HomeMy WebLinkAbout310305_Compliance Inspection_20180702II (9 Division of Water Resources V
Facility Number j ( - E O Division of Soil and Water Conservation
O Other Agency
for Visit: OfRoutine O
Date of Visit:
Farm Name:
Owner Name:
Mailing Address:
Physical Address:
Referral
O Other 0 Denied Access
Arrival Time: Departure Time: County: Region:
Owner Email:
Phone:
Facility Contact: (� //Title:�
Onsite Representative: r/tc c� ^i / g01+ti fey 4
Certified Operator:
Back-up Operator:
Location of Farm:
Swine
W eau to F i
-Wean to Ft
Feeder to F
Farrow to `
Farrow to 1
Other
Other
Latitude:
Phone:
Integrator:
Certification Number: / 71 fS
Certification Number:
Design Current Design Current
Capacity Pop. Wet Poultry Capacity Pop.
La er
lno S'L7I INon-La er
Design Current
Discharees and Stream Impacts
1. Is any discharge observed from any part of the operation?
Discharge originated at: ❑ Structure ❑ Application Field ❑ Other:
a. Was the conveyance man-made?
b. Did the discharge reach waters of the State? (If yes, notify DWR)
c. What is the estimated volume that reached waters of the State (gallons)?
Longitude:
Design Current
Cattle Capacity Pop.
Dairy Cow
Dairy Calf
Dairy Heifer
Dry Cow
Non -Dairy
Beef Stocker
Beef Feeder
Beef Brood Cow
[—]Yes do ❑ NA ❑ NE
❑ Yes ❑ No ❑ NA ❑ NE
❑ Yes ❑ No ❑ NA ❑ NE
d. Does the discharge bypass the waste management system? (If yes, notify DWR) [:]Yes ❑ No ❑ NA ❑ NE
2. Is there evidence of a past discharge from any part of the operation? ❑ Yes ❑ No ❑ NA ❑ NE
3. Were there any observable adverse impacts or potential adverse impacts to the waters ❑ Yes FfNo ❑ NA ❑ NE
of the State other than from a discharge?
Page I of 3 21412015 Continued
Facility Number: jDate of Inspection: 2
Waste Collection & Treatment
4. Is storage gapacity (structural plus storm storage plus heavy rainfall) less than adequate?
❑ Yes
❑'lap ❑ NA
❑ NE
a. If yes, is waste level into the structural freeboard?
❑ Yes
❑ No ❑ NA
❑ NE
Structure 1 Structure 2 Structure 3 Structure 4
Structure 5
Structure 6
Identifier:
Spillway?:
Designed Freeboard (in):
Observed Freeboard (in): J _
5. Are there any immediate threats to the integrity of any of the structures observed?
❑ Yes
[Nb—'❑ NA
❑ NE
(i.e., large trees, severe erosion, seepage, etc.)
6. Are there structures on -site which are not properly addressed and/or managed through a
❑ Yes
❑'lZo—❑ NA
❑ NE
waste management or closure plan?
If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR
7. Do any of the structures need maintenance or improvement?
[:]Yes
0<0�0 NA
❑ NE
8. Do any of the structures lack adequate markers as required by the permit?
❑ Yes
❑-No —O NA
❑ NE
(not applicable to roofed pits, dry stacks, and/or wet stacks)
9. Does any part of the waste management system other than the waste structures require
❑ Yes
❑ ?Io ❑ NA
❑ NE
maintenance or improvement?
Waste Application
10. Are there any required buffers, setbacks, or compliance alternatives that need
❑ Yes
Q-NU- ❑ NA
❑ NE
maintenance or improvement?
11. Is there evidence of incorrect land application? If yes, check the appropriate box below.
❑ Yes
040-�E] NA
❑ NE
❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals
(Cu, Zn, etc.)
❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge
into Bare Soil
❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application
Outside of Approved Area
12. Crop Type(s):
13. Soil Type(s):
14. Do the receiving crops differ from those designated in the CAWMP?
15. Does the receiving crop and/or land application site need improvement?
16. Did the facility fail to secure and/or operate per the irrigation design or wettable
acres determination?
17. Does the facility lack adequate acreage for land application?
18. Is there a lack of properly operating waste application equipment?
Required Records & Documents
19. Did the facility fail to have the Certificate of Coverage & Permit readily available?
20. Does the facility fail to have all components of the CAWMP readily available? If yes, check
the appropriate box.
❑ WUP ❑Checklists ❑ Design ❑ Maps ❑ Lease Agreements
❑ Yes
0 No
❑ NA
❑ NE
❑ Yes
No
❑ NA
❑ NE
❑ Yes
,[D'No
❑ NA
❑ NE
❑ Yes §Noo
NA ❑ NE
❑ Yes ❑ NA ❑ NE
❑ Yes L21 ❑ NA ❑ NE
❑ Yes �o ❑ NA ❑ NE
❑ Other:
21. Does record keeping need improvement? If yes, check the appropriate box below. [-]Yes ❑�>o ❑ NA ❑ NE
❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Weather Code
❑ Rainfall ❑Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections ludge Survey
22. Did the facility fail to install and maintain a rain gauge? [:]Yes No ❑ NA ❑ NE
23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes ❑ No ❑ NA NE
Page 2 of 3 21412015 Continued
Facili Number: • I Date of inspection: 2
24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes ErNo ❑ NA ❑ NE
25. Is the facility out of compliance with permit conditions related to sludge? If yes, check ❑ Yes No ❑ NA ❑ NE
the appropriate box(es) below.
❑ Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels
❑ Non -compliant sludge levels in any lagoon
List structure(s) and date of first survey indicating non-compliance:
26. Did the facility fail provide documentation of an actively certified operator in charge? ❑ Yes [315o [] NA ❑ NE
27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? ❑ Yes ❑ No l 3 A - ❑ NE
Other Issues
28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document ❑ Yes FZIo ❑ NA ❑ NE
and report mortality rates that were higher than normal?
29. At the time of the inspection did the facility pose an odor or air quality concern? ❑ Yes No ❑ NA ❑ NE
If yes, contact a regional Air Quality representative immediately.
30. Did the facility fail to notify the Regional Office of emergency situations as required by the ❑ Yes No ❑ NA ❑ NE
permit? (i.e., discharge, freeboard problems, over -application)
31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below.
❑ Yes
❑ No
❑ NA
NE
❑ Application Field ❑ Lagoon/Storage Pond ❑ Other:
32. Were any additional problems noted which cause non-compliance of the permit or CAWMP?
❑ Yes
❑'KO'
❑ NA
❑ NE
33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative?
❑ Yes
[21�o
❑ NA
❑ NE
34. Does the facility require a follow-up visit by the same agency?
❑ Yes
12 1
❑ NA
❑ NE
Comments (refer to question ft Explain any YES answers and/or any additional recommendations or any other comments.
Use drawings of facility to better explain situations (use additional a es as necessary).
p (_� ki\t � e �,j -r- C
Reviewer/Inspector Name: 0, t L` 1 " __L- t
Reviewer/Inspector Signature: �1-- -c 1
Page 3 of
Phone: -7(4 -7% %3A
! Date: 2-
21412015