Loading...
HomeMy WebLinkAbout20190586 Ver 1_U-5888 100 Percent Combined_structure_20190503DocuSign Envelope ID: BF2BAAFD-39FB-4132-B494-A8D1 El E55B93 6' co cs U X4 O Q4 H C T7 Prepared in the Office of.• Prepared for: DESIGN DATA PROJECT LENGTH ETHERILL DIVISION OF HIGHWAYS ADT 2021 = 7,800 ENGINEERING DIVISION 14 ADT 2040 = 9,000 1223 Jones Franklin Rd. Raleigh, N.C. 27606 License No. F-0377 Bus: 919.851.8077 Fax: 919.851.8107 253 Road� SylvaeNC, 28779 �bster �DQ�%� G Q 4, 2018 STANDARD SPECIFICATIONS K = 9 % D = 50 % LENGTH ROADWAY TIP PROJECT U-5888 = 0.240 MILES GREG S. PURVIS, PE tpa ° * /o T = 6 TOTAL LENGTH TIP PROJECT U-5888 = 0.240 MILES PROJECT ENGINEER V = 40 MPH e Q * TTST = 2% DUAL = 4% LETTING DATE: JOHN A. DILWORTH, PE F U N C . CLASS = February 18, 2020 PROJECT DESIGN ENGINEER MINOR ARTERIAL 11ICDOT CONTACT. J. SCOTT MILLER, III NOTE: —Ll— AND —L2— USED FOR PROJECT LENGTH DIVISION 14 DDC ENGINEER DocuSign Envelope ID: BF2BAAFD-39FB-4132-B494-A8D1ElE551393 �o �N BM4o BENCHTIE NAIL IN 24" LEELAND CYPRUS9 STA. 9+29.52 -Y5 124.88' RT., ELEV. 26130479 N6604059 E815800 0 o0g o0 0 oho I � I - 0 0 I I z // o �I O / c 0 (J) \ q i EXISTING RCBC / z 2 (;� 10' x 8' 1 121 0 -30 -00 1 � � I PROPOSED \ 15" RCP PROPOSED DOUBLE 11' X 9' RCBC CB (DROP IN TOP / \ \ OF RCBC) 6- 50'-0" EL. 2613.0 ± EL. 2613.0 ± DRAWN BY e J. PENDERGRAFT DATE e 11-18 CHECKED BY e J.A. DILWORTH DATE e 1-19 Sm CV V) 0 I— m". — STA. 14+99.00 -Y4- CLASS I RIP RAP (ROADWAY DETAIL & PAY ITEM) (TYP.) Cam. �j LOCATION SKETCH FOR UTILITY INFORMATION, SEE UTILITY PLANS AND SPECIAL PROVISIONS. 50'-0" EL. 2614.0 ± -Y4- 50'-0" EL. 2 616. 0 - PROFILE ALONG C CULVERT 50'-0" Z EL. 2 616. 0 ± \ S 4 TON _\ cR \ EEC TOTAL STRUCTURE QUANTITIES CULVERT EXCAVATION LUMP SUM FOUNDATION CONDITIONING MATERIAL 176 TONS CLASS A CONCRETE BARREL 66 2.897 CY/FT 257.8 C.Y. WINGS 58.3 C.Y. HEADWALLS 2.6 C.Y. SILLS 5.6 C.Y. END CURTAIN WALLS 2.9 C.Y. TOTAL 327.2 C.Y. REINFORCING STEEL BARREL 38134 LBS, WINGS 4218 LBS. TOTAL 42352 LBS. GALVANIZED RAILS 164.88 LIN. FT. NOTES ASSUMED LIVE LOAD ---------- HL-93 OR ALTERNATE LOADING. DESIGN FILL TO BOTTOM OF TOP SLAB 2.00' (MIN.) AND 5.19' (MAX) FOR OTHER DESIGN DATA AND NOTES SEE STANDARD NOTE SHEET. 3"0 WEEP HOLES INDICATED TO BE IN ACCORDANCE WITH THE SPECIFICATIONS. CONCRETE IN CULVERTS TO BE POURED IN THE FOLLOWING ORDER. 1.WING FOOTINGS AND FLOOR SLAB INCLUDING 4" OF ALL VERTICAL WALLS. 2. THE REMAINING PORTIONS OF THE WALLS AND WINGS FULL HEIGHT FOLLOWED BY ROOF SLAB AND HEADWALLS. THE RESIDENT ENGINEER SHALL CHECK THE LENGTH OF CULVERT BEFORE STAKING IT OUT TO MAKE CERTAIN THAT IT WILL PROPERLY TAKE CARE OF THE FILL. DIMENSIONS FOR WING LAYOUT AS WELL AS ADDITIONAL REINFORCING STEEL EMBEDDED IN BARREL ARE SHOWN ON WING SHEET. TRANSVERSE CONSTRUCTION JOINTS SHALL BE USED IN THE BARREL, SPACED TO LIMIT THE POURS TO A MAXIMUM OF 70 FT. LOCATION OF JOINTS SHALL BE SUBJECT TO APPROVAL OF THE ENGINEER. STEEL IN THE BOTTOM SLAB MAY BE SPLICED AT THE PERMITTED CONSTRUCTION JOINT AT THE CONTRACTOR'S OPTION. EXTRA WEIGHT OF STEEL DUE TO THE SPLICES SHALL BE PAID FOR BY THE CONTRACTOR. FOR CULVERT DIVERSIONS DETAILS AND PAY ITEM, SEE EROSION CONTROL PLANS. A 3 FOOT STRIP OF FILTER FABRIC SHALL BE ATTACHED TO THE FILL FACE OF THE WING COVERING THE ENTIRE LENGHT OF EXPANSION JOINT. FOR SUBMITTAL OF WORKING DRAWINGS SEE SPECIAL PROVISIONS. FOR FALSEWORK AND FORMWORK, SEE SPECIAL PROVISIONS. FOR CRANE SAFETY,SEE SPECIAL PROVISIONS. FOR GROUT FOR STRUCTURES,SEE SPECIAL PROVISIONS. AT THE CONTRACTOR'S OPTION, HE MAY SPLICE THE VERTICAL REINFORCING STEEL IN THE INTERIOR FACE OF EXTERIOR WALL AND BOTH FACES OF INTERIOR WALL ABOVE LOWER WALL CONSTRUCTION JOINT. THE SPLICE LENGTH SHALL BE AS PROVIDED IN THE SPLICE LENGTH CHART SHOWN ON THE PLANS. EXTRA WEIGHT OF STEEL DUE TO THE SPLICES SHALL BE PAID FOR BY THE CONTRACTOR. AT THE CONTRACTOR'S OPTION HE MAY SUBMIT, TO THE ENGINEER FOR APPROVAL, DESIGN AND DETAIL DRAWINGS FOR A PRECAST REINFORCED CONCRETE BOX CULVERT IN LIEU OF THE CAST -IN -PLACE CULVERT SHOWN ON THE PLANS. THE DESIGN SHALL PROVIDE THE SAME SIZE AND NUMBER OF BARRELS AS USED ON THE CAST -IN -PLACE DESIGN.FOR OPTIONAL PRECAST REINFORCED CONCRETE BOX CULVERT,SEE SPECIAL PROVISIONS. THE EXISTING STRUCTURE CONSISTING OF A 10'x8'DOUBLE BARREL REINFORCED CONCRETE BOX CULVERT 43'-6"LONG ALONG CENTERLINE OF CULVERT AND LOCATED AT PROPOSED STRUCTURE SHALL BE REMOVED. THE EXISTING CULVERT IS PRESENTLY NOT POSTED FOR LOAD LIMIT. NATIVE MATERIAL BETWEEN SILLS/BAFFLES IN THE CULVERT SHALL PROVIDE A CONTINUOUS LOW FLOW CHANNEL. NATIVE MATERIAL CONSISTS OF MATERIAL THAT IS EXCAVATED FROM THE THE STREAM OR FLOODPLAIN AT THE PROJECT SITE DURING CONSTRUCTION. ONLY MATERIAL THAT IS EXCAVATED FROM THE STREAM BED MAY BE USED TO LINE THE LOW FLOW CULVERT BARREL. RIP -RAP MAY BE USED TO SUPPLEMENT THE NATIVE MATERIAL IN THE HIGH FLOW CULVERT BARREL(S),IF RIP -RAP IS USED TO LINE THE HIGH FLOW CULVERT BARREL(S),NATIVE MATERIAL SHOULD BE PLACED ON TOP TO FILL VOIDS AND PROVIDE A FLAT SURFACE FOR ANIMAL PASSAGE. NATIVE MATERIAL IS SUBJECT TO APPROVAL BY THE ENGINEER AND MAY BE SUBJECT TO PERMIT CONDITIONS. ROADWAY DATA GRADE POINT ELEV. 2 STA 14+99.00 -Y4- = 2626.35 BED ELEV STA 14+99 00 -Y4- - 2614 15 ROADWAY SLOPES = 2:1 HYDRAULIC DATA_ DESIGN DISCHARGE = 1100 CFS FREQUENCY OF DESIGN FLOOD = 25 YEAR DESIGN HIGH WATER ELEVATION = 2623.0 DRAINAGE AREA = 1.93 SO. MI. BASE DISCHARGE (0100) = 1500 CFS BASE HIGH WATER ELEVATION = 2624.6 OVERTOPPING FLOOD DATA OVERTOPPING DISCHARGE = 1720 CFS FREQUENCY OF OVERTOPPING FLOOD = 100+ YEAR * OVERTOPPING FLOOD ELEVATION = 2625.5 OVERTOPPING OCCURS AT STA. 14+29 -Y4- +/- AT THE ROADWAY CENTERLINE ENGINEER OF RECORD 4/30/2019 ®0"tl... NN XIIII XIIX ddpyddyyyy aaa°° \A C A RD fs S E A L _ o. 22072 iz -tj.R. gill nno \°�a0aaaa D1 S'gnedl/by: I/ A�n Ariiwr 1�1.,1/ E6213622 26 �j ETHERILL ENGINEERING 1223 Jones Franklin Rd. DOCUMENT NOT CONSIDERED FINAL Raleigh, N.C. 6 85180 Bus: 919 851 8077 UNLESS ALL SIGNATURES COMPLETED LICENSE NO. F0377 I HEREBY CERTIFY THESE PLANS ARE THE AS -BUILT PLANS PROJECT No. U-5888 HAYWOOD COUNTY STATION: 14+99-00 -Y4- SHEET 1 OF 11 REPLACES BRIDGE NO. 460 1 STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION RALEIGH BARREL STANDARD DOUBLE 11 FTo X 9 FT. CONCRETE BOX CULVERT 1210-30'-00"SKEW NOVEMBER 1990 REVISIONS SHEET N0. NO. BY: DATE: NO. BY: DATE: C 1 LI TOTAL lJ SHEETS L, 11 DocuSign Envelope ID: BF2BAAFD-39FB-4132-B494-A8D1 El E55B93 LOAD FACTORS-. V) LOAD AND RESISTANCE FACTOR RATING (LRFR) SUMMARY FOR REINFORCED CONCRETE BOX CULVERTS STRENGTH I LIMIT STATE MOMENT SHEAR O w = = w m 0CD 0 1-- w 0 1-- 0 mw 0 0 mw+ � ZZ H H U Q X J C:� ?` U Q w0 U Q L_0 Z W J LL Q OJT LL W LL W J J u I- _�0- O� Q �0 Z ii 10 CD Z O Z Z LLI ZWz Q LLI CD Z O Z Z LLI ZWz Q LLI Z W W H C- Z 1-- 0 H un LLI l =' W I- = H =' LLI => => > LLI = L d H w 0 Z Q 00 Z �--I Q� Z 0 > U " Q I- Q x O W W J>- cn w LLI " LLI J Q x O W W J>- Cn w LLI " LLI -10 J > �.� UJ ��.� 1-- -1 LL_ m W1-- c�JW m LLI�_ c�JW U HL-93 (INVENTORY) N/A 01 1.06 -- 1.75 1.53 1 TOP SLAB 5.00 1.06 1 BOTTOM SLAB 10.95 DESIGN HL-93 (OPERATING) N/A 1.38 -- 1.35 1.98 1 TOP SLAB 5.00 1038 1 BOTTOM SLAB 10095 LOAD RATING HS-20 (INVENTORY) 36.000 �2 1.21 43.56 1.75 1.70 1 TOP SLAB 5.00 1.21 1 BOTTOM SLAB 10.95 HS-20 (OPERATING) 36.000 1.57 56.52 1.35 2.20 1 TOP SLAB 5.00 1.57 1 BOTTOM SLAB 10095 SNSH 13.500 3.09 41.72 1.40 3.09 1 TOP SLAB 5.00 3.58 1 BOTTOM SLAB 10.95 SNGARBS2 20.000 2.42 48.40 1.40 2.89 1 TOP SLAB 5.00 2.42 1 BOTTOM SLAB 10.95 w SNAGRIS2 22.000 2.21 48.62 1.40 3.09 1 TOP SLAB 5.00 2.21 1 BOTTOM SLAB 10.95 H SNCOTTS3 27.250 1064 44.69 1.40 2.01 1 TOP SLAB 5.00 1.64 1 TOP SLAB 10.50 V) w " SNAGGRS4 34.925 1.39 48.55 1.40 2.14 1 BOTTOM SLAB 11.67 1.39 1 BOTTOM SLAB 10.95 CD H SNSSA 35.550 1.37 48.70 1.40 2.02 1 BOTTOM SLAB 11067 1.37 1 BOTTOM SLAB 10.95 V) SNS6A 39.950 1e37 54.73 1.40 2.01 1 BOTTOM SLAB 11.67 1.37 1 BOTTOM SLAB 10.95 LEGAL SNS7B 42.000 1.28 53.76 1.40 1.92 1 BOTTOM SLAB 11.67 1.28 1 BOTTOM SLAB 10.95 LOAD RATING TNAGRIT3 33.000 1.48 48.84 1.40 2.22 1 BOTTOM SLAB 11.67 1.48 1 BOTTOM SLAB 10.95 Q TNT4A 33.075 1.47 48062 1.40 2.23 1 BOTTOM SLAB 11.67 1.47 1 BOTTOM SLAB 10.95 17 TNT6A 41a600 1.37 56.99 1.40 2.03 1 BOTTOM SLAB 11067 1.37 1 BOTTOM SLAB 10095 v TNT7A 42.000 1.28 53.76 1.40 1.91 1 BOTTOM SLAB 11.67 1.28 1 BOTTOM SLAB 10.95 C TNT7B 42.000 1.40 58.80 1.40 2.06 1 BOTTOM SLAB 11067 1.40 1 BOTTOM SLAB 10.95 U TNAGRIT4 43.000 O3 1.14 49.02 1.40 1.77 1 BOTTOM SLAB 11.67 1.14 1 BOTTOM SLAB 10.95 TNAGTSA 45.000 1.27 57.15 1.40 1.95 1 BOTTOM SLAB 11e67 1.27 1 BOTTOM SLAB 10e95 TNAGTSB 45.000 1.16 52.20 1.40 1.74 1 BOTTOM SLAB 11.67 1.16 1 BOTTOM SLAB 10095 11'-n,, (TYP ) BOX 1 BOX 2 LRFR SUMMARY (LOOKING DOWNSTREAM) DESIGN LOAD RATING FACTORS LOAD TYPE MAX FACTOR MIN FACTOR DC 1.25 0.90 DW 1.50 0.65 EV 1.30 0.90 EH 1.35 0.90 ES 1.35 0.90 LS 1.75 -- WA 1.00 -- NOTE-0 RATING FACTORS ARE BASED ON THE STRENGTH I LIMIT STATE. COMMENTS-, 10 20 30 40 J(D CONTROLLING LOAD RATINGI ODESIGN LOAD RATING (HL-93) O2 DESIGN LOAD RATING (HS-20) O3 LEGAL LOAD RATING * SEE CHART FOR VEHICLE TYPE PROJECT No. U-5888 HAYWOOD COUNTY STATION- 14+99-00 -Y47 SHEET 2 OF 11 DocuSign Envelope ID: BF2BAAFD-39FB-4132-B494-A8D1 El E55B93 COCO00 Ln 4- #5 G1 BARS 2 3"CTSo 01 FOR ROADWAY WIDTH, SEE ROADWAY PLANS 3" 3" ROADWAY FILL SLOPE 2a1 -Y4- WING SLOPE / / FOR 201 FILL / // / / H- -o 0- - - I 3-#8 S2 BARS QI o w H � �zm o 15" 2S RCP-IV9 � mo J #4 B2 BARS FILL FACE m ��a w � H � #4 B1 BARS STREAM FACE �' �a � # U — — — — N — - — — — — — — — — — — — — — — 3" 0 WEEP HOLES Cb 10'-0" ± CTSo 0 3-#8 S2 BARS EXTERIOR WALL 15" 0 RCP DETAIL FOR REINFORCEMENT SEE SHEET 4 OF 11 CULVERT SECTION #5 A101 BARS ETC. (b 6" CTSo 6�1*5 A100 BARS (b 6" CTSo BOTTOM OF ROOF SLAB BOTTOM OF ROOF SLAB #6 A301 BARS ETC. 2 6" CTSo 6" #6 A300 BARS Z 6" CTSo 2/ 3-#8 S2 BARS 2 5" CTSo BOTTOM OF ROOF SLAB ROADWAY FILL SLOPE 2.1 1'-3„ ------------------ •• 3-#8 S2 BARS Ob 5" CTSo BOTTOM OF ROOF SLAB `9 �—% WING SLOPE FOR 201 FILL CONST. JTo 6" GRADE CD U w o CD `D a #4 B3 EA.FACE N V) STAGGERED U ELEV. 2614.15 a CONST. JTo # ,L, 3-#8 S2 BARS (;� 5" CTSo TOP OF FLOOR SLAB INTERIOR WALL ORMAL TO ROADWAY TOP OF ROOF SLAB TOP OF ROOF SLAB W1 -Y4- \?0 o �i cp_ 4- #5 G1 BAR 2 3"CTSo IN HEADWAL * * FOR 2'-0" W x 3'-0" L FORMED OPENING IN ROOF SLAB OPENING DETAIL, SEE SHEET 4 OF 11 #5 A2 BARS O,b 6" CTSo CORNER BARS EA. EXT. WALL ( SEE BARREL SECTION ) #4 B1 BARS 2 10" CTSo STREAM FACE #4 B2 BARS 2 6" CTS. FILL FACE aOHW - Hc ST\A . 14+99000 zQ�- l QJ� U) Uw LL v) 0o 1210-30'-00" LLOm _— — — — — — — — — — — — m - — — — — — — — — — — — — — — n CD 0Q rn 0 m m Q Q O Q U U O /) U U w17O # . S L wJn OQ Oa V) <°20 2,-0"W x 3-0"L << FORMED OPENING M M FOR CATCH BASIN u ~o w mu� # -- ---7r—T—i T-------— — — — — — — / / / W3 15" 0 RCP -IV THRU EXTERIOR WALL #5 Al BARS 2 6" CTSo CORNER BARS EA. EXT. WALL ( SEE BARREL SECTION ) 5 2- 6 z E W2 _0„ �? o �s 900 6% 600 300 10'-01, SKEW TRIANGLE it rt �t � it 1'-0" #4 B3 BARS C�D 1'—O" CTSo — EACH FACE STAGGERED IN INT. WALL \e0 0 CULVERT 3-#8 S2 BARS Ob 5"CTSo TOP OF FLOOR SLAB #5 A200 BARS Z 6" CTSo S L wJn OQ Oa V) <°20 2,-0"W x 3-0"L << FORMED OPENING M M FOR CATCH BASIN u ~o w mu� # -- ---7r—T—i T-------— — — — — — — / / / W3 15" 0 RCP -IV THRU EXTERIOR WALL #5 Al BARS 2 6" CTSo CORNER BARS EA. EXT. WALL ( SEE BARREL SECTION ) 5 2- 6 z E W2 _0„ �? o �s 900 6% 600 300 10'-01, SKEW TRIANGLE it rt �t � it 1'-0" #4 B3 BARS C�D 1'—O" CTSo — EACH FACE STAGGERED IN INT. WALL \e0 0 CULVERT 3-#8 S2 BARS Ob 5"CTSo TOP OF FLOOR SLAB #5 A200 BARS Z 6" CTSo 6" 1*5 A201 BARS ETC. Z 6" CTSo TOP OF FLOOR SLAB -1 loop TOP OF FLOOR SLAB 1*6 A400 BARS Z 6"CTSo 6" #6 A401 BARS ETC. 2 6" CTSo BOTTOM OF FLOOR SLAB BOTTOM OF FLOOR SLAB 36'-6" LENGTH OF CULVERT = 89'-0" PART PLAN - ROOF SLAB- Ln T) �n Ln Ln 11 27'-8g/6„ Ln Ln INLET END ELEVATION NORMAL TO SKEW LOOKING DOWNSTREAM 27'-89/6„ Ln 1 OUTLET END ELEVATION NORMAL TO SKE LOOKING UPSTREAM 0 CV 0 0 N PROJECT No. U-5888 HAYWOOD COUNTY STATION- 14+99000 -Y4- SHEET 3 OF 11 STD- NOo CB332 DocuSign Envelope ID: BF2BAAFD-39FB-4132-B494-A8D1 El E55B93 00 00 00 Ln BARREL REINFORCING STEEL BAR NO SIZE TYPE LENGTH WEIGHT BAR NO SIZE TYPE LENGTH WEIGHT Al 356 5 1 6'-41, 2352 A300 150 6 STR 23'-8" 5332 A2 356 5 1 5'-9 2135 A301 2 6 STR 23'-2" 70 A302 2 6 STR 22'-3" 67 A303 2 6 STR 21'-5" 64 A100 150 5 STR 23'-8" 3703 A304 2 6 STR 20'-7" 62 A101 2 5 STR 23'-2" 48 A305 2 6 STR 19'-8" 59 A102 2 5 STR 22'-3" 46 A306 2 6 STR 18'-10" 57 A103 2 5 STR 21'-5" 45 A307 2 6 STR 17'-11" 54 A104 2 5 STR 20'-7" 43 A308 2 6 STR 17'-1" 51 A105 2 5 STR 19'-8" 41 A309 2 6 STR 16'-3" 49 A106 2 5 STR 18'-10" 39 A310 2 6 STR 15'-41, 46 A107 2 5 STR 17'-11" 37 A311 2 6 STR 14'-61, 44 A108 2 5 STR 17'-1" 36 A312 2 6 STR 13'-8" 41 A109 2 5 STR 16'-3" 34 A313 2 6 STR 12'-9" 38 A110 2 5 STR 15'-4" 32 A314 2 6 STR 11'-111, 36 A111 2 5 STR 14'-6" 30 A315 2 6 STR 11'-01, 33 A112 2 5 STR 13'-8" 29 A316 2 6 STR 10'-2" 31 A113 2 5 STR 12'-9" 27 A317 2 6 STR 9'-41, 28 A114 2 5 STR 11'-11" 25 A318 2 6 STR 8'-5" 25 A115 2 5 STR 11'-01, 23 A319 2 6 STR 7'-7" 23 A116 2 5 STR 10'-2" 21 A320 2 6 STR 6'-8" 20 A117 2 5 STR 9'-41, 19 A321 2 6 STR 5'-10" 18 A118 2 5 STR 8'-5" 18 A322 2 6 STR 5'-0" 15 A119 2 5 STR 7'-7" 16 A323 2 6 STR 4'-1" 12 A120 2 5 STR 6'-8" 14 A324 2 6 STR 3'-3" 10 A121 2 5 STR 5'-101, 12 A325 2 6 STR 2'-4" 7 A122 2 5 STR 5'-01, 10 A123 2 5 STR 4'-11, 9 A400 150 6 STR 23'-8" 5332 A124 2 5 STR 3'-3" 7 A401 2 6 STR 23'-2" 70 A125 2 5 STR 2'-4" 5 A402 2 6 STR 22'-3" 67 A403 2 6 STR 21'-5" 64 A200 150 5 STR 23'-8" 3703 A404 2 6 STR 20'-7" 62 A201 2 5 STR 23'-2" 48 A405 2 6 STR 19'-8" 59 A202 2 5 STR 22'-3" 46 A406 2 6 STR 18'-10" 57 A203 2 5 STR 21'-5" 45 A407 2 6 STR 17'-11" 54 A204 2 5 STR 20'-7" 43 A408 2 6 STR 17'-1" 51 A205 2 5 STR 19'-81, 41 A409 2 6 STR 16'-3" 49 A206 2 5 STR 18'-101, 39 A410 2 6 STR 15'-4" 46 A207 2 5 STR 17'-11" 37 A411 2 6 STR 14'-6" 44 A208 2 5 STR 17'-1" 36 A412 2 6 STR 13'-8" 41 A209 2 5 STR 16'-3" 34 A413 2 6 STR 12'-9" 38 A210 2 5 STR 15'-4" 32 A414 2 6 STR 11'-11" 36 A211 2 5 STR 14'-6" 30 A415 2 6 STR 11'-01, 33 AM 2 5 STR 13'-8" 29 A416 2 6 STR 10'-2" 31 A213 2 5 STR 12'-9" 27 A417 2 6 STR 9'-41, 28 A214 2 5 STR 11'-11" 25 A418 2 6 STR 8'-5" 25 A215 2 5 STR 11'-01, 23 A419 2 6 STR 7'-7" 23 A216 2 5 STR 10'-2" 21 A420 2 6 STR 6'-8" 20 A217 2 5 STR 9'-4„ 19 A421 2 6 STR 5'/ 10;' 18 A218 2 5 STR 8'— 5 18 A422 2 6 STR 5 —0 15 A219 2 5 STR 7'-7" 16 A423 2 6 STR 4'-11, 12 A220 2 5 STR 6'-8" 14 A424 2 6 STR 3'-3" 10 A221 2 5 STR 5'-10" 12 A425 2 6 STR 2'-4" 7 A222 2 5 STR 5'-0" 10 A223 2 5 STR 4'-1" 9 A224 2 5 STR 3'-3" 7 A225 2 5 STR 2'-4" 5 BAR NO SIZE TYPE I LENGTH WEIGHT B1 214 4 STR 11'-1" 1584 B2 356 4 STR 8 —4 1982 B3 177 4 STR 11'-11, 1310 C1 1 364 1 4 1 STR 1 23'-8" 1 5755 D1 15 6 STR 2'-7" 58 D2 27 6 STR 1'-7" 64 E1 16 1 5 STR 4'-0" 67 Q F1 12 8 STR 12'-6" 401 G1 1 8 1 5 1 STR 1 27'-4" 1 228 S2 1 12 1 8 1 STR 1 27'-4" 1 876 REINFORCING STEEL 38,134 LBS 2'-0" W x 3'-0" L FORMED OPENING FOR CATCH BASIN #8 F1 TOP & BOTTOM OF SLAB (TYPo) A100 & A300 BARS (TYPo) 4" (TYPo) 4" TYPo 00 # cn 0a a �m co U # cn rr 0a �m 3" CL. 2'-0" 3„ CLe OPENING PLAN - FORMED OPENING IN ROOF SLAB 15" QS RCP —IV #5 E1 EA. FACE (TYPo) ELEV. - 15" 0 PIPE THRU EXTERIOR WALL DETAIL NOTE - THE 15"0 PIPE THRU THE EXTERIOR WALL OF THE CULVERT AND 2'—O" W x 3'—O" L FORMED OPENING IN ROOF SLAB IS SHOWN IN IT'S APPROXIMATE LOCATION, THE FINAL LOCATION SHALL BE VERIFIED BY THE ENGINEER PRIOR TO POURING THE CULVERT WALLS AND ROOF SLAB. FIELD BEND AND/OR CUT At, C1, B1 & B2 BARS ONLY AS NECESSARY TO AVOID CONFLICT WITH THE PROPOSED 15"0 RCP. CUT A100 & A300 BARS TO PROVIDE 2"CLEARANCE TO FORMED OPENING.SEE DRAINAGE SUMMARY SHEET FOR INVERT ELEVATION° 24'-0" RIGHT ANGLE SECTION OF BARREL THERE ARE 91 "C" BARS IN SECTION OF BARREL. IST. JTo Pa) PROJECT No. U-5888 HAYWOOD COUNTY STATION- 14+99000 -Y4- SHEET 4 OF 11 DocuSign Envelope ID: BF2BAAFD-39FB-4132-B494-A8D1 El E55B93 —Y4— z a aD U co::Z:- CXD cj_ Ln N I , O Ln �N �m � O N Nrn I N cl� � W1 120 °—00'-00" 2'-0" SILL (TYP. BARREL 2) STA.14+99000 —Y4- BARREL 2 121 °-30'-00" 1200-00'-00" /-- C CULVERT 2'-0" SILL i i I ~1`0" SILL 2'-0" SILL i dd 2'-0" SILL i i I 1'-0" SILL 2'-0" SILL i i I i 2'-0" SILL 1'-0" SILL i I i i I i I i 1'-0" SILL 1'-0" SILL I 1'-0" SILL BARREL 1 1'-0" SILL i 1'-0"SILL i i i i i 1'—O" SILL i i 2'-0" SILL i I i 2'-0"SILL i I I I i 2'-0" SILL i I i 2'-0" SILL mi ►►m i i i i i i i 9 SILLS Cb 10'-0" CTS. ,I, V L_, L X I I I a/ 7F 'L L) 1 /\ u L/ 1 \ I I I o/ INLET ELEVATION LOOKING DOWNSTREAM PLAN - SILL LOCAT SHOWING PLACEMENT OF SILLS CULVERT SILL DETAILS J J J J I --I H 11 1'-01, Cr N J U 2 LAYERS OF 30 LB. ROOFING FELT TO PREVENT BOND (TYP.) SECTION THROUGH SILL DOWELS MAY BE PUSHED INTO GREEN CONCRETE AFTER SLAB HAS BEEN FLOAT FINISHED° SEE "PLAN — SILL LOCATIONS" FOR SILL LOCATIONS FLOW PROJECT No. U-5888 HAYWOOD COUNTY STATION- 14+99-00 -Y4- SHEET 5 OF 11 DocuSign Envelope ID: BF2BAAFD-39FB-4132-B494-A8D1ElE551393 z C� a N L U co c� Ln oLn �N m � O N Nm � N 3" .. 5-#4 Z5 5-#5 Z4 5-#5 Z3 3-#5 Z2 2-#5 Z1 3- BOTTOM OF ND FOOTING PLAN 9 2—#5 Z6 2—#5 Z7 4—#5 Z8 4—#4 Z9 PLAN 9 cI '16 3" BAR TYPES ALL BAR DIMENSIONS ARE OUT TO OUT. O II 2 .o 0 1'-8%4" (: D mQ) 1'-3" 1'-0" T 6" RADo 8" 71 BILL OF MATERIAL BAR N0. SIZE TYPE LENGTH WEIGHT H1 16 #4 STR 17-10" 191 H2 4 #4 STR 12'-4" 33 H3 4 #4 STR 6'-3" 17 H4 28 #4 1 3'-3" 61 H5 4 #4 STR 18'-5" 49 H6 8 #4 STR 9'-4" 50 H7 2 #4 STR 6'-3" 8 H8 2 #4 STR 2'-10" 4 H9 14 #4 2 3'-3" 30 H10 2 #4 STR 10'-2" 14 mo\o N1 1 4 #6 3 1 11'-4" 68 N2 6 #6 3 10'-9" 97 N3 8 #6 3 9'-10" 118 N4 8 #5 3 8'-10" 74 N5 8 #4 3 7'-10" 42 N6 8 #4 3 6'-10" 37 N7 2 #6 3 11'-2" 34 N8 3 #6 3 9'-11" 45 N9 3 #5 3 8'-7" 27 N10 4 #4 3 6'-10" 18 Z CV Z M Z Q Z Ln Z t9 Z Z 00 Z m Z O z Oao Ln m x� (o Ln m oo in Z2 5'-8" 7" Z3 4'-8" 7„ Z4 3'-9" 7" Z5 2'-10" 6" Z6 6'-0" 7" Z7 5'-5" 7" Z8 4'-2'1 7" Z9 2'-10" 6" S1 1 9 1 #6 1 STR 1 6'-0" 1 81 1 T1 6 #5 STR 19'-9" 124 T2 3 #5 STR 11'-3" 35 V1 4 #4 STR 9'-4" 25 V2 6 #4 STR 8'-9" 35 V3 8 #4 STR 7'-9" 41 V4 8 #4 STR 6'-9" 36 V5 8 #4 STR 5'-9" 31 V6 8 #4 STR 4'-9" 25 V7 2 #4 STR 9'-1" 12 V8 3 #4 STR 7'-10" 16 V9 3 #4 STR 6'-6" 13 V10 4 #4 STR 4'-10" 13 Z1 1 4 #5 4 6'-9" 28 Z2 6 #5 4 6'-3" 39 Z3 10 #5 4 5'-3" 55 Z4 10 #5 4 4'-4" 45 Z5 10 #4 4 3'-4" 22 Z6 2 #5 4 6'-7" 14 Z7 2 #5 4 6'-0" 13 Z8 4 #5 1 4 1 4'-9" 20 Z9 4 --jREINFORCING #4 4 3'-4"--j 9 STEEL 1749 LBS FOR 3 WINGS HKo CLASS A CONCRETE 2-#4 3" 4—#4 V6 4—#4 V5 4—#4 V4 4—#4 V3 3—#4 V2 2—#4 V1 3—#4 "\/" RARC C) 1'-(1" f'TC "\/" RARC V7 3-#4 V8 V9 4—#4 V10 3" (;h 1'-W' (TC I i 4 3 WINGS 24.5 CY "N" HAKS 2 1'-0" C I Se ELEVATION 9 DRAWN BY : A.J. KLINK DATE o 1-19 CHECKED BY o J.A. DILWORTH DATE 1-19 rn _ # 00 # CV "N"" BAKS (db 1'-0" C I Se ELEVATION 9 8" TYPICAL WING SECTION DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED ENGINEER OF RECORD 4/30/2019 ®0"ta... XIIIIXIIX ppyppdyyyy aaaa°° N•• C A R 0 ypdq/9B S E A L _ o. 22072 esy�yy��"Xu�ul�nnno \°�a0aaaa ED11"1by:I/ Sig"11 A�n AA.,,l�I.i 6213822 B100 �j ETHERILL ENGINEERING 1223 Jones Franklin Rd. Raleigh, N.C. 27606 Bus: 919 851 8077 Fax: 919 851 8107 LICENSE NO. F-0377 TOTAL 24.5 CY PROJECT No. U-5888 HAYWOOD COUNTY STATION- 14+99000 -Y4- SHEET 6 OF 11 STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION RALEIGH WINGS FOR CONCRETE BOX CULVERT H = 9'-0" 1200 MA M■ oAINE! on pAINE! 4■ SLOPE - 201 SKEW SHEET NO. BY: DATE: C 6 TOTAL SHEETS 11 DocuSign Envelope ID: BF213AAFD-39FB-4132-6494-MD1ElE55B93 _�'-25/c" 5-#6 Z10 11-#6 Z11 12-#5 Z12 12-#5 Z13 12-#5 Z14 12-#4 Z15 11-#4 Z16 10-114 Z17 3-#6 S1* * S1 BARS Ob BOTTOM OF FLOOR SLAB AND FOOTING Z C� Q a� L U i 00 CXD Ln O Ln �N �m � O N Nrn � N PLAN 9, IN nAKJ l4J 'J 1, I Jo IN nAN- ) tv 'J 1, I Jo ELEVATION nW3_ 3" .. PROJECT No. U-5888 HAYWOOD COUNTY STATION- 14+99-00 -Y4- SHEET 7 OF 11 DocuSign Envelope ID: BF2BAAFD-39FB-4132-B494-A8D1ElE551393 BILL OF MATERIAL BAR TYPES BAR N0. SIZE TYPE LENGTH WEIGHT ALL BAR DIMENSIONS ARE OUT TO OUT. H11 20 #4 STR 16'-8" 223 H12 2 #4 STR 24'-G" 33 CD H13 2 #4 STR 8'-6" 11 c9 H14 6 #4 STR 30'-0" 120 H15 2 #4 STR 24'-10" 33 H16 2 #4 STR 8'-9" 12 3 H17 14 #4 STR 3'-3" 30 H18 4 #4 STR 16'-9" 45 H19 4 #4 STR 16'-0" 43 N11 5 #6 3 11'-111, 89 6" RAD. N12 8 #6 3 11'-4" 136 N13 8 #6 3 10'-91, 129 N14 8 #5 3 10'-3" 86 rt 1'-01, N15 8 #5 3 9'-8" 81 8" 2" N16 8 #5 3 9'-11, 76 2 N17 8 #5 3 8'-6" 71 N18 8 #5 3 7'-11" 66 N19 8 #5 3 7'-5" 62 N20 8 #5 3 6'-101, 57 Z10 6'-10" 8" LA N21 8 #5 3 6'-4" 53 �' "V" BARS S1 3 #6 STR 6'-0" 27 STREAM FACE T3 6 #5 STR 32'-11" 206 Ln a "N" BARS V11 4 #4 STR 9'-10'/ 26 0° V12 5 #4 STR 9'-5" 31 = FILL FACE V13 5 #4 STR 8'-11" 30 J V14 5 #4 STR 8'-5" 28 # "Z" BARS `' CONST. JTe rn V15 5 #4 STR 8'-0" 27 V16 5 #4 STR 7'-6" 25 V17 5 #4 STR 7'-1" 24 HKo V18 6 #4 STR 6'-7" 26 q NLV19 6 #4 STR 6'-0" 24 "T" BARS V20 6 #4 STR 5'-6" 22 m V21 6 #4 STR 4'-111, 20 8" V22 7 #4 STR 4'-3" 20 Z10 5 #6 4 7'-6" 56 Z11 11 #6 4 7'-0" 116 TYPICAL WING Z12 12 #5 4 6'-41, 79 Z13 12 #5 4 5'-9" 72 SECTION W 3 Z14 12 #5 4 5'-2" 65 Z15 12 #4 4 4'-6" 36 Z16 11 #4 4 3'-11" 29 Z17 10 #4 4 3'-7" 24 REINFORCING STEEL 2469 LBS FOR 1 WING CLASS A CONCRETE 1 WING 33.8 CY TOTAL 33.8 CY PROJECT NO. U— 5 8 8 8 HAYWOOD COUNTY STATION° 14+99-00 -Y47 SHEET 8 OF 11 ENGINEER OF RECORD 4/30/2019 STATE OF NORTH CAROLINA ®+a' a pp ppppNnIIIIXIIppppppppp DEPARTMENT OF TRANSPORTATION Mp oaaaaa'`N.. CARO 9ye�9e RQLEIGH SEAL WINGS o. 22072 x E FOR 0 q F-tj..- * 1 CONCRETE BOX CULVERT bbsy���"Xu�ul�nnno \°�a0aaaa ED1 S'gnedlI/Iby: II/I H — g / _ 0 " SLOPE = 2 01 j6213822692i L AIL, 1D1.,1o,4LI I �JIII/ 43/ 1200 SKEW \ E �j ETHERILL ENGINEERING REVISIONS SHEET NO. 1223 Jones Franklin Rd. NO. BY: DATE: NO. BY: DATE: C 8 27606 DRAWN BY A.J. KLINK DATE 2-19 Raleigh,N.C.1807 DOCUMENT NOT CONSIDERED FINAL Bus: 9198518/07 TOTAL Fax: 919 851 8107 SHEETS CHECKED BY , B.C. HUNT DATE : 2-19 UNLESS ALL SIGNATURES COMPLETED LICENSE NO.F-0377 2 11 rl z CV z M z � z L(� z z f` z OD z CT� z CV z CV z \N L� O O rn � CV � O L� � � a� o� oo i` � � � �n � Z11 6'-4" 8" Z12 5'-9" 7" Z13 5'-2" 7" Z14 4'-7" 7" Z15 4'-0" 6" Z16 3'-5" 6" Z17 3'-1" 6" 00 00 00 Ln z C� N L U 00 co:z' CCID V I I M O Ln �N O m � O N Nrn � N DocuSign Envelope ID: BF2BAAFD-39FB-4132-B494-A8D1 El E55B93 i u CO CO CO Ln Z C� Q a LD U i co co L I , Ln O Ln �N �rn � O N Nrn � N PLAN OF INLET END ELEVATION OF INLET END LOOKING DOWNSTREAM (WINGS UNFOLED) PROJECT No. U-5888 HAYWOOD COUNTY STATION- 14+99-00 -Y4- SHEET 9 OF 11 DocuSign Envelope ID: BF2BAAFD-39FB-4132-B494-A8D1 El E55B93 PL CO CO CO Ln Z C� Q a LD U i co c CO Q 4) :�D c-) O Ln �N �o N Nrn � N ELEVATION OF OUTLET END LOOKING UPSTREAM (WINGS UNFOLDED) DETAIL 'A' PROJECT No. U-5888 HAYWOOD COUNTY STATION- 14+99-00 -Y4- SHEET 10 OF 11 DocuSign Envelope ID: BF2BAAFD-39FB-4132-B494-A8D1 El E55B93 NOTES, CO CO CO Ln Z C� Q a� L U X) j � Ln �N �m � O N Nrn I N cl� � CONSTRUCT PROPOSED STEEL PIPE RAIL 11/2"DIAMETER SCHEDULE 40 PLAIN END GALVANIZED STEEL PIPE MEETING THE REQUIREMENTS OF ASTM A53a EMBEDED PIPE RAIL INTO PROPOSED HEADWALLS AND WINGS AS SHOWN ON THE PLANS AND GROUT INTO PLACE.FOR GROUT, SEE SPECIAL PROVISIONS° REPAIR GALVANIZING IN ACCORDANCE WITH SECTION 1076 OF THE NCDOT STANDARD SPECIFICATIONS° WELD IN ACCORDANCE WITH ARTICLE 1072-18 OF THE STANDARD SPECIFICATIONS° FOR GALVANIZED RAILS,SEE SPECIAL PROVISIONS. POST TO E CENTERED = HEADWALL`. a INSET 'A' �66=16111 ""'"` ELEVATION OF RAIL AT HEADWALLS POST TO CENTERED WINGS 101 INSET 'B' 00 ET 'A' HEADWALL C'rr T K IFIT\/ TnI I A I I A Vni IT rnn PAY ITEM GALVANIZED RAILS 164.88 LIN. FT. PROJECT No. U-5888 HAYWOOD COUNTY STATION- 14+99-00 -Y4- SHEET 11 OF 11 DocuSign Envelope ID: BF2BAAFD-39FB-4132-B494-A8D1ElE551393 DESIGN DATA: SPECIFICATIONS - - - - - - - - - - - - - - - - - A.A.S.H.T.O. (CURRENT) LIVE LOAD - - - - - - - - - - - - - - - - - - -- SEE PLANS IMPACT ALLOWANCE - - - - - - - - - - - - - - - - SEE A.A.S.H.T.O. STRESS IN EXTREME FIBER OF STRUCTURAL STEEL - AASHTO M270 GRADE 36 - - 20.000 LBS. PER SO. IN. - AASHTO M270 GRADE 50W - - 27,000 LBS. PER SO. IN. - AASHTO M270 GRADE 50 - - 27.000 LBS. PER SO. IN. REINFORCING STEEL IN TENSION - GRADE 60 - - - 24,000 LBS. PER SO. IN. CONCRETE IN COMPRESSION - - - - - - - - - - - - 1.200 LBS. PER SO. IN. CONCRETE IN SHEAR - - - - - - - - - - - - - - - - SEE A.A.S.H.T.O. STRUCTURAL TIMBER - TREATED OR UNTREATED EXTREME FIBER STRESS - - - 1,800 LBS.PER SO.IN. COMPRESSION PERPENDICULAR TO GRAIN OF TIMBER - - - - - 375 LBS. PER SO. IN. EQUIVALENT FLUID PRESSURE OF EARTH - - - - - 30 LBS.PER CU.FT. (MINIMUM) MATERIAL AND WORKMANSHIP: EXCEPT AS MAY OTHERWISE BE SPECIFIED ON PLANS OR IN THE SPECIAL PROVISIONS. ALL MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE 2018 "STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES"OF THE N.C.DEPARTMENT OF TRANSPORTATION. STEEL SHEET PILING FOR PERMANENT OR TEMPORARY APPLICATIONS SHALL BE HOT ROLLED. CONCRETE: UNLESS OTHERWISE REQUIRED ON PLANS.CLASS A CONCRETE SHALL BE USED FOR ALL PORTIONS OF ALL STRUCTURES WITH THE EXCEPTION THAT: CLASS AA CONCRETE SHALL BE USED IN BRIDGE SUPERSTRUCTURES, ABUTMENT BACKWALLS, AND APPROACH SLABS; AND CLASS B CONCRETE SHALL BE USED FOR SLOPE PROTECTION AND RIP RAP. CONCRETE CHAMFERS: UNLESS OTHERWISE NOTED ON THE PLANS,ALL EXPOSED CORNERS ON STRUCTURES SHALL BE CHAMFERED 3/4"WITH THE FOLLOWING EXCEPTIONS: TOP CORNERS OF CURBS MAY BE ROUNDED TO 1'/2"RADIUS WHICH IS BUILT INTO CURB FORMS; CORNERS OF TRANSVERSE FLOOR EXPANSION JOINTS SHALL BE ROUNDED WITH A 1/4"FINISHING TOOL UNLESS OTHERWISE REQUIRED ON PLANS;AND CORNERS OF EXPANSION JOINTS IN THE ROADWAY FACES AND TOPS OF CURBS AND SIDEWALKS SHALL BE ROUNDED TO A 1/4"RADIUS WITH A FINISHING STONE OR TOOL UNLESS OTHERWISE REQUIRED ON PLANS. DOWELS: DOWELS WHEN INDICATED ON PLANS AS FOR CULVERT EXTENSIONS,SHALL BE EMBEDDED AT LEAST 12"INTO THE OLD CONCRETE AND GROUTED INTO PLACE WITH 1:2 CEMENT MORTAR. STANDARD NOTES ALLOWANCE FOR DEAD LOAD DEFLECTION,SETTLEMENT, ETC.IN CASTING SUPERSTRUCTURES: BRIDGES SHALL BE BUILT ON THE GRADE OR VERTICAL CURVE SHOWN ON PLANS. SLABS, CURBS AND PARAPETS SHALL CONFORM TO THE GRADE OR CURVE. ALL DIMENSIONS WHICH ARE GIVEN IN SECTION AND ARE AFFECTED BY DEAD LOAD DEFLECTIONS ARE DIMENSIONS AT CENTER LINE OF BEARING UNLESS OTHERWISE NOTED ON PLANS. IN SETTING FORMS FOR STEEL BEAM BRIDGES AND PRESTRESSED CONCRETE GIRDER BRIDGES,ADJUSTMENTS SHALL BE MADE DUE TO THE DEAD LOAD DEFLECTIONS FOR THE ELEVATIONS SHOWN. WHERE BLOCKS ARE SHOWN OVER BEAMS FOR BUILDING UP TO THE SLAB, THE VERTICAL DIMENSIONS OF THE BLOCKS SHALL BE ADJUSTED BETWEEN BEARINGS TO COMPENSATE FOR DEAD LOAD DEFLECTIONS, VERTICAL CURVE ORDINATE. AND ACTUAL BEAM CAMBER. WHERE BOTTOM OF SLAB IS IN LINE WITH BOTTOM OF TOP FLANGES, DEPTH OF SLAB BETWEEN BEARINGS SHALL BE ADJUSTED TO COMPENSATE FOR DEAD LOAD DEFLECTION.VERTICAL CURVE ORDINATE.AND ACTUAL BEAM CAMBER. IN SETTING FALSEWORK AND FORMS FOR REINFORCED CONCRETE SPANS,AN ALLOWANCE SHALL BE MADE FOR DEAD LOAD DEFLECTIONS, SETTLEMENT OF FALSEWORK, AND PERMANENT CAMBER WHICH SHALL BE PROVIDED FOR IN ADDITION TO THE ELEVATIONS SHOWN. AFTER REMOVAL OF THE FALSEWORK. THE FINISHED STRUCTURES SHALL CONFORM TO THE PROFILE AND ELEVATIONS SHOWN ON THE PLANS AND CONSTRUCTION ELEVATIONS FURNISHED BY THE ENGINEER. DETAILED DRAWINGS FOR FALSEWORK OR FORMS FOR BRIDGE SUPERSTRUCTURE AND ANY STRUCTURE OR PARTS OF A STRUCTURE AS NOTED ON THE PLANS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL BEFORE CONSTRUCTION OF THE FALSEWORK OR FORMS IS STARTED. REINFORCING STEEL: ALL REINFORCING STEEL SHALL BE DEFORMED. DIMENSIONS RELATIVE TO PLACEMENT OF REINFORCING ARE TO CENTERS OF BARS UNLESS OTHERWISE INDICATED IN THE PLANS. DIMENSIONS ON BAR DETAILS ARE TO CENTERS OF BARS OR ARE OUT TO OUT AS INDICATED ON PLANS. WIRE BAR SUPPORTS SHALL BE PROVIDED FOR REINFORCING STEEL WHERE INDICATED ON THE PLANS. WHEN BAR SUPPORT PIECES ARE PLACED IN CONTINUOUS LINES. THEY SHALL BE SO PLACED THAT THE ENDS OF THE SUPPORTING WIRES SHALL BE LAPPED TO LOCK LEGS ON ADJOINING PIECES. STRUCTURAL STEEL: AT THE CONTRACTOR'S OPTION. HE MAY SUBSTITUTE T/8"OJ SHEAR STUDS FOR THE 3/4"0 STUDS SPECIFIED ON THE PLANS. THIS SUBSTITUTION SHALL BE MADE AT THE RATE OF 3 - T/e"OJ STUDS FOR 4 - Y4"0 STUDS, AND STUD SPACING CHANGES SHALL BE MADE AS NECESSARY TO PROVIDE THE SAME EQUIVALENT NUMBER OF 3/8"0 STUDS ALONG THE BEAM AS SHOWN FOR -/4"O STUDS BASED ON THE RATIO OF 3 - T/8"PJ STUDS FOR 4 - 3/4"¢)STUDS. STUDS OF THE LENGTH SPECIFIED ON THE PLANS MUST BE PROVIDED. THE MAXIMUM SPACING SHALL BE 2'-0". EXCEPT AT THE INTERIOR SUPPORTS OF CONTINUOUS BEAMS WHERE THE COVER PLATE IS IN CONTACT WITH BEARING PLATE, THE CONTRACTOR MAY, AT HIS OPTION, SUBSTITUTE FOR THE COVER PLATES DESIGNATED ON THE PLANS COVER PLATES OF THE EQUIVALENT AREA PROVIDED THESE PLATES ARE AT LEAST 5/6"IN THICKNESS AND DO NOT EXCEED A WIDTH EQUAL TO THE FLANGE WIDTH LESS 2"OR A THICKNESS EQUAL TO 2 TIMES THE FLANGE THICKNESS. THE SIZE OF FILLET WELDS SHALL CONFORM TO THE REQUIREMENTS OF THE CURRENT ANSI/AASHTO/AWS "BRIDGE WELDING CODE". ELECTROSLAG WELDING WILL NOT BE PERMITTED. WITH THE SOLE EXCEPTION OF EDGES AT SURFACES WHICH BEAR ON OTHER SURFACES,ALL SHARP EDGES AND ENDS OF SHAPES AND PLATES SHALL BE SLIGHTLY ROUNDED BY SUITABLE MEANS TO A RADIUS OF APPROXIMATELY ''/16INCH OR EQUIVALENT FLAT SURFACE AT A SUITABLE ANGLE PRIOR TO PAINTING,GALVANIZING, OR METALLIZING. HANDRAILS AND POSTS: METAL STANDARDS AND FACES OF THE CONCRETE END POSTS FOR THE METAL RAIL SHALL BE SET NORMAL TO THE GRADE OF THE CURB, UNLESS OTHERWISE SHOWN ON PLANS. THE METAL RAIL AND TOPS OF CONCRETE POSTS USED WITH THE ALUMINUM RAIL SHALL BE BUILT PARALLEL TO THE GRADE OF THE CURB. METAL HANDRAILS SHALL BE IN ACCORDANCE WITH THE PLANS. RAILS SHALL BE AS MANUFACTURED FOR BRIDGE RAILING. CASTINGS SHALL BE OF A UNIFORM APPEARANCE. FINS AND OTHER DEFORMATIONS RESULTING FROM CASTING OR OTHERWISE SHALL BE REMOVED IN A MANNER SO THAT A UNIFORM COLORING OF THE COMPLETED CASTING SHALL BE OBTAINED. CASTINGS WITH DISCOLORATIONS OR OF NON -UNIFORM COLORING WILL NOT BE ACCEPTED.CERTIFIED MILL REPORTS ARE REQUIRED FOR METAL RAILS AND POSTS. SPECIAL NOTES: GENERALLY, IN CASE OF DISCREPANCY, THIS STANDARD SHEET OF NOTES SHALL GOVERN OVER THE SPECIFICATIONS, BUT THE REMAINDER OF THE PLANS SHALL GOVERN OVER NOTES HEREON, AND SPECIAL PROVISIONS SHALL GOVERN OVER ALL. SEE SPECIFICATIONS ARTICLE 105-4. ENGLISH HLV. b-lb-95 ELM (4) HGW REV. 5-1-03 RWW W) JTE REV. 10-1-11 MAA (4) GM REV. 8-16-99 RWW 0 LES REV. 5-1-06 TLA (4) GM REV. 12-IT MAA (A THC JANUARY,1990 STD. NO. SN