Loading...
HomeMy WebLinkAboutWQ0037984_Variance Request_20190417ROY COOPER Governor MICHAEL S. REGAN . Secretary_ LINDA CULPEPPER Director ' NORTH CARO.LINA Erivironmental Quality April 17,, 2019 Ed, Parvin, Town Manager Town of Carolina Beach 1121 North: Lake Park Boulevard Carolina Beach, NC 28428 Subject: Variance Request Approval Town. of Carolina Beach Phase C— Utility_ Improvements.(WQ0037984). E-SRP-W47-0066 Dear Mr..Parvin: :. The Division of Water Resources (Division). has reviewed_ the submitted variance request received on January.2, 2019 for the subject project: The Division will grant the variance request for the. usage of interference boxes and the.installation of.gravity line below the minimum required slope in accordance with the provisions for alternative design under 15A NCAC: ,. 02T.0105(n): . 1. Pursuant to the variance request received January 2, 2019 from Engineering Services; R.A. behalf of the Town of Carolina Beach; a: variance is granted for the construction and operation of approximately 2,038 linear, feet of 8-inch•gravity sewer between manholes MH-174, MH-173A, MW-173, MH-172, MH-171A and MH-171 and between. manholes MH-168A,•MH-168, MH-167A, MH=16713; and MH-167 at slopes of 0.24% - 0.26% as indicated on the provided plans, specifications, and supporting documents, and.subject to the following requirements: a. The sections of gravity sewer as described above shall be designated as "high-;, priority sewer" in accordance.with' 15A NCAC 02T.0402. . b. High -,priority sewers shall be inspected by,the permittee or its representative at least once every six -months in accordance with the permittee's individual system -wide collection system per (WQCS00076). . 2, Pursuant to the variance request received J,6nuary:21 2019 from Engineering Services,. P.A.; on behalf of the.Town of Carolina Beach; a variance is granted for the construction and operation of approximately 10 linear feet of.10=inch ductile iron and approximately 55 linear feet of 8-inch ductile iron gravity sewer, set_ inside a steel carrier pipe within a total of 13 interferenceeboxes. ' Gravity sewer lines suspended through interference boxes to resolve intersections with . storm drains shall be constructed of ductile iron pipe and sleeved in a steel carrier pipe North Carolina Department of Environmental Quality I Division of Water Resources D'Eel�, 512 North Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617 . N TH CAROLMA. 919.707.9000 for.a minimum distance.of 27feet to either side of.the interference box, in accordance with the provided plans and supplementary documentation. These lines shall be designated as high -priority: sewers, subject to the conditions as outlined above .in Item #1(a=b). Regardless of.the variance approval, in the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Perm'ittee shall take. immediate corrective action, including those as may be, required by this Division, such as the construction of additional or replacement facilities. All other. elements of this project shall be constructed in accordance with all applicable rules and statues including, 15A NCAC 2T; the Division of Water Resources.' (Division) Gravity Sewer Minimum Design Criteria adopted; February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains. adopted June 1, 2000 as applicable. Approval of the, variance request does.not constitute approval of the permit. If you have any questions; please, contact Christyn Fertenbaugh, P.E. at 919-707-3625:or via email at'christyn.fbrtenbaukhC@h6dehr.gov.* Sincerely, for. Linda Culpepper Director, Division of Water Resources by Deborah Gore, PERCS Supervisor Division of Water Resources, NCDEQ cc: Brian G. Cox, P.E.; Engineering Services, P.A. (becox@bellsouth.net) Wilmington Regional Office, Water Quality Section Regional. Operations Water.Quality Central Files - WQCS00076 PERCS Files (electronic copy)