Loading...
HomeMy WebLinkAbout310217_Compliance Inspection_20180621Faeility Number ©- /® O Division of Soil and Water Conservation O Other Agency (Type of Visit: QJ Compliance Inspection U Operation Review() Structure Evaluation U Technical Assistance I Reason for Visit: 7Routine O Complalnt O Follow-up O Referral O Emergency O Other O Denied Access Date of Visit: 2 //, Arrival Tlme: (l O Departure Time: ® County: Farm Name: K d D Bev Ng- Owner Email: Owner Name: Mailing Address: Physical Address: Phone: Facility Contact: 4rM14- / ' l d6wl Title: Onsite Representative: Certified Operator: Back-up Operator: Location of Farm: Swine Wean to F Wean to F Feederto Farrow to Farrow to Farrow to Other Other Latitude: Phone: Integrator: Region: Certification Number: & 7'F3 Certification Number: Design Current Design Current Capacity Pop. Wet Poultry Capacity Pop. [Layer QI JNon-Layer Design Current Dry Poultry CBpaeity Pon. Layers Non -Layers Pullets Turkeys Turkey Points Other Discharges and Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? b. Did the discharge reach waters of the State? (If yes, notify DWR) c. What is the estimated volume that reached waters of the State (gallons)? d. Does the discharge bypass the waste management system? (If yes, notify DWR) 2. Is there evidence of a past discharge from any part of the operation? 3. Were there any observable adverse impacts or potential adverse impacts to the waters of the State other than from a discharge? Longitude: Design Current Cattle Capacity Pop. Dairy Cow Dairy Calf Dairy Heifer Dry Cow Non -Dairy Beef Stocker Beef Feeder Beef Brood Cow ❑ Yes "No ❑ NA ❑ NE ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes [—]No [—]Yes JUNo [—]Yes ;a No ❑ NA ❑ NE ❑NA ❑NE ❑NA ❑NE ❑NA ❑NE ❑NA ❑NE Page I of 21412015 Continued Facili Number: Date of Inspection: y/ {Waste Collection & Treatment 4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? ❑ Yes KNo ❑ NA ❑ NE a. If yes, is waste level into the structural freeboard? ❑ Yes ❑ No ❑ NA ❑ NE Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: Spillway?: Designed Freeboard (in): Observed Freeboard (in): 5. Are there any immediate threats to the integrity of any of the structures observed? ❑ Yes UNo ❑ NA ❑ NE (i.e., large trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a ❑ Yes ,rNo ❑ NA ❑ NE waste management or closure plan? If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR 7. Do any of the structures need maintenance or improvement? ❑ Yes �No ❑ NA ❑ NE 8. Do any of the structures lack adequate markers as required by the permit? ❑ Yes JU No ❑ NA ❑ NE (not applicable to roofed pits, dry stacks, and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ Yes allo ❑ NA ❑ NE maintenance or improvement? Waste Application 10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ Yes No ❑ NA ❑ NE maintenance or improvement? 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes No ❑ NA ❑ NE ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.) ❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area 12. Crop Type(s): 13. Soil Type(s): 14. Do the receiving crops differ from those designated in the CAWMP? ❑ Yes N2;%Io ❑ NA ❑ NE 15. Does.the receiving crop and/or land application site need improvement? ❑ Yes No ❑ NA ❑ NE 16. Did the facility (fail to secure and/or operate per the irrigation design or wettable ❑ Yes f No ❑ NA ❑ NE acres determination? 17. Does the facility lack adequate acreage for land application? ❑ Yes X No ❑ NA ❑ NE 18. Is there a lack of properly operating waste application equipment? ❑ Yes No ❑ NA ❑ NE Required Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? ❑ Yes No ❑ NA ❑ NE 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check ❑ Yes No ❑ NA ❑ NE the appropriate box. ❑WUP ❑Checklists ❑Design ❑Maps ❑LeaseAgreements ❑Other: 21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes IN No ❑ NA ❑ NE ❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Weather Code ❑ Rainfall ❑ Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey 22. Did the facility fail to install and maintain a rain gauge? ❑ Yes O No ❑ NA ❑ NE 23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes J�f No ❑ NA ❑ NE Page 2 of 3 V4/2015 Condnued Facility Number: 3 jDate of Inspection: 124. DiBthe facility fail to calibrate waste application equipment as required by the permits ❑ Yes 0 No ❑ NA ❑ NE 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check ❑ Yes EkrNo ❑ NA ❑ NE the appropriate box(es) below. ❑ Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance• 26. Did the facility fail provide documentation of an actively certified operator in charge? 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drams exist at the facility? If yes, check the appropriate box below. ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other. 32. Were any additional problems noted which cause non-compliance of the permit or CAWIvT? 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? 34. Does the facility require a follow-up visit by the same agency? ❑ Yes MNo ❑ NA ❑ NE ❑ Yes ❑ No ® NA ❑ NE ❑ Yes Pi No ❑ NA ❑ NE ❑ Yes Z No ❑ NA ❑ NE ❑ Yes (M No ❑ NA ❑ NE ❑ Yes 0 No ❑ NA ❑ NE ❑ Yes No ❑ Yes] No ❑ Yes J]2-No ❑NA ❑NE ❑ NA ❑ NE ❑ NA ❑ NE Comments (refer to question #): Explain any YES answers and/or any additional recommendations or any other comments. Use drawings of facility to better explain ppsituations (use additional pages as necessary). " `o efr1a,; I - /meilArr 0 rJerr,5ow Reviewer/Inspector Name: _, Reviewer/Inspector Signature: Page 3 of 3 Phone: 9�() - %9�" 2306- Date: 2i/ 21412015