ke.4�1..Sa>xt�..aa;.�li�atam�...l�a.,apFxa�imatte�y..&..mrile,�.ta.xaad.�.ll���.Luxrr..right.nn►.11.9.G.,end.g�v.ata�xoxxnaa!k�ly...l.�nil�h..:l:ux�t. ' .....r.r...... :t..l;dg�.,a .talrldn..kln ;Xt�.tases..a r.� ixnrax�l ; /.4..nnili�,.. Latitude 34 •52 36 �� Longitude 78 ' i6 34 Design Current Design Current Design Current Swine Capacity Population Poultry Capacity Population Cattle Capacity Population ❑ Wean to Feeder JE1 Layer I JE1 Dairy ® Feeder to Finish 7320 JE1 Non -Layer ❑ Non -Dairy Farrow to Wean Farrow to Feeder JE3 Other Farrow to Finish Total Design Capacity 7,320 (jilts Total SSLW 988,200 ju Boars. Number of Lagoons ❑ Subsurface Drains Presenti] Lagoon Area ❑ Spray Fleld Area Holding Ponds 1 Solid Traps ❑ No Liquid Waste Management System Discharges & Stream Impacts 1. Is any discharge observed from any part of the operation? ❑ Yes ® No Discharge originated at: ❑ Lagoon ❑ Spray Field ❑ Other a. If discharge is observed, was the conveyance man-made? ❑ Yes ® No b. if discharge is observed, did it reach Water of the State? (If yes, notify DWQ) ❑ Yes ® No c. If discharge is observed, what is the estimated flow in gal/min? n/a d. Does discharge bypass a lagoon system? (If yes, notify DWQ) ❑ Yes ® No 2. Is there evidence of past discharge from any part of the operation? ❑ Yes ® No 3. Were there any adverse impacts or potential adverse impacts to the Waters of the State other than from a discharge? ❑ Yes ® No Waste Collection & Treatment 4. Is storage capacity (freeboard plus storm storage) less than adequate? ❑ Spillway ❑ Yes ® No Structure I Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 ldentifrer:................................................................................................................................................ Freeboard (inches): ..............25:'. ............... .......................................................................................................................................................................... 5. Are there any immediate threats to the integrity of any of the structures observed? (ie/ trees, severe erosion, ❑ Yes ® No seepage, etc.) 3123199 Continued on buck Facility Number: 82-114 Date of Inspection 6-23-99 ' 6. Are there structures on-site which are not properly addressed and/or managed through a waste management or closure plan? ❑ Yes ® No (If any of questions 4-6 was answered yes, and the situation poses an immediate public health or environmental threat, notify DWQ) 7. Do any of the structures need maintenance/improvement? ® Yes ❑ No 8. Does any part of the waste management system other than waste structures require maintenance/improvement? ❑ Yes ®No 9. Do any stuctures lack adequate, gauged markers with required maximum and minimum liquid level elevation markings? ❑ Yes ® No Waste Application 10. Are there any buffers that need maintenance/improvement? ❑ Yes ®No 11. Is there evidence of over application? ❑ Excessive Ponding ❑ PAN ❑ Yes ® No 12. Crop type Coastal Bermuda (Hay) Small Grain Overseed Millet Grazed Ryegrass Grazed 13. Do the receiving crops differ with those designated in the Certified Animal Waste Management Plan (CAWMP)? ❑ Yes ® No 14. a) Does the facility lack adequate acreage for land application? ❑ Yes ❑ No b) Does the facility need a wettable acre determination? ® Yes ❑ No c) This facility is pended for a wettable acre determination? ❑ Yes []No 15. Does the receiving crop need improvement? 16. Is there a lack of adequate waste application equipment? Required Records & Documents 17. Fail to have Certificate of Coverage & General Permit readily available? 18. Does the facility fail to have all components of the Certified Animal Waste Management Plan readily available? (ie/ WUP, checklists, design, maps, etc.) 19. Does record keeping need improvement? (ie/ irrigation, freeboard, waste analysis & soil sample reports) 20. Is facility not in compliance with any applicable setback criteria in effect at the time of design? 21. Did the facility fail to have a actively certified operator in charge? 22. Fail to notify regional DWQ of emergency situations as required by General Permit? (ie/ discharge, freeboard problems, over application) 23. Did Reviewer/Inspector fail to discuss review/inspection with on-site representative? 24. Does facility require a follow-up visit by same agency? 25. Were any additional problems noted which cause noncompliance of the Certified AWMP? ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ® Yes ❑ No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ®No ❑ Yes ® No ® Yes ❑ No Nd,Viblhtibiis;or;d6fi iencies�irvere'noted'duriiig-tliis *isit::You`Will;receive no fiirthek�;,, eorredeneeaboutthis.visit.... s on:;.:;..:: s -.t: `: ESE s." - i .; "' 7"k £ . E �t: �En ,r -r -.i€ E. .•<.s `, , [ k -.:.-•••: •. € k .€.€ [ve3.3: ,7.7..:k:EEVi,,I.._Ft . E. VStii IEl.Er..E1�"'IN111:1 �iltE {.F^x fFliE €.:E]E4E1`E7B � 9 j . jSFk ..,•.Ep�t rx..- Comments°(refer, to _[�uest�onE#}:`;Ex lain an{i/.YES[(an wens andlor�an ;recorm endatlonsi1or,Eany,otherl¢icornments�,: - ori any, f �.'l E �7t3 i�e.�:5.r '� P'Ek t.. - r. i.: 1 8 �' �€F4 ..... i .. .e..p • :n1:iF-��{.!{I{[�I£r ,;�N�':�� •E.,. �!il Use drawings! of facility aof better°'lexplaan;s�tuat�ons (aseEadditional �,pages;as6�6neLcessary) . ... ! jjI GI I!I, �I Y ,t .. 1F:i.r ���,. IE{a�.l.{��:��E Etc{ S lE. i�fl:�.[3G kr _ail �.a �ri��. Illl>� r [ .{.-.r<� 6 a nkd�st } s.�iW i. 1 E��E@..>PrR E�,�diL7[� Note: Soil samples have been taken but results were not back at time of review. +� 7- Need to mow inside and outside slopes of lagoon walls for observation and inspections of lagoon walls for rodent damage and possible seepage problems.' 14b- WA Determination required because CAWMP credits field acreage in excess of 75% of the respective field's total acreage. 18- Need to fill out odor control and insect control checklists. Farm is Permitted. Need storage calculations of lagoons with paperwork on farm site from technical specialist which certified the facility. 25- Need to move cows from bermuda spray field. Waste Plan wrote for bermuda hay. 26- Need to extend discharge pipe so waste is discharging at or below lagoon level surface for odor control measures. '!"T 3F Y :_ k E E i3F��f E rr EI C d1 E £� �i E Reviewer/Inspector Name 'Scott F it' s L _E. �t, „1 ,i. d�trr� E Reviewer/Inspector Signature., Date: 3123199 iFacikty Number: 82-114 Date of Inspection 6-23-99 Odor its 26. Does the discharge pipe from the confinement building to the storage pond or lagoon fail to discharge at/or below ® Yes ❑ No liquid level of lagoon or storage pond with no agitation? 27. Are there any dead animals not disposed of properly within 24 hours? ❑ Yes ® No 28. Is there any evidence of wind drift during land application? (i.e. residue on neighboring vegetation, asphalt, ❑ Yes ® No roads, building structure, and/or public property) 29. Is the land application spray system intake not located near the liquid surface of the lagoon? ❑ Yes ® No 30. Were any major maintenance problems with the ventilation fan(s) noted? (i.e. broken fan belts, missing or or broken fan blade(s), inoperable shutters, etc.) ❑ Yes ® No 31. Do the animals feed storage bins fail to have appropriate cover? ❑ Yes ®No 32. Do the flush tanks lack a submerged fill pipe or a permanent/temporary cover? ® Yes ❑ No Additional Comments and/orDrawings: 32- Need to extend fill pipes on flush tanks to bottom of tanks for odor control measures. f Note: Wet area (Oxide Color) was noted on toe of outside slope of lagoon next to woods line behind pump house. Notice of Referral will be sent to Division of Water Quality for testing on wet area (oxide color) for possible seepage problem. w 3123199