Loading...
HomeMy WebLinkAbout310668_Plan of Action_20180813I ,N (V c�z (t b t 10 5- PLAN OF ACTION(Poa) FOR HIGH FREEBOARD AT ANIMAL FACILITIES Facility Number 31-668 County Duplin Facility Name E&S Nursery Certified Operator Name: Ira Delana Johnson Operator Number. #20098 1 Current liquid level(s) in inches as measured from the current liquid level in the lagoon to the Lowest point on the top of the dam for lagoons without spillways; and from the current liquid level in the lagoon to the bottom of the spillway for lagoons with spillways. Lagoon Name/ID Spillway(Y or N) Level(inches) Lagoon 1 Lagoon 2 Lagoon 3 Lagoon 4 Lagoon 5 17 2. Check all applicable items Liquid level is within the designed structural freeboard elevations of one or more structures. Five and 30 day Plans of Action are attached Hydraulic and agronomic balances are within acceptable ranges X Liquid level is within the 25 year 24 hour storm elevations for one or more structures. A 30 day Plan of Action is attached. Agronomic balance is within acceptable range Waste is to be pumped and hauled to off site locations. Volume and PAN content of waste to be pumped and hauled is reflected in section III tables. Included within this plan is a list of the proposed sites with related facility numbers, number of acres and receiving crop information Contact and secure approval from the DWQ prior to transfer of waste to a site not covered in the facility's CAWMP. Operation will be partially or fully depopulated. `Attach a complete schedule with corresponding animal units and dates fro depopulation Y animals are to be moved to another permitted facility, provide facility number, lagoon freeboard levels and herd population for the receiving facility 3 Earliest possible date to begin land application of waste, 8/16/2018 I hereby certify that I have reviewed the information listed above and included within the attached Plan of Action, and to the best of my knowledge and ability, the information is accurate and correct. Ira Delana Johnson Phone 910-284-0426 Facility Owner/Manager (print) Ira Delana Johnson Date 8/13/2018 Facility Owner/Manager (signature) n II.. TOTAL POUNDS OF PAN STORED WITHIN STRUCTURAL FREEBOARD AND/OR 25 YR./24 HR. STORM STORAGE ELEVATIONS IN ALL WASTE STRUCTURES FOR FACILITY 1 Structure ID: E&S Nursery line m = 425 4 lb PAN 2. Structure ID line m = lb PAN 3. Structure ID line m = lb PAN 4 Structure ID line m = lb PAN 5 Structure ID. line m = lb PAN 6 Structure ID line m = lb PAN n.lines 1+2+3+4+5+6= 4254lbPAN III. TOTAL PAN BALANCE REMAINING FOR AVAILABLE CROPS DURING 30 DAY DRAW DOWN PERIOD. DO NOT LIST FIELDS TO WHICH PAN CANNOT BE APPLIED DURING THIS 30 DAY PERIOD. o tract # p field # q. crop r acres s remaining IRR 2 PAN balance (Ib/acre) t TOTAL PAN BALANCE FOR FIELD (lbs.) column r x s u apphnhon window' F1 Wheat 21.28 14400 3064.3 4/01-9/15 'State current crop ending application date or next crop application beginning date for available receiving crops dunng 30 day draw down period. v. Total PAN available for all fields (sum of column t) = 3064 3 lb. PAN IV. FACILITY'S PDA OVERALL PAN BALANCE w. Total PAN to be land applied (line n from section II) = 425 4 lb. PAN FDA (30 Day) 2/21/00 x. Crop's remaining PAN balance (line v from section III) = 3064.3 lb. PAN y. Overall PAN balance (w - x) _ -2639 lb. PAN Line y must show as a deficit If line y does not show as a deficit, list course of action here including pump and haul, depopulation, herd reduction, etc For pump & haul and herd reduction options, recalculate new PAN based on new information If new fields are to be included as an option for lowering lagoon level, add these fields to the PAN balance table and recalculate the overall PAN balance If animal waste is to be hauled to another permitted facility, provide information regarding the herd population and lagoon freeboard levels at the receiving facility August waste sample to be submitted to NCDA, for start of wheat season. Corn to be harvested week of August 13th, 2018 DWR will be notified just as soon as farm is in compliance with lagoon level. PoA (30 Day) 2121/00' PLAN OF ACTION (PoA) FOR HIGH FREEBOARD AT ANIMAL FACILITIES 30 DAY DRAW DOWN PERIOD I. TOTAL PAN TO BE LAND APPLIED PER WASTE STRUCTURE 1. Structure Name/Identifier (ID)' I E&S Nursery 2. Current liquid volume in 25 yr/24 hr storm storage & structural freeboard a. current liquid level according to marker b designed 25 yr/24 hr. storm & structural freeboard c. line b - line a (inches in red zone) = d. top of dike surface area according to design (area at below structural freeboard elevation) e. line c/12 x line d x 7.48 gallons/ft3 3. Projected volume of waste liquid produced during draw down period f. temporary storage period according to structural design 17.0 inches 19.0 inches 20 inches 39,000 ft2 48620 gallons 180 days g. volume of waste produced according to structural design 41026 ft3 h current herd # 5600 certified herd # 5600 actual waste produced = current herd # x line g = certified herd # i. volume of wash water according to structural design j excess rainfall over evaporation according to design k (lines h + i +j) x 7.48 x 30 daystline f= 4 Total PAN to be land applied during draw down period I current waste analysis dated 5l17/2018 m ((lines e + k)/1000) x line I = REPEAT SECTION I FOR EACH WASTE STRUCTURE ON SITE. (Click on the next Structure tab shown below) 41026 ft3 Oft3 22750 ft3 79507 gallons 3.32 Ibs/1000 gal 426.4 tbs. PAN PoA (30 Day) 2/21/00