HomeMy WebLinkAboutNCG551725_Compliance Evaluation Inspection_20190430ROY COOPER
Governor
MICHAEL S. REGAN
Serretnry
LINDA CULPEPPER
Director
Bertina AIejandro
2922 Constance Ave
Durham NC 27704-3524
Dear Ms. Alejandro:
NORTH CAROLINA
Environmental Quality
April 30, 2019
Subject: Compliance Evaluation Inspection
2922 Constance Ave SFR
Permit No. NCG551725
(former owner Kenneth Clark)
(former owner All Around, Inc)
Durham County
On April 11, 2019, Joan Schneier from the Raleigh Regional Office visited your single-family
residence (SFR) wastewater treatment system to evaluate compliance with the above permit to
discharge wastewater. The checked boxes below show what conditions were noted at your
facility:
❑ In compliance: You are reminded to regularly maintain the chlorine disinfection
system, have the effluent sampled once a year, and have the septic tank pumped out every
3 to 5 years. Your good record of operation and meeting the permit requirements is
highly commended.
❑ Your home is improperly plumbed: Some of the wastewater discharges are going
directly to the environment without first passing through the treatment system. This must
be corrected immediately. Please submit a schedule to this office within 20 days of
receipt of this letter that states your plan for correcting this deficiency. The work is to be
completed within the next 3 months.
❑ Disinfection: Your system is lacking disinfection, either chlorine tablets or a UV light
system. New rules put into place on August 1, 2007 require all SFR systems to have a
means of disinfection (and dechlorination when chlorine tablets are used to disinfect, if
the system was installed since that date).
® Treatment tablets missing or are wrong kind: You are responsible for always
having chlorine and dechlorination tablets in place. They must be the kind for
wastewater treatment and not for swimming pools.
❑ Dechlorination: Your system was installed after August 1, 2007, so must have a
means of dechlorination located downstream of the chlorinator and its contact chamber.
NUrIh C-imIl Ia Ucparhnrnl of r.IIvironrTit -ill .rl Qmsbty Div!,,ionuf WLiIrr R"ourc c."
� � R,rlciyh Rryiw t.JI Off irc ' 3800Nv mI T Driw 1-46c;h Nur lh C.0 ufkc i 2 609
See Disinfection paragraph above. Please submit a schedule to this office within 20
❑ Pumping the septic tank: The septic tank should be pumped out every 3 to 5 years.
A pumping company can check the status periodically and determine when pumping is
required.
❑ Failure to analyze the effluent: The effluent that is discharged from your system
must be analyzed once each year. See Part I(A) of your permit about his requirement.
Make arrangements for sampling to be carried out within the next 3 months and submit
❑ Locations of treatment units are unknown: Determine this and report to this office
within 30 days of receipt of this letter with a sketch or map. Please locate the discharge
pipe.lease fill out and mail the change of
® Other: if you have not done so already, p g
ownership form that was left during the inspection, to the address on the form.
Both the chlorinator and dechlorinator tubes should always have tablets, but only 2 or 3
per tube should be present. They swell up in wet conditions and tend to jam.
Our file notes show that the septic tank was replaced on August 15, 2017.
If you have questions or comments about this inspection or the requirements to take corrective
action, please contact Joan Schneier or me at 919-791-4200. Licensed plumbers should be used
to make plumbing changes within your home. Contractors for installing disinfection or other
equipment may be found in the Yellow Pages under Environmental Consultants.
*Sinccy,
Rick Bolich, L.G.
Water Quality Regional Assistant Supervisor
Raleigh Regional Office
Attachments:
Inspection Report
Tablet Suppliers
cc: (minus attachments)
RRO'SWP Files
NPDES Permitting Unit Files — Charles Weaver
United Stares Env ronmentat Protectirn Agency Form Approved.
EPA Washington D c. 2D46-
OMB No 2040-0057
Water Compliance Inspection Report Approval expires 8-31-96
Section A. National Data System Coding (i.e., PCS)
Transaction Code NPDES yrlmolday Inspection Type Inspector Fac Type
1 (ti ( 2 Is 1 3 NCG551725 11 12 19/04/11 17 18 u 19 L G I 20I
IJ U J L
8
211- 1
Inspection Work Days Facility Self Monitoring Evaluation Rating B1 OA Reserved
72 LJJ 73174 751 I I I I I I I80
67 701LJ 71 itJ
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES permit Number)
01 05PM 1910411
17106.+19
2922 Constance Ave
Exit T melDate
Permit Expiration Date
2922 Constance Ave
Durham NC 27704
01 20PM 1910411
1807i31
Name(s) of Onsite Representabve(s)lTides(syPhone and Fax Number(s)
Other Facility Data
!11
Name, Address of Responsible Official/Title- Phone and Fax Number
Kenneth Clark,2922 Constance Ave Durham NC 2770411919.325.6200, Contacted
N_f
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit 0 Operations & INa:ntenance 0 Effluent/Receiving Waters
Section D: Summary of FindinglComments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Dale
Joan Schnerer RRO GWR+
r30601?
Signature of Management O A Reviewer Agency/Office/Phone and Fax Numbers Dal
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete
Page#
NPDES yrlmolday Inspection Type (Cont.)
31 NCG551725 I11 12 19104711 17 18I lsI
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
This was an unannounced inspection due to lack of contact information, and no one was home.A
change of ownership form, deed and dropoff letter were left in the front door.
Per email query, the septic tank was replaced on 08/15/2017 by McFarland Septic in conjunction with
other work on the system.
The assumed underground sand filter area was clean and kept mowed.
The chlorinator and dechlohnator were empty with greyish -black sludge on the sleeves.
The riprapped outfall ditch had some grayish sludge but also some clear puddles.The stream below
the outfall seemed to be in good shape.
It is quite possible that the sand filter is approaching the end of its useful life.
Non -compliant due to need to change owners and use tablets.
Page#
Permlic NCG551725 Owner - Facli ty: 2922 Constance Ave
Inspection Date: 04/11/2019 Inspection Type: Compl ance Evaluation,
Permit
Yes No NA NE
(If the present permit expires in 6 months or less). Has the pennittee submitted a new
❑
0
❑
❑
application?
Is the facility as described in the permit?
❑
❑
❑
# Are there any special conditions for the permit?
❑
❑
0
❑
Is access to the plant site restricted to the general public?
❑
❑
M
❑
Is the inspector granted access to all areas for inspection?
M
❑
❑
❑
Comment: A change of ownership form deed and dro off letter were left in the front door.
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ 0 ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Septic Tank
Yes No NA NE
(If pumps are used) Is an audible and visual alarm operational?
❑
❑
M
❑
Is septic tank pumped on a schedule?
❑
❑
❑
Are pumps or syphons operating properly?
❑
❑
M
❑
Are high and low water alarms operating properly?
❑
❑
M
❑
Comment: Per email queCy. the septic tank was replaced on 08/15/2017 by
McFarland Septic in
coniunction with other work on the system
Sand Filters ILow rate)
(If pumps are used) Is an audible and visible alarm Present and operational?
Is the distribution box level and watertight?
Is sand filter free of ponding?
Is the sand filter effluent re -circulated at a valid ratio?
# Is the sand filter surface free of algae or excessive vegetation?
# Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1)
Comment: The assumed underground sand filter area was clean and kept mowed.
Disinfection -Tablet
Are tablet chlorinators operational?
Are the tablets the proper size and type?
Yes No NA NE
❑ ❑ M ❑
❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ■ ❑
■ ❑ ❑ ❑
❑ ❑ ■ ❑
Yes No NA NE
M ❑ ❑ ❑
❑ M ❑ ❑
Page# 3
Permit NCG551725
owner - Facility: 2922 Constance Ave
Inspection Date: 0411112019
Inspection Type: Compliance Evaluation
Disinfection -Tablet
Yes No NA NE
Number of tubes in use?
2
Is the level of chlorine residual acceptable?
❑
❑
❑
0
Is the contact chamber free of growth, or sludge buildup?
❑
❑
❑
M
Is there chlorine residual prior to de -chlorination?
❑
❑
0
❑
Comment: The chlorinator and dechlorinator were empty with greyish -black sludge on the sleeves.
De -chlorination Yes No NA NE
Type of system ? Tablet
Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ M ❑
Is storage appropriate for cylinders? ❑ ❑ M ❑
# Is de -chlorination substance stored away from chlorine containers? ❑ ❑ ❑ M
Comment:
Are the tablets the proper size and type?
Are tablet de -chlorinators operational?
Number of tubes in use?
2
❑ M ❑ ❑
■ ❑ ❑ ❑
Comment: The chlorinator and dechlorinator were empty with greyish -black sludge on the sleeves.
_Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained? M ❑ ❑ ❑
Are the receiving water free of foam other than trace amounts and other debris? M ❑ ❑ ❑
If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ M ❑
Comment: The ripra ped outfall ditch had some grayish sludge but also some clear puddles.The
stream below the outfall seemed to be in good shape._
Page# 4