Loading...
HomeMy WebLinkAboutNCG550451_Compliance Evaluation Inspection_20190328ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Director Mr. Richard Marcotullio 162 Brookdale Dr Advance, NC 27006 yd�l r, LV � NORTH cAROLINA Environmental Quality March 28, 2019 SUBJECT: Compliance Evaluation Inspection Certificate of Coverage NCG550451 162 Brookdale Dr Davie County Dear Mr. Marcotullio, RECEIVE.0IDENRIDWR APR 2 9 2019 Water Resources i''®rmit�ing section On March 25, 2019 Kelli Park and Gary Hudson, of this office, met with you to perform a Compliance Evaluation Inspection of the wastewater treatment system located at the above address. The State requires the Division of Water Resources to inspect these types of systems at least once every five years. The only area of concern from the inspection is that the effluent water has not been tested by a laboratory. Water samples from the effluent are required to be analyzed at least once a year by a certified laboratory. These records are required to be maintained and should be shared with NCDEQ upon request. The inspectors, however, were made aware that you have not seen effluent flow from the pipe hence why it has not been sampled. Laboratory contact information and a data sheet were provided to you in an event where discharge is seen flowing from the pipe. Please keep this letter with your records for the system along with copies of invoices from the Division for the annual permit fee, the Certificate of Coverage, records of septic tank pumping, maintenance and repair records, etc. If you have any questions regarding the inspection or this report, please contact Kelli Park or me at (336) 776-9800_or by email at kelli.parkO-ncdenr.gov or Ion. snider(c-ncdenr.gov. Sincerely, DoeuSgnad by: Lott 'C a5tu�v Assistant Regional Supervisor Water Quality Regional Operations Division of Water Resources Attachments: EPA Water Compliance Inspection Report cc: Central Files W_$RO NPDES ;Unit ` United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 �N 2 I5 1 3 I NCG550451 I11 12 19/03/25 17 18 ICI 19 I c I 20LJ 21IIIIII I I I I I I I I I I I I I I I I I I i i I I I I I I I I I I I I I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 67 70 LJI 71 J72 LrJ 73 I 74 751 I I I I I I80 Section B: Facility Data. Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 11:00AM 19/03/25 13/08/01 162 Brookdale Drive 162 Brookdale Dr Exit Time/Date Permit Expiration Date Advance NC 27006 11:45AM 19/03/25 18/07/31 Names) of Onsite Representative(s)/Tities(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number • Contacted Richard J Marcotullio,162 Brookdale Dr Advance NC 27006//336-998-4207/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Gary Hudson Division of Water Quality//336-776-9694i Kell! A Park WSRO WQ//336-776-9689/ Signature of Management Q A Revi SW-dW.Agency/Office/Phone and Fax Numbers Date'C iL-D-'Saxe, 1 3/28/2019 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day . Inspection Type (Cont.) 31 NCG550451 I11 12 19/03l25 18 17 C Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) 1) Chlorine tubes were located and had tablets in them. They are located to the left of the house hidden by bushes. Tablets are checked each month and added when needed. 2) Norweco chlorine tablets are used. 3) The system was last pumped November 2018 and it is reported that the system is pumped each year. , 4) The pipe was located to the back right of the house. Effluent flows onto a step aerator and then into a creek. The pipe and steps were clean. 4) Typically there is no effluent flowing out of the pipe. Due to this, the effluent has not been tested. 5) Information was provided by the inspector- lab contact information and the most recent technical bulletin. ' Page# k Permit: NGG550451 Owner - Facility: 162 Brookdale Drive Inspection Date: 03/25/2019 Inspection Type: Compliance Evaluation Permit (If the present permit expires in 6 months or'less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Yes No NA NE ❑ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ Comment: There was effluent flowing out of the discharge pipe at the time of inpsection, but it was most likely due to rain water that had filled up in the chlorine contact tank. The effluent was clear. Page# 3