Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0004774_Report_20190424
41IN DUKE James Wells ENERGY® Vice President Environmental,Health and Bidet Programs&Environmental Sciences 526 South Church Street Mail Code EC13K Charlotte,NC 28202 (980)373-9646 April 24, 2019 Via Overnight Mail 41 Corey Basinger 4p -N`�G�!/ Mooresville Regional Office Regional Supervisor R 29 Z� R North Carolina Department of Environmental Quality �7%j�r 19 Division of Water Resources P®r�n�t,lh�e�r�/es Water Resources - Water Quality Regional Operations on 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Bob Sledge North Carolina Department of Environmental Quality Water Quality Permitting Program Division of Water Resources 1617 Mail Service Center Raleigh, NC 27699-1617 Subject: Report Under Special Order by Consent—EMC SOC WQ S 18-004 Duke Energy Carolina, LLC—Buck Steam Station NPDES Permit NC0004774 2018 Annual Seep Survey Report Dear Messrs. Basinger and Sledge: On behalf of Duke Energy Carolinas, LLC (DEC), I am submitting to you the Buck Steam Station Annual Seep Report summarizing the findings of the comprehensive survey and to begin addressing decanting impacts on the seeps as required by the Buck Steam Station NPDES Permit NC0004774 Special Order by Consent (SOC), SOC No. S 18-004 Section 2.c.3). As required by the SOC, I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. Messrs. Basinger and Sledge April 24, 2019 Page 2 Please direct any questions concerning the Buck Steam Station NPDES Permit NC0004774 SOC No. S 18-004 to Elizabeth Glenn at (980) 373-0530 and to Chris Hallman at (980) 373-7892 relative to the annual seep inspection report. S. rely, James ells Vice Pr sident,Environment, Health& Safety- Program and Environmental Sciences Duke Energy Attachment: Buck Steam Station 2018 Annual Seep Survey CC: Richard Baker, Duke Energy Elizabeth Glenn, Duke Energy Chris Hallman, Duke Energy Dale Wooten, Duke Energy Paul Draovitch, Duke Energy Matt Hanchey, Duke Energy Terra 2018 ANNUAL SEEP REPORT BUCK STEAM STATION EMC SOC WQ S18-004 1555 DUKEVILLE ROAD SALISBURY, NC 28146 APRIL 2019 PREPARED FOR DUKE ENERGY CAROLINAS, LLC 4fraN DUKE ENERGY. CAROLINAS • Erin N. K' y, EIT Project Engineer l 7 Perry drep, N #2453 Pro' ct Manager 2018 Annual Seep Report April 2019 Buck Steam Station, Duke Energy Progress,LLC SynTerra TABLE OF CONTENTS SECTION PAGE 1.0 INTRODUCTION 1 2.0 FINDINGS 3 2.1 General Observations 3 2.2 Impact of Decanting 3 2.3 Changes to Seep Status 3 3.0 REFERENCES 4 LIST OF FIGURES Figure 1 SOC Locations and Inspection Areas LIST OF TABLES Table 1 SOC Locations and Descriptions-2018 Inspection LIST OF APPENDICES Appendix A Photographs Page i 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Progress,LLC SynTerra LIST OF ACRONYMS AOW Areas of Wetness CCR Coal Combustion Residuals EMC Environmental Management Commission SOC Special Order by Consent Page ii 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Progress,LLC SynTerra 1.0 INTRODUCTION On November 20, 2018, Kathy Webb (NC L.G. #2546) of SynTerra inspected the Buck Steam Station(Buck or the Site) for existing and potential new areas of wetness (AOWs). The aforementioned activities were performed in accordance with North Carolina EMC Special Order by Consent WQ#518-004. That Special Order by Consent (SOC) describes inspection requirements as follows: Duke Energy shall conduct annual comprehensive surveys of areas down gradient of ash basins identifying new seeps, and documenting the physical characteristics of previously documented seeps. All examinations of seeps must include identification of seeps by approximate latitude and longitude and date-stamped digital photographs of their appearance.A report summarizing the findings of the surveys, including a section analyzing the effect decanting of the basin(s)has on seep flows, accompanied by copies of the photographs noted above ("Annual Seep Report"), shall be submitted to DWR in conjunction with submittal of the April 30 quarterly report noted in 2(c)(2)above. This Annual Seep Report must list any seep that has been dispositioned (as described below) during the previous year, including an analysis of the manner of disposition. All locations listed in Table 1 of the SOC were observed and documented with photographs during the inspection. General inspection observations include: • No previously unidentified seeps were observed during the inspection. • No notable changes to seep status were observed during this inspection. • Decanting had not begun at the time of this inspection. Page 1 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Progress,LLC SynTerra Inspection Details Weather during and preceding the inspection was dear. Temperatures ranged from approximately 50 to 60 degrees F. No rainfall occurred in the three days before the inspection according to the onsite rain gage,but heavy rainfall from the week prior to the inspection was evident with standing water lingering in areas of poor drainage. The inspector reviewed previous AOW inspection reports and the weekly dam safety inspection reports for each ash basin. Scott Harris(system owner) conducted the ash basin dam safety inspections and prepared the reports. Mr. Scott Harris and Mr. Max Gardner were interviewed concerning recent rainfall, construction/stabilization projects associated with the ash basins, and general site conditions in and around the ash basins. Observations from the dam safety inspection reports were consistent with observations made during the SOC inspection. The inspection included observations in the following areas, (Figure 1): • North and east of Ash Basin Cells 2 and 3, along the Yadkin River • Along the Tributary located east of the Ash Basin Cells 2 and 3. • Along the Tributary located west of the Ash Basin Cell 1 • Between the Steam Station and Ash Basin Cell 1, along the dam The inspection scope of work also included a review of the areas identified as downgradient of the basin. SOC locations are shown on Figure 1. Observations noted during the inspection are summarized on Table 1. Photographs of each seep location are induded in Appendix A. Page 2 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Progress,LLC SynTerra 2.0 FINDINGS 2.1 General Observations Inspection Observations are shown for each seep in Table 1. Details include: • The inspector observed a culvert with a small amount of flow north of former S- 07 along the access road to the steam plant. Flow was assumed to be storm water from the northeast of the culvert and not associated with the Ash Basin. • The new retention pond construction was underway and ponded water from a construction area onsite. • The inspector observed notable flow near a cove of the Yadkin River. This change in flow appeared to be due to the clearing of trees and vegetation at the top of the hill associated with the new discharge line. • AOW 13 exhibited wet conditions but no flow, consistent with past inspections. Flow was noted at the culvert outlet to the Yadkin River. 2.2 Impact of Decanting Decanting of the ash basin at Buck had not yet begun at the time of this inspection. 2.3 Changes to Seep Status Ms. Webb inspected each seep to evaluate whether it should be dispositioned in accordance with the SOC. The requirements for dispositioning a seep are as follows: For purposes of this Special Order, "dispositioned"includes the following: (1) the seep is dry for at least three consecutive quarters; (2) the seep does not constitute, and does not flow to, waters of the State or Waters of the United States for three consecutive quarters; (3) the seep is no longer impacted by flow from any coal ash basin as determined by the Director of DWR in accord with applicable law and best professional judgment; or(4) the seep has been otherwise eliminated(e.g., through an engineering solution). If a seep that has been dispositioned through drying up reappears in any subsequent survey, such a seep will no longer be deemed dispositioned and can be subsequently re-dispositioned as specified above. Non-constructed seeps described in paragraph 1(h) of this SOC cannot be dispositioned through option (2)above. Seeps dispositioned during 2018 were done so at the time of the SOC issuance. Table 1 lists those seeps dispositioned and the basis for disposition. Seeps identified as dispositioned at Buck are S-02, S-03, S-06, S-07,S-09, S-10, S-12, S-13, and S-16. These dispositioned seeps will continue to be inspected and evaluated for any change in flow conditons. In general, there was no change in status of the dispositioned seeps and no change in status of remaining seeps observed during this inspection. Page 3 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Progress,LLC SynTerra 3.0 REFERENCES North Carolina Department of Environmental Quality. (2018). Special Order by Consent EMC SOC WQ S18-004. Page 4 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Progress,LLC SynTerra FIGURE N 1 z { .. .....� l- ,..., .., , 1 , ' / . ...,, ' .. '-'-'''' - —1 ,',- 4,, .„--.7,2.. .. .,,,,,, ,,,,,_,,.... :_toi.„,., ,,,....-,-.1-,L_., - ; I D1 , . , , " , ,I -`, 't f. +R'• ¢ • 4 t LEGEND ° . ' NPDES CONSTRUCTED SEEP(APPROXIMATE) t .. t' NON-CONSTRUCTED SEEP(APPROXIMATE) • R,..S .., DISPOSITIONED SEEP(APPROXIMATE) t`(r �.. 4 ' f•, I ._ ° —ASH BASIN WASTE BOUNDARY ,--; -—-ASH BASIN COMPLIANCE BOUNDARY raJ —ASH STORAGE BOUNDARY DUKE ENERGY PROGRESS BUCK FYFYFY tE' "'PLANT SITE BOUNDARY K. STREAM(AMEC NRTR 2015) . - .� {` .s.. S ECAL ORDER BY CONSENT(SOC)INSPECTION AREA I. •....' .. �. L. e . SPECIAL ORDER BY CONSENT(SOC)LOCATIONS ARE DESCRIBED IN EMC SOC Wo SIR-00A. ('®—" `•1 etz, NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM(NPDES)LOCATIONS ARE DESCRIBED IN PERMIT NC000.1374 -• Y' • I AERIAL WAS COLLECTED ONAOCTOBERINED 125,201fi`E EARTH PRO ON MARCH I9,2018 r. S ej ` I i _ NATURAL RESOURCES TECHNICAL REPORT(NRTR)PREPARED BYAMEC FOSTER +' •.,I,.,®.. i WHEELER INC..MAY 29.2015. A C + WSP SURVEY CONDUCTED APRIL 11.201<. a T �- • DRAWING HAS BEEN SET WITH A PROJECTION OF NORTH CAROLINASTATE PLANE C•' gfA.} ":/ORDINATE SYSTEM An3200(NAOS)1. I DDD FIGURE 1 j • �` ✓jt� GRAPHIC 5GLI TRRI SOC LOCATIONS AND INSPECTION AREAS T+� synTerra IRS"VERSTREE SUITE220 BUCK STEAM STATION 4� ✓ „ .riw1.✓r�Y.'. ,.wA0 4 gh �', w. UNA 29E01 GREF L E SOUTH CARD PHONE (_DUKE DRAWN BY I AIRTZ +LDRER DATE D„2,i2015 SALISBURY,NORTH DUKE ENERGY OCAROLINA d �, ,tire •a .B, ENERGY s 2018 Annual Seep Report April 2Q19 Buck Steam Station,Duke Energy Progress,LLC SynTerra TABLE TABLE 1 SOC LOCATIONS AND DESCRIPTIONS-2018 INSPECTION BUCK STEAM STATION DUKE ENERGY CAROLINAS,LLC,SALISBURY,NC Location Coordinates Receiving Receiving Facility Sample ID Waterbod Waterbody Description SOC Monitoring Interim Action Levels Notes from Inspection Latitude Longitude y Classification Seep to UT that flows north to Yadkin River in Buck 5-01 35.70914 -80.36044 UT to Yadkin River WS-V approximately 2 foot wide channel.Located Monitoring at point prior NA-2B Standards Apply Water was observed to be clear and flowing. northeast of the active ash basin,north of to any tributary flow to UT Leonard Road. Located northeast of the active ash basin, Buck S-02. 35.709414 -80.359441 UT to Yadkin River WS-V north of Leonard Road.Flows north to Yadkin NA-Seep Dispositioned NA-Seep Dispositioned Steady moderate flow within well defined River via approximately 4.5 foot wide stream. tributary to Yadkin River.Water is clear. From sampling-No CCR impacts. Located northeast of the active ash basin, Buck S-03. 35.710382 -80.360097 UT to Yadkin River WS-V north of Leonard Road.Flows north to Yadkin NA-Seep Dispositioned NA-Seep Dispositioned Steady moderate flow within well defined River via approximately 8.5 foot wide stream. tributary to Yadkin River.Water is clear. From sampling-No CCR Impacts. Minor amounts of orange aerobic Seep to approximately 2 foot wide channel, bacteria/floc/iron-oxidation on substrate.Flow located northeast of the active ash basin,north Monitoring at point prior Hardness 200 mg/L Buck S-04 35.711273 -80.360796 UT to Yadkin River WS-V of Leonard Road.Stream flows east to Yadkin to entering Yadkin River Mercury 0.1 pg/L infiltrates underground and re-emerges twice River. along channel before flowing overland towards Yadkin River. • Seep to short UT below storm water culvert Monitoring at established Orange aerobic bacteria/floc/iron-oxidation on Buck 5-05 35.712239 -80.364595 UT to Yadkin River WS-V near toe of ash basin dam.UT may receive Duke Energy S-05 pH 6-10 S.U. substrate.No continuous overland flow to Yadkin flow from S-14 prior to reaching Yadkin River. monitoring site Hardness 200 mg/L River. Approximately 4 foot wide stream located Steady moderate flow emerging as spring from north of active ash basin,east of stream bank of tributary to Yadkin River.Orange Buck S-06. 35.711971 -80.369032 UT to Yadkin River WS-V decommissioned Buck Steam Station facility. NA-Seep Dispositioned NA-Seep Dispositioned aerobic bacteria/floc/iron-oxidation apparent on Flows north toward Yadkin River.From substrate and biofllm on the water. sampling-No CCR impacts. Approximately 3.5 foot wide stream,located No flow observed,water stagnant.Minor Buck S-07. 35.708704 -80.378637 UT to Yadkin River WS-V northwest of the active ash basin,west of NA-Seep Dispositioned NA-Seep Dispositioned amounts of orange aerobic bacteria/floc/iron- Dukeville Road.Flows northwest to Yadkin oxidation apparent on rip rap substrate. River.From sampling-No CCR Impacts. Seep to approximately 1 foot wide channel, Monitoring at established Flow within Yadkin River tributary where crushed Buck 5-O8 35.708212 -80.378345 UT to Yadkin River WS-V located northwest of the active ash basin,west Duke Energy S-08 Hardness 200 mg/L culvert emerging from beneath Dukeville Road of Dukeville Road.Flows northwest to Yadkin monitoring site. joins stream tributary. River. Monitoring of UT to Yadkin Clear steady flow with orange aerobic Instream Monitoring to evaluate potential River at established Duke Hardness 200 mg/L / oc/ apparent on Buck S-09" 35.705502 -80.375677 UT to Yadkin River WS-V impacts from 5-11 and 5-17. Energy S-09 monitoring bacteria Fl iron-oxidation Location substrate. Approximately 2 foot wide stream,located Clear stream emerging from spring/seepage area * west of the active ash basin,west of Dukeville NA-SeeDispositioned NA- Dispositioned with low to medium flow.Sandysubstrate with Buck S-10 35.702188 -80.376455 UT to Yadkin River WS-V Road.Flow is to Yadkin River.From sampling- p Seep p rocky cobbles in the channel bottom. No CCR impacts. sOC Tables_ALL_Final_2019_04_17 Page I of 2 TABLE 1 SOC LOCATIONS AND DESCRIPTIONS-2018 INSPECTION BUCK STEAM STATION DUKE ENERGY CAROLINAS,LLC,SALISBURY,NC Location Coordinates Receiving Facility Sample ID Receiving Latitude Longitude Waterbody Waterbody Description SOC Monitoring Interim Action Levels Notes from Inspection Classification Seep discharge from terracotta pipe to ri ra ed channel on north dike wall of ash NA-Monitoring Clear steady flow with orange aerobic Buck S-11 35.707126 -80.374034 UT to Yadkin River WS-V pp D Established per Terms of See Page 4 of Buck SOC bacteria/floc/iron-oxidation a basin.Flow conveyed to UT to the Yadkin NPDES Permit Document pparent on River. culvert/terracotta pipe. Buck S-12** 35.707429 -80.373661 UT to Yadkin River WS-V Channeled seep through a terracotta pipe.Pipe Seep eliminated via engineering repairs.Area has been plugged;discharge eliminated. NA-Seep Dispositioned NA-Seep Dispositioned inspected,but seep no longer exists. Minimal AOW with no flow.Identified as a Buck S-13** 35.711931 -80.364056 UT to Yadkin River WS-V damp area near pump house;no sufficient NA-Seep Dispositioned NA-Seep Dispositioned No flow observed.Glossy flow to perform sampling.Any flow would biofilm apparent. move to adjacent storm drain. Low flow seep near storm water culvert just Monitoring at established Buck S-14 35.712171 -80.364817 UT to Yadkin River WS-V above S-O5 location.Any flow will move to UT Duke Energy S-O5 See S-OS Minor amounts of orange aerobic to Yadkin River near 5-05 monitoring site bacteria/floc/Iron-oxidation on rip-rap substrate. Low flow seep downgradient of S-05 location. Monitoring at established Buck S-15 35.7123 -80.3644 UT to Yadkin River WS-V Seep flows to braided,short reach UT prior to Duke Energy S-05 See S-05 Orange aerobic bacteria/Floc/Iron-oxidation on entering Yadkin River monitoring site substrate.Biofilm apparent on water surface. • Static area of wetness along west dike wall of Buck S-16** 35.7044 -80.3746 UT to Yadkin River WS-V ash basin.Flow would drain toward S-09 Seep eliminated via engineering repairs.Area sampling site.Location has been repaired NA-Seep Dispositioned NA-Seep Dispositioned inspected,but seep no longer exists. based on no area of wetness. Filter blanket discharge from west dike wall of NA-Monitoring Buck S-17 35.7058 -80.3753 UT to Yadkin River WS-V ash basin.Flow conveyed to UT to the Yadkin Established per Terms of See Page 4 of Buck SOC Clear slow flow with no orange aerobic River. NPDES Permit Document bacteria/floc/iron-oxidation apparent. NOWPrepared by.Of Checked by.gic •-Location previously Investigated as a seep.Monitoring has not Indicated the presence of coal combustion residuals. "-Seep disposltionad via repair end/or non-flowing condition to potentially reach Waters of the U.S.,or other,as noted.Monitoring shad be conducted at the approximate locations indicated on the attached site map. All monitoring shall be conducted per the requirements found In Attachment c of this Order. pg/L-micrograms per liter 28-15A NCAC 02L.0202 Standard CCR-Coal Combustion Residuals mg/L-mllograms per liter NA-Not Applicable NPDES-National Pollutant Discharge System S.U.-standard Units SOC-Special Order by Consent UT-Unnamed Tributary SOC Tables_ALL_nnal_2019_04_17 Page 2 of 2 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Progress,LLC SynTerra APPENDIX A PHOTOGRAPHS 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Carolinas,LLC SynTerra irm.....Ina' NE E . SE l0 oU • 9(� 120 150 1 • 1 . 1 • I • I • 1 • I • I • 1 • I • I • I • I • I • P ©99°E(T) ••35°42'32"N,80°21'37"W x32.8ft A 644ft .v:, ,. . .,4,,,,:,. .4, ,, ,.. , , 4 '.:?:.,,,_,9,x.: - '-'--" 4. ,ti,.,fers, • - '•'4i: >It S „°► .4 . - • y5r• .4 k. • x. ♦i ) 1 • X [jft r.: , S-01 View of SOC sample location facing east. SE S l SW 1SL 18(1 . 210 240 27. 3: •. 1 • I • I • I • I • i • 1 • I • I • I • I • I • I • I t 1 ©202°S(T)) E 35°42'33"N,80°21'33"W t32.8ft ♦688ft I r:- A 'P v y • 1 :T ...1.- 1 I :2' let 4.sJ _.. , ti ,i . - . 1' !' x. 4'It*.--.. r € qi ' f 1 T�;r , 1110M 1. i• ..Y a1-..., e TJAtt.. 1.. yt ?� c "1 a /f .ti q• 11 i• � r �{�St t ?a R rid • ,Y ;,, , >' F x- 20v 2018.0J 49 00 S-02 View of dispositioned seep facing south southwest. 1 x 4.10 synTerra 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Carolinas,LLC SynTerra k 0113°SE(T) 4 35°42'37"N,80°21'35'W x16.4ft ♦663ft zi' I I 1 -• y _- �x�'we i / - l 1 �1 y • �513 1 r. 1. T-' �ei � �4 4 .,`t" of l rt_ Y , , '► .fli e E • . - t . _� � tx. . , . _ ,..eieNe4447,f. .,, a . , il _ { `' u 1 f•� 1 •y r. It- 1 20,ov 201 0. »:I • S-03 View of dispositioned seep location facing east southeast. SW W NW 210 240 270 300 330 • 1 • I • I • I • 1 • I • 1 • I,• I • I • I • I • 1 • I .263°W(T) 0 35°42'39"N,80°21'39"W t32.8ft ♦703ftt tfr, a# +..i-4:"144tti 12't • . ♦ ' - k. I' .� .. , 1', r - r -0 1 , -\ I 4.(6, � Y 'r �-r s • . ra ;. . 4,4r4°,11 ,i4,:: -.: S-04 View of SOC sample location facing west. synTerra 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Carolinas,LLC SynTerra 1 NW 1.0 N NE _ I • 1 •300 1 • 1 • 1 • 1 • 1 • ' • 0 1 • 1 1 • 1 • I • 1 • 1 • 1 ®350°N(T) •.35°42'43"N,80°21.51"W±16.4ft A 688ft 1t • V. _ . ,--i- ...?,C7 ' '"N• .0., r quuq �F y 4 .. :,, , , .t. c; ,0 -, ,- , i ,t:i - -., . oP ". 1 tir t3,.�F �.- 2.' 1r .�' fly.-: • f 5'" *Ill f ,-i1 20 r1oi 2` d1ik Ib;3sv S-05 View of SOC sample location facing north. , 1 g'' SO. 1 W ,N' 180 210 11 1 I 1 • i • I ,;-. 1 •®246°SW(T) *35°42'43"N,80°22'8"W±32.8ft A 659ft t s ; -.. r Jam-""� J 1 .11 f r �i '4 R }� ' :N, fib.:.- P :,•„., ,.. '4 S 1 asp' r.. II;4.4 r i 1.' � 'r iVii � '�' 7* .ENO 1 ` ', 20,;. -+ • 1.1.33:17 P r S-06 View of dispositioned seep location facing west southwest. 1 L" synTerra • 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Carolinas,LLC SynTerra S SW W 1) ,1I 2,1,0 2:,, I • . • . • 1 • 1 • 1 • 1 • 1 • 1 • 1 • 1 • 1 • 1 • 1 • 1 ®210°SW(T) •35°42'31"N,80°22'43"W±16.4ft ♦652ft y -- 'f+••\ /!.• • r . t .' I' i"'e4.'w •./SKf •� 1''1±.-'•'; • I • + r 4 �' �l4. ,, • °,',"., ..,"A, . -.\"r" /t4 At; „ A>.•s*.t• , l .444-1_4 .."' + S-% %.,. .d • t (r 1 . 4 f.. « :. :� <",i` + v t.. rv.i-,5 4t,...e r..sk4fzi.c Ati...- ...,.• i. t.,,,.,• ., ,..4.;....i.s4t.::1,,,/ ..‘.:,,.,,-,i a ! ¢ , i i.4'. 44) • ft !• ' 4' .J • ..- ` t .,......-S,20 t o 4.Sr42-:37:3 t S-07 View of dispositioned seep location facing south southwest S SW W N +en 210 Zan ro 300 • I • 1 • 1 • 1 • 1 • I • 1 • 1 • 1 • I • 1 • 1 • 1 • 1 . ®245°SW(T) • 35°42'29"N,80°22'42"W±16.4ft ♦603ft • ram. eye "ig.. ti .' < ''''. ♦r Y•' . . :),. . ..,,,::.,.. ,s. -_-,,..--,...-,%.1,., - ...-4f-,,,-f.-•. ' . y ♦, ' b r l , ! :• ...'.;,, 4'k., . ,., r_4.-14.44 li f''..-41. 4et• ., -=';-.. .:°:16,IS '‘'.: ' ';I.I. 'lit..41/4'• `tip,'"k"••: 4.,,_ S-08 View of SOC sample location facing west southwest. L•o y synTerra 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Carolinas, LLC SynTerra 1 E SE S 1 Fo ix. •- ,80 • , • , • , . , • , • , • , • , • , • , • 1 • I • 1 • 0124°SE(T) e)35°42'19"N,80°22.32"W±16.4ft ♦633ft I A01$ ) sg ri.-A 's o 4 • y �•. 9 ;:i 4 r ' ,' 20 Nov 201$i(2 55:41 S-09 View of dispositioned seep location facing southeast. i 1 r t' / /el r • , `t r% e. , ^ •` {.^ a+l ..% 1. . ,, it 4,41f ,.. „./4" .'., r r,pp z. m a r. t', ``1 .,ti ? kill,"'; "• ' 9,i 4 • , S-10 View of dispositioned seep location facing west. synTerra I • 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Carolinas,LLC SynTerra SW W NW N lad 270 ,DO 330 G • I • I • I • I • I • I • I • I • I • I • I • I • I • I ®292°W(T) 35°42'25"N,80°22'26"W s16.4ft ♦674ft ;f _ 3 +s .:t s • stir.._.}. - \ -.` M :f ' , _• . yppfs � HCo�OCJi* 'i• � O74 `/a,+ : as : . A te17r s .j' 1 O Nov,201:.11:50:5• S-11 View of SOC sample location facing west southwest. [ S Sv, W I • i • I • I • I • 1 • I • 1 • I • I • 1 • i • 1 • 1 • 116, C 230°SW(T) 135°42'26"N,80°22'25"W t16.4ft ♦729ft p tit��� d p� ,f/ B S Noti;f s,. s' i' •' ` 'h s 1��. i ./ M ' 2 / rt % `ram 1 R 4 tIPY2 u 1.8 • i 4'. 5-12 View of dispositioned seep location facing southwest. Seep was eliminated via engineering repairs. 0 synTerra ° 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Carolinas,LLC SynTerra `. _ _ S i SW 180 210 240 1 1 • 1 • 1 • I • 1 • 1 ! 0 194°S(T) 6 35°42'42"N,80.2t50"W-116.4ft ♦658ft .rya 4.' -r` 77 y, ,4 j -f. . ..,r I_ °br.� art a OS - "� .et t1 yam... ,f • - ' yy,s.�y Y 4 r / a s - r, %. •:•�'r -Ix:It, t ft':, i ce S-13 View of dispositioned seep sample location facing south. .A•inioni S ' ISw W 150 180 21.' 210 270 I • I • 1 • 1 • 1 • 1 • I • I • I • 1 • I • I • I • I • :217°SW(T) *35°42.43"N,80°2152"W f16.4ft ♦657ft 1 s'")11-,0 ,. t - 'r ''.,• . .4i.do*Or. '- i 1 - • --, '.3.--. 1. .A3,4: ; _v t. :.-i. ,' _ - 1� j I`; i 9' s r -•-.4:::07,&4.1). ' 1.-.. , `i ..q4. _ , ,., - J. i1 .• • li,...t. 4-, n...•• -6- 't ,s e` �, :•` r lit f • , i , , — 1~ � s 4 S-14 View of SOC sample location facing southwest. 0 synTena 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Carolinas,LLC SynTerra , * IIV4 .fit, • S. - I { 7 i,c1 3 f .. rp • 4 `f,r +:r +� . V ' S-15 View of SOC sample location facing west. Seep is monitored at S-05. No photo provided.Seep was eliminated via engineering repairs. S-16 0 synTena 2018 Annual Seep Report April 2019 Buck Steam Station,Duke Energy Carolinas,LLC SynTerra � �4' < if } I •` �_Y 0* `,; fix• / �- C 7 �a`4 • p� � \ fit. r .. I < NC000.71< / 41 4;':',. -4 ,„ ,,,, am,m•s nr s ` :_....t. 1,,,_.. , .,.4,v%:, .+ f �s- r•d= i �e { f Y' . +'' r icy • i-°A Y 1- 1 _.1-i t 7, .• ,, ,. ;; 'r t a F d'r f �f� • `•.J."�`,Cl�<�lt Y!� AG. .. _y g � ! z:.. f i S-17 View of NPDES seep monitoring location facing west, synTerra