HomeMy WebLinkAboutWQ0037135_Compliance Evaluation Inspection_20190502
May 02, 2019
Dennis Key
Southern Soil Builders Inc
958 Hoots Rd
Roaring River, NC 28669-9148
SUBJECT: Compliance Inspection Report
Southern Soil Builders RLAP
Non-discharge Permit No. WQ0037135
Wilkes County
Dear Permittee:
The North Carolina Division of Water Resources conducted an inspection of the Southern Soil Builders
RLAP on 3/28/2019. This inspection was conducted to verify that the facility is operating in compliance
with the conditions and limitations specified in Non-discharge Permit No. WQ0037135. The findings and
comments noted during this inspection are provided in the enclosed copy of the inspection report
entitled "Compliance Inspection Report".
There were no significant issues or findings noted during the inspection and therefore, a response to this
inspection report is not required.
If you should have any questions, please do not hesitate to contact me at 828-296-4500 or via email
at mikal.willmer@ncdenr.gov.
Sincerely,
Mikal Willmer, Environmental Specialist I
Water Quality Regional Operations Section
Asheville Regional Office
Division of Water Resources, NCDEQ
ATTACHMENTS: Inspection Report
EC: WQS-ARO Server
LF
G:\WR\WQ\Rutherford\Wastewater\Non-discharge\Southern Soil Builder WQ0037135\March 28, 2019 CEI\20190502_WQ0037135_CEI
DocuSign Envelope ID: 4A281A8B-B162-4665-8EE7-57AE3DOEBBF6
Compliance Inspection Report
Permit: WQ0037135
SOC:
County: Wilkes
Region: Winston-Salem
Contact Person: Dennis Key
Directions to Facility:
System Classifications: LA,
Primary ORC:
Secondary ORC(s):
On -Site Representative(s):
Effective: 01/14/19 Expiration: 06/30/19 owner: Southern Soil Builders Inc
Effective: Expiration: Facility: Southern Soil Builders RLAP
397 Riverside Dr
Title: President
Certification:
Forest City NC 28043
Phone: 336-957-8909
Related Permits:
NC0020761 Town of North Wilkesboro - Thurman Street WWTP
NC0006564 Baxter Healthcare Corporation - Baxter Healthcare Corporation
NC0025909 Town of Rutherfordton - Rutherfordton WWTP
NC0021181 City of Belmont - Belmont WWTP
NC0020567 Yadkin Valley Sewer Authority - Yadkin Valley Sewer Authority WWTP
NC0025984 Town of Forest City - Forest City WWTP
Phone:
Inspection Date: 03/28/2019 Entry Time: 01:OOPM Exit Time: 03:OOPM
Primary Inspector: Mikal Willmer DS Phone: 828-296-4686
Secondary Inspector(s):
FDS
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: Land Application of Residual Solids (503)
Facility Status: Compliant ❑ Not Compliant
Question Areas:
Miscellaneous Questions Treatment Land Application Site
Transport
(See attachment summary)
Page 1 of 4
DocuSign Envelope ID: 4A281A8B-B162-4665-8EE7-57AE3DOEBBF6
Permit: WQ0037135 Owner - Facility: Southern Soil Builders Inc
Inspection Date: 03/28/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
Beverly Price and Mikal Willmer with the Asheville Regional Office conducted an inspection of a Class B land application
event on field NMB under Southern Soil Builders (SSB) Permit WQ0037135. David Key, with SSB was present and assisted
in the inspection.
Overall the land application appeared to be carried out in compliance with Permit No. WQ0037135. This was the first liquid
land application event for this field.
The trucks appeared to be well maintained. Each truck had a spill control plan, maintenance log and hauling record.
It is a recommended the verification of vertical separation between the seasonal high water table and the depth of residuals
be added into Souther Soil Builders Operation and Maintenance Plan.
Page 2 of 4
DocuSign Envelope ID: 4A281A8B-B162-4665-8EE7-57AE3DOEBBF6
Permit: WQ0037135 Owner - Facility: Southern Soil Builders Inc
Inspection Date: 03/28/2019 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Type
Yes No NA NE
Distribution and Marketing
❑
Land Application
Treatment
Yes No NA NE
Check all that apply
Aerobic Digestion
Anaerobic Digestion
❑
Alkaline Pasteurization (Class A)
❑
Alkaline Stabilization (Class B)
❑
Compost
❑
Drying Beds
❑
Other
❑
Comment:
Transport Yes No NA NE
Is a copy of the permit in the transport vehicle? ❑ 0 ❑ ❑
Is a copy of the spill control plan in the vehicle? ❑ ❑ ❑
Is the spill control plan satisfactory? ❑ ❑ ❑
Does transport vehicle appear to be maintained? 0 ❑ ❑ ❑
Comment: Permit was on a flash drive, but not accessible for reference at the time of the inspection. Spill
control plan appeared to be satisfactory. Inspectors suggested adding containment and
collection procedures when flushing during spill clean up.
Land Application Site
Yes No NA NE
Is a copy of the permit on -site during application events?
❑
0 ❑ ❑
Is the application site in overall good condition?
❑ ❑ ❑
Is the site free of runoff/ponding?
❑ ❑ ❑
If present, is the application equipment in good operating condition?
❑ ❑ ❑
Are buffers being maintained?
❑ ❑ ❑
Are limiting slopes buffered?
10% for surface application
❑
❑ 0 ❑
18% for subsurface application
❑
❑ ❑
Are there access restrictions and/or signs?
❑ ❑ ❑
Is the application site free of odors or vectors?
❑ ❑ ❑
Have performance requirements for application method been met?
For injection?
❑
❑ ❑
For incorporation?
❑
❑ 0 ❑
Page 3 of 4
DocuSign Envelope ID: 4A281A8B-B162-4665-8EE7-57AE3DOEBBF6
Permit: WQ0037135 Owner - Facility: Southern Soil Builders Inc
Inspection Date: 03/28/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Does permit require monitoring wells?
❑
❑ ❑
Have required MWs been installed?
❑
❑ ❑
Are MWs properly located w/ respect to RB and CB?
❑
❑ ❑
Are MWs properly constructed (including screened interval)?
❑
❑ ❑
Is the surrounding area served by public water?
❑
❑ ❑
If Annual Report indicates overapplication of PAN, are wells nearby that may be impacted?
❑
❑ ❑
Are soil types consistent w/ Soil Scientist report/evaluation?
❑
❑ ❑
Is the water table greater than 173' bls.
❑
❑ ❑
Is application occurring at the time of the inspection?
0
❑ ❑ ❑
Comment: Overall the application site was in good condition, but the field consisted mainly
of weeds. Field
owner intended to plant corn soon. A visual check of the site was conducted; however, cores
were not taken to determine the actual water table depth.
Page 4 of 4