HomeMy WebLinkAbout20190622 Ver 1_SF-030217_HYD_SMPv2.07_20180531_20190510I-lighway North Carolina Department of Transportation
Stot'tnYt✓afet
Highway Stormwater Program \
STORMWATER MANAGEMENT PLAN
(Version 2.07; Released October 2016) FOR NCDOT PROJECTS
WBS Element: 17BP.10.R.140 TIP No.: SF-030217 County(ies): ANSON Page 1 of 1
General Project Information
WBS Element:
178P.10.R.140 ITIP Number: SF-030217 Project Type: Bridge Replacement Date: 5/31/2018
NCDOT Contact:
Marc T Shown
Contractor / Desi ner:
STV Engineers, Inc. / Shirshant Sharma
Address:
1020 Birch Ridge Drive
Raleigh, NC 27610
Address:
900 West Trade Street, Ste. 715
Charlotte, NC 28202
Phone:
919 707 6751
Phone:
704 816-2556
Email:
mshown ncdot. ov
Email:
Shirshant.Sharma
stvinc.com
Cit (Town:
Wadesboro
Count ies :
Anson
River Basins :
Yadkin -Pee Dee
ICAMA County?
I No
Wetlands within Project Limits?
No
Project Description
Project Length (lin. miles or feet):
0.08 Surrounding Land Use: IRural, wooded, agricultural
Proposed Project
Existing Site
Project Built -Upon Area ac.
0.3 ac.
0.2 ac.
Typical Cross Section Description:
Roadway: Two 10' lanes, paved shoulders
Bridge: Two 10' lanes, no shoulders
Approach: Two 10' lanes, 4' shoulders
Annual Avg Daily Traffic (veh/hr/day):
Design/Future: 190 Year: 2025
Existing: 190 Year: 2013
General Project Narrative:
(Description of Minimization of Water
Quality Impacts)
STV Engineers, Inc. is providing engineering services for the bridge replacement project on SR 1654 (Morton Road) over Lanes Creek. The existing bridge is a 135.3'(1 @45'2",
2@45'1") triple -span bridge with a steel plank deck on I -beams and mass concrete abutments and interior bents. The proposed structure will be a 170' long bridge with a span
arrangement of 1 @50' (21" cored slab), 1 @70' (24" cored slab) and 1 @50' (21" cored slab). The proposed roadway alignment over the bridge is the same as the existing bridge
alignment. Overall drainage patterns will be maintained. There are roadside ditches that flow towards the bridge on either side of the structure. The drainage pattern of the
ditches are being maintained and the drainage from the bridge is being discharged into the ditches. Deck drains will be needed for the proposed structure to prevent spreading
inside the travel lane. The deck drains will not discharge directly to the jurisdictional stream. Deck drains will be located over the floodplain bench area as shown in the BSR.
Impervious dikes with special stilling basins shall be used to contain the sediment laden water and prevent it from being discharged into the stream.
Waterbody Information
Surface Water Body (1): Lanes Creek
NCDWR Stream Index No.:
13-17-40-(12)
NCDWR Surface Water Classification for Water Body
Primary Classification:
Class C
Supplemental Classification:
None
Other Stream Classification:
None
Impairments:
None
Aquatic T&E Species?
No Comments:
NRTR Stream ID:
Buffer Rules in Effect: N/A
Project Includes Bridge Spanning Water Body?
Yes
Deck Drains Discharge Over Buffer? INo
Dissipator Pads Provided in Buffer? N/A
Deck Drains Discharge Over Water Body?
INo
(If yes, provide justification in the General Project Narrative)
(If yes, describe in the General Project Narrative; if no, justify in the
General Project Narrative)
(If yes, provide justification in the General Project Narrative)