Loading...
HomeMy WebLinkAboutWQ0040847_Application (FTSE)_20190402• State of North Carolina 6WR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number; `�� t (ti�hcc;Fiupleredhy f]IVR) All items must be completed or the annlication will be returned I. APPLICANT INFORMATION: I. Applicant's name: Fitch Creations Inc. (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State -County ❑ Municipal ❑ Other 3. Signature authority's name: Roy R_ Fitch. Jr. per 15A NCAC 02'1 _0106(b) w� Title: President 4. Applicant's mailing address: 2000 F`earringtor�i;e Center 1 Cite{ Pittsboro State: NC Zip: 27312- ��i/ ) 5. Applicant's contact information: v l% Phone number: (919) 542-2000 lvrmail Address: rb c3fearrinzton_com 11. PROJECT INFORMATION: ty %, SQL f } 1. Project name. Fearrinaton Section X Area D Phasel�' 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permi0roject If`a modification, provide the existing permit number: WQOD and issued date: li ne�� construction but part ofa master plan, provide the existing permit number: WQ00 3 Count) w.lere project is located: Chatham 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.7922 Longitude:-79.0866 5. Parcel I D (if applicable): (or Parcel ID to closest downstream sewer) C': Ill. CONSULTANT INFORMATION: qu N o tr 1. Professional Engineer: Alan R. Keith License Number: 133711 c �, •gip Firm: Diehl &-, Phillips, P.A. c t Mailing address: 1500 Piney plains Road Suite 200 c C .on Cite: Ctiry State: NC dip: 275 i 8- A Phone number: (919) 467-9972 Email Address: arkeith(opbellsouth.net IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Faciliq Name: Fearrin gton WWTP Permit Nurnber: NCO043559 O\sner Name. Fitch Creations, Inc. V. RECEIVING DOWNSTREAM SEWER INFORMATION (i1'different than WWTF): I. Permit Number(s): \\IQ0040057 Downstream (Receiving) Sewer Size_ 8 inch System l\ ide Collection System Permit Number(s) (il'applicable): WQCS.00238 Owner Name(s): Pitch Creations, Inc. FORM: l--l-A 04-16 Page I of-5 V1. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ® Yes ❑No ❑N: A 2. If the Applicant is it Developer of lots to be sold, has it Developer's Operational Agreement (FORM: DEV) been attached' ❑ Yes ❑No ON . -A 3. If the Applicant is a Home/Prop2rty Owners'_ Assoc iation- has _an Operational Agreement (FORM: 140A) been attached? ❑ Yes [—]No ON . -A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retaii (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparationservice ❑ Hotel and?or Motels ❑ School / preschool / day care ❑ Medical! dental ' veterinary i'acilities ❑ Swimming Poo! !Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool?Filter Backwash ❑ Businesses I offices I factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nalurc ot•wastewater : 100 % Domestic/Commercial % Commercial % Industrial (See_15A NCAC _02T,0.103(20]) �Is there a Pretreatment Program in effect? ❑ Yes ❑ No G. 1-1as a flow reduction been approved under I5A NCAC 02T .01 M ? ®Yes ❑ No If ves, provide a con, of flow reduction approval letter 7. Summarize wastewater ,generated by project: Establishmeni Type (see 02T.01 14(1)) Daily Design Flow ° t' No. of Units Flow Single family residential lots 250 gal/day 21 5,250 GPD tya11 GPD gale GPD gale GPD gal.+ GPD gal/ GPD Toml 5,250 GPD a See 1 iA NCAC 02T .01 14(b). d e I an([ e ? for caveats to uaslewater design flow rates (i.e., minimum flow per d�►elling; proposed unknown non-residential development uses; public access facilities located near high public use areas, - and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .01 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 14] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 5�2 0 GPD (per I5A NCAC 02T .01 14) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existin,U sewer with no nen flo%k- expected ❑ Other (Explain): 1701ZM. 17TA 04-16 Page 2 of 5 VII. GRAVITV SEWER DESIGN CRITERIA (II'Applienble) - 02T.0305 S MDC (Gravity Sewers): 1. Summarize graviq- sewer to be permitted; Size (inches) T Length (feet) Material 8 554 PVC 8 119 DI 3 Section ll & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria Section III contains information related to mininiu n slopes For gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vill. PUMP STATION DESIGN CRITERIA (If Applicable) -_ 02T.0305 s MDC (Pump SlatioiWForce Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees), latitude: Longitude: -� 3. Design Ilow of the pump station; millions gallons per day (firm capacity) 4. Operational point(s) ofthe pump(s)' gallons per minute tit— __ feet total dynamic head (TDI-I) 5. Summarize the lorce main to be permitted (for this Pump Station): Size (inches) Length (feel) Material h. Power reliability in accordance with 15A NCAC 02T .0305(h)(l ): ❑ Standby power source or pomp with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(l3)_ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(I )(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule ofthe portable power source or pump. including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 0 4-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): I. Does the project comply with all separations found in 15A NCAC 02T .0305 I & I5A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: L►RMNIM Setback Parameter* Se aration Required Storm sewers and other utilities not listed below (vertical) 24 incites Water maids vertical -water over sewer including in benched trenches 18 incites Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or -round water lowering and surtace drainage ditches 10 feet Anv building foundation 5 feet Anv basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Anv swimming pools 10 feet Final earth grade (vertical) 36 inches i I5A NCAC 02T.0305(R) contains alternatives where separations in 02T.03050 cannot be achieved. **Stream classifications can be identified using the Division's NC Surface Water Classifications webPag_e If noncompliance with 021'.0305(t) or(g). see Section X ofthis application Does the project comply with separation requirements far wetlands? (50 feet ol'separation) ® Yes ❑ No See the Division's draft separation requirements for situations where separation cannot be meet e No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of areas effected 3. Does the project comply %vith all setbacks found in the river basin rules per 1 SA NCAC 02B .0200? ® Yes ❑ No This would include Trout Buffered Streams per I5A NCAC 213.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes ❑ No Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters lnfanrtation can be obtained from the 401 & Buffer Permittim-, Branch 5. Does project comply with I5A NCAC 021'.0105(c)(6) (additional perntitsicertitications)? ® Yes []No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied I'or, or have been obtained. issuance of this pert -nit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwaler management plans, etc_). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per I5A NCAC 02T.040?, "high -priority server" means "any aerial sewer, settler contacting surtace waters, siphon, or sewer positioned parallel to streanibanks that is subject to erosion that undermines or deteriorates the sewer. [:]Yes ® No It yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by (fie permittee or its representative at least once every six -mouths and inspections documented per 15A NCAC 02T.0403(a)(5) or the peruiitee's individual System -Wide Collection permit. DORM: PTA 04-16 Page 4 of 5 X. CERTIFICATIONS: I. Does the submitted system comply with 15A NCAC 021', the tylininmum Desi m Criteria for the Permitting of Pump Stations and I"orce Mains (latest version), and the Gravity Sewer Minimum Design Criteria fittest version) as applicable? ® Yes ❑ No II -No, complete and submit the Variance.Ahernative Design Request application (VADC 10-14) and supporting documents for review. Approi'al of the request is required prior to submittal of the Fast Track AnWication and supporting documents. 2. Professional Engineer's Certification: I, _ _ .'✓_ Q--/<�_ _ �_ _--attest that this application for (Professional Engineer's name from Application Item Ill.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Desi+_n Criteria Ior Gravity Sewers (latest version), and the Minimum Design Criteria for the fast -Track Permitting of Pump Stations and Force Mains (latest version). Althauglt other professionals may have developed certain portions ofthis submittal package. inclusion of these materials under my signature and seal signifies that I have reviewed this [material and !rave judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and I43-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000, as %%ell as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: Applicant's Certification per 15A NCAC 02T .0106(b): (SiL41atut'e Authority's name & title from Application Item 1.3.) ................. _ �I pFESS/0 SEAL C. 13371 i H R VCE � 2.�l���� � 3lc�'!iq that this application for has been rerie+ved by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of - this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land ►vill result in an immediate enforcement action that may include civil penalties, injunctive relief, and"or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-2) 15.6A and 143-215.6I3, any person \%ho knowingly makes any false statement, representation, or certification to any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as ►\ ell as civil penalties up to S25,000 per violation. i� Signature - - - Date: CORM, VTA 04-16 Page 5 of 4 . _tD i Cap}r C Lo?9 Dr azae Tarr�antt 1!� 01��d 5aarr Dxa E'SG5 : Sa fr 5rair T 6 17 Data'E r4 DM= W= EY hrcr rf -rTwr-, ur rr_n.r�� F6ARPJ&WW,J P. 1500 Piney Pl" ga.. suHs 200 rEattd x1 x Aar► D PAvax 3 �t a G SGA' Cuy, Narih Camlina 275111 G NatW� cost r�'Sr I ►EI 57 n a a O M o+ U z A. s , N, CD 5 UP U C •may- cA°c' (bf p ; e lap ti �Itpl�-y li C y 04� S Q g Z c 4y V qc r—)6 ,.' a 77L Q hs r]3 R m�Y U Itj w � o- a�. rr on Y b o- - u w o a '� � U A d � s y a' n io Yn�aG x L1 tt W C {ry}�ca a 'o U i � G i7 3 ire, unpt ul Envirouurcntnl Qualuy APR — 2 44019 State of North Carolina Department of Environmental Quality Raleigh Regional Office Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Fitch Creations, Inc. Project Name f'or which flow is being requested: Fearrington Section X Area D Ph. 2 & 3 Ahwe than um FTSE nrn}, be required jbr ashqle prc jevi if the owmr of fhe 11117P is not respotzsihle jor all pump stations abing the rut,te a 'the prupused ti�>ustclrcrter j1u��. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Fearrington WWTP b. WWTP Facility Permit:`#: NC0043559 All floivs rrre in MGD c. WWTP facility's permitted flow 0.50 (0.270 constructed) d. Estimated obligated flow not yet tributary to the WWTP 0.0499 e. WWTP facility's actual avg. flow 0.165 f. Total flow for this specific request 0.005 g. Total actual and obligated flows to the facility 0.2149 h. Percent of permitted flow used 79.59 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Average Daily Approx. Not Yet Total Current Pump Station Firm Flow** Current Tributary Flow Plus (Name or Capacity, ^ (Firm.1 po, Avg. Daily Daily Flow, Obligated Available Number) MGD MGD Flow, MGD MGD Flow Capacity*** Weathersfield 0.90 0.36 0.14 0,019 0.155 0.205 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of sen•ice. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located beiMeeu the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Fearrington Section X Downstream Permit Number: WQ0040057 Page 1 of 6 FTSL 04-16 III. Certification Statement: I _Roy B. Fitch _ certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the now from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance Nvith local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and I1 plus all attached planning assessment addendums for which I am the responsible party. Signature of this Form indicates acceptance of this wastewater flow. Si�mlr7�f�1f frc•icr] Si��r7cr1 zZ Date Page ? of 6 FTSF 04-16 Entity Names Wage 1 of 1 Elaine F. Marshall Secretary Corporations oCorporatioris Home eimportwd Notice +Corporate Forms eCorporations FAQ eNew Form Notice *'Verify Certification Links •Secretary Of State Home •Business License *Register for E-Procureme •Dept. of Revenue Legislation e1999 Senate Bills no01 Bill Summaries •Annual Reports 1997 &Corporations 1997 •Other Legislation Search 9By Corporate Name OF -or New Corporation •By Registered Agent Online Orders DSfart An Order North Carolina DEPARTMENT OF THE SECRETARY OF STATE PO Box M22 Raleigh. NO 2762"6M (919)807 2000 Corporation Names Name Fitch Creations, Inc, Business Corporation Information SOSI D: 0053322 Status: Current -Active Date Former[: 4/10/1961 Citizenship:'Domestic State of Inc.: NC Duration: Perpetual Registered Agent Agent Name: Registered Office Address: Registered Mailing Address: Date: 7/1012002 Document Filings N( NC Dept of Environmental Quality APR - 2 2019 Raleigh Regional Office Principal Offi Fitch Jr. Roy B Address: 2000 Fearrington Principal Mai Village Center Address: Pittshoro NC 27312 2000 Fearrington Village Ctr Pittsboro NC 27312 Bar -Coded Forms For questions or comments about the North Carogna Secretary of State's web site, please send e-mail to Wei For questions or comments conceming the Corporatians Divtslon, please send e-mail to CoMotations http://www secretary.state.nc.us/Corpo tions/soSWCorp.asp?4652064 07/10/2002 .NORTH CARoLwA PUBLIC STAFF UTrI MES COMMISSION January 16, 1996 r Mr. Allen Keith 219 E. Chatham Street Cary, Forth Carolina 27511 Re: Fearrington Village Chatham County Dear Sir: NC -Dept of Enylro�men,�+ pub APR - 2 ZQ19 r, Raleigh Regio"I off - le This lettbr is to certify that Fearrington Utilities has been granted a Certificate or. Public Convenience and Necessity to Provide sewer utility service in the above subdivision under Docket No. W-661, Sub 3. This utility company is under.the jurisdiction of and subject to the requirements of the North Carolina Utilities Commission. If we can, be of further assistance to you, please do not hesitate to contract this office. AL: sw Sincerely, io),db A iZ-) Andy Lee, Director Public Staff - Water Division nay cam ex==xRemuch 7334" ma ma 733-2M � 0 7 a° A=wn ft abrtssmarSMV&= E3=We NA=d rM faux 733-�279 733-M7 M2t67 7 -AM 733WI0. P.O. Box 2MO - Mcigk North &m1iM 2762 ZM - F= (9t9) �133-StSG - 4 M iter < April 25, 2007 Mr. Roy B. Fitch, President Fearrington Utilities 2000 Fearrington Village Pittsboro, NC 27312 Subject: Fearrington Utilities WV\/TP Permit No. NCO043559 Adjusted Daily Sewage Flow Design Rate Chatham County Dear Mr. Fitch: Michael F. Easley, Governor William G Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W Klimek, RE Director Division of Water Quality ��D�ptoFE�ylro APB h���t8' ouarlty 2019 Raleigh Rcgfcnaf Office c On January 19, 2007, the Division of Water Quality (Division) received a request from your consulting engineer, Diehl & Phillips, for an adjustment to the daily sewage flow design rates. This adjustment would apply to all permitted but not yet tributary connections and all future connections tributary to this facility in accordance with 15A NCAC 02T .0114(f). A flow adjustment to 70 gallons per day per bedroom was requested. The information provided was reviewed by the Division's Raleigh Regional Office, and additional information was provided by your engineer to the Raleigh Regional Office dated February 23, 2007 and March 28, 2007. In accordance with 15A NCAC 02T .0114(f)(2), the Raleigh Regional Office has evaluated all the submitted data and considered other factors including weather conditions during the data period of November 2005 through October 2006, monitoring data for this facility and an analysis of flow reduction data for other facilities comparable to Fearrington. Based on the data submitted, the Division hereby approves the use by Fearrington Utilities for the collection system described in Permit No. WQCS00238, and the treatment plant described in Permit No. NC0043559, an adjusted daily sewage design flow rate of 250 gallons per day per 1 to 3 bedroom single family dwelling, with an additional 70 gallons per day per each bedroom over 3 bedrooms, effective immediately. In granting this flow reduction, please be advised that the Division will not reissue any outstanding permits made prior to this flow reduction request. If reissued permits are desired, a permit modification request with the appropriate fee must be submitted for each permit to be so modified. Flow allocation and tracking files maintained by the Raleigh Regional Office will be updated for any flow being shown as not yet tributary to the WWTP. Future sewer extension applications should be made using the reduced flow amounts stated above. All other aspects of the permitting process remain unchanged, and all applications l ,oM,� Carolina North Carolina Division of Water Quality 1628 Mail Service Center Raleigh, NC 27699-1628 Phone (919) 7914200 Customer Service Internet vmu ncwaterquality.org location. 3800 Barrett Drive Raleigh, NC 27609 Fax (919) 571 4718 1-877-623-6748 An Equal Opportunity/Afnnative Action Employer— 50%RecydedllD% Post Consumer Paper y Mr. Roy B. Fitch 'Fearrington Utilities Page 2 must be in compliance with the statutes, rules and regulations, and minimum design criteria as certified by the owner and engineer. Without regard to this or any other flow reduction either requested or granted, at no time shall the flow to this wastewater treatment facility exceed the limits defined in the NPDES permit for this facility, nor exceed the capacity of the sewers downstream of any new sewer extension or service connection. If you have any questions regarding this adjustment to the daily sewage flow design rates, or require any additional information, please contact Barry Herzberg at (919) 7914249, or by e- mail to barry.herzberg@ncmail.net. Sincerely, for Alan W. Klimek, P.E., Director Division of Water Quality by Charles Wakild, P.E. Surface Water Quality Supervisor Raleigh Regional Office Cc: John F. Phillips, PE; Diehl & Phillips, 219 East Chatham Street, Cary, NC 27511 Chatham County Health Department RRO SWP, SL, SB, BH RRO, Fearrington WWTP File, NC0043559 Deborah Gore, PERCS Unit Jim McKay, NPDES East DIEHL & PHILLIPS, P.A. CONSULTING ENGINEERS 1500 Piney Plains Road Suite 200 Cary, North Carolina 27518 Telephone (919) 467-9972 Fax (919) 467-5327 March 29, 2019 WILLIAM C. DIEI IL, P.E, JOI IN r. PI IILLIPS, P.C. ALAN R. KEITH, P.E. Non -Discharge Permitting Unit NC Dept of Environmental Quality Division of Water Quality NC DENR APR r 2 206 1628 Mail Service Center Raleigh, NC 27699-1617 Rdeigh Regional Office Re: Fast Track Sewer System Extension Application Gravity Sewer Extensions to serve Section X Area D Phase 2 & 3 Fearrington P.U.D. Chatham County Dear Reviewer: Enclosed for your review are the following for the referenced project: 1. Original and one copy of Gravity Sewer Extension Form 2. Flow Tracking Form (FTSE) 3. $480.00 Review Fee We request that you approve the proposed permit application. There are 21 residential units associated with the project. The flow associated with the project is 5,250 gallons per day. Should you have questions or require further information, please contact our office. Sincerely, Diehl & Phillips, P.A. Alan R. Keith, P.E. Cc: R.B. Fitch