Loading...
HomeMy WebLinkAbout20170938 Ver 2_More Information Received_20190424Staff Review Does this application have all the attachments needed to accept it into the review process? r Yes r No ID#* Version* 2 20170938 Is this project a public transportation project?* r Yes r No Reviewer List:* Paul Wojoski:EADS\pavtojoski Select Reviewing Office:* Central Office - (919) 707-9000 Submittal Type:* Application Attachments Does this project require a request for payment to be sent?* r Yes r No Project Submittal Form Please note: fields marked with a red asterisk below are required. You will not be able to submit the form until all mandatory questions are answered. Project Type: r New Project r Pre -Application Submittal r More Information Response r Other Agency Comments r For the Record Only (Courtesy Copy) New Project - Please check the new project type if you are trying to submit a new project that needs an official approval decision. Pre -Application Submittal - Please check the pre -application submittal if you just want feedback on your submittal and do not have the expectation that your submittal will be considered a complete application requiring a formal decision. More Information Response - Please check this type if you are responding to a request for information from staff and you have and ID# and version for this response. Other Agency Comments - Please check this if you are submitting comments on an existing project. Is this supplemental information that needs to be sent to the Corps?* r Yes r No Project Contact Information Name: Richard Harmon Woo is submitting the inforrration? Email Address: richard.harmon@woodplc.com Project Information Existing ID #: Existing Version: 20170938 2 20170001 (no dashes) Project Name: Carolina Connector Intermodal Rail Terminal and Line of Road Improvements Is this a public transportation project? r Yes r No Is the project located within a NC DCM Area of Environmental Concern (AEC)? r Yes r No r Unknown County (ies) Edgecombe Nash Please upload all files that need to be submited. Click the upload button or drag and drop files here to attach docurrent 00 DWR RAI Response Letter CSX IP 04.17.19.pdf 212.94KB Attach ment_01—CSX USACE_ 6.22MB RAI_Response_03.22.19 v2.pdf Attachment_02_CSX USACE_ form_ 4345_p3signe... 5.11 MB Attach ment_03_Appendix F_Riparian Buffer 6.34M6 Authorization. pdf Attach ment_04_EandS_Plan_Sheets.pdf 2.87MB Attachment_05_Rocky Mt Stormwater plans.pdf 24.26MB Attach ment_06_PlanviewDrawings sheets1-4.pdf 35.7MB Attach ment_07_Figure 14a. rev Mitigation Work 835.49KB Plan.pdf Attach ment_08_Figure 17. rev PRMP.pdf 891.85KB Attach ment_09_Figure 18 Proposed Planting 1.08M6 Plan.pdf Attach ment_10_Figure 14b. rev Mitigation Work 855.19KB Plan.pdf q_1 Revised Pgs CCX Permit Drawings 04.09.19.pdf 3.06MB REDUC Environmental Report Figures.pdf 3.35MB CCX Environmental Report_01-17-19.pdf 1.19MB Only pdf or krm files are accepted. Describe the attachments: Wood has uploaded the CCX Environmental Report (01-17-19), the wetland/stream impact drawings (q_1 revised pgs CCX Permit Drawings 04.09.19), and the Environmental Report Figures. In addition, Response to March 28, 2019 DWR letter (00 DWR RAI Response letter CSX IP 04.17.19) and attachments 01 through 10. V By checking the box and signing box below, I certify that: • I have given true, accurate, and complete information on this form; • I agree that submission of this form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act") • I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act'); • I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND • I intend to electronically sign and submit the online form." Signature: Submittal Date: 04/24/19 Is filled in autorratically. 1 Mr. Paul Wojoski 17 April 2019 401 & Buffer Permitting Branch NC Division of Water Resources Department of Environmental Quality 512 North Salisbury Street (Archdale Building), Suite 942-F Raleigh, North Carolina 27604 RE: Response to Request for Additional Information DWR # 17-0938 v2X Carolina Connector Intermodal Rail Terminal and Line of Road Improvements - Individual Permit Application Dear Mr. Wojoski: CSX Transportation, Inc. (CSX) and the co-applicant, the North Carolina Department of Transportation (NCDOT), in consultation with Wood Environment & Infrastructure Solutions, Inc. (Wood), submitted a standard permit application to the Raleigh Regulatory Field Office of the U.S. Army Corps of Engineers (USACE) for issuance of Section 404 Individual Permit (IP) (USACE Action ID SAW -2016-02338) for the Carolina Connector Intermodal Rail Terminal (CCX) and Line of Road Improvements in Rocky Mount, Edgecombe and Nash Counties. The application and supporting documents were also provided to the North Carolina Department of Environmental Quality (NCDEQ), Division of Water Resources (Division/DWR), as requesting an Individual Water Quality Certification from the DWR for the project. On January 29, 2019, the Division received the application dated January 17, 2019, requesting a modification to Individual Water Quality Certification and Buffer Authorization DWR # 17-0938 v2X for the subject project. On February 1, 2019, the USACE issued a Public Notice for the project that expired on March 3, 2019 and was received by the Division on February 1, 2019. DWR subsequently determined that the application was incomplete and could not be processed until specific information was provided to the Division. The information/respective responses are presented below with requested materials enclosed for the Division to review and consider the application to be complete. General/Administrative Information Item Number 1 The application and supporting documents you uploaded to the Divisions online Laserfishe repository is one file, 4,588 pages in length. Many pages contained rendering errors making them unreadable. The large size of the file and lack of electronic indexing causes difficultly in loading and reviewing. Please re-upload the application and supporting documents, breaking up the file as appropriate to smaller parts/sections that are legible. Response The application and supporting documents will be provided (uploaded to Division Laserfishe repository after receiving authorization/access from DWR) to the Division in a digital format separated by section to facilitate review. 2 Item Number 2 Please copy the Division on any response to USACE request for more information sent March 14, 2019, including any response to address comments received during the USACE public notice period. Response A copy of the response (dated 22 March 2019) to the USACE Request for Additional Information is included as Attachment 1. Item Number 3 The USACE individual permit application page 3 of 3 was not signed by CSX Transportation, Inc., or the authorized agent. Please provide a signature page. Response The requested signature page, as signed by CSX Transportation, Inc., is included as Attachment 2. Item Number 4 The Division of Water Resources Riparian Buffer Authorization Form was not signed (page 6 of 6). Please provide a signature page. Response The requested signature page for the DWR Riparian Buffer Authorization Form is included as Attachment 3. Item Number 5 Please provide a close-up, detailed, plan view of the stream impacts that consist of culvert installation. Is any rip-rap proposed with culvert installation? Does the impact table account for temporary impacts associated with the installation? Please list all temporary impacts separately from permanent impacts. Response Close-up, detailed, plan-view drawings of the stream impacts associated with culvert installation are provided as Attachment 4. Sheets ES-402 & ES-403 show details for the rock-lined channel and outlet protection. All outfalls will have Rock Channel Protection per City of Rocky Mount Standard Drawing 3.22, with the Riprap sized in accordance with the NCDEQ Erosion and Sediment Control Planning and Design Manual. Where indicated, ditches will be lined with stone in accordance with City of Rocky Mount Standard Drawing 3.10, with rock sized in accordance with the manual. All impacts within the shown Limits of Disturbance are permanent. There are no temporary impacts proposed on the Site. Item Number 6 On page ES-2, executive summary of the Environmental Report, bottom paragraph, 277, 708 SF of buffer credit is cited as the quantity needed to offset the proposed impacts. 3 According to the application documents 666,162 SF of buffer mitigation is needed. Please clarify and correct if necessary. Response Page ES-2 of the Environmental Report (ER) has been revised to reflect the correct riparian buffer impacts and mitigation credits as follows: 277,708 sq. ft. of riparian impacts for Zone 1 and 2 requiring 662,112 sq. ft. of Tar-Pamlico Riparian Buffer Compensatory Mitigation Credits. The revised ER is included with the new application package which will be uploaded to the Division’s online Laserfishe repository as requested in Item #1. Item Number 7 Provide a final SEPA approval issued from the State Clearing House. Please be advised that while work on an environmental document is in progress, no Department of Environmental Quality (DEQ) agency shall undertake any action which might limit the choice among alternatives or otherwise prejudice the ultimate decision on the issue. [15A NCAC 0lC .0107]. Response The Council on Environmental Quality released a memorandum to compare/contrast the National Environmental Policy Act (NEPA) with the North Carolina State Environmental Policy Act (SEPA). In the memorandum, it states that, “[w]here a North Carolina agency is required to prepare or comment on an environmental document under Federal Law, the agency does not have to prepare an additional environmental document under SEPA if the NEPA document or comment meets the requirements of SEPA”. Through the Section 404 IP process, the USACE is preparing a Corps EA for this project, which completes the NEPA requirement. Hence, the SEPA requirement is met. Stormwater Item Number 8 Has the stormwater management plan been submitted to the City of Rocky Mount for approval? If so, please provide a copy of the stormwater design drawings. Response The Stormwater Management Plan for the CCX and Line of Road Improvements project has been submitted to the City of Rocky Mount for approval. A copy of the stormwater design drawings is included as Attachment 5. Item Number 9 Please provide information on the stormwater management for the undetained areas. How much impervious surface is proposed in each undetained area? Where will the stormwater flow and will vegetative receiving areas be provided? Response With the proposed BMPs, 99% of the proposed impervious area will be treated for water quality, and with the exception of a portion of the entrance drive will also be treated for 4 water quantity. Below is a summary of what is included in each undetained area, and in addition see Attachment 6: • Undetained 101 - includes a portion of the impervious site access drive and north lead track but is primarily undeveloped area. The only undetained impervious area is along the access drive (1.12 acres) as shown in the attached exhibit. There is not stormwater detention for the roadway, but it is treated by a grass swale for water quality, and this was accounted for within the nutrient calculations. While this area does not have stormwater detention, the increased flows from the roadway were accounted for in the overall release rate for Area 101. • Undetained 102 - entirely undeveloped grass, field, and woods. • Undetained 103 - primarily undeveloped grass, field, and woods; includes a portion of the gravel drive for cemetery access (1.06 acres) • Undetained 104 - primarily undeveloped grass, field, and woods; includes a portion of the gravel drive for cemetery access (0.88 acres) and also a small portion of the south lead track near the connection to the mainline. Mitigation – General Comments The Division has reviewed the Swift Creek Permittee Responsible Mitigation Plan (PRMP) and has the following general comments regarding the mitigation plan: Item Number 10 Throughout the document, please change Department of Environmental Quality (DEQ) to Division of Water Resources (DWR). Response This requested change will be made throughout the revised PRMP. Item Number 11 The conservation easement is for both the DWR & USACE but is noted throughout as the "USACE easement." There is a template that has been approved by the DWR & USACE for easements. Please use this template for the PRMP. Response The model conservation easement template provided in Appendix B was obtained from the USACE Wilmington District website. The PRMP will be revised to reflect the conservation easement as “NCDWR/USACE easement”. Mitigation – Stream and Wetland Mitigation Plans The Division has reviewed the Swift Creek Permittee Responsible Mitigation Plan (PRMP) and has the following comments regarding the stream and wetland mitigation plans [15A NCAC 02H .0502(h)]: 5 Item Number 12 Instead of labeling and referring to features as "Relatively Permanent Waters (RPW)s," label as "stream" or "ditch." Response This requested change will be made throughout the revised PRMP. Item Number 13 Figure 10 "Aquatic Resources Map" shows UT-Kl and UT-K2 as ditches, however, figure 14a shows these features as stream preservation. These features should not be listed as stream preservation. Response On Figure 14a UT-K1/I-1 and UT-K-2/I-2 were shown as preservation for graphical purposes only. These aquatic features were not included in the mitigation work plan summary table included on Figure 14a. Figure 14a has been revised (Attachment 7) to show the features as ditches rather than preserved streams and is included in the revised PRMP. Item Number 14 The Division recommends the ratio for reach B-1 be 10:1. Response The Applicants and their Agents request further clarification/justification for the proposed stream preservation ratio for reach B-1 being decreased from 5:1 to 10:1. The Division previously approved the use of a stream preservation ratio of 5:1 with the 401 approval letter dated December 21, 2017. The Applicants and their Agents contend that the uplands/buffers within the PRMP project and the eventual bank site provide significant protection above and beyond the typical requirements. In addition, the PRM site seeks to restore, enhance, and preserve headwater stream and wetland systems that flow directly to Swift Creek, known to provide habitat for the Tar River Spinymussel and Yellow Lance, both on the List of Endangered and Threatened Wildlife. Item Number 15 Section 5.1.1- The mitigation credits listed in the first bullet appear to be for the entire site as proposed in the previous authorization request, not the current credits as shown in Table 2, please revise. Response The first bullet in Section 5.1.1 will be revised in the PRMP to reflect the proposed mitigation credit requirement for the project. 6 Item Number 16 Section 5.8.1.2 - Wetland Hydrology- The Division recommends the wetland hydrology performance criteria for the Roanoke soils on this site be at least 10%. While the current October 2016 Mitigation Update lists Roanoke soils as 9-12%, the Inter-agency Review Team (IRT) has recently revised some of the ranges and the Roanoke soil series now shows a range of 10-12%. In addition, the success criteria for years 1 and 2 remains 10%, any changes are up to the discretion of the USACE Project Manager and/or the IRT. Response The Division previously approved the stated hydrology performance criteria under Section 5.8.1.2 with 401 approval letter dated December 21, 2017. Under Section 5.8.1.2 of the PRMP, the performance criteria were stated as follows: “Wetland hydrology will be considered established if well data from the wetland enhancement areas indicate that groundwater is within 12 inches of the soil surface for 7% target saturation period for monitoring years one and two, and 9-12% for monitoring years three through seven of the annual growing seasons during normal weather conditions.” The Applicants and their Agents concur with the increase in the revised range for Roanoke Soils (10%-12%), however, contend that the performance criteria be adjusted to 10% for monitoring years three through seven and maintain the 7% target saturation for monitoring years one and two is sufficient. Given the existing conditions and historical framing practices utilized at the proposed PRM site, associated with the ditching and draining of existing wetlands and historically hydric areas, the groundwater table has most likely been lowered well below naturally occurring wetland systems. It is anticipated that once the restoration activities are complete, it will take some time for the groundwater hydrology to naturalize with the proposed modifications. The 7% target saturation for monitoring years one and two, and 10% for monitoring years three through seven will provide adequate time for the proposed wetland enhancement areas to naturalize. If the 10% requirement is not being met by the end of monitoring year three, then adaptive management in consultation with the Division and the USACE may be required. Section 5.8.1.2 of the PRMP will be revised to reflect the requested change from 9% to 10% target saturation. Item Number 17 Figure 8 shows the USGS flow paths for the proposed project. Figure 14a shows the proposed Mitigation Work Plan. It appears that the supporting hydrology for Tributary K will remove much of the supporting hydrology that would contribute to Tributary B1. The Division is concerned that there will not be enough flow to maintain even an intermittent channel throughout the monitoring period. Please realize that to receive stream mitigation credit, Tributary B1 must show the appropriate channel features and flow to earn credit. The Division recommends installing a stream gauge mid-reach on B1 to verify throughout the monitoring period. Response The Applicants and their Agent concur that the proposed mitigation work plan will direct surface and groundwater flow from Wetland No. 2 shown on Figure 10 in Appendix A of 7 the PRMP. However, the natural hydrology and flow of land was previously diverted through historic farming practices by the construction of stream/ditch UT -1, also shown on Figure 10. The proposed mitigation work plan, through the construction of Tributary K, proposes to restore the historic flow path of surface waters to the site and does not consider the diversion of flow to be a significant portion of Tributary B-1’s hydrology. Additionally, Tributary B-1 originates off-site and the majority of this stream system flows along the northwestern property boundary as shown on Figure 10. The Applicants and their Agents concur that Tributary B-1 must show the appropriate stream features following the monitoring period to earn mitigation credit and agree to install a stream gauge along Tributary B-1 to verify hydrology in accordance with the proposed monitoring period and performance requirements. Figure 17 is provided as Attachment 8. Appendix A in the PRMP will be revised to reflect this requested modification. Item Number 18 Figure 17 - The Division recommends adding monitoring gauges, one near station 50+50 (design sheet A12) and one near station 59+00 (design sheet A13). Response The Applicants and their Agents agree to add stream gauges near Station 50+50 and 59+00. Figure 17 is provided as Attachment 8. Appendix A in the PRMP will be revised to reflect this requested modification. Item Number 19 Design sheets - the design shows a single thread channel (A0l and A02} extending well beyond the Intermittent/Perennial point as seen on Figure 10. The headwater restoration should begin near the bottom of A02 near station 06+00. In addition, the sheets show a single thread channel. The Division recommends grading a floodplain valley (very shallow with minimal grading and nearly flat side slopes) with wood placed in the lowest part of the valley to provide opportunity for bed diversity formation. The Division believes headwater restoration is the preferred method for reaches K and Upper A-1, and the development of a single thread would probably not be likely until near the confluence of A-1 and K. Moreover, a headwater stream method is preferable for B-2 until the road. Please note comment #15 as it affects reach B-2 as well. Response The Applicants and their Agents concur regarding proposed construction methods for the headwater stream portions of the proposed PRMP. The single thread channel illustrated on the 30% Design Drawings within the designated headwater restoration areas shown on Figure 14a (Attachment 7) in Appendix A was illustrated for graphical purposes only. The Applicants and their Agents concur that the headwater restoration is appropriate for the upper reaches of Tributary A-1 as illustrated on Figure 14a (Attachment 7) in Appendix A; however, does not agree that Tributary K and the portion of B-2 beyond the confluence with Tributary A-1 should be considered for headwater restoration. It is anticipated that the hydrology provided by Wetland No. 2 will support a single thread channel as currently exhibited by UT-1 shown on Figure 10 in Appendix A. Additionally, 8 it is anticipated that the hydrology for Tributary B-2 downstream of the confluence with Tributary A-1 to the existing road crossing is sufficient to support a single thread channel. The estimated watershed for this section of stream is 0.2 sq. miles. Item Number 20 Stream mitigation credit for headwater stream restoration is calculated using valley length not from a meandering single thread channel. Response The Applicants and their Agents concur that the mitigation credit for headwater stream restoration be based on the on the valley length and not from the meandering single thread channel. The proposed restoration reach links provided in Table 2 of the PRMP for Tributary A-1 (Headwater) and Tributary B-2 (Headwater) were based on the estimated valley length for each proposed headwater restoration reaches (see Attachment 7 Figure 14a Table 2). Item Number 21 The Division recommends a stream gauge be placed mid reach for reaches B-2, K, and upper A-1. Response The Applicants and their Agents concur with this request to add stream gauges along the proposed restoration reaches B-2, K, and Upper A-1. Figure 17 is provided as Attachment 8. Appendix A in the PRMP will be revised to reflect this requested modification. Item Number 22 Please describe what allowances/plans are being considered for the confluence of a stream restoration channel coming from the eventual bank site near stations 49+00/49+50. Response It is anticipated that the construction schedule for all proposed stream restoration reaches within the PRM site and the eventual bank site will occur concurrently and be constructed by the same construction contractor. In the event that the construction of the bank portion of the stream restoration reaches is delayed and following the completion of the PRM stream restoration reaches, all effort s will be taken to avoid adversely disturbing the previously-constructed restoration reaches within the PRM site. The Applicants and their Agents may elect to construct a portion of the restoration reach tied to the eventual bank site at the confluence near station 49+00/49+50 to allow for this portion of the stream reach to be completely stabilized. 9 Item Number 23 In the future, the Division would like the design sheets to show the plan view and the longitudinal profile on the same sheet. Also, the Division prefers to see the longitudinal profile at a scale that planned bedform diversity can be discernible. Response The Applicants and their Agents anticipate the development of construction design plans for all proposed stream restoration reaches following the approval of the proposed PRMP. The development of the construction design plans will include a longitudinal profile at a scale that the proposed bedform diversity can be discerned. If requested, the Applicant and its Agent shall provide copies of the construction plans to the Division once they are complete. Item Number 24 The Division recommends the wetland preservation ratio be 7.5:1. Response The Applicants and their Agents request further clarification/justification for the proposed wetland preservation ratio decrease from 5:1 to 7.5:1. The Division previously approved the use of wetland preservation ratio of 5:1 with the 401 approval letter dated December 21, 2017. The Applicants and their Agents contend that the provided uplands/buffers within the PRMP project and the eventual bank site provide significant protection above and beyond the typical requirements. In addition, the PRM site seeks to restore, enhance, and preserve headwater stream and wetland systems that flow directly to Swift Creek, known to provide habitat for the Tar River Spinymussel and Yellow Lance, both on the List of Endangered and Threatened Wildlife. Mitigation – Buffer Mitigation Plan The Division has reviewed the Swift Creek PRMP and has the following comments regarding the buffer mitigation plan [15A NCAC 02B .0295]: Item Number 25 There is reference to "nutrient offsets" in the PRMP. Please note, that nutrient offsets cannot be generated on this PRMP. This permittee-responsible mitigation (PRM) is to meet 401/404 and buffer impacts associated with the CSX project noted in the plan. Remove all reference to nutrient offsets. Response The Applicants and their Agents concur that the PRMP cannot generate nutrient offsets. The PRMP will be revised to remove all references to Tar-Pamlico nutrient offsets. Item Number 26 Table 6 - It appears UT-K1 is supposed to be I-1 and K-2 is I-2? See Page 18. Please verify/correct. 10 Response Table 6 in the PRMP references the delineated aquatic features within the PRMP site and the nomenclature corresponds to the Buffer viability letters provided by the Division on July 25, 2017, and November 2, 2017. Due to the complexity of the proposed mitigation work plan, the site feature names were adjusted during the development of the plan to avoid overlap since several stream features were being filled, combined, or created. This resulted in UT-K1 and UT-K2 being renamed to UT-I1 and UT-I2 in this mitigation work plan. Item Number 27 Please provide a complete and detailed planting plan. Response The Proposed Planting Plan has been added to Appendix A and illustrates where the proposed planting zones are to be located as described in Section 5.4.4 of the PRMP. The revised plan is included as Attachment 9. Item Number 28 The main goal of buffer mitigation sites is for planted hardwood trees to reach maturity and establish a protected forested community in perpetuity. However, some of the proposed activities as noted below contradict that goal and are not in compliance with buffer mitigation sites regulated under 15A NCAC 02B .0295 (n). Specifically: a. Prescribed burning is prohibited by DW R within the conservation easement area and would affect the hardwood species required for planting. b. Planting long leaf pines does not comply with the performance standards outlined in 15A NCAC 028 .0295 (n)(2) for buffer mitigation sites. c. "Active Management" of riparian areas as noted in the document appears to include management that would not be supported in the buffer mitigation areas such as burning, pruning, thinning, trails, horses, et cetera. (See Section 5.10 Long-Term Management). It is important to note that the conservation easement will also restrict activities within it and would prohibit management of trees, hydrology, et cetera outside of the monitoring years. Examples of this active management language in the PRMP that is problematic/prohibited include: i. "Buffer zones within the USACE area may be burned to allow for mosaic of plant communities." (page 53) ii. "... upland areas may be more actively managed relying on disturbance regimes such as burning, disking, mechanical & chemical treatments ... " (page 53) iii. " a network of single tract trails will be installed... " (page 53) iv. " educational signage maybe placed in various locations along the trails." (page 53) Where are the referenced trails located? Are they inside or outside of the easement? Please provide more details of the 11 trails. Will trees have to be removed for their construction? Will the trails be impervious? d. The placement of a "blue trail" is mentioned in the plan. Comments from the Division on this blue trail were provided in the previous version of this plan submitted in 2017. What is the "blue trail"? Please provide a figure showing a preliminary outline of the trail. e. Vernal pools, unless planted with hardwood trees, would not meet performance standards for buffer mitigation credits. Therefore, vernal pool must be excluded from the square footage of buffer mitigation. This plan needs to be revised where it conflicts with, or is non-compliant with, the expectations of buffer mitigation sites outlined in 15A NCAC 02B .0295. Response The PRMP will be revised to requirements set forth under 15A NCAC 02B .0295. The proposed Longleaf Pine Savanna Establishment and associated long-term active management strategies, which included prescribed burning and the establishment of fire breaks, will be removed from the proposed PRM and eventual bank site. The PRMP will be revised to remove Sections: 5.4.4.5 Wet Pine/Mesic Pine Flatwood Establishment, 5.4.4.8 Prescribed Burning, and 5.4.4.9 Fire Breaks. Section 5.4.4.1 Planting Plan will be revised to show that Zone 1 will consist of Mixed Hardwood Forest establishment in-lieu of Longleaf Pine Forest Establishment. Figure 18 (Attachment 9) has been added and illustrates the proposed planting zones. The proposed Tar-Pamlico riparian buffer zones are anticipated to be planted with Zone 2: Bottom Land Hardwood Forest and Zone 3: Cypress-Gum Swamp. Zone 1: Mixed Hardwood will be planted in the upland zones outside of the Tar-Pamlico buffers. Future active management activities conducted by the Tar River Land Conservancy (TRLC) may consist of the establishment of single-track impervious trails and educational signage. The TRLC’s vision for the property is to promote and provide educational opportunities for the public by providing access to the wide variety of native habitats within the proposed PRM and eventual bank site. All active management activities will occur outside the proposed Tar-Pamlico Buffers. Active management activities would include the potential addition of an established blue trail along Swift Creek. “A blue trail is a river/stream adopted by communities that are dedicated to improving family friendly recreation such as fishing, boating, hiking, and wildlife-watching, and to protecting rivers and surrounding lands” (www.Bluetrailsguide.org). It is anticipated that a canoe launch may be established, outside the proposed PRM site along the banks of Swift Creek, to promote public awareness, access, and conservation of this valuable aquatic resource. Section 5.4.4.7 has been revised to state that vernal pools will be established with native vegetation. It is anticipated that a combination of Zone 2 and Zone 3 trees will be incorporated into the vernal pools where extended inundation is expected to occur resulting from bankfull and greater storm events. Since the vernal pools are expected to be established with hardwood vegetation and will be monitored accordingly, the Applicants and their Agents contend that the vernal pools should be included in the Tar- Pamlico riparian buffer zone. 12 Item Number 29 If a headwater stream restoration is conducted, the buffer mitigation area is measured perpendicular to the length of the valley being restored as noted in 15A NCAC 02B .0295 (o)(2). The figures provided show a sinuous channel. Additionally, to use these areas for buffer mitigation, they must be compliant with all of 15A NCAC 02B .0295 (o)(2). Please describe how these streams will meet this rule to generate buff er mitigation. Note, that preservation areas/forested areas adjacent to coastal headwater stream restoration sites do not meet this rule. Updated figures and tables are expected with this change. Response Table 2 and Figure 14b (see Attachment 10) have been revised to account for the buffer mitigation area being measured perpendicular to the length of the valley where buffer mitigation is to occur adjacent to proposed headwater restoration areas. Only planted buffers will be utilized to generate buffer mitigation credit adjacent to headwater restoration areas. The actual buffer credit generated adjacent to headwater stream restoration areas will be dependent upon the successful establishment of the headwater stream, confirmed by an as-built. Item Number 30 Headwater streams are not credited until an as-built confirms their construction. Please account for any buffer mitigation areas being altered based on headwater stream restoration. Response The Applicants and their Agents concur that the mitigation credits generated from headwater stream restoration will confirmed by the Division and the USACE with an as- built survey establishing that the performance criteria have been met. Item Number 31 Section 5.8 needs to include the DWR in addition to USACE on any alternative mitigation proposed. Response Section 5.8 in the PRMP will be revised to include the DWR, as requested. Item Number 32 Section 5.8.4 - Some of the performance standards for generating buffer mitigation credit in this section differ from 15A NCAC 02B .0295. Some of the performance standards are more stringent. Address any language that does not at least comply with 15A NCAC 02B .0295 (n)(2). Additionally, only desirable hardwood species may count towards the stem/acre requirements for buffer mitigation areas. Overall, the species listed on page 37 seem acceptable. Response The performance standards in Section 5.8.4 will be revised to comply with the standards found in 15A NCAC 02B .0295 (n)(2). 13 Item Number 33 Monitoring should be done no earlier than Late Summer/Fall (late August is the earliest). Response Section 5.9.4 of the revised PRMP will be revised to state that “Vegetation monitoring will occur between August 15 and leaf drop”. Item Number 34 Is the Carolina Vegetation Survey (CVS) protocol being used to monitor the site? Response Section 5.9.4 of the revised PRMP will be revised to be consistent with the Level 1 (Planted stem inventory plots) and Level 2 (Total wood stem inventory plots) outlined in the CVS-EEP protocols. Item Number 35 Monitoring reports should be submitted to the Division in addition to the USACE since there is buffer mitigation proposed. Response The Applicants and their Agents will provide the Division with a copy of the Monitoring Report, as requested. The PRMP will be revised to reflect this request. Please note that the revised PRMP will be submitted following concurrence from the Division to our responses included herein. Thank you in advance for your assistance with this project. If you have any questions or need additional information, please contact Mr. Harmon at (919) 381-1366 or email richard.harmon@woodplc.com. Sincerely, Allen Conger Richard Harmon Principal Scientist Senior Associate Biologist Branch Manager - Columbia, SC Attachments Cc: Samantha Dailey (USACE) Matthew L. Adkins (CSX) Tony C. Coggins (NCDOT 1 Ms.Samantha Dailey March 22, 2019 Raleigh Regulatory Field Office U.S. Army Corps of Engineers 3331 Heritage Trade Drive, Suite 105 Wake Forest,North Carolina 27587 RE:Response to Request for Additional Information USACE Action ID: SAW-2016-02338 Carolina Connector Intermodal Rail Terminal -Individual Permit Application Rocky Mount, Edgecombe County, North Carolina Dear Ms. Dailey: CSX Transportation, Inc. (CSX),in consultation with Wood Environment & Infrastructure Solutions, Inc.(Wood E&IS)submitted a standard permit application to the Raleigh Regulatory Field Office of the U.S.Army Corps of Engineers (USACE)for issuance of Section 404 Individual Permit (IP)for the Carolina Connector Intermodal Rail Terminal (CCX) in Rocky Mount, Edgecombe County.Subsequent to the review of the application and supporting documents as provided in the Public Notice (advertised on February 1, 2019),responses were given by three federal and state agencies, a Native American representative, and one private landowner. The responding agencies and individuals included: United States Fish and Wildlife Service (USFWS),North Carolina Wildlife Resources Commission (NCWRC),National Oceanic and Atmospheric Administration - National Marine Fisheries Service (NMFS),Cherokee Nation -Tribal Historic Preservation Office, and Mr.Marion Barnes.Wood received a copy of the set of responses on March 14, 2019,via email correspondence from you to Mr. Matthew Adkins, CSX.Responses to three comments are presented below; i.e., USACE, NCWRC, and Mr. Barnes.The NMFS, in correspondence to the USACE dated February 5, 2019, stated that the proposed project would not occur within the vicinity of essential fish habitat.The USFWS, in correspondence to the USACE dated March 1, 2019, stated that the agency had no objection to the activity as described in the permit application. USACE Comment In the March 14, 2019 USACE correspondence, the agency stated the following: “Permit drawings appear to be disjointed which make it difficult to assess the project a whole. Please provide an overall permit drawing that shows the entire site, impacts,and aquatic resource labels in accordance with the jurisdictional determination.” Response An overall permit drawing with 5 corresponding enlarged drawings on 11 X 17 depicting the entire site is attached for the use of the USACE. 2 NCWRC Comment In March 1, 2019 correspondence from the NCWRC to the USACE, the NCWRC provided the following comments and recommendations for the CCX mitigation site within the Swift Creek watershed (Swift Creek Perrnittee Responsible Mitigation Plan): “Staff have conducted onsite visits to the 593-acre site and believe the site in its entirety would provide numerous habitat opportunities for terrestrial, avian, and aquatic wildlife resources once restoration and enhancement activities are complete. This area in the Tar River system is defined as a critical priority area needing protection by the NC Division of Water Resources, The NC Natural Heritage Program, and the Tar River Land Conservancy. Swift Creek is designated an anadromous fish spawning area (AFSA) by the NCWRC. In addition to serving as spawning habitat for anadromous fish, numerous priority species such as yellow lance (Eliptio lanceolata), Roanoke slabshell (Eliptio roanokenisy, and Carolina madtom (Noturus furiosus) can be found in the area. Preservation of the riparian area to Swift Creek protects water quality and in tum important aquatic habitat. Terrestrial wildlife will also benefit from the contiguous upland and wetland areas. We believe the function of the area, however, would be reduced if only the proposed 196.5-acre mitigation area is restored. To better serve wildlife habitats and water quality, the entire site should be included in a restoration plan, rather than just a part. It is understood that the current impacts from the CCX Terminal and rail improvements do not require the entire property to meet its mitigation needs. However, a large portion of the site's value is lost with the reduced area. We recommend continued restoration efforts on the property. It is also unclear if the access opportunities for research and sampling to Swift Creek, once included in the previous proposal, still remain. Access points in this area are uncommon and the ability to access Swift Creek for sampling and research would greatly increase opportunity to improve management of several non-game aquatic species.” Response CSXT and Palustrine Group are committed to the restoration and protection of the entire Swift Creek parcel. The revised CCX plans have made it necessary to accomplish this in two phases: Phase 1 is for the CCX Permittee Responsible Mitigation Plan and Phase 2 will be a mitigation bank sponsored by Palustrine Group, which proposes to enhance and restore the remainder of the property. A prospectus for the remainder of the property will be submitted by Palustrine Group to the Interagency Review Team in the near future. Mr. Marion Barnes Comment In February 5, 2019 correspondence from Mr. Marion Barnes, a private landowner, to the USACE, Mr. Barnes stated the following: “I received postcard yesterday about Corps receiving application from CSX about permits for CCX Terminal in Rocky Mount.I am a business owner @3201,N. Wesleyan Blvd (Hwy 301) in Rocky Mount & my land backs up to the railroad on the 3 Nash County side of the tracks.Directly behind my property on the Edgecombe side are the two grave yards mentioned in the public notice statement put out by Corps.I want to know if this is plan is going to impact, or involve my property? also,I would like to know where the milepost mentioned are located?I went on CSX website & cannot find a map that specifically shows location of these mile post.The numbers of the milepost in the notice are A115.4 to A112.2 to A110.6.” Response A map showing the limits of the CCX project, the railroad mile marker numbers, corresponding longitude and latitude of the mile makers, and parcels adjacent to the CCX project was provided to Mr. Barnes as an attachment via email on February 18, 2019. A copy of the map forwarded to Mr. Barnes is attached to this response. Thank you in advance for your assistance with this project. If you have questions or need additional information, please contact Dicky Harmon at 919-381-1366 or by email richard.harmon@woodplc.com or Allen Conger at 803-798-1200 or by email allen.conger@woodplc.com. Sincerely, Richard Harmon Principal Scientist Senior Associate Biologist Project Director Enclosures o ON 'A1NnOO HSVN 8 z19IN00H0az o £0£L-0SL-£Os:Xej zQ< DPwLj so`3�u�3� S1N3W3/�02idWl o 00ZL-86L-£08:181 �sw��,a ��oNo�w� �NFNI` N GNOO�S (INV sew 0 26Z eugoleO yynog'elgwnlo'J ��ow�� �ww��a�oz o ¢ 0 o Z£Lalyng'peobwaoejE)OZL o=>��w� _�"�����m CD � WNInHAi �If/�ci �f/Q0Wzi�1Nl 3 x o ,oul'einpnjlse4ul N? o 00004 o—=M m m y x i 3 Uaa�—tt <V=lww L,m3 OV / m +g luawualnu3 poom Z§zz>—dZ ANNVNI oaa>om mp vix< um>zjZNNoJxmwt)mw <oSEA IMd2R411W�d =>� Q o 3oo «tOO N IVOI1dldOSIa A llva nla :103road 8 o � w �r =o a w o <� _< <" m 0 QOW / I sE3sa ' 'd / / g / Lo neo a, p F � oaW��-------------- \\\\ e / \ E_n _i� W =z �~ I I \ I v =y // 3rz .r?�A °p'u +�'sip� I_ H1Vd IL3HIW I/ mag Ali I / RY W¢ E PPTH — — KJ _m Ii 'o \ \ E 8 Co nm / 4�2? om- \ / �8 �q �;a \ / Z, tit/ d0 N>\ 1 — aali bra nwww� 4 / o �� H 31 / maI N 0tl X'J8 NNIWI0l 1__— _ II �6 81 I $I I I I I I I I � I � \ I I I TOTAL WETLAND IMPACT: 6.86 AC TOTAL STREAM IMPACT' 4,041.9 LF O 0 IMPACT NUMBER OPEN WATER NAME TOTAL IMPACT (AC) SHEET NUMOER OW -1 OPEN WATER 1 0.22 2 SUMMARY OF WETLAND IMPACTS SUM MARY OF STREAM IMPACTS w 5-6 = 1402.07 2 LU o HCL w = ci IMPACT NUMBER WETLAND NAME TOTAL IMPACT (AC) SHEET NUMBER IMPACT NUMBER WETLAN❑ NAME TOTAL IMPACT (AC) SHEET NUMBER W-1 4 -LT 40.01 1 w-10 I 0.5 2 Z LL1 C p o W-2 P -LT 0.18 1 W-11 � 0.06 4 W W p ❑ a= n W-3 5 -LT 0.04 1 W-12 M -LT 0.01 4 F -LL U7 c o _ W-4 T -LT 0.07 1 W-13 W- LT 0.14 4 } a W-5 4 0.30 1 w-14 Y C0.01 4 Q Q _ o �a w—s a 0.13 z w-15 cc <0.0 p) x C] w o u N E Y v Q N a i S v 4 E u o E E E N Z. E O N P E Y_ u J rn SUMMARY OF OPEN WATER IMPACTS a r `a u L d V C] C N V I S m 0 0 o Y N H— 0 a31 Wi Q } a W-7 P 0.35 2 w-16 BB 0.02 5 W -S E 3.01 2 W-17 ❑❑ 0.1 5 SHEET NUMOER OW -1 OPEN WATER 1 0.22 2 5-6 SE 1402.07 2 1 5 S-8 SG 321.94 4 W-9 H 1.95 2 W-18 N 40.01 4 IMPACT NUMBER STREAM NAME TOTAL IMPACT (LF} SHEET NUMBER 5-1 57 325.06 1 S-2 58 34.2 1 5-3 SC 157.54 1 5-4 SD 109 2 z 5-5 SD 405.48 2 5-7 SEE 720.61 2 S-9 512 48.26 4 s-10 $1 1ze.4s 4 S-11 513 168.28 4 SHEET NUMOER OW -1 OPEN WATER 1 0.22 2 5-6 SE 1402.07 2 SHEET NUMOER OW -1 OPEN WATER 1 0.22 2 START OF CSX cz PROJECTAREA o 0 g+ c U IMPACT W-1 WETLAND O -LT: X0.01 ACRES PROPOSE ACCESS ROAD PROPOSED SOUTH LEAD TRACK -------------- ----- " --- 09 0a1H WETLAND 4M 56 'I -LT IMPACT W-2 STREAM WETLAN❑ P -LT: 0.18 ACRES IMPACT S-2 S9 STREAM STREAM S8: 5B WETLAND 34.2 LF R r_ _. - L 1 CROSS SECTION ` G -G' y■■ 4 CROSS PROPOSED SIDING ` r SECTION F -F' TIE-IN TO TANNER RD F XISTING RAILROAD 1I M PACT INSTRUMENT I W-3 QR TO BE WETLAND CLOSED i S-LT:0.04 j ACRES — IMPACT W-5 WETLAND 0: 0.30 ACRES f W WETLAND U WETLAND 5 -LT STREAM S7 IMPACT S-1 STREAM S7: N IMPACT W-4 325.06 LF WETLAND T -LT: 0.07 ACRES I W''ETLAND r IMPACT S-3 �� 0 PF j WETLAND STREAM SC: T -LT LLI LLI POSED RAIL r C`.FNTFRLINEI LJ J j 1 157.54 LF CROSS STREAM SECTION E PROPOSED ` EXISTING CEMETERY y SIDING CSX r -E' 5C ``_ CENTERLINE PROJECT 1 A ` (TO REMAIN) +� AREA EXISTING � + RAILROAD ~ IMPACT W-4 325.06 LF WETLAND T -LT: 0.07 ACRES I W''ETLAND r IMPACT S-3 �� 0 PF j WETLAND STREAM SC: T -LT LLI LLI POSED RAIL r C`.FNTFRLINEI LJ J j 1 157.54 LF CROSS STREAM SECTION E EXISTING CEMETERY r -E' 5C ``_ (TO REMAIN) +� cc 1 WETLAND PROPOSED A INTERMODAL Z+ � STREAM YARD � 1 — Z of STREAM LL vol ? +S L COLLEGE RD �J J TO BE CLOSED Q C,O�'� PROPOSED LL STORMWATER POND (TYP.) 4 44 CSX PROJECT AREA X\ Uf� 0f ❑l LIMITS OF DISTURBANCE WI LL f I rl I ( TYP. ) .. +i7ilr�r r .... 71r�1 rn�iriu ri�i ryr'�41Arirrpyrl �irrroi„ 4ppir B C = +� ii _ LLm � � n c in 0 0 0 0 a v o= IL ii E CL n S4 2 p C J W d d d 0 ta rr x ❑ w 0 w CL q Lu I I Ullm w w LL_ Q Z a CV U-) 4- w II 0 O J= 9 uLo r L0 L1W Q = U Q CCO7 0 Q a i n 0 0 A A 1 A ~ A A A A A A A A A A 1 A A k EXISTING EXISTING GROSSING RAILROADf W�S��� A A A CSX PROJECT f A czA A _ H - $ AREA --_ H f PROPOSED V$ 307 TELECOMMUNICATION A A A TOWER SITE A ` H:..: f (BY OTHERS) ` PROP SED RAIL ryo f CENTERLINE ---- _ - -- (TYP.) ff STREAM S23 PROPOSED "._ WETLAND SIDING ` - NN CENTERLINE ` W E) IS ING f W CEMETERY (TO REMAIN)' o :...,:l�D - � � IMPACT W-10 LLI GOLLEG� ( � S WETLAND I: 0.5 ACRES r LJ I IMPACT S-4 WETLAND H COLLEGE RU TO _,% STREAM SD: BE CLOSED 109 LF IMPACTS -5 r STREAM 5D: 405.28 LF W z- IMPACT W-7 WETLAND P: 0.35 ACRES "- STREAM CROSS SECTION D -D' IMPACT W-8 WETLAND E: 3.01 ACRES PROPOSED STORM WATER H POND (TYP.) h rn� WETLAND $ E g STREAA.? SE -- _ ------ WETLAND H�..... . SECTION C -C' IMPACT S-6 STREAM SE: 1402.07 LF LIMITS OF STREAM DISTURBANCE 55 x 11' �� SE CONTAINER STREAM LIZ PARKING SEC (TYP-) STREAM SED Hl A C UNE SEE }�� IMPACT W-6 �J WETLAND B: LL a STREAM 0.13 ACRES PROPOSED S1 ❑ � STORM WATER 77 IMPACT S-7 POND (TYP.) C Q STREAM SEE: WETLAND a d 720.61 LF E LLl o STREAM � SD CL E? va S11 A o CSX PROJECT a AREA LIMITS OF DISTURBANCE IMPACT W-7 WETLAND P: 0.35 ACRES "- STREAM CROSS SECTION D -D' IMPACT W-8 WETLAND E: 3.01 ACRES PROPOSED STORM WATER H POND (TYP.) h rn� WETLAND $ E g STREAA.? SE -- _ ------ WETLAND H�..... . SECTION C -C' IMPACT S-6 STREAM SE: 1402.07 LF LIMITS OF STREAM DISTURBANCE 55 x 11' �� SE CONTAINER STREAM LIZ PARKING SEC (TYP-) STREAM SED Hl A C UNE SEE STREAM CROSS SECTION B -B' 1 PROPOSED CULVERT WETL~ (TYP) WATER � EN WATER 1 IMPACT OW- :.'.: e 1 OPEN WATER 1: - - 0.22 ACRE S IMPACT S-8 STREAM SG- 321.94 LF STREAM el (ALSO ON z FS SHEET 314) H H H� IMPACT W-9 WETLAND H: LL a STREAM 1.95 ACRES QS S1 ❑ � (p1} 77 IMPACT S-7 � C Q STREAM SEE: a d 720.61 LF 0 LLl o STREAM CL E? va S11 A o g a h� LIMITS OF DISTURBANCE STREAM CROSS SECTION B -B' 1 PROPOSED CULVERT WETL~ (TYP) WATER � EN WATER 1 IMPACT OW- :.'.: e 1 OPEN WATER 1: - - 0.22 ACRE S IMPACT S-8 STREAM SG- 321.94 LF STREAM el (ALSO ON z FS SHEET 314) H H H� -e C LL a LL QS C � (p1} 77 f6 N � C Q c x a d 0 LLl CL E? o a o g a o La n n D- ' 0- a 2 o — ❑ 0- d a` d m -e D U o (p1} a a E c x a d J LLl CL E? J a it CD a o _ � ' 0- ❑ .� w x co .� w d w I I MATCHUNE SEE SHEET 2 - - - PROPOSED J -- CULVERT - JYP) STREAM f so 4_ POND IMPACT S-8 �1 1 2 STREAM SG: 321.94 LF {ALSO ON SHEET 214) WETLAND STREAM - sGa I� I I I f Patio W { 4 CSX PROJECT PONS AREA _ 1 _ J J _ J J J J J J l J � �0-'F d Qfp� l wl mI � J � ' 0 UI � J J I � J I � J t J I I I 1 I � I �l �l V W V J Z U Q �G V U) vi € Q d7 °i E C = U O D y L o m ❑ L) LU CL N U �(will w w LL a � p N QJ= O Q Q U Q d7 = U D] d � CQ Q a 0 a b n 0 0 IMPACT S-9 STREAM S12:48.26 LF IMPACTS -10 Dg STREAM SI: 128.46 LF ` IMPACT W-11 WETLAND J: 0.06 ACRES ? PROPOSED 46 SIDING STREAM CENTERLINE � 512 a c - ° IMPACT W-18 L� _.........: a WETLAND N: WETLAND a�'�x X0.01 ACRES W PROPOSED WA I J •°a r STDRMWATER STREAM S� � POND (TYP.) (BEECH BRANCH) STREAM c� SG WETLAND 4 � K �. �� WETLAND � LQD C CROSS �` b WETLAND SECTION IMPACT S-8 �`� `� L A -A' STREAM SG: 321.94 LF ALSO ONr� WETLAND SHEET 2!3 � M POND WETLAND 4 $ � M—LT—LT LIMITS C1E p1STURF3ABANCE I PROPOSED ACCESS ROAD STREAM S13 WETLAND r I IMPACT W-12 - WETLAND M -LT: 0.01 ACRES (BEECH BRANCH) ti -- 6o�fl Rp CROSS SECTION H -H' CSX PROJECT WETLAND AREA CROSS ry SECTION I -r - IMPACT S-11 STREAM S13: 168.28 LF IMPACT W-13 WETLAND W -LT: 0.14 ACRES WETLANC EXISTING W -L] EDGECOMBE GENCC COAL SIRING TRACK /I \ / 1 fr ofI w+ O+ m W Qf f�+ Q� 01 WETLAND Y WETLAND i Ln D \ W \ \ LLI LLI PROPOSED SIDING r n TIE-IN TO �f j EXISTING RAILROAD EXISTING RAILROAD WETLAND STREAM AA 4 LLIr BEGIN LINE OF ROADS IMPROVEMENTS Jo INSET 4.1 SCALE 1" = 200' gg EXISTING Sl 3A eM CEMETERY (Td REMAIN) 11 -IL IMPACT W-14 WETLAND Y: FA X0.01 ACRES Q +` I \ I � w w LL a a CV w II O J= q ¢ r Lo Ln U Q = U Q CD 0 Q a R 0 0 L0 F- 0 s U f STREAM Jf C Z�' S14 Qf I = y l,Cf��f (►J , � U � f QII — _ — _ US 301 NRTH = Q h 11EL0 PROPOSED LIME m OF ROADS ] IMPROVEMENTS m m _ � v z EXISTING 5 Q ❑ o Q b __ RAILROAD a a Q7�1 A 1 N FFFHrill � � ` ���� 1 ��A BOURNE ST _�� � z � � � �;$ WETLAND IMPACT W-16 - B9 WETLAND B6: .2 ❑ 1 1 a 0.02 ACRES y q) ci � 1 a o c, w a s CSX PROJECT �1 _ AREA 1=�1 1 END OF CSX WETLAN❑ PROJECT AREA r owl of `- cc ` J 1 1 0�1 IMPACT W-15 o WETLAND CC: 1 '� o m 1 1 ` X0.01 ACRES CROSS ¢ o — — — 1 SECTION J -J' j cc' _ c LIMITS OF = a c - DISTURBANCE a r 1 4 IMPACT W-17 LU �J WETLAND DD: ly w 0.1 ACRES 1� 0 w w LL 1 CD Z p h! � 4— w II O J= O <r Lo V)w b] 0;\ ¢ a] _�•■ • elH �� a Mile Mile 110.6va Longitude Latitude 110.6 -77.74213918 36.06089874 112.2 -77.75392330 36.03958043 115.4 -77.77467188 35.99663515 kdi.o W Saltleel Ave _ Battlabao a M1e p0 SVI 4R1t t y� dome rt B 0 v Iv Pa �Mile -112.2k a° P*\s Soll Lake °t Belment"W Sele l \\ 3 � RR _L "'mill Rn E m N'oEpnR� Seven0ntl9n Pa D a -- Legend Rn Parcel 386210352278 (Bames) e'y O Mlle 115.4 Q LOR Work Extents r o ese nod Rd CCX Project Boundary a � Adjacent Parcels nneR=• y D 4 05 1 2 °oraee Miles U.S. ARMY CORPS OF ENGINEERS APPLICATION FOR DEPARTMENT OF THE ARMY PERMIT OMB APPROVAL 003 EXPIRES: 28 FEBRUARY20 20133 33 CFR 325. The proponent agency is CECW-CO-R. Public reporting for this collection of information is estimated to average 11 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of the collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters, Executive Services and Communications Directorate, Information Management Division and to the Office of Management and Budget, Paperwork Reduction Project (0710-0003). Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. Please DO NOT RETURN your form to either of those addresses. Completed applications must be submitted to the District Engineer having jurisdiction over the location of the proposed activity. PRIVACY ACT STATEMENT Authorities: Rivers and Harbors Act, Section 10, 33 USC 403; Clean Water Act, Section 404, 33 USC 1344; Marine Protection, Research, and Sanctuaries Act, Section 103, 33 USC 1413; Regulatory Programs of the Corps of Engineers; Final Rule 33 CFR 320-332. Principal Purpose: Information provided on this form will be used in evaluating the application for a permit. Routine Uses: This information may be shared with the Department of Justice and other federal, state, and local government agencies, and the public and may be made available as part of a public notice as required by Federal law. Submission of requested information is voluntary, however, if information is not provided the permit application cannot be evaluated nor can a permit be issued. One set of original drawings or good reproducible copies which show the location and character of the proposed activity must be attached to this application (see sample drawings and/or instructions) and be submitted to the District Engineer having jurisdiction over the location of the proposed activity. An application that is not completed in full will be returned. (ITEMS 1 THRU 4 TO BE FILLED BY THE CORPS) 1. APPLICATION NO. 2. FIELD OFFICE CODE 3. DATE RECEIVED 4. DATE APPLICATION COMPLETE (ITEMS BELOW TO BE FILLED BY APPLICANT) 5. APPLICANT'S NAME 8. AUTHORIZED AGENT'S NAME AND TITLE (agent is not required) First - Matthew Middle - L. Last - Adkins First - Richard Middle - Last - Harmon Company - CSX Transportation, Inc. Company - Wood Environment & Infrastructure Solutions, Inc E-mail Address - Matt—Adkins@csx.com E-mail Address - richard.harmon@woodplc.com 6. APPLICANT'S ADDRESS: 9. AGENT'S ADDRESS: Address- 351 Thornton Street, Suite 125 Address- 4021 Stirrup Creek Drive, Suite 100 City - Lithia Springs State - GA Zip- 3012 Country -US City - Durham State - NC Zip - 2770 Country -US 7. APPLICANT'S PHONE NOs. w/AREA CODE 10. AGENTS PHONE NOs. WAREA CODE a. Residence b. Business c. Fax a. Residence b. Business c. Fax 770-819-2849 919-381-1366 919-381-9901 STATEMENT OF AUTHORIZATION 11. 1 hereby authorize, Richard Harmon to in my h f as y agent in the processing of this application and to furnish, upon request, supplemental information in support of this permit appl' ati 2 SI NATU E OF APPLICANT DTE NAME, LOCATION, AND DESCRIPTION OF PROJECT OR ACTIVITY 12. PROJECT NAME OR TITLE (see instructions) Carolina Connector Intermodal Rail Terminal and Line of Road Improvements, Edgecombe and Nash Counties, NC 13. NAME OF WATERBODY, IF KNOWN (if applicable) 14. PROJECT STREET ADDRESS (if applicable) Beech Branch Address Old Battleboro Road 15. LOCATION OF PROJECT Latitude: -N 36.01458 Longitude: ^W -77.76345 City - Battleboro State- NC Zip - 16. OTHER LOCATION DESCRIPTIONS, IF KNOWN (see instructions) State Tax Parcel ID 386371624400 Municipality Edgecombe County, NC Section - N/A Township - N/A Range - N/A ENG FORM 4345, OCT 2012 PREVIOUS EDITIONS ARE OBSOLETE. Page 1 of 3 17. DIRECTIONS TO THE SITE CCX Intermodal Site: From Raleigh, take US 64 to Rocky Mount. Take US 301 North to College Road. Turn right on College Road. Site is on both sides of College Road Line of Road Improvements: Along the existing mainline from Milepost A110.6 in Rocky Mount north to Milepost Al 15.4 near Battleboro, North Carolina. The Line of Road Improvements can be accessed using Fountain Park Drive near Rocky Mount, NC and W. Battleboro Ave. in Battelboro, NC. 18. Nature of Activity (Description of project, include all features) CSX Transportation, Inc. (CSXT), a subsidiary of CSX Corporation (CSX), a Virginia Company, intend to construct a new intermodal freight terminal, known as the Carolina Connector Intermodal Rail Terminal (CCX Terminal), a siding to access the terminal and associated reconstruction of former second mainline track in the vicinity of the terminal (Line of Road Improvements). The Project Area is approximately 681 acres and is comprised of the two components, the CCX Terminal and Line of Road Improvements, as shown in Figure 1. The CCX Terminal is generally located along the western edge of Edgecombe County, north of the City of Rocky Mount, and between the existing CSX mainline and Old Battleboro Road. The Line of Road Improvements component is part of the CSXT North End Subdivision, which runs along the county line between Edgecombe County and Nash County, North Carolina, and generally runs parallel to the I-95 corridor. See attached Environmental Report for additional details. 19. Project Purpose (Describe the reason or purpose of the project, see instructions) The purpose of the construction of CCX is to better connect economic centers, relieve highway congestion, and address current and future regional infrastructure and freight distribution needs through intermodal rail transportation. The intent of the reconstruction efforts, such as the Line of Road Improvements, is to increase fluidity of train/freight movement and system -wide capacity improvement. Most of the system -wide improvements involve either extending existing siding tracks or connecting existing sidings to obtain the ability to handle 15,000 feet trains. The CSXT Line of Road Improvements are part of the ongoing infrastructure upgrades underway throughout the CSX system. See attached Enviromental Report for additional details. USE BLOCKS 20-23 IF DREDGED AND/OR FILL MATERIAL IS TO BE DISCHARGED 20. Reason(s) for Discharge Based on the proposed construction of the CCX and the Line of Road Improvements permanent impacts to wetlands, streams, open waters, and riparian buffers will be necessary. The intermodal rail terminal requires a large relatively flat parcel of land to accomodate the lead tracks entering the facility, support/storage tracks, and working tracks for loading and unloading containers. The intermodal terminal also includes paved areas for wheeled parking units, stacked units/containers, employee parking, and operations and maintenance buildings. Impacts to wetlands, streams and open waters are necessary to prepare the site for intermodal terminal construction. Impacts associated with discharges to wetland and streams will be necessary to restore double track to the mainline service route. Additional information is included in the attached Environmental Report. 21. Type(s) of Material Being Discharged and the Amount of Each Type in Cubic Yards: Type Type Type Amount in Cubic Yards Amount in Cubic Yards Amount in Cubic Yards Intermodal Facility = 33,761 yd3 fill Lead Tracks = 4,343 yd3 Second Mainline = 6,955 yd3 22. Surface Area in Acres of Wetlands or Other Waters Filled (see instructions) Acres 6.87 acres permanent wetland impact. or Linear Feet 4,042 linear feet permanent stream impact. 0.22 acre open water impact. 23. Description of Avoidance, Minimization, and Compensation (see instructions) Impacts to waters of the US will be avoided to the maximum extent practicable. Impacts will be minimized by following best management practices, erosion/sedimentation control plan requirements, NPDES permit compliance, etc. Impacts to waters of the US will be mitigated through compensatory mitigation (Environmental Report section 6.0 pp. 71-72. The Swift Creek - Permittee Responsible Mitigation site will provide all the required compensatory mitigation for this project. ENG FORM 4345, OCT 2012 Page 2 of 3 24. Is Any Portion of the Work Already Complete? F]Yes FX-]No IF YES, DESCRIBE THE COMPLETED WORK 25. Addresses of Adjoining Property Owners, Lessees, Etc., Whose Property Adjoins the Waterbody (if more than can be entered here, please attach a supplemental list). a. Address- See attached property owner information. City - State - Zip - b.Address- City - State - Zip - c. Address- City - State - Zip - d. Address- City - State - Zip - a.Address- city - State - Zip - 26. List of Other Certificates or Approvals/Denials received from other Federal, State, or Local Agencies for Work Described in This Application. AGENCY TYPE APPROVAL* IDENTIFICATION DATE APPLIED DATE APPROVED DATE DENIED NUMBER NCDEQ-DWR 401 Water Quality DWR #17-0938 2017-07-28 2017-12-21 * Would include but is not restricted to zoning, building, and flood plain permits 27. Application is hereby made for permit or permits to authorize the work described in this application. I certify that this information in this application is complete and accurate. I further certify that I possess the authority to undertake the work described herein or am acting as the duly authorized agent of the applicant. 4 . SIGNATURE OF APPLICANT DATE SIGNATURE OF AGENT DATE The Application must be signed by the person who desires to undertake the proposed activity (applicant) or it may be signed by a duly authorized agent if the statement in block 11 has been filled out and signed. 18 U.S.C. Section 1001 provides that: Whoever, in any manner within the jurisdiction of any department or agency of the United States knowingly and willfully falsifies, conceals, or covers up any trick, scheme, or disguises a material fact or makes any false, fictitious or fraudulent statements or representations or makes or uses any false writing or document knowing same to contain any false, fictitious or fraudulent statements or entry, shall be fined not more than $10,000 or imprisoned not more than five years or both. ENG FORM 4345, OCT 2012 Page 3 of 3 U.S. ARMY CORPS OF ENGINEERS APPLICATION FOR DEPARTMENT OF THE ARMY PERMIT OMB APPROVAL NO. 0710-0003 EXPIRES: 28 FEBRUARY 2013 33 CFR 325. The proponent agency is CECW-CO-R. Public reporting for this collection of information is estimated to average 11 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of the collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters, Executive Services and Communications Directorate, Information Management Division and to the Office of Management and Budget, Paperwork Reduction Project (0710-0003). Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. Please DO NOT RETURN your form to either of those addresses. Completed applications must be submitted to the District Engineer having jurisdiction over the location of the proposed activity. PRIVACY ACT STATEMENT Authorities: Rivers and Harbors Act, Section 10, 33 USC 403; Clean Water Act, Section 404, 33 USC 1344; Marine Protection, Research, and Sanctuaries Act, Section 103, 33 USC 1413; Regulatory Programs of the Corps of Engineers; Final Rule 33 CFR 320-332. Principal Purpose: Information provided on this form will be used in evaluating the application for a permit. Routine Uses: This information may be shared with the Department of Justice and other federal, state, and local government agencies, and the public and may be made available as part of a public notice as required by Federal law. Submission of requested information is voluntary, however, if information is not provided the permit application cannot be evaluated nor can a permit be issued. One set of original drawings or good reproducible copies which show the location and character of the proposed activity must be attached to this application (see sample drawings and/or instructions) and be submitted to the District Engineer having jurisdiction over the location of the proposed activity. An application that is not completed in full will be returned. (ITEMS 1 THRU 4 TO BE FILLED BY THE CORPS) 1. APPLICATION NO. 2. FIELD OFFICE CODE 3. DATE RECEIVED 4. DATE APPLICATION COMPLETE (ITEMS BELOW TO BE FILLED BYAPPLICAN7) 5. APPLICANT'S NAME 8. AUTHORIZED AGENT'S NAME AND TITLE (agent is not required) First - Tony Middle - Chad Last - Coggins First - Richard Middle - Last - Harmon Company - NCDOT Division 4 Company - Wood Environment & Infrastructure Solutions, Inc E-mail Address - tccoggins@ncdot.gov E-mail Address - richard.harmon@woodplc.com 6. APPLICANT'S ADDRESS: 9. AGENT'S ADDRESS: Address- 509 Ward Boulevard, PO Box 3165 Address- 4021 Stirrup Creek Drive, Suite 100 City - Wilson State - NC Zip - 2789 Country - US City - Durham State - NC Zip - 2770 Country -US 7. APPLICANT'S PHONE NOs. w/AREA CODE 10. AGENTS PHONE NOs. WAREA CODE a. Residence b. Business c. Fax a. Residence b. Business c. Fax 252-640-6427 919-381-1366 919-381-9901 STATEMENT OF AUTHORIZATION 11. 1 hereby authorize, Richard Harmon to act in my behalf as my agent in the processing of this application and to furnish, upon request, supplemental information in support of this permit application. IGNATURE F APP DAYE NAME, LOCATION, AND DESCRIPTION OF PROJECT OR ACTIVITY 12. PROJECT NAME OR TITLE (see instructions) Carolina Connector Intermodal Rail Terminal and Line of Road Improvements, Edgecombe and Nash Counties, NC 13. NAME OF WATERBODY, IF KNOWN (if applicable) 14. PROJECT STREET ADDRESS (if applicable) Beech Branch Address Old Battleboro Road 15. LOCATION OF PROJECT Latitude: ^N 36.01458 Longitude: -W -77.76345 City - Battleboro State- NC Zip- 16. OTHER LOCATION DESCRIPTIONS, IF KNOWN (see instructions) State Tax Parcel ID 386371624400 Municipality Edgecombe County, NC Section - N/A Township - N/A Range - N/A ENG FORM 4345, OCT 2012 PREVIOUS EDITIONS ARE OBSOLETE. Page 1 of 3 17. DIRECTIONS TO THE SITE CCX Intermodal Site: From Raleigh, take US 64 to Rocky Mount. Take US 301 North to College Road. Turn right on College Road. Site is on both sides of College Road Line of Road Improvements: Along the existing mainline from Milepost Al 10.6 in Rocky Mount north to Milepost Al 15.4 near Battleboro, North Carolina. The Line of Road Improvements can be accessed using Fountain Park Drive near Rocky Mount, NC and W. Battleboro Ave. in Battelboro, NC. 18. Nature of Activity (Description of project, include all features) CSX Transportation, Inc. (CSXT), a subsidiary of CSX Corporation (CSX), a Virginia Company, intend to construct a new intermodal freight terminal, known as the Carolina Connector Intermodal Rail Terminal (CCX Terminal), a siding to access the terminal and associated reconstruction of former second mainline track in the vicinity of the terminal (Line of Road Improvements). The Project Area is approximately 681 acres and is comprised of the two components, the CCX Terminal and Line of Road Improvements, as shown in Figure 1. The CCX Terminal is generally located along the western edge of Edgecombe County, north of the City of Rocky Mount, and between the existing CSX mainline and Old Battleboro Road. The Line of Road Improvements component is part of the CSXT North End Subdivision, which runs along the county line between Edgecombe County and Nash County, North Carolina, and generally runs parallel to the I-95 corridor. See attached Environmental Report for additional details. 19. Project Purpose (Describe the reason or purpose of the project, see instructions) The purpose of the construction of CCX is to better connect economic centers, relieve highway congestion, and address current and future regional infrastructure and freight distribution needs through intermodal rail transportation. The intent of the reconstruction efforts, such as the Line of Road Improvements, is to increase fluidity of train/freight movement and system -wide capacity improvement. Most of the system -wide improvements involve either extending existing siding tracks or connecting existing sidings to obtain the ability to handle 15,000 feet trains. The CSXT Line of Road Improvements are part of the ongoing infrastructure upgrades underway throughout the CSX system. See attached Enviromental Report for additional details. USE BLOCKS 20-23 IF DREDGED AND/OR FILL MATERIAL IS TO BE DISCHARGED 20. Reason(s) for Discharge Based on the proposed construction of the CCX and the Line of Road Improvements permanent impacts to wetlands, streams, open waters, and riparian buffers will be necessary. The intermodal rail terminal requires a large relatively flat parcel of land to accomodate the lead tracks entering the facility, support/storage tracks, and working tracks for loading and unloading containers. The intermodal terminal also includes paved areas for wheeled parking units, stacked units/containers, employee parking, and operations and maintenance buildings. Impacts to wetlands, streams and open waters are necessary to prepare the site for intermodal terminal construction. Impacts associated with discharges to wetland and streams will be necessary to restore double track to the mainline service route. Additional information is included in the attached Environmental Report. 21. Type(s) of Material Being Discharged and the Amount of Each Type in Cubic Yards: Type Type Type Amount in Cubic Yards Amount in Cubic Yards Amount in Cubic Yards Intermodal Facility = 33,761 yd3 fill Lead Tracks = 4,343 yd3 Second Mainline = 6,955 yd3 22. Surface Area in Acres of Wetlands or Other Waters Filled (see instructions) Acres 6.87 acres permanent wetland impact. or Linear Feet 4,042 linear feet permanent stream impact. 0.22 acre open water impact. 23. Description of Avoidance, Minimization, and Compensation (see instructions) Impacts to waters of the US will be avoided to the maximum extent practicable. Impacts will be minimized by following best management practices, erosion/sedimentation control plan requirements, NPDES permit compliance, etc. Impacts to waters of the US will be mitigated through compensatory mitigation (Environmental Report section 6.0 pp. 71-72. The Swift Creek - Permittee Responsible Mitigation site will provide all the required compensatory mitigation for this project. ENG FORM 4345, OCT 2012 Page 2 of 3 24. Is Any Portion of the Work Already Complete? F]Yes QNo IF YES, DESCRIBE THE COMPLETED WORK 25. Addresses of Adjoining Property Owners, Lessees, Etc., Whose Property Adjoins the Waterbody (if more than can be entered here, please attach a supplemental list). a. Address- See attached property owner information. City - State - Zip - b.Address- City - State - Zip - c. Address- City - State - Zip - d.Address- City - State - Zip - e. Address- City - State - Zip - 26. List of Other Certificates or Approvals/Denials received from other Federal, State, or Local Agencies for Work Described in This Application. AGENCY TYPE APPROVAL` IDENTIFICATION DATE APPLIED DATE APPROVED DATE DENIED NUMBER NCDEQ-DWR 401 Water Quality DWR #17-0938 2017-07-28 2017-12-21 * Would include but is not restricted to zoning, building, and flood plain permits 27. Application is hereby made for permit or permits to authorize the work described in this application. I certify that this information in this application is complete and accurate. I further certify that I possess the authority to undertake the work described herein or am acting as the duly authorized agent of the applicant. GNA URE O APPLI T E SIGNATURE OF AGENT DATE The Application must be signed by the person who desires to undertake the proposed activity (applicant) or it may be signed by a duly authorized agent if the statement in block 11 has been filled out and signed. 18 U.S.C. Section 1001 provides that: Whoever, in any manner within the jurisdiction of any department or agency of the United States knowingly and willfully falsifies, conceals, or covers up any trick, scheme, or disguises a material fact or makes any false, fictitious or fraudulent statements or representations or makes or uses any false writing or document knowing same to contain any false, fictitious or fraudulent statements or entry, shall be fined not more than $10,000 or imprisoned not more than five years or both. ENG FORM 4345, OCT 2012 Page 3 of 3 CSX CCX Intermodal Rail Terminal and Line of Road Improvements Edgecombe and Nash Counties, North Carolina Project No. 643009004 Appendix F APPENDIX F RIPARIAN BUFFER AUTHORIZATION State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02B .0233 (8)(b), .0243 (8)(b), .0250 (11)(b), .0259 (8)(b), .0267 (11)(c), .0607 (e)(2) – Buffer Authorization FORM: BA 10-2013 FORM: BA 10-2013 Page 1 of 6 Riparian Buffer Authorization Form A. Applicant Information 1. Project Information 1a. Name of project: Carolina Connector Intermodal Rail Terminal and Second Mainline Improvements 1b. County: Edgecombe and Nash 1c. Nearest municipality: Rocky Mount 1d. Subdivision name: N/A 1e. Is the project located in any of North Carolina’s twenty coastal counties? If yes, answer 1f below. Yes No 1f. Is the project located within a NC Division of Coastal Management Area of Environmental Concern (AEC)? Yes No 2. Owner Information 2a. Name on Recorded Deed: CSX Transportation 2b. Deed Book and Page No. 1655/0910 2c. Map Book and Page No. (include a copy of the recorded map that indicates when the lot was created): 2d. Responsible Party (for Corporations): CSX Intermodal Terminals, Inc., and CSX Transportation, Inc. Attn: Matthew L. Adkins 2e. Street address: 351 Thornton Road, Suite 125 2f. City, state, zip: Lithia Springs, GA 30122 2g. Telephone no.: 770-819-2849 2h. Fax no.: 2i. Email address: Matt_Adkins@csx.com 3. Applicant Information (if different from owner) 3a. Applicant is: Agent Other, specify: Owner 3b. Name: 3c. Business name (if applicable): 3d. Street address: 3e. City, state, zip: 3f. Telephone no.: 3g. Fax no.: 3h. Email address: 4. Agent/Consultant Information (if applicable) 4a. Name: Richard Harmon 4b. Business name (if applicable): Amec Foster Wheeler Environment & Infrastructure, Inc. 4c. Street address: 4021 Stirrup Creek Drive, Suite 100 4d. City, state, zip: Durham, NC 27703 4e. Telephone no.: 919-381-1366 4f. Fax no.: 919-381-9901 4g. Email address: Richard.harmon@amecfw.com FORM: BA 10-2013 Page 2 of 6 B. Project Information and Prior Project History 1. Property Identification 1a. Property identification no. (tax PIN or parcel ID): 386371624400 1b. Site coordinates (in decimal degrees): Latitude: 36.018182 Longitude: -77.761737 1c. Property size: 681 acres 2. Surface Waters 2a. Name of nearest body of water to proposed project: Beech Branch 2b. Water Quality Classification of nearest receiving water: Class B; NSW 2c. River basin: Tar-Pamlico 3. Project Description 3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application: The Rocky Mount site is approximately 681 acres and is located along the boundary line between Edgecombe and Nash Counties and wholly within Edgecombe County north of the city of Rocky Mount, northeast of the intersection of US-64 and I-95. The site primarily consists of agricultural land with residential and commercial buildings and woodlands dispersed throughout. College Road, a NCDOT secondary road, bisects the site in the southern portion of the site. Beech Branch, unnamed tributaries and associated wetlands, agricultural/recreational ponds, and agricultural ditches are also present within the site. Two cemeteries and a telecommunications tower are present on the site. 3b. Attach an 8 ½ x 11 excerpt from the most recent version of the USGS topographic map indicating the location of the site. The CCX Intermodal Site On-Site Determination Letter (dated December 7, 2016) and the CSX On-Site Determination Letter (Dated May 31, 2017) include the USGS topographic maps indicating the location of the project site. 3c. Attach an 8 ½ x 11 excerpt from the most recent version of the published County NRCS Soil Survey Map depicting the project site. The CCX Intermodal Site On-Site Determination Letter (dated December 7, 2016) and the CSX On-Site Determination Letter (Dated May 31, 2017) include the published County NRCS Soil Survey Maps indicating the location of the project site. 3d. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property: 4,042 linear feet 3e. Explain the purpose of the proposed project: The Proposed Action is comprised of two components representing two different types of railroad infrastructure: the Carolina Connector Intermodal Rail Terminal; and the Rocky Mount to Bricks Second Mainline reconstruction. 3f. Describe the overall project in detail, including the type of equipment to be used: CSX Intermodal Terminals, Inc. (CSXIT) and CSX Transportation, Inc. (CSXT), subsidiaries of CSX Corporation (CSX), a Virginia Company, intend to construct a new intermodal freight terminal, known as the Carolina Connector Intermodal Rail Terminal (CCX Terminal), and associated reconstruction of former second mainline track, known as the Rocky Mount to Bricks Second Mainline Improvements (Second Mainline). The Project Area is approximately 681 acres and is comprised of the two components, the CCX Terminal and Second Mainline. The CCX terminal consists of approximately 635 acres and is generally located along the western edge of Edgecombe County, north of the City of Rocky Mount, and between the existing CSX mainline and Old Battleboro Road. The Second Mainline component is part of the CSXT North End Subdivision, which runs along the county line between Edgecombe County and Nash County, North Carolina, and generally runs parallel to the I-95 corridor. The Carolina Connector Intermodal Rail Terminal will consist of a lead track north and south of the facility diverging off the mainline service route into the intermodal rail terminal. The lead tracks will extend 1.2 miles to the north and 2.3 miles to the south. CSXT plans to restore double track to the mainline service route between Milepost A117.5 to A104.9, within an approximately 158 acre corridor. FORM: BA 10-2013 Page 3 of 6 4. Jurisdictional Determinations 4a. Have jurisdictional wetland or stream determinations by the Corps or State been requested or obtained for this property/ project (including all prior phases) in the past? Yes No Unknown Comments: A request for Verification of Jurisdictional Determination (JD) was submitted, on behalf of CSX, to the USACE Raleigh Regulatory Field Office for the delineated wetland areas within the CCX section of the site. The USACE Action ID is SAW -2016-02338. The USACE JD review was conducted on October 19 and December 8, 2016, by the USACE and on October 19, 2016 and 27, 2016. The Preliminary JD and Approved JD have not been issued for the project site to date. NCDWR completed onsite determinations for the Intermodal Site on 10/20/16 and 10/27/16 (RO Stream/Buffer Tracking Number #16-402) and the Line of Road on 4/28/17 (RO Stream/Buffer Tracking Number #17-163). 4b. If yes, who delineated the jurisdictional areas? Name (if known): Amec Foster Wheeler Agency/ Consultant Company: Amec Foster Wheeler Other: 4c. If yes, list the dates of the Corps jurisdictional determinations or State determinations and attach documentation. The USACE JD review was conducted on October 19 and December 8, 2016, by the USACE and on October 19, 2016 and 27, 2016. The Preliminary JD and Approved JD have not been issued for the project site to date. USACE Action ID SAW -2016-02338. NCDWR completed onsite determinations for the Intermodal Site on 10/20/16 and 10/27/16 (RO Stream/Buffer Tracking Number #16-402) and the Line of Road on 4/28/17 (RO Stream/Buffer Tracking Number #17-163). 5. Project History 5a. Have permits or certifications been requested or obtained for this project (including all prior phases) in the past? Yes No Unknown 5b. If yes, explain and detail according to “help file” instructions. NCDWR issued the Approval of Individual 401 Water Quality Certification and Tar-Pamlico Riparian Buffer Impacts with Additional Conditions (DWR# 17-0938) on December 21, 2017. The USACE Action ID SAW-2016-02338 was issued for the project. The Preliminary JD and Approved JD have not been issued for the project site to date. No permits or certifications have been requested or obtained for the project. 6. Future Project Plans 6a. Is this a phased project? Yes No 6b. If yes, explain. The phase 1 facility infrastructure will consist of operational facilities, chassis parking, two yard (storage) tracks, and five processing (loading/unloading) tracks with gantry cranes, with a phase 2 potential to expand to 12 total yard tracks (Storage and loading/unloading) with processing track length extensions and additional tracks for locomotive and car repair. The Carolina Connector Intermodal Rail Terminal will consist of a lead track north and south of the facility diverging off the mainline service route into the intermodal rail terminal. The lead tracks will extend 1.2 miles to the north and 2.3 miles to the south. CSXT plans to restore double track to the mainline service route between Milepost A117.5 to A104.9, within an approximately 158 acre corridor. FORM: BA 10-2013 Page 4 of 6 C. Proposed Impacts Inventory 1. Buffer Impacts 1a. Project is in which protected basin? Neuse Tar-Pamlico Catawba Randleman Jordan Goose Creek 1b. Individually list all buffer impacts below. If any impacts require mitigation, then you MUST fill out Section D of this form. Buffer impact number – Permanent (P) or Temporary (T) Reason for impact Type of impact (exempt, allowable, allowable w/ mitigation) Stream name Buffer mitigation required? Zone 1 impact (sq ft) Zone 2 impact (sq ft) B1 P T Rail terminal Allowable with Mitigation SC Yes No 9,591 4,643 B2 P T Rail terminal Allowable with Mitigation SD Yes No 32,856 23,455 B5 P T Rail terminal Allowable with Mitigation SE Yes No 84,916 57,615 B7 P T Rail terminal Allowable with Mitigation SG Yes No 18,916 12,830 B8 P T Rail crossing Allowable with Mitigation S12/SI Yes No 6,261 5,241 B9 P T Rail crossing Allowable with Mitigation S13 Yes No 15,860 5,524 Total buffer impacts 168,400 109,308 1c. Comments: Riparian Buffer Impact Sheets 1 through 5 (attached herein) show the proposed buffer impact areas (Zones 1 and 2) within the project site. D. Impact Justification and Mitigation 1. Avoidance and Minimization 1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing project. Impacts to waters of the US will be avoided to the maximum extent practicable. An extensive Alternative Analysis study was conducted on twelve potential sites for the intermodal facility to determine the least environmentall damaging practicable alternative (LEDPA). Five design altermatives were evaluated for the preferred altermative. The final design avoids impacts to environmentally sensiti ve areas inlcuding minimizing impacts to wetlands, streams, and riparian buffers for the intermodal terminal facility and the maximum extents possible. 1b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques. Impacts will be minimized by following best management practices, erosion/sedimentation control plan requirements, NPDES permit compliance, etc. Areas used for temporary construction will be returned to pre-construction conditions. FORM: BA 10-2013 Page 5 of 6 2. Buffer Mitigation 2a. Will the project result in an impact within a protected riparian buffer that requires buffer mitigation? Yes No 2b. If yes, then identify the square feet of impact to each zone of the riparian buffer that requires mitigation and calculate the amount of mitigation required in the table below. Zone Reason for impact Total impact (square feet) Multiplier Required mitigation (square feet) Zone 1 Rail terminal and/or railroad crossing impacts 168,400 3 (2 for Catawba) 502,200 Zone 2 Rail terminal and/or railroad crossing impacts 109,308 1.5 163,962 Total buffer mitigation required: 666,162 2c. If buffer mitigation is required, is payment to a mitigation bank or NC DMS proposed? Yes No 2d. If yes, attach the acceptance letter from the mitigation bank or NC DMS. 2e. If no, then discuss what type of mitigation is proposed. The proposed Swift Creek – Permittee Responsible Mitigation Plan (Mitigation Project) located near Leggett in Edgecombe County will provide the required buffer mitigation credits. 2f. Comments: See Appendix G of the Carolina Connector Rail and Second Mainline Improvements Environmental Report for details on the PRMP project. E. Diffuse Flow Plan All buffer impacts and high ground impacts require diffuse flow or other form of stormwater treatment. Include a plan that fully documents how diffuse flow will be maintained. If a Level Spreader is proposed, attach a Level Spreader Supplement Form. If due to site constraints, a BMP other than a level spreader is proposed, please provide a plan for stormwater treatment as outlined in Chapter 8 of the NC Stormwater BMP Manual and attach a BMP Supplement Form. Diffuse flow Other BMP F. Supplementary Information 1. Environmental Documentation 1a. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land? Yes No 1b. If you answered “yes” to the above, does the project require preparation of an environmental document pursuant to the requirements of the National or State (North Carolina) Environmental Policy Act (NEPA/SEPA)? Yes No 1c. If you answered “yes” to the above, has the document been finalized by the State Clearing House? (If so, attach a copy of the NEPA or SEPA final approval letter.) Comments: Yes No 2. Violations 2a. Is the site in violation of DWR Wetland Rules (15A NCAC 02H .0500), Isolated Wetland Rules (15A NCAC 02H .1300), DWR Surface Water or Wetland Standards, or Riparian Buffer Rules (15A NCAC 02B .0200)? Yes No 2b. Is this an after-the-fact permit application? Yes No 2c. If you answered “yes” to one or both of the above questions, provide an explanation of the violation(s): FORM: BA 10-2013 Page 6 of 6 __________________________ Applicant/Agent's Printed Name ________________________________________________ Applicant/Agent's Signature (Agent's signature is valid only if an authorization letter from the applicant is provided.) __________ Date Send 3 complete sets of this form and accompanying documents to the following: For government transportation projects sent by First Class Mail via the US Postal Service: OR For government transportation projects sent by delivery service (UPS, FedEx, etc.): NC DWR, Transportation Permitting Unit 1617 Mail Service Center Raleigh, NC 27699 - 1617 NC DWR, Transportation Permitting Unit 512 N. Salisbury Street Raleigh, NC 27604 For all other projects sent by First Class Mail via the US Postal Service OR For all other projects sent by delivery service (UPS, FedEx, etc.): Karen Higgins NCDW R – 401 & Buffer Permitting Branch 1617 Mail Service Center Raleigh, NC 27699 - 1617 Karen Higgins NCDW R – 401 & Buffer Permitting Branch 512 N. Salisbury Street Raleigh, NC 27604 Diffuser Flow Plan: Where ponds abut and discharge to riparian buffers, ponds are equipped with level spreaders that release water from the first flush (1-inch rainfall event) from the pond in a period of two to five days. Wet Detention Ponds 1, 2, 3, 4 & 5 are equipped with level spreaders and Ponds 2, 3, 4 & 5 also are equipped with a filter strip at the outfall. The level spreaders are sized to meet the requirement of 10 feet of width for every cfs. High flow bypasses are included to safely control and direct high flows from the ponds and release them in ways that are not harmful to the adjacent land and minimize buffer/wetland disturbance. This means that high flows are released from the pond’s riser either into the new stormwater piping for the project or to riprap protected areas at the ends of the proposed culverts, with the exception of Pond 5, where the level spreader is sized for the larger storm events. This helps minimize the overall impacts to the wetlands, streams, and provides a stable point of discharge. Detailed information is in the attached Stormwater Management Plan for the Carolina Connector Intermodal Rail Terminal (CCX). CCDD AA BB S13A S14 GAINOR AVE MACKTOWN STVIVERETTE AVEMARRIOTT RD E BATTLEBORO AVEUS 301 NO R T H N A S H DAN I E L S A V E PRATT PL O W E N S CI R JB L N MILBOUR N E ST CEMETE R Y D R E BRIDGES STCONYER LNW BRIDGES STW BATTLEBORO AVEDENZEL LNDANIELS AVEPEARSALL ST 2 4 5 1 3 I0 1,400700Feet Legend CSX Project Area Limits of Disturbance Stream Pond Wetland Riparian Buffer Impacts Riparian Buffer Zone 1 Riparian Buffer Zone 2 Roads Map Index Imagery Source: NC OneMap I 0 10.5 Miles P:\Environmental\2012 + Projects\64300-9004 - CSXIT Carolina Connector\Environmental Assessment\GIS\RiparianBufferImpacts.mxdCSX Carolina ConnectorIntermodal Rail Terminaland Second Mainline ImprovementsEdgecombe County, North Carolina The map shown here has beencreated with all due andreasonable care and is strictly foruse with Wood Environment &Infrastructure Solutions, Inc(Wood) project number643009004. Wood assumes noliability, direct or indirect,whatsoever for any such thirdparty or unintended use. Job No. 64300-9004 Drawn By: BWS Reviewed By: RH Date: 12/7/2018 Riparian Buffer Impacts MapSheet 1 of 5 720 Gracern Road, Suite 132Columbia, SC 29210 USA(803)-798-1200 W-LT M-LT J K L IMN AA XYZ S13A S13 S12SI S14 BATTLEBORO-LEGGETTRDVIVERETTE AVEUS 301NORTH NASH MORNING S TAR CH RD DAN I E L S AVE MAR I L Y N S T CEMETERY DR OLD BATTLEBORO RDE BATTLEBORO AVEREDOAK-BAT TLEBORORD NASH 2 4 5 1 3 I0 1,400700Feet Legend CSX Project Area Limits of Disturbance Stream Pond Wetland Riparian Buffer Impacts Riparian Buffer Zone 1 Riparian Buffer Zone 2 Roads Map Index Imagery Source: NC OneMap I 0 10.5 Miles P:\Environmental\2012 + Projects\64300-9004 - CSXIT Carolina Connector\Environmental Assessment\GIS\RiparianBufferImpacts.mxdCSX Carolina ConnectorIntermodal Rail Terminaland Second Mainline ImprovementsEdgecombe County, North Carolina The map shown here has beencreated with all due andreasonable care and is strictly foruse with Wood Environment &Infrastructure Solutions, Inc(Wood) project number643009004. Wood assumes noliability, direct or indirect,whatsoever for any such thirdparty or unintended use. Job No. 64300-9004 Drawn By: BWS Reviewed By: RH Date: 12/7/2018 Riparian Buffer Impacts MapSheet 2 of 5 720 Gracern Road, Suite 132Columbia, SC 29210 USA(803)-798-1200 P F E GH Q J K L I NNS10S12SI SD SESGA SG SEE ES SEC SED S11A S23 1 3 2 4 OLD BATT L E B O R O R DCOLB ER T PA TH F L Y E P A T H 2 4 5 1 3 I0 1,400700Feet Legend CSX Project Area Limits of Disturbance Stream Pond Wetland Riparian Buffer Impacts Riparian Buffer Zone 1 Riparian Buffer Zone 2 Roads Map Index Imagery Source: NC OneMap I 0 10.5 Miles P:\Environmental\2012 + Projects\64300-9004 - CSXIT Carolina Connector\Environmental Assessment\GIS\RiparianBufferImpacts.mxdCSX Carolina ConnectorIntermodal Rail Terminaland Second Mainline ImprovementsEdgecombe County, North Carolina The map shown here has beencreated with all due andreasonable care and is strictly foruse with Wood Environment &Infrastructure Solutions, Inc(Wood) project number643009004. Wood assumes noliability, direct or indirect,whatsoever for any such thirdparty or unintended use. Job No. 64300-9004 Drawn By: BWS Reviewed By: RH Date: 12/7/2018 Riparian Buffer Impacts MapSheet 3 of 5 720 Gracern Road, Suite 132Columbia, SC 29210 USA(803)-798-1200 S-LTT-LTO AB C P E R U NN S7 SC SB SD S23 S9 S8COLLEGE RDCOLLEGERD NASHN WESLEYAN BLVD NASH TECHNOLOGY PKWY WINDYWOOD LN 2 4 5 1 3 I0 1,400700Feet Legend CSX Project Area Limits of Disturbance Stream Pond Wetland Riparian Buffer Impacts Riparian Buffer Zone 1 Riparian Buffer Zone 2 Roads Map Index Imagery Source: NC OneMap I 0 10.5 Miles P:\Environmental\2012 + Projects\64300-9004 - CSXIT Carolina Connector\Environmental Assessment\GIS\RiparianBufferImpacts.mxdCSX Carolina ConnectorIntermodal Rail Terminaland Second Mainline ImprovementsEdgecombe County, North Carolina The map shown here has beencreated with all due andreasonable care and is strictly foruse with Wood Environment &Infrastructure Solutions, Inc(Wood) project number643009004. Wood assumes noliability, direct or indirect,whatsoever for any such thirdparty or unintended use. Job No. 64300-9004 Drawn By: BWS Reviewed By: RH Date: 12/7/2018 Riparian Buffer Impacts MapSheet 4 of 5 720 Gracern Road, Suite 132Columbia, SC 29210 USA(803)-798-1200 O-LTP-LT S-LTT-LT O A RU S7 SC S6S9 S8 INSTRUMENT DR NASHCLIFF LNN CHURCH S T N A S HKASEY LNTANNER RDFOUNTAIN SCH RDN WESLE Y A N B L V D N A S HFOUNTAIN PARK DRN CHURCH ST NASH N WESLEYAN B L V D N A S H 2 4 5 1 3 I0 1,400700Feet Legend CSX Project Area Limits of Disturbance Stream Pond Wetland Riparian Buffer Impacts Riparian Buffer Zone 1 Riparian Buffer Zone 2 Roads Map Index Imagery Source: NC OneMap I 0 10.5 Miles P:\Environmental\2012 + Projects\64300-9004 - CSXIT Carolina Connector\Environmental Assessment\GIS\RiparianBufferImpacts.mxdCSX Carolina ConnectorIntermodal Rail Terminaland Second Mainline ImprovementsEdgecombe County, North Carolina The map shown here has beencreated with all due andreasonable care and is strictly foruse with Wood Environment &Infrastructure Solutions, Inc(Wood) project number643009004. Wood assumes noliability, direct or indirect,whatsoever for any such thirdparty or unintended use. Job No. 64300-9004 Drawn By: BWS Reviewed By: RH Date: 12/7/2018 Riparian Buffer Impacts MapSheet 5 of 5 720 Gracern Road, Suite 132Columbia, SC 29210 USA(803)-798-1200 an Water Resources ENVIRONMENTAL QUALITY CSX Transportation Attn: Richard K. Nath 500 Water Street, J275 Jacksonville, FL 32202 17INEUT Governor DONALD R. VAN DER VAART Secretary S. JAY ZIMMERMAN Director December 7, 2016 RO STREAM /BUFFER TRACKING NUMBER #16-402 Edgecombe County Subject: On -Site Determination for Applicability to the Tar -Pamlico Basin Riparian Buffer Rules (15A BCAC 02B .0259) Subject Property/ Project Name: CCX Intermodal Site Address/Location: College Road, Rocky Mount Stream(s) Evaluated: UTs to Beech Branch and Compass Creek Determination Date: 10/20/16 & 10/ 27/16 Staff: Jennifer Burdette Determination Type: Buffer: Stream: Neuse (15A NCAC 02B .0233) Intermittent/Perennial Determination Tar -Pamlico (15A NCAC 02B .0259) Soil Survey Catawba (15A NCAC 02B.0243) SK Jordan (15A NCAC 02B .0267) (governmental and/or interjurisdictional projects) Flows onto site Randleman (15A NCAC 02B .0250) X Goose Creek (15A NCAC 02B .0605-.0608) SI - Beech Branch Stream E/I/Pl Not Subject Subject Start@ Stop@ Soil Survey USGS Topo SK P X Flows onto site Confluence with SI X X SI - Beech Branch P X Throughout X X SG(B)2 1 X Pond I DWR flag X X Pond 2 Pond X Connected to subject channel downstream X X C2 E X X SGA I SGA -1A Confluence with SG X Pond 4 Pond X No channel or pond depicted Ditch 2 E X X Pond 3 Pond X Not connected to subject channel upstream or downstream X Ditch 3 E X I X State of North Carolina I Environmental Quality I Water Resources 1617 Mail Service Center Raleigh, North Carolina 27699-1617 919 807 6300 CCX Intermodal Site Edgecombe County December 7, 2016 Page 2 of 3 Stream E/I/Pl Not Subject Subject Start@ Stop@ Soil Survey USGS Topo SE (A)z P X Throughout X X SD I/P X SD -45.5 I Flows off-site X X Pond 1 Pond X Not connected to subject channel upstream or downstream Ditch 1 E X X Ditch 4 E X X SF I SF -8 Flows off-site X SB I X SB -1 SB -24 X X SC I 1 i I SC -1 Flows off-site X X 1E/11P = Ephemeral/Intermittent/Perennial 2 By Division of Water Resources determination letter (RRO #16-309) dated September 26, 2016 The Division of Water Resources has determined that the streams listed above and included on the attached maps signed by JAB and dated 12/7/16 have been located on the most recent published NRCS Soil Survey of Edgecombe County, North Carolina and/or the most recent copy of the USGS Topographic map at a 1:24,000 scale and evaluated for applicability to the Tar -Pamlico Basin Riparian Buffer Rule. Each stream that is checked "Not Subject" has been determined to not be at least intermittent or not present on the property. Streams that are checked Subject" have been located on the property and possess characteristics that qualify them to be at least intermittent streams. There may be other streams or features located on the property that do not appear on the maps referenced above but may be considered jurisdictional according to the US Army Corps of Engineers and subject to the Clean Water Act. This on-site determination shall expire five (5) years from the date of this letter. Landowners or affected parties that dispute a determination made by the DWR may request a determination by the Director. An appeal request must be made within sixty (60) calendar days of date of this letter to the Director in writing. If sending via US Postal Service: c/o Karen Higgins DWR — 401 & Buffer Permitting Branch 1617 Mail Service Center Raleigh, NC 2 7699-1 61 7 If sending via delivery service (UPS, FedEx, etc.): clo Karen Higgins DWR — 401 & Buffer Permitting Branch 512 N. Salisbury Street Raleigh, NC 27604 This determination is final and binding as detailed above, unless an appeal is requested within sixty (60) days. This determination only addresses the applicability to the buffer rules and does not approve any activity within the buffers. The project may require a Section 404/401 Permit for the proposed activity. Any inquiries regarding applicability to the Clean Water Act should be directed to the US Army Corps of Engineers Raleigh Regulatory Field Office at (919)-554-4884. If you have questions regarding this determination, please feel free to contact Jennifer Burdette at (919) 807-6364. Sincerely, Karen Higgins, Supervisor 401 & Buffer Permitting Branch CCX Intermodal Site Edgecombe County December 7, 2016 Page 3 of 3 cc: RRO DWR File Copy Richard Harmon, Amec Foster -Wheeler, 4021 Stirrup Creek Drive, Ste 100, Durham, NC 27703 R C. 04 LL 04 Off C) w cn ZOO, Is x c f hLUo 00 OL i 1 5D Q a a o on 60, 110 N y w-6 LLL -0N W , ' r;;a:,;. r /-" T goes W°off o U in j , s tol o LL let c°Eu+ ca j \ Z o o >,o a CL CD OLcnm V c Ec-- o Vto v 81 >,N O • ! x j , _ c•. E°o v, oEo C', L 11 N M f0 N i5 / IA - -• :,. •(,' d , QJlilt CONFIDENTIAL r The map shown here has been created with all due and _ reasonable care. Locations of all features on this map were collected from field reconnaissance and desktop AvA analysis. This map has not been certified by a licensed `V� ,. land surveyor and any third party use of this map comes without warranties of any kind. AM EC Foster Wheeler assumes no liability, direct or indirect, whatsoever for any NIP such third party or unintented use, - i This map is preliminary and subject to change following USACE & NCDEQ verification. g ,! r Ly r! YiV++ D• J SGA A _ _. ti• � S� 111136h 2 - UPS 11a r +1 *A6 s Pond 3 AvA •r r � i� •,tri A YA Ditch 3 A tt VO Wag �f ISE AKAGA . l ' AA t. AA t � rf! ha. WPI' ]itch 1 A AYA Ditch 4 A v4,I ' ff t _ 1h 4 0 1.000 2,000 Peet �_ r„ h �4 Ai N Project Boundary CCX Intermodal Site amec Stream NRCS Soils Map � � foster Wetland Edgecombe County, NC Wheeler Wetland 1 Stream Breakpoint Nate: This figure is for reference only. PROJECT NO: 643009004,0001 [TATE. 11/22/2016 P:ITransportationlProjectslRaiRCSX\Central Carolina Intermodal FacilitylGISIGIWSX.mxd, User: jason.hightower: Date: 11/16/2016 10:18:36 AM, Checke by RGH Date: 10120116 P:lTransportationlProjects\RaiRCSMCentral Carolina intermodal Facility\GlS%GlMCSX.mxd, User: }ason.hightower; Date: 11111201& 2:21:02 PM, Checke by: RGH Date: 10120/16 VV,rre°r Resources CSXI, Inc. Attn: Mr. Matt Adkins 500 Water Street, J-25 South Jacksonville, FL 32216 ROY CGOPLR. MICHAI_ L S. REGAN S. JAY LIMMLRMAN May 31, 2017 RO STREAM /BUFFER TRACKING NUMBER #17-163 EDGECOME County Subject: On -Site Determination for Applicability to the Tar -Pamlico Riparian Buffer Rules and Water Quality Standards (15A BCAC 02B .0259) Subject Property/ Project Name: CSX Line of Road Address/Location: Adjacent to CSX Railroad between North of Whitakers and North of Battleboro Stream(s) Evaluated: UT to Fishing Creek & UTs to Swift Creek Determination Date: April 28, 2017 Staff: Jennifer Burdette Determination Type: Buffer: Stream: ❑ Neuse (15A NCAC 02B .0233) ® Intermittent/Perennial Determination ❑ Tar -Pamlico (15A NCAC 02B .0259) (where local buffer ordinances apply) ❑ Catawba (15A NCAC 02B .0243) ❑ Jordan (15A NCAC 02B .0267) (governmental and/or interjurisdictional projects) ❑ Randleman (15A NCAC 02B .0250) ❑ Goose Creek (15A NCAC 02B.0605-.0608) State of North Carolina I Environmental Quality I Water Resources 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 919 807 6300 k CSXI, Inc. Buffer Determination Tracking # 17-163 Page 2 of 3 Stream E/1/131 Not Subject Subject Start@ Stop@ Soil Survey USGS Topo CC Wetland X X X DD Not present X X X Stream Segment within Swift Creek Swamp Swamp X X Swift Creek P X throughout X X HHZ P X throughout X X GG Swamp X I X X S-19 P X throughout X X WL -MM3 P X throughout X X WL -MM Ditch Ditch X I X 1E/1/P = Ephemeral/Intermittent/Perennial 2 Intercepted by and re-routed into western railroad ditch to Swift Creek 3 Impounded by beaver; buffer begins at elevation of the top of the beaver dam The Division of Water Resources has determined that the feature(s) listed above and included on the attached map signed by Jennifer Burdette on May 31, 2017 are located on the most recent published MRCS Soil Survey of Edgecombe County, North Carolina (1979) and/or the most recent copy of the Enfield & Whitakers, NC (2016) USGS Topographic maps at a 1:24,000 scale and evaluated for applicability to the Tar -Pamlico Riparian Buffer Rule. Each stream that is checked "Not Subject" has been determined to not be at least intermittent or not present on the property. Streams that are checked "Subject" have been located on the property and possess characteristics that qualify them to be at least intermittent streams. There may be other streams or features located on the property that do not appear on the maps referenced above but may be considered jurisdictional according to the US Army Corps of Engineers and subject to the Clean Water Act. This on-site determination shall expire five (5) years from the date of this letter. Landowners or affected parties that dispute a determination made by the DWR may request a determination by the Director. An appeal request must be made within sixty (60) calendar days of date of this letter to the Director in writing. If sending via US Postal Service: c/o Karen Higgins DWR — 401 & Buffer Permitting Branch 1617 Mail Service Center Raleigh, NC 2 7699-1 61 7 If sending via delivery service (UPS, FedEx, etc.): clo Karen Higgins DWR — 401 & Buffer Permitting Branch 512 N. Salisbury Street Raleigh, NC 27604 CSXI, Inc. Buffer Determination Tracking # 17-163 Page 3 of 3 This determination is final and binding as detailed above, unless an appeal is requested within sixty (60) days. This determination only addresses the applicability to the buffer rules and does not approve any activity within the buffers. The project may require a Section 404/401 Permit for the proposed activity. Any inquiries regarding applicability to the Clean Water Act should be directed to the US Army Corps of Engineers Raleigh Regulatory Field Office at (919)-554-4884. If you have questions regarding this determination, please feel free to contact Jennifer Burdette at (919) 807-6364. Sincerely, W,M 6 e� Karen Higgins, Supervisor 401 & Buffer Permitting Branch cc: Josh Witherspoon, AMSC Foster -Wheeler, 4021 Stirrup Creek Drive, Ste 100, Durham, NC 27703 RRO DWR File Filename: CSX Line of Road(Edgecombe)_TAR_StreamDet.docx UZ%CgS Af A P 1 .*�f-- Ir �- '`��i�_ � -� +c. V i ' � y r o-�r--�•,`_- �' / �- _ - `,f„_ ` fit„ IT ` -AL \� r Esc 1 /rf Old Bricks , Com 125, �e- , (Sqb .- its +sG"!`Ga r 1 psi WL- A4 jDikA ION 8P-Avg7g IMPOUAIDMENT CGA/F4 V E Alco AXCA VPSTP-CAM CSX L1A1EoFk6AP 0-17-)�3 U,56 5 144P � Tempt( Cem �. r`{ .-' IV CSX LaN9: 1 FROAP 41-7-163 USG ' MAP 3 -ELI- -.-ice y+- � moi• i. �- - -. r _ .� -L— -ME: ��.,. lr� � !,\_ � �s•.�- �- ��= i� � 1�-` �r — .,. � �� — _Is. y� ice' �_ -�- - �'- �..--_'%1 �• ' ""-` - �"- `�`^. ��. �`-�•-�'�— _ - .., �`~� �. ,.-- f 1 ���.-'�.,. -6- r._�_ op"ll, spilill CSXL1A1EDFR4AD X17 -1L3 use -IS MAPF �- �- � �"- J "�A-� �- ,. � - � -rte -�+�' -�s- �- _ -►�• -lw ..-... .__. --~-•� ��4i^. 1 _� _ ` £" r 4�• i _ mar �y -IM• _i", .. � .++- � � L� �i� _ �.`_ry_.,� � L ; '- Y� �.1- X64 C � , . PDpe :J 1 em -` -est- -� SO- r- x _ �SALL SS L 7rt D '� o -�` Gerry { +' ttlebara I / ''� � Morrains CrossroadsRUC, KY MOUNT star cem i ebur - v ' 115 EDGECOMBE COUNTY,#R R# + SHEET NLJM LINE orl i ARM 1µM * ; ^ a+r _ r ^ , r � - r Ile { . •� .�. � # * ,� �� � f � l �' Crete !i .Ra StB Wh AaA 9� Y . • • � ' x - ..r 7a8 Ro T 3pi AaA NoB • Sk8 Wk8 9. 0 Fi o a�y�+fit i _ �i..Y. a�• t , - n �° 1 c aA RaA Bricks Wk8 r StB Ro IRo $t6 y AaA ZI AaA We dQ aA _ r I Ra AaA GoA CeB 4ik k yiek r �Ary� �� StB _ rl, s y � � AaA �0Y Cy �.. AaA AaA . - Jo . AaA Jo 4^+�.� , Mos k -'a1 CoA 3}l °9 Ca ppg f GoA �a& 1.6 a� CoA fVo$ 12 Scate 1:20000 a 2 37t1 Coo FEET .5 �kk ,� r a ` 301 Nos k i NoBT LY Ra ' C ��; a �,�-�x�sjty NoA Ar NDB a . dl� LY GoAr NoAMR 7 } 41-2 GoA Fl a Ire Y NoA F GoA GoA WaB 0 a a NoA 1 � 14' " t1 Ra GoA Ra { NUB, N Y i 67� a.. H Noe rF Na r. Nob G. WaB i - w.. NUB Y QQ NoSr O R o s .. Fsf� r ° -• AaA Aa was e Me ap Aa.A AaA AaA � de mi) d) / i 5)3 5 00C 0 1 0-51L-alc tlrR,�),qj) -o /� -)t 2 369000 FEET •-;T, m t� 2 368 000 FEET I �I [Joins inset sheet 2 ]) f� r` 3000 AND 2000.400T GRID TICKS e. JT A aA\ 4 # L i:0 TaB �1e A.IA f aB e p Gyr Ro Wks Wk6 y A a A ' W:B ;•}c'_,Y .. .. WkB- NoP GoA No NoA llp6 Was NoA was NoA GoA Ra - Ly GSA 'RU NbB VA i1 Ra Wa6' DPA P._A GoA— �- Was 1 NOB G[ GoA Ra NnA Raµ ` NoA B R (. oA +r JOA WaE 11 11 NoA I { f2 a c•r1 Nab ,/ NoA / Ra '+ GoA LY NoA Wal F ., a: R a i =,A AYES f Gr AVA AYA NoA _ GoAl WaB �Y _ •! fi 5i n �* 1 iExA A CIO `t rT•'11, MWGoA WaB NoA t� B ' ORiJ hoA Ra Ra / NcH wl d f}a GoA 97 a _NOW 3 ' y Gr AYA Ra�A Ra } AYA Na BxA AuF7 NOA ,4_•.�- et'.;:- u .. `�. G 2370 i'O0FEE1 (Joins sheer (5)--- `- NDA Nob Nog ----- - --- fN 1 55+0060+00 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 VAL 6060+13 EMT1 5954+92EMT1 6008+14SEE DRAWING NO. ES-321MATCH LINESEE DRAWING NO. ES-319MATCH LINESEE DRAWING NO. ES-334 MATCH LINE SEE DRAWING NO. ES-307 MATCH LINE PROP. ST06 TRACK PROP. ST07 TRACK PROP. PT04 TRACK PROP. PT05 TRACK PROP. PT06 TRACK PROP. PT07 TRACK PROP. PT08 TRACK PROP. PT08 TRACK PROP. GRAVEL ACCESS DRIVE 3862-56-2216 CSX TRANSPORTATION, INC. 3862-67-2716 CSX TRANSPORTATION, INC. P/L PROP. 10" UD PROP. 10" UD PROP. AIR LINE (TYP.) PROP. C/L DITCH PROP. C/L DITCH 37 RIM=127.13 36RIM=127.45PROP. 8" UD 35RIM=127.77 PROP. 15" UD 30 RIM=127.14 PROP. 48" STM. CULVERT HW1 INV=118.17 125 125 125 127 127 124 124 125 125 125 125 125 127 126 123 123 127126 121 126 126 126 125 125 126 125 124 124 126 125 123 123 125 126 127 PROP. HML (TYP.) RIM=127.33 41 PROP. 12" UD 127 125 122 127 127 PROP. C/L DITCH 120120118118EX. GRAVEL (TRM) EX. C/L DITCH (TRM) PROP. GRAVEL ACCESS DRIVE EX. GRAVEL (TRM) EX. COMMUNICATION TOWER (TRM) HW44 HW45 INV=117.54 INV=117.58 PROP. 48" STM. PROP. GRAVEL ACCESS DRIVE 120117 (FILL TO ELEVATION 120.5) EX. DITCH (TO BE FILLED) (TO BE FILLED) EX. DITCH EX. DITCH (TRM) 12 5 122 123 12412612 6 121 120121122123119120 1 2 1 122 1231201201251191191 2 1 121122122122122 1231231 2 4124126126 120 12 011 81181 1 7118120 119 RR RR RR RR RR RR RECP RECPPS RR PS OUTFALL STORMWATER GRADING LIMITS (TYP.) PS RECP STREAM/WETLAND PROTECTIVE FENCE (TYP.) STREAM/WETLAND PROTECTIVE FENCE (TYP.) PROTECTION ROCK CHANNEL RR ROCK CHANNEL PROTECTION PS PS PS with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78304/12/201910:14:05 AMJ:\20180935\Dgn\04Sheets\13-Erosion Control Plan\ES-301-344.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING LEGEND PROPOSED BOLLARD EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER PROPOSED OVERHEAD ELECTRIC EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING EDGE OF GRAVEL EXISTING EDGE OF PAVEMENT/CURB EXISTING UTILITY PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT PROPOSED COMMUNICATION LINE XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED UNDERGROUND ELECTRIC PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN XX GL RR ROCK LINED DITCH VEGETATIVE DITCH LIMITS OF DISTURBANCE PS PERMANENT SEEDING RECP ROLLED EROSION CONTROL PRODUCT LIMITS OF GRADING FLOW ARROW STREAM/WETLAND PROTECTION FENCE ROCK CHANNEL PROTECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES SHALL CONTINUE THROUGH THE BENCH TO THE TOP OF THE SLOPE ABOVE THE BENCH. 6. GRASS-LINED DITCHES SHALL BE PROVIDED WITH EROSION CONTROL MATTING TO THE TOP OF DITCH SLOPE. WHERE BENCHING OCCURS, THE MATTING ALL SEEDED AREAS 3:1 AND STEEPER SHALL BE PROVIDED WITH EROSION CONTROL MATTING.5. MULCH. 4. ANY DISTURBED AREA LEFT EXPOSED AND IDOL FOR A PERIOD GREATER THAN 14 DAYS SHALL BE STABILIZED WITH MULCH OR TEMPORARY SEEDING WITH EROSION CONTROL, ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE IMPLEMENTED TO CONTROL OR TREAT THE SEDIMENT SOURCE. 3. EROSION CONTROL MEASURES WILL BE MAINTAINED AT ALL TIMES. IF FULL IMPLEMENTATION OF THE APPROVED PLAN DOES NOT PROVIDE THE EFFECTIVE PRIOR TO, OR CONCURRENT WITH, LAND DISTURBING ACTIVITIES. 2. THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE PREVENTED BY THE INSTALLATION OF EROSION AND SEDIMENT CONTROL MEASURES AND PRACTICES 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. EROSION & SEDIMENT CONTROL PLAN - PHASE 3ES-320 1" = 40' 755 0 40'80'20'40' GRAPHIC SCALE:1" = 40' ZONE 20 30+0035+00 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 VAL 6060+13 EMT1 5954+92EMT1 6008+14SEE DRAWING NO. ES-324MATCH LINESEE DRAWING NO. ES-322MATCH LINESEE DRAWING NO. ES-337 MATCH LINE SEE DRAWING NO. ES-310 MATCH LINE PROP. WHEELED PARKING (TYP.) PROP. TRANSFER STAGING (TYP.) PROP. CONTAINER STACKING (TYP.)PROP. CONTAINER STACKING (TYP.) PROP. BARRIER WALL (TYP.)PROP. BARRIER WALL (TYP.) PROP. 30" STM. PROP. 48" STM. 3862-67-2716 CSX TRANSPORTATION, INC. 3863-71-6244 CSX TRANSPORTATION, INC. P/L PROP. PT02/ST06 TRACK PROP. PT03/ST07 TRACK PROP. CRANE RAIL 1 PROP. PT04 TRACK PROP. PT05 TRACK PROP. PT07 TRACK PROP. PT06 TRACK PROP. PT08 TRACK PROP. NORTH RIP TRACK PROP. CRANE RAIL 2 P/LPROP. 48" DUAL STM. CULVERT EX. STREAM BUFFER PROP. FIRE LINE (TYP.)PROP. FIRE LINE (TYP.) PROP. 12" UD PROP. 10" UD PROP. 12" UD PROP. 18" SD 55 52 49 46 RIM=128.67 RIM=127.78 RIM=127.33 PROP. 12" UD PROP. 10" UD PROP. 12" UD 65 62 59 56 RIM=127.33 RIM=127.78 RIM=128.67 RIM=128.90 PROP. 18" SD PROP. 18" SD PROP. 18" UD PROP. 12" UD PROP. 15" UD 25 24 23 22 RIM=127.33 RIM=127.78 RIM=128.67 RIM=128.90 PROP. 30" STM. PROP. 36" STM. PROP. 36" STM. PROP. 42" STM. 21RIM=122.09 PROP. 12" UD PROP. 12" UD PROP. 18" UD PROP. 18" SD HW3 INV=112.33 120 125 125 125 127 127128 128 129 129 129 129 128 127 127 127 127 127 128 128 127 127 125 125 125 127 127128 128 129 129 129 129 128 127 127 127 127 127 128 128 127 127 122 117 PROP. C/L DITCH PROP. C/L DITCH RIM=128.90 PROP. HML (TYP.) PROP. FH PROP. HML (TYP.)115113113116116ACCESS DRIVE PROP. GRAVEL PROP. GRAVEL ACCESS DRIVE 1201251 1 611611 7118119121122123124126116 RR RR RR RR PSRECP RECP PS RECP GRADING LIMITS (TYP.) PS ROCK CHANNEL PROTECTIONSTORMWATER OUTFALL 1201 1911811712112 2 121 12 2 GRADING LIMITS (TYP.) GRADING LIMITS (TYP.) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78304/12/201910:14:08 AMJ:\20180935\Dgn\04Sheets\13-Erosion Control Plan\ES-301-344.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING LEGEND PROPOSED BOLLARD EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER PROPOSED OVERHEAD ELECTRIC EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING EDGE OF GRAVEL EXISTING EDGE OF PAVEMENT/CURB EXISTING UTILITY PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT PROPOSED COMMUNICATION LINE XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED UNDERGROUND ELECTRIC PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN XX GL RR ROCK LINED DITCH VEGETATIVE DITCH LIMITS OF DISTURBANCE PS PERMANENT SEEDING RECP ROLLED EROSION CONTROL PRODUCT LIMITS OF GRADING FLOW ARROW STREAM/WETLAND PROTECTION FENCE ROCK CHANNEL PROTECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES SHALL CONTINUE THROUGH THE BENCH TO THE TOP OF THE SLOPE ABOVE THE BENCH. 6. GRASS-LINED DITCHES SHALL BE PROVIDED WITH EROSION CONTROL MATTING TO THE TOP OF DITCH SLOPE. WHERE BENCHING OCCURS, THE MATTING ALL SEEDED AREAS 3:1 AND STEEPER SHALL BE PROVIDED WITH EROSION CONTROL MATTING.5. MULCH. 4. ANY DISTURBED AREA LEFT EXPOSED AND IDOL FOR A PERIOD GREATER THAN 14 DAYS SHALL BE STABILIZED WITH MULCH OR TEMPORARY SEEDING WITH EROSION CONTROL, ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE IMPLEMENTED TO CONTROL OR TREAT THE SEDIMENT SOURCE. 3. EROSION CONTROL MEASURES WILL BE MAINTAINED AT ALL TIMES. IF FULL IMPLEMENTATION OF THE APPROVED PLAN DOES NOT PROVIDE THE EFFECTIVE PRIOR TO, OR CONCURRENT WITH, LAND DISTURBING ACTIVITIES. 2. THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE PREVENTED BY THE INSTALLATION OF EROSION AND SEDIMENT CONTROL MEASURES AND PRACTICES 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. EROSION & SEDIMENT CONTROL PLAN - PHASE 3ES-323 1" = 40' 758 0 40'80'20'40' GRAPHIC SCALE:1" = 40' ZONE 23 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 VAL 6060+13 EMT1 5954+92EMT1 6008+14SEE DRAWING NO. ES-327MATCH LINESEE DRAWING NO. ES-325MATCH LINESEE DRAWING NO. ES-340 MATCH LINE SEE DRAWING NO. ES-313 MATCH LINE TERMINAL DRIVE PROP. RETURN TO PROP. TERMINAL DRIVE PROP. TERMINAL DRIVE PROP. 12" STM. 3863-71-6244 CSX TRANSPORTATION, INC. EX. STREAM BUFFER LIMITS OF 500 YEAR FLOOD HAZARD EX. STREAM (TRM) EX. STREAM BUFFER EX. WETLAND (TRM) EX. STREAM BUFFER LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF 100 YEAR FLOOD HAZARD EX. WETLAND (TRM)EX. WETLAND (TRM) EX. WETLAND (TRM)EX. WETLAND (TRM) EX. STREAM BUFFER EX. STREAM (TRM) LIMITS OF 100 YEAR FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF 100 YEAR FLOOD HAZARD HW5 INV=92.04 PROP. 36" STM. CULVERT90 RIM=102.31 1 0 5 106 1 0 0 107 108 109 90 95 100 103 104 97 98 89 90 95 100 89 96 97 98 103 104 100101 10510510597106 106 1 0 5105108 110 109 109 108 1071071 0 4 1 0 310 310 01 0 4 1041031 0 3 108 108 PROP. C/L DITCH PROP. C/L DITCH PROP. C/L DITCH PROP. C/L DITCH PROP. C/L DITCH 105 109 1 0 3 1 0 2 1 0 2 105 107 108107 107108 109104RIM=98.07 88 PROP. 24" STM. PROP. LIGHT POLE (TYP.) 105 95 9596 97 9393 9997HW33 INV=96.93 PROP. LEVEL SPREADER (D) PROP. FENCE (TYP.) ARCHAEOLOGICAL SITE AREA 95100 96 9 7 9 8 99101102 95 95 100 10596 97 98 99 1011021031041061071089596979899100 101 100 97 98 99 95 1 0 0 105 90 90100 105 105104106107 107 9593 9395 9393 95 90 90 103 GL GL GL GL GL GL GL PS RECP RECP PS RECP RECP RECP RECP PS PS PS RECP PSRECP RECP PS PS RECP RECP RECP PS OUTFALL STORMWATER STORMWATER OUTFALL GRADING LIMITS (TYP.) PS PS PS PS PS POND 1POND 1 FENCE (TYP.) PROTECTIVE STREAM/WETLAND PROTECTION (TYP.) ROCK CHANNEL FENCE (TYP.) PROTECTIVE STREAM/WETLAND GRADING LIMITS (TYP.) FENCE (TYP.) PROTECTIVE STREAM/WETLAND with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78304/12/201910:14:09 AMJ:\20180935\Dgn\04Sheets\13-Erosion Control Plan\ES-301-344.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING LEGEND PROPOSED BOLLARD EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER PROPOSED OVERHEAD ELECTRIC EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING EDGE OF GRAVEL EXISTING EDGE OF PAVEMENT/CURB EXISTING UTILITY PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT PROPOSED COMMUNICATION LINE XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED UNDERGROUND ELECTRIC PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN XX GL RR ROCK LINED DITCH VEGETATIVE DITCH LIMITS OF DISTURBANCE PS PERMANENT SEEDING RECP ROLLED EROSION CONTROL PRODUCT LIMITS OF GRADING FLOW ARROW STREAM/WETLAND PROTECTION FENCE ROCK CHANNEL PROTECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES SHALL CONTINUE THROUGH THE BENCH TO THE TOP OF THE SLOPE ABOVE THE BENCH. 6. GRASS-LINED DITCHES SHALL BE PROVIDED WITH EROSION CONTROL MATTING TO THE TOP OF DITCH SLOPE. WHERE BENCHING OCCURS, THE MATTING ALL SEEDED AREAS 3:1 AND STEEPER SHALL BE PROVIDED WITH EROSION CONTROL MATTING.5. MULCH. 4. ANY DISTURBED AREA LEFT EXPOSED AND IDOL FOR A PERIOD GREATER THAN 14 DAYS SHALL BE STABILIZED WITH MULCH OR TEMPORARY SEEDING WITH EROSION CONTROL, ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE IMPLEMENTED TO CONTROL OR TREAT THE SEDIMENT SOURCE. 3. EROSION CONTROL MEASURES WILL BE MAINTAINED AT ALL TIMES. IF FULL IMPLEMENTATION OF THE APPROVED PLAN DOES NOT PROVIDE THE EFFECTIVE PRIOR TO, OR CONCURRENT WITH, LAND DISTURBING ACTIVITIES. 2. THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE PREVENTED BY THE INSTALLATION OF EROSION AND SEDIMENT CONTROL MEASURES AND PRACTICES 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. EROSION & SEDIMENT CONTROL PLAN - PHASE 3ES-326 1" = 40' 761 0 40'80'20'40' GRAPHIC SCALE:1" = 40' ZONE 26 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 VAL 6060+13 EMT1 5954+92EMT1 6008+14SEE DRAWING NO. ES-335MATCH LINESEE DRAWING NO. ES-320 MATCH LINE SEE DRAWING NO. ES-333MATCH LINE3862-56-2216 CSX TRANSPORTATION, INC. 3862-67-2716 CSX TRANSPORTATION, INC. 3862-67-2716 CSX TRANSPORTATION, INC. P/L P/L P/L EX. C/L DITCH (TRM) EX. 24" STM. (TRM) EX. C/L DITCH (TRM) EX. WETLAND (TRM) EX. STREAM BUFFER EX. STREAM (TRM) EX. WETLAND (TRM)EX. WETLAND (TRM) EX. STREAM BUFFER EX. STREAM (TRM) EX. STREAM BUFFER PROP. C/L DITCH 118118119PROP. FENCE (TYP.) P/LP/L PROP. FENCE (TYP.) EX. STREAM BUFFER EX. DITCH (TRM) 121 119 120119121121 122122 12312 3 1181 2 0 1161171181191 2 1 120 119118119 1201191 2 0120 125 125120 1251171181191211221231241 1 6 120 120 121 122123 124 119 118 117118 118117118119RR STREAM/WETLAND PROTECTIVE FENCE (TYP.) PROTECTIVE FENCE (TYP.) STREAM/WETLAND GRADING LIMITS (TYP.) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78304/12/201910:14:11 AMJ:\20180935\Dgn\04Sheets\13-Erosion Control Plan\ES-301-344.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING LEGEND PROPOSED BOLLARD EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER PROPOSED OVERHEAD ELECTRIC EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING EDGE OF GRAVEL EXISTING EDGE OF PAVEMENT/CURB EXISTING UTILITY PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT PROPOSED COMMUNICATION LINE XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED UNDERGROUND ELECTRIC PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN XX GL RR ROCK LINED DITCH VEGETATIVE DITCH LIMITS OF DISTURBANCE PS PERMANENT SEEDING RECP ROLLED EROSION CONTROL PRODUCT LIMITS OF GRADING FLOW ARROW STREAM/WETLAND PROTECTION FENCE ROCK CHANNEL PROTECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES SHALL CONTINUE THROUGH THE BENCH TO THE TOP OF THE SLOPE ABOVE THE BENCH. 6. GRASS-LINED DITCHES SHALL BE PROVIDED WITH EROSION CONTROL MATTING TO THE TOP OF DITCH SLOPE. WHERE BENCHING OCCURS, THE MATTING ALL SEEDED AREAS 3:1 AND STEEPER SHALL BE PROVIDED WITH EROSION CONTROL MATTING.5. MULCH. 4. ANY DISTURBED AREA LEFT EXPOSED AND IDOL FOR A PERIOD GREATER THAN 14 DAYS SHALL BE STABILIZED WITH MULCH OR TEMPORARY SEEDING WITH EROSION CONTROL, ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE IMPLEMENTED TO CONTROL OR TREAT THE SEDIMENT SOURCE. 3. EROSION CONTROL MEASURES WILL BE MAINTAINED AT ALL TIMES. IF FULL IMPLEMENTATION OF THE APPROVED PLAN DOES NOT PROVIDE THE EFFECTIVE PRIOR TO, OR CONCURRENT WITH, LAND DISTURBING ACTIVITIES. 2. THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE PREVENTED BY THE INSTALLATION OF EROSION AND SEDIMENT CONTROL MEASURES AND PRACTICES 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. EROSION & SEDIMENT CONTROL PLAN - PHASE 3ES-334 1" = 40' 769 0 40'80'20'40' GRAPHIC SCALE:1" = 40' ZONE 34 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 VAL 6060+13 EMT1 5954+92EMT1 6008+14SEE DRAWING NO. ES-338MATCH LINESEE DRAWING NO. ES-323 MATCH LINE SEE DRAWING NO. ES-336MATCH LINE3862-67-2716 CSX TRANSPORTATION, INC. 3863-71-6244 CSX TRANSPORTATION, INC. PROP. 24" STM.P/LEX. C/L DITCH (TRM)P/LPROP. 48" STM. EX. STREAM (TRM) EX. STREAM BUFFER EX. STREAM BUFFER INV=115.68 HW22 HW20INV=114.94 HW19 HW13 RIM=120.50 8 1 2 2 1 2 3 13 0 13 1 13 2 1 2 1 110 110 115 115 120 120 116 122 125 125 130 130 123 120123 125 125 130 130 123110116 122 110 110 115 115 131 132 107 PROP. MOUNDINGPROP. MOUNDING PROP. MOUNDINGPROP. MOUNDING PROP. 36" STM. HW12 INV=113.75 7 9 10 RIM=115.95 PROP. 24" STM. PROP. 12" STM. HW18 INV=112.91 INV=114.15 120115115RIM=118.00 INV=114.50 115 115 114 114 116RIM=119.00 122 121 115 116 110 110 115 116 120 120 120 121 120 120 116 115120120117115113115116113112112PROP. FENCE (TYP.) P/LP/L AND FILTER STRIP (C) PROP. LEVEL SPREADER FILTER STRIP (B) SPREADER AND PROP. LEVEL PROP. 36" STM. PROP. 18" STM. PROP. 36" STM. BUFFER EX. STREAM BUFFER EX. STREAM PROP. FENCE (TYP.)115120125 116117118119121122123124120 121 122 115116117118115116117118119115 120116 1171181191 2 1 122123124116 115114110115120 120 120 12 0 115115 1 1 0 115 115115 12 0 125120120 125 115 115 110RR PSRECP RECP PS RECP RECP RECP PS RECP RECP RECP PS RECP RECP RECP RECP PS PS PS RECP RECPPS RECPPS RECP STORMWATER OUTFALL STORMWATER OUTFALL STORMWATER OUTFALL GRADING LIMITS (TYP.) GRADING LIMITS (TYP.) GRADING LIMITS (TYP.) PS PS PS PS PS PS POND 3POND 3 POND 2POND 2 FOREBAY 2 ROCK CHANNEL PROTECTION (TYP.) FENCE (TYP.) STREAM/WETLAND PROTECTIVE STREAM/WETLAND PROTECTIVE FENCE (TYP.) PROTECTION (TYP.) ROCK CHANNEL GRADING LIMITS (TYP.)1191181 1 7 120 121 121 116121 12 2 12 3 12 4 125 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78304/12/201910:14:13 AMJ:\20180935\Dgn\04Sheets\13-Erosion Control Plan\ES-301-344.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING LEGEND PROPOSED BOLLARD EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER PROPOSED OVERHEAD ELECTRIC EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING EDGE OF GRAVEL EXISTING EDGE OF PAVEMENT/CURB EXISTING UTILITY PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT PROPOSED COMMUNICATION LINE XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED UNDERGROUND ELECTRIC PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN XX GL RR ROCK LINED DITCH VEGETATIVE DITCH LIMITS OF DISTURBANCE PS PERMANENT SEEDING RECP ROLLED EROSION CONTROL PRODUCT LIMITS OF GRADING FLOW ARROW STREAM/WETLAND PROTECTION FENCE ROCK CHANNEL PROTECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES SHALL CONTINUE THROUGH THE BENCH TO THE TOP OF THE SLOPE ABOVE THE BENCH. 6. GRASS-LINED DITCHES SHALL BE PROVIDED WITH EROSION CONTROL MATTING TO THE TOP OF DITCH SLOPE. WHERE BENCHING OCCURS, THE MATTING ALL SEEDED AREAS 3:1 AND STEEPER SHALL BE PROVIDED WITH EROSION CONTROL MATTING.5. MULCH. 4. ANY DISTURBED AREA LEFT EXPOSED AND IDOL FOR A PERIOD GREATER THAN 14 DAYS SHALL BE STABILIZED WITH MULCH OR TEMPORARY SEEDING WITH EROSION CONTROL, ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE IMPLEMENTED TO CONTROL OR TREAT THE SEDIMENT SOURCE. 3. EROSION CONTROL MEASURES WILL BE MAINTAINED AT ALL TIMES. IF FULL IMPLEMENTATION OF THE APPROVED PLAN DOES NOT PROVIDE THE EFFECTIVE PRIOR TO, OR CONCURRENT WITH, LAND DISTURBING ACTIVITIES. 2. THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE PREVENTED BY THE INSTALLATION OF EROSION AND SEDIMENT CONTROL MEASURES AND PRACTICES 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. EROSION & SEDIMENT CONTROL PLAN - PHASE 3ES-337 1" = 40' 772 0 40'80'20'40' GRAPHIC SCALE:1" = 40' ZONE 37 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78304/12/201910:15:00 AMJ:\20180935\Dgn\04Sheets\13-Erosion Control Plan\ES-401-404.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING EROSION & SEDIMENT CONTROL PLAN - DETAILSES-402 781 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 GRATE SEWER STORM CORNERS REINFORCED AREA CONTAINMENT 2 FOOT MANAGEABLE STRAPS LIFT STRAPS DUMPING INLET STORM CITY/STATE: PROJECT: DATE:DR. NO: DR. BY: DETAIL OF INLET SEDIMENT CONTROL DEVICE DANDY SACK TM Ô MONOFILAMENT FABRIC THAT MEETS OR EXCEEDS THE FOLLOWING SPECIFICATIONS: FROM A WOVENMANUFACTURED IN THE U.S.A. WILL BE NOTE: THE DANDY SACK Ô (BLACK)REGULAR FLOW DANDY SACK Ô SPECIFICATIONS DANDY SACK Mechanical Properties Test Method Units MARV Grab Tensile Strength ASTM D 4632 kN (lbs)1.78 (400) x 1.40 (315) Grab Tensile Elongation ASTM D 4632 15 x 15 Puncture Strength ASTM D 4833 kN (lbs)0.67 (150) Mullen Burst Strength ASTM D 3786 kPa (psi)5506 (800) Trapezoid Tear Strength ASTM D 4533 kN (lbs)0.67 (150) x 0.73 (165) UV Resistence ASTM D 4355 90 Apparent Opening Size ASTM D 4751 Mm (US Std Sieve)0.425 (40) Flow Rate ASTM D 4491 1/min/m (gal/min/ft )2852 (70) Permittivity ASTM D 4491 Sec 0.90-1 22 Ô (SAFETY ORANGE)HI-FLOW DANDY SACK Mechanical Properties Test Method Units MARV Grab Tensile Strength ASTM D 4632 kN (lbs)1.62 (365) X 0.89 (200) Grab Tensile Elongation ASTM D 4632 24 X 10 Puncture Strength ASTM D 4833 kN (lbs)0.40 (90) Mullen Burst Strength ASTM D 3786 kPa (psi)3097 (450) Trapezoid Tear Strength ASTM D 4533 kN (lbs)0.51 (115) X 0.33 (75) UV Resistence ASTM D 4355 90 Apparent Opening Size ASTM D 4751 Mm (US Std Sieve)0.425 (40) Flow Rate ASTM D 4491 1/min/m (gal/min/ft )5907 (145) Permittivity ASTM D 4491 Sec 2.1-1 22 Ô can be ordered with our optional oil absorbent pillows*Note: All Dandy Sacks PORTS OVERFLOW PROVIDE with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78304/12/201910:15:02 AMJ:\20180935\Dgn\04Sheets\13-Erosion Control Plan\ES-401-404.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING NOT TO SCALE INLET PROTECTION DETAIL NOT TO SCALE SEDIMENT BASIN DETAIL EROSION & SEDIMENT CONTROL PLAN - DETAILSES-404 783 115+00 118+81 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-102MATCH LINE6065+00 6070+00 PROP. SIDING TRACK (BY SEPARATE PLAN) 3862-31-1228 SUNSET PARTNERS LLC 3862-21-7187CSX TRANSPORTATION, INC. INV.(W)=89.92EX. END OF PIPE E X. P A V E ME NT E X. P A V E ME NT PROP. SWITCHING LEAD TRACK (BY SEPARATE PLAN) EX. C/L DITCH EX. MAINLINE TRACK 1 EX. MAINLINE TRACK 2 EX. FIBER OPTIC ELEC. EX. OVERHEAD P/L CSX R/W CSX R/W CSX R/W EX. PAVEMENT (TRM) EX. GRAVEL (TRM) (TYP.) EX. C/L DITCH P/L EX. POWER POLE EX. POW ER POLE CSX R/W CSX R/W EX. COMMUNICATION MARKEREX. 36" STM.INV.(E)=88.78EX. END OF PIPE EX. FENCE (TRM) EX. EDGE OF PAVEMENT (TRM) EX. 5' DRAINAGE & UTILITY EASEMENT P.B. 2. PAGE 151A EX. BOLLARD (TRM) EX. COMMUNICATION MARKEREASEMENT P.B. 2. PAGE 151A EX. 5' DRAINAGE & UTILITY CSX R/W TRACK 2EX. MAINLINE TRACK 1EX. MAINLINE EX. BUILDING EX. BUILDING EX. SIGN (TYP.) EX. FENCEEX. POWER POLE EX. NATURAL GAS LINE EX. BUILDING CSX R/W PROP. SIDING TRACK (BY SEPARATE PLAN) EX. WETLAND EX. FIBER OPTIC EX. WETLAND EX. STREAM 100 105 110 115 90 95 95929 3 94 9090 909 0 90 9592 9 2 92939495 9 0 90 9595 95 100 100 100 105 110 115 105110 95 95 100 105 105 100 95 100 95 95 9594 9090909090909090 112 113 114101 9899 97 9696 97 9898 908 9 9189 91 111 112 113 114 112113 1141 1 1 104 104 96 97 9 7 98100 105 110 102 9293 9 4 93 99100 101 102 102101 96 9293 9293 9491919292 96 9797 979693 8788 8988878788888787 88 89 89 8 9 8 9 9091 103 102 103 109 105 104 E X. P A V E ME NT E X. P A V E ME NT D.B. 1019. PAGE 637 EX. 30' POWER LINE EASEMENT DEVLOPMENT CORP P.B. 2. PAGE 151A EX. 60' EASEMENT FOR EDGECOMBE COUNTY with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:21 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 0 40'80'20'40' GRAPHIC SCALE:1" = 40' GRADING & DRAINAGE PLAN - ZONE 1CG-101 1" = 40' 197 115A VAL 6060+13105+00110+00 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-103MATCH LINESEE DRAWING NO. CG-101MATCH LINESEE DRAWING NO. CG-115 MATCH LINE 6055+00 6060+00 PROP. 36" STM. 3862-31-1228 SUNSET PARTNERS LLC 3862-32-8825 CSX TRANSPORTATION, INC. PROP. GRAVEL ACCESS DRIVE P/ L TRACK 2EX. MAINLINE TRACK 1EX. MAINLINE EX. MILE MARKER SIGN EX. FIBER OPTIC EX. SIGN EX. SIGN EX. ELEC. PULLBOX EX. ELEC. PULLBOX EX. COMM. MARKER CSX R/W EX. C/L DITCH (TRM) EX. FENCE EX. BUILDING(TYP.) EX. BUILDING (TYP.) EX. POWER POLE EX. EDGE OF PAVEMENT EX. FENCE (TYP.) EX. EDGE OF PAVEMENT EX. BUILDING (TYP.) EX. EDGE OF PAVEMENT EX. BUILDING (TYP.) EX. FENCE (TYP.)CSX R/W EX. POWER POLE EX. LIGHT POLE EX. EDGE OF PAVEMENT EX. BUILDING (TYP.) STR (TYP.)EX. WAT. EX. PAVEMENT CSX R/W CSX R/W P/ L (BY SEPARATE PLAN) PROP. SIDING TRACK PROP . C /L SOUTH LEAD TRACK EX. COMMUNICATION MARKER EX. 5' DRAINAGE & UTILITY EASEMENT P.B. 2. PAGE 151A CSX R/W PROP. SIDING TRACK (BY SEPARATE PLAN) EX. FIBER OPTIC EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 P RO P. 3 6" S TM. EX. STREAM EX. STREAM EX. W ETLAND (TRM) EX. WETLAND (TRM)EX. WETLAND (TRM) EX. STREAM (TRM) EX. STREAM BUFFER EX. STREAM BUFFER EX. STREAM (TRM) EX. WETLAND (TRM) EX. STREAM HW8 HW7 INV=96.22 INV=96.94 RIM=102.60 PROP. C/L DITCH P R O P. C/L DI T C H 100 100 102 96 105 10 2 1031 0 4 100 98 106 107 108951001051039899949910010410495 94 98 98 95 9510010598991051041051051071071051031039 8 1 0 0 1 0 4 1 0 4 1 0 0 9 9 9 8 9 5 95 95 95 100 100 105 105 10098 99101102100 105 101 102 103 104 106 107 1051101021031 0 4 1061071081091111121 0 096979 8 9 9 1 0 1 9999 96 9 5 9 5 100 10 5 105100 100100 100 100 105 10510510510 5105105 10 5 105 105 105 105 105 110 10595 100 94 95 95 100 9996 97 104 1 0 6 107 108 109 106107108109 9697 9697 99 98101 9798 99104 105 110 979 8 99101102103105 104 109 110 105 105106 105 104(PROJECT DEMARCATION POINT) PROP. NO. 10 LH T/O HW10 RIM =103.33113 P R O P. C/L DI T C H PROP. LIGHT POLE PROP. GRAVEL ACCESS DRIVE PROP. FENCE (TYP.) 9 5 P RO P. 4 2 " S TM. 2 3 IN V =97. 5 0PROP. STORMWATER MANAGEMENT BASIN PROP. AT-GRADE RAIL CROSSING P.B. 2. PAGE 151A DEVLOPMENT CORP EDGECOMBE COUNTY EX. 60' EASEMENT FOR PAGE 637 EASEMENT D.B. 1019. EX. 30' POWER LINE P.B. 2. PAGE 151A DEVLOPMENT CORP EDGECOMBE COUNTY EX. 60' EASEMENT FOR 10510510699 100 102 98 95 95 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:23 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 2CG-102 1" = 40' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' 198 100+00JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-104MATCH LINESEE DRAWING NO. CG-102MATCH LINESEE DRAWING NO. CG-116 MATCH LINE 6045+00 6050+00 PRO P. S T 0 7 TR AC K PRO P. S T 0 6 TR AC K PROP. ORNAMENTAL FENCE (TYP.) PROP. GRAVEL ACCESS DRIVE PROP. ACCESS DRIVE TURNAROUND 3862-32-8825 CSX TRANSPORTATION, INC. EXISTING CEMETERY (TRM) EX . C /L D ITCH (TRM )EX. MAINLINE TRACK 1 EX. MAINLINE TRACK 2 EX. FIBER OPTIC CSX R/W CSX R/W EX. C/L DITCH (TRM) EX. DIRT ROAD (TRM) (TYP.) CSX R/W LE A D T R A C K P R O P. C/L S O U T H PROP. SIDING TRACK (BY SEPARATE PLAN) PROP. SIDING TRACK (BY SEPARATE PLAN) EX. FIBER OPTIC EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 EX. STREAM EX. WETLAND (TRM) EX . WETLAND (TRM )110 109 1 1 01101111 0 8108 115 1 1 0108 1 1 3 1 0 8 1 06106 108106106109110 115 120 125 1291 0 9105 110 108 109 111 115120125112113114116117118119121122123124126127128129105 1 0 5 105 110 110 110 110 110 110 105 110 115 120118119121120 110 110120120 115 115 115 1221101 0 9 115120125123 124126125126127 1 2 2 122 123 124 110 111 112 113114 115 115 115 105 1101 0 6 107 10 5105 105128 11 1 1 1 2 1131 1 4 116 117118119121 128 111 P R O P. C/L DI T C H P R O P. C/L DI T C H P R O P. LIG H T P O LE PROP . GRAVE L ACCESS DR IVE PROP . GRAVEL ACCESS DR IVE EX. DIRT ROAD (TRM) EX. DIRT ROAD (TRM) (TYP.) PROP. FENCE (TYP.) PROP. FENCE (TYP.) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:24 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 3CG-103 1" = 40' 199 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-105MATCH LINESEE DRAWING NO. CG-103MATCH LINESEE DRAWING NO. CG-117 MATCH LINE 6040+00 PROP. ORNAMENTAL FENCE (TYP.) PROP. GATE 3862-32-8825 CSX TRANSPORTATION, INC. 3862-44-2350 CSX TRANSPORTATION, INC. 3862-44-2350 CSX TRANSPORTATION, INC. 3862-43-5381 CSX TRANSPORTATION, INC. PROP. FENCE (TYP.) EX. MAINLINE TRACK 1 EX. MAINLINE TRACK 2 EX. FIBER OPTIC CSX R/W EXISTING CEMETERY (TRM)EXISTING CEMETERY (TRM)P/ L P/ L CSX R/W EX. ELEC. PULLBOX P/ L PROP. GRAVEL ACCESS DRIVE PROP. GRAVEL ACCESS DRIVE PROP. SIDING TRACK (BY SEPARATE PLAN) PROP. SIDING TRACK (BY SEPARATE PLAN) EX. FIBER OPTIC EX. MAINLINE TRACK 2 PROP. WAT. (TYP.) 120 125 129 125 127 117 128 128129129129 127127128 128129 125125 125 125115 115 115 125 125 120 120 125 120120 120 125 116 120 117 118 119 121 122 126127127128 128 125 126 127 126126 128 127128128 120 120 130 128 128 1281 2 8 128127126 126127PROP. ADDITIONAL STOCKPILE AREAPROP. ADDITIONAL STOCKPILE AREA 128125 128 129 EX. DIRT ROAD (TRM) EX. DIRT ROAD (TRM) INV=118.02 PROP. FENCE (TYP.) PROP. FENCE (TYP.) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:25 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 4CG-104 1" = 40' 200 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-106MATCH LINESEE DRAWING NO. CG-104MATCH LINESEE DRAWING NO. CG-118 MATCH LINE 6025+00 6030+00 PROP. GATE FENCE (TYP.) PROP. ORNAMENTAL PROP. GATE PROP. TURNAROUND 3862-44-2350 CSX TRANSPORTATION, INC. 3862-44-3619 CSX TRANSPORTATION, INC. 3862-55-2186 CSX TRANSPORTATION, INC. 3862-45-2503 BAPTIST CHURCH MARKS CHAPEL 3862-45-5921 CSX TRANSPORTATION, INC. PROP. FENCE (TYP.) POLE (TRM) EX. POWER P/ L EX. ELEC. PULLBOX EX. SHED INV.(N)=121.00 EX. END OF PIPE EX. 12" STM. INV.(S)=119.77 EX. END OF PIPE EX. MAINLINE TRACK 2 EX. FIBER OPTIC CSX R/W EX. MAINLINE TRACK 1 P/ L P/ L P/ L EX. COMMUNICATION MARKER EX. SIGN CSX R/W (TRM) CEMETERY EXISTING (TRM) CEMETERY EXISTING P/ L EX. GRAVEL (TRM) PROP. GRAVEL ACCESS DRIVE PROP. GRAVEL ACCESS DRIVE PROP. SIDING TRACK (BY SEPARATE PLAN) P/ L P/L EX. FIBER OPTIC PROP. SIDING TRACK (BY SEPARATE PLAN) EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 PROP. WAT. (TYP.) 125 127 122 1 2 7127 12 7 127127 1271 2 7 12 7 126 1 2 7 1 2 8 127 125 125 125 125 125 125 125 125 125 12712712 7 PROP. ADDITIONAL STOCKPILE AREAPROP. ADDITIONAL STOCKPILE AREA 128 125126 125123 EX. GRAVEL (TRM) P/ L PROP. FENCE (TYP.) PROP. FENCE (TYP.) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:26 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 5CG-105 1" = 40' 201 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-107MATCH LINESEE DRAWING NO. CG-105MATCH LINESEE DRAWING NO. CG-119 MATCH LINE 6015+00 6020+00 PROP. ORNAMENTAL FENCE (TYP.)PROP. GATE PROP. GATE FENCE (TYP.) PROP. ORNAMENTAL PROP. GATE3862-45-2503 MARKS CHAPEL BAPTIST CHURCH 3862-45-5921 CSX TRANSPORTATION, INC. 3862-56-2216 CSX TRANSPORTATION, INC. EXISTING CEMETERY (TRM)EXISTING CEMETERY (TRM) CSX R/W EX. COMMUNICATION MARKER EX. MAINLINE TRACK 1 EX. MAINLINE TRACK 2 EX. FIBER OPTIC EX. GRAVEL (TRM) P/ L P/L EX. GRAVEL CSX R/W PROP. GRAVEL ACCESS DRIVE ACCESS DRIVE PROP. GRAVEL PROP. SIDING TRACK (BY SEPARATE PLAN) P/ L P/L P/ L EX. FIBER OPTIC PROP. SIDING TRACK (BY SEPARATE PLAN) EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 P/L EX. COMM. MARKER (TRM) EX. FENCE (TRM) PROP. WAT. (TYP.) 13 0 130 130 130 130 130130 1 3 0 130 130 130 130 130 130 130 130 1261261261261 2 7 128 128 1 2 9 127126127 127126127 125126 127 128 126127 127 128 126 126 125 1271 2 7 128 129 125 12 7 127 128 128127126 PROP. ORNAMENTAL FENCE (TYP.) 125 PROP. C/L DITCH EX. GRAVEL (TRM) EX. C/L DITCH (TRM) EX. C/L DITCH (TRM) EX. C/L DITCH (TRM) P/L P/L PROP. GATE 128 125 125 129 123 125125126 126 129 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:27 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 6CG-106 1" = 40' 202 0 40'80'20'40' GRAPHIC SCALE:1" = 40' ++++EMT1 6008+14114 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-108MATCH LINESEE DRAWING NO. CG-106MATCH LINESEE DRAWING NO. CG-120 MATCH LINE 6005+00 6010+00 FENCE (TYP.)PROP. ORNAMENTAL PROP. GATEPROP. GATE3862-56-2216 CSX TRANSPORTATION, INC.COLLEGE RDEX. 16" WAT. LINE (TRM) (PLAN)EX. C/L DITCH (TRM) (TYP.)EX. COMM. MARKER (TRM)EX. POWER POLE (TRM) EX. POWER POLE EX. POWER POLE (TRM) EX. POWER POLE (TRM) EX. OVERHEAD ELEC. (TRM) EX. C/L DITCH (TRM) (TYP.) EX. OVERHEAD ELEC. (TRM) EX. SIGN (TRM) EX. 36" STM. INV.(W)=122.80 EX. END OF PIPE EX. COMMUNICATION MARKEREX. MILE MARKER SIGN (TRM) CULVERT EX. 12" STM. MH (TRM) EX. ELEC. EX. ASPHALT PAVEMENT (TRM) EX. GUY WIRE (TRM)P/LEX. COMM. PEDESTAL (TRM) (TYP.) EX. COMM. MARKER (TRM) EX. POWER POLE (TRM) EX. OVERHEAD ELEC. (TRM) EX. STM. CULVERT (TRM) EX. C/L DITCH (TRM) (TYP.) (TRM) (PLAN) EX. 16" WAT. LINE (TRM) CULVERT EX. STM. EX. GUY WIRE (TRM) EX. POWER POLE (TRM) WIRE (TRM) EX. GUY R/WR/WCSX R/W CSX R/W R/WR/WEX. COMMUNICATION MARKER EX. SHED EX. FIBER OPTIC EX. CROSSING SIGNAL EX. ELEC. SIGNAL EX. CROSSING EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 CSX R/W CSX R/W PROP. ACCESS DRIVE PROP. SIDING TRACK (BY SEPARATE PLAN) INV.(W)=122.99 EX. END OF PIPE EX. 16" DFV W/ BOX (TRM) (PLAN) EX. 30" WAT. LINE ENCASEMENT (PLAN) EX. 60' RIGHT OF WAY (TRM) PROP. SIDING TRACK (BY SEPARATE PLAN) EX. FIBER OPTIC EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 P/L EX. FENCE (TRM) (TRM) BOLLARD EX. EX. C/L DITCH EX. WETLAND (TRM) PROP. FH PROP. WAT. (TYP.) HW2 INV=118.86 125 130 130 130 130 130 130 130 130 130 130 130130 130 125 125 125125 125125 125 12312312 4124 1261271221 2 8 130 130130130 130130 126127 125125125121122123124126127125121122123124126120128127126128127126125 124126 12512 5 125125127 12 8128128 PROP. FENCE (TYP.) PROP. ADDITIONAL STOCKPILE AREAPROP. ADDITIONAL STOCKPILE AREA 125 127 127 PROP. C/L DITCH PROP. C/L DITCH PROP. C/L DITCH 123 EX. C/L DITCH (TRM) UTILIZED (BY SEPARATE PLAN) APPROXIMATE STOCKPILE AREA UTILIZED (BY SEPARATE PLAN) APPROXIMATE STOCKPILE AREA TOWER FUT. COMMUNICATION PROP. FENCE (TYP.) PROP. 48" STM. CULVERT 122 125 127 124 125122 124 123 122 125 120 120 125 125126 121 126 12 6 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:28 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 7CG-107 1" = 40' 203 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-109MATCH LINESEE DRAWING NO. CG-107MATCH LINESEE DRAWING NO. CG-121 MATCH LINE 5995+00 6000+00 3862-56-2216 CSX TRANSPORTATION, INC. 3862-67-2716 CSX TRANSPORTATION, INC. CSX R/W CSX R/W EX. FIBER OPTIC EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 EX. COMMUNICATION MARKER EX. MILE MARKER SIGN EX. MILE MARKER SIGN CSX R/W CSX R/W EX. OVERHEAD ELEC. EX. POWER POLE EX. C/L DITCH EX. FIBER OPTIC EX. COMMUNICATION MARKER P/ LP/ L PROP. SIDING TRACK (BY SEPARATE PLAN) EX. MAINLINE TRACK 1 PROP. SIDING TRACK (BY SEPARATE PLAN) EX. MAINLINE TRACK 2 123 130 130 130 130 130 130130 130 1 3 0 130 130130 130 130 125125 12 6 1 2 61 2 6 12 7 124 12 51271281 2 7 12 8 129 128 127 127 PROP. ADDITIONAL STOCKPILE AREAPROP. ADDITIONAL STOCKPILE AREA 125 PROP. C/L DITCH UTILIZED (BY SEPARATE PLAN) APPROXIMATE STOCKPILE AREA UTILIZED (BY SEPARATE PLAN) APPROXIMATE STOCKPILE AREA PROP. FENCE (TYP.) 125 125126 126 125 125 126 126 124 122 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:30 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 8CG-108 1" = 40' 204 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-110MATCH LINESEE DRAWING NO. CG-108MATCH LINESEE DRAWING NO. CG-122 MATCH LINE 5990+00 5995+00 3862-67-2716 CSX TRANSPORTATION, INC. 3863-71-6244 CSX TRANSPORTATION, INC. EX. 36" STM. INV.(W)=119.20 EX. END OF PIPE PROP. NORTH RIP TRACK EX. OVERHEAD ELEC. EX. C/L DITCH CSX R/W EX. FIBER OPTIC EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 CSX R/W EX. C/L DITCH EX. COMMUNICATION MARKER CSX R/W CSX R/W EX. MAINLINE TRACK 2 EX. FIBER OPTIC P/LP/ L (BY SEPARATE PLAN) PROP. SIDING TRACK PROP. SIDING TRACK (BY SEPARATE PLAN) EX. OVERHEAD ELEC. EX. C/L DITCH EX. OVERHEAD ELEC. EX. COMMUNICATION MARKER EX. STREAM EX. ENDWALL INV.(E)=BURIED EX. END OF PIPE EX. C/L DITCH TRACK 1 EX. MAINLINE EX. STREAM BUFFER EX. STREAM (TRM) EX. STREAM BUFFER EX. WETLAND (TRM) POLE POWER EX. 122 127 130 130 130130 130 130 125 130 130 125 125125 125 125 125125 130 130 128 129 127 125 123123 124124126127 127 128 125121122123124126127127 127125PROP. C/L DITCH PROP. ADDITIONAL STOCKPILE AREAPROP. ADDITIONAL STOCKPILE AREA 125124123 123 125 126 124 PROP. C/L DITCH PROP. GRAVEL ACCESS DRIVE 125 125 127 123 125 120 120 125 119 118 123 124 125 EX. C/L DITCH (TRM) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:31 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 9CG-109 1" = 40' 205 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-111MATCH LINESEE DRAWING NO. CG-109MATCH LINESEE DRAWING NO. CG-123 MATCH LINE 5980+00 5985+00 3863-71-6244 CSX TRANSPORTATION, INC. EX. 24" STM.EX. 24" STM. INV.(E)=120.07 EX. END OF PIPEFILLED WITH DEBRIS INV.(W)=122.60 EX. END OF PIPE FILLED WITH DEBRIS INV.(W)=120.56 EX. END OF PIPE INV.(W)=119.70 EX. END OF PIPE 3862-67-2716 CSX TRANSPORTATION, INC. CSX R/W CSX R/W EX. FIBER OPTIC EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 EX. C/L DITCH EX. COMMUNICATION MARKER EX. WOODEN BRIDGE EX. COMMUNICATION MARKER EX. PAVEMENT EX. FH EX. WAT. LINE EX. GUY WIRE EX. POWER POLE EX. OVERHEAD ELEC. EX. OVERHEAD ELEC. POLE EX. POWER CSX R/W CSX R/W P/L PROP. 48" DUAL STM. CULVERT (BY SEPARATE PLAN) PROP. SIDING TRACK PROP. NORTH RIP TRACK EX. GUY WIRE EX. POWER POLE EX. OVERHEAD ELEC. EX. OVERHEAD ELEC. PROP. SIDING TRACK (BY SEPARATE PLAN) EX. FIBER OPTIC EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 EX. OVERHEAD ELEC. EX. WETLAND (TRM) EX. STREAM BUFFER EX. STREAM BUFFER EX. STREAM (TRM) EX. STREAM HW4 EX. POWER POLE 124 125 130 135 138 138 123125130135137130 130 130130 125125 125 125 125125125 125 126 127 128 129 126127128125123 124126127 1 2 5123124 1261 2 7 1251251 2 1 12312312412412612 6 1251221231241261 2 7 127 12 7 1 2 1 1 2 0 122120120 12 2 12212012012112 7 12 6 12 6 PROP. C/L DITCH PROP. C/L DITCH PROP. STOCKPILE AREAPROP. STOCKPILE AREA HW21 INV=119.27 126125 125 126 125 123 126 126 PROP. C/L DITCH PROP. C/L DITCH PROP. C/L DITCH EX. GRAVEL (TRM) PROP. GRAVEL ACCESS DRIVE INV=113.89120 120 125 127 126 125 124 123 122 121 120 125 115 115 135 130 120 125 127 125 127 1 2 2 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:32 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 10CG-110 1" = 40' 206 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-112MATCH LINESEE DRAWING NO. CG-110MATCH LINESEE DRAWING NO. CG-124 MATCH LINE 5970+00 5975+00 PROP. ST07 TRACK PROP. NORTH RIP TRACK ACCESS DRIVEPROP. GRAVEL PROP. 10" UD 3863-71-6244 CSX TRANSPORTATION, INC. EX. 8" STM. INV.(W)=122.65 EX. END OF PIPE INV.(W)=122.08 EX. END OF PIPE BFV (PLAN) EX. 24" ASPHALT PAVEMENT EX. EDGE OF EX. POWER POLE EX. FENCE (TYP.) PROP. NORTH RIP TRACK EX. POWER POLE EX. OVERHEAD ELEC. EX. OVERHEAD ELEC. CSX R/W EX. MAINLINE TRACK 1 EX. MAINLINE TRACK 2 EX. FIBER OPTIC CSX R/W EX. PAVEMENT EX. 8" WAT. LINE (PLAN)EX. CURB & GUTTER EX. POWER POLE EX. 24" WAT. MAIN (PLAN) EX. SIGN EX. WAT. MARKER EX. 24" WAT. MAIN (PLAN) CSX R/W EX. CONCRETE PAVEMENT ELEC. EX. OVERHEAD EX. OVERHEAD ELEC. EX. EDGE OF ASPHALT PAVEMENT CSX R/W EX. 30" WAT. MAIN ENCASEMENT (PLAN) EX. WAT. MARKER EX. 40' WATER EASEMENT (PLAN) EX. BUILDING EX. FIBER OPTIC PROP. SIDING TRACK (BY SEPARATE PLAN) EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 PROP. PT04 TRACK PROP. SIDING TRACK (BY SEPARATE PLAN) PROP. WAT. (TYP.) POLE POWER EX. PROP. 24" STM. PROP. 24" STM. PROP. 10" UD HW23 INV=119.37 125126 123 123 120 120 125 122 127 125 122 123 124 1 2 6 118118 120 117 130 135 128 138 138 130 130 135 135 128 138 137 128 130135 128129131132133134136137 120125122 130 130 130130130 1301 2 5 125 125 125 125 125 125 125 125 120 127127127 125 126 127 128 125 125 125 130 120125 1 1 8 121 1221231241 2 6 12012511811 91211221231241261271271171161 2 7 12 5 12 5 12 6 127 1 1 9 PROP. C/L DITCH PROP. STOCKPILE AREAPROP. STOCKPILE AREA PROP. C/L DITCH 125 PROP. C/L DITCH PROP. GRAVEL ACCESS DRIVE 135 130 125 125 127 127 120 126 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:33 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 11CG-111 1" = 40' 207 0 40'80'20'40' GRAPHIC SCALE:1" = 40' 10+00 15+00 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-113MATCH LINESEE DRAWING NO. CG-111MATCH LINESEE DRAWING NO. CG-125 MATCH LINE 5960+00 5965+00 PROP. ST07 TRACK PROP. PT08 TRACK PROP. NORTH RIP TRACK PROP. NORTH LEAD TRACK PROP. GRAVEL ACCESS DRIVE PROP. 10" UD PROP. 18" STM. PROP. 36" STM. 3863-71-6244 CSX TRANSPORTATION, INC. CSX R/W EX. MAINLINE TRACK 1 EX. MAINLINE TRACK 2 EX. FIBER OPTIC EX. FENCE (TYP.) EX. EDGE OF ASPHALT PAVEMENT CSX R/W EX. CONCRETE PAVEMENT EX. POWER POLE EX. POWER POLE EX. EDGE OF CONCRETE PAVEMENT EX. OVERHEAD ELEC. EX. OVERHEAD ELEC. EX. POWER POLE EX. BOLLARD EX. BOLLARD ELEC. EX. OVERHEAD EX. OVERHEAD ELEC. EX. EDGE OF ASPHALT PAVEMENT EX. EDGE OF ASPHALT PAVEMENT EX. FENCE (TYP.) EX. POWER POLE EX. COMMUNICATION MARKER CSX R/W CSX R/W EX. OVERHEAD ELEC. RAIL CROSSINGPROP. AT-GRADE EX. OVERHEAD ELEC. EX. POWER POLE (BY SEPARATE PLAN) PROP. SIDING TRACK PROP. SIDING TRACK (BY SEPARATE PLAN) EX. FIBER OPTIC EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 EX. OVERHEAD ELEC.EX. POWER POLE PROP. NORTH ENGINE READY TRACK EX. WETLAND (TRM)EX. WETLAND (TRM) PROP. SAN. (TYP.) 77 RIM=119.67 HW24INV=116.34 PROP. GRAVEL ACCESS DRIVE RIM=115.39 INV=109.86 HW25 120 116 117 118 119 121 120 118 119 110 110110 115 108 120 120 120 116 115115 117 115116 114 112112 117 117 117116 115 115 106 110 118120117 110115120 110 120 120 120 115 120 115 1 1 5 115 115 120125 120 120 120 120 120 120 116 1 1 7 118 119 121 120 116 117 118 119 121 122 123 115 116 105 110 101102 103 104 106 107 108 109 111 112 113 114 115 116 117 115 113114 116 110 111 112 115 114116 117118 105105104106 104 110 106107108109111105115111 112 1131 1 4 1 1 6 110 115 106 107 108 109 111 112 113 114 120 124121 122 120 116PROP. C/L DITCH PROP. C/L DITCH PROP. STOCKPILE AREA 116 117 121 122 122 118 118 115 111 111 109 110 106 113 106 78 PROP. GRAVEL ACCESS DRIVE PROP. WAT. (TYP.) 115 115 115116 HW28 INV=110.67 120 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:34 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 12CG-112 1" = 40' 208 0 40'80'20'40' GRAPHIC SCALE:1" = 40' + + + + + 113 A EMT1 5954+920+00 5+00 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-114MATCH LINESEE DRAWING NO. CG-112MATCH LINESEE DRAWING NO. CG-126 MATCH LINE 5950+00 5955+00 PROP. NORTH LEAD TRACK PROP. SIDING TRACK (BY SEPARATE PLAN) PROP. GRAVEL ACCESS DRIVE 3863-71-6244 CSX TRANSPORTATION, INC. EX. POWER POLE EX. SAN. STEEL ENCASEMENT INV.(E)=92.11 EX. END OF CGLVERT INV.(E)=87.69 EX. END OF PIPE EX1 EX. MAINLINE TRACK 1 EX. MAINLINE TRACK 2 EX. FIBER OPTIC CSX R/W CSX R/W EX. POWER POLE EX. OVERHEAD ELEC. EX. POWER POLE EX. OVERHEAD ELEC. EX. OVERHEAD ELEC.EX. OVERHEAD ELEC. EX. POWER POLEEX. GUY WIRE EX. GUY WIRE EX. POWER POLE EX. 27" SAN. (PLAN) EX. 4.7' X 12' STM. BOX CULVERT CSX R/W EX. PAVEMENT EX. OVERHEAD ELEC. EX. OVERHEAD ELEC. INV.(W)=90.38 EX. END OF CULVERT EX. 12" STM. INV.(W)=86.73 EX. END OF PIPE CSX R/W EX . 2 7 " SAN . (TRM ) (P LAN )INV.(W)=81.63 (PLAN) INV.(E)=81.58 (PLAN) RIM=95.16 (FV) EX. SAN. MH (TRM) E X. 27" S A N. (T RM) ( PL A N) INV.(NW)=80.49 27" RCP INV.(NE)=80.36 27" RCP RIM=95.01 EX. SAN. MH (TRM) (FV) (PLAN) EX. 30" SAN. INV.(W)=80.80 30" RCP INV.(E)=80.71 30" RCP RIM=95.35 EX. SAN. MH (FV) EX. OVERHEAD ELEC. EX. BOLLARD EX. C/L DITCH EX. C/L DITCH EX. FIBER OPTIC (BY SEPARATE PLAN) PROP. PS NO. 15 LH T/O EX. POWER POLE EX. MILE MARKER SIGN EX. STREAM EX. OVERHEAD ELEC. PROP. SIDING TRACK (BY SEPARATE PLAN) EX. WETLAND (TRM)EX. WETLAND (TRM) LIMITS OF 100 YEAR FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD EX. WETLAND (TRM)EX. WETLAND (TRM) EX. WETLAND (TRM) LIMITS OF FLOOD HAZARD EX. WETLAND (TRM) EX. STREAM BUFFER EX. STREAM (TRM) EASEMENT (PLAN) EX. 30' PERMANENT LIMITS OF FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD FLOOD HAZARD LIMITS OF 100 YEAR LIMITS OF FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD FLOOD HAZARD LIMITS OF 100 YEAR EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 LIMITS OF 100 YEAR FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD EX. FIBER OPTIC EX. STREAM BUFFER EX. WETLAND (TRM)EX. WETLAND (TRM) LIMITS OF 100 YEAR FLOOD HAZARD PROP. SAN. (TYP.) 115 114 114 112112 110 1151 1 5 115115 115 115 105 110 115 101 102 103 104 106 107 108 109 111 111 111 112 113 114 116 100 100 105 110 98 99 101 102 103 104 106 107 108 109 110 110 100105110959090 90 90 90 90 90 909595 95 95115 115 115 10510510095 909090 90 95 100 919292 9293 94 96 97 98 99 90 91 90 9595 90 90 9 5 PROP. C/L DITCH 114115 (PS DERAIL) PROJECT DEMARCATION POINT HW27 INV=105.15 91 RIM=112.97 PROP. 36" STM. PROP. 36" STM. 110 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:35 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 13CG-113 1" = 40' 209 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 ASEE DRAWING NO. CG-113MATCH LINESEE DRAWING NO. CG-127 MATCH LINE 5940+00 5945+00 3863-71-6244 CSX TRANSPORTATION, INC. EX. BUILDING CSX R/W CSX R/W ELEC. OVERHEAD EX. BOLLARD EX. EX. BOLLARD EX. CONCRETE PAVEMENT EX. FENCE (TYP.) EX. POWER POLE EX. PAVEMENT PAVEMENT EX. CONCRETE EX. STM. (TYP.) EX. PAVEMENT EX. OVERHEAD ELEC. EX. OVERHEAD ELEC. EX. POWER POLE EX. OVERHEAD ELEC. EX. EDGE OF PAVEMENT EX. LIGHT POLE EX. POWER POLE EX. STM. (TYP.) EX. OVERHEAD ELEC. EX. FENCE (TYP.) CSX R/W EX. 27" SA N. (T R M) (PLA N)INV.(W)=81.32 (PLAN) INV.(E)=81.25 (PLAN) RIM=93.61 (FV) EX. SAN. MH (TRM) EX . 2 7 " SAN . (TRM ) (P LAN )CSX R/W PROP. SIDING TRACK (BY SEPARATE PLAN) EX. FIBER OPTIC EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 EX. POWER POLE EX. OVERHEAD ELEC. PROP. SIDING TRACK (BY SEPARATE PLAN) EX. FIBER OPTIC EX. MAINLINE TRACK 2 EX. MAINLINE TRACK 1 FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF 100 YEAR EX. GUY WIRE (TYP.) EX. OVERHEAD ELEC. EX. POWER POLE EX. WETLAND (TRM) LIMITS OF 100 YEAR FLOOD HAZARD EX. STREAM BUFFER LIMITS OF FLOOD HAZARD EX. STREAM BUFFER EX. STREAM BUFFER EX. WETLAND (TRM)EX. WETLAND (TRM) EX . 3 0' PERMANENT EASEMEN T (P LAN )EX. STREAM (TRM) EX. STREAM (TRM) LIMITS OF 500 YEAR FLOOD HAZARD EX. STREAM BUFFER LIMITS OF 100 YEAR FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF 100 YEAR FLOOD HAZARD1001051 0 0 100100 100 100 105 110110110110110 95 100 105 90 9 5 100 105 899 1 92939 4 9 6 9 7 9 8 99 10110210310 4106 100105 101102103104 10099 101102 1031041051 0 5 106 107 9095 100 919293 94 96 97 98 99 101 908 9 90 90 90909090909090 90 9 0 90 90909095 91 92 93 94 105104 106 1 0 7 107 1 0 0 105105105110110115115 120116117118119 115 113113113 114 116117118119 110 110 110 105 110105 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:37 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 08, GL-09 AND GL-10. (SEE DRAWING NO. CS-201 TO CS-204). ARRANGEMENT PER CSXIT STANDARD DETAILS GL-01, GL-07, GL- 7. PORTALS AND GATE AREA BOLLARD PROTECTION AND EQUPMENT ALL BOLLARDS ARE 10" DIAMETER UNLESS OTHERWISE NOTED.6. INSTALLATION REQUIREMENTS. ELECTRICAL PLANS, FOR ACTUAL LOCATION, SIZE AND PLAN SETION IS FOR REFERENCE ONLY. REFER TO APPENDIX D, ELECTRIC AND COMMUNICATION LINEWORK SHOWN WITHIN THIS 5. LINE INSTALLATION AND MATERIAL INFORMATION. 4. SEE APPENDIX B AND C, WATER RELOCATION PLAN, FOR WATER INSTALLATION AND MATERIAL INFORMATION. 3. SEE APPENDIX A, SANITARY SEWER PLAN, FOR SANITARY SEWER 2. SEE DRAWING NO. CU-201 TO CU-205 FOR UTILITY DETAILS. T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 14CG-114 1" = 40' 210 0 40'80'20'40' GRAPHIC SCALE:1" = 40'NO WORK THIS SHEET JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-116MATCH LINESEE DRAWING NO. CG-129 MATCH LINE SEE DRAWING NO. CG-102 MATCH LINE PROP. 1 2" S T M. 3862-31-1228 SUNSET PARTNERS LLC 3862-31-8523 ROCKY MOUNT/EDGECOMBE COMM DEV 3862-32-8825 CSX TRANSPORTATION, INC. E X. P A V E ME NT ( T RM) E X. P A V E ME NT ( T RM) EX. BUILDING (TRM)EX. BUILDING (TRM) EX. SIGN (TRM) P/ L EX. POWER POLE (TRM) EX. OVERHEAD ELEC. (TRM) EX. LIGHT POLE (TRM) E X. LI GHT P OL E ( T RM) E X. P OWE R P OL E ( T RM) EX. SIGN (TRM) (TYP.) E X. C/ L DI T CH ( T RM) E X. LI GHT P OL E ( T RM) E X. OV E RHE A D E L E C. ( T RM) E X. P OWE R P OL E ( T RM)E L E C. ( T RM) E X. OV E RHE A DP/ L (TRM) (TYP.) EX. DIRT ROAD P/L EX. OVERHEAD ELEC. (TRM) EX. OVERHEAD ELEC. (TRM) EX. STREAM BUFFER EX. STREAM (TRM) EX. WETLAND (TRM) EX. STREAM BUFFER EX. STREAM BUFFER EX. WETLAND (TRM) EX. STREAM (TRM) EX. STREAM BUFFER EX. STREAM BUFFER 1 HW9 RI M= 1 0 1. 5 0 I NV = 9 8. 4 6 9 5 1 0 0 1 0 0 9 8 1 0 4 1 0 4 9 8 95 100 105 110 98 99 104 1 0 0 100105105110 110 105 1051 1 011 0110110 100100 1 0 5 1109910 11 0 2 10 3 1 0 4 106 107 1081091111001051109697 98 99101102103104106107108109111 112 113 105105105 110115 115 115 115 115 120 12 0 100 1 0 5 110 115 119 120AND FILTER STRIP (A) PROP. LEVEL SPREADER PROP. FENCE (TYP.) PROP. FENCE (TYP.) P/L P/L PROP. STORMWATER MANAGEMENT BASIN PAGE 637 EASEMENT D.B. 1019. EX. 30' POWER LINE P.B. 2. PAGE 151A DEVLOPMENT CORP EDGECOMBE COUNTY EX. 60' EASEMENT FOR 98 98 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:38 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 15CG-115 1" = 40' 211 0 40'80'20'40' GRAPHIC SCALE:1" = 40' 95+00 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-117MATCH LINESEE DRAWING NO. CG-115MATCH LINESEE DRAWING NO. CG-130 MATCH LINE SEE DRAWING NO. CG-103 MATCH LINE 3862-32-8825 CSX TRANSPORTATION, INC. 3862-43-5381 CSX TRANSPORTATION, INC. EX. DIRT ROAD (TRM) (TYP.)P/LP /L EX. DIRT ROAD (TRM) (TYP.) PROP. ST06 TRACK PROP. ST07 TRACK EX. DIRT ROAD (TRM) (TYP.) EX. WETLAND (TRM)EX. WETLAND (TRM) PROP. C/L DITCH PROP. C/L DITCH EX. DIRT ROAD (TRM) (TYP.) 111 1 1 0110 1 1 1 115112 1 1 3 114115 120 122 113 113 111 111 1 0 8108 115 113 111 111 114 110 110 1 14 114 113 114115120113 114116117118119120 117 118 119 121 122 115115115 110110 112 112 114 112 114 115 PROP . GRAVE L ACCESS DR IVE PROP . GRAVEL ACCESS DR IVE P/L PROP. FENCE (TYP.) P/L with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:39 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 16CG-116 1" = 40' 212 0 40'80'20'40' GRAPHIC SCALE:1" = 40' 85+0090+00 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-118MATCH LINESEE DRAWING NO. CG-116MATCH LINESEE DRAWING NO. CG-131 MATCH LINE SEE DRAWING NO. CG-104 MATCH LINE 3862-43-5381 CSX TRANSPORTATION, INC. 3862-43-8706 CSX TRANSPORTATION, INC. 3862-43-5381 CSX TRANSPORTATION, INC. 3862-44-2350 CSX TRANSPORTATION, INC. 3862-44-2350 CSX TRANSPORTATION, INC. 3862-32-8825 CSX TRANSPORTATION, INC. P /L P /L P/L P/ LP/ LP/ L P/L P/ L P/ L EX. WAT. STR (TRM)P/ L PROP. ST06 TRACK PROP. ST07 TRACK EX. DIRT ROAD (TRM) (TYP.) PROP. WAT. (TYP.) PROP. WAT. (TYP.)P/ L PROP. ST06 TRACK PROP. ST07 TRACK EX. DIRT ROAD (TRM) (TYP.) PROP. C/L DITCH PROP. C/L DITCH 120116117118119121122 115 115 115 115 120 125 120 120 120 120 125 127 126 121 122 117 118 117 121 118 118 116 117 116 1 2 0 12 5 1 25 122 123 124126127127128128 126 126 127115 116 117 118 119 120 121 122 121 ACCESS DRIVE PROP. GRAVEL P/L P/LPROP. FENCE (TYP.) 4 RIM=121.87 PROP. 18" STM. PROP. 18" STM. HW11 BH1 INV=118.02 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:40 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 17CG-117 1" = 40' 213 0 40'80'20'40' GRAPHIC SCALE:1" = 40' 75+0080+00 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-119MATCH LINESEE DRAWING NO. CG-117MATCH LINESEE DRAWING NO. CG-132 MATCH LINE SEE DRAWING NO. CG-105 MATCH LINE 3862-54-0840 CSX TRANSPORTATION, INC. 3862-54-0840 CSX TRANSPORTATION, INC. 3862-44-2350 CSX TRANSPORTATION, INC. 3862-44-3619 CSX TRANSPORTATION, INC. 3862-55-2186 CSX TRANSPORTATION, INC. 3862-44-3619 CSX TRANSPORTATION, INC. P/ L P/L P/ L P/L P/ L P/ L P/ L PROP. ST07 TRACK PROP. ST06 TRACK P/L P/ L P/ L PROP. C/L DITCH PROP. C/L DITCH 123 124 120 120 127 125 120 124 124 123 126 122 122 122 128 123 120120 122 122 121 126127128 126 12712712 71281 2 8 126 126126 125125127 125125 126 127 128 1 2 7127128 126 126 127 125125127 126 126 127126 126 122 125 123 125 120 123 EX. C/L DITCH (TRM) EX. STM. (TRM) EX. 15" STM. (TRM) (FV) EX. C/L DITCH (TRM) EX. 15" STM. (TRM) (FV) EX. C/L DITCH (TRM) EX. C/L DITCH (TRM) ACCESS DRIVE PROP. GRAVEL EX. CONC. PAVEMENT (TRM) 5 RIM=123.69 PROP. 30" STM. PROP. 30" STM. BH3 BH2 PROP. GRAVEL ACCESS DRIVE with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:41 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 18CG-118 1" = 40' 214 0 40'80'20'40' GRAPHIC SCALE:1" = 40' 65+0070+00 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-120MATCH LINESEE DRAWING NO. CG-118MATCH LINESEE DRAWING NO. CG-133 MATCH LINE SEE DRAWING NO. CG-106 MATCH LINE PROP. PT08 TRACK 3862-55-2186 CSX TRANSPORTATION, INC. 3862-56-2216 CSX TRANSPORTATION, INC. 3862-45-5921 CSX TRANSPORTATION, INC. PROP. GRAVEL ACCESS DRIVE P/ L P/ L P/L P/L PROP. ST07 TRACK PROP. ST06 TRACK PROP. X-OVER PROP. ST06 TRACK PROP. ST07 TRACK P/ L PROP. C/L DITCH PROP. C/L DITCH 125 125125 124 124 122122 125 125 125 125 125 125 123 123 126 126 126 125124 125 125125 125126 126 127 1 2 6 125 125126 125125 126 126 126126 1251221231 2 4 1 2 5 121 122 12312412 6 126126127125 124 125125 124 125 126 126 127 126 125 124 125124 126 123121121123 120 119 119 120 121 121 PROP. HML (TYP.) 123 121 121 125 122 122 124 124 EX. GRAVEL (TRM) EX. GRAVEL (TRM) EX. C/L DITCH (TRM) EX. C/L DITCH (TRM) EX. C/L DITCH (TRM) EX. C/L DITCH (TRM) EX. 12" STM. (TRM) (FV) EX. 15" STM. (TRM) (FV) ACCESS DRIVE PROP. GRAVEL EX. GRAVEL (TRM) 6 RIM=125.20 PROP. 30" STM. PROP. 30" STM. BH4 BH5 PROP. GRAVEL ACCESS DRIVE HW41 HW40 HW39 HW38 INV=120.81 INV=120.77 PROP. 12" STM.PROP. 12" STM. INV=121.67 INV=121.91 PROP. FENCE (TYP.) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:42 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 19CG-119 1" = 40' 215 0 40'80'20'40' GRAPHIC SCALE:1" = 40' 55+0060+00 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-121MATCH LINESEE DRAWING NO. CG-119MATCH LINESEE DRAWING NO. CG-134 MATCH LINE SEE DRAWING NO. CG-107 MATCH LINE PROP. ST06 TRACK PROP. ST07 TRACK PROP. PT04 TRACK PROP. PT05 TRACK PROP. PT06 TRACK PROP. PT07 TRACK PROP. PT08 TRACK PROP. PT08 TRACK PROP. GRAVEL ACCESS DRIVE 3862-56-2216 CSX TRANSPORTATION, INC. 3862-67-2716 CSX TRANSPORTATION, INC. P/L PROP. 10" UD PROP. 10" UD PROP. AIR LINE (TYP.) PROP. C/L DITCH PROP. C/L DITCH 37 RIM=127.13 36RIM=127.45PROP. 8" UD 35RIM=127.77 PROP. 15" UD 30 RIM=127.14 PROP. 48" STM. CULVERT HW1 INV=118.17 125 125 125 127 127 124 124 125 125 125 125 125 127 126 123 123 127126 120 126 126 126 125 125 126 125 124 124 126 125 123 123 125 126 127120120 125125125125121121122122123123124124 1261261 2 612 712712 5 122 123 12412612 6 121 12012112 212 3119120 1 2 1 122 1231201201251191191 2 1 121122122122122 1231231 2 4124126126 1251241241 2 0118118 1 1 7118120 119 PROP. HML (TYP.) RIM=127.33 41 PROP. 12" UD 127 125 122 127 127 PROP. C/L DITCH 120120118118120120120EX. GRAVEL (TRM) EX. C/L DITCH (TRM) PROP. GRAVEL ACCESS DRIVE EX. GRAVEL (TRM) EX. COMMUNICATION TOWER (TRM) HW42 HW43 INV=117.67 INV=117.71 PROP. 48" STM. with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/28/20199:33:26 AMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 20CG-120 1" = 40' 216 0 40'80'20'40' GRAPHIC SCALE:1" = 40' 50+0055+00 1.00%1.00%JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-122MATCH LINESEE DRAWING NO. CG-120MATCH LINESEE DRAWING NO. CG-135 MATCH LINE SEE DRAWING NO. CG-108 MATCH LINE PROP. WHEELED PARKING (TYP.) PROP. TRANSFER STAGING (TYP.) PROP. CONTAINER STACKING (TYP.)PROP. CONTAINER STACKING (TYP.) PROP. BARRIER WALL (TYP.) PROP. BARRIER WALL (TYP.) PROP. 30" STM. PROP. 48" STM. PROP. 15" UD PROP. 12" UD PROP. 18" UD PROP. 10" UD PROP. 18" SD PROP. 18" SDPROP. 18" SD 3862-56-2216 CSX TRANSPORTATION, INC. 3862-67-2716 CSX TRANSPORTATION, INC.P/ L PROP. PT02/ST06 TRACKPROP. PT03/ST07 TRACK PROP. CRANE RAIL 1 PROP. PT04 TRACK PROP. PT05 TRACK PROP. PT06 TRACK PROP. PT07 TRACK PROP. PT08 TRACK PROP. CRANE RAIL 2 P/L LINE (TYP.) PROP. FIRE PROP. FIRE LINE (TYP.) PROP. AIR LINE (TYP.) LINE (TYP.) PROP. AIR PROP. AIR OUTLET (TYP.) 29 34 PROP. 15" UD PROP. 10" UD 15 14 13 12 11 31 RIM=127.78 RIM=126.78 RIM=128.67 RIM=127.78 RIM=128.67 RIM=128.90 38 32 27 PROP. 12" UD PROP. 15" UD PROP. 18" SD RIM=127.78 RIM=128.67 39 33 28 RIM=127.78 RIM=128.67 RIM=127.33 PROP. 30" STM. PROP. 36" STM. PROP. 36" STM. RIM=128.90 RIM=128.90 RIM=122.09 PROP. C/L DITCH PROP. C/L DITCH PROP. 10" UD PROP. 12" UD 125 125 125 125 127 127 127 128 128 129 129 129 129 128 127 127 127 127 127 122 123 127128129128 121 125 125 127 127 127 128 128 129 129 129 129 128 127 127 127 127 127 122 128 128127127126 127 125 126 127129124 125 127 123 125 12412612512412 5 1261271 2 8 125 1241261 2 7 128123123124125124 125123124 1 2 6 127128 129 129 122 123 1231241251 2 3 1241261 2 7 128122121121122 PROP. C/L DITCH PROP. C/L DITCH 125 125 INV=119.07 HW15 PROP. HML (TYP.) PROP. HML (TYP.) PROP. FHPROP. FH RIM=127.33 PROP. 12" UD PROP. 15" UD 40 PROP. 15" UD RIM=127.3342 PROP. 12" UD RIM=127.33 43 PROP. 12" UD 127 127 127 125 124 124 127 125 1 2 8 1 2 7 1 2 7 127 127124PROP. GRAVEL ACCESS DRIVE PROP. 12" STM. PROP. 42" STM. 26 RIM=128.90 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:44 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 21CG-121 1" = 40' 217 0 40'80'20'40' GRAPHIC SCALE:1" = 40' 40+0045+00 1.00%1.00%JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-123MATCH LINESEE DRAWING NO. CG-121MATCH LINESEE DRAWING NO. CG-136 MATCH LINE SEE DRAWING NO. CG-109 MATCH LINE PROP. WHEELED PARKING (TYP.) PROP. TRANSFER STAGING (TYP.) PROP. CONTAINER STACKING (TYP.)PROP. CONTAINER STACKING (TYP.) PROP. BARRIER WALL (TYP.)PROP. BARRIER WALL (TYP.) PROP. 48" STM. PROP. 30" STM. PROP. 10" UD PROP. 12" UD PROP. 18" SD 3862-67-2716 CSX TRANSPORTATION, INC. PROP. NORTH RIP TRACK PROP. PT02/ST06 TRACK PROP. PT03/ST07 TRACK PROP. PT04 TRACK PROP. CRANE RAIL 1 PROP. PT05 TRACK PROP. PT07 TRACK PROP. PT08 TRACK PROP. CRANE RAIL 2 PROP. PT06 TRACK PROP. FIRE LINE (TYP.)PROP. FIRE LINE (TYP.) PROP. "12" UD PROP. 10" UD 50 47 44 20 19 18 17 16 PROP. 18" SD RIM=127.78 RIM=128.67 RIM=128.90 PROP. 12" UD PROP. 18" UD PROP. 18" SD RIM=128.90 RIM=128.67 RIM=127.78 RIM=127.33 PROP. 36" STM. PROP. 36" STM. PROP. 36" STM. PROP. 18" UD PROP. 12" UD PROP. 18" SD PROP. 15" UD PROP. 12" UD 54 51 48 45 RIM=127.78 RIM=128.67 RIM=128.90 RIM=122.09 PROP. 42" STM. RIM=127.33 125 125 127 127 127 128 128 129 129 129 129 128 127 127 127 127 127 128 128 125 125 127 127 127 128 128 129 129 129 129 128 127 127 127 127 127 128 128 127 127 127 125 124126 127127 123 122 122 123 1 2 4 12 5 127 1261261 2712712712 8 125125124124126126127127127128129 1231 2 71281291291 2 5 1 2 5 1 2 6 126126 127 127 125 125 125 123 123 124 126PROP. C/L DITCH PROP. C/L DITCH PROP. C/L DITCH HW17 INV=119.06 PROP. HML (TYP.) PROP. HML (TYP.) PROP. 12" UD RIM=127.33 53 PROP. 15" UD 125 123 123 127 124 127 129 PROP. GRAVEL ACCESS DRIVE ACCESS DRIVE PROP. GRAVEL PROP. FH PROP. CRANE VAULT EX. C/L DITCH (TRM) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:45 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 22CG-122 1" = 40' 218 0 40'80'20'40' GRAPHIC SCALE:1" = 40' 30+0035+00 1.00%1.00%JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-124MATCH LINESEE DRAWING NO. CG-122MATCH LINESEE DRAWING NO. CG-137 MATCH LINE SEE DRAWING NO. CG-110 MATCH LINE PROP. WHEELED PARKING (TYP.) PROP. TRANSFER STAGING (TYP.) PROP. CONTAINER STACKING (TYP.)PROP. CONTAINER STACKING (TYP.) PROP. BARRIER WALL (TYP.)PROP. BARRIER WALL (TYP.) PROP. 30" STM. PROP. 48" STM. 3862-67-2716 CSX TRANSPORTATION, INC. 3863-71-6244 CSX TRANSPORTATION, INC. P/L PROP. PT02/ST06 TRACK PROP. PT03/ST07 TRACK PROP. CRANE RAIL 1 PROP. PT04 TRACK PROP. PT05 TRACK PROP. PT07 TRACK PROP. PT06 TRACK PROP. PT08 TRACK PROP. NORTH RIP TRACK PROP. CRANE RAIL 2 P/LPROP. 48" DUAL STM. CULVERT EX. STREAM BUFFER PROP. FIRE LINE (TYP.)PROP. FIRE LINE (TYP.) PROP. 12" UD PROP. 10" UD PROP. 12" UD PROP. 18" SD 55 52 49 46 RIM=128.67 RIM=127.78 RIM=127.33 PROP. 12" UD PROP. 10" UD PROP. 12" UD 65 62 59 56 RIM=127.33 RIM=127.78 RIM=128.67 RIM=128.90 PROP. 18" SD PROP. 18" SD PROP. 18" UD PROP. 12" UD PROP. 15" UD 25 24 23 22 RIM=127.33 RIM=127.78 RIM=128.67 RIM=128.90 PROP. 30" STM. PROP. 36" STM. PROP. 36" STM. PROP. 42" STM. 21RIM=122.09 PROP. 12" UD PROP. 12" UD PROP. 18" UD PROP. 18" SD HW3 INV=112.33 120 125 125 125 127 127 127 128 128 129 129 129 129 128 127 127 127 127 127 128 128 127 127 125 125 125 127 127 127 128 128 129 129 129 129 128 127 127 127 127 127 128 128 127 127 122 1201 2 0 121121121122123 1201251211221231241261271271201251 2 1 1 2 2 1 2 3 124126 12 0 125119 12 1 1 2 2 1 2 3 124126127 127 12012511811912112212312412612 0 1251191211 2 2 123 124 1201251 1 611 6117118119121122123124126120117 1 1 8 11912112112112212 2 1 2 2 1231181 1 9 118 1 1 7 1 1 7 116116 125 123 124 126 1 1 6 1 1 6 117 121 120 120 121119119 117 PROP. C/L DITCH PROP. C/L DITCH RIM=128.90 PROP. HML (TYP.) PROP. FH PROP. HML (TYP.)115113113116116ACCESS DRIVE PROP. GRAVEL PROP. GRAVEL ACCESS DRIVE with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:46 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 23CG-123 1" = 40' 219 0 40'80'20'40' GRAPHIC SCALE:1" = 40' 20+00 25+00 1.00%JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-125MATCH LINESEE DRAWING NO. CG-123MATCH LINESEE DRAWING NO. CG-138 MATCH LINE SEE DRAWING NO. CG-111 MATCH LINE 37+0038+0039+00 BUILDING ROADABILITY PROP. WELFARE BUILDING PROP. ADMINISTRATIVE/ BUILDING PROP. MAINTENANCE BUILDING PADPROP. CAR REPAIR ACCESS DRIVEPROP. GRAVEL (TYP.) FENCE PROP. PROP. GATEPROP. GATE GATE PROP. GATE PROP. PROP. WHEELED PARKING (TYP.) PROP. TRANSFER STAGING (TYP.) PROP. BARRIER WALL (TYP.) ACCESS DRIVEPROP. GRAVEL PROP. GRAVEL ACCESS DRIVE PROP. 12" UD PROP. 12" UD PROP. 8" UD PROP. 18" SD 3863-71-6244 CSX TRANSPORTATION, INC. PROP. NORTH RIP TRACK EX. GRAVEL (TRM) EX. GRAVEL (TRM) EX. C/L DITCH (TRM) PROP. CRANE RAIL 2 TRACK PROP. PT08 PROP. PT07 TRACK PROP. PT05 TRACKPROP. PT06 TRACK PROP. CRANE RAIL 1 PROP. PT03/ST07 TRACK PROP. PT02/ST06 TRACK PROP. PT04 TRACK PROP. PT04 TRACK PROP. ST07 TRACK PROP. PT04 TRACK PROP. PT05 TRACK PROP. PT08 TRACK READY TRACK PROP. NORTH ENGINE PROP. SAN. (TYP.) SERV. (TYP.) PROP. SAN. PROP. FIRE LINE (TYP.) PROP. WAT. SERV. (TYP.) PROP. FH (TYP.) LINE (TYP.)PROP. AIR (TYP.) OUTLET PROP. AIR PROP. FIRE LINE (TYP.) PROP. 18" UD PROP. 12" UD RIM=128.67 RIM=127.78 PROP. 10" UD PROP. 12" UD 66 63 60 RIM=127.33 67 RIM=127.33 PROP. 8" UD RIM=127.78 64 61 RIM=128.67 PROP. CONTAINER STACKING (TYP.)PROP. CONTAINER STACKING (TYP.) 57 RIM=128.90 PROP. 18" SD 58 RIM=128.90 RIM=126.55 75 PROP. 8" UD 76 RIM=126.50 74 RIM=125.33 PROP. 24" STM. RIM=125.17 73 PROP. 24" STM.PROP. 10" UD PROP. 24" STM. 81 RIM=123.31 125 125 125 127 127 127 128 128 129 129 129 129 128 127 127 127 127 127 128 128 127 127 123 124 124 125 122123 124 126127 125 123 124 126 127 129 127 128 129 122123125126127128125122123124126 127125 120 121122123124119 120119127128129127 127 127 129 127 127 126121 120 125123124 126 127 120121 115 114 114115116117118 120 116117118119119 120121122 1 2 5 123 1 2 4 1261 2 6 1 2 7 1271 2 6 12 5 12 5 12 6 126126 126 126 12 6 1 2 7 12712512 4 12 4 12 5 125 125 125 120125119121122123124126126 127127126127 125 122123124124122122124121 122 120120 122 PROP. C/L DITCH PROP. C/L DITCH PROP. C/L DITCH126126124 124 72 RIM=125.44 12812112 4 123 122 121 119 117118 118 118 117 PROP. C/L DITCH PROP. 24" STM. PROP. 24" STM. PROP. HML (TYP.) PROP. HML (TYP.) PROP. GRAVEL ACCESS DRIVE P/LPROP. FH PROP. 30" STM. RIM=120.38 79 RIM=123.87 80 PROP. 30" STM. 120 115 121 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:47 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 24CG-124 1" = 40' 220 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-126MATCH LINESEE DRAWING NO. CG-124MATCH LINESEE DRAWING NO. CG-139 MATCH LINE SEE DRAWING NO. CG-112 MATCH LINE 27+002 8 +0029+0030+0031+0032+0033+0034+0035+0036+00 PROP. TERMI NAL DRI VEACCESS DRIVE PROP. GRAVEL PROP. 36" STM. 3863-71-6244 INC. TRANSPORTATION, CSX PROP. PORTABLE CONCRETE BARRIER (TYP.) EX. GRAVEL (TRM) EX. POND/BASIN (TRM)EX. POND/BASIN (TRM) CULVERT PROP. 36" STM. EX. POND BUFFER EX. POND BUFFER EX. STREAM (TRM) EX. STREAM (TRM) BUFFER EX. STREAM EX. STREAM (TRM) EX. STREAM BUFFER EX. STREAM BUFFER PROP. WAT. (TYP.) PROP. WAT. (TYP.) PROP. SAN. (TYP.) 82 83 RIM=108.17 PROP. 36" STM.RI M=106.40HW32 HW6 HW31 INV=97.30 86RIM=103.34PROP. 36" STM.RI M=103.7887 INV=93.64121110115120111112113114116117118119 1 0 510610 7 10 8 10 9 1 0 0 1 0 4 1 0 0 10 4 9 1 9 295 9 7 9 7 9 0 9 5 9 6 8 9 105 1 0 3 1 0 4 1 0 0 9 6 9 7 9 8 100 104 97 98 103 121 110 120 111 110115 109111112113114116117118119 107108 1 0 4 1 0 3 1 0 3 9 8105 1 0 3 1 0 3 120 115 110 115 110 95 96979899 101 102 103104104 10010511011599101102103104106107108109111112113114116 1 0 0 97 98 9 9 1011021039795110 110115 110 110110100100100100105117 118 119 1051101151201031 0 4 10610710810 9 1 1 1 1 1 2 113114 1 1 6 117 1 1 8 121104105 110115 1 0 8109111112113 114116117118107 1001059899101102103104106 9795 9494PROP. C/L DITCH PROP. C/L DITCH 1 0 4 PROP. C/L DITCH PROP. STORMWATER MANAGEMENT BASIN 100 119 122121 122 117118 118 117 1 0 5 10 5 1 0 6 120 115 110 106108108107107 107 105PROP. C/L DITCH 1 0 3 1 0 2 1 0 2 PROP. 24" STM. PROP. 36" STM. 89RIM=1 0 2. 3 1 I NV= 9 6. 8 0 PROP. HML (TYP.)PROP. LI GHT POLE115 110 105 115 119 105 105 110 110 10 0 10 5 105100112111110109108107106PROP. C/L DITCH (TYP.)PROP. HML (TYP.)BOLLARDPROP. PROP. FENCE (TYP.)P/LP/LP/L EX. C/L DITCH (TRM) PROP. FENCE (TYP.) HW26 INV=111.66 85RIM=116.93 PROP. 24" STM.PROP. 24" STM. 84RIM=112.43 HW29 HW30 115 PROP. 30" STM. 1 1 9 PROP. 36" STM.98INV=97.30 INV=98.59 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:49 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 25CG-125 1" = 40' 221 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-127MATCH LINESEE DRAWING NO. CG-125MATCH LINESEE DRAWING NO. CG-140 MATCH LINE SEE DRAWING NO. CG-113 MATCH LINE 17+00 18+00 19+00 20+00 21+0022+00 23+0024+0025+0026+0 027+00TERMINAL DRIVE PROP. RETURN TO PROP. TERMINAL DRIVE PROP. TERMINAL DRIVE PROP. 12" STM. 3863-71-6244 CSX TRANSPORTATION, INC. EX. STREAM BUFFER LIMITS OF 500 YEAR FLOOD HAZARD EX. STREAM (TRM) EX. STREAM BUFFER EX. WETLAND (TRM) EX. STREAM BUFFER LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF 100 YEAR FLOOD HAZARD EX. WETLAND (TRM)EX. WETLAND (TRM) EX. WETLAND (TRM)EX. WETLAND (TRM) EX. STREAM BUFFER EX. STREAM (TRM) LIMITS OF 100 YEAR FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF 100 YEAR FLOOD HAZARD HW5 INV=92.04 PROP. 36" STM. CULVERT90 RIM=102.31 1 0 5 106 1 0 0 107 108 109 90 95 100 103 104 97 98 89 90 95 100 89 96 97 98 103 104 100101 10510510597 106 10 6 1 0 5105108 110 109 109 108 1071071 0 4 1 0 310 310 01 0 4 1041031 0 3 108 1089510096 9 7 9 8 99101102 95 100 101 102 103 104105 106 107 11011010810910995 100 10596 97 98 99 1011021031041061071089596979899100 101102 100 97 98 99 98 99 10 8 107 108 109 95 1 0 0 105 90 90100 105 110 111 105104106107 107 9593 9395 9393 95 90 90 PROP. C/L DITCH PROP. C/L DITCH PROP. C/L DITCH PROP. C/L DITCH PROP. C/L DITCH PROP. STORMW ATER MANAGEMENT BASIN 105 109 1 0 3 1 0 2 1 0 2 105 107 108107 107108 109104RIM=98.07 88 PROP. 24" STM. 103 103 PROP. LIGHT POLE (TYP.) 105 95 9596 97 9393 9997HW33 INV=96.93 PROP. LEVEL SPREADER (D) PROP. FENCE (TYP.) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:50 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 26CG-126 1" = 40' 222 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-128MATCH LINESEE DRAWING NO. CG-126MATCH LINESEE DRAWING NO. CG-141 MATCH LINE SEE DRAWING NO. CG-114 MATCH LINE 12+0013+00 14+00 15+0016+00 17+00 PROP. TERMINAL DRIVE 3863-71-6244 CSX TRANSPORTATION, INC.EX. STREAM (TRM) EX . 2 7 " SAN . (TRM ) (P LAN )INV.(W)=80.89 (PLAN) INV.(E)=80.83 (PLAN) RIM=93.04 (FV) EX. SAN. MH (TRM) EX. 27" SA N. (T R M) (PLA N) EX. 27" SA N. (T R M) (PLA N)INV.(W)=81.32 (PLAN) INV.(E)=81.25 (PLAN) RIM=93.61 (FV) EX. SAN. MH (TRM) EX. C/L DIT C H (T R M) EX. STREAM BUFFER EX. WETLAND (TRM)EX. WETLAND (TRM) EX. 30' PE R MA NE NT EASE ME NT (PLA N) LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF FLOOD HAZARD EX. WETLAND (TRM)EX. WETLAND (TRM) EX. WETLAND (TRM)EX. WETLAND (TRM)LIMI T S O F F LO O D H A Z A R D E X. S T R E AM B U F F E R LI MITS OF FLO OD HAZARD EX. STREA M BUFFER LIMI TS O F FLO O D H AZAR D EX. STREAM BUFFER EX. W E T LAND (TRM )EX. W E T LAND (TRM )LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF 100 YEAR FLOOD HAZARD LIMITS OF 100 YEAR FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF 100 YEAR FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD 1 0 5 110 110 1 0 6 1 0 7 1 0 8 10 9 110 110 110 110 103 96100103105 105 110 101 102 103 103 103 104 106 1 0 7 1 0 8 1 0 9 95 100 94 9697 98 99 9 0 8 9 9 1 929394898 9 89 100 90 90 90 909 5 1 0 096979 8 9 9 9095 89 9192 93 94 96979899 95 96 97 9899908 9 91 92 9 3 94 PROP. C/L DITCH PROP. C/L DITCH LIMITS OF 100 YEAR FLOOD HAZARD 109 109 110 108 108 105 PROP. LIGHT POLE (TYP.) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:51 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 27CG-127 1" = 40' 223 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 ASEE DRAWING NO. CG-127MATCH LINESEE DRAWING NO. CG-142 MATCH LINE 3863-71-6244 CSX TRANSPORTATION, INC. 3863-84-9571 EDGECOMBE GENCO LLC EX. SAN. CONCRETE ENCASEMENT (TRM) INV.(S)=81.87 INV.(N)=81.92 EX. SAN. MH (TRM) (PLAN) EX. STM. CULVERT (TRM) EX. EDGE OF GRAVEL (TRM) PROP. GAS MAIN (BY OTHERS)P/LP/L P/LEX. 30' PERMANENT EASEMENT EX. STREAM (TRM) EX. STREAM (TRM) (TRM) (PLAN)EX. 27"SAN. INV.(SW)=78.84 27" RCP INV.(E)=78.53 27" RCP INV.(N)=79.69 10" RCP RIM=89.97 EX. SAN. MH (TRM) (FV) EX. 10" SAN. (TRM) (FV)EX. 10" SAN. (TRM) (PLAN)EX. 27" SAN. (TR M) (PLAN) INV.(SW)=79.03 27" RCP INV.(NE)=79.03 27" RCP RIM=90.43 EX. SAN. MH (TRM) (FV)EX. 27" SAN. (TRM) (PLAN) INV.(W)=80.52 (PLAN) INV.(E)=80.48 (PLAN) RIM=91.30 (FV) EX. SAN. MH (TRM) EX . 2 7 " SAN . (TRM ) (P LAN )(BY OT HERS)PROP. GAS MAI N EX. EDGE OF GRAVEL (TRM) L IM ITS OF FLOOD HAZARD LIMITS OF 100 YEAR FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD EX. STREAM BUFFER EX . STREAM BUFFER EX . WETLAND (TRM )LIMITS OF FLOOD HAZARD EX. WETLAND (TRM)EX. WETLAND (TRM)EX. 30' PERM ANENT EASEM ENT (PLAN) LIMITS OF 100 YEAR FLOOD HAZARD EX. STREAM (TRM) E X. G R A V E L ( T RM ) LIMITS OF FLOOD HAZARD EX. WETLAND (TRM) EX. WETLAND (TRM)EX. WETLAND (TRM) EX. STREAM BUFFER FLOOD HAZARD LIMITS OF LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF 100 YEAR FLOOD HAZARD EX. WETLAND (TRM)EX. WETLAND (TRM) FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF 100 YEAR LIMITS OF 100 YEAR FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD EX. FENCE (TRM) (TYP.)LIMITS OF 100 YEAR FLOOD HAZARDLIMITS OF 500 YEAR FLOOD HAZARDEX. FENCE (TRM) (TYP.)EX. BRIDGE (TRM) EX. STREAM (TRM) 110 106107 108 109 105 100 99 101 9697 98 90 9588 8 991929394 95 90 90 95100 8889 91 92 93 94 9697 9899 100 9798991011029695 94 90 888991929394 8787 87 8788 888888 89 90 101102 10099 909587888991929394969798 8887 90 89 90 88 89 91 9293 9 0 8 8 878787888 987 87 88 8 8 878787 87 9088888 7 87 8 7 88 87 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:52 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 28CG-128 1" = 40' 224 0 40'80'20'40' GRAPHIC SCALE:1" = 40'NO WORK THIS SHEET JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-130MATCH LINESEE DRAWING NO. CG-115 MATCH LINE 3862-31-8523 ROCKY MOUNT/EDGECOMBE COMM DEV 3862-41-3409 ROBYN ROSCOE 3862-41-2881 ROBYN ROSCOE 3862-32-8825 CSX TRANSPORTATION, INC. 3862-42-8047 CSX TRANSPORTATION, INC. E X. P A V E ME NT ( T RM) E X. P A V E ME NT ( T RM) EX. SIGN (TRM) ( T RM) ( T Y P.) E X. CURB & GUT T E REX. POND/BASIN (TRM) EX. POND/BASIN (TRM) EX. SAN. (TRM) P/ L P/L P/ L P/ L P/ L P/ L P/L P/ L P/L EX. BUILDING (TRM)EX. BUILDING (TRM) EX. SIGN (TRM) EX. NATURAL GAS LINE (TRM) EX. OVERHEAD ELEC. (TRM) EX. CURB & GUTTER (TRM) EX. DRIVE (TRM) EX. NATURAL GAS LINE (TRM) EX. NATURAL GAS LINE (TRM) EX. C/L DITCH (TRM) EX. OVERHEAD ELEC. (TRM) EX. POW ER POLE (TRM) EX. C/L DITCH (TRM) EX. WETLAND (TRM) EX. STREAM (TRM) EX. STREAM BUFFER EX. WETLAND (TRM)EX. WETLAND (TRM) EX. STREAM BUFFER115115115115115115115115110 115 110 110 110110110 110 110 110105105 105 105 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:53 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 29CG-129 1" = 40' 225 0 40'80'20'40' GRAPHIC SCALE:1" = 40'NO WORK THIS SHEET JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-131MATCH LINESEE DRAWING NO. CG-116 MATCH LINE SEE DRAWING NO. CG-129MATCH LINE3862-32-8825 CSX TRANSPORTATION, INC. 3862-42-8047 CSX TRANSPORTATION, INC. 3862-43-5381 CSX TRANSPORTATION, INC. P/L P/ L EX. DIRT ROAD (TRM) (TYP.)P/LP/LP /L EX. DIRT ROAD (TRM) (TYP.) EX. C/L DITCH (TRM) EX. STREAM BUFFER EX. STREAM (TRM) EX. STREAM BUFFER EX. WETLAND (TRM)EX. WETLAND (TRM) EX. WETLAND (TRM)EX. WETLAND (TRM) EX. STREAM (TRM) EX. STREAM BUFFER EX. WETLAND (TRM)EX. WETLAND (TRM) EX. WETLAND (TRM)EX. WETLAND (TRM) EX. STREAM (TRM) EX. STREAM BUFFER EX. STREAM BUFFER1051 1 0110110 105105105 110110 110110 110 110 110 110 110 1 1 0 11010510 5 105105 105105 115 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:54 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 30CG-130 1" = 40' 226 0 40'80'20'40' GRAPHIC SCALE:1" = 40'NO WORK THIS SHEET JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-132MATCH LINESEE DRAWING NO. CG-117 MATCH LINE SEE DRAWING NO. CG-130MATCH LINE3862-43-5381 CSX TRANSPORTATION, INC. 3862-43-8706 CSX TRANSPORTATION, INC. 3862-43-8706 CSX TRANSPORTATION, INC. 3862-43-5381 CSX TRANSPORTATION, INC. 3862-54-4122 CSX TRANSPORTATION, INC. 3862-43-5381 CSX TRANSPORTATION, INC. 3862-44-2350 INC. TRANSPORTATION CSX 3862-32-8825 CSX TRANSPORTATION, INC. C OLLE GE R D EX. FH (TRM) EX. 6" BFV W/ BOX (TRM) (PLAN) EX. 6" WAT. LINE (TRM) (PLAN) EX. BUILDING (TRM) EX. BUILDING (TRM) EX. BUILDING (TRM) EX. BUILDING (TRM) EX. BUILDING (TRM) EX. BUILDING (TRM) EX. STM. CULVERT (TRM)PAVEMENT (T RM)EX. ASPHAL T (TRM) EX. STM. CULVERT EX. SIGN (TRM) EX. FENCE (TRM) (TRM) EX. BUILDING P /L P/ L EX. BOLLARD (TRM)P/ LP/ L P/ L P/ L P/L P/L P/L R/WP/ L R/WR/WR/W P/ L EX. WAT. STR (TRM) (TRM) POLE LIGHT EX. EX. DIRT ROAD (TRM) WAY (TRM) EX. 60' RIGHT OF EX. 16" WAT. LINE (TRM) (PLAN) EX. C/L DITCH (TRM) (TYP.) FINAL ID A-2 EX. ESA WELL FINAL ID 324 EX. ESA WELL EX. BOLLARD (TRM) EX. SIGN (TRM) FINAL ID A-1 EX. ESA WELL EX. DIRT ROAD (TRM) EX. WETLAND (TRM)EX. WETLAND (TRM) EX. STREAM (TRM) EX. STREAM BUFFER EX. STREAM BUFFER PROP. WAT. (TYP.)115120125115120125 1201251301 2 5 124126 130130 130130 130 130130 130130130130 128 128129128 129128 129 128 127 EX. C/L DITCH (TRM) (TYP.) EX. 15" STM. (TRM) (FV) PROP. ROADWAY TURNAROUND R/WR/WEX. C/L DITCH (TRM) (TYP.) EX. BUILDING (TRM) PROP. FENCE (TYP.) P/LP/LPROP. GRAVEL ACCESS DRIVE with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:56 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 31CG-131 1" = 40' 227 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-133MATCH LINESEE DRAWING NO. CG-118 MATCH LINE SEE DRAWING NO. CG-131MATCH LINE3862-54-4122 CSX TRANSPORTATION, INC. 3862-44-2350 CSX TRANSPORTATION, INC. 3862-44-3619 CSX TRANSPORTATION, INC. 3862-54-1769 CSX TRANSPORTATION, INC. 3862-54-0840 CSX TRANSPORTATION, INC. 3862-55-2186 CSX TRANSPORTATION, INC. P/L P/L EX. C/L DITCH (TRM) P/ L P/ L P/ L P/L P/ L P/L P/ L P/ L EX. POND/BASIN (TRM)EX. POND/BASIN (TRM) P/L EX. DIRT ROAD (TRM) EX. WETLAND (TRM)EX. WETLAND (TRM) EX. WETLAND (TRM)EX. WETLAND (TRM) 1 2 5 125125125 125125125 126127128128 127 128 127 127 128 127128126127 128 127 126 125 126127 127126 126 126126 EX. C/L DITCH (TRM) EX. C/L DITCH (TRM) PROP. FENCE (TYP.) P/LP/L PROP. GRAVEL ACCESS DRIVE PROP. FENCE (TYP.) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:57 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 32CG-132 1" = 40' 228 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-134MATCH LINESEE DRAWING NO. CG-119 MATCH LINE SEE DRAWING NO. CG-132MATCH LINE3862-55-2186 CSX TRANSPORTATION, INC. 3862-44-3619 CSX TRANSPORTATION, INC. 3862-55-7165 CSX TRANSPORTATION, INC. 3862-54-4122 CSX TRANSPORTATION, INC. 3862-56-2216 CSX TRANSPORTATION, INC. P/ L EX. C/L DITCH (TRM) P/ L P/ L P/L P/L P/ L EX. GRAVEL (TRM) EX. WETLAND (TRM)EX. WETLAND (TRM) 125 126127 125121122123124 120120 119 119 1241251 2 5 1 2 5 125 12212 3124 120 1 2 1 124 125120 120 123 123 121120119 119 120121 119119 121 EX. GRAVEL (TRM) EX. 12" STM. (TRM) (FV) EX. C/L DITCH (TRM) PROP. FENCE (TYP.) P/LP/L PROP. FENCE (TYP.) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:58 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 33CG-133 1" = 40' 229 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-135MATCH LINESEE DRAWING NO. CG-120 MATCH LINE SEE DRAWING NO. CG-133MATCH LINE3862-56-2216 CSX TRANSPORTATION, INC. 3862-67-2716 CSX TRANSPORTATION, INC. P/L P/L P/L EX. C/L DITCH (TRM) EX. 24" STM. (TRM) EX. C/L DITCH (TRM) EX. WETLAND (TRM) EX. STREAM BUFFER EX. STREAM (TRM) EX. WETLAND (TRM)EX. WETLAND (TRM) EX. STREAM BUFFER EX. STREAM (TRM) EX. STREAM BUFFER 121 119 120119121121 122122 12312 3 1181 2 0 1161171181191 2 1 120 119118119 1201191 2 0 120125 125120 1251171181191211221231241 1 6 120 120 121 122123 124 119 118 117118 118117118PROP. C/L DITCH 118118119119PROP. FENCE (TYP.) P/LP/L PROP. FENCE (TYP.) EX. STREAM BUFFER with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:42:59 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 34CG-134 1" = 40' 230 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-136MATCH LINESEE DRAWING NO. CG-121 MATCH LINE SEE DRAWING NO. CG-134MATCH LINE3862-67-2716 CSX TRANSPORTATION, INC. EX. C/L DITCH (TRM) PROP. 48" STM. 110 110 115 115 120 120 125 130 130 122 116 108109 109 125 125 115 115 115 115 120 120 125 125 130 130 135 135 127 116 128 129 110 110 127 128126 124134 134 135134 136 137 124 12512 6 12712812912 9 125124123 126 124123 123124 125 125 12 5 130130 123 1251251241 2 4 12512 4 126 125 126 126127 128122 121 121122 122 123 1 24125123 124126127128123 PROP. MOUNDINGPROP. MOUNDING PROP. STORMWATER MANAGEMENT BASINPROP. STORMWATER MANAGEMENT BASIN HW14INV=111.54 PROP. FENCE (TYP.) P/LP/L with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:00 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 35CG-135 1" = 40' 231 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-137MATCH LINESEE DRAWING NO. CG-122 MATCH LINE SEE DRAWING NO. CG-135MATCH LINE3862-67-2716 CSX TRANSPORTATION, INC. EX. C/L DITCH (TRM) EX. C/L DITCH (TRM) EX. BUILDING (TRM) EX. BUILDING (TRM) PROP. 48" STM. 110 110 115 115 120 120 125 125 130 130 135 135 128 116 127 137 136 128 127 125 1 2 4 126127128 110 110 115 115 120 120 125 125 125 130 130 116 123 126 135 13 3 134 110 110 115 115 109127128129129 126126126 125125125125125 124126127128 129 1 2 6 1 2 5 1 2 4 1 2 4 1 2 5 1 2 6 1251221231 2 412612712 8 121 121 122 123 125 124 124 126 125 124 125 126127128 124122122 123 12412 4125120120120 121120 119119 120121 PROP. STORMWATER MANAGEMENT BASINPROP. STORMWATER MANAGEMENT BASIN PROP. STORMWATER MANAGEMENT BASINPROP. STORMWATER MANAGEMENT BASIN PROP. MOUNDINGPROP. MOUNDING PROP. MOUNDINGPROP. MOUNDING HW16 INV=114.85 EX. GRAVEL (TRM) PROP. FENCE (TYP.) P/LP/L with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:01 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 36CG-136 1" = 40' 232 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-138MATCH LINESEE DRAWING NO. CG-123 MATCH LINE SEE DRAWING NO. CG-136MATCH LINE3862-67-2716 CSX TRANSPORTATION, INC. 3863-71-6244 CSX TRANSPORTATION, INC. PROP. 24" STM.P/LEX. C/L DITCH (TRM)P/LPROP. 48" STM. EX. STREAM (TRM) EX. STREAM BUFFER EX. STREAM BUFFER INV=115.68 HW22 HW20INV=114.94 HW19 HW13 RIM=120.50 8 1 2 2 1 2 3 13 0 13 1 13 2 1 2 1 110 110 115 115 120 120 116 122 125 125 130 130 123 120123 125 125 130 130 123110116 122 110 110 115 115 131 132 107 118120119 115 117 117119 115115120125 116117118119121122123124120116117118 1 1 9 121120121125121122 123 124 121122123 12011912 1122123120 121 122 115116117118119115116117118119115 120116 1171181191 2 1 122123124120 125 117118119121 122123124116 115114110115120 120 120 12 0 115115 1 1 0 115 115115 12 0 125120120 125 115 11 5 110120119118 PROP. STORMWATER MANAGEMENT BASINPROP. STORMWATER MANAGEMENT BASIN PROP. MOUNDINGPROP. MOUNDING PROP. STORMWATER MANAGEMENT BASINPROP. STORMWATER MANAGEMENT BASIN PROP. MOUNDINGPROP. MOUNDING PROP. 36" STM. HW12 INV=113.75 7 9 10 RIM=115.95 PROP. 24" STM. PROP. 12" STM. HW18 INV=112.91 INV=114.15 120115115RIM=118.00 INV=114.50 115 115 114 114 116RIM=119.00 122 121 115 116 110 PROP. STORMWATER MANAGEMENT BASINPROP. STORMWATER MANAGEMENT BASIN 110 115 116 120 120 120 121 120 120 116 115120120117115113115116113112112PROP. FENCE (TYP.) P/LP/L AND FILTER STRIP (C) PROP. LEVEL SPREADER FILTER STRIP (B) SPREADER AND PROP. LEVEL PROP. 36" STM. PROP. 18" STM. PROP. 36" STM. BUFFER EX. STREAM BUFFER EX. STREAM PROP. FENCE (TYP.) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:02 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 37CG-137 1" = 40' 233 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-139MATCH LINESEE DRAWING NO. CG-124 MATCH LINE SEE DRAWING NO. CG-137MATCH LINEBUILDING MAINTENANCE PROP. FUELING PROP. HOSTLER PROP. GATE PROP. 36" STM. PROP. 30" STM. 3863-71-6244 CSX TRANSPORTATION, INC. PROP. FENCE EX. GRAVEL (TRM) EX. WAT. STR (TRM) EX. C/L DITCH (TRM) EX. C/L DITCH (TRM) PROP. FH PROP. FIRE LINE (TYP.)71 RIM=123.50 PROP. 36" STM. RIM=127.91 RIM=129.39 68 133 134125127128130125129125 130 130 133 133 126 126 125126 130 131131130130 1271 2 8128129 125 125 125126 121 125124126 125 125127128 126120119 124 125 120125 125 118119 121122123123124124126126 116 117 115 115 116 1161 2 5 121122123124126 12011611711811 9115125126126 1201251171181191211221231241261 2 6 115116 125 125 125 125 125 125125125125 125 1 1 5 120125126 112113114 PROP. C/L DITCH PROP. MOUNDINGPROP. MOUNDING 1 2 9 1 3 0 127 128 PROP. 24" STM. 70 RIM=127.74 PROP. 24" STM. PROP. HML (TYP.) PROP. LIGHT POLE 69 EX. GRAVEL (TRM) PROP. FENCE (TYP.) PROP. FENCE (TYP.)P/LP/LP/L 127126 OWS1 PROP. 36" STM.126124123122with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:03 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 38CG-138 1" = 40' 234 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-140MATCH LINESEE DRAWING NO. CG-125 MATCH LINE SEE DRAWING NO. CG-138MATCH LINE3863-71-6244 CSX TRANSPORTATION, INC.EX. 24" W AT. M AI N (TR M) ( P LAN) EX. 24" WAT. MAIN (TRM) (PLAN) EASEMENT (PLAN) EX. 40' WATER EX. C/L DITCH (TRM) EX. POND/BASIN (TRM)EX. POND/BASIN (TRM) EX. POND/BASIN (TRM)EX. POND/BASIN (TRM) BUFFER EX. STREAM EX. POND BUFFER EX. POND BUFFER EX. POND BUFFER EX. 40' WATER EASEMENT (PLAN) EX. POND BUFFER EX. STREAM (TRM) EX. STREAM BUFFER EX. STREAM (TRM) EX. STREAM BUFFER 1001 0 5 11011 5110 110110110 110 110 11010 5 105 105 105110105105 100 PROP. FENCE (TYP.) PROP. WAT. (TYP.) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:04 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 39CG-139 1" = 40' 235 0 40'80'20'40' GRAPHIC SCALE:1" = 40'NO WORK THIS SHEET JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-141MATCH LINESEE DRAWING NO. CG-126 MATCH LINE SEE DRAWING NO. CG-139MATCH LINETERMINAL DRIVE PROP. RETURN TO 3863-71-6244 CSX TRANSPORTATION, INC.EX. 24" W AT. M AI N (TR M) ( P LAN) EX. C/L DITCH (TRM)EX. F H ( T RM)BOX ( T RM) (PL AN)EX. 2 4 " BF V W/ EX. C/L DITCH (TRM) E X. 40' W A TE R E A S E M E N T ( P LA N) EX. GRAVEL (TRM) EX. C/L DITCH (TRM) (TRM) STREAM EX. EX. STREAM (TRM) EX. WAT. VALVE (TRM) EX. POND/BASIN (TRM)EX. POND/BASIN (TRM) 105 111110 110 110 105 110104106107108109 1 1 1111111 111 1101 0 5 10 6 10 7 108 110110110 1151091 11 112112112113114115 113114110 110110110105 105 105105 105105105105105105 105 105110110 DITCH PROP. C/L EX. STREAM BUFFER EX. STREAM BUFFER EX. STREAM BUFFER 110 103 103 109 105 PROP. FENCE (TYP.)P/L P/LP/Lwith the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:05 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 40CG-140 1" = 40' 236 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-142MATCH LINESEE DRAWING NO. CG-127 MATCH LINE SEE DRAWING NO. CG-140MATCH LINESEE DRAWING NO. CG-143 MATCH LINE 6+00 7+00 8+00 9+00 1 0 + 0 011+0012+00PROP. TERMINAL DRIVE PROP. 24" STM.3863-71-6244 CSX TRANSPORTATION, INC. 3863-82-6322 CSX TRANSPORTATION, INC. EX. BUILDING (TRM) EX. POWER POLE (TRM)P/ L P/L P/ L P/L EX. GRAVEL (TRM) FINAL ID 220 EX. ESA WELL EX. POWER POLE (TRM) LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD HW35 INV=97.34 102 103 104 9 6 1051 0 0 1 0 2 102100101 101102102 115 111 112 113 114 116117 118 119 120 121 115 113 1 1 4 116 117 118119 120121 122 12512312410096 9 7 9 8 99 101 102103979810 0 97 98 9 9 105 101102103104106 110 115 120 109 111 112 113114 116 117 118 119 1001051 1 01151 2 0 99101102 10310410610710 8109111112 1131 1 41161171 1 8 119 1 2 1 1 2 212 3124105110 10210310410610 7108109111 98 99 96 97 95 93 94 PROP. C/L DITCH PROP. C/L DITCH PROP. C/L DITCH 110 105 101 100 9798102PROP. LIGHT POLE (TYP.) 1 0 0 1 0 1 1 0 1 1 0 2 1 0 2100 9999100 10 1 10010010110110099 98 PROP. FENCE (TYP.) P/LP/ L P/L with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:06 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 41CG-141 1" = 40' 237 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-128 MATCH LINE SEE DRAWING NO. CG-141MATCH LINESEE DRAWING NO. CG-144 MATCH LINE 3 + 0 0 4 + 0 0 5 +00 6+00 PROP. TERMINAL DRIVE 3863-71-6244 CSX TRANSPORTATION, INC. 3863-84-9571 EDGECOMBE GENCO LLC EX. EDGE OF GRAVEL (TRM) EX. BUILDING (TRM) FINAL ID 148 EX. ESA WELL EX. POWER POLE (TRM) EX. OVERHEAD ELEC. (TRM) EX. OVERHEAD ELEC. (TRM) EX. 27" SAN. (TRM) (PLAN) EX. SIGN (TRM) EX. STM. CULVERT (TRM)P/LP/LP/LEX. GRAVEL (TRM) EX. 30' PERMANENT EASEMENT (PLAN) EX. OVERHEAD ELEC. (TRM) INV.(E)=79.50 INV.(W)=79.54 EX. SAN. MH (TRM) (PLAN) INV.(E)=79.76 INV.(W)=79.81 EX. SAN. MH (TRM) (PLAN) DITCH (TRM) EX. C/L (BY OTHERS) PROP. GAS MAIN PROP. GAS MAIN (BY OTHERS) EX. C/L DITCH (TRM) (BY OTHERS) PROP. GAS MAIN EX. BUILDING (TRM) LIMITS OF 100 YEAR FLOOD HAZARD LIMITS OF FLOOD HAZARD LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF 100 YEAR FLOOD HAZARD EX. WETLAND (TRM)EX. WETLAND (TRM) LIMITS OF FLOOD HAZARD (TRM) (PLAN) EX. 27" SAN. LIMITS OF FLOOD HAZARD EX. STREAM (TRM) EX. GRAVEL (TRM) EX. STREAM BUFFER EX. GRAVEL (TRM) LIMITS OF FLOOD HAZARD EX. STREAM BUFFER EX. C/L DITCH (TRM)LIMITS OF 500 YEAR FLOOD HAZARD LIMITS OF 100 YEAR FLOOD HAZARD EX. 27" SAN. (TRM) (PLAN) EX. WETLAND (TRM) LIMITS OF FLOOD HAZARD EX. STREAM BUFFER EX. STM. CULVERT (TRM) EX. STREAM (TRM) EX. 27" SAN. (TRM) (PLAN) LIMITS OF FLOOD HAZARD HW34 9 8 9 8 9 89795959 5 92 9394 969 7 919090 9 0 90908888 8 8 89878 7 878787 8 7 8 6 8 5 848586 96 86868 6 86 8685 85878885 85 85 85 85 86 87 9697 97 98 98 99 9995 9693 949295 1 0 0 93 9 4 9 6 9798 9 9 101100969594 919293 9087 888991 8 7 8889 8788898788 8990888 9 8988 9 0 878 889 9186868686868585868486PROP. C/L DITCH DITCH PROP. C/L 98 99 PROP. LIGHT POLE (TYP.) 1 0 0 10010 0 9 8 9 8 1 0 0 1 0 0 96 99 9 7 97 (TYP.) FENCE PROP. P/ L INV=97.00 P R O P. 2 4" ST M. PROP. LEVEL SPREADER (E) with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/28/20191:19:25 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 42CG-142 1" = 40' 238 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-144MATCH LINESEE DRAWING NO. CG-141 MATCH LINE 3863-71-6244 CSX TRANSPORTATION, INC. 3873-00-4906 BRUCE LEA FLYE ET AL OLD BATTLEBORO RD EX. POW ER POLE (TRM) P/L EX. GRAVEL (TRM) EX. C/L DITCH (TRM) EX. C/L DITCH (TRM)EX. OVERHEAD ELEC. (TRM) P/L P/LEX. OVERHEAD ELEC. (TRM) EX. ASPHALT PAVEMENT (TRM) EX. STM. CULVERT (TRM) EX. STM. CULVERT (TRM) EX. C/L DITCH (TRM) EX. POW ER POLE (TRM) EX. C/L DITCH (TRM) EX. NATURAL GAS LINE (TRM) EX. SIGN (TRM) EX. C/L DITCH (TRM) EX. W AT. MARKER (TRM) EX. 24" W AT. MAIN (TRM) (PLAN) EX. OVERHEAD ELEC. (TRM) P/L EX. POW ER POLE (TRM) EX. OVERHEAD ELEC. (TRM) EX. GRAVEL (TRM) EX. C/L DITCH (TRM) EX. POWER POLE (TRM)1001051011021031041061071081 0 9 1 0 9 110111112113114 1131141 1 0 1091111121081001059899101102103104106107 112113114 110108109111107105 103104 106105 100 100105 11099 101102103104106107108 109110 110 105 100 100 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:08 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 43CG-143 1" = 40' 239 0 40'80'20'40' GRAPHIC SCALE:1" = 40'NO WORK THIS SHEET JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 115A VAL 6060+13 113 A EMT1 5954+92EMT1 6008+14114 A SEE DRAWING NO. CG-142 MATCH LINE SEE DRAWING NO. CG-143MATCH LINE0+001+002+00PROP. TERMINAL DRIVE PROP. 24" STM. 3863-71-6244 CSX TRANSPORTATION, INC. 3873-00-4906 BRUCE LEA FLYE ET AL OLD BATTLEBORO RD EX. POWER POLE (TRM) EX. OVERHEAD ELEC. (TRM) ELEC. (TRM)EX. OVERHEAD EX. 30" SAN. (TRM) (PLAN)EX. 2 7 " SAN. (T RM) (PL AN) INV.(E)=79.85 INV.(W)=78.91 EX. SAN. MH (TRM) (PLAN) EX. FH (TRM) EX. SAN. STEEL ENCASEMENT (TRM) (PLAN) ELEC. (TRM) EX. OVERHEAD EX. SIGN (TRM) (BY OTHERS) PROP. GAS MAIN PROP. GAS MAIN (BY OTHERS) P/L P/L EX. GRAVEL (TRM) EX. 24" WAT. MAIN (TRM) (PLAN)EX. C/L DITCH (TRM) EX. NATURAL GAS LINE (TRM) EX. C/L DITCH (TRM) P/L EX. ASPHALT PAVEMENT (TRM) P/L EX. POWER POLE (TRM) EX. GUY WIRE (TRM) EX. OVERHEAD ELEC. (TRM) P/L EX. NATURAL GAS LINE (TRM) EX. C/L DITCH (TRM) INV.(E)=79.05 INV.(W)=79.11 EX. SAN. MH (TRM) (PLAN) EX. 27" SAN. (TRM) (PLAN)INV.(E)=79.29 INV.(W)=79.35 EX. SAN. MH (TRM) (PLAN) (BY OTHERS) PROP. GAS MAIN PROP. GAS MAIN (BY OTHERS) EX. 24" WAT. MAIN (TRM) (PLAN) EX. GRAVEL (TRM) LIMITS OF FLOOD HAZARD LIMITS OF FLOOD HAZARD LIMITS OF 100 YEAR FLOOD HAZARDLIMITS OF 500 YEAR FLOOD HAZARD FLOOD HAZARD LIMITS OF LIMITS OF 100 YEAR FLOOD HAZARD EX. C/L DITCH (TRM) LIMITS OF 100 YEAR FLOOD HAZARD EX. CONCRETE PAVEMENT (TRM) EX. C/L DITCH (TRM) LIMITS OF 500 YEAR FLOOD HAZARD EX. GRAVEL (TRM) FLOOD HAZARD LIMITS OF 500 YEAR EX. OVERHEAD ELEC. (TRM) LIMITS OF FLOOD HAZARD EX. POWER POLE (TRM) EX. STREAM BUFFER EX. 30' PERMANENT EASEMENT (PLAN) EX. WETLAND (TRM)EX. WETLAND (TRM) FLOOD HAZARD LIMITS OF 100 YEAR EX. 27" SAN. (TRM) (PLAN) LIMITS OF FLOOD HAZARD EX. STREAM BUFFER LIMITS OF FLOOD HAZARD EX. STREAM (TRM) 3863-84-9571 EDGECOMBE GENCO LLC LIMITS OF FLOOD HAZARD (BY OTHERS) PROP. GAS MAIN989896979 7 9 796 95 92 929394 969798 100 8584 8 485 97 98 99 9899 96979594 9087888991929387888 6868686878895 90 90 909090909 0 90 90 87 87 86 87 85 858684 8 58788 89 84858790 92 90 86 879090878889DITCH PROP. C/L PROP. C/L DITCH INV=93.54 HW37 HW36 9 9 99 9 8 9 7 9 7 9 8 9 9 95POLE (TYP.) PROP. LIGHT EX. STM. (TRM) (TYP.) FENCE PROP. P/ L PROP. MONUMENT SIGN INV=92.62 PROP. FENCE (TYP.) 9 7 9 6 95949 5 9 5 9 6 9 7 9493 9394 96 959597 9796 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT- - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:10 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-101-144.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROPOSED WATER LINE PROPOSED FENCE EXISTING PAVEMENT PROPOSED PAVEMENT PROPOSED GRAVEL CATCH BASIN EXISTING BOLLARD EXISTING WATER VALVE EXISTING GUY WIRE EXISTING WETLAND LEGEND PROPOSED C/L OF TRACK SWITCH STAND/MACHINE IS ON) -POINT OF SWITCH (DENOTES SIDE PROPOSED STORM SEWER EXISTING ELECTRIC PULLBOX EXISTING ELECTRIC METER EXISTING COMMUNICATION PEDESTAL EXISTING UTILITY MARKER EXISTING LIGHT POLE EXISTING POWER POLE HYDRANT EXISTING SIGN EXISTING SETBACK EXISTING RIGHT-OF-WAY PROJECT BOUNDARY EXISTING PROPERTY LINE EASEMENT/BUFFER EXISTING C/L OF TRACK MANHOLE EXISTING C/L OF DITCH EXISTING C/L OF PAVEMENT EXISTING FENCE EXISTING OVERHEAD ELECTRIC EXISTING EDGE OF GRAVEL EXISTING OVERHEAD COMMUNICATIONS LINE EXISTING EDGE OF PAVEMENT/CURB EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING NATURAL GAS LINE EXISTING WATER MAIN EXISTING COMMUNICATIONS LINE EXISTING UNDERGROUND ELECTRIC EXISTING FIBER OPTIC LINE PROPOSED WATER SERVICE PROPOSED ORNAMENTAL FENCE PROPOSED NATURAL GAS LINE PROPOSED COMPRESSED AIR LINE PROPOSED FIRE LINE PROPOSED SANITARY SERVICE PROPOSED SANITARY SEWER MANHOLE VALVE AIR OUTLET PROPOSED BOLLARD PROPOSED GATE HYDRANT PROPOSED UNDERDRAIN CLEANOUT XXX EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR109 110 PROPOSED C/L DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR109 110 EXISTING 500 YR FLOODPLAIN EXISTING 100 YR FLOODPLAIN PROPOSED ROADWAY LIGHT POLE PROPOSED HIGH MAST LIGHT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 28 42 4443 NOTES 5. SEE DRAWING NO. CG-201 TO CG-204 FOR GRADING DETAILS. 4. SEE DRAWING NO. CG-145 TO CG-159 FOR STORM PROFILES. PROPOSED SUBGRADE. 3. PROPOSED CONTOURS IN TRACK AREAS ARE BASED UPON TOP OF BASED UPON PROPOSED FINISHED GRADE. 2. PROPOSED CONTOURS AND GRADES IN PAVEMENT AREAS ARE T/O AND FOLLOWS ST07 THROUGH THE PROCESS AREA. 1. THE BASELINE ALIGNMENT SHOWN IS FROM NO. 15 T/O TO NO. 15 GRADING & DRAINAGE PLAN - ZONE 44CG-144 1" = 40' 240 0 40'80'20'40' GRAPHIC SCALE:1" = 40' JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:11 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PROP. SUBBALLAST PROP. GRADE EX. GROUND 349.55 L.F. 48" @ 0.20% 120.62 120.69 120.72 120.55 CONCRETE ENDWALLNCDOT STD. DWG. 838.01STA. 3+49.55NCDOT STD. DWG. 838.01CONCRETE ENDWALLSTA. 0+00.00HW2HW1 110 120 130 140 150 STATION EX GROUND INVERT CUT 118.17 118.37 118.57 118.77 2.45 2.32 2.15 1.79118.17118.860 1 2 3 110 120 130 140 150 PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND HW4 CONCRETE ENDWALLNCDOT STD. DWG. 838.01STA. 7+77.00PROP. GRADE EX. GROUND 113.89777.00 L.F. 48"(2) @ 0.20% 119.04120.93123.06122.75121.91121.45119.98 112.73112.93113.13113.33113.53 6.308.009.939.428.38 110 120 130 140 150 STATION EX GROUND INVERT CUT 2345678 113.73 7.72 110 120 130 140 150 STORM SEWER PROFILES 241 CG-145 MATCH LINESEE DRAWING CG-146 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:12 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWINGSTA. 0+12.28CATCH BASIN3.323.27-0.23 92.8493.2993.64 96.1796.5793.41 INV.=93.89 STM. (SW) PROP. 24"92.9992.8492.8993.6436" @ 0.35% 12.29 L.F.36" @ 0.35% 187.71 L.F. EX. GROUND PROP. GRADE 80 90 100 110 120 80 90 100 110 120 STATION EX GROUND INVERT CUT RIM=98.0788 HW5HW6 012 PRECAST 36" CONCRETEHALF-HEIGHT HEADWALLSTA. 0+00.00PRECAST 36" CONCRETEHALF-HEIGHT HEADWALLSTA. 2+00.00PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND EX. GROUND PROP. GRADE 3.49 96.22 99.7096.2296.9436" @ 0.93% 77.24 L.F. 80 90 100 110 120 80 90 100 110 120 STATION EX GROUND INVERT CUT HW7HW8 01PRECAST 36" CONCRETEHALF-HEIGHT HEADWALLSTA. 0+61.00PRECAST 36" CONCRETEHALF-HEIGHT HEADWALLSTA. -0+00.0098.7098.4612" @ 0.48% 49.81 L.F. EX. GROUND PROP. GRADE 0.28 98.46 98.74 80 90 100 110 120 80 90 100 110 120 STATION EX GROUND INVERT CUT OUTLET STRUCTURESTA. 0+49.81RIM=101.500 1PRECAST 12" CONCRETEHALF-HEIGHT HEADWALLSTA. -0+00.00HW9 1 CONCRETE ENDWALLNCDOT STD. DWG. 838.01STA. 0+00.00112.33115.79118.41119.04 112.33112.53112.73 3.465.876.30 110 120 130 140 150 012 HW3 48"(2) @ 0.20% 777.00 L.F. EX. GROUND PROP. GRADE 110 120 130 140 150 STATION EX GROUND INVERT CUT STORM SEWER PROFILES 242 CG-146SEE DRAWING CG-145MATCH LINE JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:13 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND 110 120 130 140 150 110 120 130 140 150 STATION EX GROUND INVERT CUT 0 1 127.99 127.67 118.02 9.96 PROP. GRADE RIM=121.87PRECAST 18" CONCRETEHALF-HEIGHT HEADWALLSTA. -0+00.00PROPOSED CATCH BASINSTA. 0+26.50BULKHEADSTA. 1+06.50118.02118.20118.10118.3626.50 L.F. 18" @ 0.30% 80.00 L.F. 18" @ 0.20% 4 EX. GROUND BH1HW11 118.35117.87118.42118.25EX. GROUND PROP. GRADE 30" @ 0.50% 15.00 L.F. 30" @ 0.50% 76.00 L.F. 6.44 117.87 126.20 125.98 0 1 110 120 130 140 150 110 120 130 140 150 STATION EX GROUND INVERT CUT BH3BH2 RIM=123.695 PROPOSED MANHOLESTA. 0+76.00BULKHEADSTA. -0+00.00BULKHEADSTA. 0+91.00119.75119.27119.82119.6530" @ 0.50% 15.00 L.F.30" @ 0.50% 76.00 L.F. EX. GROUND PROP. GRADE 6.23 119.26 125.78 126.69 0 1 100 110 120 130 140 100 110 120 130 140 STATION EX GROUND INVERT CUT BULKHEADSTA. 0+91.00PROPOSED MANHOLESTA. 0+76.00BULKHEADSTA. -0+00.00RIM=125.206 BH5BH4 PROP. SUBBALLAST 97.5097.7542" @ 0.50% 50.00 L.F. EX. GROUND PROP. GRADE 97.8598.2036" @ 0.50% 69.05 L.F. 4.97 5.76 97.50 98.10 102.47 103.86 80 90 100 110 120 80 90 100 110 120 STATION EX GROUND INVERT CUT RIM=103.33RIM=102.600 1 PROPOSED CATCH BASINW/ 3'x1' WINDOW, ALL SIDESSTA. 1+19.05PROPOSED CATCH BASINW/ 3'x1' WINDOW, ALL SIDESSTA. 0+50.00PRECAST 42" CONCRETEHALF-HEIGHT HEADWALLSTA. 0+00.00HW10 2 3 WINDOW ELEV. = 101.83WINDOW ELEV. = 101.10STORM SEWER PROFILES 243 CG-147 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:13 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND PROP. GRADE INV.=113.79 STM. (N) PROP. 36" INV.=113.89 STM. (S) PROP. 36"114.56114.5018" @ 0.50% 11.95 L.F. EX. GROUND 3.65 114.50 118.15 100 110 120 130 140 100 110 120 130 140 STATION EX GROUND INVERT CUT RIM=118.007 HW12 DIVERSION STRUCTURESTA. 0+06.54CONNECT TO LEVEL SPREADERSTA. 0+00.000 INV.=114.56 STM. (NE) PROP. 18" 36" @ 0.20% 20.00 L.F.36" @ 0.20% 30.81 L.F.113.79113.95113.75113.89EX. GROUND PROP. GRADE 3.91 113.75 117.66 100 110 120 130 140 100 110 120 130 140 STATION EX GROUND INVERT CUT 36" FLARED END SECTIONSTA. 0+00.00DIVERSION STRUCTURESTA. 0+20.00OUTLET STRUCTURESTA. 0+50.81HW13 RIM=118.007 RIM=119.008 01 36" @ 0.30% 93.35 L.F. PROP. GRADE INV.=126.32 PROP. 12" STM. (SW) INV.=125.83 PROP. 18" STM. (NE)117.44116.35114.54117.04115.9542" @ 0.30% 229.57 L.F. 48" @ 0.55% 255.56 L.F. EX. GROUND PROP. GRADE 8.22 7.39 5.73 5.95 6.69 5.06 114.54 115.09 115.64 116.48 116.78 117.48 122.76 122.48 121.37 122.44 123.47 122.54 110 120 130 140 150 STATION EX GROUND INVERT CUT CATCH BASINSTA. 4+85.13CATCH BASINSTA. 2+55.56RIM=128.90RIM=122.090 1 2 3 4 5PRECAST 48" CONCRETEHALF-HEIGHT HEADWALLSTA. -0+00.001211HW14 110 120 130 140 150 STORM SEWER PROFILES 244 CG-148 MATCH LINESEE DRAWING CG-149 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 INV.=117.44 PROP. 36" STM. (NW) INV.=117.04 PROP. 42" STM. (SE) INV.=125.83 STM. (NE) PROP. 18" 18" @ 0.20% SLOTTED DRAIN 153.29 L.F.125.83126.14EX. GROUND PROP. GRADE -2.45-2.91 125.83126.03 123.38123.12 110 120 130 140 150 110 120 130 140 150 STATION EX GROUND INVERT CUT CATCH BASINSTA. 0+00.00CATCH BASINSTA. 1+53.29012RIM=128.9012 RIM=128.9026 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:14 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND 110 120 130 140 150 PROP. GRADE PROP. GRUNT LANE PROP. SUBBALLAST INV.=121.13 STM. (NE) PROP. 12" INV.=119.99 STM. (SW) PROP. 18" INV.=120.75 PROP. 15" STM. (SW) INV.=120.35 PROP. 15" STM. (NE)118.75118.39117.82118.65119.07117.99117.7230" @ 0.50% 63.50 L.F. 30" @ 0.50% 52.00 L.F.36" @ 0.30% 58.00 L.F. 36" @ 0.30% 93.35 L.F. 5.06 6.13 6.09 117.48 117.88 118.81 122.54 124.02 124.89 110 120 130 140 CATCH BASINSTA. 6+88.47CATCH BASINSTA. 6+36.47CATCH BASINSTA. 5+78.47RIM=127.33RIM=127.78RIM=128.675 6 7 CONCRETE ENDWALLNCDOT STD. DWG. 838.01STA. 7+51.97150HW15151413 EX. GROUND INV.=117.44 PROP. 36" STM. (NW) INV.=117.04 PROP. 42" STM. (SW) INV.=126.32 STM. (SW) PROP. 12"125.8318" @ 0.20% SLOTTED DRAIN 300.00 L.F. EX. GROUND PROP. GRADE -2.45 -2.13 -1.35 125.83 126.03 126.23 123.38 123.90 124.88 110 120 130 140 150 STATION EX GROUND INVERT CUT CATCH BASINSTA. -0+00.00RIM=128.900 1 2 12 110 120 130 140 150 STORM SEWER PROFILES 245 CG-149MATCH LINESEE DRAWING CG-148SEE DRAWING CG-150MATCH LINE JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:15 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND 110 120 130 140 150 18" @ 0.20% SLOTTED DRAIN 300.00 L.F. INV.=126.98 PROP. 18" STM. (NE)126.53126.43126.9818" @ 0.15% SLOTTED DRAIN 300.00 L.F. -1.35 -0.58 0.26 1.61 126.23 126.48 126.68 126.83 124.88 125.90 126.94 128.44 128.96 110 120 130 140 150 RIM=128.90CATCH BASINSTA. 6+00.00CATCH BASINSTA. 3+00.00RIM=128.902 3 4 5 6 27 28 EX. GROUND PROP. GRADE 36" @ 0.30% 93.35 L.F. INV.=125.83 (NE &SW) PROP. 18" STM.114.85116.45117.54117.14116.0542" @ 0.30% 229.57 L.F. 48" @ 0.47% 255.56 L.F. EX. GROUND PROP. GRADE 10.38 10.82 10.49 9.82 10.13 9.26 114.85 115.32 115.79 116.58 116.89 117.58 125.22 126.14 126.28 126.40 127.02 126.84 100 110 120 130 140 STATION EX GROUND INVERT CUT RIM=128.9017 RIM=122.0916HW16 CATCH BASINSTA. 4+85.13CATCH BASINSTA. 2+55.560 1 2 3 4 5PRECAST 48" CONCRETEHALF-HEIGHT HEADWALLSTA. 0+00.00100 110 120 130 140 STORM SEWER PROFILES 246 CG-150MATCH LINESEE DRAWING CG-149MATCH LINESEE DRAWING CG-151 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:16 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND 100 110 120 130 140 EX. GROUND PROP. GRADE PROP. GRUNT LANE SUBBALLAST PROP. INV.=120.10 (NE & SW) PROP. 18" STM. INV.=120.48 (NE & SW) PROP. 12" STM. INV.=120.40 (NE & SW) PROP. 15" STM.117.92118.19118.75119.06118.35118.09117.8230" @ 0.50% 63.50 L.F. 36" @ 0.30% 52.00 L.F. 36" @ 0.30% 58.00 L.F. 36" @ 0.30% 93.35 L.F. 9.26 8.12 7.09 117.58 117.98 118.80 126.84 126.10 125.89 100 110 120 130 140 RIM=127.3420 RIM=127.7819 RIM=128.6718 CATCH BASINSTA. 6+88.48CATCH BASINSTA. 6+36.47CATCH BASINSTA. 5+78.485 6 7 NCDOT STD. DWG. 838.01CONCRETE ENDWALLSTA. 7+51.97HW17 INV.=125.87 PROP. 18" STM. (NE) INV.=117.15 PROP. 42" STM. (SE) INV.=117.54 PROP. 36" STM. (NW) INV.=126.98 PROP. 18" STM. (SW) 18" @ 0.15% SLOTTED DRAIN 300.00 L.F. 18" @ 0.20% SLOTTED DRAIN 300.00 L.F.126.53125.83126.43126.98PROP. GRADE EX. GROUND 1.120.38-0.040.621.061.81 125.83126.03126.23126.43126.68126.83 126.95126.41126.19127.05127.74128.64128.96 110 120 130 140 150 110 120 130 140 150 STATION EX GROUND INVERT CUT CATCH BASINSTA. 0+00.00CATCH BASINSTA. 3+00.00CATCH BASINSTA. 6+00.00RIM=128.90RIM=128.90RIM=128.900123456 174428 STORM SEWER PROFILES 247 CG-151MATCH LINESEE DRAWING CG-150 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:17 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND PROP. GRADE EX. GROUND 0 1 2 3 4 5 6 PROP. 18" STM. (NE) INV.=126.98 PROP. 42" STM. (SW) INV.=117.15 PROP. 36" STM. (NE) INV.=117.54 PROP. 18" STM. (SW) INV.=125.83 300.00 L.F. 18" @ 0.15%300.00 L.F. 18" @ 0.20%126.43126.98126.53125.831.12 0.44 0.54 0.61 0.70 -0.18 125.83 126.03 126.23 126.43 126.68 126.83 126.95 126.47 126.77 127.04 127.38 126.65 124.70RIM=128.90RIM=128.90RIM=128.90CATCH BASINSTA. 6+00.00CATCH BASINSTA. 3+00.00CATCH BASINSTA. -0+00.00110 120 130 140 150 110 120 130 140 150 STATION EX GROUND INVERT CUT 17 45 46 INV.=112.93 PROP. 24" STM. (S) 24" @ 0.20% 61.68 L.F. 12" @ 0.50% 6.70 L.F.113.03114.15113.15114.18EX. GROUND PROP. GRADE 2.90 114.15 117.05 100 110 120 130 140 100 110 120 130 140 STATION EX GROUND INVERT CUT OUTLET STRUCTURESTA. 0+68.38DIVERSION STRUCTURESTA. 0+06.7012" FLARED END SECTIONSTA. -0+00.00RIM=120.5010 RIM=115.959 HW18 0 1 STORM SEWER PROFILES 248 CG-152 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:17 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND INV.=114.18 PROP. 12" STM. (W) INV.=113.03 PROP. 24" STM. (NE) 24" @ 0.20% 10.00 L.F.112.91112.93EX. GROUND PROP. GRADE 0.00 112.91 112.91 100 110 120 130 140 100 110 120 130 140 STATION EX GROUND INVERT CUT RIM=115.959 HW19 DIVERSION STRUCTURESTA. 0+10.0024" FLARED END SECTIONSTA. -0+00.000 INV.=120.48 (NE & SW) PROP. 12" STM. PROP. GRUNT LANE PROP. SUBBALLAST INV.=120.10 (NE & SW) PROP. 15" STM. INV.=120.40 (NE & SW) PROP. 12" STM. INV.=125.83 (NE & SW) PROP. 18" STM.114.94116.36117.45117.83118.40118.76119.27118.66118.00117.73117.05115.9630" @ 0.50% 101.00 L.F. 30" @ 0.50% 52.00 L.F.36" @ 0.30% 58.00 L.F. 36" @ 0.30% 93.32 L.F. 42" @ 0.30% 229.60 L.F. 48" @ 0.40% 255.56 L.F. PROP. GRADE PROP. GRADE EX. GROUND 6.03 4.80 5.84 7.90 9.10 9.13 9.29 8.63 114.95 115.34 115.74 116.49 116.79 117.49 117.89 118.82 120.98 120.14 121.58 124.39 125.89 126.62 127.19 127.44 127.25 100 110 120 130 140 100 110 120 130 140 STATION EX GROUND INVERT CUT CATCH BASINSTA. 2+55.56CATCH BASINSTA. 4+85.15CATCH BASINSTA. 5+78.48CATCH BASINSTA. 6+36.47CATCH BASINSTA. 6+88.48HW21 RIM=126.8425 RIM=126.7124 RIM=126.8423 RIM=128.9022 RIM=122.0921HW20 0 1 2 3 4 5 6 7 8CONCRETE ENDWALLNCDOT STD. DWG. 838.01STA. 7+89.47PRECAST 48" CONCRETEHALF-HEIGHT HEADWALLSTA. -0+00.00STORM SEWER PROFILES 249 CG-153 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:18 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND INV.=125.83 PROP. 18" STM. (NW) INV.=117.05 PROP. 42" STM. (SE) INV.=117.45 PROP. 36" STM. (NW) INV.=127.02 PROP. 18" STM. (SW) 18" @ 0.20% SLOTTED DRAIN 300.00 L.F. 18" @ 0.15% SLOTTED DRAIN 300.00 L.F.126.98126.43125.83126.53EX. GROUND PROP. GRADE 0.640.44-0.74-3.74-8.60-5.90-2.28 125.83126.03126.23126.43126.68126.83126.98 126.47126.47125.49122.69118.08120.93124.70 100 110 120 130 140 100 110 120 130 140 STATION EX GROUND INVERT CUT RIM=128.9022 RIM=128.9056 RIM=128.9046 CATCH BASINSTA. 6+00.00CATCH BASINSTA. 3+00.00CATCH BASINSTA. -0+00.000123456 INV.=117.05 PROP. 42" STM. (SE) INV.=117.45 PROP. 36" STM. (NW) INV.=125.87 PROP. 18" STM. (SW)125.8318" @ 0.24% SLOTTED DRAIN 300.00 L.F. EX. GROUND PROP. GRADE 0.64 0.66 0.50 125.83 126.07 126.32 126.47 126.73 126.81 100 110 120 130 140 STATION EX GROUND INVERT CUT RIM=128.9022 CATCH BASINSTA. 0+00.000 1 2 100 110 120 130 140 STORM SEWER PROFILES 250 CG-154 SEE DRAWING CG-155MATCH LINE JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:19 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND 100 110 120 130 140 EX. GROUND PROP. GRADE 126.66126.56126.9818" @ 0.24% SLOTTED DRAIN 131.71 L.F. 0.50 -0.87 -1.93 126.32 126.56 126.91 126.81 125.69 124.99 100 110 120 130 140 RIM=128.9058 RIM=128.9057 CATCH BASINSTA. 4+31.71CATCH BASINSTA. 3+00.002 3 4 5 36" @ 0.50% 116.34 L.F.115.68116.27INV.=119.68 PROP. 24" STM. (W)116.27116.75117.69118.64119.25118.24117.29116.6524" @ 0.50% 121.30 L.F. 30" @ 0.50% 109.27 L.F. 36" @ 0.30% 179.81 L.F. 36" @ 0.50% 76.66 L.F. EX. GROUND PROP. GRADE 9.69 9.53 9.81 8.55 5.01 2.05 116.18 116.77 117.07 117.83 118.73 119.23 125.26 125.87 126.30 126.88 126.38 123.74 121.28 100 110 120 130 140 100 110 120 130 140 STATION EX GROUND INVERT CUT RIM=130.10OWS 1 OIL-WATER SEPARATORSTA. 1+16.34RIM=123.5071 RIM=127.7470 RIM=127.9169 RIM=129.3968HW22 CATCH BASINSTA. 6+03.37CATCH BASINSTA. 4+82.08CATCH BASINSTA. 3+72.81CATCH BASINSTA. 1+93.000 1 2 3 4 5 6PRECAST 36" CONCRETEHALF-HEIGHT HEADWALLSTA. 0+00.00STORM SEWER PROFILES 251 CG-155SEE DRAWING CG-154MATCH LINE JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:20 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND INV.=118.24 PROP. 30" STM. (SW) INV.=118.64 PROP. 24" STM. (NE)24" @ 0.50% 202.92 L.F.120.69119.68EX. GROUND PROP. GRADE 4.946.816.13 119.68120.18120.68 124.62126.99126.81 100 110 120 130 140 100 110 120 130 140 STATION EX GROUND INVERT CUT CATCH BASINSTA. 0+00.00CATCH BASINSTA. 2+02.92RIM=127.7470 RIM=125.4472 012 INV.=122.33 PROP. 10" UD (NE) INV.=122.66 PROP. 8" UD (SW) PROP. SUBBALLAST 119.87 126.92 126.46 127.28 6.59 INV.=121.52 PROP. 6" UD (NE) INV.=122.51 PROP. 8" UD (SW) 24" @ 0.50% 83.39 L.F. 24" @ 0.50% 179.71 L.F.119.37120.37120.79120.27EX. GROUND PROP. GRADE 100 110 120 130 140 100 110 120 130 140 STATION EX GROUND INVERT CUT HW23 CATCH BASINSTA. 2+63.10CATCH BASINSTA. 1+79.71RIM=125.3374 RIM=125.1773 0 1 2 3PRECAST 24" CONCRETEHALF-HEIGHT HEADWALLSTA. 0+00.00119.37 7.55 120.47 6.81 PROP. SUBBALLAST 114.25 INV.=116.74 PROP. 10" UD (S) 18" @ 0.50% 60.81 L.F.116.34116.64EX. GROUND PROP. GRADE 100 110 120 130 140 100 110 120 130 140 STATION EX GROUND INVERT CUT RIM=119.6777HW24 CATCH BASINSTA. 0+60.810 1PRECAST 18" CONCRETEHALF-HEIGHT HEADWALLSTA. 0+00.00PROP. SUBBALLAST 109.86 112.46115.54 109.86110.2636" @ 0.50% 80.46 L.F. EX. GROUND PROP. GRADE 2.60 HW25 RIM=115.3978 100 110 120 130 140 100 110 120 130 140 STATION EX GROUND INVERT CUT 01 PRECAST 36" CONCRETEHALF-HEIGHT HEADWALLSTA. 0+00.00PROPOSED CATCH BASINW/ 3'x1' WINDOW, ALL SIDESSTA. 0+80.46STORM SEWER PROFILES 252 CG-156 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:20 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND 118.56116.92111.95117.42115.40111.6624" @ 0.50% 227.71 L.F. 30" @ 0.50% 303.45 L.F. 30" @ 0.50% 57.40 L.F. EX. GROUND PROP. GRADE 9.01 11.35 12.98 14.23 13.81 13.25 111.66 112.26 112.76 113.26 113.87 114.37 120.67 123.61 125.74 127.50 127.68 127.62 0 1 2 3 4 5 6 100 110 120 130 140 100 110 120 130 140 STATION EX GROUND INVERT CUT HW26 RIM=123.3181 RIM=123.8780 RIM=120.3879 CATCH BASINSTA. 5+88.55CATCH BASINSTA. 3+60.8530" FLARED END SECTIONSTA. 0+00.00CATCH BASINSTA. 0+57.40105.15110.6736" @ 2.00% 176.95 L.F. PROP. GRADE 5.746.155.90 105.15107.35109.35 100 110 120 130 140 100 110 120 130 140 STATION EX GROUND INVERT CUT HW27HW28 012 PRECAST 36" CONCRETEHALF-HEIGHT HEADWALLSTA. 0+00.00PRECAST 36" CONCRETEHALF-HEIGHT HEADWALLSTA. 2+65.803 STA. 0+88.86PROPOSED CATCH BASINW/ 3'x1' WINDOW, ALL SIDESWINDOW ELEV. = 111.4791 RIM=112.97EX. GROUND 36" @ 2.00% 88.86 L.F.107.13106.93115.26 113.50 110.90 STORM SEWER PROFILES 253 CG-157 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:21 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND 96.93 99.45 12" @ 0.20% 43.52 L.F.97.0296.93EX. GROUND PROP. GRADE 2.52 90 100 110 120 130 90 100 110 120 130 STATION EX GROUND INVERT CUT RIM=102.3190 HW33 OUTLET STRUCTURESTA. 0+43.5212" FLARED END SECTIONSTA. -0+00.0001 93.8994.89 96.43102.98 INV=92.99 STM. (S) PROP. 36" INV.=92.89 STM. (N) PROP. 36" 24" @ 1.00% 129.73 L.F.95.1893.89EX. GROUND PROP. GRADE 2.548.10 90 100 110 120 130 90 100 110 120 130 STATION EX GROUND INVERT CUT RIM=102.3189 RIM=98.0788 RIM=98.0788 OUTLET STRUCTURESTA. 1+29.73CATCH BASINSTA. 0+00.0001 112.6824" @ 1.50% 300.00 L.F. 109.90111.40 112.16114.09 2.262.69 90 100 110 120 130 STATION EX GROUND INVERT CUT RIM=116.9385 CATCH BASINSTA. 7+85.64678 EX. GROUND PROP. GRADE 90 100 110 120 130 36" @ 2.50% 51.60 L.F.97.3098.596.95 97.30 104.25 0 1 80 90 100 110 120 80 90 100 110 120 STATION EX GROUND INVERT CUT HW30HW29 PRECAST 36" CONCRETEHALF-HEIGHT HEADWALLSTA. 0+00.00PROP. GRADE EX. GROUND PRECAST 36" CONCRETEHALF-HEIGHT HEADWALLSTA. 0+51.60STORM SEWER PROFILES 254 CG-158 SEE DRAWING CG-159MATCH LINE JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:22 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-145-159.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING PIPE & BEDDING/BACKFILL NOTES 0 5'10'2.5'5' GRAPHIC SCALE:1" = 5' 0 40'80'20'40' GRAPHIC SCALE:1" = 40' HORIZONTAL VERTICAL CAROLINA DEPARTMENT OF TRANSPORTATION CONSTRUCTION SPECIFICATIONS. FROM THE EDGE OF PAVEMENT OR 12' FROM THE C/L OF THE TRACK. ALL MATERIALS SHALL CONFORM TO THE NORTH GRANULAR MATERIAL TO THE LIMIT OF INFLUENCE OF THE PAVEMENT OR TRACK. LIMIT OF INFLUENCE IS A 1:1 SLOPE ALL PIPES WITHIN THE INFLUENCE OF PAVEMENT OR TRACK OR FUTURE PAVEMENT OR TRACK SHALL BE BACKFILLED WITH TOP OF PIPE). FILL IN ACCORDANCE WITH PROJECT SPECIFICATIONS PRIOR TO CONSTRUCTION OF THE STORM SEWER (MIN. 24" ABOVE IN LOCATIONS WHERE THE EXISTING GROUND IS BELOW THE PROPOSED PIPE ELEVATION, THE CONTRACTOR SHALL PLACE ALL PIPE SHALL BE REINFORCED CONCRETE, CLASS V UNLESS OTHERWISE NOTED. WATERTIGHT SEAL. LOCAL JURISDICTIONS STANDARDS. ALL STRUCTURES ASSOCIATED WITH THESE PIPE RUNS SHALL BE PROVIDED WITH A ALL PIPE RUNS ARE TO HAVE WATERTIGHT JOINTS AND MATERIAL SPECIFICATIONS IN ACCORDANCE WITH THIS PLAN AND 90 100 110 120 130 STATION EX GROUND INVERT CUT EX. GROUND PROP. GRADE 103.92108.18108.0824" @ 1.39% 300.00 L.F. 97.3099.65104.12105.51106.89108.40109.90 104.98106.38107.67108.56109.55110.58112.16 36" @ 0.50% 103.62 L.F. 36" @ 0.50% 82.03 L.F.97.71100.0897.3099.56EX. GROUND PROP. GRADE 7.686.723.563.062.652.182.26 90 100 110 120 130 RIM=112.4384 CATCH BASINSTA. 4+85.64HW31 RIM=106.4082 RIM=108.1783 CATCH BASINSTA. 1+85.640123456 PRECAST 36" CONCRETEHALF-HEIGHT HEADWALLSTA. 0+00.00PROPOSED CATCH BASINW/ 3'x1' WINDOW, ALL SIDESSTA. 0+82.0324" @ 1.39% 300.00 L.F.WINDOW ELEV. = 104.9024" @ 1.50% 300.00 L.F. 96.8097.30 104.3899.5093.25 97.4496.8097.3497.8836" @ 0.50% 107.87 L.F.36" @ 0.50% 88.00 L.F. EX. GROUND PROP. GRADE 7.582.20 90 100 110 120 130 90 100 110 120 130 STATION EX GROUND INVERT CUT HW32 RIM=103.3486 RIM=103.7887 012 PRECAST 36" CONCRETEHALF-HEIGHT HEADWALLSTA. 0+00.00PROPOSED CATCH BASINW/ 3'x1' WINDOW, ALL SIDESSTA. 1+07.87PROPOSED CATCH BASINW/ 3'x1' WINDOW, ALL SIDESSTA. 1+95.87WINDOW ELEV. = 102.28WINDOW ELEV. = 101.84STORM SEWER PROFILES 255 CG-159SEE DRAWING CG-158MATCH LINE JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:23 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-201-204.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING GRADING & DRAINAGE PLAN - DETAILSCG-201 257 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:33 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-201-204.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING N.T.S. STRUCTURE 1 DETAIL SEWER PIPE (25 LF) 12" DIAMETER PVC STORM ANTI SEEP COLLAR HALF HEIGHT HEADWALL 4'x4' CATCH BASIN 12" STM. TO HW9 CLAY TRENCH DAM INV.=95.60INV.=98.70 SOLID SCREW CAP RIM=101.50 BASIN = 94.10 BOTTOM OFINV.=95.60 INV.=98.70 8" ORIFICE NORMAL POOL = 98.70 N.T.S. LEVEL SPREADER CONCRETE WALL DETAIL REINFORCING STEEL (TYP) STEEL (TYP) REINFORCING 2'9"2'-9"6" 1'AS SPECIFIED 24" MAX. SPACED EQUALLY 12" MAX.SPACEDEQUALLYMAINTAIN 3" CLEAR BETWEEN OUTSIDE OF STRUCTURE AND REINFORCING STEEL.2. REINFORCING STEEL SHALL BE #5 BAR.1. NOTES: N.T.S. LEVEL SPREADER DETAIL 2'2'2'0.5'6" NO. 57 STONE GREATER THAN NO. 120 SIEVE SIZE AASHTO M288-06 CLASS 2, AOS NO NONWOVEN GEOTEXTILE FABRIC, GREATER THAN NO. 120 SIEVE SIZE AASHTO M288-06 CLASS 2, AOS NO NONWOVEN GEOTEXTILE FABRIC, GREATER THAN NO. 120 SIEVE SIZE AASHTO M288-06 CLASS 2, AOS NO NONWOVEN GEOTEXTILE FABRIC, 6" NO. 57 STONE (WHERE SPECIFIED) VEGETATED FILTER STRIP (WHERE SPECIFIED) 4" UNDERDRAIN 1.33'1.33'0.33'3' CONCRETE WALL SWALE N.T.S. STRUCTURE 1 LEVEL SPREADER AND FILTER STRIP (A) FILTER STRIP NO. 57 STONE SWALE 4" UNDERDRAIN TOP OF WALL = 98.36 CONCRETE WALL TOP OF WALL = 98.86 CONCRETE WALL 6" STEP IN WALL30'6'1'3'30' FLOW GRADING & DRAINAGE PLAN - DETAILSCG-202 258 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:33 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-201-204.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING N.T.S. STRUCTURE 8 DETAIL 36" STM. TO STRUCTURE 7 CLAY TRENCH DAM INV.=113.95 RIM=119.33 ELEV.=115.50 24"W X 6"H WINDOW ELEV.=117.70 36"W X 15.6"H WINDOW N.T.S. STRUCTURE 10 DETAIL SEWER PIPE (35 LF) 12" DIAMETER PVC STORM ANTI SEEP COLLAR HALF HEIGHT HEADWALL 4'x4' CATCH BASIN 24" STM. TO STRUCTURE 9 CLAY TRENCH DAM INV.=111.50INV.=113.15 SOLID SCREW CAP RIM=120.50 BASIN = 109.50 BOTTOM OFINV.=111.50 INV.=115.50 5" ORIFICE ELEV.=118.00 36"W X 18"H WINDOW NORMAL POOL = 115.50 NORMAL POOL = 115.50 N.T.S. STRUCTURE 10 LEVEL SPREADER AND FILTER STRIP (C) FILTER STRIP NO. 57 STONE SWALE 4" UNDERDRAIN TOP OF WALL = 114.34 CONCRETE WALL10'6'1'3'30' FLOW30'6'1'3'30' FILTER STRIP NO. 57 STONE SWALE 4" UNDERDRAIN TOP OF WALL = 115.00 CONCRETE WALL 12" OUTLET PIPE N.T.S. STRUCTURE 8 LEVEL SPREADER AND FILTER STRIP (B) FLOW GRADING & DRAINAGE PLAN - DETAILSCG-203 259 JACKSONVILLE, FLORIDA DESIGN & CONSTRUCTION ENGINEERING DEPARTMENT CSX TRANSPORTATION, INC. Evans, Mechwart, Hambleton & Tilton, Inc. Engineers • Surveyors • Planners • Scientists 5500 New Albany Road, Columbus, OH 43054 emht.com Phone: 614.775.4500 Toll Free: 888.775.3648 with the CSX Transportation. provided for in agreements used for any purpose not fidential; and shall not be and shall be held con- of the CSX Transportation shall remain the property mation furnished herewith ifications, and/or infor- all plans, drawings, spec- Information confidential DESIGNED BY APPROVED BY DRAWN BY CHECKED BY DATE SUB BY APPDATEREVDESCRIPTION DRAWING NO. REVISION SHEET NO. SCALE CONTRACT NO.PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENTAS SHOWN - - - - JANUARY 18, 2019 60% DRAWINGS VAL. SEC.- 78302/27/20197:43:34 PMJ:\20180935\Dgn\04Sheets\05-Grading and Drainage\CG-201-204.dgnNOT FOR CONSTRUCTION DRAFT CONFIDENTIAL CAROLINA CONNECTOR INTERMODAL RAIL TERMINAL ROCKY MOUNT, NORTH CAROLINA OF IF THIS DRAWING IS LESS THAN 22" X 34" IT IS A REDUCED SIZE DRAWING N.T.S. STRUCTURE 90 DETAIL INV.=97.02 4" ORIFICE NORMAL POOL = 97.02 SEWER PIPE (110 LF) 8" DIAMETER PVC STORM ANTI SEEP COLLAR HALF HEIGHT HEADWALL 4'x4' CATCH BASIN 12" STM. TO HW33 CLAY TRENCH DAM INV.=93.90INV.=97.02 SOLID SCREW CAP RIM=102.31 BASIN = 88.90 BOTTOM OFINV.=93.90 ELEV.=99.40 36"W X 18"H WINDOW NORMAL POOL = 97.02 N.T.S. STRUCTURE 89 DETAIL 24" STM. TO STRUCTURE 88 CLAY TRENCH DAM INV.=95.18 RIM=102.31 N.T.S. STRUCTURE 90 LEVEL SPREADER (D) FLOW TOP OF WALL = 96.23 CONCRETE WALL SWALE 4" UNDERDRAIN 6'1'3'10'N.T.S. HW34 LEVEL SPREADER (E) FLOW TOP OF WALL = 97.00 CONCRETE WALL SWALE 6'1'3'10'GRADING & DRAINAGE PLAN - DETAILSCG-204 260 + + + + + + + + + + + + + + + + + + + + + 115A VAL 6060+13 + + 113 EMT1 5954+92EMT1 6008+14114 STA. 6060+44.83 (MAI NLI NE 1)STA. 6060+41.97 (MAI NLI NE 2)STA. 6008+14.00 (MAINLINE 1)STA. 6008+14.00 (MAINLINE 2)STA. 5954+91.56 (MAINLINE 1)STA. 5954+91.56 (MAINLINE 2)7'-0"x6'-10"RES TROOMDRIV ERS7'-0"x7'-0"VESTIBULE DRI VERS12'-0"x16'-0"OFFICE12'-0"x16'-0"OFFICE12'-0"x16'-0"OFFICE 25'-0"x16'-0"CONF ERENCE ROOM 10'-0"x16'-0"ROOM STORAGE /FILE 24'-6"x16'-0"ROOM BREAK/TRAINING 16'-0"x16'-0"MECHANIC AL ROOM LOCKERS38 HALF -HEIGHT MEN'S RESTROOM LOCKERS26 HALF-HEIG HT WOMEN'S RES TROOM 8'-0"x6'-8"CLOSETJANITOR 8'-6"x7'-0"STORAGE23'-0"x18'-5"SERVER ROOM 26'-0"x18'-5"ROS ROO M14'-5"x11'-0"CLERK PLANNER/EXCE PTION STATIONS TO SERVER ROOMRACEWAYS IN FLOOR FROM ROS INSULATE THIS INTE RIOR WALL 22'-0"x50'-0"HOSTLER REPAIR 8'-0"x12'-0"MECHANICAL 10'-0"x12'-0" OFFICE 25'-0"x20'-0"CRANE PARTS 16'-0"x20'-0"PARTS 10'-0"x6'-0"TELECOMMUNICATIONS 10'-0"x11'-0"BREAKROOM RESTROOMWOMEN'S RESTROOMMEN'S INSULATE THIS INTERIOR WALL22'-0"x50'-0"HOSTLER/GRUNT REPAIR 70'-0"x24'-0"REPAIR BAY 10'-0"x12'-0"OFFICE 7'-0"x12'-0" TELECOM 9'-0"x12'-0"MECHANICALRESTROOMMEN'S RESTROOMWOMEN'S 25'-0"x12'-0"PARTS 70'-0"x24'-0"FUTURE REPAIR BAY SPANDRE L GLASS SPAND REL GLASS SPANDREL GLA SS12'Wx14'H OVERHEAD DOOR 12'Wx14'H OVERHEAD DOOR 12'Wx14'H OVERHEAD DOOR 12'Wx14'H OVERHEAD DOOR 8'Wx10'H OVERHEAD DOOR 10'Wx12'H OVERHEAD DOOR 14'Wx16'H OVERHEAD DOOR14'Wx16'H OVERHEAD DOOR8'Wx10'H OVERHEAD DOOR5'-1"x7'-0"ROOMTECHNOLOGYMONITORMONITOR6'-0" PICTURE WINDOW WITH AWNINGCOMPRESSOR PAD WITH AWNINGCOMPRESSOR PAD JACKSONVILLE, FLORIDADESIGN & CONSTRUCTIONENGINEERING DEPARTMENT CSX TRANSPORTATION, INC.Evans, Mechwart, Hambleton & Tilton, Inc.Engineers • Surveyors • Planners • Scientists5500 New Albany Road, Columbus, OH 43054emht.comPhone: 614.775.4500Toll Free: 888.775.3648100 105 95 95 10 0 100 1 0 5 1 0 5 110115115 110105100 115120120 1251 2 5 130130130125125125 120 125 12 0 1251251 2 0 120 120 125 12 0 125 125 12 5 1 2 5 12 5 12 5 13 0 130 130130 13 0 130 125 12 5 125 125125 1251251201 2 5 1 2 0120125 1 20 115 1 2 0 1201 25 1 2 5125125120125125 120120120 115 115115110 110110105105 100 100 100105 100 95 95 95 9 0 9 0 90 90 100 100 1 0 0 105 105 110 115 120125115 110 110 10 5 90 90 90 95100 1051101009 5 105115 115 100 100 90 90 95130130 130 130 130125 125 120 120 125 115 120 105100 10 0 105 1 0 5 10 5 100 95 100 10095 105 105 110 110 110 115 105 100 115 8 5 95 95 90 100 100 105110 115 95 1151 0 0 1 0 5 110105 90 9590 110 115 115 120 125 UNDETAINED 101 UNDETAINED 101 DETAINED SUBAREA 101 DETAINED SUBAREA 102 POND 2DETAINED SUBAREA 102 POND 3 UNDETAINED 102 UNDETAINED 102UNDETAINED 103UNDETAINED 103 UNDETAINED 103 DETAINED SUBAREA 103 DETAINED SUBAREA 104 UNDETAINED 104 UNDETAINED 104 POND 1FOREBAY 1 FOREBAY 2 FOREBAY 3 FOREBAY 4FOREBAY 5 FOREBAY 6 FOREBAY 8 POND 2 POND 3 POND 3 POND 4 POND 5 FOREBAY 7 UNDETAINED 101 PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT11/18/201810:31:05 PMJ:\20180935\Dgn\04Sheets\Exhibits\Stormwater\CS-001.dgnTransportation.with the CSX in agreementsprovided for any purpose not shall not be used for con-fidential; and and shall be held Transportationof the CSX remain the property here with shall information furnished specifications, and/or all plans, drawings, confidentialInformation DESIGNED BYAPPROVED BYDRAWN BYCHECKED BYDATESUBBYAPPDATEREVDESCRIPTIONDRAWING NO. REVISIONSHEET NO. SCALECONTRACT NO.1" = 100'----EXHIBITVAL. SEC.CD-001-0NOT FOR CONSTRUCTIONDRAFT CONFIDENTIAL1 OF 10 100'200'100' GRAPHIC SCALE: 1" = 100'CAROLINA CONNECTORINTERMODAL RAIL TERMINALSITE PLANROCKY MOUNT, NORTH CAROLINANOVEMBER 16, 2018IF THIS DRAWING IS LESS THAN 22" X 162" IT IS A REDUCED SIZE DRAWING + + + + + + + + + + + + + + + + + + + + + 115A VAL 6060+13 + + 113 EMT1 5954+92EMT1 6008+14114 STA. 6060+44.83 (MAI NLI NE 1)STA. 6060+41.97 (MAI NLI NE 2)STA. 6008+14.00 (MAINLINE 1)STA. 6008+14.00 (MAINLINE 2)STA. 5954+91.56 (MAINLINE 1)STA. 5954+91.56 (MAINLINE 2)7'-0"x6'-10"RES TROOMDRIV ERS7'-0"x7'-0"VESTIBULE DRI VERS12'-0"x16'-0"OFFICE12'-0"x16'-0"OFFICE12'-0"x16'-0"OFFICE 25'-0"x16'-0"CONF ERENCE ROOM 10'-0"x16'-0"ROOM STORAGE /FILE 24'-6"x16'-0"ROOM BREAK/TRAINING 16'-0"x16'-0"MECHANIC AL ROOM LOCKERS38 HALF -HEIGHT MEN'S RESTROOM LOCKERS26 HALF-HEIG HT WOMEN'S RES TROOM 8'-0"x6'-8"CLOSETJANITOR 8'-6"x7'-0"STORAGE23'-0"x18'-5"SERVER ROOM 26'-0"x18'-5"ROS ROO M14'-5"x11'-0"CLERK PLANNER/EXCE PTION STATIONS TO SERVER ROOMRACEWAYS IN FLOOR FROM ROS INSULATE THIS INTE RIOR WALL 22'-0"x50'-0"HOSTLER REPAIR 8'-0"x12'-0"MECHANICAL 10'-0"x12'-0" OFFICE 25'-0"x20'-0"CRANE PARTS 16'-0"x20'-0"PARTS 10'-0"x6'-0"TELECOMMUNICATIONS 10'-0"x11'-0"BREAKROOM RESTROOMWOMEN'S RESTROOMMEN'S INSULATE THIS INTERIOR WALL22'-0"x50'-0"HOSTLER/GRUNT REPAIR 70'-0"x24'-0"REPAIR BAY 10'-0"x12'-0"OFFICE 7'-0"x12'-0" TELECOM 9'-0"x12'-0"MECHANICALRESTROOMMEN'S RESTROOMWOMEN'S 25'-0"x12'-0"PARTS 70'-0"x24'-0"FUTURE REPAIR BAY SPANDRE L GLASS SPAND REL GLASS SPANDREL GLA SS12'Wx14'H OVERHEAD DOOR 12'Wx14'H OVERHEAD DOOR 12'Wx14'H OVERHEAD DOOR 12'Wx14'H OVERHEAD DOOR 8'Wx10'H OVERHEAD DOOR 10'Wx12'H OVERHEAD DOOR 14'Wx16'H OVERHEAD DOOR14'Wx16'H OVERHEAD DOOR8'Wx10'H OVERHEAD DOOR5'-1"x7'-0"ROOMTECHNOLOGYMONITORMONITOR6'-0" PICTURE WINDOW WITH AWNINGCOMPRESSOR PAD WITH AWNINGCOMPRESSOR PAD JACKSONVILLE, FLORIDADESIGN & CONSTRUCTIONENGINEERING DEPARTMENT CSX TRANSPORTATION, INC.Evans, Mechwart, Hambleton & Tilton, Inc.Engineers • Surveyors • Planners • Scientists5500 New Albany Road, Columbus, OH 43054emht.comPhone: 614.775.4500Toll Free: 888.775.3648100 105 95 95 10 0 100 1 0 5 1 0 5 110115115 110105100 115120120 1251 2 5 130130130125125125 120 125 12 0 1251251 2 0 120 120 125 12 0 125 125 12 5 1 2 5 12 5 12 5 13 0 130 130130 13 0 130 125 12 5 125 125125 1251251201 2 5 1 2 0120125 1 20 115 1 2 0 1201 25 1 2 5125125120125125 120120120 115 115115110 110110105105 100 100 100105 100 95 95 95 9 0 9 0 90 90 100 100 1 0 0 105 105 110 115 120125115 110 110 10 5 90 90 90 95100 1051101009 5 105115 115 100 100 90 90 95130130 130 130 130125 125 120 120 125 115 120 105100 10 0 105 1 0 5 10 5 100 95 100 10095 105 105 110 110 110 115 105 100 115 8 5 95 95 90 100 100 105110 115 95 1151 0 0 1 0 5 110105 90 9590 110 115 115 120 125 UNDETAINED 101 UNDETAINED 101 DETAINED SUBAREA 101 DETAINED SUBAREA 102 POND 2DETAINED SUBAREA 102 POND 3 UNDETAINED 102 UNDETAINED 102UNDETAINED 103UNDETAINED 103 UNDETAINED 103 DETAINED SUBAREA 103 DETAINED SUBAREA 104 UNDETAINED 104 UNDETAINED 104 POND 1FOREBAY 1 FOREBAY 2 FOREBAY 3 FOREBAY 4FOREBAY 5 FOREBAY 6 FOREBAY 8 POND 2 POND 3 POND 3 POND 4 POND 5 FOREBAY 7 UNDETAINED 101 PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT11/18/201810:31:05 PMJ:\20180935\Dgn\04Sheets\Exhibits\Stormwater\CS-001.dgnTransportation.with the CSX in agreementsprovided for any purpose not shall not be used for con-fidential; and and shall be held Transportationof the CSX remain the property here with shall information furnished specifications, and/or all plans, drawings, confidentialInformation DESIGNED BYAPPROVED BYDRAWN BYCHECKED BYDATESUBBYAPPDATEREVDESCRIPTIONDRAWING NO. REVISIONSHEET NO. SCALECONTRACT NO.1" = 100'----EXHIBITVAL. SEC.CD-001-0NOT FOR CONSTRUCTIONDRAFT CONFIDENTIAL1 OF 10 100'200'100' GRAPHIC SCALE: 1" = 100'CAROLINA CONNECTORINTERMODAL RAIL TERMINALSITE PLANROCKY MOUNT, NORTH CAROLINANOVEMBER 16, 2018IF THIS DRAWING IS LESS THAN 22" X 162" IT IS A REDUCED SIZE DRAWING 0 100'200'100' GRAPHIC SCALE: 1" = 100' + + + + + + + + + + + + + + + + + + + + + 115A VAL 6060+13 + + 113 EMT1 5954+92EMT1 6008+14114 STA. 6060+44.83 (MAI NLI NE 1)STA. 6060+41.97 (MAI NLI NE 2)STA. 6008+14.00 (MAINLINE 1)STA. 6008+14.00 (MAINLINE 2)STA. 5954+91.56 (MAINLINE 1)STA. 5954+91.56 (MAINLINE 2)7'-0"x6'-10"RES TROOMDRIV ERS7'-0"x7'-0"VESTIBULE DRI VERS12'-0"x16'-0"OFFICE12'-0"x16'-0"OFFICE12'-0"x16'-0"OFFICE 25'-0"x16'-0"CONF ERENCE ROOM 10'-0"x16'-0"ROOM STORAGE /FILE 24'-6"x16'-0"ROOM BREAK/TRAINING 16'-0"x16'-0"MECHANIC AL ROOM LOCKERS38 HALF -HEIGHT MEN'S RESTROOM LOCKERS26 HALF-HEIG HT WOMEN'S RES TROOM 8'-0"x6'-8"CLOSETJANITOR 8'-6"x7'-0"STORAGE23'-0"x18'-5"SERVER ROOM 26'-0"x18'-5"ROS ROO M14'-5"x11'-0"CLERK PLANNER/EXCE PTION STATIONS TO SERVER ROOMRACEWAYS IN FLOOR FROM ROS INSULATE THIS INTE RIOR WALL 22'-0"x50'-0"HOSTLER REPAIR 8'-0"x12'-0"MECHANICAL 10'-0"x12'-0" OFFICE 25'-0"x20'-0"CRANE PARTS 16'-0"x20'-0"PARTS 10'-0"x6'-0"TELECOMMUNICATIONS 10'-0"x11'-0"BREAKROOM RESTROOMWOMEN'S RESTROOMMEN'S INSULATE THIS INTERIOR WALL22'-0"x50'-0"HOSTLER/GRUNT REPAIR 70'-0"x24'-0"REPAIR BAY 10'-0"x12'-0"OFFICE 7'-0"x12'-0" TELECOM 9'-0"x12'-0"MECHANICALRESTROOMMEN'S RESTROOMWOMEN'S 25'-0"x12'-0"PARTS 70'-0"x24'-0"FUTURE REPAIR BAY SPANDRE L GLASS SPAND REL GLASS SPANDREL GLA SS12'Wx14'H OVERHEAD DOOR 12'Wx14'H OVERHEAD DOOR 12'Wx14'H OVERHEAD DOOR 12'Wx14'H OVERHEAD DOOR 8'Wx10'H OVERHEAD DOOR 10'Wx12'H OVERHEAD DOOR 14'Wx16'H OVERHEAD DOOR14'Wx16'H OVERHEAD DOOR8'Wx10'H OVERHEAD DOOR5'-1"x7'-0"ROOMTECHNOLOGYMONITORMONITOR6'-0" PICTURE WINDOW WITH AWNINGCOMPRESSOR PAD WITH AWNINGCOMPRESSOR PAD JACKSONVILLE, FLORIDADESIGN & CONSTRUCTIONENGINEERING DEPARTMENT CSX TRANSPORTATION, INC.Evans, Mechwart, Hambleton & Tilton, Inc.Engineers • Surveyors • Planners • Scientists5500 New Albany Road, Columbus, OH 43054emht.comPhone: 614.775.4500Toll Free: 888.775.3648100 105 95 95 10 0 100 1 0 5 1 0 5 110115115 110105100 115120120 1251 2 5 130130130125125125 120 125 12 0 1251251 2 0 120 120 125 12 0 125 125 12 5 1 2 5 12 5 12 5 13 0 130 130130 13 0 130 125 12 5 125 125125 1251251201 2 5 1 2 0120125 1 20 115 1 2 0 1201 25 1 2 5125125120125125 120120120 115 115115110 110110105105 100 100 100105 100 95 95 95 9 0 9 0 90 90 100 100 1 0 0 105 105 110 115 120125115 110 110 10 5 90 90 90 95100 1051101009 5 105115 115 100 100 90 90 95130130 130 130 130125 125 120 120 125 115 120 105100 10 0 105 1 0 5 10 5 100 95 100 10095 105 105 110 110 110 115 105 100 115 8 5 95 95 90 100 100 105110 115 95 1151 0 0 1 0 5 110105 90 9590 110 115 115 120 125 UNDETAINED 101 UNDETAINED 101 DETAINED SUBAREA 101 DETAINED SUBAREA 102 POND 2DETAINED SUBAREA 102 POND 3 UNDETAINED 102 UNDETAINED 102UNDETAINED 103UNDETAINED 103 UNDETAINED 103 DETAINED SUBAREA 103 DETAINED SUBAREA 104 UNDETAINED 104 UNDETAINED 104 POND 1FOREBAY 1 FOREBAY 2 FOREBAY 3 FOREBAY 4FOREBAY 5 FOREBAY 6 FOREBAY 8 POND 2 POND 3 POND 3 POND 4 POND 5 FOREBAY 7 UNDETAINED 101 PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT11/18/201810:31:05 PMJ:\20180935\Dgn\04Sheets\Exhibits\Stormwater\CS-001.dgnTransportation.with the CSX in agreementsprovided for any purpose not shall not be used for con-fidential; and and shall be held Transportationof the CSX remain the property here with shall information furnished specifications, and/or all plans, drawings, confidentialInformation DESIGNED BYAPPROVED BYDRAWN BYCHECKED BYDATESUBBYAPPDATEREVDESCRIPTIONDRAWING NO. REVISIONSHEET NO. SCALECONTRACT NO.1" = 100'----EXHIBITVAL. SEC.CD-001-0NOT FOR CONSTRUCTIONDRAFT CONFIDENTIAL1 OF 10 100'200'100' GRAPHIC SCALE: 1" = 100'CAROLINA CONNECTORINTERMODAL RAIL TERMINALSITE PLANROCKY MOUNT, NORTH CAROLINANOVEMBER 16, 2018IF THIS DRAWING IS LESS THAN 22" X 162" IT IS A REDUCED SIZE DRAWING 0 100'200'100' GRAPHIC SCALE: 1" = 100' + + + + + + + + + + + + + + + + + + + + + 115A VAL 6060+13 + + 113 EMT1 5954+92EMT1 6008+14114 STA. 6060+44.83 (MAI NLI NE 1)STA. 6060+41.97 (MAI NLI NE 2)STA. 6008+14.00 (MAINLINE 1)STA. 6008+14.00 (MAINLINE 2)STA. 5954+91.56 (MAINLINE 1)STA. 5954+91.56 (MAINLINE 2)7'-0"x6'-10"RES TROOMDRIV ERS7'-0"x7'-0"VESTIBULE DRI VERS12'-0"x16'-0"OFFICE12'-0"x16'-0"OFFICE12'-0"x16'-0"OFFICE 25'-0"x16'-0"CONF ERENCE ROOM 10'-0"x16'-0"ROOM STORAGE /FILE 24'-6"x16'-0"ROOM BREAK/TRAINING 16'-0"x16'-0"MECHANIC AL ROOM LOCKERS38 HALF -HEIGHT MEN'S RESTROOM LOCKERS26 HALF-HEIG HT WOMEN'S RES TROOM 8'-0"x6'-8"CLOSETJANITOR 8'-6"x7'-0"STORAGE23'-0"x18'-5"SERVER ROOM 26'-0"x18'-5"ROS ROO M14'-5"x11'-0"CLERK PLANNER/EXCE PTION STATIONS TO SERVER ROOMRACEWAYS IN FLOOR FROM ROS INSULATE THIS INTE RIOR WALL 22'-0"x50'-0"HOSTLER REPAIR 8'-0"x12'-0"MECHANICAL 10'-0"x12'-0" OFFICE 25'-0"x20'-0"CRANE PARTS 16'-0"x20'-0"PARTS 10'-0"x6'-0"TELECOMMUNICATIONS 10'-0"x11'-0"BREAKROOM RESTROOMWOMEN'S RESTROOMMEN'S INSULATE THIS INTERIOR WALL22'-0"x50'-0"HOSTLER/GRUNT REPAIR 70'-0"x24'-0"REPAIR BAY 10'-0"x12'-0"OFFICE 7'-0"x12'-0" TELECOM 9'-0"x12'-0"MECHANICALRESTROOMMEN'S RESTROOMWOMEN'S 25'-0"x12'-0"PARTS 70'-0"x24'-0"FUTURE REPAIR BAY SPANDRE L GLASS SPAND REL GLASS SPANDREL GLA SS12'Wx14'H OVERHEAD DOOR 12'Wx14'H OVERHEAD DOOR 12'Wx14'H OVERHEAD DOOR 12'Wx14'H OVERHEAD DOOR 8'Wx10'H OVERHEAD DOOR 10'Wx12'H OVERHEAD DOOR 14'Wx16'H OVERHEAD DOOR14'Wx16'H OVERHEAD DOOR8'Wx10'H OVERHEAD DOOR5'-1"x7'-0"ROOMTECHNOLOGYMONITORMONITOR6'-0" PICTURE WINDOW WITH AWNINGCOMPRESSOR PAD WITH AWNINGCOMPRESSOR PAD JACKSONVILLE, FLORIDADESIGN & CONSTRUCTIONENGINEERING DEPARTMENT CSX TRANSPORTATION, INC.Evans, Mechwart, Hambleton & Tilton, Inc.Engineers • Surveyors • Planners • Scientists5500 New Albany Road, Columbus, OH 43054emht.comPhone: 614.775.4500Toll Free: 888.775.3648100 105 95 95 10 0 100 1 0 5 1 0 5 110115115 110105100 115120120 1251 2 5 130130130125125125 120 125 12 0 1251251 2 0 120 120 125 12 0 125 125 12 5 1 2 5 12 5 12 5 13 0 130 130130 13 0 130 125 12 5 125 125125 1251251201 2 5 1 2 0120125 1 20 115 1 2 0 1201 25 1 2 5125125120125125 120120120 115 115115110 110110105105 100 100 100105 100 95 95 95 9 0 9 0 90 90 100 100 1 0 0 105 105 110 115 120125115 110 110 10 5 90 90 90 95100 1051101009 5 105115 115 100 100 90 90 95130130 130 130 130125 125 120 120 125 115 120 105100 10 0 105 1 0 5 10 5 100 95 100 10095 105 105 110 110 110 115 105 100 115 8 5 95 95 90 100 100 105110 115 95 1151 0 0 1 0 5 110105 90 9590 110 115 115 120 125 UNDETAINED 101 UNDETAINED 101 DETAINED SUBAREA 101 DETAINED SUBAREA 102 POND 2DETAINED SUBAREA 102 POND 3 UNDETAINED 102 UNDETAINED 102UNDETAINED 103UNDETAINED 103 UNDETAINED 103 DETAINED SUBAREA 103 DETAINED SUBAREA 104 UNDETAINED 104 UNDETAINED 104 POND 1FOREBAY 1 FOREBAY 2 FOREBAY 3 FOREBAY 4FOREBAY 5 FOREBAY 6 FOREBAY 8 POND 2 POND 3 POND 3 POND 4 POND 5 FOREBAY 7 UNDETAINED 101 PHYSICALENTITYCONTRACTDESIGNATORITEMLINECOSTELEMENTNUMBERPROJECTWORK ELEMENT11/18/201810:31:05 PMJ:\20180935\Dgn\04Sheets\Exhibits\Stormwater\CS-001.dgnTransportation.with the CSX in agreementsprovided for any purpose not shall not be used for con-fidential; and and shall be held Transportationof the CSX remain the property here with shall information furnished specifications, and/or all plans, drawings, confidentialInformation DESIGNED BYAPPROVED BYDRAWN BYCHECKED BYDATESUBBYAPPDATEREVDESCRIPTIONDRAWING NO. REVISIONSHEET NO. SCALECONTRACT NO.1" = 100'----EXHIBITVAL. SEC.CD-001-0NOT FOR CONSTRUCTIONDRAFT CONFIDENTIAL1 OF 10 100'200'100' GRAPHIC SCALE: 1" = 100'CAROLINA CONNECTORINTERMODAL RAIL TERMINALSITE PLANROCKY MOUNT, NORTH CAROLINANOVEMBER 16, 2018IF THIS DRAWING IS LESS THAN 22" X 162" IT IS A REDUCED SIZE DRAWING 0 100'200'100' GRAPHIC SCALE: 1" = 100' Tributary A-1 Wetland 10 Tributary I-2 TributaryB-1 Tributary K TributaryI-1 Tributary A-1 TributaryB-2 Tributary A-1 Wetland 4 Wetland 12 Wetland 11 Wetland 7 Wetland 6 Wetland 13 Wetland 10 I 0 0.50.25 Miles Legend Swi ft C ree k P rop ert y(~593 Ac res ) Swi ft C ree k M itig ati on Site(~196.5 Acr es) Pro po sed St rea m M itig at io n Headwater S tre am R es tor ati on(~1,589 L F) Pri ori ty 1 S tr ea m R e sto ra tio n(~6,604 L F) Str eam Pre se rv ati on(~383 LF ) Ephemeral D itc h(~749) Pro po sed We tla nd M itig at io n Wet land En ha nc em en t(~17.0 Ac re s) Wet land Pr ese rv ati on(~34.9 Ac re s) Wetl and Pr ese rva tio n C onv ert ed toRiparian B uffe r P res erv atio n(~11.0 Ac res ) Image ry So urc e: NC OneMap \\CBA-FS1\projects\Environmental\2012 + Projects\0180 - Palustrine - REV. Swift Creek\GIS\Report Figures\Figure 14a. Mitigation Work Plan.mxdFigure 14a. Mitigation WorkPlan Map Swift Creek - PermitteeResponsible Mitigation Plan Edgec om be Cou nty, No rth Ca roli na FEATURE NAME PROPOSED LENGTH (LF)PROPOSED SINUOSITY MITIGATION CREDIT GENERATION RATIO PROPOSED MITIGATION CREDIT GENERATIONTRIBUTARY A-1 (Headwater)533 1.00 1:1 533.0TRIBUTARY A-1 5,925 1.20 1:1 5,925.0TRIBUTARY B-2 (Headwater)1,056 1.00 1:1 1,056.0TRIBUTARY K 679 1.20 1:1 679.07,514.0 FEATURE NAME PROPOSED LENGTH (LF)MITIGATION CREDIT GENERATION RATIOTRIBUTARY B-1 383 5:1 FEATURE NAME ACREAGE (Acres)MITIGATION CREDIT GENERATION RATIOWETLAND NO. 7 0.3 2.5:1WETLAND NO. 11 5.6 2.5:1WETLAND NO. 12 11.1 2.5:1 FEATURE NAME ACREAGE (Acres)MITIGATION CREDIT GENERATION RATIOWETLAND NO. 4 2.1 5:1WETLAND NO. 5 0.01 5:1WETLAND NO. 6 0.06 5:1WETLAND NO. 10 29.5 5:1WETLAND NO. 13 3.2 5:1 TOTAL WETLAND MITIGATION CREDIT GENERATION 13.78 0.000.015.910.63WETLAND PRESERVATION CREDIT SUBTOTAL 6.98 0.42 ENHANCEMENT PROPOSED MITIGATION CREDIT GENERATION 0.142.224.44WETLAND ENHANCEMENT CREDIT SUBTOTAL 6.80PRESERVATION PROPOSED MITIGATION CREDIT GENERATION PROPOSED MITIGATION CREDIT GENERATION 76.6 SWIFT CREEK - PERMITTEE RESPONSIBLE MITIGATION WORK PLANSTREAM MITIGATIONRESTORATION STREAM RESTORATION CREDIT SUBTOTALPRESERVATION WETLAND MITIGATION STREAM PRESERVATION CREDIT SUBTOTAL 76.6TOTAL STREAM MITIGATION CREDIT GENERATION 7,590.6 Date: 4/12/2019 Job No. 6250-18-0180 Drawn By: B WS Rev iewed By: WA R The map shown here has beencreated with all due andreasonable care and is strictly foruse with Wood, project number6250180180, and PalustrineGroup. Wood assumes noliability, direct or indirect,whatsoever for any such thirdparty or unintended use. !(!( !( !( !( !(!( !( !( ") ") ")") ") ")")") ")")")!(")") !( !( NC 33 NWWHITE OAK SWAMPUV1207£¤64 £¤258 £¤258 UV44 UV33 UV122 UV111UV1124UV44 UV44 UV33 I Image ry So urc e: USGS Earth Explorer I 0 73.5 Miles \\CBA-FS1\projects\Environmental\2012 + Projects\0180 - Palustrine - REV. Swift Creek\GIS\Report Figures\Figure 17. Proposed Monitoring Plan Map.mxd0 0.50.25 Miles Figure 17. ProposedMonitoring Plan Map Legend Swift C reek Property(~593 Acres) Swift C reek Mitigation Site(~196.5 Acres) ") Propos ed Perm anentVegetation Monitoring P lots(13 P lots ) !( Propos ed ShallowGroundwater Monitoring W el ls(7 W ells) !(Propos ed Stream Gauge(5 Gauges) Swift Creek - PermitteeResponsible Mitigation PlanEdgecombe Cou nty, No rth Ca roli na Date: 4/12/2019 Job No. 6250-18-0180 Drawn By: B WS Rev iewed By: WA R The map shown here has beencreated with all due andreasonable care and is strictly foruse with Wood, project number6250180180, and PalustrineGroup. Wood assumes noliability, direct or indirect,whatsoever for any such thirdparty or unintended use. Mitigation Work Plan Riparian Buffer Restoration(TOB-100')(~13.95 Acres) Riparian Buffer Restoration(100' - 200')(~11.69 Acres ) Riparian Buffer Preservation(TOB-100')(~15.2 Ac res / 8.70 Acres is 25%CAP) Wetland Enhanc ement(~17.0 Ac res ) Wetland Pres erv ation(~34.9 Ac res ) Headwater Stream Res toration(~1,589 LF) Priority 1 Stream Restoration(~6,604 LF) Stream Preserv ation(~383 LF) Tributary A-1 Wetland 10 Tributary I-2 TributaryB-1 Tributary K TributaryI-1 Tributary A-1 TributaryB-2 Tributary A-1 Wetland 4 Wetland 12 Wetland 11 Wetland 7 Wetland 6 Wetland 13 Wetland 10 I0 1,400700Feet Legend PlantiingPlanZone3 PlantingPlanZone2 PlantingPlanZone1 Swift C reek P roperty(~593 Acres) Swift C reek Mitigation Site(~196.5 Acres) Mitigation Workplan Proposed S tream Mitigation Headwater Stream R estoration(~1,589 LF) Priority 1 Stream R estoration(~6,604 LF) Stream Preser vation(~383 LF) Ephemer al Ditch(~749 LF) Tar-Pamilico Riparian Buffer Mitigation Riparian B uffer R estoration(TOB -100')(~13.95 Acres) Riparian B uffer R estoration(100' - 200')(~11.69 A cres) Riparian B uffer P reservation(TOB -100')(~15.2 Acres / 8.70 A cr es is 25% CA P) Wetland Enhancement(~17.0 Acres) Wetland Pr eservation(~34.9 Acres) Wetland Preservation Converted toRiparian Buffer Pr eservation(~11.0 A cr es) Image ry So urc e: NC OneMap \\CBA-FS1\projects\Environmental\2012 + Projects\0180 - Palustrine - REV. Swift Creek\GIS\Report Figures\Figure 18. Proposed Planting Plan Map.mxdFigure 18. Proposed PlantingPlan Swift Creek - PermitteeResponsible Mitigation Plan Edgec om be Cou nty, No rth Ca roli na Date: 4/16/2019 Job No. 6250-18-0180 Drawn By : JK L Rev iewed By : BWS The map shown here has beencreated with all due andreasonable care and is strictly foruse with Wood, project number6250180180, and PalustrineGroup. Wood assumes noliability, direct or indirect,whatsoever for any such thirdparty or unintended use. LOCATION VEGETATION ACRES SQUARE FEET ZONE 1 MIXED HARDWOOD 35.5 1,548,531 ZONE 2 BOTTOMLA ND HARDWOOD 25.7 1,117,649 ZONE 3 CYPRESS / GUM SWAMP 16.6 721,401 77.8 2,815,663 SW IFT CREEK - PERMITEE RESOPONSIBLE MITIGATION PLANTING PLAN TOTAL PLANTING AREA Tributary A-1 Wetland 10 Tributary I-2 TributaryB-1 Tributary K TributaryI-1 Tributary A-1 TributaryB-2 Tributary A-1 Wetland 4 Wetland 12 Wetland 11 Wetland 7 Wetland 6 Wetland 13 Wetland 10 I0 1,400700Feet Legend Swift C reek P roperty(~593 Acres) Swift C reek Mitigation Site(~196.5 Acres) Mitigation Workplan Proposed S tream Mitigation Headwater Stream R estoration(~1,589 LF) Priority 1 Stream R estoration(~6,604 LF) Stream Preser vation(~383 LF) Ephemer al Ditch(~740 LF) Tar-Pamilico Riparian Buffer Mitigation Riparian B uffer R estoration(TOB -100')(~13.95 Acres) Riparian B uffer R estoration(100' - 200')(~11.69 A cres) Riparian B uffer P reservation(TOB -100')(~15.2 Acres / 8.70 A cr es is 25% CA P) Wetland Enhancement(~17.0 Acres) Wetland Pr eservation(~34.9 Acres) Wetland Preservation Converted toRiparian Buffer Pr eservation(~11.0 A cr es) Image ry So urc e: NC OneMap \\CBA-FS1\projects\Environmental\2012 + Projects\0180 - Palustrine - REV. Swift Creek\GIS\Report Figures\Figure 14b. Mitigation Work Plan.mxdFigure 14b. Tar-PamlicoRiparian Buffer Plan Swift Creek - PermitteeResponsible Mitigation Plan Edgec om be Cou nty, No rth Ca roli na Date: 4/12/2019 Job No. 6250-18-0180 Drawn By: B WS Rev iewed By: WA R The map shown here has beencreated with all due andreasonable care and is strictly foruse with Wood, project number6250180180, and PalustrineGroup. Wood assumes noliability, direct or indirect,whatsoever for any such thirdparty or unintended use. FEATURE NAME RIPARIAN WIDTH MITIGATION TYPE ACRES SQUARE FEET CREDIT RATIO % FULL CREDIT TRIBUTARY A-1 TOB - 100'RESTORATION 12.72 554,083 1:1 100%12.72 554,083TRIBUTARY K TOB - 100'RESTORATION 1.23 53,579 1:1 100%1.23 53,57913.95 607,662 13.95 607,662.00TRIBUTARY A-1 100'-200'RESTORATION 10.98 478,289 1:3 100%3.66 159,430TRIBUTARY K 100'-200'RESTORATION 0.71 30,928 1:3 100%0.24 10,30911.69 509,216 3.90 169,7398.55 372,293 TRIBUTARY A-1 TOB - 100'PRESERV ATION 8.12 353,707 1:10 100%0.81 35,371 TRIBUTARY B-1 TOB - 100'PRESERV ATION 1.09 47,480 1:10 53%0.06 2,516TRIBUTARY B-2 TOB - 100'PRESERV ATION 2.13 92,783 1:10 0%0.00 0TRIBUTARY K TOB - 100'PRESERV ATION 0.88 38,333 1:5 0%0.00 0 TRIBUTARY I-1 TOB - 100'PRESERV ATION 2.98 129,809 1:5 0%0.00 0 8.70 378,872 0.87 37,88718.72 815,288 SWIFT CREEK - PERMITTEE RESPONSIBLE MITIGATION WORK PLANTAR-PAMLI CO RIPARIAN BUFFER MITIGATION PROPOSED MITIGATION CREDIT GENERATION (Acres / Sq. Ft.) MAXIMUM ALLOWABLE PRESERVATION/EPHEMERAL CREDIT GEN ERATION (25% CAP) ACRES/SQ. FEET TOTAL BUFFER PRESERVATION (TOB - 100')TOTAL RIPARIAN BUFFER MITIGATION CREDIT GENERATION TOTAL BUFFER RESROATION (TOB - 100') TOTAL BUFFER RESROATION (100' - 200')