PLAN OF ACTION(Poa) FOR HIGH FREEBOARD AT ANIMAL FACILITIES
91-'113
to - ct
Facility Number. 31/713 IV ;3
County: Duplin
Facility Name: Next Generation Family Ventures
Certified Operator Name: Nick Edwards
Operator Number. 996567
1. Current liquid level(s) in inches as measured from the current liquid level in the lagoon to the
lowest point on the top of the dam for lagoons without spillways; and from the current liquid level
in the lagoon to the bottom of the spillway for lagoons with spillways,
Lagoon 1 Lagoon 2 Lagoon 3 Lagoon 4 Lagoon 5
Lagoon Name/ID: 1
Spiliway(Y or N): N
Level(mches): 1 g
2. Check all applicable items
Liquid level is within the designed structural freeboard elevations of one or more structures.
Five and 30 day Plans of Action are attached. Hydraulic and agronomic balances are
within acceptable ranges
X Liquid level is within the 25 year 24 hour storm elevation for Mr Dotsons structure. A
30 day Plan of Action is attached. Agronomic balance is within acceptable range.
Waste is to be pumped and hauled to off site locations. Boiume and PAN content of waste
to be pumped and hauled is reflected in section III tables. Included within this plan is a list
of the proposed sites with related facility numbers, number of acres and receiving crop
information. Contact and secure approval from the DWQ prior to transfer of waste to a site
not covered in the facility's CAWMP.
Operation will be partiallyor fully depopulated.
'Attach a complete schedule with corresponding animal units and dates fro depopulation
'if animals are to be moved to another permitted facility, provide facility number, lagoon
freeboard levels and herd population for the receiving facilfty
3. Earliest possible date to begin land application of waste: 6/8/2018
1 hereby certify that I have reviewed the information listed above and included within the
attached Plan of Action, and to the best of my knowledge and ability, the information is
accurate and correct
Nick Edwards Phone: 910 298 3012
Faciliiy Owner/Manager rint
�J
Date. 611/2018
acility Own anager (signature)
IL TOTAL POUNDS OF PAN STORED WITHIN STRUCTURAL FREEBOARD AND/OR 25 YRJ24
HR. STORM STORAGE ELEVATIONS IN ALL WASTE STRUCTURES FOR FACILITY
Structure ID: NG3
line m = 907.E lb PAN
n.lines 1+2+3+4+5+6=
907.8 lb PAN
III. TOTAL PAN BALANCE REMAINING FOR AVAILABLE CROPS DURING 30 DAY DRAW DOWN
PERIOD. DO NOT LIST FIELDS TO WHICH PAN CANNOT BE APPLIED DURING THIS 30 DAY PE
D. tract # p. field # q, crop r. acres S. rertreW IRR LL TOTAL PAN
8 u. eppflcahon
2 PAN balance BALANCE FOR
(Ib/acre) FIELD pbs,)
VG3 PPI po ,, coltum r x s
State current crop ending application date or next crop application beginning date for available
receiving Crops during 30 day draw down period.
v. Total PAN available for all fields (sum of column t =
IV. FACILITY'S PoA OVERALL PAN BALANCE ) 6412.4 lb. PAN
W. Total PAN to be land applied (line n from section 11) = 907.8 lb. PAN
PoA (30 Day) 2/21/00
x. CroP's remaining PAN balance (line v from section 111) =
Y. Overall PAN balance (w -x) _ 8412 5505 lb. PAN
Line y must show as a deficit. If line y does not show as a deficit, list course of action here Including Pump and
haul, depopulation, herd reduction, etc. For pump & haul and herd reduction options, recalculate new PAN
based on new Information. If new fields are to be included as an option for lowering lagoon level, add these
I
to the PAN balance table and recalculate the overall PAN balance. If animal waste is to be hauled to
another permitted facility, Provide Information regarding the herd population and lagoon freeboard levels at the
receiving facility.
PoA (30 Day) 2121/00
PLAN OF ACTION (POA) FOR HIGH FREEBOARD AT ANIMAL FACILITIES
30 DAY DRAW DOWN PERIOD
I. TOTAL PAN TO BE LAND APPLIED PER WASTE STRUCTURE
I. Structure Name/Identifier (ID): NG3
2. Current liquid volume in 25 yrJ24 hr. storm storage & structural freeboard
a. current liquid level according to marker
b. designed 25 yrJ24 hr. storm & structural freeboard
c. line b - line a (inches In red zone) _
d. top of dike surface area according to design
(area at below structural freeboard elevation)
e. line c/12 x line d x 7.48 gallons/ft3
3. Projected volume of waste liquid produced during draw down period
f. temporary storage period according to structural design
18.0 inches
19.0 inches
1.0 inches
88320 ftZ
55053 gallons
180 days
g. volume of waste produced according to structural design 116047 ft3
h current herd # F--2-96-01 certified herd # 3520
actual waste produced = current herd # x line g =
certified herd #
I. volume of wash water according to structural design
j. excess rainfall over evaporation according to design
k. (lines h + i + t) x 7.48 x 30 days/line f=
4. Total PAN to be land applied during draw down period
I. current waste analysis dated 4/13/2018
m. (pines e + k)/1000) x line I =
PoA (30 Day) 2121/00
97585 ft'
--e
�-J ft3
385-00�ft3
169653 gallons
4.04 Ibs/1000 gal.
907.8 lbs. PAN
NCDABCS Agronomic Division
Farm:310713
Predictive
Phone: (919) 733"2665 Webslte: www.ncagr.go0/agronoml/
W- - a-ste Report
LIn¢(iu11,Lu JUfpn77ntl�q Sampled: 04/13/2018
Received:, 04/16/2018
Completed: 04/20/2018
Client: Next Generation Fanuty Ventures,
LLC
314 Willard Edwards Rd
Beulavllle, NC 2851 a
Duplin County
PALS #•407124
Report No. FY18-WO08212
Advisor. Jon Rlsgaard
512 N Salisbury St 6404
Raleigh, NC 27604
Samole Information
Nutrieflt Measurements are
PALS #: 485612
ID: NG3
jNJIo en
given m units of parts per million u
(ppm), unless utherwlse
specrted.
Code: ALS
Total N:
P K Ca Mg S Fe Mn Zn
217
Cu B
I Other Results
Mo
Description: Swine
Total N: 968
889 334 163 t15 51.5 5.06 16.8
21 2 0 89
C Al Ne Cl
Lagoon Llq.
inorganic-
L — — — — -- — — _
I _
5,18 21B
GrowerComments:
NH4-N
— — —
I SS — — — — — _
PH BD
—'
—— — — — — — —
NotProvided
NO3-N .
CCE
(10s S/cm) (mS cm) UnlUess
( ) (Ib/y(')
ALE
— —
C:N
(1000 gal)
(Unitiess) (oM
Estimate of Nutrients Available for First Year
Application Method:
N
(lb/1000 gal)
P205 K20 Ca Mg
Other Results (Ib/1000
Irrigation
4.04
S Fe Mn Zn
4.14 8.90 2.79 1.36 0.98 0.43
Cu B
gel)
Mo I Na4 Cl
0.04 0.14
0.18 0.01
00 .
- � "
1.82
NorthCarolina
n
I „ J _ tom' A�arr° Tiusl I and Camnbsl°n
Reprogramming of the laboratory -information -management system that makes this report possible is being funded
through a grant from the North Carolina Tobacco Trust Fund Commission
7hw)1c yolr for using 4gl ouanrc services to rnauage rwrrients rmd sajegrrard errvirorrmeulal rprality.
S""e Trorler, ConmrlssionerajAgnc rinar,