Loading...
HomeMy WebLinkAbout20190651 Ver 1_Site Plan Drawings 5-14-19_20190514VICINITY MAP HYDROLOGY LEGEND N JURISDICTIONAL TRIBUTARY _ ISOLATED WETLAND (STREAMS) W-5: 0.3 ac Pocosin JURISDICTIONAL WoUS 1 m I i RR x ,ry SITE LOCATION IV:g,S , NON -JURISDICTIONAL DITCH k \ cffff// c i O f - --� ISOLATED WETLAND Basin o , "r SCALE 1" = 1o,Uo0' y -- - EXISTING OVERHEAD ELECTRICAL TRANSMISSION LINES (TYP.) JURISDICTIONAL WETLAND (TYP.) ISOLATED WETLAND W-7: 0.3 ac Pocosin ARRAY AREA (TYP.) w A Lt ARRAY AREA (TYP) ` IMPACT NO. 5 l DITCH 1 WETLAND (SEE SHEET EX106) i t k i IMPACT NO. 1 STREAM / DITCH (SEE SHEET EX102) (SEE SHEET EX107) e IMPACT NO, 2 U ro co J o C, STREAM/WETLAND j o N o z (SEE SHEET EX103) Co z Ili J(/) W m Z O Lu ¢ LU Z 2 O LLJZ F Z 00 V,/^ PafIn U J ) zR W 30' JURISDICTIONAL U) Q STREAM OFFSET (TYP.) Lij p Q w IMPACT NO, 3 ^ rn }L�� Z STREAM /WETLAND 1 DITCH (SEE SHEET EX104) W \ o_ W LU IMPACT LEGEND EXISTING CONDITIONS *F - BUILDING SETBACK — — OVERHEAD ELECTRICAL MAJOR CONTOUR MINOR CONTOUR f PROPERTY BOUNDARY — — — PROPERTY (ADJOINER) RIGHT-OF-WAY STREET CENTERLINE - TREELINE TOP OF BANK JURISDICTIONAL WETLAND J 1 GRAPHIC SCALE I a Soo 1.Dan I� Clam*Mdi# 1" = 1,000' PROPOSED CONDITIONS OVERHEAD ELECTRICAL OHE — EASEMENT/BUFFER OFFSET L GRAVEL ACCESS ROAD TREELINE .(-YY-Y-Y1 LU Q O z z V 0 �D_ON U 0 -10Qz O Q wWm0 0- IXOLUJ= } O w Of QOD(tO Q mNQZ j 2 0 DRAWN WRB CHECK: KPB DATE: 5110/11 EX101 Jurisdictional RPW (Non-Stream) This Side of Road IMPACT O1: 0.01 ac total (includes both permanent and temporary impacts) Intermittent Stream This Side of Road IMPACT S3 (TEMP) IMPACT S2 (TEMP) IMPACT S1 (PERM) 6 LF CULVERT IMPACT S1 IMPACT S2 IMPACT S3 IMPACT O1 (S1) IMPACT S6 (TEMP) IMPACT S5 (TEMP) IMPACT S4 (PERMANENT) IMPACT S5 (TEMP) IMPACT S6 (TEMP) IMPACT W1 (PERM) IMPACT S4 IMPACT S5 IMPACT S6 IMPACT W1 IMPACT O2: 0.01 acre total (Includes both permanent and temporary impacts) IMPACT W2 (PERM) IMPACT S8 (TEMP) IMPACT S7 (TEMP) Intermittent Stream This Side of RoadJurisdictional RPW (Non-Stream) This Side of Road IMPACT S7 IMPACT S8 IMPACT W2 IMPACT O2 (REPLACE) 20 LF IMPACT O3: 0.1 acre total IMPACT O3 IMPACT O4: 0.1 acre total IMPACT W3 (PERM) IMPACT O4 IMPACT W3 IMPACT O5: 0.01 acre total IMPACT O5 IMPACT W4 IMPACT W4 (PERM) 20' �- TEMPORARY Alk IMPERVIOUS DIKE - LOCATION J VARIES (TYP.)(SEE NOTE) OUTLET PROTECTION (SEE LOCATION DETAILS FOR SIZE) LF - VARIES (PERMANENT IMPACT) 5'NIIN 14'OR20' VMIN 10' 20' VARIES A (MIN.) TEMPORARY 1' THICK CLASS "B" RIP RAP SIDE SLOPE ARMORING WITH NON -WOVEN TYPE 2 GEOTEXTILE 1.5:1 MAX - -3 � � '- 1 5'1 MAX i� CLASS IV RCP OR BOX CULVERT \\ �11 (SIZE/LENGTH VARIES) — — — —� _ \ NOTE: IMPERVIOUS DIKE TO BE CONSTRUCTED WITH STONE ENCAPSULA-ED WITH IMPERVIOUS GEOTEXTILE OR ENGINEER AIPROVED EQUAL) ENERGY OtSSIPAI]ON DE'4MATERIN3 DEVICE "OTE: ENSURE TOANCMORALL PUMPS AND PIPES SECURELY. CRUSHED ABC STONE BEDDING 0 0 0 0 Cp O o i FOR ELECTRICAL CONDUITS A DC AND MVCROSSING 3" (MIN.) UNDER PIPE BEDDING (TYP.) 14.5' (MAX.) VARIES \ t PLACEMENT OF BOX CULVERT MUST BE BELOW ELEVATION OF THE STREAMBED 1' (M IN.) PLACEMENT OF RCP MUST BE BELOW ELEVATION OF THE STREAMBED BY 205% OF THE RCP DIAMETER STONE BEDDING D0124 (MIN.) NOT LESS THAN 3" 12" (MIN.) TO CAUTION -APE PLACED OVER CONDUIT (TYP.) STREAM/DITCH CROSSING IMPACT (ACCESS ROAD ( NOT TO SCALE) MANAGING THE WATERCOURSE. - BYPASS PUMPING IMPERWOUS DIKE FLCSyy>~_ DISCHARGE HOSE PiI1611'riCA_YP — TOP OF BMIK IMPERVIOUS DIKE WORK AREA FINISHEDGRADE COMPACTED EARTHFILL (6" LIFTS MAX) y w NON -WOVEN TYPE 2 - GEOTEXTILE TOE OF EXISTING DITCH ISTREAM (D) CLASS N RCP (TYP.) r 12" MIN. COVER EXISTING GRADE (EYP.) (STRIP AND REMOVE TOPSOIL ANDIOR ORGANICS FROM CONSTRUCTION AREA) 'y �/' INVERT OF CULVERT MUST BE INSTALLED + / r LOWER (20% OF THE CULVERT DIA) THE i EXISTING STREAMBED OR DITCH �j ,� PLACE GEOTEXTILE FABRIC AND 3" TO 6" OF ABC IN BOTTOM 1' (MIN.) -- 12" MIN. COVER BEFORE INSTALLING CULVERT I (TYP) VARIES -� 6" DC AND OR MV Tj CONDUIT CROSSING ` 3" (MIN.) CLASS IV RCP CROSS SECTION FINISHED GRADE COMPACTED EARTHFILL ��. (8" LIFTS MAX) w NON -WOVEN TYPE2 a GEOTEXTILE i TOE OF EXISTING STREAM \ I NOT TO SCALE) 12" MIN, COVER OR 8' -4- v TYPE 1 BOX CULVERT (TYP.) EXISTING GRADE (TYP.) (STRIP AND REMOVE TOFSOIL AND/OR ORGANICS FROM CONSTRUCTION AREA) INVERT OF CULVERT MUST BE INSTALLED 1' BELOW(MIN.) THE PLACE GEOTEXTILE FABRIC 3" (MIN.) EXISTING STREAMBED OR DITCH c AND 1" (MIN.) OF ABC IN BOTTOM BEFORE INSTALLING CULVERT TT .. .. ` 12" MIN. COVER 6" DC AND OR MV VARIES CONDUIT CROSSING BOX CULVERT CROSS SECTION A—A (NOT TO SCALE) J/1/ O '�/ O ° _ Q O n Qz V � Y N N z a+ � o w o0a¢� WJ 2UVIN < fUlzoZ LLl 3 x¢20- Nx a 500 F� '^ o FZz lJJ 3o~oN0m W LL zo Oo7)� ( ^1 lu i V ut 'n 03 0 om U m (� M co J O r O Z M N 0 U Q C) p Z W 0 Y m W zz LLu U QUA �o z = U 00 O Z U F_ �w (nww ao� aw W v o af O = N 0 } N R z U o° Z O F- d U U) LU 0 LU F - Q O Z cV LL 0 C0 �O_ON J (7 W 0 O p cn w O Q LuW 0 Lu cl�Ovi H w J = Q � (7 w F--mNw0 C) tiaz Q 2 n 73 DATE: 1 5/10119 EX109