HomeMy WebLinkAboutNC0033111_Compliance Evaluation Inspection_20190214 • cYA� • . 7u yy 2 ROY COOPER 1"-' ,b, . j Governor "„'- . MICHAEL S.REGAIN ~ Secretary °°� '� LINDA CULPEPPER NORTH CAROLINA Director Environmental Quality February 14, 2019 Bryce Mendenhall Carolina Water Service Inc of North Carolina PO Box 240908 Charlotte, NC 28224-0908 SUBJECT: Compliance Inspection Report Fairfield Harbour S/D WWTP - NPDES WW Permit No. NC0033111 Craven County • Dear Mr. Mendenhall: The North Carolina Division of Water Resources conducted an inspection of the Fairfield Harbour S/D WWTP on 2/13/2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0033111. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Stewart White with the Water Quality Regional Operations Section in the Washington Regional Office at 252-946-6481 or via email at stewart.white@ncdenr.gov. Sincerely, Stewart White, Environmental Specialist I Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Washington Regional Office , NPDES Compliance/Enforcement Unit DE ' North ngelonma Depert Le t of Emv�iroismeMal Q wrr&ity I Dsi:si are of Water Resew ro s 4 Washi ton Regiortsl Offios 943 Washington 5t;u$re ht i Washington,North Carolina 27859 °yis"' m•o� /`� 252-845"6431 United States Environmental Protection Agency Form Approved EPA Washington,D.0 20460 OMB No 2040-0057 • Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding(r e,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 NI, I 2 EI 3 I NC0033111 I11 121 19/02/13 117 18[ j 19 I c l 201 21IIIIIIIIIIllI ! llllllllllllllllII � � _� IIIIl66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA - Reserved ` 67I I 701�LJ LJ 1 71 I 72 1 , 1 73I I 174 75IJ 1 1 1 1 1 1180 Section B.Facility Data l Name and Location of Facility Inspected(For Industnal Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09 15AM 19/02/13 18/07/01 Fairfield Harbour S/D WWTP 200 Broad Creek Rd Exit Time/Date Permit Expiration Date New Bern NC 28560 11 35AM 19/02/13 23/06/30 Name(s)of Onsite Representative(s)/Pitles(s)/Phone and Fax Number(s) Other Facility Data /// Matthew Golden/ORC/252-659-0517/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Martin Lashua,PO Box 240908 Charlotte NC 282240908004-319-0517/7045258174 No Section C Areas Evaluated During Inspection(Check only those areas evaluated) Permit II Flow Measurement 1. Operations&Maintenance 111 Records/Reports II Sludge Handling Disposal II Facility Site Review • Effluent/Receiving Waters II Laboratory Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Q Stewart White WARD WQ//252-948-3940/ — J , 41.311 i Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3(Rev 9-94)Previous editions are obsolete Page# 1 NPDES yr/mo/day Inspection Type (Cont) 1 31 NC0033111 111 121 19/02/13 117 18 Ls] Section D.Summary of Finding/Comments(Attach additional sheetsof narrative and checklists as necessary) Stewart White and Allen Clark met with Carolina Water Service supervisor Eddie Baldwin Back-up ORC and newly designated ORC Matthew Golden at the WWTP Mr.Baldwin and Mr Golden were very helpful during the inspection.They have done an outstanding job recovering from Hurricane Florence and on going repairs were being done. There was a lot of homes damaged and residents were still not back in their homes. Carolina Water Service have replaced and repaired pump stations. The WWTP effluent looks good The Total Nitrogen Annual Load Exceeded 11263#lbs/Year permit limit with 11415#Ibs/Year The facility is a member of the Neuse River Compliance Association. Page# 2 t Permit NC0033111 Owner-Facility: Fairfield Harbour S/D VVWTP Inspection Date: 02/13/2019 Inspection Type. Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less) Has the permittee submitted a new ❑ ❑ • ❑ application? Is the facility as described in the permit? • 0 ❑ ❑ #Are there any special conditions for the permit? • ❑ ❑ ❑ Is access to the plant site restricted to the general public? • El 0 ❑ -Is the inspector granted access to all areas for inspection? • El ❑ El Comment Permit#NC0033111 issued April 13, 2018. Expiration Date June, 30, 2023 Bar Screens Yes No NA NE Type of bar screen a Manual ❑ b Mechanical • Are the bars adequately screening debris? • El ❑ ❑ Is the screen free of excessive debris? • El El ❑ Is disposal of screening in compliance? • ❑ ❑ El Is the unit in good condition? III ❑ ❑ El Comment. Static Screen. Screening were Ram Pressed into Dumpster. Aeration Basins Yes No NA NE Mode of operation Ext.Air Type of aeration system Diffused Is the basin free of dead spots? • El El El Are surface aerators and mixers operational? ❑ ❑ M ❑ Are the diffusers operational? MI ❑ El ❑ Is the foam the proper color for the treatment process? • El ❑ ❑ Does the foam cover less than 25%of the basin's surface? U ❑ 0 El Is the DO level acceptable? ❑ II ❑ ❑ Is the DO level acceptable?(1 0 to 3 0 mg/I) ❑ MI ❑ El Comment: The DO#1 31 ppm#2 50 ppm Settability 760 according to new ORC Mathew Golden. Effluent looks good Operations& Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • El ❑ El Page# 3 Permit: NC0033111 Owner-Facility: Fairfield Harbour S/D VNNTP Inspection Date: 02/13/2019 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Does the facility analyze process control parameters,for ex MLSS, MCRT, Settleable • El El El Solids, pH, DO, Sludge Judge, and other that are applicable? Comment. Hurricane Florence caused a lot of damage to the WWTP .The facility is still in clean up mode and repairs. Carolina Water Services has done an amazing lob restoring and replacing the infrustructure Pumps-RAS-WAS Yes No NA NE Are pumps in place? • El El ❑ Are pumps operational? • ❑ ❑ El Are there adequate spare parts and supplies on site? • El ❑ El Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? • El El El Is the site free of excessive buildup of solids in center well of circular clarifier? El I ❑ El Are weirs level? ❑ ■ El ❑ Is the site free of weir blockage? • El El ❑ Is the site free of evidence of short-circuiting? El I El ❑ Is scum removal adequate? • El El El Is the site free of excessive floating sludge? I ❑ El El Is the drive unit operational? • El El El Is the return rate acceptable(low turbulence)? • El El El Is the overflow clear of excessive solids/pin floc? • ❑ El ❑ Is the sludge blanket level acceptable?(Approximately%of the sidewall depth) El • El El Comment Some pin floc but not excessive Sludge blanket was approximately 8 5 Feet in 14 foot clarifier.They recently changed ORC and plans are to reduce solids. Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? • El El El Are UV bulbs clean? • El El El Is UV intensity adequate? • El El El Is transmittance at or above designed level? • El El El Is there a backup system on site? • El El El Is effluent clear and free of solids? • El ❑ El Comment: Page# 4 Permit: NC0033111 Owner-Facility: Fairfield Harbour S/D WWfP Inspection Date: 02/13/2019 Inspection Type: Compliance Evaluation Disinfection - UV Yes No NA NE De-chlorination Yes No NA NE Type of system? Liquid Is the feed ratio proportidnal to chlorine amount(1 to 1)? ❑ ❑ ❑ • Is storage appropnate for cylinders? ❑ 0 ❑ • #Is de-chlorination substance stored away from chlorine containers? El ❑ 0 • Comment: Liquid Bleach is the back-up system to the UV system UV operational If the Back-up system chlorine is used, they use Sodium Bisulfate to dechlorinate. Are the tablets the proper size and type? ❑ 0 El • Are tablet de-chlorinators operational? ❑ ❑ ❑ • Number of tubes in use? Comment Aerobic Digester Yes No NA NE Is the capacity adequate? • 0 ❑ ❑ Is the mixing adequate'? • ❑ El ❑ Is the site free of excessive foaming in the tank'? III ❑ El ❑ #Is the odor acceptable'? • ❑ ❑ El #Is tankage available for properly waste sludge'? • ❑ ❑ ❑ Comment: The Digester sludge was thick. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? • El 0 El Are the receiving water free of foam other than trace amounts and other debris'? • ❑ El El If effluent (diffuser pipes are required) are they operating properly'? El ❑ IN ❑ Comment. Effluent Pipe looked good and appeared not to be much damage if any from Hurricane Florence Carolina Water Services inspected Effluent line as soon as waters receeded. Flow Measurement-Effluent Yes No NA NE #Is flow meter used for reporting'? IS ❑ ❑ ❑ Is flow meter calibrated annually'? • ❑ El El Is the flow meter operational'? • ❑ ❑ ❑ (If units are separated)Does the chart recorder match the flow meter'? ❑ • ❑ ❑ Page# 5 f f Permit NC0033111 Owner-Facility: Fairfield Harbour S/D wwTP Inspection Date: 02/13/2019 Inspection Type: Compliance Evaluation Flow Measurement-Effluent Yes No NA NE Comment: Flow meter calibrated 11 /1/18 Delta Systems. ( Ultra Flow Transmitter) Chart Recorder not operational. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit'? • ❑ 0 ❑ Is all required information readily available, complete and current'? E ❑ 0 ❑ Are all records maintained for 3 years(lab reg. required 5 years)? • ❑ ❑ 0 Are analytical results consistent with data reported on DMRs? • 0 ❑ ❑ Is the chain-of-custody complete? • ❑ ❑ ❑ Dates,times and location of sampling ❑ Name of individual performing the sampling ❑ Results of analysis and calibration ❑ Dates of analysis ❑ Name of person performing analyses ❑ Transported COCs 0 Are DMRs complete do they include all permit parameters? • ❑ 0 ❑ Has the facility submitted its annual compliance report to users and DWQ? 11 0 0 ❑ (If the facility is=or>5 MGD permitted flow)Do they operate 24/7 with a certified operator ❑ ❑ U ❑ on each shift? Is the ORC visitation log available and current? • 0 ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? • 0 0 0 Is the backup operator certified at one grade less or greater than the facility classification? • ❑ 0 0 Is a copy of the current NPDES permit available on site? • 0 ❑ ❑ Facility has copy of previous year's Annual Report on file for review? • 0 ❑ ❑ Comment: The WWTP was flooded and file cabinet with records were lost. Records were avaiible on computer off site.The eDMRs for July, September and October 2018 were reviewed and found no discrepancies. There were some eDMRs on site during inspection.WWTP still in recovery mode. New ORC Mathew Golden Standby Power Yes No NA NE Is automatically activated standby power available? • 0 0 ❑ Is the generator tested by interrupting primary power source'? ❑ • 0 0 Is the generator tested under load'? ❑ IN ❑ ❑ Was generator tested&operational during the inspection? • ❑ 0 0 Do the generator(s)have adequate capacity to operate the entire wastewater site? • 0 ❑ 0 Page# 6 Permit: NC0033111 Owner-Facility: Fairfield Harbour S/D WWTP Inspection Date• 02/13/2019 Inspection Type: Compliance Evaluation Standby Power Yes No NA NE Is there an emergency agreement with a fuel vendor for extended run on back-up power? • ❑ ❑ ❑ Is the generator fuel level monitored? • ❑ 0 ❑ Comment: Generator was serviced 8/29/18. Carolina Water Service has portable tanks and vendor for fuel. The WWTP has a 1000 and 500 gallon supply tank on site Generator is connected to 1000 gallon Tank Disinfection-Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? • ❑ 0 0 (Sodium Hypochlorite)Is pump feed system operational? • ❑ 0 ❑ Is bulk storage tank containment area adequate?(free of leaks/open drains) • ❑ ❑ 0 Is the level of chlorine residual acceptable? ❑ ❑ • ❑ Is the contact chamber free of growth, or sludge buildup? • 0 0 ❑ Is there chlorine residual prior to de-chlorination? 0 ❑ II ❑ Comment. Chlorine is a back-up system to UV system. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? • ❑ ❑ ❑ Are all other parameters(excluding field parameters)performed by a certified lab? • ❑ ❑ El #Is the facility using a contract lab? MIDEI ❑ #Is proper temperature set for sample storage(kept at less than or equal to 6 0 degrees • El ❑ El Celsius)? Incubator(Fecal Coliform)set to 44.5 degrees Celsius+/-0 2 degrees? ❑ ❑ • ❑ Incubator(BOD)set to 20 0 degrees Celsius+/-1 0 degrees? ❑ CIE ❑ Comment The Facility uses Environment 1, Inc and Carolina Water Service Eastern Region is field certified pH, C12 Residual and solids Certificate#5162. The pH buffer expires September 2019 Effluent Sampler is flow proportional Thermometer was not working but unit was cooling. ORC stated they would get thermometer replaced. Page# 7