May 15, 2019
Subject: Permit No. WQ0040447
Charlotte Water
Rosapenny Road LPSS
Wastewater Collection System Extension Permit
Mecklenburg County
Dear Ms. Cantrell:
In accordance with your application received November 19, 2018, and additional information received on
May 8, 2019, and May 14, 2019, we are forwarding herewith Permit No. WQ0040447, dated May 15, 2019,
to Charlotte Water (Permittee) for the construction and operation upon certification of the subject
wastewater collection system extension. This permit shall be effective from the date of issuance until
rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter and
supplement shall be considered a part of this permit and are therefore incorporated therein by reference.
Please pay particular attention to the following conditions contained within this permit:
Condition 1.1: All low pressure sewers, pressure service laterals, and grinder pump stations shall be
installed outside of the 50-foot buffer of Lake Wylie (Class WS-IV), per 15A NCAC 2T
.0305(f) and the provided plans.
Condition 1.2: Minimum separation for all low pressure sewers shall not be less than 25 feet from
private well, per 15A NCAC 2T.0305(g), and the previously approved variance. All
appurtenances shall remain outside of the 100-foot radius of well in accordance with
15A NCAC 02T.0305(g).
Condition IIA: This permit shall not be automatically transferable; a request must be made and
approved.
Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained
in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system
permit issued to the Permittee.
Condition 11.7: Upon completion of construction and prior to operation of these permitted facilities, the
completed Engineering Certification form attached to this permit shall be submitted with
the required supporting documents to the address provided on the form. Permit
Q�� North Carolina Department of Environmental Quality I Division of Water Resources
lf�e--DE512 North Salisbury Street 1 1617 Mail Service Center I Raleigh, North Carolina 27699-1617
NORiR CAR0I INA -
o.w�a wOmft /'� 919.707.9000
Charlotte Water
Permit No. WQ0040447
modifications are required for any changes resulting in non-compliance with this
permit, regulations, or the Minimum Design Criteria. [15A NCAC 02T.0116]
It shall be responsibility of the Permittee to ensure that the as -constructed project meets the appropriate
design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina
General Statute §143-215.6A through §143-215.6C, construction of additional or replacement
wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to
the licensing board.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to
request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This
request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General
Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC
27699-6714. Unless such demands are made, this permit shall be final and binding.
If you need additional information concerning this matter, please contact Monti Hassan at (919) 707-3626
or via e-mail at Monti.Hassan@ncdenr.gov.
Sincerely,
for Linda Culpepper
Director, Division of Water Resources
by Deborah Gore, Supervisor
Pretreatment, Emergency Response, Collection System Unit
cc: Vincent G. Keene, P.E.; Yarbrough -Williams & Houle, Inc. (vincek@y-wh.com)
Mooresville Regional Office, Water Quality Section Regional Operations
Water Resources Central Files: WQ0040447
PERCS (electronic copy)
Page 2 of 8
NORTH CAROLINA
Environmental Quality
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to
Charlotte Water
for the construction and operation of approximately 1,775 linear feet of 2-inch pressure sewer as well as
14 simplex grinder pump stations with on -site audible and visual high water alarms and associated
pressure service laterals to serve 14 single-family residential homes as part of the Rosapenny Road LPSS
project, and the discharge of 2,660 gallons per day of collected domestic wastewater into the Charlotte
Water's existing sewerage system, pursuant to the application received November 19, 2018, and
additional information received on May 8, 2019, and May 14, 2019, and in conformity with the project
plans, specifications, and other supporting data subsequently filed and approved by the Department of
Environmental Quality and considered a part of this permit.
This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified
conditions and limitations contained therein.
for Linda Culpepper
Director, Division of Water Resources
By Authority of The Environmental Management Commission
Permit Number: WQ0040447
Permit Issued: May 15, 2019
Treatment Facility: McAlpine Creek WWTP (NC0024970)
Page 3 of 8
SUPPLEMENT TO PERMIT COVER SHEET
,The Permittee is hereby authorized to:
Construct, and then operate upon certification the.aforementioned wastewater collection extension.
Permitting of this project.does not constitute an acceptance of ahy part of the.project that does not meet
.15A NCAC 2T;..the .Division's Gravity Sewer Minimum Design Criteria adopted: February .l2, 1996'as
applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and
Force.Mains adopted June 1, 2000 as applicable, unless specifical)y mentioned herein. Division approval
is based on acceptance of the certification.provided'by a North Carolina -licensed Professional Engineer in
the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets
the appropriate design criteria and rules.
Construction and operation is contingent upon compliance with the Standard Conditions and any Special .
Conditions identified below..
I:.: SPECIAL CONDITIONS
1. - All low pressure. sewers, pressure service laterals, and grinder pump stations.shall be installedoutside:.
of the 507-foot buffer of. Lake Wylie (Class WS-IV); per 15A NCAC 2T.0305(f) and the provided plans.
2.- Minimum separation for all low pressure sewers shall not be less than 25 feet from private well, per,
15A NCAC 2T.0305(g) and the previously approved variance. All appurtenances shall remain outside
of the 100400t radius of well in accordance with 15A NCAC 02T.0305(g). .
3. No flow in excess of the quantity permitted herein, 2,660 GPD, shall be made tributary to the subject
sealer system until. an application for permit modification for an increase:in flow has been. submitted
to and approved by the Division. [15A NCAC 02T.0304(b)]
4.: Each pump station shall be clearly and conspicuously posted using a weatherproof sign with a pump
station identifying name number, 24-Hour Emergency telephone number, and name of the
owner/operator of the sewer system/pump station and instructions to call the number in the event
'of alarm activation or other emergency. Simplex pump stations or vacuum sewer pits serving a single-
family residence may have a placard or sticker on the control panel in lieu of assign: [15A NCAC 02T.
:0305(h)(2)]
5. The Permittee shall be responsible for all individual pumps, tanks, service laterals and main -lines :as
permitted. This does not prohibit the Permittee.from entering into a service agreement with another
entity for maintenance or operation. of these units,, however, the Permittee shall be responsible for
correcting any environmental or public health problem with,the system. [15A NCAC 02T.0304(c)]
B. The Permittee shall maintain on hand for immediate installation an adequate supply of spare,:fully
operational pump units of each type used in -the system. [15A NCAC 02T .0305(h)]
Page 4 of 8
II. STANDARD CONDITIONS
1: This permit, shall not be transferable. In the event :there, is a desire for the. wastewater collection
facilities to change ownership, or there is a name change of the Permixtee; a formal permit request
shall be submitted to the Division accompanied by.documentatio.n from the parties involved, and
other, supporting materials as may be appropriate. The approval of this request shall be considered
on its merits and may may not be approved. [15A NCAC 02T.0104; G.S. 143 215.1(d3)]
2.. This permit shall become. voidable unless the wastewater collection facilities are constructed, in
accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum
Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for .
the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and
other supporting materials unless specifically mentioned herein:.[15A NCAC, 02T.0110]
3. This permit shall be effective only with -respect to the nature and volume of wastes described in the.
application and other supporting data. [15A NCAC 02T .0110]
4. The wastewater collection facilities shall be properly maintained and operated at all times. The
Permittee shall maintain, compliance with an individual system -wide collection system permit for the
operation and maintenance of these facilities -as required by 15A NCAC 02T.0403. If an individual
permit is not required; the following performance criteria shall be met:
a. The sewer. system shall'be effectively maintained. and operated at all times to prevent discharge
to land or surface waters, and to. prevent any contravention of groundwater standards or surface
water standards.
b. A map of the -sewer system shall be developed and shall be actively maintained:
c. An operation -and maintenance plan including pump station inspection frequency, preventative
maintenance schedule, spare parts inventory and overflow response has been developed and
implemented;.
d. Pump stations thatare not connected. to a telemetry system shall be inspected every day (i.e. 365
days,per year): Pump stations that are connected to a telemetry system shall be inspected at
least once per week:
e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are
documented.
f. A general observation. of the entire sewer system shall be conducted at least.once per year.,
g. Overflows and bypasses shall be reported to the appropriate.Division regional office in accordance -
with. 15A NCAC 213- 0506(a), and public.notice shall be provided asrequired by North Carolina
General Statute §143-215.1C..
h: A Grease Control Program is in. Place as follows:
1. For public owned. collection systems, the Grease Control Program shall include at least
biannual distribution of educational materials for both commercial and residential users and
Page 5 of 8
the legal means to require grease interceptors at existing establishments..The plan shall also
.include legalmeans for inspections of the grease interceptors,_ enforcement for violators and
the legal means to "control grease entering the system.from other public.and private satellite
sewers ystems.
2. . For privately owned collection systems, the Grease Control Program shall include at least bi-
annual distribution of grease education materials.to users of the collection system by the
:permittee or its representative.,
3. -. Grease education materials shall be distributed more often than required in,.Parts (1) and (2).
of this Subparagraph if necessary to prevent grease -related, sanitary sewer overflows. .
i. Right-of-ways and easements shall. be maintained in the full easement width for personnel and
equipment accessibility.
j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum ofthree
years with exception of the map, which shall be maintained for the life of the system:
5. Noncompliance Notification:
The Permittee shall report_ by telephone to a water resources staff member at the Mooresville
Regional Office, telephone number (704) 663-1699, as soon.as possible, but in no case, more than 24
hours, following the occurrence or_first knowledge of the occurrence:of.either of the:following:
a. 'Any process unit failure; duo to known or unknowhyeasons, that. renders the facility.incapable
of adequate wastewater transport, such as mechanical or electrical failures of pumps; line
blockage or breakage, etc.; or ,
b.: Any SSO and/or spill over 1,000 gallons; or
c. Any SSO and/or spill,.regardless:ofvolume, that reaches surface water
Voice mail. messages or faxed information is permissible, but this shall not -be considered as the initial
verbal report. Overflows and spills occurring outside normal business hours may also be reported to
the Division of Emergency Management_ at telephone number. (800) 858-0368 or. (919) 733-3300.
Persons reporting any of the above occurrences shall file a;spill report by completing and submitting
Part I of Form CS-SSO (or the most current Division approved,form) within five days following first.
knowledge of the occurrence: This report must outline the actions taken.or proposed to be taken;to
ensure that the problem does not recur. Part II of Form CS7S50 (or the most current Division approved
form) can also, be completed to show that the SSO was beyond control. [G:S. 143-215.1C(a1)]
6. Construction of the gravity sewers;.pump stations, and force mains shall be scheduled so as not to
interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater
to the surface. waters of the State. [15A NCAC 02T.0108(b)]
7.. Upon completion 'of.construction and. prior to operation of these permitted facilities, the completed.
Engineering Certification form attached to this permit shall be submitted with the required -supporting
documents to the address provided on the form. A complete certification is one where the form is
fully.executed;and the supporting documents are provided as applicable. Any wastewater flow.made
tributary to the wastewater collection system extension prior to completionof this Engineer's
Certification shall be considered, a violation of the permit and shallsubject the Permittee to
appropriate enforcement actions...
Page 6 of 8 . .
If the permit is issued to_a private entity with an Operational Agreement, then a copy of the Articles
of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately
filed with the applicable County's Register of Deeds office shall be submitted with the certification.
A complete certification is one where the form is fully executed and'the supporting documents are
provided as applicable. Supporting documentation shall include the.following:
a. One copy of the project construction record drawings (plan & profile views of sewer lines & force
mains) of the wastewater collection system extension. Final record drawings should be clear on
the plans -or on digital media (CD or DVD disk) and ,are defined as the design drawings that are
marked up or annotated with after construction information and show required buffers,
separation distances, material changes, etc.
b. Changes to the project that do not result in non-compliance with this permit, regulations, or the
Minimum Design Criteria -should be: clearly identified:on the record drawings, on the Certification:
in the space provided, or in written summary 'form.,
Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting
in non-compliance with this permit (including but not limited to pipelength changes -of 10% or
greater,. increased' flow, pump station design .capacity design increases of 5% or greater, and
increases in the number/type 'of .connections), regulations,' or .the Minimum Design Criteria.
Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case. -by --
case basis and each on its. own merit: Please note that variances -to the Minimum Design Criteria
should be requested and.•approved during the permitting process prior to construction. After --
construction requests are discouraged by the Division and may.not be: approved; jhus requiring
replacement or repair prior: to certification, &.activation. [15A NCAC 02T .0116]
8. Gravitysewers installed greaterthan ten percent.below:the minimum required'slope perthe Division's
Gravity Sewer. Minimum Design Criteria shall not be acceptable and shall not be certified until
corrected. If there isan unforeseen obstacle in the field where all viable solutions have been
examined, a slope variance can be requested from the'Division with firm supporting documentation.
This shall be done through a permit modification with fee. Such _variance requests will be evaluated
on a case-by=casebasis: Resolution of such request shall be evident priorto completing and submitting
the construction certification. [ 15A NCAC 02T.0105(n)]
9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life,of
the wastewater -collection facilities. [15A NCAC 02T..0116]
10. Failure to abide by the conditions and limitations contained in thN-permit;15A NCAC 2T; the Division's
Gravity Sewer Design Criteria adopted February 12,1996 as applicable; the Division's Minimum Design
Criteria for the Fast -Track Permitting'of Pump Station and Force Mains adopted June 1, 2000 as
applicable; and other supporting materials may subject the Permittee to an enforcement action by
the Division, in accordance with North. Carolina General Statutes §1437215.6A through §143-215.6C; .
construction of additional or replacement wastewater collection facilities; and/or referral of the North
Carolina -licensed Professional Engineer to the licensing board.. [15A NCAC 02T .0108(b-c)]-
11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the
creation of nuisance conditions,.the Permittee shall take immediate corrective action, including those
Page 7 of 8
as maybe required by this Division, such as the construction of additional or. replacement facilities.
[15A NCAC 02T .0110; 15A NCAC 02T .0108(b)]
12. The issuance of this permit shall not exempt -the Permittee from complying with any and all statutes,
rules, regulations, or ordinances that may be imposed by the Division any other.Federal, State, or Local
government agencies which have. juri.sd'iction or obtaining other permits which maybe required.by the
Division or any other Federal, State, of:Local government agencies. [G.S.143-215.1(b)]
13. The Permittee shall provide for the pump station and force main the following items:
a. Pump Station Reliability [15A-NCAC 02T .0305(h)(1)]:
'1. Pump stations, except when exempted by. Subparagraph fl)(2) of. 15A NCAC 02T.0305,
shall be designed with multiple pumps such that peak -flow can be pumped with the
largest pump out of service.
2. A staridby. power source or pump is required -at all .p.uinp stations exceptior those pump
stations subject to Subparagraph 0)(2) of 15A NCAC 02T.0305. Controls shall be provided
to automatically activate the standby source and signal an alarm condition.
3. . As an, alternative to Part (c) for pump stations.with an average daily. design flow less than
15,000 gallons per dayas'calculated using 15A NCAC-02T:0114, aportable power source
or, pumping. capability. may be utilized. It shall be demonstrated to -the Division that the -
portable source :is ownedor contracted, by.th(§ Permittee-,and is.compatible'with the
station. If the. portable power source or pump is dedicated tomultiple pump stations, an.
evaluation of -'all. the pump.stations' storage capacities and the rotation, schedule of the
portable power source or pump, including:travel timeframes, shall be provided, in the case
of a'multiple station power:outage. .
4. As an alternative to Part (ii) for pump or Vacuum stations_ connecting a single.building to.
an alternative sewer system, wet well storage requirements shall :bg documented to
provide 24-hours' worth. of wastewater storage or, exceed the greatest power outage
over the last three years or the documented response time to replace a failed pump,
whichever. is greater,. Documentation shall be -required pursuant to the permit
application.
b.. All -pump stations .designed for two pumps or more shall have, a telemetry system to. provide
remote notification ofa problem condition to include power failure and high water alarm. [15A
NCAC 02T .0305(h)(1)(E)]
c. High water audio and visual alarm. [15A NCAC 02T .0305(h).(1)(F)]
d. Pump stations shall have a permanent weatherproof, sign stating the pump station identifier, 24-
hour emergency number. and instructions to call in case of emergency. Simplex pump or vacuum
stations serving a single, -family residence shall, have a placard.or sticker placed inside the control
panel with a 24-hour emergency contact number: [15A NCAC 02T .0305(h)(2)] .
e. Screened vents for all wet wells. [15A NCAC 02T .0305,(h)(3)]
f. The public shall be restricted access to the site and equipment. [15A NCAC 02T .0305(h)(4)]
g. Air'relief valves shall be provided at all high points along force mains where the vertical distance
exceeds ten .feet. [15A NCAC 02T .0305(h)(5)]
Page 8 of 8 .
ENGINEERING CERTIFICATION
Permittee: Charlotte Water
Permit No: WQ0040447
Project: Rosapenny Road LPSS
Issue Date: May 15, 2019
county: Mecklenburg
This project shall not be. considered complete nor allowed to operate in accordance with Condition 7 of this permit
until the Division has received this Certification and all required supporting documentation, which includes:
• One copy of the.project construction' record drawings (plan & profile views of sewer lines & force mains) of
the wastewater collection system extension.. Final record drawings should be clear on the plans or on digital
media (CD or DO disk) and are defined as the design drawings that are marked up or annotated with after.
construction information and show required buffers, separation distances, material changes, etc.
Permit modifications are required for any: changes resulting in non, compliance with this permit. A detailed
description for partial certifications should be attached to this form along with any certification,comments.
Certification. should be submitted in a manner. that documents the Division's receipt. The Permittee is responsible
for tracking all. partial certifications up until a final certification is received.
PERIVI&EE'S CERTIFICATION
I; the -undersigned agent for the. Permittee, hereby state that this project has been constructed. pursuant to the
applicable standards & requirements, the Professional Engineer below has provided applicable design/construction
information to.the,Permittee, and the Permittee is prepared to operate & maintain -the wastewater collection system
permitted herein or pottions thereof.
Printed Name, Title Signature Date
ENGINEERS CERTIFICATION
as a duly. registered Professional Engineer in the State of North Carolina, having
been authorized to observe (❑ periodically,. ❑ weekly; ❑ full time) the construction of the project name and
location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and
diligence .was used ,in the 'observation of the following construction: approximately 1,775 linear feet of 2-inch
pressure sewer as well as 14 simplex grinder pump stations with on -site audible and visual high water alarms and
associated pressure service laterals to serve 14'sinIgle-family residential homes as part of the Rosapenny Road LPSS
project,' and in conformity with the project plans, specifications, supporting documents,' and 'design criteria
subsequently filed and approved. I certify that the construction of the above referenced project was observed to be
built within substantial compliance and intent of the approved plans and specifications.
North Carolina Professional Engineer's Seal w/signature & date:
❑ Final ❑ Partial (include description)
Send the Completed Form & Supporting Documentation to the Following Address:
DWR WATER QUALITY PERMITTING SECTION
WASTEWATER BRANCH — PERCS UNIT
1617 Mail Service Center
Raleigh, NC 21699